Loading...
HomeMy WebLinkAboutREGISTRY RIDGE SEVENTH FILING, REPLAT OF FILINGS TWO & FOUR - PDP - PDP140020 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSPRELIMINARY UTILITY PLANS FOR REGISTRY RIDGE SEVENTH FILING BEING A REPLAT OF MULTIPLE PARCELS OF TRACT B, INCLUSIVE OF BUILDING ENVELOPE 13 AND BUILDING ENVELOPE 14, AND A PORTION OF TRACT A, INCLUSIVE OF BUILDING ENVELOPE 1, BUILDING ENVELOPE 6 AND BUILDING ENVELOPE 7, OF THE REGISTRY RIDGE P.U.D., SECOND AND REGISTRY RIDGE FOURTH FILING, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO NOVEMBER 2014 THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO STANDARDS AND STATUTES, RESPECTIVELY; AND THAT I AM FULLY RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN, REVISIONS, AND RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS. KEVIN BRAZELTON, PE #38837 DATE SCALE: 1"=400' CERTIFICATION STATEMENT DISCLAIMER STATEMENT VICINITY MAP OWNER / DEVELOPER RC VENTURES, LLC 10221 PRESTWICK TRAIL LONE TREE, CO 80124 CONTACT: 303-587-1966 PHONE: BOB QUINETTE CIVIL ENGINEER UNITED CIVIL DESIGN GROUP, LLC 1501 ACADEMY CT., STE 203 FORT COLLINS, CO 80524 PHONE: 970-530-4044 CONTACT: KEVIN BRAZELTON SURVEYOR KING SURVEYORS, INC. 650 GARDEN DRIVE WINDSOR, CO 80550 PHONE: 970-686-5011 CONTACT: LARRY PEPEK PROJECT TEAM PROJECT COORDINATES VERTICAL DATUM: PROJECT VERTICAL DATUM IS NAVD 88. CONVERSION FROM CITY OF FORT COLLINS-NGVD 1929 DATUM UNADJUSTED TO NAVD 88 DATUM IS AS FOLLOWS: NAVD 88 = NGVD 29 UNADJUSTED + 3.18' BENCHMARK #1: CITY OF FORT COLLINS 10-13 SOUTHEAST CORNER OF SHIELDS ST. AND TRILBY ROAD. , ON A CONCRETE TRAFFIC SIGNAL BASE. ELEVATION=5063.75 (CITY OF FORT COLLINS-NGVD 1929 DATUM UNADJUSTED) ELEVATION=5066.93 (NAVD 88 DATUM) BENCHMARK #2: CITY OF FORT COLLINS 45-01 PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING TRAFFIC SIGNING AND PAVEMENT MARKING CONSTRUCTION NOTES (CONTINUED) 12. The developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period, the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S standards. All signage and striping shall fall under the requirements of the two year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. STANDARD EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize windblown sediment. The developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (striping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPS are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the city/county. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: A. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. B. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. C. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the developer shall be responsible for the cleanup and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The storm water volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the city/county or Homeowners Association (HOA). 13. City ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and Being a Replat Of Multiple Parcels Of Tract B, Inclusive Of Building Envelope 13 And Building Envelope 14, And A Portion of Tract A, Inclusive Of Building Envelope 1, Building Envelope 6 And Building Envelope 7, Of The Registry Ridge P.U. D., Second Filing And Registry Ridge Fourth Filing City Of Fort Collins, County Of Larimer, State Of Colorado VICINITY MAP ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ³ ´ ³ ´ KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 1 LAND USE TABLE LOTS (74) 7.663 ACRES 65% OUTLOTS (3) 2.285 ACRES 19% TRACTS (4) 0.892 ACRES 8% RIGHT OF WAY 0.991 ACRES 8% TOTAL 11.831 ACRES 100% R:\2014615\DWG\2014615SUB.dwg, 11/20/2014 11:13:34 AM TRACT A TRACT B TRACT C OUTLOT A OUTLOT B OUTLOT C 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 6 6 6 6 6 TRACT A 5,247 SQ.FT. 0.120 ACRES OUTLOT A 17,690 SQ.FT. 0.406 ACRES LOT 1 3,077 SQ.FT. LOT 2 3,320 SQ.FT. LOT 3 3,545 SQ.FT. LOT 4 3,692 SQ.FT. LOT 5 3,750 SQ.FT. LOT 6 3,750 SQ.FT. LOT 1 5,750 SQ.FT. LOT 2 4,250 SQ.FT. LOT 3 3,750 SQ.FT. LOT 4 3,750 SQ.FT. LOT 1 3,506 SQ.FT. BLOCK 1 BLOCK 2 OUTLOT A 17,690 SQ.FT. 0.406 ACRES LEGEND OUTLOT C 67,261 SQ.FT. 1.544 ACRES LOT 10 4,790 SQ.FT. LOT 4 6,927 SQ.FT. LOT 5 7,358 SQ.FT. LOT 6 7,414 SQ.FT. LOT 7 7,138 SQ.FT. LOT 8 7,113 SQ.FT. LOT 9 5,744 SQ.FT. LOT 10 6,291 SQ.FT. BLOCK 10 KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 3 SEE SHEET 4 OF 5 SEE SHEET 4 OF 5 TRACT B 15,890 SQ.FT. 0.365 ACRES OUTLOT B 14,610 SQ.FT. 0.335 ACRES 4,250 SQ.FT. LOT 1 3,506 SQ.FT. LOT 2 3,500 SQ.FT. LOT 6 3,188 SQ.FT. LOT 5 3,187 SQ.FT. LOT 4 3,188 SQ.FT. LOT 3 4,037 SQ.FT. LOT 1 3,990 SQ.FT. LOT 2 4,077 SQ.FT. LOT 1 3,913 SQ.FT. LOT 2 3,802 SQ.FT. LOT 1 3,182 SQ.FT. LOT 2 3,187 SQ.FT. LOT 3 3,187 SQ.FT. LOT 4 3,187 SQ.FT. LOT 5 3,187 SQ.FT. LOT 6 3,187 SQ.FT. LOT 7 3,187 SQ.FT. LOT 8 3,187 SQ.FT. LOT 9 3,187 SQ.FT. LOT 10 3,391 SQ.FT. BLOCK 3 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 11 BLOCK 10 TRACT B 15,890 SQ.FT. 0.365 ACRES OUTLOT B 14,610 SQ.FT. 0.335 ACRES OUTLOT A 17,690 SQ.FT. TRACT C 10,023 SQ.FT. 0.230 ACRES TRACT D 7,723 SQ.FT. 0.177 ACRES LOT 1 3,921 SQ.FT. LOT 2 3,865 SQ.FT. LOT 3 4,037 SQ.FT. LOT 4 4,117 SQ.FT. LOT 5 4,125 SQ.FT. LOT 6 4,125 SQ.FT. LOT 7 4,125 SQ.FT. LOT 8 4,489 SQ.FT. LOT 1 4,632 SQ.FT. LOT 2 4,125 SQ.FT. LOT 3 4,125 SQ.FT. LOT 4 4,125 SQ.FT. LOT 5 4,125 SQ.FT. LOT 6 4,125 SQ.FT. LOT 7 4,125 SQ.FT. LOT 8 4,125 SQ.FT. LOT 9 4,125 SQ.FT. LOT 10 4,790 SQ.FT. LOT 1 5,244 SQ.FT. LOT 2 3,956 SQ.FT. LOT 3 4,163 SQ.FT. LOT 4 4,172 SQ.FT. LOT 5 4,172 SQ.FT. LOT 6 4,163 SQ.FT. LOT 7 3,954 SQ.FT. LOT 8 5,219 SQ.FT. LOT 1 5,344 SQ.FT. LOT 2 PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING EXISTING CONDITIONS & REMOVALS - NORTH C100 N/A 40' 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, PAVEMENT, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 5. EXISTING WATER AND SEWER SERVICES AS SHOWN ON THIS DRAWING TO BE REMOVED SHALL BE REMOVED TO THE MAIN PER FORT COLLINS-LOVELAND WATER DISTRICT AND SOUTH FORT PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING EXISTING CONDITIONS & REMOVALS - SOUTH C101 N/A 40' 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, PAVEMENT, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 5. EXISTING WATER AND SEWER SERVICES AS SHOWN ON THIS DRAWING TO BE REMOVED SHALL BE REMOVED TO THE MAIN PER FORT COLLINS-LOVELAND WATER DISTRICT AND SOUTH FORT PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING HORIZONTAL CONTROL PLAN NORTH C200 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' 1. ALL DIMENSIONS AND LINE AND CURVE INFORMATION ARE MEASURED TO CURB FLOW LINE OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 2. CONTRACTOR SHALL REFER TO AND COORDINATE WITH THE APPROVED LANDSCAPE DRAWINGS FOR ALL LANDSCAPE AND SITE FEATURES SUCH AS LANDSCAPE WALLS, SEEDING/SOD, LANDSCAPE ROCK AND MULCH, ETC. 3. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 4. CONCRETE SIDEWALKS ADJACENT TO PUBLIC RIGHT-OF-WAY SHALL BE 6-INCH MINIMUM THICKNESS OR AS REQUIRED PER RECOMMENDATIONS FROM THE GEOTECHNICAL ENGINEER TO SUPPORT A 40-TON VEHICLE. 5. ALL HANDICAP RAMPS (PRIVATE AND PUBLIC) SHALL BE INSTALLED WITH TRUNCATED DOME WARNING DETECTION SYSTEMS PER LARIMER COUNTY URBAN AREA STREET STANDARD DETAILS. 6. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING HORIZONTAL CONTROL PLAN SOUTH C201 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' 1. ALL DIMENSIONS AND LINE AND CURVE INFORMATION ARE MEASURED TO CURB FLOW LINE OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 2. CONTRACTOR SHALL REFER TO AND COORDINATE WITH THE APPROVED LANDSCAPE DRAWINGS FOR ALL LANDSCAPE AND SITE FEATURES SUCH AS LANDSCAPE WALLS, SEEDING/SOD, LANDSCAPE ROCK AND MULCH, ETC. 3. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 4. CONCRETE SIDEWALKS ADJACENT TO PUBLIC RIGHT-OF-WAY SHALL BE 6-INCH MINIMUM THICKNESS OR AS REQUIRED PER RECOMMENDATIONS FROM THE GEOTECHNICAL ENGINEER TO SUPPORT A 40-TON VEHICLE. 5. ALL HANDICAP RAMPS (PRIVATE AND PUBLIC) SHALL BE INSTALLED WITH TRUNCATED DOME WARNING DETECTION SYSTEMS PER LARIMER COUNTY URBAN AREA STREET STANDARD DETAILS. 6. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING UTILITY PLAN NORTH C300 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE STORM END SECTION MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. GAS LINE ELECTRIC LINE LIGHT POLE S. SHIELDS STREET BON HOMME RICHARD DRIVE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING UTILITY PLAN SOUTH C301 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE STORM END SECTION MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. GAS LINE ELECTRIC LINE LIGHT POLE S. SHIELDS STREET BON HOMME RICHARD DRIVE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING 0 30' 60' SCALE: 1" = 30' 15' SANITARY SEWER PLAN & PROFILE LINE A & LINE B C400 3' 30' SANITARY SEWER LINE A 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 5. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 6. SANITARY SEWER SERVICES ARE 4" IN SIZE UNLESS NOTED OTHERWISE. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET STORM DRAIN M.H. WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING 0 30' 60' SCALE: 1" = 30' 15' SANITARY SEWER PLAN & PROFILE LINE C C401 3' 30' SANITARY SEWER LINE C 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 5. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 6. SANITARY SEWER SERVICES ARE 4" IN SIZE UNLESS NOTED OTHERWISE. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET STORM DRAIN M.H. WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING 0 30' 60' SCALE: 1" = 30' 15' SANITARY SEWER PLAN & PROFILE LINE C6 C402 3' 30' SANITARY SEWER LINE C6 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 5. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 6. SANITARY SEWER SERVICES ARE 4" IN SIZE UNLESS NOTED OTHERWISE. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET STORM DRAIN M.H. WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING OVERLOT GRADING & EROSION CONTROL PLAN NORTH C600 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR STORM SEWER STORM INLET NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. VEGETATIVE SWALES, PERMEABLE PAVERS AND THE POROUS LANDSCAPE DETENTION SHALL BE MAINTAINED BY THE PROPERTY OWNER OR HOA AND FOLLOW APPLICABLE STANDARD OPERATING PROCEDURES AS SHOWN IN DRAINAGE REPORT FOR REGISTRY RIDGE SEVENTH FILING. 3. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE, EDGE OF WALK, OR LOT CORNER UNLESS OTHERWISE NOTED. 4. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS. SILT FENCE VEHICLE TRACKING CONTROL PAD RIPRAP WATTLE DIKE CONCRETE WASHOUT AREA - FINAL LOCATION TO BE DETERMINED PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING OVERLOT GRADING & EROSION CONTROL PLAN SOUTH C601 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR STORM SEWER STORM INLET NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. VEGETATIVE SWALES, PERMEABLE PAVERS AND THE POROUS LANDSCAPE DETENTION SHALL BE MAINTAINED BY THE PROPERTY OWNER OR HOA AND FOLLOW APPLICABLE STANDARD OPERATING PROCEDURES AS SHOWN IN DRAINAGE REPORT FOR REGISTRY RIDGE SEVENTH FILING. 3. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE, EDGE OF WALK, OR LOT CORNER UNLESS OTHERWISE NOTED. 4. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS. SILT FENCE VEHICLE TRACKING CONTROL PAD RIPRAP WATTLE DIKE CONCRETE WASHOUT AREA - FINAL LOCATION TO BE DETERMINED BY CONTRACTOR SLOPE PROTECTION (SEE EROSION PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING LEGEND NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. THE PROPOSED CONSTRUCTION WILL BE IN CLOSE PROXIMITY TO SEVERAL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY PROVIDERS PRIOR TO AND DURING CONSTRUCTION TO MINIMIZE SERVICE INTERRUPTIONS TO SURROUNDING BUILDINGS OR PROPERTIES. 3. PAVEMENT SECTION INFORMATION FOR ALL PAVEMENT WITHIN PUBLIC RIGHT-OF-WAY SHALL BE APPROVED BY THE CITY OF LOVELAND WITH A FINAL PAVEMENT DESIGN REPORT DURING CONSTRUCTION PER LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS) SECTION 10.2. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE PROPOSED CURB & GUTTER S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING DRAINAGE PLAN C800 N/A CHECKED BY: 60' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 00 60' 120' SCALE: 1" = 60' 30' 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. VEGETATIVE SWALES, PERMEABLE PAVERS AND THE POROUS LANDSCAPE DETENTION SHALL BE MAINTAINED BY THE PROPERTY OWNER OR HOA AND FOLLOW APPLICABLE STANDARD OPERATING PROCEDURES AS SHOWN IN DRAINAGE REPORT FOR REGISTRY RIDGE SEVENTH FILING. LEGEND NOTES D-101 BASIN DESIGNATION BASIN AREA (ACRE) 2 - YR RUNOFF COEFF. 100 - YR RUNOFF COEFF. BASIN BOUNDARY DESIGN POINT FLOW DIRECTION DRAINAGE SUMMARY Basin Design Point Area %I C2 C100 Q2 Q100 (acre) (cfs) (cfs) Proposed Basins -Northeast Site A1 A1 0.17 49% 0.62 0.78 0.30 1.29 A2 A2 0.43 52% 0.64 0.80 0.79 3.45 A3 A3 0.19 54% 0.65 0.81 0.34 1.50 A4 A4 0.63 18% 0.38 0.48 0.68 2.98 Proposed Basins -North Central Site B1 B1 0.14 2% 0.25 0.31 0.10 0.45 B2 B2 0.85 58% 0.68 0.85 1.66 7.24 B3 B3 0.43 50% 0.62 0.77 0.75 3.29 B4 B4 0.84 56% 0.68 0.84 1.44 6.27 Existing Basins -Adjacent to North Central Site 1D 1D 0.51 69% 0.76 0.95 1.09 4.77 1E 1E 0.09 48% 0.62 0.77 0.15 0.67 Proposed Basins -South Site C1 C1 0.62 46% 0.59 0.74 0.75 3.29 C2 C2 0.45 57% 0.67 0.84 0.87 3.78 C3 C3 0.34 59% 0.69 0.86 0.66 2.89 C4 C4 1.14 52% 0.64 0.79 2.07 9.02 C5 C5 0.97 60% 0.69 0.86 1.90 8.31 C6 C6 0.91 33% 0.50 0.62 1.29 5.63 C7 C7 0.31 39% 0.55 0.68 0.35 1.53 C8 C8 0.82 40% 0.55 0.69 1.30 5.66 C9 C9 0.86 36% 0.52 0.65 1.27 5.55 C10 C10 0.71 29% 0.47 0.59 0.95 4.13 C11 C11 0.88 22% 0.41 0.51 1.03 4.47 C12 C12 0.13 2% 0.25 0.31 0.09 0.38 Onsite Total 11.83 43% 0.56 0.70 18.58 81.10 A4 A1 C8 C3 C4 C5 C6 C9 S8 C7 C11 C10 C12 HORNET DRIVE ENTERPRISE DRIVE PRIVATE DRIVE PRIVATE DRIVE NIMITZ DRIVE PRIVATE DRIVE PRIVATE DRIVE PRIVATE DRIVE PROPOSED STORM DRAIN LINE 5 POROUS LANDSCAPE DETENTION PROPOSED STORM DRAIN LINE 1 PROPOSED STORM INLET PROPOSED STORM INLETS PROPOSED STORM INLET POROUS LANDSCAPE DETENTION CURB CUT AND SIDEWALK CHASE CURB CUT AND SIDEWALK CHASE PROPOSED STORM DRAIN LINE 4 CURB CUT AND SIDEWALK CHASE PROPOSED POND OUTLET STRUCTURE CURB CUT AND SIDEWALK CHASE PERMEABLE PAVERS WITH UNDERDRAIN CITY HIGH RISK FLOODWAY PROPOSED STORM DRAIN LINE 2 PROPOSED STORM DRAIN LINE 3 0 50' 100' SCALE: 1" = 50' 25' HORNET DRIVE CENTERLINE STREET PLAN & PROFILE C700 5' 50' HORNET DRIVE CENTERLINE CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 5055 5060 5065 5070 5075 5080 5085 5090 5055 5060 5065 5070 5075 5080 5085 5090 EG= FG= 9+50 EG= FG= 10+00 EG=5076.1 FG=5076.18 10+50 EG=5075.4 FG=5075.24 11+00 EG=5074.4 FG=5074.62 11+50 EG=5074.1 FG=5073.99 12+00 EG=5073.4 FG=5073.37 12+50 EG=5072.1 FG=5072.74 13+00 EG=5072.4 FG=5072.12 13+50 EG=5072.0 FG=5071.54 14+00 EG=5070.7 FG=5071.52 14+50 EG=5071.8 FG=5071.82 15+00 EG=5071.6 FG=5072.12 15+50 EG=5071.1 FG=5072.49 16+00 EG=5072.7 FG=5073.29 16+50 EG=5072.7 FG=5074.16 17+00 EG=5073.3 FG=5074.86 17+50 EG=5073.8 FG=5074.80 18+00 EG=5074.8 FG=5074.04 18+50 EG=5074.1 FG= 19+00 EG= FG= 19+50 PVI STA = 10+48.12 PVI ELEV = 5076.22 PVI STA = 18+79.52 PVI ELEV = 5073.66 PVI STA = 18+71.53 PVI ELEV = 5073.66 110.0' VC HIGH PT EL: 5074.93 HIGH PT STA: 17+71.53 PVI STA: 17+71.53 PVI EL: 5075.41 AD: 3.50 K: 31.43 BVCS: 17+16.53 BVCE: 5074.45 EVCS: 18+26.53 EVCE: 5074.45 20.0' VC LOW PT EL: 5075.22 LOW PT STA: 11+01.55 PVI STA: 10+91.55 PVI EL: 5075.35 AD: 0.75 K: 26.67 BCVS: 10+81.55 BVCE: 5075.55 ECVS: 11+01.55 EVCE: 5075.22 50.0' VC PVI STA: 16+00.59 PVI EL: 5072.42 AD: 1.15 K: 43.48 BCVS: 15+75.59 BVCE: 5072.27 ECVS: 16+25.59 EVCE: 5072.86 65.0' VC LOW PT EL: 5071.44 LOW PT STA: 14+26.35 PVI STA: 14+14.93 PVI EL: 5071.31 AD: 1.85 K: 35.14 BCVS: 13+82.43 BVCE: 5071.71 ECVS: 14+47.43 EVCE: 5071.50 PROPOSED GRADE EXISTING GROUND STA: 14+25.97 INV.= 5067.68' 24" STORM DRAIN 11+00 10+00 9+50 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 19+50 STA: 9+50.00 N: 1421851.49 E: 3112382.34 BEGIN ALIGNMENT STA: 19+49.88 N: 1421846.87 E: 3112823.41 END ALIGNMENT 1ƒ ( ¨ = 9 0 ƒ 12 ' 14 " L = 2 5 9 . 7 7 , R = 16 5. 00 6ƒ ( ¨ = 8 9 ƒ 47 ' 4 6 " L = 2 5 8 . 5 9, R = 1 6 5 . 0 0 6ƒ ( STA: 10+48.12 BEGIN CONSTRUCTION MATCH EXISTING BON HOMME RICHARD DRIVE N: 1421753.37 E: 3112382.34 STA: 18+80.08 END CONSTRUCTION MATCH EXISTING BON HOMME RICHARD DRIVE N: 1421777.07 E: 3112823.41 27.67' EP-EP NIMITZ DRIVE ENTERPRISE DRIVE 53' ROW HORNET DRIVE PRIVATE DRIVE PRIVATE DRIVE 68' ROW 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT REC. NO. 99055752 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 BLOCK 11 BLOCK 12 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 10 LOT 9 LOT 8 OUTLOT C LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 TRACT D LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 CENTERLINE 13.83' EP-EP 13.83' EP-EP NOT TO SCALE 4.5' SW 31" DRIVE-OVER CURB AND GUTTER HORNET DRIVE TYPICAL STREET SECTION 5.58' PKWY 4.5' SW 5.58' PKWY 53' ROW 30' FL-FL 2% MIN. 2% MIN. 2% MIN. 2% MIN. CONTROL NOTE 5) DROP INLET PROTECTION TURF REINFORCEMENT MAT POROUS LANDSCAPE DETENTION ROCK SOCK S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP EROSION CONTROL SEQUENCING EROSION CONTROL NOTES 0 40' 80' SCALE: 1" = 40' 20' 1. THE SITE WILL BE LANDSCAPED TO FINAL STABILIZATION. SEE FINAL LANDSCAPE PLAN FOR DETAILS. 2. REFER TO SHEET C001 FOR STANDARD EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES. 3. EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 4. IN ADDITION TO THE EROSION CONTROL MEASURES SHOWN ON THIS DRAWING, THE CONTRACTOR SHALL COORDINATE WITH, AND UPDATE AS REQUIRED, THE STORMWATER MANAGEMENT PLAN (SWMP) FOR THIS PROJECT. 5. CONTRACTOR TO TERRACE SLOPES USING A "TRACKED" VEHICLE, RUN PERPENDICULAR TO SLOPE TO INHIBIT RILL/GULLEY EROSION, CONTRACTOR MAY USE OTHER WINDROW-TYPE METHODS AS APPROVED BY ENGINEER. TYPICAL ALL SLOPES, REPEAT AS NECESSARY UNTIL LANDSCAPING IS INSTALLED. 6. ANY AREAS USED FOR STOCKPILING AND/OR STAGING SHOULD ALSO HAVE SEDIMENT AND EROSION CONTROL MEASURES AS NECESSARY. THESE AREAS SHOULD BE LOCATED AT LEAST 100' AWAY FROM DRAINAGE WAYS. THE SWMP SHOULD BE UPDATED TO SHOW THESE AREAS AND SEDIMENT AND EROSION CONTROL ITEMS. THE ITEMS MAY INCLUDE BUT ARE NOT LIMITED TO VEHICLE TRACKING CONTROL, SILT FENCE, CONSTRUCTION FENCE, CONCRETE WASHOUT, AND SEDIMENT TRAP. 7. SOIL AMENDMENTS SHALL BE INCORPORATED IN ALL LANDSCAPE AREAS TO A DEPTH OF 6" AT A RATE OF 3 CUBIC YARDS PER 1000 SQUARE FEET OF AREA -OR- 4" OF LOOSE TOPSOIL IMPORTED ONTO THE SITE OVER 4" OF LOOSENED SUBGRADE SOILS. REFER TO CITY OF FORT COLLINS CODE SECTIONS 12-130 THROUGH 12-132. 8. TEMPORARY SEEDING SHALL BE UTILIZED IN THE EVENT THAT A GRADED AREA IS EXPOSED LONGER THAN 30 DAYS. THE SITE SHALL BE SEEDED WITH 100% SMOOTH BROME AT A MINIMUM APPLICATION RATE OF 30 PLS/LBS/ACRE. 9. A COMMERCIAL FERTILIZER WITH THE FOLLOWING SPECS SHALL BE USED: PROJECT: BEST MANAGEMENT PRACTICE ITEM: PRESERVE EXISTING VEGETATION SILT FENCE VEHICLE TRACKING CONTROL STAGING AREAS CONCRETE WASHOUT AREA CURB INLET PROTECTION (RS) SWALE AND SLOPE PROTECTION SIDEWALK CHASE FILTER PHASE OF CONSTRUCTION NIMITZ DRIVE HORNET DRIVE PRIVATE DRIVE PRIVATE DRIVE POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION ENTERPRISE DR. 26' ACCESS, EMERGENCY ACCESS, UTILITY& DRAINAGE EASEMENT 20' ACCESS, UTILITY & DRAINAGE EASEMENT 53' ROW 68' ROW 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT 22.86' UTILITY, DRAINAGE GRADING & LANDSCAPE EASEMENT PRIVATE DRIVE PRIVATE DRIVE BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 BLOCK 11 BLOCK 12 TRACT B LOT 1 LOT 2 OUTLOT B LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 10 LOT 9 LOT 8 OUTLOT C LOT 7 LOT 6 LOT 5 LOT 4 LOT 2 LOT 3 LOT 1 LOT 4 LOT 3 LOT 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 6 LOT 7 LOT 8 LOT 5 LOT 1 LOT 2 LOT 3 LOT 4 TRACT D LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 PERMEABLE PAVERS 6" UNDER DRAIN 18" STORM DRAIN CURB CUT & SIDEWALK CHASE CURB CUT & SIDEWALK CHASE POND OUTLET STRUCTURE 24" STORM DRAIN CITY HIGH RISK FLOODWAY 2' SIDEWALK CHASE 2' SIDEWALK CHASE 2' SIDEWALK CHASE BY CONTRACTOR SLOPE PROTECTION (SEE EROSION CONTROL NOTE 5) DROP INLET PROTECTION TURF REINFORCEMENT MAT POROUS LANDSCAPE DETENTION ROCK SOCK S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP PROJECT: BEST MANAGEMENT PRACTICE ITEM: PRESERVE EXISTING VEGETATION SILT FENCE VEHICLE TRACKING CONTROL STAGING AREAS CONCRETE WASHOUT AREA CURB INLET PROTECTION (RS) SWALE AND SLOPE PROTECTION SIDEWALK CHASE FILTER PHASE OF CONSTRUCTION EROSION CONTROL SEQUENCING EROSION CONTROL NOTES 1. THE SITE WILL BE LANDSCAPED TO FINAL STABILIZATION. SEE FINAL LANDSCAPE PLAN FOR DETAILS. 2. REFER TO SHEET C001 FOR STANDARD EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES. 3. EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 4. IN ADDITION TO THE EROSION CONTROL MEASURES SHOWN ON THIS DRAWING, THE CONTRACTOR SHALL COORDINATE WITH, AND UPDATE AS REQUIRED, THE STORMWATER MANAGEMENT PLAN (SWMP) FOR THIS PROJECT. 5. CONTRACTOR TO TERRACE SLOPES USING A "TRACKED" VEHICLE, RUN PERPENDICULAR TO SLOPE TO INHIBIT RILL/GULLEY EROSION, CONTRACTOR MAY USE OTHER WINDROW-TYPE METHODS AS APPROVED BY ENGINEER. TYPICAL ALL SLOPES, REPEAT AS NECESSARY UNTIL LANDSCAPING IS INSTALLED. 6. ANY AREAS USED FOR STOCKPILING AND/OR STAGING SHOULD ALSO HAVE SEDIMENT AND EROSION CONTROL MEASURES AS NECESSARY. THESE AREAS SHOULD BE LOCATED AT LEAST 100' AWAY FROM DRAINAGE WAYS. THE SWMP SHOULD BE UPDATED TO SHOW THESE AREAS AND SEDIMENT AND EROSION CONTROL ITEMS. THE ITEMS MAY INCLUDE BUT ARE NOT LIMITED TO VEHICLE TRACKING CONTROL, SILT FENCE, CONSTRUCTION FENCE, CONCRETE WASHOUT, AND SEDIMENT TRAP. 7. SOIL AMENDMENTS SHALL BE INCORPORATED IN ALL LANDSCAPE AREAS TO A DEPTH OF 6" AT A RATE OF 3 CUBIC YARDS PER 1000 SQUARE FEET OF AREA -OR- 4" OF LOOSE TOPSOIL IMPORTED ONTO THE SITE OVER 4" OF LOOSENED SUBGRADE SOILS. REFER TO CITY OF FORT COLLINS CODE SECTIONS 12-130 THROUGH 12-132. 8. TEMPORARY SEEDING SHALL BE UTILIZED IN THE EVENT THAT A GRADED AREA IS EXPOSED LONGER THAN 30 DAYS. THE SITE SHALL BE SEEDED WITH 100% SMOOTH BROME AT A MINIMUM APPLICATION RATE OF 30 PLS/LBS/ACRE. 9. A COMMERCIAL FERTILIZER WITH THE FOLLOWING SPECS SHALL BE USED: NIMITZ DRIVE TERPRISE DR. 26' ACCESS, EMERGENCY 68' ROW 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT 22.86' UTILITY, DRAINAGE GRADING & LANDSCAPE EASEMENT 27.42' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT PRIVATE DRIVE PRIVATE DRIVE PRIVATE DRIVE BLOCK 1 BLOCK 2 BLOCK 3 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 11 LOT 1 OUTLOT A LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 TRACT A LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 LOT 6 TRACT B LOT 1 LOT 2 OUTLOT B LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 10 LOT 9 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 2' SIDEWALK CHASE 12" STORM DRAIN 12" STORM DRAIN 2' SIDEWALK CHASE 2' SIDEWALK CHASE 2' SIDEWALK CHASE WATER SERVICE SANITARY SERVICE STORM DRAIN INLET MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. LIGHT POLE S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 5055 5060 5065 5070 5075 5080 5085 5055 5060 5065 5070 5075 5080 5085 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 MH C6 STA 10+00.00 5,0“ INV. IN 5060.19 (W) INV. OUT 5059.99 (S) INV. OUT 5061.49 (E) D = 14.47' MH C6.1(W) STA 6+80.00 5,0“ INV. OUT 5061.63 (E) D = 10.11' 320.00 LF 8" PVC @ 0.45% PROPOSED GRADE EXISTING GROUND STA: 9+89.00 INV.= 5069.51' 8" WATER 375.00 LF 8" PVC @ 0.80% MH C6.1(E) STA 13+75.00 5,0“ INV. IN 5064.49 (W) D = 10.77' WATER SERVICE SANITARY SERVICE STORM DRAIN INLET MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. LIGHT POLE S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 5055 5060 5065 5070 5075 5080 5085 5055 5060 5065 5070 5075 5080 5085 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 MH C6 STA 15+09.72 5,0“ INV. IN 5060.19 (W) INV. OUT 5059.99 (S) INV. OUT 5061.49 (E) D = 14.47' 8" PVC 24.41 LF @ 0.45% MH C5 STA 14+85.30 5,0“ INV. IN 5059.88 (N) INV. OUT 5059.68 (SE) D = 14.55' 87.18 LF 8" PVC @ 0.45% MH C4 STA 13+98.12 5,0“ INV. IN 5059.29 (NW) INV. OUT 5059.09 (SE) D = 14.03' 63.47 LF 8" PVC @ 0.45% MH C3 STA 13+34.65 5,0“ INV. IN 5058.81 (NW) INV. OUT 5058.61 (E) D = 13.70' 80.41 LF 8" PVC @ 0.45% MH C2 STA 12+54.25 5,0“ INV. IN 5058.24 (W) INV. OUT 5058.04 (S) D = 13.40' 190.25 LF 8" PVC @ 0.45% MH C1 STA 10+64.00 5,0“ INV. IN 5057.19 (N) INV. OUT 5056.99 (SE) D = 8.06' EX MH STA 10+00.00 5,0“ INV. IN 5056.70 (NW) EX. INV. IN 5056.50 (W) EX. INV. OUT 5056.50 (E) D = 5.28' 64.00 LF 8" PVC @ 0.45% PROPOSED GRADE EXISTING GROUND STA: 10+73.02 INV.= 5061.57' 6" UNDER DRAIN STA: 12+44.25 INV.= 5066.26' 8" WATER CORE DRILL AND CONNECT TO EXISTING MANHOLE WATER SERVICE SANITARY SERVICE STORM DRAIN INLET MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. LIGHT POLE S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: SANITARY SEWER LINE B 5055 5060 5065 5070 5075 5080 5085 5055 5060 5065 5070 5075 5080 5085 9+75 10+00 10+50 11+00 11+50 12+00 EX MH STA 10+00.00 5,0“ INV. IN 5064.10 (E) EX INV. IN 5062.70 (N) EX INV. OUT 5062.60 (S) D = 13.98' 184.57 LF 8" PVC @ 0.75% MH A1 STA 11+84.57 5,0“ INV. OUT 5065.48 (W) D = 10.57' PROPOSED GRADE EXISTING GROUND CORE DRILL AND CONNECT TO EXISTING MANHOLE 5055 5060 5065 5070 5075 5080 5085 5055 5060 5065 5070 5075 5080 5085 9+75 10+00 10+50 11+00 EX MH STA 10+00.00 5,0“ INV. IN 5065.74 (SE) EX INV. IN 5064.10 (E) EX. INV. IN 5064.00 (SW) EX INV. OUT 5064.00 (N) D = 13.60' 82.00 LF 8" PVC @ 1.00% MH B1 STA 10+82.00 5,0“ INV. OUT 5066.56 (NW) D = 10.84' STA: 10+22.99 INV.= 5073.02' PROP. 12" STORM DRAIN PROPOSED GRADE EXISTING GROUND CORE DRILL AND CONNECT TO EXISTING MANHOLE. GROUT FILL THE EXISTING 6" INVERT TO THE EAST ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. WATER SERVICE PROVIDED BY FORT COLLINS-LOVELAND WATER DISTRICT. SANITARY SERVICE PROVIDED BY SOUTH FORT COLLINS SANITATION DISTRICT. SEE THE CONSTRUCTION SPECIFICATIONS. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0'. MAXIMUM COVER SHALL BE 6.0'. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 6. ALL WATER SERVICES REQUIRE METER PIT INSTALLATION. 7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 9. WATER MAINS AND FIRE SERVICES SHALL BE AWWA C-900 PVC. WATER SERVICES SHALL BE 3/4" TYPE K COPPER. 68' ROW NIMITZ DRIVE HORNET DRIVE ENTERPRISE DRIVE PRIVATE DRIVE FIRE HYDRANT TO BE RELOCATED TO CURB WET TAP EXISTING 10" WATER MAIN 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT WATER SERVICE (TYP.) SANITARY SERVICE (TYP.) SANITARY LINE A6 (SEE SHEET C401) 20' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT REMOVE EXISTING HYDRANT & CONNECT TO EXISTING 8" MAIN EXISTING FIRE HYDRANT S. SHIELDS STREET EXISTING 36" STORM 22.86' UTILITY & DRAINAGE EASEMENT 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASMENT REC. NO. 99055752 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT EXISTING 8" SANITARY ENTERPRISE DRIVE NIMITZ DRIVE 8" WATER MAIN PROPOSED FIRE HYDRANT SANITARY LINE A (SEE SHEET C401) 30' UTILITY & DRAINAGE EASEMENT 24" STORM DRAIN POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION 24" STORM DRAIN CONNECT TO EXISTING 8" SANITARY SEWER 53' ROW PRIVATE DRIVE 8" WATER MAIN 6" UNDER DRAIN 18" STORM DRAIN PROPOSED FIRE HYDRANT SANITARY LINE A6 (SEE CHEET C402) 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT EXISTING FIRE HYDRANT EXISTING 10" WATER BON HOMME RICHARD DRIVE BON HOMME RICHARD DRIVE BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 BLOCK 11 BLOCK 12 TRACT B LOT 1 LOT 2 OUTLOT B LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 10 LOT 9 LOT 8 OUTLOT C LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 1 LOT 2 LOT 4 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 TRACT D LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. WATER SERVICE PROVIDED BY FORT COLLINS-LOVELAND WATER DISTRICT. SANITARY SERVICE PROVIDED BY SOUTH FORT COLLINS SANITATION DISTRICT. SEE THE CONSTRUCTION SPECIFICATIONS. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0'. MAXIMUM COVER SHALL BE 6.0'. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 6. ALL WATER SERVICES REQUIRE METER PIT INSTALLATION. 7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 9. WATER MAINS AND FIRE SERVICES SHALL BE AWWA C-900 PVC. WATER SERVICES SHALL BE 3/4" TYPE K COPPER. NOTES WET TAP EXISTING 10" WATER MAIN 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT EXISTING 10" WATER 68' ROW FIRE HYDRANT TO BE RELOCATED TO CURB 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT EXISTING FIRE HYDRANT REMOVE EXISTING HYDRANT & CONNECT TO EXISTING 8" MAIN ENTERPRISE DRIVE NIMITZ DRIVE BON HOMME RICHARD DRIVE WET TAP EXISTING 8" WATER MAIN 8" WATER MAIN PROPOSED FIRE HYDRANT 12" STORM DRAIN SANITARY LINE A (SEE SHEET C400) 30' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT CONNECT TO EXISTING MH EXISTING 8" SANITARY CONNECT TO EXISTING MH 20' DRAINAGE EASEMENT 30' UTILITY EASEMENT SANITARY LINE B (SEE SHEET C400) 66' ROW EXISTING 8" SANITARY EXISTING 30" STORM DRAIN WATER SERVICE (TYP.) SANITARY SERVICE (TYP.) 8" WATER MAIN 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT WET TAP EXISTING 8" WATER MAIN 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT S. SHIELDS STREET BLOCK 1 BLOCK 2 BLOCK 3 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 11 LOT 1 OUTLOT A LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 TRACT A LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 LOT 6 TRACT B LOT 1 LOT 2 OUTLOT B LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 10 LOT 9 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 CONNECT TO EXISTING SANITARY SEWER SERVICE (TYP.) CONNECT TO EXISTING SANITARY SEWER SERVICE (TYP.) 7. 2-INCH MILL AND OVERLAY OF ENTERPRISE DRIVE SHALL BE COMPLETED ONCE ALL STREET CUTS FOR UTILITY AND CURB AND GUTTER CONSTRUCTION ARE COMPLETE. 8. BON HOMME RICHARD DRIVE SHALL BE RECONSTRUCTED ONCE ALL STREET CUTS FOR UTILITY CONSTRUCTION ARE COMPLETE. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES CONCRETE PAVEMENT OR SIDEWALK ASPHALT PAVEMENT CURB & GUTTER CURB & GUTTER TRANSITION T PERMEABLE PAVERS S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP MILL & OVERLAY SAWCUT STREET RECONSTRUCTION 68' ROW 53' ROW 15' UTILITY, DRAINAGE, GRADING AND LANDSCAPE EASEMENT R=25' R=25' 9' UTILITY EASEMENT 9' UTILITY EASEMENT 2' SIDEWALK CHASE TYPE I DRIVEWAY APPROACH DRIVE OVER CURB & GUTTER 4.5' SIDEWALK 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER DISTRICT EASEMENT 22.86' UTILITY & DRAINAGE EASEMENT PROPERTY BOUNDARY (TYP.) 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER DISTRICT EASEMENT 30' UTILITY & DRAINAGE EASEMENT POND OUTLET STUCTURE STORM INLET STORM INLET 27.67' EP-EP DRIVE OVER CURB & GUTTER 20' ACCESS, EMERGENCY ACCESS, RIBBON CURB UTILITY & DRAINAGE EASEMENT 16.92' EP-EP 2' SIDEWALK CHASE TYPE I DRIVEWAY APPROACH TYPE I DRIVEWAY APPROACH R=25' RIBBON CURB 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT 8' UTILITY EASEMENT R=25' BOC R=25' BOC PERMEABLE PAVERS DRIVE OVER CURB & GUTTER STORM INLET NIMITZ DRIVE HORNET DRIVE ENTERPRISE DRIVE PRIVATE DRIVE S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE PRIVATE DRIVE PRIVATE DRIVE PRIVATE DRIVE POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION CITY HIGH RISK FLOODWAY BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 BLOCK 11 BLOCK 12 TRACT B LOT 1 LOT 2 OUTLOT B LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 10 LOT 9 LOT 8 OUTLOT C LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 TRACT D LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 7. 2-INCH MILL AND OVERLAY OF ENTERPRISE DRIVE SHALL BE COMPLETED ONCE ALL STREET CUTS FOR UTILITY AND CURB AND GUTTER CONSTRUCTION ARE COMPLETE. 8. BON HOMME RICHARD DRIVE SHALL BE RECONSTRUCTED ONCE ALL STREET CUTS FOR UTILITY CONSTRUCTION ARE COMPLETE. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES CONCRETE PAVEMENT OR SIDEWALK ASPHALT PAVEMENT CURB & GUTTER CURB & GUTTER TRANSITION T PERMEABLE PAVERS S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP MILL & OVERLAY SAWCUT STREET RECONSTRUCTION 68' ROW S. SHIELDS STREET ENTERPRISE DRIVE NIMITZ DRIVE BON HOMME RICHARD DRIVE ENTERPRISE DRIVE PRIVATE DRIVE PRIVATE DRIVE 22.25' PRIVATE DRIVE EP-EP TYPE I DRIVEWAY APPROACH DRIVE-OVER CURB & GUTTER (TYP.) 2' CURB CUT & SIDEWALK CHASE 30' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT STORM INLET PROPERTY BOUNDARY (TYP.) 20' EXISTING DRAINAGE EASEMENT 30' EXISTING SANITARY EASEMENT 20' EXISTING DRAINAGE EASEMENT PROPERTY BOUNDARY (TYP.) STORM INLET 8' UTILITY EASEMENT 2" MILL & OVERLAY (SEE NOTE 7) APPROXIMATE SAWCUT AND PATCH FOR UTILITY CONSTRUCTION (TYP.) RECONSTRUCT EXISTING ENTRANCE WITH UTILITY CONSTRUCTION 2' CURB CUT 21.92' EP-EP 26' ACCESS, EMERGENCY ACCESS, UTILITY & R=25' DRAINAGE EASEMENT R=15' RIBBON CURB (TYP.) 18.33' EP-EP 2' CURB CUT & SIDEWALK CHASE 2' CURB CUT & SIDEWALK CHASE 9' UTILITY EASEMENT DRIVE OVER CURB & GUTTER (TYP.) 10.83' EP-EP 10.83' EP-EP 2' CURB CUT & SIDEWALK CHASE CONNECT TO & MATCH EXISTING PAVEMENT EXISTING DRIVE 15' UTILITY, DRAINAGE, GRADING AND LANDSCAPE EASEMENT ROADWAY RECONSTRUCTION (SEE NOTE 8) BON HOMME RICHARD DRIVE 36' WIDE DUAL DRIVEWAY APPROACH 36' WIDE DUAL DRIVEWAY APPROACH 36' WIDE DUAL DRIVEWAY APPROACH 36' WIDE DUAL DRIVEWAY APPROACH 66' ROW BLOCK 1 BLOCK 2 BLOCK 3 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 11 LOT 1 OUTLOT A LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 TRACT A LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 LOT 2 LOT 6 LOT 5 LOT 4 LOT 3 TRACT B LOT 1 LOT 2 OUTLOT B LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 10 LOT 9 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 COLLINS SANITATION DISTRICT STANDARDS (LATEST EDITION.) LEGEND NOTES LOT LINES / R.O.W. EASEMENT LINES CENTERLINE MAPPING CURB AND GUTTER INTERMEDIATE CONTOUR INDEX CONTOUR EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. WATER VALVE FIRE HYDRANT LIGHT POLE WATER / SANITARY PLUG WATER METER WATER VAULT FENCE PROPERTY BOUNDARY S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' REMOVE EXISTING CONCRETE OR SIDEWALK REMOVE EXISTING CURB AND GUTTER SAWCUT LINE REMOVE EXISTING WATER REMOVE EXISTING ASPHALT LIMITS OF DISTURBANCE TREE REMOVAL DEMOLITION LEGEND APPROXIMATE SAWCUT LIMITS FOR UTILITY CONSTRUCTION (TYP.) REMOVE EXISTING TREES (TYP.) EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT TO BE REMOVED EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT TO BE RELOCATED TO CURB EXISTING 1.5" WATER SERVICE TO BE REMOVED (TYP.) EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING BUILDING ENVELOPE TO BE VACATED (TYP.) EXISTING RIGHT-OF-WAY TO BE VACATED (TYP.) EXISTING RIGHT-OF-WAY TO BE VACATED (TYP.) EXISTING 36" STORM 15' UTILITY, DRAINAGE, GRADING & LANDSCAPE EASEMENT 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT REC. NO. 99055752 EXISTING 8" SANITARY SSMH RIM=5076.5 INV 5062.3 8" PVC INV (SE) 5062.1 8" PVC SSMH RIM=5072.9 INV (E) 5053.5 10" PVC INV (S) 5053.6 8" PVC INV (W) 5058.9 8" PVC INV (W) 5053.7 8" PVC SSMH RIM=5065.2 INV (N) 5054.5 8' PVC INV (W) 5054.8 8" PVC SSMH RIM=5074.0 INV (N) 5060.0 8" PVC INV (E) 5059.6 8" PVC INV (W) 5060.0 8" PVC SSMH RIM=5076.3 INV (N) 5062.1 4" PVC INV (E) 5061.6 8" PVC INV (NW) 5061.9 8" PVC SSMH RIM=5078.2 INV (N) 5063.2 8" PVC INV (E) 5063.5 6" PVC INV (S) 5063.1 8" PVC INV (W) 5063.2 8" PVC SSMH RIM=5063.5 INV (E) 5055.9 8" PVC INV (W) 5055.9 8" PVC SSMH INV (E) 5056.5 8" PVC INV (W) 5056.5 8" PVC SSMH RIM=5061.9 INV (E) 5056.6 8" PVC INV (S) 5056.7 8" PVC SSMH RIM=5075.4 INV (N) 5060.8 8" PVC INV (S) 5060.5 8' PVC PROTECT EXISTING TELECOM PROTECT EXISTING TELECOM PROTECT EXISTING TELECOM EXISTING FIRE HYDRANT EXISTING STOCKPILE PROPERTY BOUNDARY (TYP.) ROAD TO BE RECONSTRUCTED WITH UTILITY CONSTRUCTION (TYP.) EXISTING 10" WATER 68' ROW EXISTING 8" SANITARY 66' ROW 54' ROW PROPERTY BOUNDARY (TYP.) EXISTING FIRE HYDRANT EXISTING BUILDING ENVELOPE TO BE VACATED (TYP.) EXISTING BUILDING ENVELOPE TO BE VACATED (TYP.) REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB FES=5063.6 FES=5068.4 INLET RIM=5072.7 INV (N) 5067.2 36" RCP INV (S) 5066.8 36" RCP INLET INV (N) 5068.7 36" RCP INV (S) 5068.7 36" RCP CITY HIGH RISK FLOODWAY COLLINS SANITATION DISTRICT STANDARDS (LATEST EDITION.) LEGEND NOTES LOT LINES / R.O.W. EASEMENT LINES CENTERLINE MAPPING CURB AND GUTTER INTERMEDIATE CONTOUR INDEX CONTOUR EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. WATER VALVE FIRE HYDRANT LIGHT POLE WATER / SANITARY PLUG WATER METER WATER VAULT FENCE PROPERTY BOUNDARY S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 30' 60' SCALE: 1" = 30' 15' REMOVE EXISTING CONCRETE OR SIDEWALK REMOVE EXISTING CURB AND GUTTER SAWCUT LINE REMOVE EXISTING WATER REMOVE EXISTING ASPHALT LIMITS OF DISTURBANCE TREE REMOVAL DEMOLITION LEGEND APPROXIMATE SAWCUT LIMITS FOR UTILITY CONSTRUCTION (TYP.) APPROXIMATE SAWCUT LIMITS FOR UTILITY CONSTRUCTION (TYP.) REMOVE EXISTING TREES (TYP.) REMOVE EXISTING ENTRANCE PROTECT EXISTING STREET LIGHT PROTECT EXISTING TRANSFORMER EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING 1.5" WATER SERVICE TO BE REMOVED (TYP.) EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT TO BE REMOVED EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT TO BE RELOCATED TO CURB REMOVE EXISTING CURB EXISTING 1.5" WATER SERVICE TO BE REMOVED (TYP.) EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING BUILDING ENVELOPE TO BE VACATED SSMH RIM=5076.5 INV 5062.3 8" PVC INV (SE) 5062.1 8" PVC SSMH RIM=5072.9 INV (E) 5053.5 10" PVC INV (S) 5053.6 8" PVC INV (W) 5058.9 8" PVC INV (W) 5053.7 8" PVC SSMH RIM=5074.0 INV (N) 5060.0 8" PVC INV (E) 5059.6 8" PVC INV (W) 5060.0 8" PVC SSMH RIM=5076.3 INV (N) 5062.1 4" PVC INV (E) 5061.6 8" PVC INV (NW) 5061.9 8" PVC SSMH RIM=5078.2 INV (N) 5063.2 8" PVC INV (E) 5063.5 6" PVC INV (S) 5063.1 8" PVC INV (W) 5063.2 8" PVC SSMH RIM=5075.4 INV (N) 5060.8 8" PVC INV (S) 5060.5 8' PVC SSMH RIM=5076.6 INV (N) 5062.7 8" PVC INV (S) 5062.6 8" PVC SSMH RIM=5076.3 INV (NW) 5062.4 8' PVC INV (S) 5062.3 8" PVC SSMH RIM=5076.9 INV (N) 5064.0 8" PVC INV (E) 5064.1 6" PVC INV (SW) 5064.0 6" PVC EXISTING 30" STORM DRAIN EXISTING 8" WATER EXISTING 8" SANITARY PROTECT EXISTING TELECOM PROTECT EXISTING TELECOM PROTECT EXISTING TELECOM DMH RIM=5075.0 INV (S) 5070.0 30" ADS INV (W) 5070.0 30" ADS DMH RIM=5075.9 INV (N) 5072.2 20" ADS INV (E) 5071.5 24" RCP INV (W) 5071.5 20" ADS INLET GRATE=5076.7 INV (S) 5072.5 20" ADS INLET RIM=5074.9 INV (W) 5070.2 24" RCP INV (E) 5070.2 30" RCP INLET RIM=5075.0 INV (E) 5070.7 24" RCP EXISTING FIRE HYDRANT EXISTING STOCKPILE REMOVE EXISTING ENTRANCE PROPERTY BOUNDARY (TYP.) PROPERTY BOUNDARY (TYP.) ROAD TO BE RECONSTRUCTED WITH UTILITY CONSTRUCTION (TYP.) EXISTING 10" WATER 68' ROW EXISTING 8" SANITARY 66' ROW 54' ROW EXISTING FIRE HYDRANT EXISTING BUILDING ENVELOPE TO BE VACATED (TYP.) REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB INLET RIM=5072.7 INV (N) 5067.2 36" RCP INV (S) 5066.8 36" RCP REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK 5,000 SQ.FT. LOT 3 5,000 SQ.FT. LOT 4 6,719 SQ.FT. LOT 1 5,410 SQ.FT. LOT 2 6,744 SQ.FT. LOT 3 7,887 SQ.FT. LOT 4 6,784 SQ.FT. LOT 1 5,750 SQ.FT. LOT 2 6,384 SQ.FT. LOT 3 7,375 SQ.FT. LOT 4 6,927 SQ.FT. LOT 5 7,358 SQ.FT. LOT 6 7,414 SQ.FT. LOT 7 7,138 SQ.FT. LOT 8 7,113 SQ.FT. LOT 9 5,744 SQ.FT. LOT 10 6,291 SQ.FT. DEDICATED PUBLIC RIGHT OF WAY BY THIS PLAT BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 11 BLOCK 10 BLOCK 12 43,180 SQ.FT. 0.991 ACRES BLOCK 10 OUTLOT C 67,261 SQ.FT. 1.544 ACRES OUTLOT C 67,261 SQ.FT. 1.544 ACRES OUTLOT C 67,261 SQ.FT. 1.544 ACRES BLOCK 11 BLOCK 7 LEGEND KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 5 SEE SHEET 3 OF 5 SEE SHEET 4 OF 5 SEE SHEET 4 OF 5 SEE SHEET 3 OF 5 ** SEE SHEET 2 OF 5 FOR LINE AND CURVE TABLE ** R:\2014615\DWG\2014615SUB.dwg, 11/20/2014 11:13:52 AM 0.406 ACRES BLOCK 11 LEGEND KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 4 SEE SHEET 3 OF 5 SEE SHEET 3 OF 5 SEE SHEET 5 OF 5 SEE SHEET 5 OF 5 ** SEE SHEET 2 OF 5 FOR LINE AND CURVE TABLE ** R:\2014615\DWG\2014615SUB.dwg, 11/20/2014 11:13:47 AM SEE SHEET 5 OF 5 SEE SHEET 5 OF 5 SEE SHEET 4 OF 5 ** SEE SHEET 2 OF 5 FOR LINE AND CURVE TABLE ** R:\2014615\DWG\2014615SUB.dwg, 11/20/2014 11:13:42 AM 6 6 7 7 7 7 7 8 8 8 9 9 10 8 10 TRACT D LEGEND Being a Replat Of Multiple Parcels Of Tract B, Inclusive Of Building Envelope 13 And Building Envelope 14, And A Portion of Tract A, Inclusive Of Building Envelope 1, Building Envelope 6 And Building Envelope 7, Of The Registry Ridge P.U. D., Second Filing And Registry Ridge Fourth Filing City Of Fort Collins, County Of Larimer, State Of Colorado KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 2 R:\2014615\DWG\2014615SUB.dwg, 11/20/2014 11:13:37 AM disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The developer shall implement whatever measures are determined necessary, as directed by the city/county. 16. A vehicle tracking control pad shall be installed when needed for construction equipment, including but not limited to personal vehicles exiting existing roadways. No earthen materials, i.e. stone, dirt, etc. shall be placed in the curb & gutter or roadway as a ramp to access temporary stockpiles, staging areas, construction materials, concrete washout areas, and/or building sites. LARIMER COUNTY URBAN AREA STREET STANDARDS - REPEALED AND REENACTED OCTOBER 1, 2002 GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the Standards and Specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the local entity. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the local entity engineer. Use of these plans after the expiration date will require a new review and approval process by the local entity prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the local entity, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the local entity engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the local entity, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All sanitary sewer, storm sewer, and water line construction, as well as power and other "dry" utility installations, shall conform to the local entity standards and specifications current at the date of approval of the plans by the local entity engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The developer shall be responsible for unknown underground utilities. 7. The developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the local entity prior to beginning construction. 10. The developer shall coordinate and cooperate with the local entity, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 14. A state construction dewatering wastewater discharge permit is required if dewatering is required in order to install utilities or water is discharged into a storm sewer, channel, irrigation ditch or any waters of the united states. 15. The developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the storm water management plan, and the erosion control plan. 16. The local entity shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the local entity, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the storm water utility department. Certification shall be submitted to the storm water utility department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Storm Water Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the development agreement. 18. The local entity including but not limited to City of Fort Collins, South Fort Collins Sanitation District and Fort Collins-Loveland Water District shall not be responsible for any damages or injuries sustained in this development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the local entity failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the final drainage and erosion control study entitled "Registry Ridge Seventh Filing" prepared by United Civil Design Group LLC, and dated November 20, 2014, shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the erosion control plan. All erosion control measures shall be maintained in good repair by the developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the local entity street inspector. 22. No work may commence within any improved or unimproved public right-of-way until a right-of-way permit or development construction permit is obtained, if applicable. 23. The developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The developer shall notify the local entity engineering inspector (Fort Collins - 221-6605) and the local entity erosion control inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the local entity engineer is not available after proper notice of construction activity has been provided, the developer may commence work in the engineers absence. However, the local entity reserves the right not to accept the improvement if subsequent testing reveals an improper installation 24. The developer shall be responsible for obtaining soils tests within the public right-of-way after right-of-way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the developer shall be responsible for a re-design of the subject pavement section or, the developer may use the local entity's default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed professional engineer. The final report shall be submitted to the inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the local entity engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the local entity inspector. The engineer or surveyor must certify in a letter to the local entity that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the local entity before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County floodplain resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as wild fire hazard areas shall be done in accordance with the construction criteria as established in the wild fire hazard area mitigation regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the local entity forester to schedule a site inspection for any tree removal requiring a permit. 30. The developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The developer shall submit a construction traffic control plan, in accordance with MUTCD, to the appropriate right-of-way authority. (local entity, county or state), for approval, prior to any construction activities within, or affecting, the right-of-way. The developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact local entity traffic operations department, who will temporarily remove or relocate the sign at no cost to the contractor; however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The developer is responsible for all costs for the initial installation of traffic signing and striping for the development related to the development's local street operations. In addition, the developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the local entity engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the local entity. GENERAL NOTES (CONTINUED) 35. The developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the designer for clarification, and annotate the dimension on the as-built record drawings. 37. The developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the developer shall contact the designer and the local entity engineer immediately. 39. The developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the local entity's inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the local entity engineer. 40. The designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: BENCHMARK #1: CITY OF FORT COLLINS 10-13 SOUTHEAST CORNER OF SHIELDS ST. AND TRILBY ROAD. , ON A CONCRETE TRAFFIC SIGNAL BASE. ELEVATION=5063.75 (CITY OF FORT COLLINS-NGVD 1929 DATUM UNADJUSTED) ELEVATION=5066.93 (NAVD 88 DATUM) BENCHMARK #2: CITY OF FORT COLLINS 45-01 SOUTH SIDE OF TRILBY ROAD, APPROXIMATELY 0.5 MILES EAST OF TAFT HILL ROAD, ON AN 8'x8' CONCRETE PAD FOR A WATER VALVE AND A LARGE BLACK PIPE. ELEVATION=5066.19 (CITY OF FORT COLLINS-NGVD 1929 DATUM UNADJUSTED) ELEVATION=5069.38 (NAVD 88 DATUM) BASIS OF BEARINGS: $6680,1*7+(($67/,1(2)7+(1257+($6748$57(52)6(&7,21715:$6%($5,1*1257+ƒ ($67%(,1*$*5,'%($5,1*2)7+(&2/25$'267$7(3/$1( COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983/2007, A DISTANCE OF 2640.82 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first certificate of occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the local entity construction inspector before any cuts are made. Patching shall be done in accordance with the local entity street repair standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the local entity engineer and/or the local entity inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the local entity, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The local entity shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: none. 48. Approved variances are listed as follows: -None. STREET IMPROVEMENTS NOTES 1. All street construction is subject to the General Notes on the Cover Sheet of these plans as well as the street improvements notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed engineer, must be submitted to the local entity engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the local entity engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the local entity engineer. 5. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, reconstruction and repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the local entity engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in MUTCD (including Colorado supplement) and as per the right-of-way work permit traffic control plan. 8. The developer is required to perform a gutter water flow test in the presence of the local entity inspector and prior to installation of asphalt. Gutters that hold more than inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. And a single axle weight of at least 18,000 lbs. With pneumatic tires inflated to not less than 90 P.S.I.G. "proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the local entity engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The local entity engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be performed in the presence of an inspector. TRAFFIC SIGNING AND PAVEMENT MARKING CONSTRUCTION NOTES 1. All signage and marking is subject to the General Notes on the Cover Sheet of these plans, as well as the traffic signing and marking construction notes listed here. 2. All symbols, including arrows, ONLY's, crosswalks, stop bars, etc. shall be preformed thermoplastic. 3. All signage shall be per local entity standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Preformed thermoplastic applications shall be as specified in these plans and/or these standards. 8. Epoxy applications shall be applied as specified in CDOT standard specifications for road and bridge construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer . All discrepancies identified during the field inspection must be corrected before the two year warranty period will begin. CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: GENERAL NOTES C001 N/A N/A SOUTH SIDE OF TRILBY ROAD, APPROXIMATELY 0.5 MILES EAST OF TAFT HILL ROAD, ON AN 8'x8' CONCRETE PAD FOR A WATER VALVE AND A LARGE BLACK PIPE. ELEVATION=5066.19 (CITY OF FORT COLLINS-NGVD 1929 DATUM UNADJUSTED) ELEVATION=5069.38 (NAVD 88 DATUM) BASIS OF BEARINGS: ASSUMING THE EAST LINE OF THE NORTHEAST QUARTER OF SECTION 15, T.6N., R.69W., $6%($5,1*1257+ƒ ($67%(,1*$*5,'%($5,1*2)7+(&2/25$'267$7( PLANE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983/2007, A DISTANCE OF 2640.82 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. NOTE: 1. ALL PROJECT CONTROL LISTED HEREON IS PROVIDED AS A COURTESY. IT IS THE RESPONSIBILITY OF THE RECIPIENT TO VERIFY THE ACCURACY OF THE COORDINATES AND ELEVATIONS SHOWN PRIOR TO USING THEM FOR ANY PURPOSES. UTILITY PROVIDER CONTACT PHONE Water/Wastewater City of Fort Collins Utilities Roger Buffington (970) 221-6854 Stormwater City of Fort Collins Utilities Glen Schlueter (970) 221-6700 Power City of Fort Collins Light & Power Jim Spaulding (970) 416-2772 Natural Gas Xcel Energy Stephanie Rich (970) 225-7828 Telecom Centurylink Bill Johnson (970) 377-6401 Cable Comcast Don Kapperman (970) 567-0245 Note: All utility providers listed hereon is provided as a courtesy. It is the responsibility of the recipient to verify the accuracy and completeness of the information shown. UTILITY PROVIDERS PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION CITY OF FORT COLLINS 11/20/14 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R Mr. Terry W. Farrill, P.E., District Engineer Mr. Michael D. DiTullio, Manager Date Date All changes, addendum, additions, deletions and modifications to these drawings must be approved in writing, by the Fort Collins - Loveland Water District and the South Fort Collins Sanitation District. SHEET INDEX SHEET # SHEET NAME C000 COVER SHEET C001 GENERAL NOTES SUBDIVISION PLAT (FOR REFERENCE ONLY) C100-C101 EXISTING CONDITIONS & REMOVALS C200-C201 HORIZONTAL CONTROL PLAN C300-C301 UTILITY PLAN C400-C401 SANITARY SEWER PLAN & PROFILES C500 STORM SEWER PLAN & PROFILES (RESERVED FOR FINAL SUBMITTAL) C600-C601 OVERLOT GRADING & EROSION CONTROL PLAN C602-C603 DETAILED GRADING PLANS (RESERVED FOR FINAL SUBMITTAL) C700 HORNET DRIVE CENTERLINE STREET PLAN & PROFILE C701 INTERSECTION DETAILS (RESERVED FOR FINAL SUBMITTAL) C702 SIGNING & STRIPING PLAN (RESERVED FOR FINAL SUBMITTAL) C800 DRAINAGE PLAN C900 CONSTRUCTION DETAILS (RESERVED FOR FINAL SUBMITTAL) PLANNER/LANDSCAPE ARCHITECT GREENSCAPE DESIGNS 1501 ACADEMY CT., STE 202 FORT COLLINS, CO 80524 PHONE: 970-631-2822 CONTACT: JENNIFER GARDNER COVER SHEET C000 N/A N/A PROJECT SITE S. SHIELDS STREET W. TRILBY ROAD B O N H O M M E R I C H A R D DRIVE TRUXUN DRIVE