HomeMy WebLinkAboutZIEGLER-HARVEST PARK - FDP - FDP140022 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLAN (5)X SHEET 3 BLUEGRASS SOD: SOD VARIETY TO BE QUALITY DROUGHT TOLERANT BLEND. SUBMIT SPECIFICATIONS PRIOR TO INSTALLATION. SOIL PREPARATION: ALL LANDSCAPED AREAS SHALL CONSIST OF THE ADDITION OF THREE CUBIC YARDS OF PREMIUM 3 BY A-1 ORGANICS OR APPROVED EQUAL PER 1000 SQUARE FEET OF LANDSCAPED AREA TO BE TILLED INTO THE TOP 6" OF EXISTING SOIL UNLESS SOILS TESTING INDICATES A MORE APPROPRIATE AMENDMENT. TREE AND SHRUB PITS SHALL BE BACKFILLED USING A MIXTURE OF ONE-THIRD EXISTING SITE SOIL, ONE-THIRD TOPSOIL AND ONE-THIRD ORGANIC MATTER. GEOTEXTILE FABRIC: MIRIFI GEOTEXTILE FABRIC TO BE USED IN COBBLE, DECORATIVE STONE, PEA GRAVEL AND WOOD MULCH AREAS TO PREVENT WEED GROWTH. IN AREAS WHERE PERRENIAL PLANTINGS ARE NUMEROUS FABRIC MAY BE OMITTED. SHRUB BEDS: MULCH AREAS HAS DESIGNATED ON LANDSCAPE PLANS. MULCHES INCLUDE 3"-4" RIVER COBBLE, PEA GRAVEL, DECORATIVE STONE MULCH, AND SHREDDED REDWOOD FIBER BARK MULCH (GORILLA HAIR). MULCH SHALL BE AT LEAST 2"-3" LAYER WHEN INSTALLED. TREE PLANTING RINGS IN IRRIGATED TURF AREAS: MULCH ALL SOIL PLANTING RINGS OF DECIDUOUS AND CONIFEROUS TREES WITH A 3" LAYER OF SHREDDED REDWOOD FIBER BARK MULCH (GORILLA HAIR). STEEL EDGER CONSTRUCTION: STEEL EDGER TO BE 3 16"X4"X16" ROLLTOP STEEL EDGING LAYOUT STEEL EDGER IN LOCATIONS SHOWN ON PLANS AND RECEIVE REVIEW OF OWNER PRIOR TO INSTALLATION. LOCATE BY SCALING OFF OF THE PLAN. INSTALL PLUMB WITH GRADES MAINTAINING A MINIMUM CONSTANT HEIGHT OF ONE INCH ABOVE ADJACENT TURF AREAS. INSTALL USING STRAIGHT LINES AND SMOOTH CURVES. STAKE STEEL EDGER USING PINS AT TWO FOOT ON CENTER. PROVIDE DRAINAGE HOLES AT SUFFICIENT INTERVALS TO ALLOW EXCESS WATER TO DRAIN AWAY. PBSI NATIVE PRAIRIE MIX $9 PER PLS LB 1lb/1000 SF 23% BLUE GAMMA 10%BUFFALO GRASS (15 lbs/ACRE 20% GREEN NEEDLE GRASS 20% SIDEOATS GRAMA 25% WESTERN WHEAT GRASS 2% SAND DROPSEED DRILLED SEED RATE AT A RATE OF 15-2O LBS. PER ACRE. THIS MIX IS EASY TO MAINTAIN, EASY TO REMOVE IF NECESSARY, CAN BE CUT LOW, CAN HANDLE SOME SHADE AND NEEDS VERY LITTLE IRRIGATION ONCE ESTABLISHED. PAWNEE SEED CO. 605 25TH STREET, GREELEY, COLORADO 970-356-7026 STANDARD GUYING SYSTEM: MIN. 6' LONG HEAVY DUTY T-BAR STEEL POST STAKES WITH WHITE T-POST, WITH SAFETY CAPS AND WITH 17 GAUGE GALVANIZED STEEL WIRE GUYS SECURED TO TREE WITH CANVAS STRAP ABOVE FIRST BRANCH. WIRE TO BE TAUT BUT NOT OVER- TIGHT, FLAG WIRE WITH WHITE PLASTIC FLAGGING TAPE. CONIFERS TO HAVE 2 STAKES FOR TREES 6' AND LESS, 3 STAKES FOR TREES ABOVE 6'. DECIDUOUS TREES TO HAVE 2 STAKES FOR TREES 2-1/2" CAL. AND LESS, 3 STAKES ABOVE 2-1/2" CAL. ONE STAKE ALWAYS IN DIRECTION OF PREVAILING WINDS. REMOVE STAKES & GUYS AFTER 1 YEAR. WRAP TRUNK FROM GROUND LEVEL TO SECOND BRANCH WITH 4" KRAFT TYPE TREE WRAP. SECURE ENDS WITH FLEXIBLE TAPE. PRUNE AS DIRECTED BY OWNER'S REPRESENTATIVE. DO NOT PRUNE OR DAMAGE CENTRAL LEADER. PREPARED BACKFILL MIXTURE: ALTERNATE CONIFER GUYING SYSTEM: EQUALLY SPACED 30" STEEL STAKES WITH WHITE TOPS, SET FLUSH WITH GRADE. GUY TO MID-POINT OF TREE & FLAG WIRE WITH 1/2" DIAMETER WHITE PVC PIPE. REMOVE BOTTOM 1/3 OF WIRE BASKET. SET TREE IN PIT TO PROPER GRADE AND PLUMB. REMOVE REMAINING WIRE & TWINE. IF PLASTIC OR TREATED BURLAP, REMOVE AS MUCH AS POSSIBLE & BACKFILL. IF REGULAR BURLAP, BACKFILL 2/3 OF PIT, REMOVE TOP 1/3 OF BURLAP & COMPLETE BACKFILL. 4" DEEP WOOD CHIP MULCH FLUSH WITH SOD AT EDGE. & TO BE KEPT 2" FROM TRUNK. LEAVE BERM & MULCH IN NON-IRRIGATED AREAS & IN AREAS ONLY IRRIGATED BY DRIP SYSTEMS AFTER DRYLAND GRASS ESTABLISHMENT PERIOD. REMOVE BERM AFTER TWO THOROUGH WATERINGS IN IRRIGATED AREAS AND MULCH. BERM IS TEMPORARY IN IRRIGATED AREAS. MODIFY IF SOIL CONDITIONS WARRANT. INSTALL A 5" HIGH BERM AROUND TREES TO CREATE A WATERING BASIN. SET ROOT BALL OF ALL TREES 4" ABOVE GRADE IN IRRIGATED AREAS AND AT GRADE TO 2" ABOVE GRADE IN NON-IRRIGATED AREAS. NOTE: 1. ONE PART SOIL AMENDMENT 2. TWO PARTS TOPSOIL. 3. THREE PARTS NATIVE SOIL. 4. SUPERPHOSPHATE AMENDMENT. 5. MATERIALS TO BE THOROUGHLY BLENDED. DIAMETER 2x'S BALL WIDTH UNDISTURBED SOIL GENERAL NOTES PLANTING NOTES NATIVE GRASS MIX SHRUB PLANTING DETAIL TREE PLANTING DETAIL PREPARED BACKFILL MIXTURE: 1. ONE PART SOIL AMENDMENT 2. TWO PARTS TOPSOIL. 3. THREE PARTS NATIVE SOIL. 4. SUPERPHOSPHATE AMENDMENT. 5. MATERIALS TO BE THOROUGHLY BLENDED. PRUNE DEAD OR DAMAGED BRANCHES PRIOR TO PLANTING. IF FORM IS COMPROMISED BY PRUNING, REPLACE SHRUB. SPACE PLANTS AND SET PLUMB FOR BEST EFFECT. MOUND COMPACTED BACKFILL UNDER ROOTBALL OR SET ON UNDISTURBED SOIL. SPLIT BOTTOM 1/2 OF BALL. SPREAD AND PLANT. 3" DEEP WOOD CHIP MULCH INSIDE SAUCER, ON GEO-TEXTILE WEED BARRIER. BUILD A 4" BASIN AROUND PIT IN NON-IRRIGATED AREAS ONLY. SET SHRUB PLUMB. TOP OF ROOT BALL TO MATCH FINISH GRADE -DECIDUOUS 2" ABOVE FINISH GRADE - CONIFEROUS REMOVE ALL CONTAINERS, BASKETS, WIRE ETC. FROM ROOTBALL 2" DIAMETER 2X'S BALL WIDTH WATER BUDGET CHART HYDROZONE PLAN 15' 0' 30' 60' NORTH GENERAL NOTES DP INVESTMENT GROUP, LLC 4640 WITHERS DRIVE FORT COLLINS, CO 80524 FORT COLLINS, COLORADO LANDSCAPE DETAILS DATE: SEPTEMBER 17, 2014 FINAL DEVELOPMENT PLAN LOT 2, HARVEST PARK - ZIEGLER MIXED USE 1. ALL WORK SHALL CONFORM TO LOCAL CITY CODES. ALL LANDSCAPING AND PLANTS TO BE LOCATED NOT TO INTERFERE WITH EXISTING OR PROPOSED UTILITIES. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES, LINES AND STRUCTURES PRIOR TO EXCAVATION OR TRENCHING. DAMAGE TO THESE UTILITIES SHALL BE REPAIRED BY THE CONTRACTOR AT NOT COST TO THE OWNER OR LANDSCAPE ARCHITECT. 2. ALL PLANT MATERIALS SHALL BE IN ACCORDANCE WITH AAN (AMERICAN ASSOCIATION OF NURSERYMEN) SPECIFICATIONS FOR NUMBER ONE GRADE. 3. PLANT QUANTITIES SHOWN ARE FOR INFORMATION PURPOSES ONLY, CONTRACTOR TO VERIFY ALL QUANTITIES. 4. ALL TREE AND SHRUB LOCATIONS SHALL BE STAKED BY CONTRACTOR AND APPROVED BY LANDSCAPE ARCHITECT. 5. PLANT SUBSTITUTIONS SHALL BE STAKED BY CONTRACTOR AND APPROVED BY LANDSCAPE ARCHITECT. 6. PLANTS SHALL BE INSTALLED IMMEDIATELY UPON DELIVERY TO SITE. IF THIS IS NOT POSSIBLE. PLANTS SHALL BE HEELED IN AND WATERED TO PREVENT DEHYDRATION. 7. 6" SOIL MIX CONSISTING OF 20% ORGANIC COMPOST, 20% ORGANIC PEAT & 60% TOPSOIL SHALL BE TILLED IN TO ALL SHRUB BEDS. 4" OF SAME SHALL BE TILLED INTO ALL SEEDED AREAS. 8. DESIGN OF IRRIGATION SYSTEMS SHOULD AVOID OVERSPRAY ONTO NON-PLANTED AND IMPERVIOUS SURFACES. 9. ALL IRRIGATION SYSTEMS SHALL BE MAINTAINED IN GOOD WORKING CONDITION. 10. ALL LANDSCAPING SHALL BE INSTALLED CONSISTENT WITH XERISCAPE STANDARDS FOR INSTALLATION, SOIL PREPARATION AND IRRIGATION. 11. ALL LANDSCAPING SHALL MEET UTILITY CLEARANCE REQUIREMENTS STIPULATED BY THE CITY. 12. SPACING OF TREES WILL BE SUBJECT TO POSITION ADJUSTMENT TO ACCOMMODATE DRIVEWAY CURBCUTS; STORM SEWER, WATER, AND SANITARY SEWER FACILITIES; ELECTRICAL APPURTENANCES; AND ANY OTHER FIXED IMPROVEMENTS. 13. LOCATION OF TREES AND SHRUBS MAY BE SITE ADJUSTED. FINAL LOCATIONS TO BE DETERMINED IN THE FIELD BY THE LANDSCAPE ARCHITECT. THE CONTRACTOR SHALL CALL FOR ALL UTILITY LOCATES AND FIELD VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. 14. TREES SHALL NOT BE PLANTED CLOSER THAN 4 FEET ON CENTER TO ANY GAS OR ELECTRIC LINE AND NO CLOSER THAN 10 FEET ON CENTER TO ANY WATER OR SEWER LINE. SHRUBS SHALL NOT BE PLANTED CLOSER THAN 4 FEET ON CENTER TO ANY WATER OR SEWER LINE. TREE PLANTING SHALL BE COORDINATED WITH PUBLIC SERVICE COMPANY. LOCATIONS OF ALL UTILITIES SHALL BE VERIFIED IN THE FIELD PRIOR TO PLANTING. A HORIZONTAL DISTANCE OF 40 FEET ON CENTER BETWEEN STREET TREES AND STREET LIGHTS SHALL BMAINTAINED.NO LANDSCAPING CAN BE LOCATED WITHIN 8' OF THE FRONT / BACK OF A TRANSFORMER OR WITHIN 3' OF THE SIDES OF A TRANSFORMER. 20' BETWEEN SHADE AND/OR ORNAMENTAL TREES AND TRAFFIC CONTROL SIGNS AND DEVICES. 10' BETWEEN TRESS AND WATER OR SEWER MAINS. 6' BETWEEN TREES AND WATER OR SEWER SERVICE LINES 15. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED, OR REMOVED ON THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND ANY OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT MAY RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON THE CERTIFICATE OF OCCUPANCY. 16. THE DEVELOPER SHALL CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENTS. ALL TREES NEED TO HAVE BEEN INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF THE STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE. FAILURE TO OBTAIN APPROVAL BY THE CITY FORESTER FOR THE STREET TREES IN A PHASE SHALL RESULT IN A HOLD ON THE CERTIFICATE OF OCCUPANCY FOR FUTURE PHASES OF THE DEVELOPMENTS. 17. ALL LANDSCAPE AREAS WITHIN THE SITE SHALL BE IRRIGATED WITH AN AUTOMATIC UNDERGROUND IRRIGATION SYSTEM. AN IRRIGATION PLAN WILL BE REQUIRED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. 18. ALL TURF AREAS (NOT INCLUDING DRY LAND TURF AREAS) TO BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES TO BE IRRIGATED WITH AN AUTOMATIC DRIP IRRIGATION SYSTEM OR ACCEPTABLE ALTERNATIVE. 19. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER ZONE. 20. TREES SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP SYSTEM OR EQUIVALENT. 21. THE WATER BASIN RIDGE FOR TREES IN DRY LAND AREAS TO BE AT LEAST 6 INCHES HIGHER TO ALLOW FOR SETTLING OF SOIL. 22. MITIGATION TREES SHOULD BE UPSIZED AS FOLLOWS AND RECORDED IN THE PLANT LIST. CANOPY SHADE TREES CURRENTLY SHOWN AS MITIGATION TREES ARE AT 2.5 INCH CALIPER. - CANOPY SHADE TREES 3.0 INCH CALIPER - ORNAMENTAL TREES 2.5 INCH CALIPER - EVERGREEN TREES 8 FEET IN HEIGHT ARCHITECTURE WEST, LLC 160 PALMER DRIVE FORT COLLINS, CO 80525