Loading...
HomeMy WebLinkAboutRIVERSIDE COMMUNITY SOLAR GARDEN - FDP - FDP140027 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE, LANDSCAPE & ELEVATIONS PLANSRIVERSIDE AVENUE EAST MULBERRY STREET PHASE I - 333 kW (2.36AC) PHASE II - 192 kW (1.12 AC) EXISTING RAILROAD TRACKS MULBERRY WATER RECLAMATION FACILITY PROJECT DEVELOPMENT BOUNDARY CACHE LA POUDRE RIVER PROPERTY LINE EXISTING BUILDING (TO BE REMOVED) E MULBERRY ST S TIMBERLINE RD N LEMAY AVE INTERNATIONAL BLVD E LINCOLN AVE S LINK LN E PROSPECT RD RIVERSIDE AVENUE FILE DATE NO. DATE DSGN DR REVISION CHK APVD SHEET DWG VERIFY SCALE BAR IS ONE INCH ON ORIGINAL DRAWING. 0 SCALE 1437 LARIMER STREET DENVER, COLORADO 80202 CLEAN ENERGY COLLECTIVE RIVERSIDE COMMUNITY SOLAR GARDEN FORT COLLINS, COLORADO REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF ENERTIA CONSULTING GROUP AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF ENERTIA CONSULTING GROUP OCTOBER 09, 2014 COVER SHEET JSO MGB JSO JSO CLEAN ENERGY COLLECTIVE RIVERSIDE COMMUNITY SOLAR GARDEN PLANNING DOCUMENTS LOCATED IN THE SOUTHWEST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 12, TOWNSHIP 7 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO LEGAL DESCRIPTION: SHEET INDEX: SHEET 1 - COVER SHEET SHEET 2 - SITE PLAN SHEET 3 - LANDSCAPE PLAN SHEET 4 - TYPICAL DETAILS STANDARD NOTES: 1. THE SPECIFIED SOLAR PANELS, RACKING SYSTEM, AND RIVERSIDE AVENUE EAST MULBERRY STREET PHASE I - 333 kW (2.36AC) PHASE II - 192 kW (1.12 AC) 20' (TYP) EXISTING RAILROAD TRACKS MULBERRY WATER RECLAMATION FACILITY PROJECT DEVELOPMENT BOUNDARY CACHE LA POUDRE RIVER EAST MULBERRY STREET R.O.W. EXISTING EDGE OF ASPHALT (TYP) 10 EX.' DIRT TRACK EXISTING DRIVE 20' ASPHALT ACCESS DRIVE 12' UTILITY ACCESS (UTILITY PERSONNEL ONLY) 10' CONCRETE MULTI MODAL PATH 9'-17' LANDSCAPE BUFFER 20' MIN SETBACK SEE UTILITY PLAN DOCUMENTS SHT 3 50' 50' R = 2 5 ' R = 2 5 ' 20' 12' PHASE II UTILITY ACCESS (UTILITY PERSONNEL ONLY) 20' EXISTING VEGETATION EXISTING VEGETATION HABITAT BUFFER ZONE R=25' 10' FUTURE MULTI MODAL PATH (BY FC UTILITIES) 10' MULTI MODAL PATH SEE UTILITY PLAN DOCUMENTS SHT 3 115' MIN BUFFER 20' SETBACK 7' HIGH FENCE (SEE DETAIL ON SHT 4) INVERTER PAD TRANSFORMER PAD PROPERTY LINE RIVERSIDE AVENUE EAST MULBERRY STREET EXISTING RAILROAD TRACKS MULBERRY WATER RECLAMATION FACILITY PROJECT DEVELOPMENT BOUNDARY CACHE LA POUDRE RIVER 12 1 2 3 4 5 6 7 8 9 10 11 EXISTING EDGE OF ASPHALT (TYP) SEE THIS SHEET FOR EXISTING TREE INVENTORY NUMBER INFORMATION 6' TRAIL ALIGNMENT (BY OTHERS) AG (TYP) SOLAR ARRAY (TYP) 6' HIGH FENCE (SEE DETAIL ON SHEET # ) PROPERTY LINE EXISTING VEGETATION TO REMAIN WITHIN SOLAR GARDEN SEED MIX (TYP) PROVIDE MULCHING TO PROTECT EXISTING GROUND AND ROOT SYSTEMS TEMPORARY ACCESS EXPANSION R50' TEMPORARY ACCESS EXPANSION 20' 5' EXPANSION PROVIDE MULCHING TO PROTECT EXISTING GROUND AND ROOT SYSTEMS EXISTING VEGETATION TO REMAIN WITHIN SOLAR GARDEN 6' HIGH FENCE (SEE DETAIL ON SHEET #) PRVIM (TYP) EXISTING TREES TO REMAIN PER EXISTING TREE INVENTORY TABLE ON SHEET# (TYP) PROPERTY LINE SEE SHEET # FOR EXISTING TREE INVENTORY NUMBER (TYP) 20' SETBACK (TYP) 20' SETBACK (TYP) 2' FENCE LINE SETBACK (TYP) 20' (TYP) SOLAR MODULES (TYP) DRIVEN STEEL SUPPORT COLUMNS (SPACED 10' O.C. TYP) 6' - 8' HIGH FENCE EXISTING GROUND VEGETATION TO REMAIN PROPERTY LINE 6' - 8' HIGH FENCE FILE DATE NO. DATE DSGN DR REVISION CHK APVD SHEET DWG VERIFY SCALE BAR IS ONE INCH ON ORIGINAL DRAWING. 0 SCALE 1437 LARIMER STREET DENVER, COLORADO 80202 CLEAN ENERGY COLLECTIVE RIVERSIDE COMMUNITY SOLAR GARDEN FORT COLLINS, COLORADO REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF ENERTIA CONSULTING GROUP AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF ENERTIA CONSULTING GROUP OCTOBER 09, 2014 JSO MGB JSO JSO TYPICAL SOLAR GARDEN SECTION VIEW (VIEW FROM RIVERSIDE AVENUE) SCALE: 1" = 10' TYPICAL DETAILS PV ARRAY RACKING SYSTEM NOT TO SCALE MESH FENCING WOOD POST (TYP) 7' TYPICAL MESH FENCE DETAIL NOT TO SCALE 7' 4'' PLACE CONCRETE 6'' MIN AROUND POST DTL 1 OF 4 PLANNING DOCUMENTS PLNG SOLAR ARRAY (TYP) CHOKECHERRY TO BE PLANTED AS MITIGATION FOR TREE No. 3 REMOVAL 15 14 13 EXISTING VEGETATION TO REMAIN WITHIN SOLAR GARDEN EXISTING VEGETATION TO REMAIN FILE DATE NO. DATE DSGN DR REVISION CHK APVD SHEET DWG VERIFY SCALE BAR IS ONE INCH ON ORIGINAL DRAWING. 0 SCALE 1437 LARIMER STREET DENVER, COLORADO 80202 CLEAN ENERGY COLLECTIVE RIVERSIDE COMMUNITY SOLAR GARDEN FORT COLLINS, COLORADO REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF ENERTIA CONSULTING GROUP AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF ENERTIA CONSULTING GROUP OCTOBER 09, 2014 LANDSCAPE PLAN JSO MGB JSO JSO PROPOSED LANDSCAPE BUFFER GENERAL NOTES: 1. PLANTS SHALL BE DROUGHT RESISTANT AND WILL INITIALLY BE HAND WATERED TO ESTABLISHMENT FOR A MINIMUM OF 3 YEARS. THE FREQUENCY AND AMOUNT OF IRRIGATION WATER APPLIED SHALL FOLLOW THE RECOMMENDATION OF A QUALIFIED LANDSCAPE HORTICULTURIST THE QUALIFIED HORTICULTURIST SHALL MAKE INSPECTIONS OF TREES AND SHRUBS DURING THE 3 YR ESTABLISHMENT PERIOD AND MAY ADVISE INCREASED IRRIGATION FREQUENCY OR EXTRA YEARS OF IRRIGATION TO ENSURE ESTABLISHMENT. 2. MULCHING SHALL BE PLACED IN AREAS WHERE SOIL COMPACTION AND DAMAGE TO ROOT SYSTEMS IS REQUIRED TO BE MINIMAL. 3. TRAIL ALIGNMENT IS FOR ILLUSTRATIVE PURPOSES ONLY AND IS SUBJECT TO CHANGE. 4. SEE THIS SHEET FOR ADDITIONAL NOTES, DETAILS, AND PLANT SCHEDULE. 3. THE PV ARRAYS SHALL BE INSTALLED AT EXISTING GRADE WITHOUT CLEARING OR GRUBBING OF VEGETATION. 7. THE OBJECTIVE OF THE BUFFER ZONE IS TO PROTECT THE ECOLOGICAL CHARACTER OF THE NATURAL HABITAT FROM THE IMPACTS OF THE ACTIVITIES ASSOCIATED WITH THE DEVELOPMENTS AND SHOULD BE MAINTAINED AS NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER ZONE. 8. IF AREA WITHIN THE HABITAT BUFFER ZONE BECOMES DISTURBED DURING CONSTRUCTION ACTIVITIES, THE DEVELOPER SHALL RESEED THE AFFECTED AREA AND RESTORE NATIVE CONDITIONS SUFFICIENTLY. HOWEVER, ANY FURTHER LANDSCAPING, PLANTING AND MAINTENANCE OF THAT AREA SHALL BE THE RESPONSIBILITY OF FORT COLLINS UTILITIES DEPT. 9. BARE AREAS WITHIN THE HABITAT BUFFER ZONE SHALL BE RE-SEEDED. RE-SEEDING SHALL BE THE RESPONSIBILITY OF THE FORT COLLINS UTILITY DEPARTMENT. 10' MULTI MODAL PATH SEE UTILITY PLAN DOCUMENTS SHT 3 PROPOSED FENCE (SEE DETAIL ON SHT 3) AG. (TYP) LOW SEED MIX (TYP) 9'-17' LANDSCAPE BUFFER HABITAT BUFFER ZONE LANDSCAPE/PLANTING (BY FC UTILITIES) HABITAT BUFFER ZONE LANDSCAPE/PLANTING (BY FC UTILITIES) 115' MIN BUFFER HABITAT BUFFER ZONE ARRAY (TYP) PROPOSED ACCESS DRIVE EXISTING DRIVE EXISTING FENCE 20' SETBACK TOP OF BANK EX. ASPHALT (TO REMAIN UNTIL FUTURE RESORATION) EXISTING TREES TO REMAIN (TYP) SEED NOTES: 1. SEED SHALL BE LABELED IN ACCORDANCE WITH THE U.S. DEPARTMENT OF AGRICULTURE, RULES AND REGULATIONS AND FEDERAL SEED ACT. SEED SHALL BE EQUAL IN QUALITY TO THE STANDARDS FOR "CERTIFIED SEED" AND SHALL BE FURNISHED IN SEALED, UNOPENED, STANDARD CONTAINERS. SEED SHALL BE FRESH, CLEAN, PURE LIVE SEED WITH THE VARIETIES MIXED IN PROPORTIONS BY WEIGHT SHOWN AND MEETING THE MINIMUM PERCENTAGES OF PURITY AND GERMINATION SPECIFIED. 2. SEED SHALL BE APPLIED AT A RATE SHOWN BY MIX. SEED SHALL PASS GOVERNMENT TEST OF GERMINATION OF EIGHTY PERCENT (80%) AND FOR PURITY OF NINETY PERCENT (90%). THE PURE LIVE SEED SHALL NOT BE LESS THAN SIXTY SEVEN ON ONE-HALF PERCENT (67.5%) FOR ANY ONE VARIETY, WITH THE AVERAGE OF THE MIXTURE, NO LESS THAN SEVENTY TWO PERCENT (72%). ALL SEED SHALL BE FREE OF POA ANNUA AND ALL NOXIOUS OBJECTIONABLE WEEDS WITH A MAXIMUM CROP OF ONE-TENTH PERCENT (0.1%) AND MAXIMUM WEED OF ONE TENTH PERCENT (0.1%). IF SEED AVAILABLE ON THE MARKET DOES NOT MEET THE MINIMUM PURITY AND GERMINATION PERCENTAGES SPECIFIED, THE CONTRACTOR MUST COMPENSATE BY FURNISHING SUFFICIENT ADDITIONAL SEED TO EQUAL THE SPECIFIED PRODUCT. 3. SPREAD ORGANIC SOIL AMENDMENT MATERIALS, AT A RATE OF 2 C.Y. PER 1000 SQUARE FEET, EVENLY OVER ENTIRE AREA AND THOROUGHLY INCORPORATE, BY MIXING, ROTOTILLING OR FINELY DISKING (MAX. 1" SIZE), TO A DEPTH OF SIX INCHES. ALL STONES, STICKS AND DEBRIS BROUGHT TO THE SURFACE SHALL BE REMOVED FROM THE SITE PROPERLY DISPOSED OF BY THE CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER. ALL SEED AREAS WILL THEN BE RAKED AND ROLLED TO THE DESIRED FINISHED GRADES WITH GENTLY SLOPING SURFACES TO ADEQUATELY DRAIN ALL SURFACE WATER RUNOFF. THE FINISHED SURFACE SHALL BE EVEN AND UNIFORM AND NO DIRT CLODS LARGER THAN ONE INCH (1") IN DIAMETER SHALL APPEAR ON THE SURFACE. THE SOIL SURFACE SHALL BE SMOOTH, LOOSE AND OF FINE TEXTURE, AND BE FLUSH WITH ALL PAVING EDGES. 4. CONTRACTOR SHALL USE APPROPRIATE MECHANICAL POWER (BRILLION SEEDER OR EQUAL) TO DRILL THE SEED INTO THE SEEDBED WHEREVER POSSIBLE. SEED SHALL BE SOWN TO A DEPTH OF ONE-HALF INCH (1 2"). DRILLING SHALL BE DONE IN 2 SEPARATE APPLICATIONS CROSSING THE AREA AT RIGHT ANGLES TO ONE ANOTHER TO GURANTEE PROPER COVERAGE. ON SLOPING LAND, SEEDING OPERATIONS SHALL FOLLOW THE GENERAL CONTOUR. AREAS TOO SMALL TO DRILL SEED MAY BE BROADCAST BY HAND AND APPLICATION RATES SHALL BE DOUBLED. SEEDING OF ANY KIND WILL NOT BE PERMITTED WHEN WIND VELOCITY IS SUCH AS TO PREVENT UNIFORM SEED DISTRIBUTION. NO APPLICATION SHALL TAKE PLACE WITH THE PRESENCE OF FREE SURFACE WATER OR WHEN GROUND IS FROZEN OR CANNOT BE TILLED. 5. ALL SEED AREAS SHALL BE HYDRO MULCHED WITH A FIBROUS SLURRY MIXTURE CONTAINING A TACKIFIER AGENT WITHIN 24 HOURS OF DRILLING OR BROADCAST AT A RATE OF 2,000 LBS. PER ACRE. LANDSCAPE & SOIL PREPARATION NOTES: 1. ALL PLANT MATERIALS ARE TO BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. PLANT SPECIES MAY NOT BE SUBSTITUTED WITHOUT WRITTEN PERMISSION FROM THE LANDSCAPE ARCHITECT. 2. ALL SHRUB BEDS ARE TO BE MULCHED WITH FIR FIBER MULCH AT A CONSISTENT DEPTH OF 4". SUBMIT SAMPLE FOR APPROVAL PRIOR TO INSTALLATION. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE TO EXISTING UTILITIES, CURB AND GUTTER, WALLS, OR WALKWAYS AND OTHER STRUCTURES THAT IS A RESULT OF THEIR WORK. THE REPAIR OF SUCH DAMAGE WILL BE AT NO ADDITIONAL COST TO THE OWNER. 4. THE CONTRACTOR SHALL FINE GRADE ALL AREAS TO BE PLANTED. THE CONTRACTOR SHALL REMOVE REQUIRED DEPTH OF SOIL ALONG WALKWAYS TO ACCOMMODATE SOD OR MULCH DEPTH. 5. TEST PRE-EXISTING SOIL IN LANDSCAPE AREA FOR MINERAL AND ORGANIC MATTER CONTENT TO DETERMINE PROPER SOIL AMENDMENTS BASED ON RESULTS OF THE SOIL TEST. 6. PREPARE PLANTING BEDS PER SPECIFICATIONS. 7. NON-DYED SHREDDED CEDAR MULCH IS THE PREFERRED MULCH IN ALL AREAS VISIBLE FROM THE STREET. 8. INSTALL A CONTINUOUS COMMERCIAL GRADE WEED BARRIER AT PLANTING TIME, WHERE APPROPRIATE. 9. INSTALL A CONTINUOUS EDGER BETWEEN THE PLANT BED AND LAWN, AND BETWEEN WOOD AND ROCK MULCH AREAS. 10. TREES PLANTED IN TURF AREAS SHOULD HAVE A MINIMUM 48" DIAMETER MULCH RING SURROUNDING THE TRUNK. DO NOT PLACE MULCH DIRECTLY AGAINST THE TREE TRUNK. 11. PLANT TREES AND SHRUBS PER DETAILS AND SPECIFICATIONS. 12. FORM SOIL INTO A 3” TO 5” TALL WATERING RING (SAUCER) AROUND PLANTING AREA. THIS IS NOT NECESSARY IN IRRIGATED TURF AREAS. APPLY 4” DEPTH OF SPECIFIED MULCH INSIDE WATERING RING. TREE PROTECTION NOTES: 1. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 2. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. 3. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 4. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 5. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 6. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3). THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 7. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART ON THIS SHEET. SEED MIX (TYP) EXISTING BUILDING (TO BE REMOVED) EXISTING TRACKS TOP OF BANK EX. GATE LOW SEED MIX (10,00 SF) TREE DIAMETER AT BREAT HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0 - 2 1 3 - 4 2 5 - 9 5 10 - 14 10 15 - 19 12 OVER 19 15 AUGER-TREE CLEARANCE HABITAT BUFFER ZONE LEGEND ROCKY MOUNTAIN JUNIPER TALL GRASSES NATIVE SEED MIX AUTUMN BRILLIANCE SERVICE BERRY CHOKE CHERRY LOW GRASS SEED E.G. CANADA WILDRYE OR PERENNIALS WOOD ROSE, CURRANT, FALSE INDIGO BUSH, RABBIT BRUSH, SERVICE BERRY, BOULDER RASPBERRY (MIX RATIO TO BE THE RESPONSIBILITY OF FORT COLLINS) PLANT LIST TREE AND SHRUB PLANTING FUTURE TRAIL (BY FC UTILITES) TYPE III BARRICADE LSP 1 OF 3 PLANNING DOCUMENTS PRVIM. (TYP) W/ 3'' TO 5'' WATER SAUCER W/ 3'' TO 5'' WATER SAUCER NOTE: THE DISTANCE BETWEEN THE CONCRETE MULTI MODAL PATH AND THE CENTER OF ANY SHRUB/TREE SHALL BE A MIN OF 5' MULTI MODAL PATH & LANDSCAPE DESIGNATED AREA PLNG 100YR FLOOD ZONE 500 YEAR FLOOD ZONE FLOOD ZONE LINE 100 YR FLOOD ZONE 100YR FLOOD ZONE SEED MIX (TYP) EXISTING BUILDING (TO BE REMOVED) SEE SHEET 3 FOR LANDSCAPE DETAILS EXISTING CONCRETE (TO BE REMOVED) EXISTING CONCRETE (TO BE REMOVED) PROJECT DEVELOPMENT BOUNDARY EX TREES TO REMAIN (TYP.) EX. GAS LINE (TO BE ABANDONED) EX. ABANDONED TELEPHONE EXISTING CONCRETE EX. FENCE CHAIN LINK W/BARED WIRE (TO BE MODIFIED AS SHOWN) TIE TO EXISTING FENCE TIE TO EXISTING FENCE EX. STORM INLET EXISTING CONCRETE (TO BE REMOVED) GATE EXISTING ASPHALT (TO REMAIN UNTIL FUTURE RESORATION) TOP OF BANK TOP OF BANK EXISTING CONCRETE (TO BE REMOVED) EX. RETAINING WALL (TO REMAIN) SOLAR ARRAY (TYP) EX. GATE TOP OF BANK TYPE III BARRICADE HABITAT BUFFER ZONE LANDSCAPE/PLANTING BY FC UTILITIES (SEE SHT 3) EXISTING CONCRETE WALK (TYP) HABITAT BUFFER ZONE LANDSCAPE/PLANTING BY FC UTILITIES (SEE SHT 3) REMOVE AND REPLACE ACCESS RAMP (SEEUTILITY PLAN DOCUMENTS SHT 3) 7' HIGH FENCE (SEE DETAIL ON SHT 4) GRAVEL EMERGENCY TURNAROUND MULTI MODAL PATH & LANDSCAPE DESIGNATED AREA 100YR FLOOD ZONE 500 YEAR FLOOD ZONE FLOOD ZONE LINE 100 YR FLOOD ZONE 100YR FLOOD ZONE FILE DATE NO. DATE DSGN DR REVISION CHK APVD SHEET DWG VERIFY SCALE BAR IS ONE INCH ON ORIGINAL DRAWING. 0 SCALE 1437 LARIMER STREET DENVER, COLORADO 80202 CLEAN ENERGY COLLECTIVE RIVERSIDE COMMUNITY SOLAR GARDEN FORT COLLINS, COLORADO REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF ENERTIA CONSULTING GROUP AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF ENERTIA CONSULTING GROUP OCTOBER 09, 2014 SITE PLAN JSO MGB JSO JSO GENERAL NOTES: 1. THE SPECIFIED SOLAR PANELS, RACKING SYSTEM, AND INVERTER/TRNASFORMER ARE INTENDED TO ILLUSTRATE *(1(5$/,1)250$7,21$%2877+(&20321(1762)7+(62/$5*$5'(1&20321(1767+$7$5(6,0,/$5,1 APPEARANCE AND FUNCTION MAY BE SUBSTITUTED FOR THE COMPONENTS SPECIFIED OR ILLUSTRATED ON THIS 6,7(3/$17+(/2&$7,212)7+($55$<6$1',19(57(560$<9$5<)520:+$7,6'(3,&7('217+,66,7( PLAN, PROVIDED THE INSTALLED COMPONENTS MEET ALL REQUIRED SETBACKS. 2. LOCATION OF INVERTER PAD AND TRANSFORMER PAD MAY CHANGE. IF CHANGES ARE NECESSARY THE EQUIPMENT SHALL BE PLACED IN SUCH A WAY SO THAT THEY ARE SCREENED AND ARE NOT VISIBLE FROM THE PUBLIC RIGHT OF WAY. 3. THE PV ARRAYS SHALL BE INSTALLED AT EXISTING GRADE WITHOUT CLEARING OR GRUBBING OF VEGETATION. 4. THE PROPOSED MULTI MODAL PATH ALIGNMENT IS FOR ILLUSTRATIVE PURPOSES ONLY AND IS SUBJECT TO CHANGE. TRAIL CONSTRUCTION WILL BE COORDINATED WITH FORT COLLINS UTILITIES DEPARTMENT WHO HOLDS RESPONSIBILITY FOR THIS SITE IMPROVEMENT TO BE COMPLETED IN STAGES. 5. SEE LANDSCAPE PLANS FOR EXISTING TREE LOCATIONS. 6. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS & GUTTERS, DESTROYED, DAMAGED, OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPERS EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 7. THE OBJECTIVE OF THE BUFFER ZONE IS TO PROTECT THE ECOLOGICAL CHARACTER OF THE NATURAL HABITAT FROM THE IMPACTS OF THE ACTIVITIES ASSOCIATED WITH THE DEVELOPMENTS AND SHOULD BE MAINTAINED AS NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER ZONE. 8. IF AREA WITHIN THE HABITAT BUFFER ZONE BECOMES DISTURBED DURING CONSTRUCTION ACTIVITIES, THE DEVELOPER SHALL RESEED THE AFFECTED AREA AND RESTORE NATIVE CONDITIONS SUFFICIENTLY. HOWEVER, ANY FURTHER LANDSCAPING, PLANTING AND MAINTENANCE OF THAT AREA SHALL BE THE RESPONSIBILITY OF FORT COLLINS UTILITIES DEPT. 9. THE VERTICAL CURB AND GUTTER ADJACENT TO THE ACCESS DRIVE SHALL REMAIN IN PLACE. GUTTER RAMPS SHALL BE USED DURING CONSTRUCTION ACTIVITIES TO PREVENT THE CURB AND GUTTER FROM BECOMING DAMAGED. OSP 1 OF 2 PLANNING DOCUMENTS PLNG INVERTERS ARE INTENDED TO ILLUSTRATE GENERAL INFORMATION ABOUT THE COMPONENTS OF THE SOLAR )$&,/,7<&20321(1767+$7$5(6,0,/$5,1$33($5$1&( AND FUNCTION MAY BE SUBSTITUTED FOR THE COMPONENTS 63(&,),('25,//8675$7('217+,66,7(3/$17+( LOCATION OF THE ARRAYS AND INVERTERS MAY VARY SLIGHTLY FROM WHAT IS DEPICTED ON THIS SITE PLAN, PROVIDED THE INSTALLED COMPONENTS MEET ALL REQUIRED SETBACKS. 2. THE ENGINEER WHO HAS PREPARED THESE PLANS, BY EXECUTION AND/OR SEAL HEREOF, DOES HEREBY AFFIRM RESPONSIBILITY TO THE LOCAL ENTITY, AS BENEFICIARY OF SAID ENGINEER'S WORK, FOR ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS, AND APPROVAL OF THESE PLANS BY THE LOCAL ENTITY ENGINEER SHALL NOT RELIEVE THE ENGINEER WHO HAS PREPARED THESE PLANS OF ALL SUCH RESPONSIBILITY. FURTHER, TO THE EXTENT PERMITTED BY LAW, THE ENGINEER HEREBY AGREES TO HOLD HARMLESS AND INDEMNIFY THE LOCAL ENTITY, AND ITS OFFICERS AND EMPLOYEES, FROM AND AGAINST ALL LIABILITIES, CLAIMS, AND DEMANDS WHICH MAY ARISE FROM ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS. OVERALL SITE AREA SCALE 1" = 100' APPLICANT CLEAN ENERGY COLLECTIVE 3005 CENTER GREEN DRIVE, SUITE 205 BOULDER, CO 80301 CONTACT: MICHELLE ZIMMERMAN (303) 881-3087 ENGINEER ENERTIA CONSULTING GROUP, LLC 1437 LARIMER STREET DENVER, COLORADO 80202 CONTACT: SEAN O'HEARN, PE, PG (303) 473-3131 SURVEYOR PRECISION SURVEY 9145 EAST KENYON AVENUE #101 DENVER, COLORADO 80237 CONTACT: CHRIS JULIANA, PLS (303) 825-4822 VICINITY MAP SCALE 1" = 2000'± CVR 1 OF 1 SITE GENERAL LEGEND PROJECT DEVELOPMENT BOUNDARY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED FENCE SETBACK LINE RIGHT-OF-WAY PROPERTY LINE EXISTING UNDERGROUND ELECTRIC EXISTING UNDERGROUND TELECOMMUNICATIONS EXISTING GAS LINE UTILITY EXISTING DRIVE PROPOSED ACCESS PLANNING DOCUMENTS PROPOSED FENCE MULTI MODAL PATH & LANDSCAPE DESIGNATED AREA ENGINEER CERTIFICATION I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO STANDARDS AND STATUTES, RESPECTIVELY; AND THAT I AM FULLY RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN, REVISIONS, AND RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS. DISCLAIMER STATEMENT: THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. DATE: PLNG