Loading...
HomeMy WebLinkAboutRIDGEWOOD HILLS RESIDENCES, 4TH FILING - FDP - FDP130052 - PLANS - UTILITY PLANSS. SHIELDS STREET STATE HIGHWAY 287 (COLLEGE AVE) E. TRILBY ROAD E. COUNTY ROAD 32 (CARPENTER ROAD) S. LEMAY AVE AVONDALE ROAD PEYTON DRIVE EGYPTIAN DRIVE PROJECT SITE TRIANGLE DRIVE THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com TITLE SHEET 1 1 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL NORTH FINAL DEVELOPMENT PLAN VICINITY MAP SCALE: 1"=1000' SURVEYOR: ENGINEER: PLANNER: OWNER/APPLICANT: LEGAL DESCRIPTION RIDGEWOOD HILLS - FOURTH FILING PARCELS OF LAND LOCATED IN SECTION 14, T.6N., R.69W., OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO AND BEING PARTICULARLY DESCRIBED AS FOLLOWS: TRACT N AND TRACT T OF RIDGEWOOD HILLS P.U.D., THIRD FILING ACCORDING TO THE RECORDED PLAT THEREOF AS RECORDED BY THE LARIMER COUNTY CLERK AND EX SANITARY MH RIM=5101.43 INV NW=5090.24 INV NE=5090.20 EX SANITARY MH RIM=5081.77 INV NE=5074.65 INV SW=5074.84 EX SANITARY MH RIM=5075.75 INV E=5067.17 INV SW=5072.65 INV SW=5067.52 EX SANITARY MH 3 RIM=5074.1 INV N=5059.3 INV S=5058.4 INV W=5058.6 CORE DRILL AND CONNECT TO EX SANITARY MANHOLE RIM=5070.80 INV S=5060.80 EX SANITARY MH RIM=5087.07 INV NW=5076.63 INV NE=5076.50 INV SW=5076.60 EX STORM DRAIN MH EXISTING INLET AND STORM DRAINS EX SANITARY MH RIM=5101.46 INV NE=5091.40 INV SW=5091.53 EX WATER MH RIM=5075.70 ALIGN-A ALIGN-B ALIGN-C ALIGN-F ALIGN-G ALIGN-D ALIGN-E ALIGN-H ALIGN-I ALIGN-K TRIANGLE DRIVE AVONDALE ROAD TRIANGLE DRIVE WOODROW DRIVE KIM DRIVE PEYTON DRIVE PEYTON DRIVE FOUNTAIN DRIVE AVONDALE ROAD ALIGN-L 30' UE, DE & EAE 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C1.0_General Notes.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 CONSTRUCTION NOTES A. STANDARD GRADING AND EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES THE EROSION CONTROL INSPECTOR MUST BE NOTIFIED AT LEAST TWENTY-FOUR (24) HOURS PRIOR TO ANY CONSTRUCTION ON THIS SITE. THERE SHALL BE NO EARTH DISTURBING ACTIVITY OUTSIDE THE LIMITS DESIGNATED ON THE ACCEPTED PLANS. ALL REQUIRED PERIMETER SILT AND CONSTRUCTION FENCING SHALL BE INSTALLED PRIOR TO ANY LAND DISTURBING ACTIVITIES (STOCKPILING, STRIPPING, GRADING, ETC.). ALL OTHER REQUIRED EROSION CONTROL MEASURES SHALL BE INSTALLED AT THE APPROPRIATE TIME IN THE CONSTRUCTION SEQUENCE AS INDICATED IN THE APPROVED PROJECT SCHEDULE, CONSTRUCTION PLANS, AND EROSION CONTROL REPORT. AT ALL TIMES DURING CONSTRUCTION, THE DEVELOPER SHALL BE RESPONSIBLE FOR PREVENTING AND CONTROLLING ON-SITE EROSION INCLUDING KEEPING THE PROPERTY SUFFICIENTLY WATERED SO AS TO MINIMIZE WIND BLOWN SEDIMENT. THE DEVELOPER SHALL ALSO BE RESPONSIBLE FOR INSTALLING AND MAINTAINING ALL EROSION CONTROL FACILITIES SHOWN THEM. PRE-DISTURBANCE VEGETATION SHALL BE PROTECTED AND RETAINED WHEREVER POSSIBLE. REMOVAL OR DISTURBANCE OF EXISTING VEGETATION SHALL BE LIMITED TO THE AREA(S) REQUIRED FOR IMMEDIATE CONSTRUCTION OPERATION, AND FOR THE SHORTEST PRACTICAL PERIOD OF TIME. ALL SOILS EXPOSED DURING LAND DISTURBING ACTIVITY (STRIPPING, GRADING, UTILITY INSTALLATIONS, STOCKPILING, FILLING, ETC.) SHALL BE KEPT IN A ROUGHENED CONDITION BY RIPPING OR DISKING ALONG LAND CONTOURS UNTIL MULCH, VEGETATION, OR OTHER PERMANENT EROSION CONTROL BMP'S ARE INSTALLED. NO SOILS IN AREAS OUTSIDE PROJECT STREET RIGHTS-OF-WAY SHALL REMAIN EXPOSED BY LAND DISTURBING ACTIVITIES FOR MORE THAN THIRTY (30) DAYS BEFORE REQUIRED TEMPORARY OR PERMANENT EROSION CONTROL (E.G. SEED/MULCH, LANDSCAPING, ETC.) IS INSTALLED, UNLESS OTHERWISE APPROVED BY THE CITY OF FORT COLLINS. IN ORDER TO MINIMIZE EROSION POTENTIAL, ALL TEMPORARY (STRUCTURAL) EROSION CONTROL MEASURES SHALL: A. BE INSPECTED AT A MINIMUM OF EVERY TWO (2) WEEKS AND AFTER EACH SIGNIFICANT STORM EVENT 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C1.0_General Notes.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL GENERAL NOTES AS ADOPTED FROM LARIMER COUNTY URBAN AREA STREET STANDARDS APPENDIX E 1. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF PUBLIC IMPROVEMENTS SHALL MEET OR EXCEED THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LARIMER COUNTY URBAN AREA STREET STANDARDS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE MOST RESTRICTIVE STANDARD SHALL APPLY. ALL WORK SHALL BE INSPECTED AND APPROVED BY THE CITY OF FORT COLLINS. 2. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE. 3. THESE PUBLIC IMPROVEMENT CONSTRUCTION PLANS SHALL BE VALID FOR A PERIOD OF THREE YEARS FROM THE DATE OF APPROVAL BY THE CITY OF FORT COLLINS ENGINEER. USE OF THESE PLANS AFTER THE EXPIRATION DATE WILL REQUIRE A NEW REVIEW AND APPROVAL PROCESS BY THE CITY OF FORT COLLINS PRIOR TO COMMENCEMENT OF ANY WORK SHOWN IN THESE PLANS. 4. THE ENGINEER WHO HAS PREPARED THESE PLANS, BY EXECUTION AND/OR SEAL HEREOF, DOES HEREBY AFFIRM RESPONSIBILITY TO THE CITY OF FORT COLLINS, AS BENEFICIARY OF SAID ENGINEER'S WORK, FOR ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS, AND APPROVAL OF THESE PLANS BY THE CITY OF FORT COLLINS ENGINEER SHALL NOT RELIEVE THE ENGINEER WHO HAS PREPARED THESE PLANS OF ALL SUCH RESPONSIBILITY. FURTHER, TO THE EXTENT PERMITTED BY LAW, THE ENGINEER HEREBY AGREES TO HOLD HARMLESS AND INDEMNIFY THE CITY OF FORT COLLINS, AND ITS OFFICERS AND EMPLOYEES, FROM AND AGAINST ALL LIABILITIES, CLAIMS, AND DEMANDS WHICH MAY ARISE FROM ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS. 5. ALL SANITARY SEWER AND WATER LINE CONSTRUCTION AND ALL POWER AND OTHER "DRY" UTILITY INSTALLATIONS, SHALL CONFORM TO THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE CITY OF FORT COLLINS ENGINEER. 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION NORTH 0 30' 60' 120' SCALE: 1"= 60'-0" 180' CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL LEGEND (1.) THE EROSION CONTROL INSPECTOR MUST BE NOTIFIED AT LEAST TWENTY-FOUR (24) HOURS PRIOR TO ANY CONSTRUCTION ON THIS SITE. (2.) THERE SHALL BE NO EARTH-DISTURBING ACTIVITY OUTSIDE THE LIMITS DESIGNATED ON THE ACCEPTED PLANS. (3.) ALL REQUIRED PERIMETER SILT AND CONSTRUCTION FENCING SHALL BE INSTALLED PRIOR TO ANY LAND DISTURBING ACTIVITY (STOCKPILING, STRIPPING, GRADING, ETC). ALL OTHER REQUIRED EROSION CONTROL MEASURES SHALL BE INSTALLED AT THE APPROPRIATE TIME IN THE CONSTRUCTION SEQUENCE AS INDICATED IN THE APPROVED PROJECT SCHEDULE, CONSTRUCTION PLANS, AND EROSION CONTROL REPORT. (4.) AT ALL TIMES DURING CONSTRUCTION, THE DEVELOPER SHALL BE RESPONSIBLE FOR PREVENTING AND CONTROLLING ON-SITE EROSION INCLUDING KEEPING THE PROPERTY SUFFICIENTLY WATERED SO AS TO MINIMIZE WIND BLOWN SEDIMENT. THE DEVELOPER SHALL ALSO BE RESPONSIBLE FOR INSTALLING AND MAINTAINING ALL EROSION CONTROL FACILITIES SHOWN HEREIN. (5.) PRE-DISTURBANCE VEGETATION SHALL BE PROTECTED AND RETAINED WHEREVER POSSIBLE. REMOVAL OR DISTURBANCE OF EXISTING VEGETATION SHALL BE LIMITED TO THE AREA(S) REQUIRED FOR IMMEDIATE CONSTRUCTION OPERATIONS, AND FOR THE SHORTEST PRACTICAL PERIOD OF TIME. (6.) ALL SOILS EXPOSED DURING LAND DISTURBING ACTIVITY (STRIPPING, GRADING, UTILITY INSTALLATIONS, STOCKPILING, FILLING, ETC.) SHALL BE KEPT IN A ROUGHENED CONDITION BY RIPPING OR DISKING ALONG LAND CONTOURS UNTIL MULCH, VEGETATION, OR OTHER PERMANENT EROSION CONTROL BMPS ARE INSTALLED. NO SOILS IN AREAS OUTSIDE PROJECT STREET RIGHTS-OF-WAY SHALL REMAIN EXPOSED BY LAND DISTURBING ACTIVITY FOR MORE THAN THIRTY (30) DAYS BEFORE REQUIRED TEMPORARY OR PERMANENT EROSION CONTROL (E.G. SEED/MULCH, LANDSCAPING, ETC.) IS INSTALLED, UNLESS OTHERWISE APPROVED BY THE CITY/COUNTY. (7.) IN ORDER TO MINIMIZE EROSION POTENTIAL, ALL TEMPORARY (STRUCTURAL) EROSION CONTROL MEASURES SHALL: (A.) BE INSPECTED AT A MINIMUM OF ONCE EVERY TWO (2) WEEKS AND AFTER EACH SIGNIFICANT STORM EVENT AND REPAIRED OR RECONSTRUCTED AS NECESSARY IN ORDER TO ENSURE THE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. (B.) REMAIN IN PLACE UNTIL SUCH TIME AS ALL THE SURROUNDING DISTURBED AREAS ARE SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. (C.) BE REMOVED AFTER THE SITE HAS BEEN SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. (8.) WHEN TEMPORARY EROSION CONTROL MEASURES ARE REMOVED, THE DEVELOPER SHALL BE RESPONSIBLE FOR THE CLEAN UP AND REMOVAL OF ALL SEDIMENT AND DEBRIS FROM ALL DRAINAGE INFRASTRUCTURE AND OTHER PUBLIC FACILITIES. (9.) THE CONTRACTOR SHALL IMMEDIATELY CLEAN UP ANY CONSTRUCTION MATERIALS INADVERTENTLY DEPOSITED ON EXISTING STREETS, SIDEWALKS, OR OTHER PUBLIC RIGHTS OF WAY, AND MAKE SURE STREETS AND WALKWAYS ARE CLEANED AT THE END OF EACH WORKING DAY. (10.) ALL RETAINED SEDIMENTS, PARTICULARLY THOSE ON PAVED ROADWAY SURFACES, SHALL BE REMOVED AND DISPOSED OF IN A MANNER AND LOCATION SO AS NOT TO CAUSE THEIR RELEASE INTO ANY WATERS OF THE UNITED STATES. (11.) NO SOIL STOCKPILE SHALL EXCEED TEN (10) FEET IN HEIGHT. ALL SOIL STOCKPILES SHALL BE PROTECTED FROM SEDIMENT TRANSPORT BY SURFACE ROUGHENING, WATERING, AND PERIMETER SILT FENCING. ANY SOIL STOCKPILE REMAINING AFTER THIRTY (30) DAYS SHALL BE SEEDED AND MULCHED. (12.) THE STORMWATER VOLUME CAPACITY OF DETENTION PONDS WILL BE RESTORED AND STORM SEWER LINES WILL BE CLEANED UPON COMPLETION OF THE PROJECT AND BEFORE TURNING THE MAINTENANCE OVER TO THE CITY/COUNTY OR HOMEOWNERS ASSOCIATION (HOA). (13.) CITY ORDINANCE AND COLORADO DISCHARGE PERMIT SYSTEM (CDPS) REQUIREMENTS MAKE IT UNLAWFUL TO DISCHARGE OR ALLOW THE DISCHARGE OF ANY POLLUTANT OR CONTAMINATED WATER FROM CONSTRUCTION SITES. POLLUTANTS INCLUDE, BUT ARE NOT LIMITED TO DISCARDED BUILDING 8-UNIT 8-UNIT 6-UNIT 6-UNIT TOT LOT SPORTS COURT (110' X 50') CLUB HOUSE POOL AVONDALE ROAD TRIANGLE DRIVE 2' CURB CUT RIP RAP TYPE VL AS SHOWN D50=6" 1 N1 0.353 0.36 N2 0.36 2 N3 0.41 3 N4 0.33 4 5 6 7b 8 9 N5 0.55 0.276 0.301 0.211 1.872 12 STORM A PIPE - (45) STORM A PIPE - (44) FLOW TO EX. POND 1 EXISTING DETENTION POND 7a 11b 52.11 LF 12" HDPE @ 5.95% YARD INLET LATERALS HDPE N-12 (TYP) YARD INLET LATERALS HDPE N-12 (TYP) STORM A PIPE - (63) CDOT TYPE D AREA INLET STMH A1 EXISTING INLET CORE 8-UNIT 6-UNIT 24-UNIT 16-UNIT 16-UNIT 24-UNIT 24-UNIT PEYTON DRIVE AVONDALE ROAD TRIANGLE DRIVE RIP RAP TYPE VL AS SHOWN D50=6" 31 10 13 S2 0.125 0.25 S4 0.121 0.31 S5 0.125 0.29 S6 0.154 0.61 S7 0.155 0.25 S8 0.575 0.55 S9 0.112 0.63 S10 0.119 0.56 S11 0.201 0.46 S12 0.436 0.50 S13 0.041 0.45 S14 1.866 0.49 S15 1.153 0.66 S18 0.990 0.28 S17 0.810 0.18 S16 0.204 0.68 S19 0.352 0.25 14 15 16b 17 19 20 21 22 23 24 25 26 27 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION 0 15' 30' 60' SCALE: 1"= 30'-0" 120' NORTH CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL GRADING NOTES 1. ALL EASEMENTS ARE PROPOSED AND WILL BE DEDICATED BY THE PLAT. EASEMENTS ARE LABELED ON THE UTILITY PLAN. 2. THE DRIVES WITHIN THE SITE WILL BE PRIVATELY OWNED AND MAINTAINED. THERE WILL BE NO PUBLIC MAINTENANCE OF THE DRIVES. 3. LIMITS OF STREET CUT SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS SHALL BE IN ACCORDANCE WITH THE CITY STREET REPAIR STANDARDS. 4. NO OFF SITE GRADING IS PROPOSED WITH THIS DEVELOPMENT. 5. SEE LANDSCAPE PLAN FOR REVEGETATION METHODS AND DETAILS. 6. ALL SPOT ELEVATIONS SHOWN ARE FLOWLINE UNLESS NOTED OTHERWISE. 7. ALL RETAINING WALLS FOUR (4) FEET OR HIGHER WILL REQUIRE A BUILDING PERMIT. THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. PERMEABLE PAVEMENT CONSTRUCTION NOTES (PAVERS) 1. EXCAVATION OF SUBGRADE SHALL NOT COMMENCE UNTIL AFTER THE PRE-CONSTRUCTION MEETING. 2. SUBGRADE SHALL BE EXCAVATED USING LOW GROUND PRESSURE (LGP) TRACK EQUIPMENT TO MINIMIZE OVER COMPACTION OF THE SUBGRADE - FOR PARTIAL AND FULL INFILTRATION SECTIONS ONLY. 3. GRADING AND COMPACTION EQUIPMENT USED IN THE AREA OF THE PERMEABLE PAVEMENT SHOULD BE APPROVED BY THE ENGINEER PRIOR TO USE. 4. LOOSE MATERIALS SHALL NOT BE STORED ON THE PERMEABLE PAVEMENT AREA. 5. THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION, PREVENT SEDIMENT, DEBRIS, AND DIRT FROM ANY SOURCE FROM ENTERING THE PERMEABLE PAVEMENT SYSTEM. 6. PLACEMENT OF THE WEARING COURSES SHALL BE PERFORMED AFTER FINE GRADING AND LANDSCAPING IN ADJACENT AREAS IS COMPLETE. IF THE WEARING COURSE BECOMES CLOGGED DUE TO CONSTRUCTION ACTIVITIES, CLEAN THE SURFACE WITH A VACUUM MACHINE TO RESTORE THE INFILTRATION RATE AFTER CONSTRUCTION IS COMPLETE. THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C3.0_Grading.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION NORTH 0 15' 30' 60' SCALE: 1"= 30'-0" 120' THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C3.0_Grading.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL PERMEABLE PAVEMENT CONSTRUCTION NOTES (PAVERS) 1. EXCAVATION OF SUBGRADE SHALL NOT COMMENCE UNTIL AFTER THE PRE-CONSTRUCTION MEETING. 2. SUBGRADE SHALL BE EXCAVATED USING LOW GROUND PRESSURE (LGP) TRACK EQUIPMENT TO MINIMIZE OVER COMPACTION OF THE SUBGRADE - FOR PARTIAL AND FULL INFILTRATION SECTIONS ONLY. 3. GRADING AND COMPACTION EQUIPMENT USED IN THE AREA OF THE PERMEABLE PAVEMENT SHOULD BE APPROVED BY THE ENGINEER PRIOR TO USE. 4. LOOSE MATERIALS SHALL NOT BE STORED ON THE PERMEABLE PAVEMENT AREA. 5. THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION, PREVENT SEDIMENT, DEBRIS, AND DIRT FROM ANY SOURCE FROM ENTERING THE FF=4999.50 FF=5094.00 FF=5086.50 FF=5081.50 FF=5095.50 FF=4992.50 EX SANITARY MH RIM=5101.43 INV NW=5090.24 INV NE=5090.20 EX SANITARY MH RIM=5081.77 INV NE=5074.65 INV SW=5074.84 EX SANITARY MH RIM=5075.75 INV E=5067.17 INV SW=5072.65 INV SW=5067.52 EX SANITARY MH RIM=5087.07 INV NW=5076.63 INV NE=5076.50 INV SW=5076.60 EXISTING INLET AND STORM DRAINS EX SANITARY MH RIM=5101.46 INV NE=5091.40 INV SW=5091.53 EX WATER MH RIM=5075.70 ALIGN-A ALIGN-B ALIGN-C ALIGN-K TRIANGLE DRIVE WOODROW DRIVE AVONDALE ROAD CUT INTO EXISTING WATER MAIN NEW 8" X 8" TEE W/ T.B. AND TWO (2) 8" GATE VALVES 90 DEG. BEND W/ TB AND 8" GV 8" X 4" TEE W/ TB 4" GV 11 1/4 DEG. BEND W/ TB HYDRANT ASSEMBLY 8" X 6" TEE W/ TB 6" GV & 8" GV HYDRANT ASSEMBLY 90 DEG. BEND W/ TB AND 8" GV 8" X 4" TEE W/ TB 4" GV 4" FIRE LINE (TYP) 1" WATER FF=4984.40 FF=4990.75 FF=5092.50 FF=4992.20 FF=4997.20 FF=4995.40 FF=5095.50 CORE DRILL AND CONNECT TO EX SANITARY MANHOLE RIM=5070.80 INV S=5060.80 ALIGN-F ALIGN-G ALIGN-D ALIGN-E ALIGN-H ALIGN-I PEYTON DRIVE ALIGN-L 4" SEWER SERVICE (TYP) 4" SEWER SERVICE (TYP) 1" WATER SERVICE (TYP) 4" FIRE LINE (TYP) 4" FIRE LINE (TYP) 8" X 8" TEE W/ TB TWO (2) 8" GV INSTALL TEMPORARY FIRE HYDRANT ASSEMBLY 4" FIRE LINE (TYP) 2" WATER SERVICE (TYP) 4" SEWER SERVICE (TYP) 4" SEWER SERVICE (TYP) 4" FIRE LINE (TYP) 1-1/2" WATER SERVICE (TYP) HYDRANT ASSEMBLY 90 DEG. BEND W/ TB AND 8" GV 11 1/4 DEG. BEND W/ TB 22 1/2 DEG. BEND W/ TB 90 DEG. BEND W/ TB 90 DEG. BEND W/ TB 8" X 8" TEE W/ TB TWO (2) 8" GV 8" X 8" TEE W/ TB TWO (2) 8" GV 4" FIRE LINE (TYP) 2" WATER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 0 20' 40' 80' SCALE: 1"= 40'-0" 120' NORTH THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C6.0 Horizontal Control.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 HORIZONTAL CONTROL PLAN 12 12 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C6.0 Horizontal Control.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 NOTE: ALL LINES/CURVES SHOWN ARE AT TOP OF BACK OF CURB (TYPICAL) LINE & CURVE TABLES 13 13 5.0' MIN 6.0' MAX ƒ%(1' WITH THRUST BLOCK STA: 2+65.33, OFF: 5.00'L =STA: 0+95.00 ALIGN 'B' 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 3+55.30, OFF: 5.00'L 8" X 1" WATER LINE TAP WITH THRUST BOCK STA: 3+58.05, OFF: 5.00'L ƒ%(1' WITH THRUST BLOCK STA: 4+66.02, OFF: 7.42'L 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 4+90.99, OFF: 5.69'L 8" X 1" WATER LINE TAP WITH THRUST BOCK STA: 4+93.64, OFF: 5.57'L ƒ%(1' WITH THRUST BLOCK STA: 5+58.37, OFF: 6.27'L =STA: 1+93.67 ALIGN 'K' HYDRANT ASSEMBLY 8" X 6" SWIVEL TEE WITH THRUST BLOCK AND 6" GV STA: 5+49.70, OFF: 5.76'L 4" SAN. SEWER SERVICE STA: 2+85.49, OFF: 5.00'R 4" SAN. SEWER SERVICE STA: 4+15.88, OFF: 5.00'R EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE 5.0' MIN 6.0' MAX ƒ%(1' WITH THRUST BLOCK STA: 2+65.33, OFF: 5.00'L =STA: 3+04.91 ALIGN 'B' 8" X 8" WATER LINE TEE WITH THRUST BOCK AND 2-8" GV STA: 1+14.52, OFF: 5.02'L =STA: 5+45.55 ALIGN 'AVONDALE' EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE STA: 2+51.39, OFF: 9.98'L END OF EXISTING WATERMAIN REMOVE AND SALVAGE EXISTING HYDRANT ASSEMBLY AND RELOCATE TO STA: 2+61.33, AS SHOWN. 5(029((;,67,1*ƒ%(1'$1' INSTALL 1/2 WATERMAIN TO ACHIEVE INCREASES IN DEPTH OF COVER OVER WATERMAIN EXTENSION. 5.0' MIN 6.0' MAX ƒ%(1' WITH THRUST BLOCK STA: 2+88.00, OFF: 2.00'L =STA: 2+32.19 ALIGN 'D' ƒ%(1' WITH THRUST BLOCK STA: 2+13.54, OFF: 2.00'L =STA: 2+77.09 ALIGN 'G' ROAD CENTERLINE DESIGN PROFILE 5.0' MIN 6.0' MAX ƒ%(1' WITH THRUST BLOCK STA: 2+77.09, OFF: 5.46'L =STA: 2+13.54 ALIGN 'F' 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 1+76.99, OFF: 5.22'L 8" X 1.5" WATER LINE TAP WITH THRUST BOCK STA: 1+74.99, OFF: 5.21'L ƒ%(1' WITH THRUST BLOCK STA: 1+24.39, OFF: 0.00'R =STA: 1+08.50 ALIGN 'J' HYDRANT ASSEMBLY 8" X 6" SWIVEL TEE WITH THRUST BLOCK AND 6" GV STA: 2+38.22, OFF: 5.37'L 4" SAN. SEWER SERVICE STA: 2+46.34, OFF: 5.39'L EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE STA: 4+06.43, OFF: 8.83'L 30" RCP STORM DRAIN CROSSING STA: 3+14.37, OFF: 5.00'R 4" SAN. SEWER SERVICE 5.0' MIN 6.0' MAX 8" X 8" WATER LINE TEE WITH THRUST BOCK AND 2-8" GV STA: 4+35.62, OFF:10.53'L =STA: 3+36.75 ALIGNMENT 'AVONDALE' HYDRANT ASSEMBLY 8" X 6" SWIVEL TEE WITH THRUST BLOCK AND 6" GV STA: 3+65.92, OFF: 6.48'L ƒ%(1' WITH THRUST BLOCK STA: 3+46.14, OFF: 4.58'L 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 2+88.17, OFF: 5.00'L ƒ%(1' WITH THRUST BLOCK 5.0' MIN 6.0' MAX ƒ%(1' WITH THRUST BLOCK STA: 1+08.50, OFF: 23.78'L =STA: 1+24.39 ALIGN 'G' ƒ%(1' WITH THRUST BLOCK STA: 1+46.13, OFF: 3.00'L ƒ%(1' WITH THRUST BLOCK STA: 3+03.16, OFF: 5.21'L ƒ%(1' WITH THRUST BLOCK STA: 4+80.96, OFF: 5.46'L =STA: 1+03.00 ALIGN 'I' EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE STA: 0+76.61, OFF: 5.00'L 12" RCP STORM DRAIN CROSSING 5.0' MIN 6.0' MAX CUT 8" X 8" TEE INTO EXISTING MAIN WITH THRUST BLOCK AND 2-8" GV STA: 0+46.91, OFF: 5.08'R ELEVATION NOT KNOWN 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 1+24.65, OFF: 5.04'R 8" X 1" WATER LINE TAP WITH THRUST BOCK STA: 1+26.65, OFF: 5.03'R ƒ%(1' WITH THRUST BLOCK STA: 1+93.67, OFF: 5.08'R =STA: 5+58.37 ALIGN 'A' 4" SAN. SEWER SERVICE STA: 1+09.95, OFF: 4.96'R EXISTING GROUND 5.0' MIN 6.0' MAX ƒ%(1' WITH THRUST BLOCK STA: 1+03.00, OFF: 4.88'R =STA: 4+80.96 ALIGN 'J' ƒ%(1' WITH THRUST BLOCK STA: 2+52.50, OFF: 5.00'R =STA: 1+70.00 ALIGN 'H' HYDRANT ASSEMBLY 8" X 6" SWIVEL TEE WITH THRUST BLOCK AND 6" GV STA: 1+25.12, OFF: 5.00'L 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 1+96.13, OFF: 5.00'R 8" X 1.5" WATER LINE TAP INV IN:5082.23 SMH S-5 STA:3+47.87 OFF:0.35R RIM:5093.55 INV IN:5088.00 INV OUT:5087.80 EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE STA: 4+68.57, OFF: 0.76'R STA: 3+37.77, OFF: 0.00'R WATER MAIN CROSSING WATER MAIN CROSSING STA: 5+02.35, OFF: 0.00'R 12" HDPE STORM DRAIN CROSSING STA: 6+40.35, OFF: 0.00'R 18" RCP STORM DRAIN CROSSING STA: 6+15.57, OFF: 0.00'R 2" WATER SERVICE CROSSING STA: 6+17.91, OFF: 0.00'R 4" FIRE LINE CROSSING 4" SEWER SERVICE TAP 4" SEWER SERVICE TAP 4" SEWER SERVICE TAP EXTEND TO PROVIDE 18" MIN. CLEARANCE OVER WATER PIPE APPROX. INV AT WATER = 5085.30 96.93' of 8" PVC @ 1.75% 205.90' of 8" PVC @ 1.83% SMH S-4 STA:4+44.60 OFF:2.46R RIM:5092.00 INV IN:5086.10 INV OUT:5085.90 SMH S-3 STA:6+50.36 OFF:0.00L RIM:5086.58 INV OUT:5082.03 INV IN:5085.67 INV IN:5076.85 EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE 4" SEWER SERVICE TAP 4" SEWER SERVICE TAP 4" SEWER SERVICE TAP 184.22' of 8" PVC @ 3.00% 101.72' of 8" PVC @ 3.00% SMH N-4 STA:2+81.49 OFF:5.00R RIM:5095.40 INV OUT:5085.47 SMH N-3 STA:4+66.02 OFF:2.59R RIM:5086.71 INV IN:5079.94 INV OUT:5079.74 SMH N-2 STA:2+02.96 OFF:-5.00L RIM:5081.83 INV OUT:5076.65 INV IN:5082.23 2.00% EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE EXISTING SMH STA:0+00.00 OFF:0.00 RIM:5074.10 INV IN:5059.30 EXISTING SMH STA:0+00.00 OFF:0.00 RIM:5074.10 INV IN:5059.30 EXISTING SMH STA:1+27.54 OFF:0.00 RIM:5070.80 INV IN:5060.90 INV OUT:5060.80 4" SEWER SERVICE TAP 4" SEWER SERVICE TAP EXTEND TO PROVIDE 18" MIN. CLEARANCE OVER STORM PIPE APPROX. INV AT STORM = 5076.64 134.10' of 8" PVC @ 1.23% SMH S-2 STA:3+87.39 OFF:0.00 RIM:5086.58 INV IN:5080.38 INV OUT:5080.28 134.10' of 8" PVC @ 1.23% 208.03' of 8" PVC @ 7.67% 51.82' of 8" PVC @ 6.41% SMH S-3 STA:6+50.36 OFF:0.00L RIM:5086.58 INV OUT:5082.03 SMH S-1 STA:1+79.36 OFF:0.02R RIM:5070.17 INV IN:5064.32 INV OUT:5064.22 0+00 1+00 2+00 3+00 4+00 5060 5070 5062 5064 5066 5068 5058 5072 ALIGNMENT 'L' 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' HORIZONTAL SCALE: 1"= 40'-0" 5+00 5078 5074 5076 5080 STORM A PIPE - (63) TYPE D AREA INLET 5' TYPE R INLET RIM EL. = 5076.60 INV. EL. = 5073.00 STMH A1 EXISTING INLET CORE SOUTH WALL OF INLET BOX TO ACCEPT PIPING FROM PROPOSED DEVELOPMENT STORM A PIPE - (45) TRIANGLE DRIVE ONSITE DRAINS PER 12.30 LF 18" DRAINAGE PLANS RCP @ 1.30% CORE DRILL STORM A PIPE - (63) STMH A1 STMH A2 W/ NEENAH R-2553 GRATE EXISTING INLET CORE SOUTH WALL OF INLET BOX TO ACCEPT PIPING FROM PROPOSED DEVELOPMENT STORM A PIPE - (44) ONSITE LANDSCAPING DRAINS PER DRAINAGE PLANS TRIANGLE DRIVE STORM A PIPE - (45) 0 15' 30' 60' 90' HORIZ SCALE: 1"= 30'-0" 1-800-922-1987 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL NORTH NORTH 0 1.5' 3' 6' 9' VERT SCALE: 1"= 3'-0" THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: TRACT A 227,699 sq. ft. 5.227 acres TRACT B 226,287 sq. ft. 5.195 acres 8-UNIT 6-UNIT AVONDALE ROAD 18+00 17+00 16+00 15+00 14+00 END OF EXISTING PAVEMENT AND CURB & GUTTER STA. 14+18.5 +/- WATER QUALITY INFILTRATION SWALE ONSITE LANDSCAPE DRAINS PER DRAINAGE PLAN STMH B1 20' TYPE R INLET 5' TYPE R INLET STMH B2 DOUBLE CURB INLET STMH B3 STORM C, PIPE (34) STORM B PIPE - (21) STORM B PIPE - (22) STORM B PIPE - (23) STORM B PIPE - (24) AVONDALE ROAD ONSITE LANDSCAPE DRAINS PER DRAINAGE PLAN NORTH 1-800-922-1987 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 0 15' 30' 60' 90' HORIZ SCALE: 1"= 30'-0" 0 1.5' 3' 6' 9' VERT SCALE: 1"= 3'-0" THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: EX. 30" ADS N-12 PIPE TO BE REMOVED 18+00 EX. STM MANHOLE AND APPROX. 44 LF OF EX. 30" D/S STORM DRAIN TO BE REMOVED AND REPLACED AT GRADE SHOWN. 36.5 LF 24" RCP @ 2.0% TYPE R INLET 5,0(/ “ INV. EL. (E) = 5074.80 INV. EL (W) = 5075.00 20' TYPE R INLET STMH C1 TYPE D M-604-11 AREA INLET RIM EL. = 5070.0 INV EL. (E) = 5067.09 STMH C2 TEE INV. EL. = 5072.96 STORM C PIPE - (60) STORM C PIPE - (59) 5' TYPE R INLET AVONDALE ROAD STORM C PIPE - (34) ONSITE LANDSCAPE DRAINS PER DRAINAGE PLAN 12" LF HDPE @ 3.53% ONSITE LANDSCAPE DRAINS PER DRAINAGE PLAN NORTH 1-800-922-1987 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 0 15' 30' 60' 90' HORIZ SCALE: 1"= 30'-0" 0 1.5' 3' 6' 9' VERT SCALE: 1"= 3'-0" THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C4.0_Storm Plan and Profiles.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: EXISTING CURB & GUTTER TO REMAIN EXISTING CURB & GUTTER TO BE REMOVED REPLACE WITH CROSSPAN END OF EXISTING PAVEMENT EAST PROPERTY BOUNDARY STA: 6+65.77 INTERSECTION ALIGN 'C' STA: 5+50.97 ELEV = 5089.97 END OF PAVEMENT STA: 6+61.12 ELEV = 5086.10 INTERSECTION ALIGN 'E' STA: 4+60.82 ELEV = 5091.64 CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 0+52.58 ELEV = 5100.87 EDGE OF CROSSPAN STA: 0+58.10 ELEV = 5101.00 EVCS: 6+61.12 -2.92% EXISTING PAVEMENT CENTERLINE PROFILE EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE PVI STA: 3+61.50 PVI ELEV: 5093.40 K: 171.57 LVC: 100.00 BVCS: 3+11.50 BVCE: 5094.58 EVCS: 4+11.50 EVCE: 5092.52 GRADE BREAK STA = 2+08.70 ELEV = 5096.99 PVI STA: 5+90.88 PVI ELEV: 5089.35 K: 49.22 LVC: 140.48 BVCS: 5+20.64 BVCE: 5090.59 EVCS: 6+61.12 -2.35% -1.77% -2.35% -1.77% CENTERLINE PROFILE OF FUTURE EXTENSION OF AVONDALE ROAD EVCE: 5086.10 PVI STA: 10+40.00 PVI ELEV: 5068.59 K: 64.81 -2.92% RIGHT FLOWLINE DESIGN PROFILE EXISTING GROUND PVI STA:3+55.85 PVI ELEV:5092.49 K:130.22 LVC:150.00 BVCS: 2+80.85 BVCE: 5094.53 EVCS: 4+30.85 EVCE: 5091.32 GRADE BREAK STA = 2+08.70 ELEV = 5096.49 GRADE BREAK STA = 6+84.26 ELEV = 5085.44 PVI STA:5+90.88 PVI ELEV:5088.81 K:68.56 LVC:140.00 BVCS: 5+20.88 BVCE: 5089.91 EVCS: 6+60.88 EVCE: 5086.29 -2.72% -1.57% -3.61% -2.92% EXISTING GROUND PVI STA:3+55.85 PVI ELEV:5092.49 K:130.22 LVC:150.00 BVCS: 2+80.85 BVCE: 5094.53 EVCS: 4+30.85 EVCE: 5091.32 GRADE BREAK STA = 2+08.70 ELEV = 5096.49 GRADE BREAK STA = 6+84.26 ELEV = 5085.45 PVI STA:5+90.88 PVI ELEV:5088.82 K:68.56 LVC:140.00 BVCS: 5+20.88 BVCE: 5089.91 EVCS: 6+60.88 EVCE: 5086.29 -2.72% -1.57% -3.61% STA: 6+38.57 STA: 5+31.89 DRIVEOVER CURB Station: 2+00 Elev=5097.25 EXISTING GROUND FL=5096.62 FL=5096.62 CURB, GUTTER & GRADE BREAK STA = 2+70.33 ELEV = 5095.998 GRADE BREAK STA = 5+55.99 ELEV = 5082.405 INTERSECTION ALIGN 'B' INTERSECTION ALIGN 'C' INTERSECTION AVONDALE RD STA: 1+00.00 ELEV = 5098.42 EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE PVI STA: 1+92.75 PVI ELEV: 5099.60 K: 15.27 LVC: 100.00 BVCS: 1+42.75 BVCE: 5098.65 EVCS: 2+42.75 EVCE: 5097.28 -1.52% 5.69% 1.91% -4.64% -4.76% -4.63% 1.46% 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' HORIZONTAL SCALE: 1"= 40'-0" 2+00 3+00 4+00 5+00 5084 5094 5086 5088 5090 5092 5078 5080 5082 ALIGNMENT 'A' 0+00 1+00 6+00 5096 5084 5094 5086 5088 5090 5092 5078 5080 5082 5096 INTERIOR DRIVE PLAN & PROFILE 24 24 MATCHLINE-AVONDALE MATCHLINE-ALIGN 'B' MATCHLINE-ALIGN 'C' MATCHLINE-AVONDALE GRADE BREAK STA = 4+09.39 ELEV = 5087.850 INTERSECTION ALIGN 'A' STA: 1+00.00 ELEV = 5096.00 INTERSECTION ALIGN 'C' CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 0+88.00 ELEV = 5095.65 -3.05% 2.06% -3.32% -3.04% EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE PVI STA: 2+07.97 PVI ELEV: 5093.97 K: 178.07 LVC: 50.00 BVCS: 1+82.96 BVCE: 5094.80 EVCS: 2+32.97 EVCE: 5093.21 PVI STA: 1+28.85 PVI ELEV: 5096.59 K: 9.30 LVC: 50.00 BVCS: 1+03.85 BVCE: 5096.08 EVCS: 1+53.85 EVCE: 5095.76 -2.07% 0.88% INTERSECTION ALIGN 'B' STA: 2+70.33 ELEV = 5087.85 INTERSECTION AVONDALE RD STA: 1+00.00 ELEV = 5089.97 INTERSECTION ALIGN 'A' STA: 6+37.23 ELEV = 5082.40 -3.85% -2.00% -0.90% 0.70% -1.93% -1.80% CENTERLINE OF 6' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 2+83.83 ELEV = 5087.49 CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 6+25.31 ELEV = 5082.28 GRADE BREAK STA = 2+93.00 ELEV = 5092.971 INTERSECTION ALIGN 'D' INTERSECTION ALIGN 'G' STA: 2+19.00 ELEV = 5094.25 -1.63% -0.61% -2.26% CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 3+05.16 ELEV = 5092.88 0.90% EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE PVI STA: 2+19.00 PVI ELEV: 5094.17 K: 153.10 LVC: 98.17 BVCS: 1+69.92 BVCE: 5095.29 EVCS: 2+68.08 EVCE: 5093.38 GRADE BREAK STA = 2+75.09 ELEV = 5094.251 3.28% 2.58% INTERSECTION ALIGN 'F' INTERSECTION ALIGN 'J' STA: 1+00.00 ELEV = 5092.44 1.03% CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 2+90.09 ELEV = 5094.57 EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE -2.29% -0.70% -1.74% INTERSECTION ALIGN 'I' STA: 1+65.00 ELEV = 5089.00 INTERSECTION ALIGN 'E' STA: 1+00.00 ELEV = 5089.61 0.70% 2.00% CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 0+84.76 ELEV = 5089.79 CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 1+44.42 ELEV = 5088.73 EXISTING GROUND TYPE III BARRICADE SEE DETAIL ON SHEET 36 INSTALL ENHANCED CROSSWALK EXISTING STRIPING, (TYP) EXISTING CHEVRON ARROW SIGNS 18.2' 12' 23.6' 26.2' C A A A B B B B F G D E G G AVONDALE ROAD H A H J J KEY MAP THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE SEWER DETAILS 28 28 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com Chapter 25 N.T.S. INFLOW CURB AND GUTTER N.T.S. 2' VALLEY PAN DETAIL OUTFALL CURB & GUTTER N.T.S. FL N.T.S. 2' CURBED CHANNEL PRIVATE DRIVE/PARKING DETAILS LIMITS OF C & G 17 IN. (1.42 FT.) 3 FT. 9 IN. (3.75 FT.) 4 IN. 1.5 IN. 14 IN. (1.17 FT.) 6 IN. 1-3/8 IN. (.11 FT.) 3-3/8 IN. (.28 FT.) 18 IN. (1.5 FT.) 18 IN. (1.5 FT.) FLOW LINE 6 IN. 16 IN. R (1.33 FT.) 16 IN. R (1.33 FT.) WHERE WALK ADJOINS A CURB, IT SHALL BE CONSTRUCTED 1/4 INCH ABOVE THE CURB SLOPE SIDEWALK TO CURB - 1/4 IN. TO 1/2 IN. PER FT. 4 FT. MIN. 4 IN. 2 FT. 6 IN. 6 IN. 2 IN. 2 IN. R 1.5 IN. R 12 IN. 6 IN. 1.5 IN. 4-1/2 IN. 6 IN. 1/4 IN. 2.67 FT. 4.43 FT. 0.58 FT. 1.18 FT. 0.30 FT. 6 IN. 4 IN. 0.11 FT. 0.09 FT. 1/8 IN. R STREET DETAILS 30 30 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C8.0_Storm Sewer Details.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL STORM DRAIN DETAILS 31 31 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C8.0_Storm Sewer Details.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL STORM DRAIN DETAILS 32 32 NOTE: VALVE BOX SHALL BE CENTERED AND PLUMB OVER THE OPERATING NUT. WATER DETAILS 33 33 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com CP TEST STATION W J E I U S A A S U I E J W STATION LOCATOR LID PLAN VIEW LID SECTION VIEW VALVE BOX SECTION VIEW PVC WATER MAIN TRACER WIRE DETAIL CP TEST AND LOCATOR STATION BOX WATER DETAILS 34 34 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C7.0_Erosion Control Details.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL EROSION CONTROL DETAILS 35 35 SIGNING & STRIPING DETAILS 36 36 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com 8-UNIT 8-UNIT 6-UNIT 6-UNIT TOT LOT SPORTS COURT CLUB HOUSE POOL TRIANGLE DRIVE AVONDALE ROAD 1 2 2 SEE POCKET DETAIL 4/LID.3 TREES WITHIN CONTINUOUS CONNECTING POCKET, SEE LANDSCAPE PLAN FOR TREE LOCATIONS SLOTTED CURB SEE DETAIL 7/LID.3 NORTH 'B' BIOSWALE , SEE TABLE SHEET LID.3 NORTH 'A' BIOSWALE , SEE TABLE SHEET LID.3 NORTH 0 15' 30' 60' 90' SCALE: 1"= 30'-0" MATCHLINE (SEE SHEET LID.2) LID EXHIBIT - NORTH LID.1 37 THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgwood Hills - FP LID.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. Timm Development BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 8-UNIT 6-UNIT 24-UNIT 16-UNIT 16-UNIT 24-UNIT 24-UNIT PEYTON DRIVE AVONDALE ROAD TRIANGLE DRIVE GARAGE 3 5 6 POCKET SOIL SEE DETAIL 4/LID.3 'SILVA CELL' SEE DETAIL 3/LID.5 4" PVC PIPE CHECK DAMS SEE DETAIL SEE DETAIL 1 & 2 / LID.3 'SILVA CELL' SEE DETAIL 1/LID.5 'SILVA CELL' SEE DETAIL 2/LID.5 2 4 4 4 4 3 3 3 5 SOUTH 'A' BIOSWALE , SEE TABLE SHEET LID.3 SOUTH 'B' BIOSWALE , SEE TABLE SHEET LID.3 (900 SQ FT) BOULDER, (TYP) SLOTTED CURB, (TYP) SEE DETAIL 7/LID.3 SEE POCKET DETAIL 4/LID.3 TREES WITHIN CONTINUOUS CONNECTING POCKET, SEE LANDSCAPE PLAN FOR TREE LOCATIONS AVONDALE ROAD Ridgwood Hills - FP LID.dwg Tuesday, March 12, 2013 11:21:29 AM NORTH 0 15' 30' 60' 90' SCALE: 1"= 30'-0" LEGEND: MATCHLINE (SEE SHEET LID.1) LID EXHIBIT SLOTTED CURB 3" WIDE OPENING AT BOTTOM SEDIMENT TRAP, 3" DEPTH PERFORATED STEEL EDGER BIOSWALE WITH NATIVE WETLAND SEED MIX SLOPED TO DRAIN INLET, SEE LANDSCAPE PLAN NATIVE SEED, SEE LANDSCAPE PLAN SEE BIOSWALE DETAIL 4:1 MAX. HEIGHT LENGTH WIDTH UNDISTURBED SOIL PARKING/BUILDING PRECAST OVERFLOW STRUCTURE 12" PONDING DEPTH MIN. 30-MIL HDPE IMPERVIOUS MEMBRANE MIN. 12" THICK LAYER OF BIORETENTION SAND MEDIA (SEE BIORETENTION SAND MEDIA SPECIFICATION FROM CITY OF FORT COLLINS) MIN. 6" THICK LAYER OF PEA GRAVEL DIAPHRAGM (DEPTH VARIES, SEE PLAN) LAYER OF CDOT NO. 4 AGGREGATE MIN. 4" PERFORATED PVC PIPE 6" PERFORATED PVC SUBDRAIN PIPE SEE BIOSWALE DETAIL FOR BEDDING/STORAGE REQUIREMENTS STORM DRAIN MANHOLE WITH SLOTTED LID 4" PERFORATED PVC PIPE COLLECTION PIPE-1% SLOPE CHECK DAM WITH NOTCH 4-6" COBBLE (ENERGY DISSIPATORS) BELOW CHECK DAM UNDISTURBED NATIVE SOIL WITH VEGETATIVE COVER 3:1 SLOPE MAX 3:1 SLOPE MAX CHECK DAM WITH NOTCH LOW FLOW NOTCH 4" DRAIN PIPE Geogrid. 'J' 6"(150mm) minimum below backfill at base. Overlap 12"(300mm) minimum at top of Cells. Screw Cell decks to frames after snapping in place (typ.) 4"(100mm) aggregate base course Geotextile, 18"(450mm) minimum overlap past excavation Curb stop, per project specifications Tree KEY PLAN (for reference only) 1"(25mm) air space between Silva Cell deck and planting soil DeepRoot UB18-2 Root barrier Tree trunk, size varies SEE PLANTING NOTES 1"-3"(25mm-50mm) mulch above tree pit SEE PLANTING NOTES 8" stand pipe, connect to distribution Inspection riser pipe, cap shall reach 2" above aggregate mulch surface Anchor each Silva Cell to ground with (4) 10" (250mm) spike,<10mm dia., see Cell base for spike hole 4" PERFORATED CAPPED PIPE 5" PERFORATED PVC COLLECTION PIPE Tree root package, SEE PLANTING NOTES Planting soil, tamped to max. 85% compaction below root package and stand pipe DeepRoot UB18-2 Root barrier Tree root package, size varies SEE PLANTING NOTES Planting soil, tamped to max. 85% compaction below root package Curb and street per project specifications 5" PERFORATED PVC COLLECTION PIPE 1"-3"(25mm-50mm) SEE PLANTING NOTES 4" Aggregate Base Course Geotextile, 18"(450mm) minimum overlap past excavation 4"(100mm) aggregate sub base, compacted to 95% Silva Cell base slope to max. 5% Subgrade below geotextile and aggregate base course, compacted to 95% Planting soil per Silva Cell specifications, installed in 8"(200mm) lifts (2 lifts per cell) Geotextile on compacted subgrade Tree root package, size varies Planting soil, tamped to max. 85% compaction below root package Setback from face of curb* Deciduous shrubs planted per planting note specifications Tree Fold ends of ArborTie back, secure to stake with 1" galvanized roofing nail or use an knot. ArborTie ArborTie NOTE: Specified ArborTie green (or white) staking and guying material is to be flat, woven, polypropylene material, 3 4" wide with 900 lb. break strength. ArborTie shall be fastened to stakes in a manner which permits tree movement and supports the tree. Detail shall be used in conjunction with Silva Cell standard details. SILVA CELLS PER WATER CAPTURE DETALS SEE SHEET LID.4 5" PERFORATED PCV PIPE SEE SHEET LID.4 SLOTTED CURB (TYP) SEE DETAIL 7/LID.3 5" PERFORATED PCV PIPE SEE SHEET LID.4 SILVA CELLS UNDER PARKING SEE SHEET LID.4 SLOTTED CURB (TYP) SEE DETAIL 7/LID.3 5" PERFORATED PCV PIPE SEE SHEET LID.4 SILVA CELLS UNDER PARKING ISLAND SEE SHEET LID.4 SLOTTED CURB (TYP) SEE DETAIL 7/LID.3 LID EXHIBIT - ENLARGEMENTS LID.5 41 THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgwood Hills - FP LID.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. Timm Development BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE DR FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 07-31-2014 FP Resubmittal 41 3 SILVA CELL LAYOUT-ISLAND 3 1 SILVA CELL LAYOUT-ISLAND 1 2 SILVA CELL LAYOUT-ISLAND 2 ArborTie Silva Cell Standard Pavement Profile Per Project Specifications 1, 2, or 3-Layer Silva Cell System Per Project Specifications Silva Cell Standard Pavement Profile Per Project Specifications 1, 2, or 3-Layer Silva Cell System Per Project Specifications Inspection Riser Cast Iron Cap, f lush with surface, for use in paved areas Inspection Riser PVC Cap, for use in planting areas INSPECTION RISER Inspection Riser: Rigid at pavement section, perforated at Silva Cell system. Where perforated, wrap in geotextile and secure with zip ties. Inspection Riser for Soil: Rigid from Silva Cell deck to top of finished pavement surface. Align with opening in Cell deck. ArborTie Tree KEY PLAN (for reference only) Tree 4"(100mm) aggregate sub base, compacted to 95% Silva Cell base slope to max. 5% Subgrade below geotextile and aggregate base course, compacted to 95% Planting soil per Silva Cell specifications, installed in 8"(200mm) lifts (2 lifts per cell) Geotextile on compacted subgrade Paving base course per project specifications Tree root package, SEE PLANTING NOTES Planting soil, tamped to max. 85% compaction below root package Geogrid. 'J' 6"(150mm) minimum below backfill at base. Overlap 12"(300mm) minimum at top of Cells. Backfill, installed in 8"(200mm) lifts, within 4"-6"(100-150mm) from top of decks, compacted to 95% 3/16" x14"(5mm x 350mm) zip ties, attaching Geogrid to Silva Cells at each level and at Cell deck Anchor each Silva Cell to ground with (4) 10" (250mm) spike,<10mm dia., see Cell base for spike hole Screw Cell decks to frames after snapping in place (typ.) DeepRoot UB18-2 Root barrier Tree trunk, size varies SEE PLANTING NOTES 1"-3" mulch above tree pit SEE PLANTING NOTES 4" Perforated capped PVC pipe 4" aggregate base course Geotextile, 18"(450mm) minimum overlap past excavation 1"(25mm) air space between Silva Cell deck and planting soil 1-3" wood mulch. SEE PLANTING NOTES 8"(200mm) stand pipe, connected to distribution pipe, cap shall reach (50mm) above aggregate mulch surface 5" Perforated PVC collection pipe. SEE PLANTING NOTES LID EXHIBIT DETAILS LID.4 40 THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgwood Hills - FP LID.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. Timm Development BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE DR FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 07-31-2014 FP Resubmittal 41 ARBOR TIE-1 INSPECTION RISER SILVA CELL-PARKING LOT ISLAND DETAIL ARBOR TIE-2 SILVA CELL-PARKING LOT ISLAND DETAIL (TWO TREES) (SINGLE TREE) FOOTING 4-6" COBBLE (ENERGY DISSIPATORS) BELOW CHECK DAM FOR FIRST 18" SIDE SLOPE 3:1 MAX. 1' FILTER FABRIC SEE PLANTING NOTES FILTER FABRIC SEE PLANTING NOTES PLANTING MIX. SEE PLANTING NOTES COMPACTED SUBGRADE/BACKFILL CURB CURB. SEE SITE NOTES DRIVE. SEE SITE NOTES LANDSCAPE BOULDERS STORM WATER RETENTION LIP 3:1 TYP LID EXHIBIT DETAILS LID.3 39 THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgwood Hills - FP LID.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. Timm Development BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE DR FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 07-31-2014 FP Resubmittal 41 WATER QUALITY BIOSWALE SWALE BIOSWALE DETAIL NORTH BIOSWALE OVERFLOW DETAIL GRASS SWALE CHECK DAM CHECK DAM - SECTION POCKET DETAIL 1 2 4 5 3 7 BIOSWALE SIZING TABLE BIOSWALE WIDTH HEIGHT LENGTH C.A. NORTH A 7' 4' 110' #1 NORTH B 6' 4' 135' #2 SOUTH A 8' 4' 89' #4 SOUTH B SEE PLAN 30" * SEE PLAN #3 *NON-TRAPAZOIDAL - SOUTH LID.2 38 THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgwood Hills - FP LID.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. Timm Development BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE DR FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 07-31-2014 FP Resubmittal 41 IMPERVIOUS CAPTURE BIOSWALE PRE-TREATMENT CONTINOUS TREE POCKET W/ PLANTING SOIL (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE DR FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 07-31-2014 FP Resubmittal 41 INDEX TO DRAWINGS LEGEND: IMPERVIOUS CAPTURE LID DATA TABLE: AREA UNIT PERCENTAGE TOTAL IMPERVIOUS: 264,087 SF BUILDING 81,986 SF SIDEWALKS 43,826 SF SPORT COURT 5,500 SF POOL DECK 4,789 SF DRIVES & PARKING 127,986 SF TOTAL DRIVES & PARKING: 127,986 SF TOTAL DRIVES, PARKING & BUILDING: 209,972 SF 100% TOTAL PRETREATMENT CAPTURE: 173,616 SF 83% SOUTH CAPTURE 117,071 SF 56% NORTH CAPTURE 56,545 SF 27% CAPTURE BASIN AREA 1: 27,456 CAPTURE BASIN AREA 2: 29,089 CAPTURE BASIN AREA 3: 53,282 CAPTURE BASIN AREA 4: 26,811 CAPTURE BASIN AREA 5: 23,039 CAPTURE BASIN AREA 6: 13,939 BIOSWALE PRE-TREATMENT CONTINOUS TREE POCKET W/ PLANTING SOIL CAPTURE BASIN AREAS: TOTAL: 173,616 EDGED SURFACE 1/8 IN. 3/4 IN MIN. COMBINATION CURB, GUTTER AND SIDEWALK "HOLLYWOOD" (OBSOLETE FOR REPLACEMENT ONLY) DUMMY JOINT FOR WALKS VERTICAL 6 IN. CURB, GUTTER AND SIDEWALK DRIVE-OVER CURB, GUTTER AND SIDEWALK N.T.S. PRIVATE DRIVE SIDEWALK CHASE 5/8" GALV. STEEL PLATE 3/8" BRASS SCREW 18" O.C. WITH COUNTERSUNK HEAD FLUSH WITH PLATE SIDEWALK (TYP.) 2.0' OPENING EDGE OF STREET BACK OF CURB FLOW LINE 3" TYP. SLOPE SIDEWALK (TYP.) 6"X6" - 10/10 W.W.F. 12" 6" 6" 2.0' 6" 3.0' 12" 6" 4.5" 6" 1" 12" 1.5" 1.5"R 1.5"R 6" 12" 12" 1" 6"X6" - 10/10 W.W.F. 6" 1" 1'-6" 6" 1.5"R 2"R 6" 6" 12" STREET DETAILS 29 29 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com SIGN LEGEND: R1-2 YIELD SIGN 36"X36"X36" WITH STREET NAME SIGNS ABOVE W-11-2 "PED XING" SIGN 30"X30" AND W16-7P "ARROW" SIGN 24"X18" (AS DIRECTED BY THE LOCAL ENTITY ENGINEER) "NO PARKING ANYTIME" SIGN 1. SEE SHEET 36 FOR STANDARD SIGN DETAILS NOTES: STRIPING LEGEND: SOLID DOUBLE YELLOW 4" WIDE SOLID WHITE LINE 6" WIDE SOLID WHITE LINE 8" WIDE DO NOT ADD THE WHITE DASHED LINE THAT DELINEATES THE OUTER EDGE OF THE ROUNDABOUT AS IT EXISTS ON THE OTHER 3 LEGS "NO PARKING ANYTIME" SIGN ONE WITH ARROW POINTING EAST AND ONE WITH ARROW POINTING WEST H D C B A G F E NORTH 0 HORIZONTAL SCALE: 15' 30' 60' 90' 1"=30' CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL SIGNING & STRIPING PLAN 27 27 J "EMERGENCY ACCESS ONLY" SIGN ROAD CENTERLINE DESIGN PROFILE PVI STA: 2+43.53 PVI ELEV: 5089.55 K: 20.30 LVC: 54.19 BVCS: 2+16.44 BVCE: 5089.36 EVCS: 2+70.62 EVCE: 5089.01 GRADE BREAK STA = 2+48.85 ELEV = 5088.998 5.50% 2.84% 1.80% INTERSECTION ALIGN 'J' STA: 1+00.00 ELEV = 5083.67 INTERSECTION ALIGN 'H' 3.58% CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 2+62.36 ELEV = 5089.21 EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE -0.02% GRADE BREAK STA = 4+76.08 ELEV = 5083.670 GRADE BREAK STA = 1+98.81 ELEV = 5091.758 -3.37% -4.26% INTERSECTION ALIGN 'E' STA: 4+11.08 ELEV = 5085.42 INTERSECTION ALIGN 'I' INTERSECTION ALIGN 'G' STA: 1+01.11 ELEV = 5092.44 INTERSECTION ALIGN 'D' -0.69% -2.24% -3.15% -1.18% -2.61% CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 0+87.36 ELEV = 5092.82 CENTERLINE OF 3' WIDE DRAIN PAN GRADE IN = 8.33% TYPICAL STA: 2+23.38 ELEV = 5091.11 EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE PVI STA: 4+11.08 PVI ELEV: 5085.37 K: 137.90 LVC: 75.00 BVCS: 3+73.58 BVCE: 5086.55 EVCS: 4+48.58 EVCE: 5084.39 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' HORIZONTAL SCALE: 1"= 40'-0" 5092 5094 5096 5098 ALIGNMENT 'F' 1+00 2+00 5092 5094 5096 5098 5090 ALIGNMENT 'G' 1+00 2+00 3+00 5100 5102 3+00 5086 5084 5090 5088 5092 1+00 2+00 3+00 ALIGNMENT 'H' 5092 5094 5096 5098 5100 5102 5092 5094 5096 5098 5090 5086 5084 5090 5088 5092 1+00 2+00 3+00 5088 5080 5082 5084 5086 ALIGNMENT 'I' 5088 5080 5082 5084 5086 1+00 2+00 3+00 4+00 5094 5086 5088 5090 5092 ALIGNMENT 'J' 5084 5+00 5096 5086 5084 5082 6+00 INTERIOR DRIVE PLAN & PROFILE 26 26 MATCHLINE-ALIGN 'G' MATCHLINE-ALIGN 'D' MATCHLINE-ALIGN 'D' MATCHLINE-ALIGN 'J' MATCHLINE-ALIGN 'F' MATCHLINE-ALIGN 'F' MATCHLINE-ALIGN 'E' MATCHLINE-ALIGN 'E' MATCHLINE-ALIGN 'I' MATCHLINE-ALIGN 'H' MATCHLINE-ALIGN 'H' MATCHLINE-ALIGN 'J' MATCHLINE-ALIGN 'J' MATCHLINE-ALIGN 'G' MATCHLINE-ALIGN 'D' MATCHLINE-ALIGN 'E' MATCHLINE-ALIGN 'I' 5080 5078 5076 KEY MAP KEY MAP PROPOSED 3' CROSSPAN PROPOSED HANDICAP ACCESS RAMP (TYP) PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED HANDICAP ACCESS RAMP (TYP) PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 3' CROSSPAN PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 3' CROSSPAN PROPOSED 6" VERTICAL CURB & GUTTER CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE PROPOSED 2' SIDEWALK CHASE AND CURBCUT SEE DETAILS SHEET 29 PROPOSED 2' SIDEWALK CHASE AND CURBCUT SEE DETAILS SHEET 29 ALIGNMENT 'F' ALIGNMENT 'G' ALIGNMENT 'H' ALIGNMENT 'I' ALIGNMENT 'J' THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE PVI STA: 5+12.30 PVI ELEV: 5081.52 K: 21.97 LVC: 100.00 BVCS: 4+62.30 BVCE: 5083.44 EVCS: 5+62.30 EVCE: 5081.87 PVI STA: 1+84.15 PVI ELEV: 5089.41 K: 48.49 LVC: 50.00 BVCS: 1+59.15 BVCE: 5089.63 EVCS: 2+09.15 EVCE: 5088.93 PVI STA: 4+16.41 PVI ELEV: 5085.21 K: 24.46 LVC: 50.00 BVCS: 3+91.41 BVCE: 5085.66 EVCS: 4+41.41 EVCE: 5084.25 GRADE BREAK STA = 2+30.19 ELEV = 5092.971 GRADE BREAK STA = 3+84.25 ELEV = 5094.000 INTERSECTION AVONDALE DR STA: 4+22.07 ELEV = 5093.57 INTERSECTION ALIGN 'J' STA: 1+00.00 ELEV = 5091.76 INTERSECTION ALIGN 'F' EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE PVI STA: 1+57.04 PVI ELEV: 5092.62 K: 98.38 LVC: 100.00 BVCS: 1+07.04 BVCE: 5091.86 EVCS: 2+07.04 EVCE: 5092.86 1.50% 0.49% 0.67% -6.62% 1.66% 2.00% -1.62% GRADE BREAK STA = 2+36.37 ELEV = 5089.610 GRADE BREAK STA = 3+64.28 ELEV = 5091.79 GRADE BREAK STA = 1+00.00 ELEV = 5085.419 INTERSECTION AVONDALE DR STA: 4+02.40 ELEV = 5091.64 INTERSECTION ALIGN 'H' INTERSECTION ALIGN 'J' 2.00% -2.00% -5.46% 1.70% 3.53% EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE PVI STA: 1+95.40 PVI ELEV: 5088.79 K: 32.71 LVC: 50.00 BVCS: 1+70.40 BVCE: 5087.91 EVCS: 2+20.41 EVCE: 5089.29 3.53% 1+00 2+00 3+00 4+00 5094 5086 5088 5090 5092 ALIGNMENT 'B' 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' HORIZONTAL SCALE: 1"= 40'-0" 5084 5098 5096 5094 5086 5088 5090 5092 5084 5098 5096 1+00 2+00 5080 5082 ALIGNMENT 'C' 5088 5084 5086 5092 5080 5082 5088 5090 5084 5086 5092 3+00 4+00 5+00 1+00 2+00 3+00 5088 5084 5086 2+00 3+00 4+00 5+00 5094 5086 5088 5090 5092 ALIGNMENT 'D' ALIGNMENT 'E' 5096 5098 1+00 5094 5086 5088 5090 5092 5096 5098 5094 5090 5092 5088 5084 5086 5094 5090 5092 4+00 INTERIOR DRIVE PLAN & PROFILE 25 25 MATCHLINE-ALIGN 'C' MATCHLINE-ALIGN 'A' MATCHLINE-ALIGN 'A' MATCHLINE-ALIGN 'C' MATCHLINE-AVONDALE MATCHLINE-AVONDALE MATCHLINE-ALIGN 'B' MATCHLINE-ALIGN 'A' MATCHLINE-ALIGN 'A' 6+00 MATCHLINE-ALIGN 'J' MATCHLINE-ALIGN 'J' MATCHLINE-AVONDALE MATCHLINE-AVONDALE MATCHLINE-ALIGN 'F' MATCHLINE-AVONDALE MATCHLINE-ALIGN 'J' MATCHLINE-AVONDALE MATCHLINE-ALIGN 'J' MATCHLINE-ALIGN 'H' KEY MAP KEY MAP PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED HANDICAP ACCESS RAMP (TYP) PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 6' CROSSPAN PROPOSED 6' CROSSPAN PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED HANDICAP ACCESS RAMP (TYP) PROPOSED 5' CONCRETE WALK PROPOSED HANDICAP ACCESS RAMP (TYP) PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 5' CONCRETE WALK PROPOSED HANDICAP ACCESS RAMP (TYP) CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 5+00 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE ALIGNMENT 'C' ALIGNMENT 'B' ALIGNMENT 'E' ALIGNMENT 'D' 5090 THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com 5098 5074 5076 KEY MAP SECTION B-B TYPICAL INTERIOR DRIVE AISLE SECTION W/ GARAGE N.T.S. B B PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 3' CROSSPAN PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 5' PROPOSED CONCRETE WALK HANDICAP ACCESS RAMP (TYP) CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com DETACHED SIDEWALK (TYP) SEE DETAILS SHEET 29 Station: 2+50 Elev=5096.02 EXISTING GROUND FL=5095.39 FL=5095.39 CURB, GUTTER & DETACHED SIDEWALK SEE DETAILS SHEET 29 Station: 3+00 Elev=5094.85 EXISTING GROUND FL=5094.22 FL=5094.22 CURB, GUTTER & DETACHED SIDEWALK SEE DETAILS SHEET 29 Station: 3+50 Elev=5093.72 EXISTING GROUND FL=5093.09 FL=5093.09 CURB, GUTTER & DETACHED SIDEWALK SEE DETAILS SHEET 29 Station: 4+00 Elev=5092.75 EXISTING GROUND FL=5092.12 FL=5092.12 CURB, GUTTER & DETACHED SIDEWALK SEE DETAILS SHEET 29 EXISTING GROUND Station: 4+50 Elev=5091.83 FL=5091.20 FL=5091.20 Station: 5+00 Elev=5090.95 EXISTING GROUND FL=5090.32 FL=5090.32 CURB, GUTTER & DETACHED SIDEWALK SEE DETAILS SHEET 29 Station 5+50 Elev=5089.98 EXISTING GROUND FL=5089.35 FL=5089.40 DRIVEWAY APPROACH SEE DETAIL SHEET 29 Station 6+00 Elev=5088.52 EXISTING GROUND FL=5087.89 FL=5087.94 DRIVE-OVER CURB SEE DETAIL SHEET 29 Station 6+50 Elev=5086.60 EXISTING GROUND FL=5085.97 FL=5085.97 CURB & GUTTER SEE DETAILS SHEET 29 3+00 4+00 5+00 6+00 5090 5092 5094 5088 AVONDALE ROAD - LEFT FLOWLINE 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' HORIZONTAL SCALE: 1"= 40'-0" 2+00 5098 5100 5096 0+00 1+00 AVONDALE ROAD PLAN & PROFILE 23 23 MATCHLINE-ALIGN 'D' MATCHLINE-ALIGN 'E' MATCHLINE-ALIGN 'C' MATCHLINE-ALIGN 'A' 7+00 5086 KEY MAP 5090 5092 5094 5088 5098 5100 5096 5086 3+00 4+00 5+00 6+00 5090 5092 5094 5088 2+00 5098 5100 5096 0+00 1+00 7+00 5086 5090 5092 5094 5088 5098 5100 5096 5086 PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER AVONDALE ROAD - RIGHT FLOWLINE CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 5098 5096 -1+00 -0+50 0+00 0+50 1+00 5098 5096 -1+00 -0+50 0+00 0+50 1+00 5094 5100 5096 -1+00 -0+50 0+00 0+50 1+00 5094 5096 -1+00 -0+50 0+00 0+50 1+00 5094 5092 -1+00 -0+50 0+00 0+50 1+00 5094 5092 -1+00 -0+50 0+00 0+50 1+00 5092 5090 -1+00 -0+50 0+00 0+50 1+00 5092 5090 -1+00 -0+50 0+00 0+50 1+00 5090 5088 -1+00 -0+50 0+00 0+50 1+00 5090 5088 5086 -1+00 -0+50 0+00 0+50 1+00 5088 5086 5084 THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com INSTALL DRIVE-OVER CURB LVC: 200.00 BVCS: 9+40.00 BVCE: 5073.21 EVCS: 11+40.00 EVCE: 5067.05 -4.62% -1.54% GRADE BREAK STA = 11+83.98 ELEV = 5066.379 EXISTING GROUND 3+00 4+00 5+00 6+00 5090 5092 5094 5088 AVONDALE DRIVE 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' HORIZONTAL SCALE: 1"= 40'-0" 2+00 5098 5100 5102 5096 5104 0+00 1+00 AVONDALE ROAD PLAN & PROFILE 22 22 MATCHLINE-ALIGN 'D' MATCHLINE-ALIGN 'E' MATCHLINE-ALIGN 'C' MATCHLINE-ALIGN 'A' 7+00 8+00 9+00 10+00 11+00 5070 5072 5074 5066 5068 5078 5080 5082 5076 5084 5064 5086 5082 5084 5086 5090 5092 5088 KEY MAP SECTION A-A AVONDALE ROAD TYPICAL STREET SECTION N.T.S. A A REMOVE EXISTING CURB & GUTTER BETWEEN PROPOSED CURB RETURNS & REPLACE WITH CROSSPAN INSTALL ASPHALT CURB FOR TEMPORARY TURN AROUND REMOVE EXISTING CURB & GUTTER & INSTALL NEW CURB &GUTTER FOR CURB RETURN, AS SHOWN (BOTH SIDES OF INTERSECTION) PROPOSED 5' CONCRETE WALK INSTALL DRIVE-OVER CURB PROPOSED 5' CONCRETE WALK PROPOSED 6" VERTICAL CURB & GUTTER PROPOSED 6" VERTICAL CURB & GUTTER END OF PROPOSED ASPHALT END OF EXISTING PAVEMENT BEGIN PROPOSED ASPHALT PROPOSED CENTERLINE OF FUTURE AVONDALE ROAD EXTENSION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL SIDEWALK CHASE & CURB CUT PER DETAIL D-10B ON SHEET 29 THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 STORM PLAN & PROFILE 21 21 PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C4.0_Storm Plan and Profiles.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 STORM PLAN & PROFILE 20 20 OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C4.0_Storm Plan and Profiles.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 STORM PLAN & PROFILE 19 19 5084 5082 5086 5060 5070 5062 5064 5066 5068 5058 5072 5078 5074 5076 5080 5084 5082 5086 SEWER PLAN & PROFILE 18 18 MATCHLINE-AVONDALE KEY MAP SAN MH S-3 SAN MH S-1 SAN MH S-2 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 30' UE,DE & EAE THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com 127.96' OF 8" PVC @ 0.50% SMH S-5 STA:3+47.87 OFF:0.35R RIM:5093.55 INV IN:5088.00 INV OUT:5087.80 EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE STA: 2+90.50, OFF: 5.00'R 2" WATER SERVICE CROSSING STA: 2+88.17, OFF: 5.00'R 4" FIRE LINE CROSSING STA: 4+06.00, OFF: 1.21'R 30" RCP STORM DRAIN CROSSING 4" SEWER SERVICE TAP 4" SEWER SERVICE TAP 75.92' of 8" PVC @ 0.50% SMH S-6 STA:3+46.58 OFF:5.51R RIM:5093.60 INV IN:5088.48 INV OUT:5088.38 SMH S-7 STA:2+19.15 OFF:5.00R RIM:5092.83 INV OUT:5089.22 INV IN:5076.85 INV OUT:5075.63 EXISTING GROUND STA: 0+77.21, OFF: 5.00'R 12" RCP STORM DRAIN CROSSING 4" SEWER SERVICE TAP EXTEND TO PROVIDE 18" MIN. CLEARANCE OVER WATER PIPE APPROX. INV AT WATER = 5078.98 4" SEWER SERVICE TAP 165.41' of 8" PVC @ 0.50% SMH N-1 STA:0+37.56 OFF:-4.92L RIM:5084.30 INV IN:5075.83 SMH N-2 STA:2+02.96 OFF:-5.00L RIM:5081.83 INV OUT:5076.65 3+00 4+00 5+00 6+00 7+00 5090 5092 5094 5082 5084 5086 5088 AVONDALE ROAD 2+00 3+00 4+00 5094 5086 5088 5090 5092 3+00 4+00 5+00 5084 5094 5086 5088 5090 5092 5076 5078 5080 5082 ALIGNMENT 'A' ALIGNMENT 'D' 0+00 1+00 2+00 5084 5086 5076 5078 5080 5082 5074 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' ALIGNMENT 'K' HORIZONTAL SCALE: 1"= 40'-0" 5084 NORTH 5074 SEWER PLAN & PROFILE 17 17 MATCHLINE-ALIGN 'K' MATCHLINE-ALIGN 'D' MATCHLINE-ALIGN 'L' MATCHLINE-AVONDALE MATCHLINE-ALIGN 'A' KEY MAP KEY MAP SAN MH N-1 SAN MH N-2 SAN MH N-2 SAN MH N-3 SAN MH N-4 SAN MH S-3 SAN MH S-4 SAN MH S-5 SAN MH S-5 SMH S-7 SAN MH S-6 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL SAN MH S-6 6+00 30' UE,DE & EAE 30' UE,DE & EAE 5078 5080 ALIGNMENT 'A' AVONDALE ROAD ALIGNMENT 'K' ALIGNMENT 'D' THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com WITH THRUST BOCK STA: 1+98.13, OFF: 5.03'R ƒ%(1' WITH THRUST BLOCK STA: 1+28.23, OFF: 5.71'R EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE 5.0' MIN 6.0' MAX ƒ%(1' WITH THRUST BLOCK STA: 1+70.00, OFF: 3.65'L =STA: 2+52.50 ALIGN 'I' ƒ%(1' WITH THRUST BLOCK STA: 1+08.00, OFF: 3.65'L =STA: 2+40.01 ALIGN 'E' EXISTING GROUND 1+00 2+00 3+00 4+00 5094 5086 5088 5090 5092 1+00 2+00 3+00 5088 5080 5082 5084 5086 ALIGNMENT 'J' 0+00 1+00 2+00 5084 5076 5078 5080 5082 5074 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' HORIZONTAL SCALE: 1"= 40'-0" ALIGNMENT 'K' 5084 1+00 2+00 5086 5088 5090 ALIGNMENT 'H' 5084 ALIGNMENT 'I' 5082 5080 5078 5076 5+00 5082 5080 WATER PLAN & PROFILE 16 16 MATCHLINE-ALIGN 'I' MATCHLINE-ALIGN 'E' MATCHLINE-ALIGN 'J' MATCHLINE-ALIGN 'H' MATCHLINE-ALIGN 'G' MATCHLINE-ALIGN 'I' MATCHLINE-ALIGN 'A' KEY MAP KEY MAP ƒ%(1':7% ƒ%(1':7% ƒ%(1':7% FIRE HYDRANT ASSEMBLY 8" X 6" TEE W/ TB AND 6" GV ƒ%(1':7% AND 8" GV ƒ%(1':7% ƒ%(1':7% AND 8" GV ƒ%(1':7% ƒ%(1':7% ƒ%(1':7% ƒ%(1':7% AND 8" GV 1" WATER SERVICE (TYP) 4" FIRELINE (TYP) CUT INTO EXISTING WATER MAIN NEW 8" X 8" TEE W/ TB AND TWO (2) 8" GV CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 1-1/2" WATER SERVICE (TYP) 4" FIRELINE (TYP) 5078 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE ALIGNMENT 'H' ALIGNMENT 'I' ALIGNMENT 'J' ALIGNMENT 'K' THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com STA: 2+32.19, OFF: 5.00'L =STA: 1+88.00 ALIGN 'F' 8" X 2" WATER LINE TAP WITH THRUST BOCK STA: 2+90.50, OFF: 5.00'L EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE STA: 3+89.99, OFF: 7.82'R 30" RCP STORM DRAIN CROSSING STA: 4+01.69, OFF: 7.76'R SAN. SEWER MAIN CROSSING 5.0' MIN 6.0' MAX ƒ%(1' WITH THRUST BLOCK STA: 2+40.01, OFF: 8.00'L =STA: 1+08.00 ALIGN 'H' 8" X 8" WATER LINE TEE WITH THRUST BOCK AND 2-8" GV STA: 4+16.21, OFF: 7.70'R =STA: 4+68.69 ALIGN 'AVONDALE' DIP WATER LINE FOR SEWER CROSSING SEE DETAIL, SHEET 33 EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE 5092 5094 5096 2+00 3+00 5080 5082 5084 5086 ALIGNMENT 'F' 1+00 2+00 5094 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' ALIGNMENT 'G' HORIZONTAL SCALE: 1"= 40'-0" 5090 2+00 3+00 4+00 5086 5088 5090 ALIGNMENT 'D' 5084 ALIGNMENT 'E' 5086 5088 5086 5088 3+00 4+00 2+00 3+00 WATER PLAN & PROFILE 15 15 MATCHLINE-ALIGN 'F' MATCHLINE-AVONDALE MATCHLINE-AVONDALE MATCHLINE-AVONDALE MATCHLINE-ALIGN 'H' MATCHLINE-AVONDALE MATCHLINE-ALIGN 'G' MATCHLINE-ALIGN 'D' MATCHLINE-ALIGN 'J' MATCHLINE-ALIGN 'F' KEY MAP KEY MAP ƒ%(1':7% 8" X 8" TEE W/ TB AND TWO (2) 8" GV FIRE HYDRANT ASSEMBLY ƒ%(1':7% 2" WATER SERVICE (TYP) 4" FIRELINE (TYP) ƒ%(1':7% 8" X 8" TEE W/ TB AND TWO (2) 8" GV ƒ%(1':7% AND 8" GV ƒ%(1':7% AND 8" GV 1-1/2" WATER SERVICE (TYP) 4" FIRELINE (TYP) FIRE HYDRANT ASSEMBLY ƒ%(1':7% AND 8" GV ƒ%(1':7% AND 8" GV 8" X 6" TEE W/ TB AND 6" GV 8" X 6" TEE W/ TB AND 6" GV CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL DIP WATERLINE FOR SEWER CROSSING SEE DETAIL, SHEET 33 5092 5090 5088 5092 5+00 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE ALIGNMENT 'D' ALIGNMENT 'E' ALIGNMENT 'F' ALIGNMENT 'G' THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com 5.0' MIN 6.0' MAX RELOCATE HYDRANT ASSEMBLY 8" X 6" SWIVEL TEE WITH THRUST BLOCK AND 6" GV STA: 2+61.33, OFF: 9.86'L ƒ%(1' WITH THRUST BLOCK STA: 2+91.91, OFF: 8.47'L 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 2+95.83, OFF: 9.04'L 8" X 2" WATER LINE TAP WITH THRUST BOCK STA: 2+98.18, OFF: 9.37'L 8" X 1" WATER LINE TAP WITH THRUST BOCK STA: 3+09.50, OFF: 10.82'L 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 3+11.53, OFF: 11.06'L 8" X 8" WATER LINE TEE WITH THRUST BOCK AND 2-8" GV STA: 3+36.75, OFF: 13.45'L =STA: 4+35.62 ALIGN 'D' ƒ%(1' WITH THRUST BLOCK STA: 4+44.68, OFF: 12.11'L 8" X 8" WATER LINE TEE WITH THRUST BOCK AND 2-8" GV STA: 4+68.69, OFF: 13.76'L =STA: 0+86.19 ALIGN 'E' 8" X 1" WATER LINE TAP WITH THRUST BOCK STA: 4+62.47, OFF: 13.42'L 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 4+64.51, OFF: 13.54'L 8" X 8" WATER LINE TEE WITH THRUST BOCK AND 2-8" GV STA: 5+45.55, OFF: 14.52'L =STA: 1+14.52 ALIGN 'C' 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 6+16.44, OFF: 14.51'L 8" X 2" WATER LINE TAP WITH THRUST BOCK STA: 6+18.77, OFF: 14.51'L TEMP HYDRANT ASSEMBLY STA: 6+52.66, OFF: 14.50'L 18" RCP STORM DRAIN STA: 6+40.35, OFF: 14.50'L 12" HDPE STORM DRAIN STA: 4+97.20, OFF: 14.50'L 12" HDPE STORM DRAIN STA: 2+54.13, OFF: 9.93'L 4" SAN. SEWER SERVICE STA: 5+32.92, OFF: 14.50'L 4" SAN. SEWER SERVICE STA: 3+81.27, OFF: 16.16'L EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE 5.0' MIN 6.0' MAX ƒ%(1' WITH THRUST BLOCK STA: 0+95.00, OFF: 5.00'R =STA 2+65.33 ALIGN 'A' 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 1+02.00, OFF: 5.00'R 8" X 1" WATER LINE TAP WITH THRUST BOCK STA: 1+00.00, OFF: 5.00'R HYDRANT ASSEMBLY 8" X 6" SWIVEL TEE WITH THRUST BLOCK AND 6" GV STA: 1+23.22, OFF: 5.00'R ƒ%(1' WITH THRUST BLOCK STA: 4+04.91, OFF: 5.00'R =STA: 2+65.33 ALIGN 'C' 8" X 4" FIRE LINE TEE WITH THRUST BOCK STA: 2+96.84, OFF: 5.00'R 8" X 3/4" WATER LINE TAP WITH THRUST BOCK STA: 2+99.14, OFF: 5.00'R HYDRANT ASSEMBLY 8" X 6" SWIVEL TEE WITH THRUST BLOCK AND 6" GV STA: 3+72.68, OFF: 5.00'R 8" X 1.5" IRRIGATION LINE TAP WITH THRUST BOCK STA: 2+56.74, OFF: 5.00'R 4" STORM DRAIN CROSSING STA: 3+69.63, OFF: 5.00'R EXISTING GROUND ROAD CENTERLINE DESIGN PROFILE 3+00 4+00 5+00 6+00 7+00 5090 5094 5082 5084 5086 5088 AVONDALE ROAD 1+00 2+00 3+00 4+00 5094 5086 5088 5090 5092 3+00 4+00 5+00 5084 5086 5088 5090 5092 5076 5078 5080 5082 ALIGNMENT 'A' ALIGNMENT 'B' 1+00 2+00 5080 5082 0 20' 40' 80' VERTICAL SCALE: 1"= 4'-0" 120' ALIGNMENT 'C' HORIZONTAL SCALE: 1"= 40'-0" 5084 2+00 5088 5084 5086 WATER PLAN & PROFILE 14 14 MATCHLINE-ALIGN 'B' MATCHLINE-ALIGN 'C' MATCHLINE-ALIGN 'E' MATCHLINE-ALIGN 'D' MATCHLINE-ALIGN 'K' MATCHLINE-ALIGN 'C' MATCHLINE-ALIGN 'A' MATCHLINE-AVONDALE MATCHLINE-AVONDALE MATCHLINE-ALIGN 'B' MATCHLINE-ALIGN 'C' KEY MAP KEY MAP FIRE HYDRANT ASSEMBLY FIRE HYDRANT ASSEMBLY ƒ%(1':7% 8" X 6" TEE W/ TB AND 6" GV 8" X 6" TEE W/ TB AND 6" GV & 8" GV 3/4" WATER SERVICE (TYP) 4" FIRELINE (TYP) WATERLINE JOINT '()/(&7,212)ƒ MAXIMUM PER JOINT 4" FIRELINE (TYP) 1" WATER SERVICE (TYP) ƒ%(1':7% AND 8" GV ƒ%(1':7% 8" X 8" TEE W/ TB AND TWO (2) 8" GV ƒ%(1':7% AND 8" GV 1" WATER SERVICE (TYP) 4" FIRELINE (TYP) 1" WATER SERVICE (TYP) 4" FIRELINE (TYP) 1" WATER SERVICE (TYP) 4" FIRELINE (TYP) ƒ%(1' W/ TB ƒ%(1':7% AND 8" GV TEMP. FIRE HYDRANT ASSEMBLY 2" WATER SERVICE (TYP) 4" FIRELINE (TYP) 8" X 8" TEE W/ TB AND TWO (2) 8" GV 8" X 8" TEE W/ TB AND TWO (2) 8" GV 1" WATER SERVICE (TYP) 4" FIRELINE (TYP) 1" WATER SERVICE (TYP) 4" FIRELINE (TYP) ƒ%(1' W/ TB ƒ%(1' W/ TB 2" WATER SERVICE (TYP) 4" FIRELINE (TYP) 8" X 8" TEE W/ TB AND TWO (2) 8" GV RELOCATE EXISTING. HYDRANT AS SHOWN REPLACE EX. BEND W/ 8" X 6" TEE W/ TB & 6" GV FIRE HYDRANT ASSEMBLY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL 5080 5082 3+00 6+00 5092 30' UE,DE & EAE 30' UE,DE & EAE 30' UE,DE & EAE ALIGNMENT 'A' AVONDALE ROAD ALIGNMENT 'B' ALIGNMENT 'C' THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com SERVICE (TYP) 4" FIRE LINE (TYP) 2" WATER SERVICE (TYP) 8" X 6" TEE W/ TB 6" GV HYDRANT ASSEMBLY 4" SEWER SERVICE (TYP) 11 1/4 DEG. BEND W/ TB 90 DEG. BEND W/ TB 90 DEG. BEND W/ TB AND 8" GV 1-1/2" WATER SERVICE (TYP) 4" FIRE LINE (TYP) 4" SEWER SERVICE (TYP) 90 DEG. BEND W/ TB HYDRANT ASSEMBLY 8" X 6" TEE W/ TB 6" GV 22 1/2 DEG. BEND W/ TB 11 1/4 DEG. BEND W/ TB 4" SEWER SERVICE (TYP) 96.93 LF 8" PVC SEWERLINE SMH S-4 SMH S-6 SMH S-3 39.93 LF 8" PVC WATERLINE STORM DRAIN CATCH BASIN 150.81 LF 8" PVC WATERLINE 149.85 LF 8" PVC WATERLINE 87.11 LF 8" PVC WATERLINE 96.93 LF 8" PVC SEWERLINE 76.14 LF 8" PVC WATERLINE 134.10 LF 8" PVC SEWERLINE 208.03 LF 8" PVC SEWERLINE 51.82 LF 8" PVC SEWERLINE SMH S-1 SMH S-2 SMH S-7 127.96 LF 8" PVC SEWERLINE 75.92 LF 8" PVC SEWERLINE 39.93 LF 8" PVC WATERLINE SMH S-5 41 LF 30" RCP STORM DRAIN 128 LF 30" RCP STORM DRAIN 107 LF 12" HDPE STORM DRAIN 60 LF 12" HDPE STORM DRAIN 60 LF 12" HDPE STORM DRAIN 122 LF 30" RCP STORM DRAIN 52 LF 18" HDPE STORM DRAIN 127 LF 30" RCP STORM DRAIN 320 LF 30" RCP STORM DRAIN 8 LF 12" HDPE STORM DRAIN 103 LF 12" HDPE STORM DRAIN 60 LF 30" RCP STORM DRAIN 35 LF 24" HDPE STORM DRAIN 20 LF 12" HDPE STORM DRAIN 25 LF 12" HDPE STORM DRAIN 54 LF 12" HDPE STORM DRAIN DIP WATERLINE FOR SEWER CROSSING 1" WATER SERVICE (TYP) 64 LF 12" HDPE STORM DRAIN 28 LF 12" HDPE STORM DRAIN STORM DRAIN CATCH BASIN RELOCATE EX. HYDRANT AS SHOWN REPLACE EX. BEND W/ 8" X 6" TEE W/ TB & 6" GV 34 LF 12" HDPE STORM DRAIN 8" X 6" TEE W/ TB 6" GV 62 LF 12" HDPE STORM DRAIN 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com UTILITY PLAN-SOUTH 11 0 15' 30' 60' 90' 11 SCALE: 1"= 30'-0" NORTH MATCHLINE - SEE SHEET 10 AVONDALE ROAD KEY MAP N.T.S. UTILITY NOTES 1. ALL SANITARY SEWER PIPE IS 8" PVC SDR-35, UNLESS NOTED OTHERWISE.. 2. ALL SANITARY SEWER, WATER AND STORMWATER CONSTRUCTION SHALL CONFORM TO FORT COLLINS SANITATION DISTRICT WASTEWATER AND STORMWATER DEVELOPMENT CONSTRUCTION STANDARDS AND DETAILS. 3. ALL REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III OR BETTER UNLESS NOTED OTHERWISE. 4. ALL WATERLINE TO BE CONSTRUCTED A MINIMUM OF 5' AND A MAXIMUM OF 6' (5' TYPICAL) BELOW FINISHED GRADE UNLESS OTHERWISE NOTED. 5. ALL WATERLINE SERVICES TO BE 2" UNLESS NOTED OTHERWISE. 6. PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN WATER AND SEWER MAINS. 7. SEE GRADING PLANS FOR EASEMENT DELINEATION, DIMENSIONS AND DETAILS. 8. REFER TO GRADING, DRAINAGE AND EROSION CONTROL PLANS FOR FLOODPLAIN INFORMATION. 9. SEE UTILITY DETAIL SHEETS FOR SERVICE CONNECTION DETAILS. 10. REDUCED PRESSURE PRINCIPLE (RP) BACK-FLOW-PREVENTION-DEVICES TO BE INSTALLED ON THE FIRE LINE RISERS AND DOMESTIC WATER SERVICES. 11. TELEPHONE AND CATV TO BE INSTALLED IN COMMON TRENCH WITH POWER. CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL LEGEND PROPOSED STORM DRAIN WITH MANHOLE PROPOSED STORM INLET PROPOSED SANITARY SEWER WITH MANHOLE PROPOSED WATERLINE WITH VALVE & FIRE HYDRANT PROPOSED WATERLINE TAP METER PROPOSED FIRELINE TAP PROPOSED IRRIGATION LINE WITH METER PROPOSED ELECTRIC LINE PROPOSED GAS LINE EXISTING SANITARY SEWER EXISTING WATERLINE EXISTING STORM DRAIN PIPE SERVICE (TYP) 8" X 4" TEE W/ TB 4" GV 4" FIRE LINE (TYP) 1" WATER SERVICE (TYP) 4" FIRE LINE (TYP) 1" WATER SERVICE (TYP) 4" SEWER SERVICE (TYP) 4" SEWER SERVICE (TYP) 4" SEWER SERVICE (TYP) 4" SEWER SERVICE (TYP) 8" X 4" TEE W/ TB 4" GV 4" SEWER SERVICE (TYP) 3/4" WATER SERVICE (TYP) 8" X 4" TEE W/ TB 4" GV 8" X 6" TEE W/ TB 6" GV HYDRANT ASSEMBLY 8" X 6" TEE W/ TB 6" GV 90 DEG. BEND W/ TB 146.76 LF 8" PVC WATERLINE 165.41 LF 8" PVC SEWERLINE 101.72 LF 8" PVC SEWERLINE 93.32 LF 8" PVC WATERLINE SMH N-3 SMH N-2 201.27 LF 8" PVC WATERLINE 184.22 LF 8" PVC SEWERLINE SMH N-4 312.25 LF 8" PVC WATERLINE SMH N-1 4" FIRE LINE (TYP) 139 LF 24" HDPE STORM DRAIN 85 LF 12" HDPE STORM DRAIN 39 LF 12" HDPE STORM DRAIN 22 LF 12" HDPE STORM DRAIN STORM DRAIN MH 69 LF 12" HDPE STORM DRAIN 79 LF 12" HDPE STORM DRAIN 44 LF 12" HDPE STORM DRAIN 20 LF 12" HDPE STORM DRAIN 71 LF 12" HDPE STORM DRAIN 24 LF 12" HDPE STORM DRAIN 17 LF 12" HDPE STORM DRAIN 78 LF 12" HDPE STORM DRAIN 52 LF 12" HDPE STORM DRAIN 37 LF 12" HDPE STORM DRAIN 20 LF 12" HDPE STORM DRAIN 47 LF 12" HDPE STORM DRAIN 22 LF 12" HDPE STORM DRAIN 77 LF 12" HDPE STORM DRAIN 19 LF 12" HDPE STORM DRAIN STORM DRAIN CATCH BASIN 64 LF 12" HDPE STORM DRAIN 125 LF 12" HDPE STORM DRAIN 24 LF 12" HDPE STORM DRAIN 48 LF 12" HDPE STORM DRAIN 24 LF 12" HDPE STORM DRAIN 1.5" WATER IRRIGATION SERVICE W/ METER 41 LF 12" HDPE STORM DRAIN IRRIGATION CONTROLLER SAWCUT AND REPLACE EXISTING PAVEMENT IN THIS AREA 16 LF 24" HDPE STORM DRAIN STORM DRAIN MH 4" FIRE LINE (TYP) 1" WATER SERVICE (TYP) 24 LF 12" HDPE STORM DRAIN 30' UE, DE & EAE 30' UE, DE & EAE 30' UE 34.6' 31.4' 30' UE, DE & EAE 2+00 THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com UTILITY PLAN-NORTH 10 0 15' 30' 60' 90' 10 SCALE: 1"= 30'-0" NORTH CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL NORTH KEY MAP N.T.S. MATCHLINE - SEE SHEET 11 UTILITY NOTES 1. ALL SANITARY SEWER PIPE IS 8" PVC SDR-35, UNLESS NOTED OTHERWISE.. 2. ALL SANITARY SEWER, WATER AND STORMWATER CONSTRUCTION SHALL CONFORM TO FORT COLLINS SANITATION DISTRICT WASTEWATER AND STORMWATER DEVELOPMENT CONSTRUCTION STANDARDS AND DETAILS. 3. ALL REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III OR BETTER UNLESS NOTED OTHERWISE. 4. ALL WATERLINE TO BE CONSTRUCTED A MINIMUM OF 5' AND A MAXIMUM OF 6' (5' TYPICAL) BELOW FINISHED GRADE UNLESS OTHERWISE NOTED. 5. ALL WATERLINE SERVICES TO BE 2" UNLESS NOTED OTHERWISE. 6. PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN WATER AND SEWER MAINS. 7. SEE GRADING PLANS FOR EASEMENT DELINEATION, DIMENSIONS AND DETAILS. 8. REFER TO GRADING, DRAINAGE AND EROSION CONTROL PLANS FOR FLOODPLAIN INFORMATION. 9. SEE UTILITY DETAIL SHEETS FOR SERVICE CONNECTION DETAILS. 10. REDUCED PRESSURE PRINCIPLE (RP) BACK-FLOW-PREVENTION-DEVICES TO BE INSTALLED ON THE FIRE LINE RISERS AND DOMESTIC WATER SERVICES. 11. TELEPHONE AND CATV TO BE INSTALLED IN COMMON TRENCH WITH POWER. LEGEND PROPOSED STORM DRAIN WITH MANHOLE PROPOSED STORM INLET PROPOSED SANITARY SEWER WITH MANHOLE PROPOSED WATERLINE WITH VALVE & FIRE HYDRANT PROPOSED WATERLINE TAP METER PROPOSED FIRELINE TAP PROPOSED IRRIGATION LINE WITH METER PROPOSED ELECTRIC LINE PROPOSED GAS LINE EXISTING SANITARY SEWER EXISTING WATERLINE EXISTING STORM DRAIN PIPE PERMEABLE PAVEMENT SYSTEM. 6. PLACEMENT OF THE WEARING COURSES SHALL BE PERFORMED AFTER FINE GRADING AND LANDSCAPING IN ADJACENT AREAS IS COMPLETE. IF THE WEARING COURSE BECOMES CLOGGED DUE TO CONSTRUCTION ACTIVITIES, CLEAN THE SURFACE WITH A VACUUM MACHINE TO RESTORE THE INFILTRATION RATE AFTER CONSTRUCTION IS COMPLETE. GRADING NOTES 1. ALL EASEMENTS ARE PROPOSED AND WILL BE DEDICATED BY THE PLAT. EASEMENTS ARE LABELED ON THE UTILITY PLAN. 2. THE DRIVES WITHIN THE SITE WILL BE PRIVATELY OWNED AND MAINTAINED. THERE WILL BE NO PUBLIC MAINTENANCE OF THE DRIVES. 3. LIMITS OF STREET CUT SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS SHALL BE IN ACCORDANCE WITH THE CITY STREET REPAIR STANDARDS. 4. NO OFF SITE GRADING IS PROPOSED WITH THIS DEVELOPMENT. 5. SEE LANDSCAPE PLAN FOR REVEGETATION METHODS AND DETAILS. 6. ALL SPOT ELEVATIONS SHOWN ARE FLOWLINE UNLESS NOTED OTHERWISE. 7. ALL RETAINING WALLS FOUR (4) FEET OR HIGHER WILL REQUIRE A BUILDING PERMIT. GRADING PLAN SOUTH 8 8 DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 GRADING PLAN NORTH 7 7 28 29 32 33 30 STORM B PIPE - (24) STORM B PIPE - (23) STORM B PIPE - (22) 34 16a EX. STM MANHOLE AND APPROX. 44 LF OF EX. 30" D/S STORM DRAIN TO BE REMOVED AND REPLACED AT GRADE SHOWN. 36.5 LF 24" RCP @ 2.00% 64.10 LF 12" HDPE @ 6.99% YARD INLET LATERALS HDPE N-12 (TYP) 5' TYPE R INLET RIM EL. = 5087.6 INV IN = 5077.68 INV OUT = 5075.93 STMH B1 20' TYPE R INLET 5' TYPE R INLET 6' DENVER #16 STMH B2 COMBO INLET STMH C1 TYPE D M-604-11 AREA INLET RIM EL. = 5070.0 STMH B3 STORM C PIPE - (34) CORE DRILL 12" HDPE STORM B PIPE - (21) STORM C PIPE - (59) 24" ADS AREA DRAIN RIM: 5091.50 INV: 5089.50 24" ADS AREA DRAIN RIM: 5090.44 INV: 5087.87 24" ADS AREA DRAIN RIM: 5094.25 INV: 5088.18 66.15 LF 12" HDPE @ 4.07% 24" ADS AREA DRAIN RIM: 5091.00 INV: 5085.05 24" ADS AREA DRAIN RIM: 5091.20 INV: 5085.09 24" ADS AREA DRAIN RIM: 5090.74 INV: 5087.57 24" ADS AREA DRAIN RIM: 5083.40 INV: 5078.42 24" ADS AREA DRAIN RIM: 5083.40 INV: 5078.83 24" ADS AREA DRAIN RIM: 5083.40 INV: 5079.05 53.65 LF 12" HDPE @ 1.0% 54.47 LF 12" HDPE @ 1.0% 7.00 LF 6" PVC @ 1.00% 7.00 LF 6" PVC @ 1.00% 2' SIDEWALK CHASE AND CURB CUT 7.00 LF 6" PVC @ 1.00% 7.00 LF 6" PVC @ 1.00% 35.54 LF 12" HDPE @ 5.97% STORM C PIPE - (60) CORE DRILL 12" HDPE 61.24 LF 12" HDPE @ 5.97% 72.51 LF 12" HDPE @ 5.97% 50.00 LF 12" HDPE @ 4.07% 6.65 LF 12" RCP @ 7.50% 16.4 LF 12" HDPE @ 2.01% 24" ADS AREA DRAIN RIM: 5083.32 INV: 5075.00 12.38 LF 6" PVC @ 1.00% 20.00 LF 8" HDPE @ 4.20% EXIST. FIRE HYDRANT IS TO BE RELOCATED CORE DRILL 12" HDPE 35.45 LF 12" HDPE @ 6.99% TEE 12" HDPE TEE 12" RCP 92.88 INV. 92.03 INV. 90.60 INV. 90.47 INV. 12" TEE INV=5084.21 28.27 LF 12" HDPE @ 1.0% 25.65 LF 12" HDPE @ 1.0% 20.07 LF 12" HDPE @ 1.0% 24" BASIN COVERED LID INV.=78.22 12" TEE 12" TEE INV.=78.57 INV.=78.76 2' SIDEWALK CHASE 95.45 INV. 95.38 INV. 94.60 INV. 94.54 INV. 89.45 INV. 89.38 INV. 88.65 INV. 88.57 2' SIDEWALK INV. CHASE 45.12 LF HDPE @ 1.75% 2' CURB CUT (TYP X3) SEE SEPARATE L.I.D. PLAN SET FOR SUBDRAIN DETAILS S1 0.560 0.43 8.0 LF 8" HDPE @ 2.05% 93.86 INV. 93.69 INV. 4' VALLEY PAN 24" ADS AREA DRAIN RIM: 5083.22 INV: 5081.22 87.11 LF 12" HDPE @ 1.75% 12" TEE INV: 5080.43 12" FES INV: 5078.90 EXISTING MANHOLE STORM C PIPE - (59) NORTH 0 15' 30' 60' 90' SCALE: 1"= 30'-0" MATCHLINE (SEE SHEET 6 OF 9) 1-800-922-1987 NOTES 1. SEE SHEET 5 FOR DRAINAGE DATA SUMMARY TABLE 2. SEE SHEETS 19 - 21 FOR STORM DRAIN PLAN & PROFILES. MATCHLINE (SAME SHEET) MATCHLINE (SAME SHEET) LEGEND: DRAINAGE BASIN I.D. DESIGN POINT OVERLAND FLOW DIRECTION # # 0.000 0.00 MINOR STORM RUNOFF COEFFICIENT DRAINAGE BASIN AREA (AC) CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C2.0_Drainage Plans.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 DRAINAGE PLAN SOUTH 6 6 SOUTH WALL OF INLET BOX TO ACCEPT PIPING FROM PROPOSED DEVELOPMENT STMH A2 W/ NEENAH R-2553 GRATE RIM EL. = 5080.33 INV. EL. (W) = 5075.30 INV. EL. (E) = 5075.10 24" ADS AREA DRAIN RIM: 5098.25 INV: 5096.25 24" ADS AREA DRAIN RIM: 5093.00 INV: 5091.00 24" ADS AREA DRAIN RIM: 5085.25 INV: 5083.25 24" ADS AREA DRAIN RIM: 5080.25 INV: 5078.25 24" ADS AREA DRAIN RIM: 5098.25 INV: 5095.30 12" TEE INV: 5089.90 12" TEE INV: 5082.76 24" ADS AREA DRAIN RIM: 5079.91 INV: 5077.45 24" ADS AREA DRAIN RIM: 5098.25 INV: 5095.79 24" ADS AREA DRAIN RIM: 5098.25 INV: 8093.60 24" ADS AREA DRAIN RIM: 5094.20 INV: 5090.81 24" ADS AREA DRAIN RIM: 5092.34 24" ADS AREA DRAIN RIM: 5092.76 INV: 5086.60 24" ADS AREA DRAIN RIM: 5088.15 INV: 5083.50 24" ADS AREA DRAIN RIM: 5084.85 INV: 5081.13 24" ADS AREA DRAIN RIM: 5084.50 INV: 5080.18 24" ADS AREA DRAIN RIM: 5094.25 INV: 5090.22 24" ADS AREA DRAIN RIM: 5094.25 INV: 5092.25 25.00 LF 12" HDPE @ 4.07% 45.82 LF 12" HDPE @ 1.00% 47.06 LF 12" HDPE @ 1.00% 46.83 LF 12" HDPE @ 3.64% 76.60 LF 12" HDPE @ 3.64% 76.12 LF 12" HDPE @ 1.16% 39.91 LF 12" HDPE @ 4.96% 36.83 LF 12" HDPE @ 6.05% 64.60 LF 12" HDPE @ 3.67% 23.78 LF 12" HDPE @ 0.51% 71.42 LF 12" HDPE @ 0.51% 79.12 LF 12" HDPE @ 1.20% 21.96 LF 12" HDPE @ 2.55% 68.75 LF 12" HDPE @ 0.33% 12" TEE INV: 5078.02 34.29 LF 12" HDPE @ 6.27% EXIST. 24" RCP EXIST. 36" RCP 12" ELBOW INV: 5083.13 12" ELBOW INV: 5090.79 37.30 LF 12" HDPE @ 5.78% 63.98 LF 12" HDPE @ 2.00% 12" HDPE INV: 5074.48 12" ELBOW INV: 5091.23 25.00 LF 12" HDPE @ 4.07% SEE SEPARATE L.I.D. PLAN SET FOR SUBDRAIN DETAILS S3 0.235 0.29 N6 0.830 0.71 N7 0.900 0.25 OS-1 0.401 0.61 18.42 LF 12" HDPE @ 1.16% NORTH 0 15' 30' 60' 90' SCALE: 1"= 30'-0" MATCHLINE (SEE SHEET 7 OF 9) DRAINAGE DATA SUMMARY TABLE 1-800-922-1987 LEGEND: DRAINAGE BASIN I.D. DESIGN POINT OVERLAND FLOW DIRECTION # # 0.000 0.00 MINOR STORM RUNOFF COEFFICIENT DRAINAGE BASIN AREA (AC) CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C2.0_Drainage Plans.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 NOTES 1. SEE SHEETS 19 - 21 FOR STORM DRAIN PLAN & PROFILES. DRAINAGE PLAN NORTH 5 5 MATERIALS, CONCRETE TRUCK WASHOUT, CHEMICALS, OIL AND GAS PRODUCTS, LITTER, AND SANITARY WASTE. THE DEVELOPER SHALL AT ALL TIMES TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THE PROPER CONTAINMENT AND DISPOSAL OF POLLUTANTS ON THE SITE IN ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. (14.) A DESIGNATED AREA SHALL BE PROVIDED ON SITE FOR CONCRETE TRUCK CHUTE WASHOUT. THE AREA SHALL BE CONSTRUCTED SO AS TO CONTAIN WASHOUT MATERIAL AND LOCATED AT LEAST FIFTY (50) FEET AWAY FROM ANY WATERWAY DURING CONSTRUCTION. UPON COMPLETION OF CONSTRUCTION ACTIVITIES THE CONCRETE WASHOUT MATERIAL WILL BE REMOVED AND PROPERLY DISPOSED OF PRIOR TO THE AREA BEING RESTORED. (15.) TO ENSURE THAT SEDIMENT DOES NOT MOVE OFF OF INDIVIDUAL LOTS ONE OR MORE OF THE FOLLOWING SEDIMENT/EROSION CONTROL BMPS SHALL BE INSTALLED AND MAINTAINED UNTIL THE LOTS ARE SUFFICIENTLY STABILIZED, AS DETERMINED BY THE EROSION CONTROL INSPECTOR. (A.) ALONG LOT PERIMETER. (B.) OTHER LOCATIONS, IF NEEDED. (16.) CONDITIONS IN THE FIELD MAY WARRANT EROSION CONTROL MEASURES IN ADDITION TO WHAT IS SHOWN ON THESE PLANS. THE DEVELOPER SHALL IMPLEMENT WHATEVER MEASURES ARE DETERMINED NECESSARY, AS DIRECTED BY THE CITY/COUNTY. Mobilization Fdn. Excav'n Site Grading Vertical Const. Flatwork Inst. Landscaping Demobilization Best Management Practices (BMP's) Structural "Installation" Silt Fence Vehicle Tracking Pad Inlet Protection (Any existing inlets downstream of site) Sediment Trap / Filter (in Detention Basin) Contour Furrows (Ripping / Disking) Flow Barriers / Wattle Dikes Riprap Armoring *All BMP's are to be removed once construction is complete Vegetative Temporary Seeding / Planting Any time the site will sit dormant longer than 30 days. Mulching / Sealant Any time the site will sit dormant longer than 30 days. Sod Installation Permanent Seeding / Planting Rolled Products (Netting / Blankets / Mats) Any time the site will sit dormant longer than 30 days. THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: T:\Projects\1000 General\1053 TFG\1053-001 RidgewoodHills4th\DWGS\C5.0_Erosion Control Plan.dwg PLOT DATE: 11/19/2013 7:34 AM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE RD & TRIANGLE FORT COLLINS, COLORADO 111-122FC AUG 07, 2014 FP 41 EROSION CONTROL PLAN 4 4 6. THE TYPE, SIZE, LOCATION AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK BEFORE COMMENCING NEW CONSTRUCTION. THE DEVELOPER SHALL BE RESPONSIBLE FOR UNKNOWN UNDERGROUND UTILITIES. 7. THE ENGINEER SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) AT 1-800-922-1987, AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING EXCAVATION OR GRADING, TO HAVE ALL REGISTERED UTILITY LOCATIONS MARKED. OTHER UNREGISTERED UTILITY ENTITIES (I.E. DITCH/IRRIGATION COMPANY) ARE TO BE LOCATED BY CONTACTING THE RESPECTIVE REPRESENTATIVE. UTILITY SERVICE LATERALS ARE ALSO TO BE LOCATED PRIOR TO BEGINNING EXCAVATION OR GRADING. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 8. THE DEVELOPER SHALL BE RESPONSIBLE FOR PROTECTING ALL UTILITIES DURING CONSTRUCTION AND FOR COORDINATING WITH THE APPROPRIATE UTILITY COMPANY FOR ANY UTILITY CROSSINGS REQUIRED. 9. IF A CONFLICT EXISTS BETWEEN EXISTING AND PROPOSED UTILITIES AND/OR A DESIGN MODIFICATION IS REQUIRED, THE DEVELOPER SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. DESIGN MODIFICATION(S) MUST BE APPROVED BY THE CITY OF FORT COLLINS PRIOR TO BEGINNING CONSTRUCTION. 10. THE DEVELOPER SHALL COORDINATE AND COOPERATE WITH THE CITY OF FORT COLLINS, AND ALL UTILITY COMPANIES INVOLVED, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION AND WITH A MINIMUM DISRUPTION OF SERVICE. THE DEVELOPER SHALL BE RESPONSIBLE FOR CONTACTING, IN ADVANCE, ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE AS WELL AS THE UTILITY COMPANIES. 11. NO WORK MAY COMMENCE WITHIN ANY PUBLIC STORM WATER, SANITARY SEWER OR POTABLE WATER SYSTEM UNTIL THE DEVELOPER NOTIFIES THE UTILITY PROVIDER. NOTIFICATION SHALL BE A MINIMUM OF 2 WORKING DAYS PRIOR TO COMMENCEMENT OF ANY WORK. AT THE DISCRETION OF THE WATER UTILITY PROVIDER, A PRE-CONSTRUCTION MEETING MAY BE REQUIRED PRIOR TO COMMENCEMENT OF ANY WORK. 12. THE DEVELOPER SHALL SEQUENCE INSTALLATION OF UTILITIES IN SUCH A MANNER AS TO MINIMIZE POTENTIAL UTILITY CONFLICTS. IN GENERAL, STORM SEWER AND SANITARY SEWER SHOULD BE CONSTRUCTED PRIOR TO INSTALLATION OF THE WATER LINES AND DRY UTILITIES. 13. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY. 14. A STATE CONSTRUCTION DEWATERING WASTEWATER DISCHARGE PERMIT IS REQUIRED IF DEWATERING IS REQUIRED IN ORDER TO INSTALL UTILITIES OR WATER IS DISCHARGED INTO A STORM SEWER, CHANNEL, IRRIGATION DITCH OR ANY WATERS OF THE UNITED STATES. 15. THE DEVELOPER SHALL COMPLY WITH ALL TERMS AND CONDITIONS OF THE COLORADO PERMIT FOR STORM WATER DISCHARGE (CONTACT COLORADO DEPARTMENT OF HEALTH, WATER QUALITY CONTROL DIVISION, (303) 692-3590), THE STORM WATER MANAGEMENT PLAN, AND THE EROSION CONTROL PLAN. 16. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S). 17. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS, CERTIFICATION OF THE DRAINAGE FACILITIES, BY A REGISTERED ENGINEER, MUST BE SUBMITTED TO AND APPROVED BY THE STORMWATER UTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SINGLE FAMILY UNITS. FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDING PERMITS IN EXCESS OF THOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT. 18. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES OR INJURIES SUSTAINED IN THIS DEVELOPMENT AS A RESULT OF GROUNDWATER SEEPAGE, WHETHER RESULTING FROM GROUNDWATER FLOODING, STRUCTURAL DAMAGE OR OTHER DAMAGE UNLESS SUCH DAMAGE OR INJURIES ARE SUSTAINED AS A RESULT OF THE CITY OF FORT COLLINS FAILURE TO PROPERLY MAINTAIN ITS WATER, WASTEWATER, AND/OR STORM DRAINAGE FACILITIES IN THE DEVELOPMENT. 19. ALL RECOMMENDATIONS OF THE FINAL DRAINAGE AND EROSION CONTROL STUDY,"FINAL EROSION CONTROL STUDY FOR "ASPEN HEIGHTS" BY OWEN CONSULTING GROUP INC., SHALL BE FOLLOWED AND IMPLEMENTED. 20. TEMPORARY EROSION CONTROL DURING CONSTRUCTION SHALL BE PROVIDED AS SHOWN ON THE EROSION CONTROL PLAN. ALL EROSION CONTROL MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE DEVELOPER, UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS IS STABILIZED WITH HARD SURFACE OR LANDSCAPING. 21. THE DEVELOPER SHALL BE RESPONSIBLE FOR INSURING THAT NO MUD OR DEBRIS SHALL BE TRACKED ONTO THE EXISTING PUBLIC STREET SYSTEM. MUD AND DEBRIS MUST BE REMOVED WITHIN 24 HOURS BY AN APPROPRIATE MECHANICAL METHOD (I.E. MACHINE BROOM SWEEP, LIGHT DUTY FRONT-END LOADER, ETC.) OR AS APPROVED BY THE CITY OF FORT COLLINS STREET INSPECTOR. 22. NO WORK MAY COMMENCE WITHIN ANY IMPROVED OR UNIMPROVED PUBLIC RIGHT-OF-WAY UNTIL A RIGHT-OF-WAY PERMIT OR DEVELOPMENT CONSTRUCTION PERMIT IS OBTAINED, IF APPLICABLE. 23. THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FOR ALL APPLICABLE AGENCIES PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DEVELOPER SHALL NOTIFY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR (FORT COLLINS - 221-6605) AND THE CITY OF FORT COLLINS EROSION CONTROL INSPECTOR (FORT COLLINS - 221-6700) AT LEAST 2 WORKING DAYS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY, OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS. IF THE CITY OF FORT COLLINS ENGINEER IS NOT AVAILABLE AFTER PROPER NOTICE OF CONSTRUCTION ACTIVITY HAS BEEN PROVIDED, THE DEVELOPER MAY COMMENCE WORK IN THE ENGINEERS ABSENCE. HOWEVER, THE CITY OF FORT COLLINS RESERVES THE RIGHT NOT TO ACCEPT THE IMPROVEMENT IF SUBSEQUENT TESTING REVEALS AN IMPROPER INSTALLATION. 24. THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING SOILS TESTS WITHIN THE PUBLIC RIGHT-OF-WAY AFTER RIGHT OF WAY GRADING AND ALL UTILITY TRENCH WORK IS COMPLETE AND PRIOR TO THE PLACEMENT OF CURB, GUTTER, SIDEWALK AND PAVEMENT. IF THE FINAL SOILS/PAVEMENT DESIGN REPORT DOES NOT CORRESPOND WITH THE RESULTS OF THE ORIGINAL GEOTECHNICAL REPORT, THE DEVELOPER SHALL BE RESPONSIBLE FOR A RE-DESIGN OF THE SUBJECT PAVEMENT SECTION OR, THE DEVELOPER MAY USE THE CITY OF FORT COLLINS'S DEFAULT PAVEMENT THICKNESS SECTION(S). REGARDLESS OF THE OPTION USED, ALL FINAL SOILS/PAVEMENT DESIGN REPORTS SHALL BE PREPARED BY A LICENSED PROFESSIONAL ENGINEER. THE FINAL REPORT SHALL BE SUBMITTED TO THE INSPECTOR A MINIMUM OF 10 WORKING DAYS PRIOR TO PLACEMENT OF BASE AND ASPHALT. PLACEMENT OF CURB, GUTTER, SIDEWALK, BASE AND ASPHALT SHALL NOT OCCUR UNTIL THE CITY OF FORT COLLINS ENGINEER APPROVES THE FINAL REPORT. 25. THE CONTRACTOR SHALL HIRE A LICENSED ENGINEER OR LAND SURVEYOR TO SURVEY THE CONSTRUCTED ELEVATIONS OF THE STREET SUBGRADE AND THE GUTTER FLOWLINE AT ALL INTERSECTIONS, INLETS, AND OTHER LOCATIONS REQUESTED BY THE CITY OF FORT COLLINS INSPECTOR. THE ENGINEER OR SURVEYOR MUST CERTIFY IN A LETTER TO THE CITY OF FORT COLLINS THAT THESE ELEVATIONS CONFORM TO THE APPROVED PLANS AND SPECIFICATIONS. ANY DEVIATIONS SHALL BE NOTED IN THE LETTER AND THEN RESOLVED WITH THE CITY OF FORT COLLINS BEFORE INSTALLATION OF BASE COURSE OR ASPHALT WILL BE ALLOWED ON THE STREETS. 26. ALL UTILITY INSTALLATIONS WITHIN OR ACROSS THE ROADBED OF NEW RESIDENTIAL ROADS MUST BE COMPLETED PRIOR TO THE FINAL STAGES OF ROAD CONSTRUCTION. FOR THE PURPOSES OF THESE STANDARDS, ANY WORK EXCEPT C/G ABOVE THE SUBGRADE IS CONSIDERED FINAL STAGE WORK. ALL SERVICE LINES MUST BE STUBBED TO THE PROPERTY LINES AND MARKED SO AS TO REDUCE THE EXCAVATION NECESSARY FOR BUILDING CONNECTIONS. 27. PORTIONS OF LARIMER COUNTY ARE WITHIN OVERLAY DISTRICTS. THE LARIMER COUNTY FLOODPLAIN RESOLUTION SHOULD BE REFERRED TO FOR ADDITIONAL CRITERIA FOR ROADS WITHIN THESE DISTRICTS. 28. ALL ROAD CONSTRUCTION IN AREAS DESIGNATED AS WILD FIRE HAZARD AREAS SHALL BE DONE IN ACCORDANCE WITH THE CONSTRUCTION CRITERIA AS ESTABLISHED IN THE WILD FIRE HAZARD AREA MITIGATION REGULATIONS IN FORCE AT THE TIME OF FINAL PLAT APPROVAL. 29. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION, THE CONTRACTOR SHALL CONTACT THE CITY OF FORT COLLINS FORESTER TO SCHEDULE A SITE INSPECTION FOR ANY TREE REMOVAL REQUIRING A PERMIT. 30. THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO, EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY. REFER TO OSHA PUBLICATION 2226, EXCAVATING AND TRENCHING. 31. THE DEVELOPER SHALL SUBMIT A CONSTRUCTION TRAFFIC CONTROL PLAN, IN ACCORDANCE WITH MUTCD, TO THE APPROPRIATE RIGHT-OF-WAY AUTHORITY. (CITY OF FORT COLLINS, COUNTY OR STATE), FOR APPROVAL, PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN, OR AFFECTING, THE RIGHT-OF-WAY. THE DEVELOPER SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY THE CONSTRUCTION ACTIVITIES. 32. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION THAT WILL AFFECT TRAFFIC SIGNS OF ANY TYPE, THE CONTRACTOR SHALL CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS DEPARTMENT, WHO WILL TEMPORARILY REMOVE OR RELOCATE THE SIGN AT NO COST TO THE CONTRACTOR; HOWEVER, IF THE CONTRACTOR MOVES THE TRAFFIC SIGN THEN THE CONTRACTOR WILL BE CHARGED FOR THE LABOR, MATERIALS AND EQUIPMENT TO REINSTALL THE SIGN AS NEEDED. 33. THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR THE INITIAL INSTALLATION OF TRAFFIC SIGNING AND STRIPING FOR THE DEVELOPMENT RELATED TO THE DEVELOPMENT'S LOCAL STREET OPERATIONS. IN ADDITION, THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR TRAFFIC SIGNING AND STRIPING RELATED TO DIRECTING TRAFFIC ACCESS TO AND FROM THE DEVELOPMENT. 34. THERE SHALL BE NO SITE CONSTRUCTION ACTIVITIES ON SATURDAYS, UNLESS SPECIFICALLY APPROVED BY THE CITY OF FORT COLLINS ENGINEER, AND NO SITE CONSTRUCTION ACTIVITIES ON SUNDAYS OR HOLIDAYS, UNLESS THERE IS PRIOR WRITTEN APPROVAL BY THE CITY OF FORT COLLINS. 35. THE DEVELOPER IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS, SHOWN ON THESE DRAWINGS, OR DESIGNATED TO BE PROVIDED, INSTALLED, OR CONSTRUCTED, UNLESS SPECIFICALLY NOTED OTHERWISE. 36. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. IF PERTINENT DIMENSIONS ARE NOT SHOWN, CONTACT THE DESIGNER FOR CLARIFICATION, AND ANNOTATE THE DIMENSION ON THE AS-BUILT RECORD DRAWINGS. 37. THE DEVELOPER SHALL HAVE, ONSITE AT ALL TIMES, ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND A COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB. 38. IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE DEVELOPER SHALL CONTACT THE DESIGNER AND THE CITY OF FORT COLLINS ENGINEER IMMEDIATELY. 39. THE DEVELOPER SHALL BE RESPONSIBLE FOR RECORDING AS-BUILT INFORMATION ON A SET OF RECORD DRAWINGS KEPT ON THE CONSTRUCTION SITE, AND AVAILABLE TO THE CITY OF FORT COLLINS'S INSPECTOR AT ALL TIMES. UPON COMPLETION OF THE WORK, THE CONTRACTOR(S) SHALL SUBMIT RECORD DRAWINGS TO THE CITY OF FORT COLLINS ENGINEER. 40. PROJECT BENCHMARKS:ELEVATIONS ARE BASED ON THE CITY OF FORT COLLINS BENCHMARK NO. 42-97, WITH A PUBLISHED ELEVATION OF 4966.75 AND CITY OF FORT COLLINS BENCHMARK NO. 1-00, ELEVATION OF 4965.57 (NGVD 1929 UNADJUSTED). 41. ALL STATIONING IS BASED ON CENTERLINE OF ROADWAYS EXCEPT AT FLOWLINE PROFILES OR UNLESS OTHERWISE NOTED. 42. DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS EXISTING FENCES, TREES, STREETS, SIDEWALKS, CURBS AND GUTTERS, LANDSCAPING, STRUCTURES, AND IMPROVEMENTS DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED IN LIKE KIND AT THE DEVELOPER'S EXPENSE, UNLESS OTHERWISE INDICATED ON THESE PLANS, PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 43. WHEN AN EXISTING ASPHALT STREET MUST BE CUT, THE STREET MUST BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ITS ORIGINAL CONDITION. THE ORIGINAL STREET CONDITION SHALL BE DOCUMENTED BY THE CITY OF FORT COLLINS CONSTRUCTION INSPECTOR BEFORE ANY CUTS ARE MADE. PATCHING SHALL BE DONE IN ACCORDANCE WITH THE CITY OF FORT COLLINS STREET REPAIR STANDARDS. THE FINISHED PATCH SHALL BLEND IN SMOOTHLY INTO THE EXISTING SURFACE. ALL LARGE PATCHES SHALL BE PAVED WITH AN ASPHALT LAY-DOWN MACHINE. IN STREETS WHERE MORE THAN ONE CUT IS MADE, AN OVERLAY OF THE ENTIRE STREET WIDTH, INCLUDING THE PATCHED AREA, MAY BE REQUIRED. THE DETERMINATION OF NEED FOR A COMPLETE OVERLAY SHALL BE MADE BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER AND/OR THE CITY OF FORT COLLINS INSPECTOR AT THE TIME THE CUTS ARE MADE. 44. UPON COMPLETION OF CONSTRUCTION, THE SITE SHALL BE CLEANED AND RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED BEFORE CONSTRUCTION, OR TO THE GRADES AND CONDITION AS REQUIRED BY THESE PLANS. 45. STANDARD HANDICAP RAMPS ARE TO BE CONSTRUCTED AT ALL CURB RETURNS AND AT ALL "T" INTERSECTIONS. 46. AFTER ACCEPTANCE BY THE CITY OF FORT COLLINS, PUBLIC IMPROVEMENTS DEPICTED IN THESE PLANS SHALL BE GUARANTEED TO BE FREE FROM MATERIAL AND WORKMANSHIP DEFECTS FOR A MINIMUM PERIOD OF TWO YEARS FROM THE DATE OF ACCEPTANCE. 47. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF ROADWAY AND APPURTENANT IMPROVEMENTS, INCLUDING STORM DRAINAGE STRUCTURES AND PIPES, FOR THE FOLLOWING PRIVATE STREETS: 48. APPROVED VARIANCES ARE LISTED AS FOLLOWS: NONE GENERAL NOTES 3 3 AND REPAIRED OR RECONSTRUCTED AS NECESSARY IN ORDER TO ENSURE THE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. B. REMAIN IN PLACE UNTIL SUCH TIME AS ALL THE SURROUNDING DISTURBED AREAS ARE SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. C. BE REMOVED AFTER THE SITE HAS BEEN SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. WHEN TEMPORARY EROSION CONTROL MEASURES ARE REMOVED, THE DEVELOPER SHALL BE RESPONSIBLE FOR THE CLEAN UP AND REMOVAL OF ALL SEDIMENT AND DEBRIS FROM ALL DRAINAGE INFRASTRUCTURE AND OTHER PUBLIC FACILITIES. THE CONTRACTOR SHALL CLEAN UP ANY INADVERTENT DEPOSITED MATERIAL IMMEDIATELY AND MAKE SURE STREETS ARE FREE OF ALL MATERIALS BY THE END OF EACH WORKING DAY. ALL RETAINED SEDIMENTS, PARTICULARLY THOSE ON PAVED ROADWAY SURFACES, SHALL BE REMOVED AND DISPOSED OF IN A MANNER AND LOCATION SO AS NOT TO CAUSE THEIR RELEASE INTO ANY WATERS OF THE UNITED STATES. NO SOIL STOCKPILE SHALL EXCEED TEN (10 FEET IN HEIGHT. ALL SOIL STOCKPILES SHALL BE PROTECTED FROM SEDIMENT TRANSPORT BY SURFACE ROUGHENING, WATERING, AND PERIMETER SILT FENCING. ANY SOIL STOCKPILE REMAINING AFTER THIRTY (30) DAYS SHALL BE SEEDED AND MULCHED. THE STORMWATER VOLUME CAPACITY OF DETENTION PONDS WILL BE RESTORED AND STORM SEWER LINES WILL BE CLEANED UPON COMPLETION OF THE PROJECT AND BEFORE TURNING THE MAINTENANCE OVER THE CITY OF FORT COLLINS OR HOMEOWNERS ASSOCIATION (HOA). CITY ORDINANCE AND COLORADO DISCHARGE PERMIT SYSTEM (CDPS) REQUIREMENTS MAKE IT UNLAWFUL TO DISCHARGE OR ALLOW THE DISCHARGE OF ANY POLLUTANT OR CONTAMINATED WATER FROM CONSTRUCTION SITES. POLLUTANTS INCLUDE, BUT ARE NOT LIMITED TO DISCARDED BUILDINGS MATERIALS, CONCRETE TRUCK WASHOUT, CHEMICALS, OIL AND GAS PRODUCTS, LITTER, AND SANITARY WASTE. THE DEVELOPER SHALL AT ALL TIMES TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THE PROPER CONTAINMENT AND DISPOSAL OF POLLUTANTS ON THE SITE IN ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. A DESIGNATED AREA SHALL BE PROVIDED ON SITE FOR CONCRETE TRUCK CHUTE WASHOUT. THE AREA SHALL BE CONSTRUCTED SO AS TO CONTAIN WASHOUT MATERIAL AND LOCATED AT LEAST FIFTY (50) FEET AWAY FROM ANY WATERWAY DURING CONSTRUCTION. UPON COMPLETION OF CONSTRUCTION ACTIVITIES THE CONCRETE WASHOUT MATERIAL WILL BE REMOVED AND PROPERTY DISPOSED OF PRIOR TO THE AREA BEING RESTORED. CONDITIONS IN THE FIELD MAY WARRANT EROSION CONTROL MEASURES IN ADDITION TO WHAT IS SHOWN ON THESE PLANS. THE DEVELOPER SHALL IMPLEMENT WHATEVER MEASURES ARE DETERMINED NECESSARY, AS DIRECTED BY THE CITY OF FORT COLLINS. ALL VEHICLE TRACKING CONTROL PAD SHALL BE INSTALLED WHEN NEEDED FOR CONSTRUCTION EQUIPMENT, INCLUDING BUT NOT LIMITED TO PERSONAL VEHICLES EXITING EXISTING ROADWAYS. NO EARTHEN MATERIALS, I.E. STONE, DIRT, ETC. SHALL BE PLACED IN THE CURB AND GUTTER OR ROADWAY AS A RAMP TO ACCESS TEMPORARY STOCKPILES, STAGING AREAS, CONSTRUCTION MATERIALS, CONCRETE WASHOUT AREAS, AND/OR BUILDING SITES. B. STREET IMPROVEMENTS NOTES: 1. ALL STREET CONSTRUCTION IS SUBJECT TO THE GENERAL NOTES ON THESE PLANS AS WELL AS THE STREET IMPROVEMENTS NOTES LISTED HERE. 2. A PAVING SECTION DESIGN, SIGNED AND STAMPED BY A COLORADO LICENSED TRAFFIC ENGINEER, MUST BE SUBMITTED TO THE CITY OF FORT COLLINS TRAFFIC ENGINEER FOR APPROVAL, PRIOR TO ANY STREET CONSTRUCTION ACTIVITY, (FULL DEPTH ASPHALT SECTIONS ARE NOT PERMITTED AT A DEPTH GREATER THAN 8 INCHES OF ASPHALT). THE JOB MIX SHALL BE SUBMITTED FOR APPROVAL PRIOR TO PLACEMENT OF ANY ASPHALT. 2. ALL RECOMMENDATIONS OF THE FINAL DRAINAGE AND EROSION CONTROL STUDY "ASPEN HEIGHTS" BY OWEN CONSULTING GROUP INC. SHALL BE FOLLOWED AND IMPLEMENTED. 3. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS, CERTIFICATION OF THE DRAINAGE FACILITIES, BY A REGISTERED ENGINEER, MUST BY SUBMITTED TO AND APPROVED BY THE STORMWATER UTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SINGLE FAMILY UNITS. FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BY SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDING PERMITS IN EXCESS OF THOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT. E. WATERLINE NOTES: 1. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITY DEPARTMENT. F. SEWER MAIN NOTES AND SPECIFICATIONS: 1. SANITARY SEWER MAIN CONSTRUCTION SHALL CONFORM TO THE CITY OF FORT COLLINS' MOST RECENT SANITARY SEWER SPECIFICATIONS. A COPY OF THE SPECIFICATIONS MAY BE OBTAINED FROM THE CITY OF FORT COLLINS WATER/WASTEWATER UTILITY DEPARTMENT AT 700 NORTH WOOD STREET IN FORT COLLINS. 2. SANITARY SEWER PIPE MATERIAL SPECIFICATIONS ARE AS FOLLOWS: A. POLYVINYL CHLORIDE PIPE (PVC) - ALL PVC SEWER PIPE SHALL BE UNPLASTICIZED POLYVINYL CHLORIDE PLASTIC GRAVITY SEWER PIPE "J-M RING-TITE PVC SEWER", "CERTAIN TEED FLUID-TITE PVC GRAVITY SEWER PIPE", OR APPROVED EQUAL WITH INTEGRAL WALL BELL AND SPIGOT JOINTS. PIPE SHALL BE MADE FROM MATERIALS CONFORMING TO ASTM D1784. THE PIPE SHALL BE SUITABLE FOR USE AS A GRAVITY SEWER CONDUIT WITH PROVISIONS MADE FOR CONTRACTION AND EXPANSION AT EACH JOINT WITH A RUBBER RING. ALL GRAVITY SEWER PIPE AND FITTINGS SHALL MEET THE REQUIREMENTS OF ASTM D3034 AND HAVE A STANDARD DIMENSION RATIO (SDR) OF 35 OR LESS. THE MINIMUM PIPE STIFFNESS AT 5% DEFLECTION SHALL BE 46 PSI WHEN TESTED IN ACCORDANCE WITH ASTM D24212. 3. ALL SEWER LINES SHALL BE TESTED BY THE CONTRACTOR FOR WATER TIGHTNESS PRIOR TO BEING PLACED INTO SERVICE. ALL SERVICE CONNECTIONS SHALL BE COMPLETED PRIOR TO TESTING. TESTING SHALL BE DONE BY AIR PRESSURE TESTING IN ACCORDANCE WITH THE CITY'S SPECIFICATIONS. IF ANY LEAKS ARE DISCOVERED THEY SHALL BE LOCATED AND REPAIRED AT THE CONTRACTOR'S EXPENSE AND THE LINE RE-TESTED. ALL TESTING SHALL BE OBSERVED BY THE CITY OF FORT COLLINS INSPECTOR. 4. DISTANCES SHOWN FOR SANITARY SEWER ARE THE HORIZONTAL DISTANCES FROM CENTER OF MANHOLE TO CENTER OF MANHOLE. THEREFORE, DISTANCES SHOWN ON THE PLANS ARE APPROXIMATE AND COULD VARY DUE TO VERTICAL ALIGNMENT AND MANHOLE WIDTHS. 5. SANITARY SEWER SERVICE WYES SHALL BE LOCATED A MINIMUM OF 10 FEET FROM ANY WATER SERVICE. 6. RIM ELEVATIONS SHOWN ARE APPROXIMATED ONLY AND ARE NOT TO BE TAKEN AS FINAL ELEVATIONS. THE CONTRACTOR SHALL USE PRE CAST CONCRETE ADJUSTMENT RINGS TO ADJUST THE MANHOLE FRAME TO MATCH THE FINISHED STREET SURFACE, SUCH THAT THERE ARE NO MORE THAN SIXTEEN (16) INCHES FROM FINISHED GRADE TO THE TOP OF THE CONE SECTION. 7. MANHOLE COVERS SHALL BE ALIGNED TO PROVIDE A MINIMUM OF THREE (3) FEET CLEARANCE BETWEEN THE MANHOLE RING AND THE LIP OF GUTTER. 8. ALL EXISTING AND PROPOSED MANHOLE COVERS SHALL BE ADJUSTED TO 1/4 INCH BELOW THE FINISHED STREET SURFACE. 9. THE CONTRACTOR SHALL VERIFY THE HORIZONTAL AND VERTICAL ALIGNMENT OF ALL POINTS OF CONNECTION AND UTILITY CROSSINGS PRIOR TO INSTALLING ANY SEWER MAIN PIPE. IF A DESIGN MODIFICATION IS REQUIRED IT SHALL BE COORDINATED WITH THE ENGINEER AND APPROVED BY THE CITY OF FORT COLLINS. 10. THE CONTRACTOR SHALL CONSTRUCT THE SEWER SERVICES TO THE BACK OF THE UTILITY EASEMENT AND SHALL MARK THE LOCATION OF THE END OF THE SERVICE WITH A 4" X 4" WOOD POST EXTENDING FROM THE SANITARY SEWER SERVICE TO TWO (2) FOOT ABOVE FINISHED GRADE. 11. THE CONTRACTOR SHALL VACUUM TEST ALL SANITARY SEWER MANHOLES PRIOR TO ACCEPTANCE. 12. OUTSIDE DROP OF DROP MANHOLES SHALL BE ENCASED IN CONCRETE PER CITY'S REQUIREMENTS. 13. ALL FOUR INCH (4") SANITARY SEWER LATERALS SHALL BE INSTALLED AT A POSITIVE GRADE OF 2.0% (1/4" PER FOOT) FROM THEIR CONNECTION TO THE SANITARY SEWER MAIN TOWARDS THE PROPOSED STRUCTURE. THIS GRADE SHALL BE HELD TO ACHIEVE THE MAXIMUM DEPTH POSSIBLE FOR THE SANITARY SEWER LATERAL AT THE BUILDING FOUNDATION. A DECREASE OR FLATTENING OF THE GRADE SHALL NOT BE ALLOWED. AN INCREASE OR STEEPENING OF THE GRADE MAY BE ALLOWED IN CERTAIN SITUATIONS ONLY UPON APPROVAL OF THE ENGINEER. 3. WHERE PROPOSED PAVING ADJOINS EXISTING ASPHALT, THE EXISTING ASPHALT SHALL BE SAW CUT, A MINIMUM DISTANCE OF 12 INCHES FROM THE EXISTING EDGE, TO CREATE A CLEAN CONSTRUCTION JOINT. THE DEVELOPER SHALL BE REQUIRED TO REMOVE EXISTING PAVEMENT TO A DISTANCE WHERE A CLEAN CONSTRUCTION JOINT CAN BE MADE. WHEEL CUTS SHALL NOT BE ALLOWED UNLESS APPROVED BY THE CITY OF FORT COLLINS ENGINEER. 4. STREET SUBGRADES SHALL BE SCARIFIED THE TOP 12 INCHES AND RE-COMPACTED PRIOR TO SUBBASE INSTALLATION. NO BASE MATERIAL SHALL BE LAID UNTIL THE SUBGRADE HAS BEEN INSPECTED AND APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. 5. VALVE BOXES AND MANHOLES ARE TO BE BROUGHT UP TO GRADE AT THE TIME OF PAVEMENT PLACEMENT OR OVERLAY. VALVE BOX ADJUSTING RINGS ARE NOT ALLOWED. 6. WHEN AN EXISTING ASPHALT STREET MUST BE CUT, THE STREET MUST BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ITS ORIGINAL CONDITION. THE EXISTING STREET CONDITION SHALL BE DOCUMENTED BY THE INSPECTOR BEFORE ANY CUTS ARE MADE. CUTTING AND PATCHING SHALL BE DONE IN CONFORMANCE WITH CHAPTER 25, RECONSTRUCTION AND REPAIR. THE FINISHED PATCH SHALL BLEND SMOOTHLY INTO THE EXISTING SURFACE. THE DETERMINATION OF NEED FOR A COMPLETE OVERLAY SHALL BE MADE BY THE CITY OF FORT COLLINS ENGINEER. ALL OVERLAY WORK SHALL BE COORDINATED WITH ADJACENT LANDOWNERS SUCH THAT FUTURE PROJECTS DO NOT CUT THE NEW ASPHALT OVERLAY WORK. 7. ALL TRAFFIC CONTROL DEVICES SHALL BE IN CONFORMANCE WITH THESE PLANS OR AS OTHERWISE SPECIFIED IN M.U.T.C.D. (INCLUDING COLORADO SUPPLEMENT) AND AS PER THE RIGHT-OF-WAY WORK PERMIT TRAFFIC CONTROL PLAN. 8. THE DEVELOPER IS REQUIRED TO PERFORM A GUTTER WATER FLOW TEST IN THE PRESENCE OF THE CITY OF )257&2//,16,163(&725$1'35,2572,167$//$7,212)$63+$/7*877(567+$7+2/'025(7+$1ó,1&+ DEEP OR 5 FEET LONGITUDINALLY, OF WATER, SHALL BE COMPLETELY REMOVED AND RECONSTRUCTED TO DRAIN PROPERLY. 9. PRIOR TO PLACEMENT OF H.B.P. OR CONCRETE WITHIN THE STREET AND AFTER MOISTURE/DENSITY TESTS HAVE BEEN TAKEN ON THE SUBGRADE MATERIAL (WHEN A FULL DEPTH SECTION IS PROPOSED) OR ON THE SUBGRADE AND BASE MATERIAL (WHEN A COMPOSITE SECTION IS PROPOSED), A MECHANICAL "PROOF ROLL" WILL BE REQUIRED. THE ENTIRE SUBGRADE AND/OR BASE MATERIAL SHALL BE ROLLED WITH A HEAVILY LOADED VEHICLE HAVING A TOTAL GVW OF NOT LESS THAN 50,000 LBS. AND A SINGLE AXLE WEIGHT OF AT LEAST 18,000 LBS. WITH PNEUMATIC TIRES INFLATED TO NOT LESS THAT 90 P.S.I.G. "PROOF ROLL" VEHICLES SHALL NOT TRAVEL AT SPEEDS GREATER THAN 3 M.P.H. ANY PORTION OF THE SUBGRADE OR BASE MATERIAL WHICH EXHIBITS EXCESSIVE PUMPING OR DEFORMATION, AS DETERMINED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER, SHALL BE REWORKED, REPLACED OR OTHERWISE MODIFIED TO FORM A SMOOTH, NON-YIELDING SURFACE. THE CITY OF FORT COLLINS ENGINEER SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO THE "PROOF ROLL." ALL "PROOF ROLLS" SHALL BE PREFORMED IN THE PRESENCE OF AN INSPECTOR. C. TRAFFIC SIGNS AND PAVEMENT MARKING CONSTRUCTION NOTES: 1. ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THESE PLANS, AS WELL AS THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE. 2. ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMED THERMO-PLASTIC. 3. ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. 4. ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS. 5. ALL LANE LINES FOR CONCRETE PAVEMENT SHOULD BE EPOXY PAINT. 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMENT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER PRIOR TO PERMANENT INSTALLATION OF STRIPING AND SYMBOLS. 7. PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS. 8. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. 9. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. 10. ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS. 11. A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN. 12. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. 13. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. 14. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD, THE CITY OF FORT COLLINS TRAFFIC ENGINEER RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE CITY OF FORT COLLINS TRAFFIC ENGINEER DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS). 15. SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFIC CONTROL DEVICES, FOR ADDITIONAL DETAIL. D. STORM DRAINAGE NOTES: 1. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S). CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL GENERAL NOTES 2 2 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE 30' UE 34.6' 31.4' 30' UE, DE & EAE 30' UE, DE & EAE 30' UE, DE & EAE THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE LANDSCAPE ARCHITECT. ATTN: SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: DRAWN BY: FILE LOCATION: O:\Current Projects\111-Owen Consulting\122FC-Ridgewood\AutoCAD\FP and FUP\DWG\Ridgewood FUP.dwg PLOT DATE: 8/1/2014 1:08 PM PROJECT NUMBER: DATE: PHASE: M. TIMM DEVELOPMENT BILL TIMM 233 CARILLO STREET SANTA BARBARA, CA 93101 (805) 963-0358 RIDGEWOOD HILLS FOURTH FILING AVONDALE ROAD & TRIANGLE DRIVE FORT COLLINS, COLORADO 111-122FC DEC 13, 2013 FP 41 1269 N Cleveland Ave, Loveland CO 80537 (970) 669.3737 design@tfgdesign.com www.tfgdesign.com OVERALL UTILITY PLAN 9 0 30' 60' 120' 180' 9 SCALE: 1"= 60'-0" NORTH CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL NORTH LEGEND PROPOSED STORM DRAIN WITH MANHOLE PROPOSED STORM INLET PROPOSED SANITARY SEWER WITH MANHOLE PROPOSED WATERLINE WITH VALVE & FIRE HYDRANT PROPOSED WATERLINE TAP METER PROPOSED FIRELINE TAP PROPOSED IRRIGATION LINE WITH METER PROPOSED ELECTRIC LINE PROPOSED GAS LINE EXISTING SANITARY SEWER EXISTING WATERLINE EXISTING STORM DRAIN PIPE UTILITY NOTES 1. ALL SANITARY SEWER PIPE IS 8" PVC SDR-35, UNLESS NOTED OTHERWISE.. 2. ALL SANITARY SEWER, WATER AND STORMWATER CONSTRUCTION SHALL CONFORM TO FORT COLLINS SANITATION DISTRICT WASTEWATER AND STORMWATER DEVELOPMENT CONSTRUCTION STANDARDS AND DETAILS. 3. ALL REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III OR BETTER UNLESS NOTED OTHERWISE. 4. ALL WATERLINE TO BE CONSTRUCTED A MINIMUM OF 5' AND A MAXIMUM OF 6' (5' TYPICAL) BELOW FINISHED GRADE UNLESS OTHERWISE NOTED. 5. ALL WATERLINE SERVICES TO BE 2" UNLESS NOTED OTHERWISE. 6. PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN WATER AND SEWER MAINS. 7. SEE GRADING PLANS FOR EASEMENT DELINEATION, DIMENSIONS AND DETAILS. 8. REFER TO GRADING, DRAINAGE AND EROSION CONTROL PLANS FOR FLOODPLAIN INFORMATION. 9. SEE UTILITY DETAIL SHEETS FOR SERVICE CONNECTION DETAILS. 10. REDUCED PRESSURE PRINCIPLE (RP) BACK-FLOW-PREVENTION-DEVICES TO BE INSTALLED ON THE FIRE LINE RISERS AND DOMESTIC WATER SERVICES. 11. TELEPHONE AND CATV TO BE INSTALLED IN COMMON TRENCH WITH POWER. SAN MH N-2 SAN MH N-3 SAN MH N-4 SAN MH S-5 SAN MH S-4 SAN MH S-3 SAN MH S-2 SAN MH S-1 SMH S-7 SAN MH S-6 8" SEWERLINE 8" SEWERLINE 8" SEWERLINE 8" SEWERLINE 8" SEWERLINE 8" SEWERLINE 8" SEWERLINE 8" SEWERLINE 8" SEWERLINE 8" SEWERLINE 8" WATERLINE FIRE HYDRANT 8" WATERLINE 8" WATERLINE 8" WATERLINE FIRE HYDRANT 8" WATERLINE FIRE HYDRANT 8" WATERLINE 8" WATERLINE TEMP. FIRE HYDRANT 8" WATERLINE 8" X 8" TEE 8" X 8" TEE 8" WATERLINE RELOCATE EXIST. FIRE HYDRANT 8" WATERLINE FIRE HYDRANT FIRE HYDRANT 8" WATERLINE 8" WATERLINE 8" WATERLINE FIRE HYDRANT 8" WATERLINE 12" STORM DRAIN 24" STORM DRAIN 12" STORM DRAIN 30" STORM DRAIN 36" STORM DRAIN 12" STORM DRAIN 12" STORM DRAIN 30" STORM DRAIN 12" STORM DRAIN 12" STORM DRAIN 12" STORM SEWER 12" STORM DRAIN 24" STORM DRAIN 12" STORM DRAIN 24" STORM DRAIN 12" STORM DRAIN 30" STORM DRAIN 30" STORM DRAIN 30" STORM DRAIN 8" X 8" TEE 8" WATERLINE 8" WATERLINE 8" WATERLINE 8" WATERLINE 8" WATERLINE 12" STORM DRAIN 12" STORM DRAIN 12" STORM DRAIN 12" STORM DRAIN CONNECT TO EXIST. SEWER SAN MH N-1 12" STORM DRAIN IRRIGATION SERVICE AND METER CONNECT TO EXIST. WATER MAIN 12" STORM DRAIN SAWCUT AND PATCH PER DETAIL 2201 ON SHEET 30 12" STORM DRAIN RECORDER ON AUGUST 4, 2000 AS RECEPTION NO. 2000053189. . . . (WHICH ABOVE DESCRIBED TRACT CONTAINS 10.422 ACRES, MORE OR LESS) INDEX TO DRAWINGS DECEMBER 13, 2013 A PARCEL OF LAND SITUATED IN THE SOUTHEAST QUARTER OF SECTION 14, TOWNSHIP 6 NORTH, RANGE 69 WEST, OF THE 6TH PRINCIPLE MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. UTILITY PLANS FOR SUPPLEMENTAL GENERAL NOTES LEGEND ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE MOST CURRENT SOUTH FORT COLLINS SANITATION DISTRICT UTILITY CONSTRUCTION SPECIFICATIONS AND REQUIREMENTS. ALL WATER DISTRIBUTION SHALL CONFORM TO THE MOST CURRENT FORT COLLINS - LOVELAND WATER DISTRICT UTILITY CONSTRUCTION SPECIFICATIONS AND REQUIREMENTS. ALL WATER LINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS CURRENT TO THE DATE OF CONSTRUCTION. REDUCED PRESSURE PRINCIPLE (RP) BACK-FLOW-PREVENTION-DEVICES TO BE INSTALL ON THE FIRE LINE RISER AND DOMESTIC WATER SERVICES. ALL SANITARY SEWER LINE CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS CURRENT TO THE DATE OF CONSTRUCTION. SEE SHEET 3 FOR THE LARIMER COUNTY URBAN AREA STREET STANDARDS STANDARD GENERAL NOTES AND STANDARD CONSTRUCTION NOTES. LIMITS OF STREET CUTS SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS ARE TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. THE FORT COLLINS - LOVELAND WATER DISTRICT SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. THE PROPERTY OWNER WILL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL ONSITE AND OFFSITE DRAINAGE FACILITIES ASSOCIATED WITH THIS PROJECT THAT ARE OUTSIDE THE PUBLIC RIGHT OF WAY. THIS INCLUDES ALL TRACTS AND PRIVATE DRIVES. A DRAINAGE AND EROSION CONTROL REPORT HAS BEEN PREPARED SPECIFICALLY FOR RIDGEWOOD HILLS. ALL RECOMMENDATIONS INCLUDED IN SAID REPORT SHALL BE CONSIDERED A PART OF THESE GENERAL NOTES AND SPECIFICATIONS AND SHALL BE FOLLOWED DURING CONSTRUCTION. ALL SITE WORK CONSTRUCTION MUST CONFORM TO ADA (AMERICAN DISABILITIES ACT) REQUIREMENTS FOR HANDICAP ACCESS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. CONTRACTOR AND ALL SUBCONTRACTORS TO THOROUGHLY FAMILIARIZE THEMSELVES WITH THESE DOCUMENTS. ALL STORM DRAIN PIPES SHALL BE CLASS III REINFORCED CONCRETE PIPE (RCP) WITH R4 JOINTS MEETING THE REQUIREMENTS OF ASTM STANDARD SPECIFICATION C443, LATEST VERSION, UNLESS OTHERWISE SPECIFIED. PROPOSED STORM DRAIN WITH MANHOLE PROPOSED STORM INLET PROPOSED SANITARY SEWER WITH MANHOLE PROPOSED WATERLINE WITH VALVE & FIRE HYDRANT PROPOSED WATERLINE TAP METER PROPOSED FIRELINE TAP PROPOSED IRRIGATION LINE WITH METER PROPOSED ELECTRIC LINE PROPOSED GAS LINE EXISTING SANITARY SEWER EXISTING WATERLINE EXISTING STORM DRAIN PIPE ROAD OR DRIVE AISLE CENTERLINE BUILDING SETBACK LINE EASEMENT LINE BOUNDARY LINE PROPOSED CONTOUR PROPOSED INDEX CONTOUR