HomeMy WebLinkAboutRIVERSIDE COMMUNITY SOLAR GARDEN - FDP - FDP140027 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE, LANDSCAPE & ELEVATIONS PLANSRIVERSIDE AVENUE
EAST MULBERRY STREET
PHASE I - 333 kW (2.36AC)
PHASE II - 192 kW (1.12 AC)
EXISTING RAILROAD TRACKS
MULBERRY WATER
RECLAMATION FACILITY
PROJECT DEVELOPMENT
BOUNDARY
CACHE
LA
POUDRE
RIVER
PROPERTY LINE
EXISTING BUILDING
(TO BE REMOVED)
E MULBERRY ST
S TIMBERLINE RD
N LEMAY AVE
INTERNATIONAL
BLVD
E LINCOLN AVE
S LINK LN
E PROSPECT RD
RIVERSIDE AVENUE
FILE
DATE
NO. DATE
DSGN DR
REVISION
CHK APVD
SHEET
DWG
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
0 SCALE
1437 LARIMER STREET
DENVER, COLORADO 80202
CLEAN ENERGY COLLECTIVE
RIVERSIDE COMMUNITY SOLAR GARDEN
FORT COLLINS, COLORADO
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF ENERTIA
CONSULTING GROUP AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF ENERTIA CONSULTING GROUP
OCTOBER 09, 2014
COVER SHEET JSO MGB JSO JSO
CLEAN ENERGY COLLECTIVE
RIVERSIDE COMMUNITY SOLAR GARDEN
PLANNING DOCUMENTS
LOCATED IN THE SOUTHWEST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 12,
TOWNSHIP 7 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN,
CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
LEGAL DESCRIPTION:
SHEET INDEX:
SHEET 1 - COVER SHEET
SHEET 2 - SITE PLAN
SHEET 3 - LANDSCAPE PLAN
SHEET 4 - TYPICAL DETAILS
STANDARD NOTES:
1. THE SPECIFIED SOLAR PANELS, RACKING SYSTEM, AND
RIVERSIDE AVENUE
EAST MULBERRY STREET
PHASE I - 333 kW (2.36AC)
PHASE II - 192 kW (1.12 AC)
20' (TYP)
EXISTING RAILROAD TRACKS
MULBERRY WATER
RECLAMATION FACILITY
PROJECT DEVELOPMENT
BOUNDARY
CACHE
LA
POUDRE
RIVER
EAST MULBERRY STREET
R.O.W.
EXISTING EDGE OF ASPHALT (TYP)
10 EX.' DIRT TRACK
EXISTING DRIVE
20' ASPHALT ACCESS DRIVE
12' UTILITY ACCESS
(UTILITY PERSONNEL ONLY)
10' CONCRETE
MULTI MODAL PATH
9'-17' LANDSCAPE BUFFER
20' MIN SETBACK
SEE UTILITY PLAN DOCUMENTS SHT 3
50'
50'
R
=
2
5
'
R
=
2
5
'
20'
12' PHASE II UTILITY ACCESS
(UTILITY PERSONNEL ONLY)
20'
EXISTING VEGETATION EXISTING VEGETATION
HABITAT BUFFER ZONE
R=25'
10' FUTURE
MULTI MODAL PATH
(BY FC UTILITIES)
10' MULTI MODAL PATH
SEE UTILITY PLAN
DOCUMENTS SHT 3
115' MIN
BUFFER
20' SETBACK
7' HIGH FENCE
(SEE DETAIL ON SHT 4)
INVERTER PAD
TRANSFORMER PAD
PROPERTY LINE
RIVERSIDE AVENUE
EAST MULBERRY STREET
EXISTING RAILROAD TRACKS
MULBERRY WATER
RECLAMATION FACILITY
PROJECT DEVELOPMENT
BOUNDARY
CACHE
LA
POUDRE
RIVER
12
1
2
3
4
5
6
7
8
9 10
11
EXISTING EDGE OF ASPHALT (TYP)
SEE THIS SHEET FOR EXISTING TREE
INVENTORY NUMBER INFORMATION
6' TRAIL ALIGNMENT (BY OTHERS)
AG (TYP)
SOLAR ARRAY (TYP)
6' HIGH FENCE
(SEE DETAIL ON SHEET
#
)
PROPERTY LINE
EXISTING VEGETATION TO REMAIN
WITHIN SOLAR GARDEN
SEED MIX (TYP)
PROVIDE MULCHING
TO PROTECT EXISTING
GROUND AND ROOT SYSTEMS
TEMPORARY
ACCESS
EXPANSION
R50' TEMPORARY
ACCESS
EXPANSION
20'
5' EXPANSION
PROVIDE MULCHING
TO PROTECT EXISTING
GROUND AND ROOT SYSTEMS
EXISTING VEGETATION TO REMAIN
WITHIN SOLAR GARDEN
6' HIGH FENCE
(SEE DETAIL ON SHEET #) PRVIM (TYP)
EXISTING TREES TO REMAIN PER
EXISTING TREE INVENTORY TABLE
ON SHEET# (TYP)
PROPERTY LINE
SEE SHEET # FOR EXISTING TREE
INVENTORY NUMBER (TYP)
20' SETBACK (TYP) 20' SETBACK (TYP)
2' FENCE LINE
SETBACK (TYP)
20' (TYP) SOLAR MODULES (TYP)
DRIVEN STEEL SUPPORT COLUMNS
(SPACED 10' O.C. TYP)
6' - 8' HIGH FENCE
EXISTING GROUND VEGETATION TO REMAIN
PROPERTY LINE
6' - 8' HIGH FENCE
FILE
DATE
NO. DATE
DSGN DR
REVISION
CHK APVD
SHEET
DWG
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
0 SCALE
1437 LARIMER STREET
DENVER, COLORADO 80202
CLEAN ENERGY COLLECTIVE
RIVERSIDE COMMUNITY SOLAR GARDEN
FORT COLLINS, COLORADO
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF ENERTIA
CONSULTING GROUP AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF ENERTIA CONSULTING GROUP
OCTOBER 09, 2014
JSO MGB JSO JSO
TYPICAL SOLAR GARDEN SECTION VIEW (VIEW FROM RIVERSIDE AVENUE)
SCALE: 1" = 10'
TYPICAL DETAILS
PV ARRAY RACKING SYSTEM
NOT TO SCALE
MESH FENCING
WOOD POST (TYP)
7'
TYPICAL MESH FENCE DETAIL
NOT TO SCALE
7'
4'' PLACE CONCRETE
6'' MIN AROUND POST
DTL
1 OF 4
PLANNING DOCUMENTS
PLNG
SOLAR ARRAY (TYP)
CHOKECHERRY TO BE PLANTED
AS MITIGATION FOR TREE No. 3 REMOVAL
15
14
13
EXISTING VEGETATION TO REMAIN
WITHIN SOLAR GARDEN
EXISTING VEGETATION TO REMAIN
FILE
DATE
NO. DATE
DSGN DR
REVISION
CHK APVD
SHEET
DWG
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
0 SCALE
1437 LARIMER STREET
DENVER, COLORADO 80202
CLEAN ENERGY COLLECTIVE
RIVERSIDE COMMUNITY SOLAR GARDEN
FORT COLLINS, COLORADO
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF ENERTIA
CONSULTING GROUP AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF ENERTIA CONSULTING GROUP
OCTOBER 09, 2014
LANDSCAPE PLAN JSO MGB JSO JSO
PROPOSED LANDSCAPE BUFFER
GENERAL NOTES:
1. PLANTS SHALL BE DROUGHT RESISTANT AND WILL INITIALLY BE HAND WATERED TO ESTABLISHMENT FOR A
MINIMUM OF 3 YEARS. THE FREQUENCY AND AMOUNT OF IRRIGATION WATER APPLIED SHALL FOLLOW THE
RECOMMENDATION OF A QUALIFIED LANDSCAPE HORTICULTURIST THE QUALIFIED HORTICULTURIST SHALL
MAKE INSPECTIONS OF TREES AND SHRUBS DURING THE 3 YR ESTABLISHMENT PERIOD AND MAY ADVISE
INCREASED IRRIGATION FREQUENCY OR EXTRA YEARS OF IRRIGATION TO ENSURE ESTABLISHMENT.
2. MULCHING SHALL BE PLACED IN AREAS WHERE SOIL COMPACTION AND DAMAGE TO ROOT SYSTEMS IS
REQUIRED TO BE MINIMAL.
3. TRAIL ALIGNMENT IS FOR ILLUSTRATIVE PURPOSES ONLY AND IS SUBJECT TO CHANGE.
4. SEE THIS SHEET FOR ADDITIONAL NOTES, DETAILS, AND PLANT SCHEDULE.
3. THE PV ARRAYS SHALL BE INSTALLED AT EXISTING GRADE WITHOUT CLEARING OR GRUBBING OF
VEGETATION.
7. THE OBJECTIVE OF THE BUFFER ZONE IS TO PROTECT THE ECOLOGICAL CHARACTER OF THE NATURAL
HABITAT FROM THE IMPACTS OF THE ACTIVITIES ASSOCIATED WITH THE DEVELOPMENTS AND SHOULD BE
MAINTAINED AS NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE BUFFER ZONE.
8. IF AREA WITHIN THE HABITAT BUFFER ZONE BECOMES DISTURBED DURING CONSTRUCTION ACTIVITIES, THE
DEVELOPER SHALL RESEED THE AFFECTED AREA AND RESTORE NATIVE CONDITIONS SUFFICIENTLY.
HOWEVER, ANY FURTHER LANDSCAPING, PLANTING AND MAINTENANCE OF THAT AREA SHALL BE THE
RESPONSIBILITY OF FORT COLLINS UTILITIES DEPT.
9. BARE AREAS WITHIN THE HABITAT BUFFER ZONE SHALL BE RE-SEEDED. RE-SEEDING SHALL BE THE
RESPONSIBILITY OF THE FORT COLLINS UTILITY DEPARTMENT.
10' MULTI MODAL PATH
SEE UTILITY PLAN DOCUMENTS
SHT 3
PROPOSED FENCE
(SEE DETAIL ON SHT 3)
AG. (TYP)
LOW SEED MIX (TYP)
9'-17' LANDSCAPE BUFFER
HABITAT BUFFER ZONE
LANDSCAPE/PLANTING
(BY FC UTILITIES)
HABITAT BUFFER ZONE
LANDSCAPE/PLANTING
(BY FC UTILITIES)
115' MIN BUFFER
HABITAT
BUFFER ZONE
ARRAY (TYP)
PROPOSED ACCESS DRIVE
EXISTING DRIVE
EXISTING FENCE
20' SETBACK
TOP OF BANK
EX. ASPHALT
(TO REMAIN UNTIL
FUTURE RESORATION)
EXISTING TREES TO
REMAIN (TYP)
SEED NOTES:
1. SEED SHALL BE LABELED IN ACCORDANCE WITH THE U.S. DEPARTMENT OF AGRICULTURE, RULES AND
REGULATIONS AND FEDERAL SEED ACT. SEED SHALL BE EQUAL IN QUALITY TO THE STANDARDS FOR
"CERTIFIED SEED" AND SHALL BE FURNISHED IN SEALED, UNOPENED, STANDARD CONTAINERS. SEED
SHALL BE FRESH, CLEAN, PURE LIVE SEED WITH THE VARIETIES MIXED IN PROPORTIONS BY WEIGHT
SHOWN AND MEETING THE MINIMUM PERCENTAGES OF PURITY AND GERMINATION SPECIFIED.
2. SEED SHALL BE APPLIED AT A RATE SHOWN BY MIX. SEED SHALL PASS GOVERNMENT TEST OF
GERMINATION OF EIGHTY PERCENT (80%) AND FOR PURITY OF NINETY PERCENT (90%). THE PURE LIVE
SEED SHALL NOT BE LESS THAN SIXTY SEVEN ON ONE-HALF PERCENT (67.5%) FOR ANY ONE VARIETY, WITH
THE AVERAGE OF THE MIXTURE, NO LESS THAN SEVENTY TWO PERCENT (72%). ALL SEED SHALL BE FREE
OF POA ANNUA AND ALL NOXIOUS OBJECTIONABLE WEEDS WITH A MAXIMUM CROP OF ONE-TENTH
PERCENT (0.1%) AND MAXIMUM WEED OF ONE TENTH PERCENT (0.1%). IF SEED AVAILABLE ON THE MARKET
DOES NOT MEET THE MINIMUM PURITY AND GERMINATION PERCENTAGES SPECIFIED, THE CONTRACTOR
MUST COMPENSATE BY FURNISHING SUFFICIENT ADDITIONAL SEED TO EQUAL THE SPECIFIED PRODUCT.
3. SPREAD ORGANIC SOIL AMENDMENT MATERIALS, AT A RATE OF 2 C.Y. PER 1000 SQUARE FEET, EVENLY
OVER ENTIRE AREA AND THOROUGHLY INCORPORATE, BY MIXING, ROTOTILLING OR FINELY DISKING (MAX.
1" SIZE), TO A DEPTH OF SIX INCHES. ALL STONES, STICKS AND DEBRIS BROUGHT TO THE SURFACE SHALL
BE REMOVED FROM THE SITE PROPERLY DISPOSED OF BY THE CONTRACTOR, AT NO ADDITIONAL COST TO
THE OWNER. ALL SEED AREAS WILL THEN BE RAKED AND ROLLED TO THE DESIRED FINISHED GRADES WITH
GENTLY SLOPING SURFACES TO ADEQUATELY DRAIN ALL SURFACE WATER RUNOFF. THE FINISHED
SURFACE SHALL BE EVEN AND UNIFORM AND NO DIRT CLODS LARGER THAN ONE INCH (1") IN DIAMETER
SHALL APPEAR ON THE SURFACE. THE SOIL SURFACE SHALL BE SMOOTH, LOOSE AND OF FINE TEXTURE,
AND BE FLUSH WITH ALL PAVING EDGES.
4. CONTRACTOR SHALL USE APPROPRIATE MECHANICAL POWER (BRILLION SEEDER OR EQUAL) TO DRILL THE
SEED INTO THE SEEDBED WHEREVER POSSIBLE. SEED SHALL BE SOWN TO A DEPTH OF ONE-HALF INCH
(1
2"). DRILLING SHALL BE DONE IN 2 SEPARATE APPLICATIONS CROSSING THE AREA AT RIGHT ANGLES TO
ONE ANOTHER TO GURANTEE PROPER COVERAGE. ON SLOPING LAND, SEEDING OPERATIONS SHALL
FOLLOW THE GENERAL CONTOUR. AREAS TOO SMALL TO DRILL SEED MAY BE BROADCAST BY HAND AND
APPLICATION RATES SHALL BE DOUBLED. SEEDING OF ANY KIND WILL NOT BE PERMITTED WHEN WIND
VELOCITY IS SUCH AS TO PREVENT UNIFORM SEED DISTRIBUTION. NO APPLICATION SHALL TAKE PLACE
WITH THE PRESENCE OF FREE SURFACE WATER OR WHEN GROUND IS FROZEN OR CANNOT BE TILLED.
5. ALL SEED AREAS SHALL BE HYDRO MULCHED WITH A FIBROUS SLURRY MIXTURE
CONTAINING A TACKIFIER AGENT WITHIN 24 HOURS OF DRILLING OR BROADCAST AT A RATE OF 2,000
LBS. PER ACRE.
LANDSCAPE & SOIL PREPARATION NOTES:
1. ALL PLANT MATERIALS ARE TO BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION.
PLANT SPECIES MAY NOT BE SUBSTITUTED WITHOUT WRITTEN PERMISSION FROM THE LANDSCAPE
ARCHITECT.
2. ALL SHRUB BEDS ARE TO BE MULCHED WITH FIR FIBER MULCH AT A CONSISTENT DEPTH OF 4". SUBMIT
SAMPLE FOR APPROVAL PRIOR TO INSTALLATION.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE TO EXISTING UTILITIES, CURB
AND GUTTER, WALLS, OR WALKWAYS AND OTHER STRUCTURES THAT IS A RESULT OF THEIR WORK. THE
REPAIR OF SUCH DAMAGE WILL BE AT NO ADDITIONAL COST TO THE OWNER.
4. THE CONTRACTOR SHALL FINE GRADE ALL AREAS TO BE PLANTED. THE CONTRACTOR SHALL REMOVE
REQUIRED DEPTH OF SOIL ALONG WALKWAYS TO ACCOMMODATE SOD OR MULCH DEPTH.
5. TEST PRE-EXISTING SOIL IN LANDSCAPE AREA FOR MINERAL AND ORGANIC MATTER CONTENT TO
DETERMINE PROPER SOIL AMENDMENTS BASED ON RESULTS OF THE SOIL TEST.
6. PREPARE PLANTING BEDS PER SPECIFICATIONS.
7. NON-DYED SHREDDED CEDAR MULCH IS THE PREFERRED MULCH IN ALL AREAS VISIBLE FROM THE STREET.
8. INSTALL A CONTINUOUS COMMERCIAL GRADE WEED BARRIER AT PLANTING TIME, WHERE APPROPRIATE.
9. INSTALL A CONTINUOUS EDGER BETWEEN THE PLANT BED AND LAWN, AND BETWEEN WOOD AND ROCK
MULCH AREAS.
10. TREES PLANTED IN TURF AREAS SHOULD HAVE A MINIMUM 48" DIAMETER MULCH RING SURROUNDING THE
TRUNK. DO NOT PLACE MULCH DIRECTLY AGAINST THE TREE TRUNK.
11. PLANT TREES AND SHRUBS PER DETAILS AND SPECIFICATIONS.
12. FORM SOIL INTO A 3” TO 5” TALL WATERING RING (SAUCER) AROUND PLANTING AREA. THIS IS NOT
NECESSARY IN IRRIGATED TURF AREAS. APPLY 4” DEPTH OF SPECIFIED MULCH INSIDE WATERING RING.
TREE PROTECTION NOTES:
1. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A
FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE
DISTURBANCE.
2. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY
STANDARDS.
3. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED
EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN
HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF
(½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF
EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE.
4. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING
OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS,
OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A
TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.
5. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.
6. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR
LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF,"
RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION
(G)(3). THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET
APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH
AREAS BEING CLEARED.
7. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING
EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT
SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE
AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM
TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART ON THIS SHEET.
SEED MIX (TYP)
EXISTING BUILDING
(TO BE REMOVED)
EXISTING TRACKS
TOP OF BANK
EX. GATE
LOW SEED MIX (10,00 SF)
TREE DIAMETER AT
BREAT HEIGHT (INCHES)
AUGER DISTANCE FROM
FACE OF TREE (FEET)
0 - 2 1
3 - 4 2
5 - 9 5
10 - 14 10
15 - 19 12
OVER 19 15
AUGER-TREE CLEARANCE
HABITAT
BUFFER ZONE
LEGEND
ROCKY MOUNTAIN JUNIPER
TALL GRASSES
NATIVE SEED MIX
AUTUMN BRILLIANCE SERVICE
BERRY
CHOKE CHERRY
LOW GRASS SEED
E.G. CANADA WILDRYE OR PERENNIALS
WOOD ROSE, CURRANT, FALSE INDIGO BUSH, RABBIT
BRUSH, SERVICE BERRY, BOULDER RASPBERRY
(MIX RATIO TO BE THE RESPONSIBILITY OF FORT COLLINS)
PLANT LIST
TREE AND SHRUB PLANTING
FUTURE TRAIL
(BY FC UTILITES)
TYPE III BARRICADE
LSP
1 OF 3
PLANNING DOCUMENTS
PRVIM. (TYP)
W/ 3'' TO 5'' WATER SAUCER
W/ 3'' TO 5'' WATER SAUCER
NOTE: THE DISTANCE BETWEEN THE CONCRETE MULTI
MODAL PATH AND THE CENTER OF ANY SHRUB/TREE SHALL
BE A MIN OF 5'
MULTI MODAL PATH & LANDSCAPE
DESIGNATED AREA
PLNG
100YR FLOOD ZONE
500 YEAR
FLOOD ZONE
FLOOD ZONE LINE
100 YR FLOOD ZONE
100YR FLOOD ZONE
SEED MIX (TYP)
EXISTING BUILDING
(TO BE REMOVED)
SEE SHEET 3 FOR LANDSCAPE DETAILS
EXISTING CONCRETE
(TO BE REMOVED)
EXISTING CONCRETE
(TO BE REMOVED)
PROJECT DEVELOPMENT BOUNDARY
EX TREES
TO REMAIN
(TYP.)
EX. GAS LINE
(TO BE ABANDONED)
EX. ABANDONED
TELEPHONE
EXISTING
CONCRETE
EX. FENCE
CHAIN LINK W/BARED WIRE
(TO BE MODIFIED AS SHOWN)
TIE TO EXISTING FENCE
TIE TO EXISTING FENCE
EX. STORM INLET
EXISTING CONCRETE
(TO BE REMOVED)
GATE
EXISTING ASPHALT
(TO REMAIN UNTIL
FUTURE RESORATION)
TOP OF BANK
TOP OF BANK
EXISTING CONCRETE
(TO BE REMOVED)
EX. RETAINING WALL
(TO REMAIN)
SOLAR ARRAY
(TYP)
EX. GATE
TOP OF BANK
TYPE III BARRICADE
HABITAT BUFFER ZONE
LANDSCAPE/PLANTING
BY FC UTILITIES
(SEE SHT 3)
EXISTING
CONCRETE
WALK (TYP)
HABITAT BUFFER ZONE
LANDSCAPE/PLANTING
BY FC UTILITIES
(SEE SHT 3)
REMOVE AND REPLACE
ACCESS RAMP
(SEEUTILITY PLAN DOCUMENTS SHT 3)
7' HIGH FENCE
(SEE DETAIL ON SHT 4)
GRAVEL EMERGENCY TURNAROUND
MULTI MODAL PATH & LANDSCAPE DESIGNATED AREA
100YR FLOOD ZONE
500 YEAR
FLOOD ZONE
FLOOD ZONE LINE
100 YR FLOOD ZONE
100YR FLOOD ZONE
FILE
DATE
NO. DATE
DSGN DR
REVISION
CHK APVD
SHEET
DWG
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
0 SCALE
1437 LARIMER STREET
DENVER, COLORADO 80202
CLEAN ENERGY COLLECTIVE
RIVERSIDE COMMUNITY SOLAR GARDEN
FORT COLLINS, COLORADO
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF ENERTIA
CONSULTING GROUP AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF ENERTIA CONSULTING GROUP
OCTOBER 09, 2014
SITE PLAN JSO MGB JSO JSO
GENERAL NOTES:
1. THE SPECIFIED SOLAR PANELS, RACKING SYSTEM, AND INVERTER/TRNASFORMER ARE INTENDED TO ILLUSTRATE
*(1(5$/,1)250$7,21$%2877+(&20321(1762)7+(62/$5*$5'(1&20321(1767+$7$5(6,0,/$5,1
APPEARANCE AND FUNCTION MAY BE SUBSTITUTED FOR THE COMPONENTS SPECIFIED OR ILLUSTRATED ON THIS
6,7(3/$17+(/2&$7,212)7+($55$<6$1',19(57(560$<9$5<)520:+$7,6'(3,&7('217+,66,7(
PLAN, PROVIDED THE INSTALLED COMPONENTS MEET ALL REQUIRED SETBACKS.
2. LOCATION OF INVERTER PAD AND TRANSFORMER PAD MAY CHANGE. IF CHANGES ARE NECESSARY THE
EQUIPMENT SHALL BE PLACED IN SUCH A WAY SO THAT THEY ARE SCREENED AND ARE NOT VISIBLE FROM THE
PUBLIC RIGHT OF WAY.
3. THE PV ARRAYS SHALL BE INSTALLED AT EXISTING GRADE WITHOUT CLEARING OR GRUBBING OF VEGETATION.
4. THE PROPOSED MULTI MODAL PATH ALIGNMENT IS FOR ILLUSTRATIVE PURPOSES ONLY AND IS SUBJECT TO
CHANGE. TRAIL CONSTRUCTION WILL BE COORDINATED WITH FORT COLLINS UTILITIES DEPARTMENT WHO HOLDS
RESPONSIBILITY FOR THIS SITE IMPROVEMENT TO BE COMPLETED IN STAGES.
5. SEE LANDSCAPE PLANS FOR EXISTING TREE LOCATIONS.
6. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS & GUTTERS, DESTROYED, DAMAGED, OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT,
SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPERS EXPENSE PRIOR
TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST
CERTIFICATE OF OCCUPANCY.
7. THE OBJECTIVE OF THE BUFFER ZONE IS TO PROTECT THE ECOLOGICAL CHARACTER OF THE NATURAL HABITAT
FROM THE IMPACTS OF THE ACTIVITIES ASSOCIATED WITH THE DEVELOPMENTS AND SHOULD BE MAINTAINED AS
NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE
BUFFER ZONE.
8. IF AREA WITHIN THE HABITAT BUFFER ZONE BECOMES DISTURBED DURING CONSTRUCTION ACTIVITIES, THE
DEVELOPER SHALL RESEED THE AFFECTED AREA AND RESTORE NATIVE CONDITIONS SUFFICIENTLY. HOWEVER,
ANY FURTHER LANDSCAPING, PLANTING AND MAINTENANCE OF THAT AREA SHALL BE THE RESPONSIBILITY OF
FORT COLLINS UTILITIES DEPT.
9. THE VERTICAL CURB AND GUTTER ADJACENT TO THE ACCESS DRIVE SHALL REMAIN IN PLACE. GUTTER RAMPS
SHALL BE USED DURING CONSTRUCTION ACTIVITIES TO PREVENT THE CURB AND GUTTER FROM BECOMING
DAMAGED. OSP
1 OF 2
PLANNING DOCUMENTS
PLNG
INVERTERS ARE INTENDED TO ILLUSTRATE GENERAL
INFORMATION ABOUT THE COMPONENTS OF THE SOLAR
)$&,/,7<&20321(1767+$7$5(6,0,/$5,1$33($5$1&(
AND FUNCTION MAY BE SUBSTITUTED FOR THE COMPONENTS
63(&,),('25,//8675$7('217+,66,7(3/$17+(
LOCATION OF THE ARRAYS AND INVERTERS MAY VARY
SLIGHTLY FROM WHAT IS DEPICTED ON THIS SITE PLAN,
PROVIDED THE INSTALLED COMPONENTS MEET ALL
REQUIRED SETBACKS.
2. THE ENGINEER WHO HAS PREPARED THESE PLANS, BY
EXECUTION AND/OR SEAL HEREOF, DOES HEREBY AFFIRM
RESPONSIBILITY TO THE LOCAL ENTITY, AS BENEFICIARY OF
SAID ENGINEER'S WORK, FOR ANY ERRORS AND OMISSIONS
CONTAINED IN THESE PLANS, AND APPROVAL OF THESE
PLANS BY THE LOCAL ENTITY ENGINEER SHALL NOT RELIEVE
THE ENGINEER WHO HAS PREPARED THESE PLANS OF ALL
SUCH RESPONSIBILITY. FURTHER, TO THE EXTENT
PERMITTED BY LAW, THE ENGINEER HEREBY AGREES TO
HOLD HARMLESS AND INDEMNIFY THE LOCAL ENTITY, AND ITS
OFFICERS AND EMPLOYEES, FROM AND AGAINST ALL
LIABILITIES, CLAIMS, AND DEMANDS WHICH MAY ARISE FROM
ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS.
OVERALL SITE AREA
SCALE 1" = 100'
APPLICANT
CLEAN ENERGY COLLECTIVE
3005 CENTER GREEN DRIVE, SUITE 205
BOULDER, CO 80301
CONTACT: MICHELLE ZIMMERMAN
(303) 881-3087
ENGINEER
ENERTIA CONSULTING GROUP, LLC
1437 LARIMER STREET
DENVER, COLORADO 80202
CONTACT: SEAN O'HEARN, PE, PG
(303) 473-3131
SURVEYOR
PRECISION SURVEY
9145 EAST KENYON AVENUE #101
DENVER, COLORADO 80237
CONTACT: CHRIS JULIANA, PLS
(303) 825-4822
VICINITY MAP
SCALE 1" = 2000'±
CVR
1 OF 1
SITE
GENERAL LEGEND
PROJECT DEVELOPMENT BOUNDARY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED FENCE
SETBACK LINE
RIGHT-OF-WAY
PROPERTY LINE
EXISTING UNDERGROUND ELECTRIC
EXISTING UNDERGROUND TELECOMMUNICATIONS
EXISTING GAS LINE UTILITY
EXISTING DRIVE
PROPOSED ACCESS
PLANNING DOCUMENTS
PROPOSED FENCE
MULTI MODAL PATH & LANDSCAPE
DESIGNATED AREA
ENGINEER CERTIFICATION
I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE
PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH
ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO
STANDARDS AND STATUTES, RESPECTIVELY; AND THAT I AM FULLY
RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN, REVISIONS, AND
RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS.
DISCLAIMER STATEMENT:
THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY
FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY
RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE
LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR
ACCURACY AND CORRECTNESS OF THE CALCULATIONS.
FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT
QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL
QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE
CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL
RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL
QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED
DURING THE CONSTRUCTION PHASE.
DATE:
PLNG