HomeMy WebLinkAboutAVONDALE COTTAGES - PDP - PDP140003 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANS1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
COVER SHEET
04/23/14
N/A
N/A
JTC
RA
1 of 4
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
UTILITY PLANS FOR
AVONDALE COTTAGES
A REPLAT OF TRACT L, RIDGEWOOD HILLS P.U.D., FIRST FILING, LOCATED IN THE NORTHEAST
QUARTER OF SECTION 14, TOWNSHIP 6 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN,
CITY OF FORT COLLINS,
COUNTY OF LARIMER, STATE OF COLORADO
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
GENERAL NOTES
04/23/14
N/A
N/A
JTC
RA
2 of 4
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
PRELIMINARY
NOT FOR CONSTRUCTION
LOT 2
LOT 1
LOT 5
LOT 4
LOT 3
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
TRACT K
WEST TRILBY ROAD
AVONDALE ROAD
LOT 2
LOT 1
LOT 5
LOT 4
LOT 3
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
PRIVATE
DRIVE
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
GRADING, DRAINAGE
& EROSION CONTROL PLAN
AVONDALE COTTAGES
04/23/14
1"=X'
N/A
JTC
RA
3 of 4
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
WEST TRILBY ROAD
AVONDALE ROAD
LOT 2
LOT 1
LOT 5
LOT 4
LOT 3
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
TRACT K
PRIVATE
DRIVE
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
UTILITY PLAN
04/23/14
1"=20'
N/A
JTC
RA
4 of 4
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
0
20'
20 10 20 40
SCALE: 1" =
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
NOTES:
1. BURIED UTILITIES AND OR PIPE LINES ARE SHOWN PER VISIBLE SURFACE EVIDENCE
AND AS-BUILT DRAWINGS OF THE CONSTRUCTED UTILITY LINES. THE CONTRACTOR
SHALL VERIFY THE DEPTH AND LOCATION OF ALL EXISTING UTILITY CONNECTIONS
AND CROSSINGS PRIOR TO ANY CONSTRUCTION. IF A CONFLICT OCCURS BETWEEN
EXISTING AND PROPOSED UTILITIES AND/OR DESIGN MODIFICATION IS REQUIRED,
THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE
DESIGN. THE ENGINEER AND/OR THE SURVEYOR OF RECORD SHALL NOT BE LIABLE
FOR THE LOCATION OF OR THE FAILURE TO NOTE THE LOCATION OF NON-VISIBLE
UTILITIES.
2. SITE CONTRACTOR SHALL TERMINATE UTILITY SERVICES 5-FEET FROM BUILDING
UNLESS OTHERWISE NOTED. SITE CONTRACTOR SHALL COORDINATE EXACT
LOCATIONS OF BUILDING UTILITIES WITH ARCHITECTURAL DRAWINGS.
3. ALL STORM SEWER, POWER AND OTHER "DRY" UTILITY INSTALLATIONS, SHALL
CONFORM TO THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS
CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE LOCAL ENGINEER.
4. ALL WATER LINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS -
LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS CURRENT TO THE
DATE OF CONSTRUCTION.
5. ALL SANITARY SEWER LINE CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT
COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS CURRENT TO
THE DATE OF CONSTRUCTION.
6. STORM SEWER PIPE SHALL BE RCP OR HDPE WITH WATER TIGHT JOINTS AS
SPECIFIED ON THE PLAN. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF
FORT COLLINS.
7. LENGTH OF PIPE IS MEASURED FROM CENTER OF STRUCTURE TO CENTER OF
STRUCTURE AND INCLUDES THE FLARED END SECTION.
8. WATER MAINS SHALL BE PVC (C-900) AS SPECIFIED BY THE FORT COLLINS -
LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS.
9. ALL WATER SERVICES SHALL BE INSTALLED AT A MINIMUM OF 5-FEET BELOW
FINISHED FLOOR ELEVATION AND SHALL BE PVC (C-900) UNLESS OTHERWISE
NOTED.
10. ALL SANITARY SEWER PIPE SHALL BE PVC (SDR 35) UNLESS OTHERWISE NOTED ON
THE PLAN. SEWER PIPE SHALL BE AS SPECIFIED BY THE SOUTH FORT COLLINS
SANITATION DISTRICT STANDARDS AND SPECIFICATIONS.
11. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATION DETAILS OF GAS METERS,
ELECTRIC METERS, AND TELEPHONE TERMINALS.
12. LIMITS OF STREET CUT SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY CITY ENGINEER INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
13. CITY OF FORT COLLINS LIGHT & POWER (L&P) SHALL INSTALL PRIMARY LINE FROM
CONNECTION POINT TO ELECTRIC VAULT, SECONDARY LINES FROM VAULT TO
METER, AND BUILDING METER. CONTRACTOR SHALL COORDINATE WITH FORT
COLLINS METER GROUP FOR METER LOCATION. CONTACT CITY OF FORT COLLINS
LIGHT & POWER FOR THEIR CURRENT REQUIREMENTS.
PRELIMINARY
NOT FOR CONSTRUCTION
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
LEGEND
SILT FENCE
INLET PROTECTION
(REFER TO DETAIL)
CONSTRUCTION ENTRANCE
NOTES:
1. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM
ELEVATIONS REQUIRED FOR THE PROTECTION FROM THE 100-YR STORM.
2. ALL SANITARY SEWER, STORM SEWER, AND WATER LINE CONSTRUCTION, AS
WELL AS POWER AND OTHER "DRY" UTILITY INSTALLATIONS, SHALL CONFORM
TO THE LOCAL ENTITY STANDARDS AND SPECIFICATIONS CURRENT AT THE
DATE OF APPROVAL OF THE PLANS BY THE LOCAL ENGINEER.
3. PROPOSED EASEMENTS ARE SHOWN AND WILL BE DEDICATED WITH THE PLAT.
EASEMENTS ARE LABELED ON THE UTILITY PLAN.
4. THE DRIVES WITHIN THE SITE WILL BE PRIVATELY OWNED AND MAINTAINED.
THERE WILL BE NO PUBLIC MAINTENANCE OF THE DRIVE.
5. OFFSITE GRADING IS LIMITED TO AREAS COVERED BY EXISTING DRAINAGE
AND/OR UTILITY EASEMENTS FOR THE PURPOSE OF UTILITY OR DRAINAGE
CONNECTIONS, UNLESS OTHERWISE NOTED.
6. SEE LANDSCAPE PLAN FOR REVEGETATION METHODS AND DETAILS. DURING
CONSTRUCTION, ANY SOIL DISTURBED AND NOT UNDER ACTIVE
CONSTRUCTION SHALL BE SEEDED AND MULCHED PER LCUASS STANDARDS.
7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY CITY ENGINEER INSPECTOR. ALL REPAIRS TO BE
IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS
8. A SEPARATE BUILDING PERMIT IS REQUIRED FOR ALL RETAINING WALLS
GREATER THAN 2 FEET HIGH.
PRELIMINARY
NOT FOR CONSTRUCTION
0
20'
20 10 20 40
SCALE: 1" =
DRAINAGE ARROW
APRIL 2014
UTILITY CONTACTS:
INDEMNIFICATION STATEMENT:
THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR
CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY
THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE
LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE
CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT
QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES
REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON
AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL
ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE
REQUIRED DURING THE CONSTRUCTION PHASE.
CITY OF FORT COLLINS BENCHMARK #38-94
AZIMUTH MARK (3 1/4" ALUMINUM CAP) ON THE NORTH SIDE OF TRILBY RD. 1/2
MILE WEST OF COLLEGE AVE. AT THE SOUTHWEST CORNER OF 508 WEST
TRILBY RD. (GOOD SAMARITAN RETIREMENT CENTER). ALSO 5.5 FT WEST OF A
POWERPOLE AND 24.5 FT SOUTH OF A WOOD FENCE.
ELEV=5093.76 NAVD 88
CITY OF FORT COLLINS BENCHMARK #47-94
ON THE EAST SIDE OF SOUTH COLLEGE AVE.. AT ROBERT BENSON LAKE, ON
TOP OF THE SOUTHEAST CORNER OF AN INLET.
ELEV=5022.72 NAVD88
BASIS OF BEARINGS
ASSUMING THE NORTH LINE OF THE NORTHEAST QUARTER OF SECTION 14,
715:$6%($5,1*1257+
($67%(,1*$*5,'%($5,1*2)
THE COLORADO STATE PLANE COORDINATE SYSTEM, NORTH ZONE, NORTH
AMERICAN DATUM 1983/2007, A DISTANCE OF 2562.81 FEET WITH ALL OTHER
BEARINGS CONTAINED HEREIN RELATIVE THERETO.
PROPOSED STREET LIGHT
PROPOSED STORM SEWER
EXISTING SANITARY SEWER MAIN
PROPOSED TELEPHONE LINE
EXISTING GAS
EXISTING STORM SEWER
EXISTING WATER MAIN
EXISTING MANHOLE
PROPOSED STORM INLET
LEGEND
PROPOSED CONCRETE
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION
PROPOSED MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
EXISTING UTILITY POLE
EXISTING GUY WIRE
PROPOSED GAS
EXISTING ELECTRIC LINE PROPOSED ELECTRIC LINE
EXISTING TELEPHONE LINE
EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT
EXISTING WATER VALVE
PROPOSED SANITARY SEWER MAIN
PROPOSED WATER MAIN
EXISTING CONCRETE
EXISTING FLOWLINE, CURB & GUTTER PROPOSED FLOWLINE, CURB & GUTTER
PROPOSED FENCE
LIMITS OF CONSTRUCTION
EXISTING OVERHEAD UTILITY
EXISTING STORM SEWER INLET
PROPOSED WATER VALVE
PROPOSED MANHOLE
PROPOSED UTILITY POLE
EXISTING STREET LIGHT
PROPOSED SWALE
PROPOSED DIRECTION OF OVERLAND FLOW
PROPOSED EMERGENCY OVERFLOW ROUTE
EXISTING FIBER OPTIC LINE
PROPOSED HANDICAP RAMP
EXISTING OVERHEAD ELECTRIC LINE
EXISTING OVERHEAD TELEPHONE LINE
PROPOSED OVERHEAD ELECTRIC LINE
PROPOSED FIBER OPTIC LINE
PROPOSED OVERHEAD TELEPHONE LINE
EXISTING FENCE
PROPOSED WATER SERVICE W/
PROPOSED SANITARY SEWER SERVICE
CURB STOP AND METER PIT
W/ CLEANOUT
PROPOSED OVERHEAD UTILITY
PROPOSED LIGHT POLES
AD ALGEBRAIC DIFFERENCE
AE ACCESS EASEMENT
ARV AIR RELEASE VALVE
BOV BLOW OFF VALVE
BOS BOTTOM OF STEP
BW BOTTOM OF WALL
CL CENTERLINE
CMP CORRUGATED METAL PIPE
CO CLEAN OUT
DE DRAINAGE EASEMENT
E ELECTRIC
EAE EMERGENCY ACCESS EASEMENT
EG EXISTING GROUND
EL ELEVATION
EOA EDGE OF ASPHALT
EX EXISTING
ESMT EASEMENT
F FIRE LINE
FES FLARED END SECTION
FG FINISHED GRADE
FH FIRE HYDRANT
FL FLOWLINE
FO FIBER OPTIC
G GAS
GB GRADE BREAK
GF GARAGE FLOOR
GV GATE VALVE
HDPE HIGH DENSITY POLYETHYLENE
HP HIGH POINT
FF FINISHED FLOOR
FH FIRE HYDRANT
IE IRRIGATION EASEMENT
INV INVERT
IRR IRRIGATION
LF LINEAR FEET
LP LOW POINT
LT LEFT
MH MANHOLE
OHE OVERHEAD ELECTRIC
OHT OVERHEAD TELEPHONE
OHU OVERHEAD UTILITY
PE PEDESTRIAN EASEMENT
PC POINT OF CURVATURE
PCR POINT OF CURB RETURN
PI POINT OF INTERSECTION
PT POINT OF TANGENCY
PVC POLYVINYL CHLORIDE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
ROW RIGHT-OF-WAY
RT RIGHT
SS SANITARY SEWER
STA STATION
SD STORM DRAIN PIPE
SDMH STORM DRAIN MANHOLE
SMH SANITARY SEWER MANHOLE
T TELEPHONE
TB THRUST BLOCK
TBC TOP BACK OF CURB
TC TOP OF CONCRETE
TF TOP OF FOUNDATION
TOS TOP OF STEP
TW TOP OF WALL
TYP TYPICAL
UE UTILITY EASEMENT
VCP VITRIFIED CLAY PIPE
VPC VERTICAL POINT OF CURVATURE
VPI VERTICAL POINT OF INTERSECTION
VPT VERTICAL POINT OF TANGENCY
W WATERLINE
ABBREVIATION LIST
vicinity map
Scale: 1" = 1000'
I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE
PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH
ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO
STANDARDS AND STATUTES, RESPECTIVELY, AND THAT I AM FULLY
RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN, REVISIONS AND
RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS.
ROBERT ALMIRALL
P.E. NO. 33441
All changes, addendums, additions, deletions and
modifications to these drawings must be approved,
in writing, by the Fort Collins-Loveland
Water District and the South Fort Collins Sanitation District.
Mr. Terry Farrill, P.E., District Engineer Date
Mr. Michael D. DiTullio, Manager Date
FORT COLLINS - LOVELAND
WATER DISTRICT
SOUTH FORT COLLINS
SANITATION DISTRICT
OWNER / DEVELOPER
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
Ph. 970.223.4522
ENGINEER
Interwest Consulting Group
1218 W. Ash, Suite C
Windsor, Colorado 80550
Ph. 970.674.3300
PLANNER
Vignette Studios
P.O. Box 1889
Fort Collins, Colorado
80522
Ph. 970.472.9125
SURVEYOR
King Surveyors
650 Garden Drive
Windsor, Colorado 80550
Ph. 970.686.5011
FORT COLLINS UTILITIES
700 Wood Street
Fort Collins, Colorado 80522
STORMWATER
Wes Lamarque
Ph. 970.416.2418
LIGHT & POWER
Doug Martine
Ph. 970.221.6700
NATURAL GAS
Xcel Energy
1901 E. Horsetooth Road
Fort Collins, Colorado 80525
Contact: Stephanie Rich
Ph. 970.225.7828
WATER/WASTEWATER
Fort Collins-Loveland Water District
South Fort Collins Sanitation District
5051 Snead Drive
Fort Collins, Colorado 80525
Contact: Terry Farrill
Ph. 970.226.3104
TELEPHONE SERVICE
Century Link (Qwest)
3351 Eastbrook Drive
Fort Collins, Colorado 80525
Contact: Bill Johnson
Ph. 970.377.6401
INDEX OF SHEETS
Sheet No. Description of Sheets
1 COVER SHEET
2 GENERAL NOTES
3 GRADING, DRAINAGE & EROSION CONTROL PLAN
4 UTILITY PLAN
PRELIMINARY
NOT FOR CONSTRUCTION