HomeMy WebLinkAboutAVONDALE COTTAGES - FDP - FDP140018 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANS1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
COVER SHEET
08/6/14
N/A
N/A
JTC
RA
1 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
UTILITY PLANS FOR
AVONDALE COTTAGES
A REPLAT OF TRACT L, RIDGEWOOD HILLS P.U.D., FIRST FILING, LOCATED IN THE NORTHEAST
QUARTER OF SECTION 14, TOWNSHIP 6 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN,
CITY OF FORT COLLINS,
COUNTY OF LARIMER, STATE OF COLORADO
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
GENERAL NOTES
08/6/14
N/A
N/A
JTC
RA
2 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
WEST TRILBY ROAD
AVONDALE ROAD
TRACT K
PRIVATE
DRIVE
TRACT K
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
EXISTING & DEMOLITION
08/6/14
1"=20'
N/A
JTC
RA
3 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
0
20'
20 10 20 40
SCALE: 1" =
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
WEST TRILBY ROAD
AVONDALE ROAD
LOT 2
LOT 1
LOT 5
LOT 4
LOT 3
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
TRACT K
PRIVATE
DRIVE
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
UTILITY PLAN
08/6/14
1"=20'
N/A
JTC
RA
4 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
0
20'
20 10 20 40
SCALE: 1" =
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
SANITARY SEWER PLAN & PROFILE
08/6/14
1"=20'
1"=2'
JTC
RA
5 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
0
20'
20 10 20 40
SCALE: 1" =
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
MATCHLINE
sta 10+62.00
MATCHLINE
sta 10+62.00
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
SANITARY SEWER PLAN & PROFILE
08/6/14
1"=20'
1"=2
1"=2'
RA
6 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
0
20'
20 10 20 40
SCALE: 1" =
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
PLAN VIEW
SANITARY SEWER CLEANOUT DETAIL
NTS
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
SANITAY SEWER DETAILS
08/6/14
N/A
N/A
JTC
RA
7 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
WATERLINE DETAILS
08/6/14
N/A
N/A
JTC
RA
8 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
STORM DRAIN PLAN & PROFILE
08/6/14
1"=20'
1"=2'
JTC
RA
9 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
0
20'
20 10 20 40
SCALE: 1" =
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
NOTES:
1. PIPE LENGTHS ARE GIVEN FROM CENTER OF STRUCTURE TO CENTER OF
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
STORM DRAIN PLAN & PROFILE
08/6/14
1"=20'
1"=2'
JTC
RA
10 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
0
20'
20 10 20 40
SCALE: 1" =
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
CITY OF FORT COLLINS
BIORETENTION SAND MEDIA SPECIFICATION
SECTION B-B
PLAN
SECTION A-A
WATER QUALITY OUTLET STRUCTURE
POROUS LANDSCAPE DETENTION AND RETAINING WALL DETAIL
TYPICAL POND CROSS SECTION GEOMEMBRANE LINER/CONCRETE CONNECTION DETAIL
GEOMEMBRANE LINER/ UNDERDRAIN PENETRATION DETAIL
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
STORM DRAIN DETAILS
08/6/14
N/A
N/A
JTC
RA
11 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
STORM SEWER OUTLET
STORM SEWER HEADWALL RIPRAP DETAIL
SECTION B-B
SECTION A-A
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
Storm Drain Details
08/6/14
N/A
N/A
JTC
RA
12 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
LOT 2
LOT 1
LOT 5
LOT 4
LOT 3
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
TRACT K
WEST TRILBY ROAD
AVONDALE ROAD
PRIVATE
DRIVE
LOT 2
LOT 1
LOT 5
LOT 4
LOT 3
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
Drainage & Erosion Control Plan
AVONDALE COTTAGES
08/6/14
1"=X'
N/A
JTC
RA
13 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
EROSION CONTROL DETAILS
08/6/14
N/A
N/A
JTC
RA
14 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
EROSION CONROL DETAILS
08/6/14
N/A
N/A
JTC
RA
15 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
TRACT K
WEST TRILBY ROAD
AVONDALE ROAD
PRIVATE
DRIVE
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
SITE & GRADING PLAN
08/6/14
1"=20'
N/A
JTC
RA
16 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
NOTES:
WALK DEPRESSION @ CORNER
CURB RAMP DETAIL
SIDEWALK CHASE DETAIL
WALK DEPRESSION
CONCRETE PAVING SECTION DETAIL
NTS ASPHALT PATCH DETAIL
NTS
EXPANSION JOINT DETAIL
NTS
CONTRACTION JOIN DETAIL
NTS
CURB RAMP W/ RIPRAP PAD
4' CROSS PAN DETAIL
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
SITE & GRADING DETAILS
08/6/14
N/A
N/A
JTC
RA
17 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
LOT 2
LOT 1
LOT 5
LOT 4
LOT 3
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
PRIVATE
DRIVE
TRACK K
RIDGEWOOD HILLS
P.U.D., FIRST FILING
TRACK M
1ST REPLAT OF
RIDGEWOOD HILLS
P.U.D., FIRST FILING
TRACT K
LOT 204
LOT 203
LOT 202
LOT 201
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
HORIZONTAL CONTROL PLAN
08/6/14
1'=20'
N/A
JTC
RA
18 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
1218 W. Ash, Suite C
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
DATE: PREPARED FOR
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJ. NO. 1192-117-00
AVONDALE COTTAGES
SIGNING & STRIPING DETAILS
08/6/14
N/A
N/A
JTC
RA
19 of 19
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
PHONE: 970.223.4522
FAX: 970.223.4524
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Date
Date
Date
Date
Date
Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
SIGN LEGEND
TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES:
1. ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON SHEET 2
OF THESE PLANS, AS WELL AS THE TRAFFIC SIGNING AND MARKING
CONSTRUCTION NOTES USED HERE.
2. ALL SIGNAGE SHALL BE PER CITY STANDINGS, CDOT AND THESE PANS OR AS
OTHERWISE SPECIFIED IN MUTCD.
3. ALL LANE LINES FOR CONCRETE PAVEMENT SHOULD BE EPOXY PAINT.
-
4. FINAL STRIPING AND SYMBOL LOCATIONS SHALL BE FIELD COORDINATED
WITH OWNER.
5. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION.
6. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION
OF STRIPING OR MARKING.
7. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING
AND PROTECTING ALL UNDERGROUND UTILITIES.
8. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN
UNOBSTRUCTED VIEW OF EACH SIGN.
0
20'
20 10 20 40
SCALE: 1" =
STOP
1. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE
MINIMUM ELEVATIONS REQUIRED FOR THE PROTECTION
FROM THE 100-YR STORM.
2. THE FINISHED GRADE ELEVATIONS SHOWN ARE BASED ON
THE ADJACENT PROPERTY LINE HIGH POINTS AND A
MINIMUM OF 10% TO THE PROPERTY LINE OR 10' AWAY
FOR STRUCTURE. THE ACTUAL FINISHED GRADE AROUND
EACH STRUCTURE WILL VARY BASED ON ADJACENT
PROPERTY LINE GRADES.
3. THE DRIVES WITHIN THE SITE WILL BE PRIVATELY OWNED
AND MAINTAINED. THERE WILL BE NO PUBLIC
MAINTENANCE OF THE DRIVE.
4. OFFSITE GRADING IS LIMITED TO AREAS COVERED BY
EXISTING DRAINAGE AND/OR UTILITY EASEMENTS FOR
THE PURPOSE OF UTILITY OR DRAINAGE CONNECTIONS,
UNLESS OTHERWISE NOTED.
5. SEE LANDSCAPE PLAN FOR REVEGETATION METHODS AND
DETAILS. DURING CONSTRUCTION, ANY SOIL DISTURBED
AND NOT UNDER ACTIVE CONSTRUCTION SHALL BE
SEEDED AND MULCHED PER LCUASS STANDARDS.
6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS
ARE TO BE DETERMINED IN THE FIELD BY CITY ENGINEER
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH
CITY STREET REPAIR STANDARDS
7. A SEPARATE BUILDING PERMIT IS REQUIRED FOR ALL
RETAINING WALLS GREATER THAN 2 FEET HIGH.
8. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS
ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF
FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY STREET REPAIR
STANDARDS.
9. REFERENCE THE "SUBSURFACE EXPLORATION REPORT -
AVONDALE COTTAGES INFRASTRUCTURE", PREPARED BY
EARTH ENGINEERING CONSULTANTS, LLC, DATED APRIL 2,
2014 FOR GEOTECHNICAL ENGINEERING
RECOMMENDATIONS.
0
SCALE: 1" = 15'
15 7.5 15 30
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Parks and Recreation
Traffic Engineer
Stormwater Utility
Water & Wastewater Utility
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
LEGEND
SILT FENCE
INLET PROTECTION
CONSTRUCTION ENTRANCE W/ VEHICLE TRACKING CONTROL
0
20'
20 10 20 40
SCALE: 1" =
DRAINAGE ARROW
BASIN DESIGNATION
BASIN AREA
BASIN COEFFICIENT (5-YR)
DESIGN POINT
CoFC Standard erosion and sediment control notes:
1. THE CITY STORMWATER DEPARTMENT EROSION CONTROL INSPECTOR MUST
BE NOTIFIED AT LEAST 24 HOURS PRIOR TO ANY CONSTRUCTION ON THIS
SITE.
2. ALL REQUIRED BMPS MUST BE INSTALLED PRIOR TO ANY LAND DISTURBING
ACTIVITY (STOCKPILING, STRIPPING, GRADING, ETC). ALL REQUIRED EROSION
CONTROL MEASURES MUST BE INSTALLED AT THE APPROPRIATE TIME IN THE
CONSTRUCTION SEQUENCE AS INDICATED IN THE APPROVED PROJECT
SCHEDULE, CONSTRUCTION PLANS, AND EROSION CONTROL REPORT.
3. PRE-DISTURBANCE VEGETATION SHALL BE PROTECTED AND RETAINED
WHEREVER POSSIBLE. REMOVAL OR DISTURBANCE OF EXISTING VEGETATION
SHALL BE LIMITED TO THE AREA REQUIRED FOR IMMEDIATE CONSTRUCTION
OPERATIONS, AND FOR THE SHORTEST PRACTICAL PERIOD OF TIME.
4. ALL SOILS EXPOSED DURING LAND DISTURBING ACTIVITY (STRIPPING,
GRADING, UTILITY INSTALLATIONS, STOCKPILING, FILLING, ETC.) SHALL BE
KEPT IN A ROUGHENED CONDITION BY RIPPING OR DISKING ALONG LAND
CONTOURS UNTIL MULCH, VEGETATION, OR OTHER PERMANENT EROSION
CONTROL IS INSTALLED. NO SOILS IN AREAS OUTSIDE PROJECT STREET
RIGHTS OF WAY SHALL REMAIN EXPOSED BY LAND DISTURBING ACTIVITY FOR
MORE THAN THIRTY (30) DAYS BEFORE REQUIRED TEMPORARY OR
PERMANENT EROSION CONTROL (E.G. SEED/MULCH, LANDSCAPING, ETC.) IS
INSTALLED, UNLESS OTHERWISE APPROVED BY THE STORMWATER
DEPARTMENT.
NOTES:
1. OFFSITE GRADING IS LIMITED TO AREAS COVERED BY EXISTING DRAINAGE
AND/OR UTILITY EASEMENTS FOR THE PURPOSE OF UTILITY OR DRAINAGE
CONNECTIONS, UNLESS OTHERWISE NOTED.
2. SEE LANDSCAPE PLAN FOR REVEGETATION METHODS AND DETAILS. DURING
CONSTRUCTION, ANY SOIL DISTURBED AND NOT UNDER ACTIVE
CONSTRUCTION SHALL BE SEEDED AND MULCHED PER LCUASS STANDARDS.
3. CONTRACTOR TO PROVIDE ALL NECESSARY EROSION CONTROL DURING
CONSTRUCTION. PLACE EROSION CONTROL PROTECTION AT ALL EXISTING INLETS
DOWNSTREAM FROM THE CONSTRUCTION AREA. EROSION CONTROL
PROTECTION SHALL REMAIN IN PLACE UNTIL CONSTRUCTION IS COMPLETE AND
ALL DISTURBED GROUND IS ADEQUATELY VEGETATED WITH OWNER'S APPROVAL
FOR REMOVAL.
4. CONTRACTOR TO PROVIDE TEMPORARY BIODEGRADABLE SLOPE STABILIZATION
MAT WHERE SEED CRIMPING IS NOT PRACTICAL. (SHORT TERM): 9.3 POUND
LENO-WOVEN BIODEGRADABLE JUTE TOP NET, 7.7 POUND WOVEN
BIODEGRADABLE JUTE BOTTOM NET, 100% STRAW FIBER MATRIX WITH A
LONGEVITY OF 12 MONTHS. NORTH AMERICAN GREEN S150BN OR ACCEPTED
SUBSTITUTION.
5. THE PROPERTY MUST BE WATERED AND MAINTAINED AT ALL TIMES DURING
CONSTRUCTION ACTIVITIES SO AS TO PREVENT WIND-CAUSED EROSION. ALL
LAND DISTURBING ACTIVITIES SHALL BE IMMEDIATELY DISCONTINUED WHEN
FUGITIVE DUST IMPACTS ADJACENT PROPERTIES, AS DETERMINED BY THE
CITY ENGINEERING DEPARTMENT.
6. ALL TEMPORARY (STRUCTURAL) EROSION CONTROL MEASURES MUST BE
INSPECTED AND REPAIRED OR RECONSTRUCTED AS NECESSARY AFTER EACH
RUNOFF EVENT AND EVERY 14 DAYS IN ORDER TO ASSURE CONTINUED
PERFORMANCE OF THEIR INTENDED FUNCTION. ALL RETAINED SEDIMENTS,
PARTICULARLY THOSE ON PAVED ROADWAY SURFACES, SHALL BE REMOVED
AND DISPOSED OF IN A MANNER AND LOCATION SO AS NOT TO CAUSE THEIR
RELEASE INTO ANY DRAINAGEWAY.
7. NO SOIL STOCKPILE SHALL EXCEED TEN (10) FEET IN HEIGHT. ALL SOIL
STOCKPILES SHALL BE PROTECTED FROM SEDIMENT TRANSPORT BY
SURFACE ROUGHENING, WATERING, AND PERIMETER SILT FENCING. ANY SOIL
STOCKPILE REMAINING AFTER 30 DAYS SHALL BE SEEDED AND MULCHED.
8. CITY ORDINANCE PROHIBITS THE TRACKING, DROPPING, OR DEPOSITING OF
SOILS OR ANY OTHER MATERIAL ONTO CITY STREETS BY OR FROM ANY
VEHICLE. ANY INADVERTENT DEPOSITED MATERIAL SHALL BE CLEANED
IMMEDIATELY BY THE CONTRACTOR.
SEDIMENT CONTROL LOG
EROSION CONTROL BLANKET (AA GREEN C350)
OUTLET STORM PROTECTION
STRUCTURE.
2. LENGTH OF FES ARE INCLUDED IN PIPE LENGTHS.
3. MANHOLE RIM ELEVATIONS ARE APPROXIMATE. CONFIRM FINAL ELEVATIONS PRIOR
TO INSTALLATION.
4. RCP SHALL HAVE FLEXIBLE GASKET MATERIAL (WATER TIGHT RUBBER GASKETS)
CONFORMING TO ASTM C443 AND TPYE 4-G BELL SPIGOT JOINTS.
City Engineer
CHECKED BY:
APPROVED:
Date
Environmental Planner
CALL BEFORE YOU DIG
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
1-800-922-1987
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
NOTES:
1. BURIED UTILITIES AND OR PIPE LINES ARE SHOWN PER VISIBLE SURFACE EVIDENCE
AND AS-BUILT DRAWINGS OF THE CONSTRUCTED UTILITY LINES. THE CONTRACTOR
SHALL VERIFY THE DEPTH AND LOCATION OF ALL EXISTING UTILITY CONNECTIONS
AND CROSSINGS PRIOR TO ANY CONSTRUCTION. IF A CONFLICT OCCURS BETWEEN
EXISTING AND PROPOSED UTILITIES AND/OR DESIGN MODIFICATION IS REQUIRED,
THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE
DESIGN. THE ENGINEER AND/OR THE SURVEYOR OF RECORD SHALL NOT BE LIABLE
FOR THE LOCATION OF OR THE FAILURE TO NOTE THE LOCATION OF NON-VISIBLE
UTILITIES.
2. SITE CONTRACTOR SHALL TERMINATE UTILITY SERVICES 5-FEET FROM BUILDING
UNLESS OTHERWISE NOTED. SITE CONTRACTOR SHALL COORDINATE EXACT
LOCATIONS OF BUILDING UTILITIES WITH ARCHITECTURAL DRAWINGS.
3. ALL STORM SEWER, POWER AND OTHER "DRY" UTILITY INSTALLATIONS, SHALL
CONFORM TO THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS
CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE LOCAL ENGINEER.
4. ALL WATER LINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS -
LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS CURRENT TO THE
DATE OF CONSTRUCTION.
5. ALL SANITARY SEWER LINE CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT
COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS CURRENT TO
THE DATE OF CONSTRUCTION.
6. STORM SEWER PIPE SHALL BE RCP OR HDPE WITH WATER TIGHT JOINTS AS
SPECIFIED ON THE PLAN. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF
FORT COLLINS.
7. LENGTH OF PIPE IS MEASURED FROM CENTER OF STRUCTURE TO CENTER OF
STRUCTURE AND INCLUDES THE FLARED END SECTION.
8. WATER MAINS SHALL BE PVC (C-900) AS SPECIFIED BY THE FORT COLLINS -
LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS.
9. ALL WATER SERVICES SHALL BE INSTALLED AT A MINIMUM OF 5-FEET BELOW
FINISHED FLOOR ELEVATION AND SHALL BE PVC (C-900) UNLESS OTHERWISE
NOTED.
10. ALL SANITARY SEWER PIPE SHALL BE PVC (SDR 35) UNLESS OTHERWISE NOTED ON
THE PLAN. SEWER PIPE SHALL BE AS SPECIFIED BY THE SOUTH FORT COLLINS
SANITATION DISTRICT STANDARDS AND SPECIFICATIONS.
11. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATION DETAILS OF GAS METERS,
ELECTRIC METERS, AND TELEPHONE TERMINALS.
12. LIMITS OF STREET CUT SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY CITY ENGINEER INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
13. CITY OF FORT COLLINS LIGHT & POWER (L&P) SHALL INSTALL PRIMARY LINE FROM
CONNECTION POINT TO ELECTRIC VAULT, SECONDARY LINES FROM VAULT TO
METER, AND BUILDING METER. CONTRACTOR SHALL COORDINATE WITH FORT
COLLINS METER GROUP FOR METER LOCATION. CONTACT CITY OF FORT COLLINS
LIGHT & POWER FOR THEIR CURRENT REQUIREMENTS.
or 8-1-1
CALL 2-BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
NOTES:
1. BURIED UTILITIES AND OR PIPE LINES ARE SHOWN PER VISIBLE SURFACE EVIDENCE
AND AS-BUILT DRAWINGS OF THE CONSTRUCTED UTILITY LINES. THE CONTRACTOR
SHALL VERIFY THE DEPTH AND LOCATION OF ALL EXISTING UTILITY CONNECTIONS
AND CROSSINGS PRIOR TO ANY CONSTRUCTION. IF A CONFLICT OCCURS BETWEEN
EXISTING AND PROPOSED UTILITIES AND/OR DESIGN MODIFICATION IS REQUIRED,
THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE
DESIGN. THE ENGINEER AND/OR THE SURVEYOR OF RECORD SHALL NOT BE LIABLE
FOR THE LOCATION OF OR THE FAILURE TO NOTE THE LOCATION OF NON-VISIBLE
UTILITIES.
2. LIMITS OF STREET CUT SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY CITY ENGINEER INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
3. reference landscape plan & tree mitigation plan for tree removal & protection.
4. Limits of street cut are approximate. Final limits are to be determined in the field b
the city of fort Collins engineering inspector. all repairs to be in accordance with
city street repair standards.
5. CONTRACTOR IS RESPONSIBLE FOR ALL SURFACE REPAIR/REPLACEMENT TO
RESTORE SIDEWALKS, ASPHALT, CURB/GUTTER SECTIONS AND SOD AREAS
DISTURBED BY NEW WORK.
6. EXISTING CONCRETE AND ASPHALT PAVING SHALL BE SAW CUT AND REMOVED
PRIOR TO EXCAVATION. REMOVE CONCRETE SIDEWALKS TO NEAREST JOINT.
7. COORDINATE DEMOLITION REQUIREMENTS, LIMITS OF DEMOLITION, SALVAGE
ITEMS, PROTECTION OF ITEMS TO REMAIN, TREES, FENCING, ETC. WITH OWNER,
ARCHITECT, ENGINEER, AND RELEVANT CONSTRUCTION OR PHASING PLANS.
ADDITIONAL DEMOLITION OF PAVEMENT, TREES, UTILITIES, STRUCTURES, ETC. TO
BE PERFORMED AS REQUIRED.
LEGEND
TREE REMOVAL/RELOCATION
PROTECT EXISTING TREES
AUGUST 2014
UTILITY CONTACTS:
INDEMNIFICATION STATEMENT:
THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR
CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY
THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE
LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE
CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT
QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES
REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON
AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL
ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE
REQUIRED DURING THE CONSTRUCTION PHASE.
CITY OF FORT COLLINS BENCHMARK #38-94
AZIMUTH MARK (3 1/4" ALUMINUM CAP) ON THE NORTH SIDE OF TRILBY RD. 1/2
MILE WEST OF COLLEGE AVE. AT THE SOUTHWEST CORNER OF 508 WEST
TRILBY RD. (GOOD SAMARITAN RETIREMENT CENTER). ALSO 5.5 FT WEST OF A
POWERPOLE AND 24.5 FT SOUTH OF A WOOD FENCE
PROJECT DATUM - ELEV=5090.58 NGVD 29 (UNADJUSTED)
NAVD 88 = NGVD 29 (UNADJUSTED) + 3.18 = 5093.76
CITY OF FORT COLLINS BENCHMARK #47-94
ON THE EAST SIDE OF SOUTH COLLEGE AVE.. AT ROBERT BENSON LAKE, ON
TOP OF THE SOUTHEAST CORNER OF AN INLET.
PROJECT DATUM - ELEV=5019.54 NGVD 29 (UNADJUSTED)
NAVD 88 = NGVD 29 (UNADJUSTED) + 3.18 = 5022.72
BASIS OF BEARINGS
ASSUMING THE NORTH LINE OF THE NORTHEAST QUARTER OF SECTION 14,
715:$6%($5,1*1257+
($67%(,1*$*5,'%($5,1*2)
THE COLORADO STATE PLANE COORDINATE SYSTEM, NORTH ZONE, NORTH
AMERICAN DATUM 1983/2007, A DISTANCE OF 2562.81 FEET WITH ALL OTHER
BEARINGS CONTAINED HEREIN RELATIVE THERETO.
PROPOSED STREET LIGHT
PROPOSED STORM SEWER
EXISTING SANITARY SEWER MAIN
PROPOSED TELEPHONE LINE
EXISTING GAS
EXISTING STORM SEWER
EXISTING WATER MAIN
EXISTING MANHOLE
PROPOSED STORM INLET
LEGEND
PROPOSED CONCRETE
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION
PROPOSED MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
EXISTING UTILITY POLE
EXISTING GUY WIRE
PROPOSED GAS
EXISTING ELECTRIC LINE PROPOSED ELECTRIC LINE
EXISTING TELEPHONE LINE
EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT
EXISTING WATER VALVE
PROPOSED SANITARY SEWER MAIN
PROPOSED WATER MAIN
EXISTING CONCRETE
EXISTING FLOWLINE, CURB & GUTTER PROPOSED FLOWLINE, CURB & GUTTER
PROPOSED FENCE
LIMITS OF CONSTRUCTION
EXISTING OVERHEAD UTILITY
EXISTING STORM SEWER INLET
PROPOSED WATER VALVE
PROPOSED MANHOLE
PROPOSED UTILITY POLE
EXISTING STREET LIGHT
PROPOSED SWALE
PROPOSED DIRECTION OF OVERLAND FLOW
PROPOSED EMERGENCY OVERFLOW ROUTE
EXISTING FIBER OPTIC LINE
PROPOSED HANDICAP RAMP
EXISTING OVERHEAD ELECTRIC LINE
EXISTING OVERHEAD TELEPHONE LINE
PROPOSED OVERHEAD ELECTRIC LINE
PROPOSED FIBER OPTIC LINE
PROPOSED OVERHEAD TELEPHONE LINE
EXISTING FENCE
PROPOSED WATER SERVICE W/
PROPOSED SANITARY SEWER SERVICE
CURB STOP AND METER PIT
W/ CLEANOUT
PROPOSED OVERHEAD UTILITY
PROPOSED LIGHT POLES
vicinity map
Scale: 1" = 1000'
I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE
PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH
ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO
STANDARDS AND STATUTES, RESPECTIVELY, AND THAT I AM FULLY
RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN, REVISIONS AND
RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS.
ROBERT ALMIRALL
P.E. NO. 33441
All changes, addendums, additions, deletions and
modifications to these drawings must be approved,
in writing, by the Fort Collins-Loveland
Water District and the South Fort Collins Sanitation District.
Mr. Terry Farrill, P.E., District Engineer Date
Mr. Michael D. DiTullio, Manager Date
FORT COLLINS - LOVELAND
WATER DISTRICT
SOUTH FORT COLLINS
SANITATION DISTRICT
OWNER / DEVELOPER
HABITAT FOR HUMANITY
4001 S. TAFT HILL ROAD
FORT COLLINS, CO 80525
Ph. 970.223.4522
ENGINEER
Interwest Consulting Group
1218 W. Ash, Suite C
Windsor, Colorado 80550
Ph. 970.674.3300
PLANNER
Vignette Studios
P.O. Box 1889
Fort Collins, Colorado
80522
Ph. 970.472.9125
SURVEYOR
King Surveyors
650 Garden Drive
Windsor, Colorado 80550
Ph. 970.686.5011
FORT COLLINS UTILITIES
700 Wood Street
Fort Collins, Colorado 80522
STORMWATER
Wes Lamarque
Ph. 970.416.2418
LIGHT & POWER
Doug Martine
Ph. 970.221.6700
NATURAL GAS
Xcel Energy
1901 E. Horsetooth Road
Fort Collins, Colorado 80525
Contact: Stephanie Rich
Ph. 970.225.7828
WATER/WASTEWATER
Fort Collins-Loveland Water District
South Fort Collins Sanitation District
5051 Snead Drive
Fort Collins, Colorado 80525
Contact: Terry Farrill
Ph. 970.226.3104
TELEPHONE SERVICE
Century Link (Qwest)
3351 Eastbrook Drive
Fort Collins, Colorado 80525
Contact: Bill Johnson
Ph. 970.377.6401
INDEX OF SHEETS
Sheet No. Description of Sheets
1 COVER SHEET
2 GENERAL NOTES
3 EXISTING & DEMOLITION
4 UTILITY PLAN
5-6 SANITARY SEWER PLAN & PROFILE
7 SANITAY SEWER DETAILS
8 WATERLINE DETAILS
9-10 STORM DRAIN PLAN & PROFILE
11-12 STORM DRAIN DETAILS
13 DRAINAGE & EROSION CONTROL PLAN
14-15 EROSION CONTROL DETAILS
16 SITE & GRADING PLAN
17 SITE & GRADING DETAILS
18 HORIZONTAL CONTROL PLAN
19 SIGNING & STRIPING DETAILS
ABBREVIATION LIST
AD ALGEBRAIC DIFFERENCE
AE ACCESS EASEMENT
ARCH ARCHITECT
ARV AIR RELEASE VALVE
ASPH ASPHALT
BLDG BUILDING
BOV BLOW OFF VALVE
BOS BOTTOM OF STEP
BOW BACK OF WALK
BW BOTTOM OF WALL
CATV CABLE TELEVISION
CL CENTERLINE
CMP CORRUGATED METAL PIPE
CO CLEAN OUT
CoFC CITY OF FORT COLLINS
COMM COMMUNICATION
CONC CONCRETE
COORD COORDINATION
DE DRAINAGE EASEMENT
DEMO DEMOLITION
DIA DIAMETER
E EAST(ING)
EAE EMERGENCY ACCESS
EASEMENT
EG EXISTING GROUND
EL ELEVATION
ELEC ELECTRIC
EOA EDGE OF ASPHALT
EOC EDGE OF CONCRETE
EX EXISTING
ESMT EASEMENT
F FIRE LINE
FES FLARED END SECTION
FF FINISHED FLOOR
FFE FINISHED FLOOR ELEVATION
FG FINISHED GRADE
FH FIRE HYDRANT
FL FLOWLINE
FO FIBER OPTIC
G GAS
GB GRADE BREAK
GF GARAGE FLOOR
GV GATE VALVE
HORZ HORIZONTAL
HDPE HIGH DENSITY POLYETHYLENE
HP HIGH POINT
IE IRRIGATION EASEMENT
INV INVERT
IRR IRRIGATION
LA LANDSCAPE (PLAN/ACRH)
LF LINEAR FEET
LP LOW POINT
LT LEFT
MAX MAXIMUM
ME MATCH EXISTING
MEP MECHANICAL, ELECTRICAL,
PLUMBING ENGINEER
MH MANHOLE
MIN MINIMUM
N NORTH(ING)
NA NOT APPLICABLE
NTS NOT TO SCALE
OC ON CENTER
OHE OVERHEAD ELECTRIC
OHT OVERHEAD TELEPHONE
OHU OVERHEAD UTILITY
PE PEDESTRIAN EASEMENT
PC POINT OF CURVATURE
PCR POINT OF CURB RETURN
PI POINT OF INTERSECTION
PL PROPERTY LINE
PT POINT OF TANGENCY
PVC POLYVINYL CHLORIDE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RE REFERENCE
ROW RIGHT-OF-WAY
RT RIGHT
SS SANITARY SEWER
STA STATION
SD STORM DRAIN PIPE
SDMH STORM DRAIN MANHOLE
SSMH SANITARY SEWER MANHOLE
SWMP STORMWATER MANAGEMENT
PLAN
T TELEPHONE
TB THRUST BLOCK
TBC TOP BACK OF CURB
TBV TO BE VACATED
TC TOP OF CONCRETE
TELE TELEPHONE
TEMP TEMPORARY
TF TOP OF FOUNDATION
TOS TOP OF STEP
TW TOP OF WALL
TYP TYPICAL
UE UTILITY EASEMENT
UGE UNDERGROUND ELECTRIC
UTIL UTILITY
VCP VITRIFIED CLAY PIPE
VERT VERTICAL
VPC VERTICAL POINT OF CURVATURE
VPI VERTICAL POINT OF
INTERSECTION
VPT VERTICAL POINT OF TANGENCY
W WATERLINE
WQCE WATER QUALITY CONTROL
ELEVATION
WSE WATER SURFACE ELEVATION