HomeMy WebLinkAboutTHE SUMMIT ON COLLEGE PARKING GARAGE - MJA/FDP - FDP130056 - SUBMITTAL DOCUMENTS - ROUND 2 - ARCHITECTURAL DETAILSNORTH
UP
UP
UP
BIKE STORAGE
85.67
90.92
83.08
83.75
83.16
80.81 84.00
80.89
83.08
82.50
(G) (G)
(G)
(G)
83.79
84.35
83.70 84.34 84.90
85.15 85.15
85.15
84.85
85.50
85.67
85.83
89.92 87.30 84.67
90.92
90.92
90.92 90.92 88.30 85.67
WASH
WASH WASH WASH
WASH
WASH
WASH
WASH
P.C.C. STITCH
WALL PANEL
P.C.C. LITE
WALL PANEL
ELEVATOR
MACHINE ROOM
104
ELECTRICAL
ROOM
106
WATER ROOM
107
P.C.C. COLUMN, TYPICAL
P.C.C. WALL PANEL
P.C.C. WALL PANEL
METAL GRILLE
BETWEEN STITCH
WALL, TYPICAL AT
RAMP
METAL GRILLE
BETWEEN STITCH
WALL, TYPICAL AT
RAMP
CONCRETE
NORTH
UP
UP
UP
284
Level Compact
1
2
3
P1
Standard HC
Total
Total
80
97
97
274
97
9
36 8 34
111
106
314
14
13 4
NORTH
A S S O C I A T E S
Fort Collins, Colorado
Parking Garage
The Summit on College
LEVEL 1
STRIPING &
SIGNAGE PLAN
A801
NORTH
UP
DN
UP
DN
UP
DN
NORTH
A S S O C I A T E S
Fort Collins, Colorado
Parking Garage
The Summit on College
LEVEL 2
STRIPING &
SIGNAGE PLAN
A802
NORTH
UP
DN
DN
DN
NORTH
A S S O C I A T E S
Fort Collins, Colorado
Parking Garage
The Summit on College
LEVEL 3
STRIPING &
SIGNAGE PLAN
A803
WHEELSTOP, TYPICAL
CHAIN LINK FENCE
GATE W/ MANUAL
CODED LOCK
WALKWAY SEE
CIVIL DRAWINGS
CHAIN LINK FENCE
BETWEEN STITCH
WALL
CHAIN LINK FENCE
W/ POST AT 10'-0"
O.C.EXTEND POST
FROM GRADE TO
BOTTOM OF SLAB OF
LEVEL 2
WALKWAY SEE
CIVIL DRAWINGS
BIKE AISLE
WASH
BIKE RACKS
C.I.P. WALL BELOW
C.I.P. WALL BELOW
WEST STAIR
103
EAST STAIR
102
105
EXISTING CAR
CATCHER
BOLLARDS AND
CHAIN BELOW NEW
STRUCTURE, SEE
NOTE 14
EXISTING CAR
CATCHER
BOLLARDS AND
CHAIN, SEE NOTE 14
(G)
PLAN NOTES
1. DENOTES NOMINAL SPOT ELEVATION IN BUILDING
DATUM (NGVD29) OF TOP OF STRUCTURAL SLAB EXCLUSIVE OF
ALL CANTS, CURBS, WASHES AND FLOWLINES.
2. BUILDING DATUM +/- 0'-0" EQUALS C.C.D. +XX'-XX".
3. UNLESS NOTED OTHERWISE, TOP OF UPTURNED BEAMS AND
EXTERIOR CRASH WALLS SHALL BE 3'-8" ABOVE NOMINAL SPOT
ELEVATIONS INDICATED.
4. PROVIDE 1/2" PRE-MOLDED JOINT FILLER AT SLAB TO WALL
JOINT, U.N.O.
5. ALL JOINTS AND PENETRATIONS IN FIRE RATED ASSEMBLIES TO
BE COMPATIBLE SYSTEMS WITH EQUAL OR GREATER FIRE
RATINGS.
6. ALL PARKING AREA SLAB SLOPES TO DRAINS MIN. 1/8" PER
FOOT U.N.O.. POSITIVE DRAINAGE IS REQUIRED TO ALL FLOOR
DRAINS AND SLOPED AWAY FROM ANY DOORWAYS AND NO
STANDING WATER SHALL BE ALLOWED AT ANY LOCATIONS.
7. WASHES OVER INVERTED TEE BEAMS SHALL BE 1" OR AS
REQUIRED TO MEET COVER REQUIREMENTS. SLOPE SHALL
NOT EXCEED 5% UNLESS SHOWN OTHERWISE ORAPPROVED BY
THE ARCHITECT.
8. ALL JOINTS BETWEEN WASHES AND PC CONCRETE WILL BE
TOOLED AND CAULKED. ALL JOINTS OVER TEE TO TEE
CONNECTIONS WILL BE TOOLED AND CAULKED. MINIMUM
SEALANT WIDTH AT JOINT TO BE 1/2" (TYPICAL).
9. NO PARKING AREA SLAB SLOPES TO EXCEED 2.08% AT
ACCESSIBLE PARKING STALLS AND ACCESS ISLES. (INCLUSIVE
OF ALL CONSTRUCTION TOLERANCES) .
10. ALL PARKING AREAS TO RECEIVE BROOM FINISH PER SPEC.
J033000, U.N.O.
11. FOR STRIPING LAYOUT SEE SHEET A801 THRU A803
12. (G) DENOTES EXTERIOR GRADE ELEVATION.
13. CONTRACTOR SHALL VERIFY A CLEARANCE OF 7'-4" MIN. AND
7'-6" INTENDED FROM TOP OF TOPPING SLAB TO BOTTOM OF
PRECAST AT ALL LOCATIONS IN THE GARAGE.
XX.XX
XX.XX
14. EXISTING CAR CATCHER TO REMAIN UNLESS BOLLARDS OR
FOUNDATIONS INTERFERE WITH NEW GARAGE STRUCTURE OR
NEW FOUNDATIONS. CONTRACTOR TO VERIFY BEFORE
CONSTRUCTION, AND REMOVE WHERE REQUIRED.
A S S O C I A T E S
Fort Collins, Colorado
Parking Garage
The Summit on College
LEVEL 1
FLOOR PLAN
A101