Loading...
HomeMy WebLinkAboutCAPSTONE COTTAGES - PDP - PDP140004 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSLEMAY AVENUE LINCOLN AVENUE BUCKINGHAM ST. WEBSTER AVE. DUFF DR. N LINK LN. 12TH ST. E VINE DR. LEMAY AVENUE / LINCOLN AVENUE (FOUR-LANE ARTERIAL STREET - 115' R.O.W.) 115' ROW DUFF DRIVE (MINOR COLLECTOR STREET - 76' R.O.W.) 76' ROW 25' {}-50' {}-{} 12' TRAVEL 12' TRAVEL INTERNATIONAL BOULEVARD (TWO-LANE ARTERIAL STREET - 84' R.O.W.) 84' ROW 26' {}-52' {}-{} 9' UTILITY EASEMENT 8' BIKE LN. 19' CENTER MEDIAN 12' TRAVEL 12' TRAVEL 8' BIKE LN. 19' CENTER MEDIAN 15' UTILITY EASEMENT 12' CENTER 12' TRAVEL 15' UTILITY EASEMENT 8' BIKE LN. 12' TRAVEL 8' BIKE LN. 15' UTILITY EASEMENT 11' TRAVEL 6' BIKE LN. 8' PARKING 11' TRAVEL 6' BIKE LN. 8' PARKING 9' UTILITY EASEMENT 25' {}- 15' UTILITY EASEMENT WEBSTER AVENUE (RESIDENTIAL LOCAL STREET - 51' R.O.W.) 51' ROW 15' {}30' {-}-{} 9' UTILITY EASEMENT 15' TRAVEL C001 CONSTRUCTION NOTES GENERAL AND A. Reese A. Boese N/A No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: 4941 4942 4943 12" SS 12" SS 8" SS 12" SS 8" SS 8" SS 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W x x x x x x x UG T 12" W 12" W 12" W 24" W 24" W W Vent Pipe W x x x x x x x x UG UG UG UG UG UG UG UG UG UG UG UG UG UG UG UG T T T T T W H Y D C x x x x 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W D D 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS S 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W S S 10" SS 10" SS 10" SS X X X X X X X X 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W H Y D T T DUFF DRIVE (60' R.O.W.) ���� ������� �������� ������ ���������� ���� ������� �������� ������ ���������� ���� ������� �������� ������ 2�� ���� ������� �������� ������ 3�� ������� ������ ���. EXISTING CONCRETE TO BE REMOVED EXISTING DITCH TO BE REMOVED EXISTING WALL TO BE REMOVED EXISTING TREE TO BE REMOVED (TYP.) EXISTING WOOD POST BARRICADE EXISTING 8" AC ELCO WATER LINE EXISTING FIRE HYDRANT EXISTING 36' -  C102 EXISTING CONDITIONS A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� 4935 4936 4937 4938 4936 4937 4940 4938 4939 OHE OHE OHE OHE OHE OHE S C C SS WV E E E 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W W W W WM W W W W W W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W G G G G G G G G G G G G G G G G 4932 4933 4934 4932 4933 4934 4935 4934 4936 4937 4938 WV 8" W 8Ř W 8Ř W 12" W 12" W 12" W 12" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W H Y D H Y D 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W E E E E E W W W W W W W W W W E E E E E E E E E E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / WEBSTER DRIVE (60' R.O.W.) LINCOLN AVENUE (115' R.O.W.) DUFF DRIVE (60' R.O.W.) ���� ������� �������� ������ ����� ������ ������� ������ ���. ���� ������� �������� ������ ����� ������ ������� ��� ���������� �.�.�. EXISTING 12" AC ELCO WATER LINE EXISTING 8" CITY X X X X X X X X X X X X X X X X X TELE TEL�E TELE �� T T 12" SS 8" SS x x x x x x x x x x x x x x x x x x x x x x x R R R R H B B ��� 4 ������ ������ �� ����� ����� ����������� ������ ������ ��� 4 ������ ������ �� ����� ����� ����������� ������ ������ ��� 3 ������ ������ �� ����� ����� ����������� ������ ������ ������� ��� ���������� �.�.�. ���� ������� �������� ������ ����� ������ ������� 12" SS 8" SS OHE OHE OHE S C C WV E E 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W WM WM W W W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W G G G G G G G E x x x x x x x x x x x x UG UG UG UG UG UG UG T OH OH OH OH OH OH 12" W 12" W 12" W 24" W 24" W W Vent Pipe W x x x x x x x UG UG UG UG UG UG UG UG UG UG UG UG UG UG UG UG T T / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SS SS SS SS TELE � D � SS SS SS SS SS SS SS BLDG 1 BLDG 2 BLDG 3 BLDG 4 BLDG 5 BLDG 6 BLDG 7 BLDG 8 BLDG 9 BLDG 10 BLDG 11 BLDG 12 BLDG 13 BLDG 14 BLDG 15 BLDG 16 BLDG 18 BLDG 19 BLDG 20 BLDG 21 BLDG 22 BLDG 17 BLDG 23 BLDG 24 BLDG 25 BLDG 26 BLDG 18 BLDG 16 BLDG 15 BLDG 18 BLDG 17 BLDG 1 BLDG 2 12" SS 12" SS 8" SS 12" SS 8" SS 8" SS 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W x x x x x x x UG T 12" W 12" W 12" W 24" W 24" W W Vent Pipe W x x x x x x T T BLDG 9 BLDG 8 BLDG 7 BLDG 15 BLDG 9 BLDG 14 BLDG 5 BLDG 13 BLDG 12 BLDG 11 BLDG 4 BLDG 8 BLDG 6 BLDG 10 BLDG 1 BLDG 7 BLDG 3 BLDG 2 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W H Y D S S S S S S S S S S S S S S S S W W W W W W W W W W W W W W W S W W UD UD UD UD UD W 3" PVC WATER 3" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER FIRE HYDRANT FIRE / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W E E E E E E E E E E E E E E D / / / / / / / / / / / / / / / / / / / / / / / / / / / / / E E E E E W W W W W W W W W W E E E E E E E E E E E BLDG 8 BLDG 7 BLDG 4 BLDG 3 BLDG 5 BLDG 2 BLDG 6 BLDG 8 BLDG 7 BLDG 3 BLDG 1 BLDG 6 BLDG 4 BLDG 5 BLDG 9 BLDG 6 BLDG 8 BLDG 5 BLDG 10 BLDG 4 BLDG 7 BLDG 1 BLDG 2 WV 8" W 8Ř W 8Ř W 12" W 12" W 12" W 12" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W H Y D H Y D 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W WEBSTER AVENUE (60' EXISTING ROW) INTERNATIONAL BOULEVARD LINCOLN AVENUE S C C x x x x x x x x x x x x OH OH OH OH OH OH x x x x x x x x x x x R R R R H B B 36" RCP X X X X X X X X X X X X X X X X X D TELE TEL�E TELE D T T D D 36 37 38 35 34 36 37 35 36 35 36 36 4941 4942 4943 24" W x x x x x x x T x x x x x x x x T T T T T C x x x x 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W D D X X X X X X X X X X X X TELE D 45 43 44 43 44 44 41 41 41 41 41 42 43 43 44 42 43 44 41 41 42 43 FUTURE 115' ROW T T 36 37 40 36 37 38 39 41 42 43 39 39 40 39 41 40 41 42 43 38 39 BLDG 14 FFE=40.94 BLDG 11 FFE=40.09 BLDG 12 FFE=40.20 BLDG 13 FFE=40.98 BLDG 1 FFE=44.04 BLDG 2 FFE=43.42 BLDG 3 FFE=42.24 BLDG 4 FFE=42.24 BLDG 5 FFE=41.52 BLDG 6 FFE=40.97 BLDG 7 FFE=40.11 BLDG 10 FFE=38.62 BLDG 7 FFE=37.84 BLDG 8 FFE=37.60 BLDG 9 FFE=37.69 BLDG 9 FFE=39.17 BLDG 8 FFE=39.79 9' UTILITY EASEMENT 15' UTILITY EASEMENT 4935 4936 4937 4938 4936 4937 4940 4938 4939 C C R R R R H B B 36" RCP 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W X X X X X X X X X X X X X X X X X X X D TELE TEL�E D D 42 43 37 40 39 40 40 38 39 39 41 41 41 42 40 39 41 38 4932 4933 4934 4932 4933 4934 4935 4934 4936 4937 4938 X X X X X X X X X X X 36 37 38 35 34 36 37 35 36 35 36 36 35 34 36 38 39 39 39 39 35 34 36 37 38 37 38 39 39 38 38 WEBSTER AVENUE INTERNATIONAL BOULEVARD LINCOLN AVENUE BLDG 10 FFE=38.62 BLDG 6 FFE=39.68 R R HB 36" RCP 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W X X X X X X X X X X X X TELE � W 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 46+00 STA: 37+30.17 L = 1018 . 4 2 ', R = 1 07 5 . 00 ' ∆ = 5 4 . 2 8 D D 10" SS 10" SS 10" SS 6" W S D UD UD UD UD 46+00 47+00 48+00 49+00 50+00 51+00 52+00 53+00 54+00 55+00 STA: 54+76.26 STA: 47+48.59 N37� 27' 48"E 727.67' FUTURE 32' FL-FL FUTURE 32' FL-FL PROPOSED 115' ROW ����� ������ ����� ���������� ���� ������� �������� ������ ���������� REALIGNED LEMAY AVENUE FUTURE DUFF DRIVE (SEE SHEETC505) STA.=50+10.09 (LEMAY AVENUE) STA.=19+47+10 (DUFF DRIVE) FUTURE DUFF DRIVE (SEE SHEETC505) FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK ��� ������ ��� FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT FUTURE 30" VERTICAL CURB & GUTTER FUTURE 30" VERTICAL CURB & GUTTER FUTURE 6' SIDEWALK 4935 4940 4945 4950 4955 4960 4935 4940 56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00 64+00 STA: 61+71.42 N00� 34' 27"E 482.42' L = 695 . 1 5 ' , R = 1 0 7 9 . 7 0 ' ∆ = 36 . 8 9 � N00� 34' 27"E 482.42' ���� ������� ���� ������� �������� ������ ���������� �������� ������ ���������� REALIGNED LEMAY AVENUE F U T UR E 6 ' S I DE W A L K F U T UR 4940 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 4940 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 64+50 65+00 66+00 67+00 4977.18 4977.22 4977.09 4977.22 4977.22 4977.22 4977.22 0.00% PVI STA = 66+43.77 PVI ELEV = 4977.22 EVCS: 65+31.74 EVCE: 4977.22 FUTURE GRADE PROPOSED ELEV. EXISTING ELEV. EXISTING GROUND FUTURE OVERPASS STA.=65+83.32 EL= �4946.83 EXISTING RAILROAD 65+00 66+00 STA: 66+53.83 N00� 34' 27"E 482.42' REALIGNED LEMAY AVENUE FUTURE 6' SIDEWALK FUTURE 32' FL-FL FUTURE 32' FL-FL FUTURE 19' MEDIAN FUTURE 115' ROW x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x DUFF DRIVE 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 STA: 10+00.00 STA: 15+00.00 STA: 17+99.18 FUTURE 50' ��-�� FUTURE 76' ROW S89� 26' 55"E 500.00' L = 2 9 9 . 1 8 ' , R = 6 00 . 0 0 ' ∆ = 2 8 . 57 � LEMAY AVENUE /9TH STREET DUFF DRIVE REALIGNED LEMAY AVENUE (SEE SHEET C502 ) REALIGNED LEMAY AVENUE (SEE SHEET C502 ) 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 STA.=24+60.25 (DUFF DRIVE) STA.=14+29.79 (NORTH CLUB HOUSE DRIVE) 50' ��-�� 76' ROW FUTURE 50' ��-�� FUTURE 76' ROW S60� 52' 44"E 661.07' NORTH CLUB HOUSE DRIVE (SEE SHEET C516 ) STA.=19+47.10 (DUFF DRIVE) STA.=50+10.09 (LEMAY AVENUE) 5' SIDEWALK BUCKINGHAM STREET ���� ������� �������� ������ ���������� FUTURE 30" VERTICAL CURB & GUTTER 9' UTILITY EASEMENT LIMITS OF CONSTRUCTION STA.=24+20.26 TYPE III BARRICADE PROPOSED 30" VERTICAL CURB & GUTTER FUTURE 9' UTILITY EASEMENT EXISTING STORM DRAIN 15' UTILITY EASEMENT 6' SIDEWALK 5' SIDEWALK FUTURE 9' UTILITY EASEMENT FUTURE 5' SIDEWALK 9' UTILITY EASEMENT 4930 4935 4940 4945 4950 4955 4930 4935 4940 4945 T T 27+00 28+00 29+00 30+00 31+00 32+00 STA: 32+53.33 50' ��-�� 76' ROW S60� 52' 44"E 793.08' INTERNATIONAL BOULEVARD (SEE SHEET C508 ) STA.=30+01.99 (DUFF DRIVE) STA.=18+98.29 (INTERNATIONAL BOULEVARD) DUFF DRIVE FUTURE INTERNATIONAL BOULEVARD (SEE SHEET C509 ) ���� ������� �������� ������ 3�� ������� ������ ���. MATCH EXISTING DEMO & RECONSTRUCT EXISTING (HATCH AREA) 60' ROW EXISTING 36' ��-�� 5' SIDEWALK PROPOSED 30" VERTICAL CURB & GUTTER TYPE III BARRICADE FUTURE 9' UTILITY EASEMENT 5' SIDEWALK 9' UTILITY EASEMENT 4930 4935 4940 4945 4950 4955 4930 4935 4940 4945 4950 4955 27+00 28+00 29+00 30+00 31+00 32+00 33+00 4941.37 4940.18 4939.65 4937.15 4941.89 X X X X X X X UD UD UD UD UD UD UD UD UD UD UD UD UD UD ���� ������� �������� ������ ���������� ���� ������� �������� ������ 3�� INTERNATIONAL BOULEVARD DUFF DRIVE (SEE SHEET C507 ) STA.=18+98.29 (INTERNATIONAL BOULEVARD) STA.=30+01.99 (DUFF DRIVE) 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 STA.=10+00.00 (INTERNATIONAL BLVD) STA.=38+61.90 (LINCOLN AVENUE) STA.=13+38.28 (INTERNATIONAL BLVD) STA.=10+00.00 (WEBSTER AVENUE) STA.=15+02.78 (INTERNATIONAL BLVD) STA.=21+77.17 (COTTAGE DRIVE) DUFF DRIVE (SEE SHEET C507 ) 52' ��-�� 84' ROW 84' ROW 52' ��-�� LINCOLN AVENUE (SEE SHEET C511 ) LINCOLN AVENUE 4925 4930 4935 4940 4945 4950 4925 4930 4935 4940 4945 4950 20+00 21+00 22+00 23+00 24+00 25+00 4940.27 4939.69 4939.09 4938.49 4940.35 4940.37 4940.34 4940.14 4939.99 4939.84 4939.54 4939.39 4939.24 4938.94 4938.79 4938.64 4938.34 EXISTING GROUND PROPOSED ELEV. FUTURE GRADE EXISTING ELEV. -0.60% PVI STA = 24+36.44 PVI ELEV = 4938.27 150.0' VC HP ELEV = 4940.37 HP STA = 20+48.29 PVI STA = 20+48.29 PVI ELEV = 4940.60 EVCS: 21+23.29 EVCE: 4940.15 A.D. = 1.20 K = 125.00 ���� ������� �������� ������ ���������� ���� ������� �������� ������ 3�� DUFF DRIVE (SEE SHEET C507 {4935} {4935} 36" RCP D LINCOLN AVENUE 31+00 32+00 33+00 STA.=30+17.52 (LINCOLN AVENUE) STA.=37+30.17 (LEMAY AVENUE) STA: 33+29.50 S89� 29' 09"E 311.98' EXISTING EOA-EOA (WIDTH VARIES) EXISTING EOA-EOA (WIDTH VARIES) EXISTING ROW (WIDTH VARIES) LEMAY AVENUE FUTURE 19' MEDIAN FUTURE 32' ��-�� REALIGNED LEMAY AVENUE (SEE SHEET C501 ) EXISTING EOA-EOA (WIDTH VARIES) ������� ��� ���������� �.�.�. ��� 3 ������ ������ �� ����� ����� ����������� ������ ������ �������� ���������� ������ ���� �� �������� 40' UTILITY EASEMENT 4930 4935 4940 4945 4950 4955 4930 4935 4940 4945 4950 4955 29+50 30+00 31+00 32+00 33+00 33+50 4941.74 D D UD UD UD LINCOLN AVENUE INTERNATIONAL BOULEVARD (SEE SHEET C508 ) STA.=38+61.90 (LINCOLN AVENUE) STA.=10+00.00 (INTERNATIONAL BOULEVARD) 33+00 34+00 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 STA: 33+29.50 STA: 39+03.12 L = 573 .62 ' , R=1 1 48.50' ∆ = 2 8. 6 2� 115' ROW EXISTING EOP-EOP (WIDTH VARIES) FUTURE 32'��-�� FUTURE 32' ��-�� EXISTING 115' ROW FUTURE 32' ��-�� FUTURE 32' ��-�� EXISTING EOP-EOP (WIDTH VARIES) FUTURE 19' 43+00 44+00 45+00 46+00 47+00 48+00 49+00 50+00 51+00 52+00 STA: 52+01.27 S60� 52' 09"E 1298.14' FUTURE 32' ��-�� FUTURE 32' ��-�� FUTURE 19' MEDIAN EXISTING EOP-EOP (WIDTH VARIES) LINCOLN AVENUE ������� ��� ���������� �.�.�. ���� ������� �������� ������ ����� ��� �������� & ����� ��������� 2�� FUTURE 115' ROW 12TH STREET FUTURE 6' SIDEWALK EXISTING EDGE OF ASPHALT EXISTING CURB & GUTTER FUTURE 30" VERTICAL CURB & GUTTER FUTURE 30" VERTICAL CURB & GUTTER FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK 4925 4930 4935 4940 4945 4950 4925 4930 4935 4940 4945 4950 43+00 44+00 45+00 46+00 47+00 48+00 49+00 50+00 51+00 52+00 52+50 4935.88 4935.28 4934.68 W W UD UD UD UD UD UD UD UD UD UD UD UD ���� ������� �������� ������ ����� ������ INTERNATIONAL BOULEVARD (SEE SHEET C508 ) STA.=10+00.00 (WEBSTER AVENUE) STA.=13+38+28 (INTERNATIONAL BOULEVARD) ���� ������� �������� ������ ����� ������ 11+00 12+00 13+00 14+00 15+00 STA: 15+44.78 S60� 52' 44"E 544.78' 30' ��-�� 20' ��-�� 51' ROW EXISTING 60' ROW WEBSTER AVENUE 30" VERTICAL CURB & GUTTER MATCH EXISTING EXISTING �30' FL-FL 4925 4930 4935 4940 4945 4950 4925 4930 4935 4940 4945 4950 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 4938.92 4938.36 4937.88 4937.40 24" W 24" W 24" W 24" W CLUB HOUSE REALIGNED LEMAY AVENUE (SEE SHEET C501 ) NORTH CLUB HOUSE DRIVE (SEE SHEET C516) COTTAGE DRIVE REALIGNED LEMAY AVENUE (SEE SHEET C501 ) 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 STA: 10+00.00 STA: 16+59.00 (COTTAGE DRIVE) STA.=10+00.00 (NORTH CLUB HOUSE DRIVE) STA: 10+38.63 STA: 12+91.98 STA: 17+33.91 STA: 10+99.60 STA: 13+93.51 STA: 18+08.05 S68� 18' 09"E 192.38' S76� 36' 47"E 265.49' S76� 36' 47"E 74.91' S60� 52' 44"E 216.06' L = 6 0 . 9 7 ', R = 1 6 5. 0 UD UD UD UD UD UD UD UD UD UD INTERNATIONAL BOULEVARD (SEE SHEET C508 ) STA.=21+77.17 (COTTAGE DRIVE) STA.=15+02.78 (INTERNATIONAL BOULEVARD) COTTAGE DRIVE 19+00 20+00 21+00 STA: 20+24.11 S60� 52' 44"E 216.06' S60� 52' 44"E 153.05' INTERNATIONAL BOULEVARD (SEE SHEET C508 ) 32' FL-FL 44' FL-FL 83' AE, EAE, UE & DE 36' ��-�� 30" VERTICAL CURB & GUTTER 30" VERTICAL CURB & GUTTER 4.5' SIDEWALK 4.5' SIDEWALK 4930 4935 4940 4945 4950 4955 4930 4935 4940 4945 4950 4955 19+00 20+00 21+00 22+00 22+50 4938.63 4938.96 4939.28 4939.06 4938.83 4938.56 4938.62 ���� ������� �������� ������ ���������� CLUB HOUSE DUFF DRIVE (SEE SHEETC506) FUTURE 5' SIDEWALK STA.=14+29.79 (NORTH CLUB HOUSE DRIVE) STA.=24+60.25 (DUFF DRIVE) COTTAGE DRIVE (SEE SHEET C514) NORTH CLUB HOUSE DRIVE STA.=10+00.00 (NORTH CLUB HOUSE DRIVE) STA.=16+59.00 (COTTAGE DRIVE) 73' AE, EAE, UE & DE 34' FL-FL 22' FL-FL 30' FL-FL 73' AE, EAE, UE & DE COTTAGE DRIVE (SEE SHEET C514) FUTURE DUFF DRIVE (SEE SHEETC506) 11+00 12+00 13+00 14+00 STA: 10+87.80 STA: 11+33.11 N13� 23' 13"E 87.80' N29� 07' 16"E 296.68' L = 4 5 . 3 1 ' , R = 1 6 5 . 12" SS 8" SS C C x x x x x x x x x x x x T x x x x x x x T T T T T C x x x x R R R R H B B 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W D D 10" SS 10" SS 10" SS S 6" W 6" W 6" W 6" W 6" W S S X X X X X X X X X X X X X X X X X D TELE TEL�E TELE D T T D D 4935 4932 4933 4934 4936 4937 4938 4932 4933 4934 4935 4934 4936 4937 4940 4937 4938 4939 4941 4942 4943 ����� ������ ����� ���������� ��� 4 ������ ������ �� ����� ����� ����������� ������ ������ ��� 4 ������ ������ �� ����� ����� ����������� ������ ������ ��� 3 ������ ������ �� ����� ����� ����������� ������ ������ ������� ��� ���������� �.�.�. ���� ������� �������� ������ ����� ������ ������� ������ ���. ���� ������� �������� ������ 3�� ���� ������� �������� ���� ������� �������� ������ ���������� ���� ������� �������� ������ ���������� ���� ������� �������� ������ ���������� UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD 36 37 38 35 34 36 37 35 36 35 36 36 35 34 36 37 40 45 36 37 38 39 41 42 43 44 42 43 44 44 38 39 39 39 39 39 35 34 36 37 38 37 38 40 39 40 40 38 39 39 41 41 41 41 42 40 39 39 41 38 40 41 42 41 42 42 43 40 39 41 42 43 40 41 42 43 44 38 39 42 43 44 41 41 42 43 41 42 43 43 43 45 43 44 L I N C O L N A V E N U E R E A L I G N E D L E M A Y A V E N U E WEBSTER AVENUE DUFF DRIVE MAINT. TRASH INTERNATIONAL BOULEVARD CLUB HOUSE SOUTH CLUB HOUSE DRIVE COTTAGE DRIVE NORTH CLUB HOUSE DRIVE 1 3.88 4 2.27 2 3.22 3 3.59 7 2.54 6 5.19 5 4.11 OS1 0.58 1 OS1 4 5 6 7 8 8 0.89 2 3 C600 DRAINAGE EXHIBIT A. Reese A. Boese 1"=80' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 80 0 80 Feet 80 160 240 LEGEND: 4953 PROPOSED CONTOUR PROPOSED STORM DRAIN PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET DESIGN POINT 1 FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROJECT BENCHMARKS NOTES: 1. REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT FOR CAPSTONE COTTAGES" BY NORTHERN ENGINEERING, DATED MAY 7, 2014FOR ADDITIONAL INFORMATION. BASIN DESIGNATION BASIN AREA (AC) FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION PROPOSED UNDERDRAIN UD PERMEABLE PAVERS X.XXX 1 BENCHMARK #1: City of Fort Collins Benchmark 3-00 NGVD29 Elevation= 4964.15 (NAVD88 Elevation= 4967.33) BENCHMARK #2: City of Fort Collins Benchmark 12-07 NGVD29 Elevation= 4944.68 (NAVD88 Elevation= 4947.86) C��� E������� D��� D��� D��� D��� D��� S��������� U������ P���� & R��������� T������ E������� D��� APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: W���� U������ C��� �� F��� C������, C������� UTILITY PLAN APPROVAL E������������ P������ 00 ' ∆ = 1 5 . 7 3 � 30" VERTICAL CURB & GUTTER 30" VERTICAL CURB & GUTTER 4930 4935 4940 4945 4950 4955 4930 4935 4940 4945 4950 4955 9+50 10+00 11+00 12+00 13+00 14+00 15+00 4941.93 4942.30 4942.68 4943.31 4943.58 4943.86 4944.41 4944.65 4944.72 4944.34 4943.96 4943.59 4943.64 PROPOSED GRADE PROPOSED ELEV. EXISTING ELEV. EXISTING GROUND -2.25% 1.50% 1.10% -1.10% -1.50% 2.25% PVI STA = 10+00.00 PVI ELEV = 4942.17 PVI STA = 10+14.00 PVI ELEV = 4941.86 PVI STA = 10+17.00 PVI ELEV = 4941.69 PVI STA = 10+20.00 PVI ELEV = 4941.86 PVI STA = 10+95.00 PVI ELEV = 4942.98 PVI STA = 13+23.79 PVI ELEV = 4944.36 PVI STA = 13+98.79 PVI ELEV = 4943.23 PVI STA = 14+02.79 PVI ELEV = 4943.06 PVI STA = 14+06.79 PVI ELEV = 4943.23 PVI STA = 14+29.79 PVI ELEV = 4943.75 75.0' VC HP ELEV = 4944.72 HP STA = 12+71.93 PVI STA = 12+71.93 PVI ELEV = 4944.93 BVCS: 12+34.43 BVCE: 4944.51 EVCS: 13+09.43 EVCE: 4944.51 A.D. = 2.20 K = 34.09 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C516 PLAN & PROFILE NORTH CLUB HOUSE DRIVE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE NORTH CLUB HOUSE DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) C516 4938.78 4939.13 4939.31 4939.82 -0.90% 0.70% 2.25% PVI STA = 21+53.17 PVI ELEV = 4939.33 PVI STA = 21+77.17 PVI ELEV = 4939.87 75' VC LP ELEV = 4938.56 LP STA = 20+26.60 PVI STA = 20+21.91 PVI ELEV = 4938.41 BCVS: 19+84.41 BVCE: 4938.75 ECVS: 20+59.41 EVCE: 4938.67 A.D. = 1.60 K = 46.87 PROPOSED GRADE PROPOSED ELEV. EXISTING ELEV. EXISTING GROUND STA.=20+35.11 INV.= 4933.03 UNDERDRAIN No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C515 PLAN & PROFILE COTTAGE DRIVE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE COTTAGE DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C514 STA 19+00 LINE MATCH STA 19+00 C514 C515 0 ' ∆ = 2 1 . 1 7 � L = 101 . 53 ' , R = 700 . 0 0 ' ∆ = 8 . 3 1 � L = 7 4 . 14 ' , R = 2 7 0 . 0 0 ' ∆ = 1 5 . 7 3 � 44' FL-FL 65' FL-FL 32' FL-FL 44' FL-FL 83' AE, EAE, UE & DE 44' ��-�� 65' ��-�� S89� 28' 32"E 38.63' 30' INTERIM ACCESS DRIVE 83' AE, EAE, UE & DE LEMAY AVENUE 30" VERTICAL CURB & GUTTER 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4930 4935 4940 4945 4950 4955 4930 4935 4940 4945 4950 4955 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 4941.16 4940.39 4940.81 4941.36 4941.91 4941.97 4940.68 4941.83 4941.61 4941.38 4940.93 4940.71 4940.50 4940.41 4940.53 4940.67 4940.94 4941.08 4941.22 4941.49 4941.63 4941.77 4942.04 4942.16 4942.14 4941.66 4941.33 4941.01 4940.36 4940.03 4939.73 -0.90% -0.90% -0.90% 0.55% -1.30% PVI STA = 11+00.33 PVI ELEV = 4942.05 PVI STA = 11+50.33 PVI ELEV = 4941.60 PVI STA = 18+69.36 PVI ELEV = 4939.78 75' VC HP ELEV = 4942.17 HP STA = 16+59.25 PVI STA = 16+74.45 PVI ELEV = 4942.32 BVCS: 16+36.95 BVCE: 4942.11 EVCS: 17+11.95 EVCE: 4941.83 A.D. = 1.85 K = 40.54 75' VC LP ELEV = 4940.38 LP STA = 13+09.05 PVI STA = 13+00.00 PVI ELEV = 4940.26 BCVS: 12+62.50 BVCE: 4940.59 ECVS: 13+37.50 EVCE: 4940.46 A.D. = 1.45 K = 51.72 PROPOSED GRADE EXISTING GROUND PROPOSED ELEV. EXISTING ELEV. STA.=12+84.60 INV.= 4935.46 EXISTING 36" RCP STA.=13+09.05 INV.= 4935.58 UNDERDRAIN No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C514 PLAN & PROFILE COTTAGE DRIVE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE COTTAGE DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C515 STA 19+00 LINE MATCH STA 19+00 C514 C515 4936.89 4936.39 4935.88 4935.38 4934.88 4934.38 4933.97 4933.63 4933.37 4933.19 -2.25% -0.50% -1.93% -2.02% PVI STA = 10+00.00 PVI ELEV = 4938.92 PVI STA = 10+24.00 PVI ELEV = 4938.38 PVI STA = 13+42.42 PVI ELEV = 4933.10 MATCH EXISTING PVI STA = 10+74.00 PVI ELEV = 4937.42 120.0' VC PVI STA = 12+70.16 PVI ELEV = 4933.46 BCVS: 12+10.16 BVCE: 4934.67 ECVS: 13+30.16 EVCE: 4933.16 A.D. = 1.52 K = 79.06 PROPOSED GRADE PROPOSED ELEV. EXISTING ELEV. EXISTING GROUND (-0.56%) STA.=11+41.16 INV.= 4932.11 UNDERDRAIN No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C513 PLAN & PROFILE WEBSTER AVENUE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE WEBSTER AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) C513 4934.08 4933.57 4933.07 4932.57 4932.07 4931.57 4936.33 4936.18 4936.03 4935.73 4935.58 4935.43 4935.13 4934.98 4934.83 4934.53 4934.38 4934.23 4933.95 4933.82 4933.70 4933.45 4933.32 4933.20 4932.95 4932.82 4932.70 4932.45 4932.32 4932.20 4931.95 4931.82 4931.70 -0.60% -0.50% PVI STA = 47+04.35 PVI ELEV = 4934.05 PVI STA = 52+01.27 PVI ELEV = 4931.57 FUTURE GRADE EXISTING GROUND PROPOSED ELEV. EXISTING ELEV. No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C512 PLAN & PROFILE LINCOLN AVENUE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE LINCOLN AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C511 STA 43+00 LINE MATCH STA 43+00 C510 C511 C512 MEDIAN FUTURE 19' MEDIAN ������� ��� ���������� �.�.�. ���� ������� �������� ������ ����� ������ EXISTING R.O.W. TO BE VACATED 40' UTILITY EASEMENT 40' UTILITY EASEMENT 40' UTILITY EASEMENT 6' SIDEWALK 6 ' S I D E W A L K SOUTH CLUB HOUSE DRIVE 6' SIDEWALK 4930 4935 4940 4945 4950 4955 4930 4935 4940 4945 4950 4955 33+50 34+00 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 4941.67 4941.51 4940.78 4940.08 4939.48 4938.88 4938.28 4937.68 4937.08 4941.59 4941.70 4941.69 4941.62 4941.34 4941.16 4940.97 4940.59 4940.41 4940.23 4939.93 4939.78 4939.63 4939.33 4939.18 4939.03 4938.73 4938.58 4938.43 4938.13 4937.98 4937.83 4937.53 4937.38 4937.23 4936.93 4936.78 4936.63 0.50% -0.60% -0.75% -0.60% PVI STA = 36+67.25 PVI ELEV = 4940.28 PVI STA = 38+61.90 PVI ELEV = 4939.11 160.0' VC HP ELEV = 4941.70 HP STA = 34+28.98 PVI STA = 34+44.98 PVI ELEV = 4941.94 BVCS: 33+64.98 BVCE: 4941.54 EVCS: 35+24.98 EVCE: 4941.34 A.D. = 1.25 K = 128.00 FUTURE GRADE EXISTING GROUND PROPOSED ELEV. EXISTING ELEV. No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C511 PLAN & PROFILE LINCOLN AVENUE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE LINCOLN AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C510 STA 33+50 MATCH LINE SEE SHEET C512 STA 43+00 LINE MATCH STA 33+50 LINE MATCH STA 43+00 C510 C511 EXISTING C512 CURB & GUTTER 4941.26 4941.24 4942.11 4941.99 4941.86 4941.61 4941.49 4941.36 4941.19 4941.17 4941.18 4941.34 -0.50% 0.50% PVI STA = 30+17.52 PVI ELEV = 4942.15 150.0' VC LP ELEV = 4941.17 LP STA = 32+51.96 PVI STA = 32+51.96 PVI ELEV = 4940.98 BCVS: 31+76.96 BVCE: 4941.35 ECVS: 33+26.96 EVCE: 4941.35 A.D. = 1.00 K = 150.00 FUTURE GRADE EXISTING GROUND PROPOSED ELEV. EXISTING ELEV. No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C510 PLAN & PROFILE LINCOLN AVENUE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE LINCOLN AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C511 STA 33+50 LINE MATCH STA 33+50 C510 C511 C512 ) 19+00 20+00 21+00 22+00 23+00 24+00 STA: 24+36.44 DUFF DRIVE (SEE SHEET C507 ) N28� 43' 57"E 538.15' FUTURE 84' ROW FUTURE 52'  -  INTERNATIONAL BOULEVARD STA.=18+98.29 (INTERNATIONAL BOULEVARD) STA.=30+01.99 (DUFF DRIVE) FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK LIMITS OF CONSTRUCTION TYPE III BARRICADE FUTURE 9' UTILITY EASEMENT FUTURE 9' UTILITY EASEMENT FUTURE 30" VERTICAL CURB & GUTTER No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C509 PLAN & PROFILE INTERNATIONAL BOULEVARD A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE INTERNATIONAL BLVD SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C508 STA 20+00 LINE MATCH STA 20+00 C508 C509 (SEE SHEET C511 ) WEBSTER AVENUE (SEE SHEETC513) COTTAGE DRIVE (SEE SHEETC515) N28� 43' 57"E 338.28' N28� 43' 57"E 164.50' N28� 43' 57"E 395.51' LIMITS OF CONSTRUCTION TYPE III BARRICADE 15' UTILITY EASEMENT 15' UTILITY EASEMENT PROPOSED 30" VERTICAL CURB & GUTTER 6' SIDEWALK 6' SIDEWALK 4925 4930 4935 4940 4945 4950 4925 4930 4935 4940 4945 4950 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 4937.79 4937.79 4938.58 4939.48 4939.87 4939.39 4938.85 4939.15 4939.71 4938.12 4937.92 4937.70 4937.67 4937.70 4937.93 4938.13 4938.35 4938.80 4939.03 4939.25 4939.66 4939.78 4939.85 4939.83 4939.74 4939.59 4939.18 4939.02 4938.91 4938.85 4938.91 4939.02 4939.27 4939.41 4939.56 4939.86 4940.01 4940.16 PROPOSED GRADE EXISTING ELEV. PROPOSED ELEV. EXISTING GROUND STA.=17+11.98 INV.= 4934.08 18" RCP STA.=11+49.58 INV.= 4931.63 24" RCP STA.=10+44.74 INV.= 4931.08 48" RCP -0.90% -0.85% 0.60% 0.90% 0.90% 0.90% 0.50% 0.60% 0.60% PVI STA = 10+39.52 PVI ELEV = 4938.22 PVI STA = 13+20.67 PVI ELEV = 4938.76 PVI STA = 13+38.28 PVI ELEV = 4938.92 PVI STA = 18+38.29 PVI ELEV = 4939.34 PVI STA = 18+98.29 PVI ELEV = 4939.70 PVI STA = 19+48.29 PVI ELEV = 4940.00 200.0' VC HP ELEV = 4939.87 HP STA = 14+95.13 PVI STA = 14+92.28 PVI ELEV = 4940.31 BVCS: 13+92.28 BVCE: 4939.41 EVCS: 15+92.28 EVCE: 4939.46 A.D. = 1.75 K = 114.29 BVCS: 19+73.29 BVCE: 4940.15 200.0' VC LP ELEV = 4937.67 LP STA = 11+49.58 PVI STA = 11+49.58 PVI ELEV = 4937.22 BCVS: 10+49.58 BVCE: 4938.12 ECVS: 12+49.58 EVCE: 4938.12 A.D. = 1.80 K = 111.11 150.0' VC LP ELEV = 4938.84 LP STA = 17+11.84 PVI STA = 16+92.40 PVI ELEV = 4938.61 BCVS: 16+17.40 BVCE: 4939.25 ECVS: 17+67.40 EVCE: 4938.98 A.D. = 1.35 K = 111.11 LIMITS OF CONSTRUCTION No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C508 PLAN & PROFILE INTERNATIONAL BOULEVARD A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE INTERNATIONAL BLVD SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C509 STA 20+00 LINE MATCH STA 20+00 C508 C509 4941.72 4941.54 4941.13 4940.86 4940.55 4939.80 4939.43 4939.06 4939.18 4938.44 4937.74 4936.66 4936.28 4935.99 -0.80% -2.25% -3.00% -1.50% -0.70% -1.10% PVI STA = 31+90.97 PVI ELEV = 4935.86 PVI STA = 30+25.99 PVI ELEV = 4939.16 PVI STA = 29+77.99 PVI ELEV = 4939.16 PVI STA = 29+72.99 PVI ELEV = 4938.99 PVI STA = 29+67.99 PVI ELEV = 4939.16 PVI STA = 28+08.84 PVI ELEV = 4941.31 PVI STA = 28+67.99 PVI ELEV = 4940.66 135' VC PVI STA = 31+15.97 PVI ELEV = 4936.46 BCVS: 30+48.47 BVCE: 4938.48 ECVS: 31+83.47 EVCE: 4935.92 A.D. = 2.20 K = 61.36 PROPOSED GRADE PROPOSED ELEV. EXISTING ELEV. EXISTING GROUND No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C507 PLAN & PROFILE DUFF DRIVE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE DUFF DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C506 STA 27+00 LINE MATCH STA 27+00 C506 C505 C507 4950 4955 18+50 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 4942.90 4943.08 4944.56 4945.34 4944.87 4944.17 4943.47 4942.77 4943.30 4943.35 4943.80 4943.26 4943.45 4943.83 4944.20 4944.83 4945.09 4945.26 4945.33 4945.22 4945.04 4944.69 4944.52 4944.34 4943.99 4943.82 4943.64 4943.29 4943.12 4942.94 4942.59 4942.42 4942.24 PROPOSED GRADE EXISTING GROUND EXISTING ELEV. PROPOSED ELEV. -1.50% 2.31% -2.14% -0.70% 1.50% 1.10% -0.70% -0.70% PVI STA = 18+99.11 PVI ELEV = 4942.94 PVI STA = 19+03.15 PVI ELEV = 4942.77 PVI STA = 19+07.20 PVI ELEV = 4942.94 PVI STA = 19+47.10 PVI ELEV = 4943.86 PVI STA = 19+87.04 PVI ELEV = 4943.00 PVI STA = 19+91.09 PVI ELEV = 4942.84 PVI STA = 19+95.13 PVI ELEV = 4943.00 PVI STA = 20+95.13 PVI ELEV = 4944.50 PVI STA = 24+20.26 PVI ELEV = 4944.03 PVI STA = 24+60.25 PVI ELEV = 4943.75 120' VC HP ELEV = 4945.35 HP STA = 22+08.46 PVI STA = 21+95.13 PVI ELEV = 4945.60 BVCS: 21+35.13 BVCE: 4944.94 EVCS: 22+55.13 EVCE: 4945.18 A.D. = 1.80 K = 66.67 FUTURE GRADE LIMITS OF CONSTRUCTION No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C506 PLAN & PROFILE DUFF DRIVE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE DUFF DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C505 STA 18+50 MATCH LINE SEE SHEET C507 STA 27+00 LINE MATCH STA 27+00 LINE MATCH STA 18+50 NORTH C506 C505 C507 FUTURE 5' SIDEWALK FUTURE 5' SIDEWALK EXISTING EOP-EOP BUCKINGHAM STREET (WIDTH VARIES) EXISTING 67' ROW FUTURE 9' UTILITY EASEMENT FUTURE 9' UTILITY EASEMENT EXISTING 112' ROW BUCKINGHAM STREET ALLEY 10TH STREET ����� ������ ����� ���������� ����� ����� 2�� ������ 2 ��� ������� ������� 3�� �������� ����� EXISTING EOA-EOA (WIDTH VARIES) FUTURE 30" VERTICAL CURB & GUTTER FUTURE 30" VERTICAL CURB & GUTTER 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 18+50 4943.61 4943.31 4943.70 4944.32 4945.13 4944.43 4943.74 4943.49 4943.38 4943.32 4943.35 4943.45 4943.57 4943.90 4943.99 4944.00 4944.65 4944.92 4945.08 4945.09 4944.94 4944.70 4944.05 2.00% -2.00% -1.10% -1.50% 1.30% 1.00% -0.50% 0.50% PVI STA = 12+67.91 PVI ELEV = 4943.77 PVI STA = 15+39.62 PVI ELEV = 4944.20 PVI STA = 15+59.62 PVI ELEV = 4943.80 PVI STA = 18+00.22 PVI ELEV = 4944.42 PVI STA = 16+34.62 PVI ELEV = 4944.77 PVI STA = 15+19.62 PVI ELEV = 4943.80 130' VC HP ELEV = 4945.13 HP STA = 17+01.71 PVI STA = 17+04.80 PVI ELEV = 4945.47 BVCS: 16+39.80 BVCE: 4944.82 EVCS: 17+69.80 EVCE: 4944.76 A.D. = 2.10 K = 61.90 120' VC LP ELEV = 4943.31 LP STA = 13+91.63 PVI STA = 13+91.63 PVI ELEV = 4943.16 BCVS: 13+31.63 BVCE: 4943.46 ECVS: 14+51.63 EVCE: 4943.46 A.D. = 1.00 K = 120.00 FUTURE GRADE PROPOSED ELEV. EXISTING ELEV. EXISTING GROUND No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C505 PLAN & PROFILE DUFF DRIVE A. Reese A. Boese 1"=40' KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE DUFF DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C506 STA 18+50 LINE MATCH STA 18+50 C506 C505 C507 FUTURE 50' ��-�� FUTURE 76' ROW ���� ������� �������� ������ ���������� ��� ������ ��� 2�� VINE DRIVE EXISTING ROW FUTURE 6' SIDEWALK EXISTING 80' ROW BURLINGTON NORTHERN RAILROAD STA.=65+83.32 FUTURE 30" VERTICAL CURB & GUTTER FUTURE 30" VERTICAL CURB & GUTTER No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C504 PLAN & PROFILE LEMAY AVENUE A. Reese A. Boese 1"=40' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE LEMAY AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 64+50 C501 KEYMAP C503 C504 C502 MATCH LINE SEE SHEET C503 STA 64+50 E 6 ' S I DE W A L K FUTURE 32' FL-FL FUTURE 32' FL-FL FUTURE 19' MEDIAN FUTURE 115' ROW ��� ������ ��� EXISTING ROW (WIDTH VARIES) EXISTING ROW (WIDTH VARIES) F U T U R E 1 5 ' U T I L I TY EAS E M E N T F U T UR E 1 5 ' U T I L I T Y EA SE M E N T FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK EXISTING ROW EXISTING ROW FUTURE 30" VERTICAL CURB & GUTTER FUTURE 30" VERTICAL CURB & GUTTER 4935 4940 4945 4950 4955 4960 4965 4970 4975 4980 4985 4935 4940 4945 4950 4955 4960 4965 4970 4975 4980 4985 55+50 56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00 64+00 64+50 4949.18 4952.10 4955.92 4960.63 4965.44 4969.45 4972.63 4974.98 4976.50 4948.60 4949.83 4950.53 4951.28 4952.97 4953.90 4954.88 4957.02 4958.17 4959.38 4961.88 4963.12 4964.31 4966.52 4967.55 4968.53 4970.33 4971.15 4971.92 4973.30 4973.91 4974.47 4975.44 4975.84 4976.20 4976.75 5.00% 600.0' VC PVI STA = 62+31.74 PVI ELEV = 4977.22 BVCS: 59+31.74 BVCE: 4962.22 A.D. = 5.00 K = 120.00 490.0' VC PVI STA = 56+34.65 PVI ELEV = 4947.37 ECVS: 58+79.65 EVCE: 4959.62 A.D. = 4.45 K = 110.11 FUTURE GRADE EXISTING ELEV. PROPOSED ELEV. EXISTING GROUND FUTURE GRADE No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C503 PLAN & PROFILE LEMAY AVENUE A. Reese A. Boese 1"=40' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE LEMAY AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 64+50 LINE MATCH STA 55+50 C501 KEYMAP C503 C504 C502 MATCH LINE SEE SHEET C502 STA 55+50 MATCH LINE SEE SHEET C504 STA 64+50 4945 4950 4955 4960 46+00 47+00 48+00 49+00 50+00 51+00 52+00 53+00 54+00 55+00 55+50 4943.20 4942.82 4943.20 4943.80 4944.40 4944.98 4945.53 4946.08 4947.18 4943.61 4943.50 4943.35 4943.05 4942.92 4942.85 4942.85 4942.92 4943.05 4943.35 4943.50 4943.65 4943.95 4944.10 4944.25 4944.55 4944.70 4944.84 4945.11 4945.25 4945.39 4945.66 4945.80 4945.94 4946.27 4946.52 4946.82 4947.59 -0.60% 0.60% 0.60% 0.55% PVI STA = 50+09.68 PVI ELEV = 4943.86 PVI STA = 51+50.00 PVI ELEV = 4944.70 EVCS: 46+52.95 EVCE: 4943.48 150.0' VC LP ELEV = 4942.82 LP STA = 48+00.00 PVI STA = 48+00.00 PVI ELEV = 4942.60 BCVS: 47+25 BVCE: 4943.05 ECVS: 48+75 EVCE: 4943.05 A.D. = 1.20 K = 125.00 BCVS: 53+89.65 BVCE: 4946.02 FUTURE GRADE EXISTING GROUND EXISTING ELEV. PROPOSED ELEV. No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C502 PLAN & PROFILE LEMAY AVENUE A. Reese A. Boese 1"=40' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE LEMAY AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C501 STA 46+00 MATCH LINE SEE SHEET C503 STA 55+00 LINE MATCH STA 55+50 LINE MATCH STA 46+00 C501 KEYMAP C503 C504 C502 EXISTING 100' ROW FUTURE 115' ROW � FUTURE 32' FL-FL FUTURE 32' FL-FL FUTURE 115' ROW EXISTING EOP-EOP (WIDTH VARIES) ��� 3 ������ ������ �� ����� ����� ����������� ������ ������ REALIGNED LEMAY AVENUE LINCOLN AVENUE COTTAGE DRIVE (SEE SHEETC514 ) 30' INTERIM ACCESS DRIVE F U T U R E 6' SID E W A L K ���� �� �������� E X I S T I N G 6 ' S I D E W A L K SIGHT DISTANCE EASEMENT 15 ' U T I L I T Y E AS E M E N T EXISTING 57.5' 1/2 ROW FUTURE 30" VERTICAL CURB & GUTTER FUTURE 30" VERTICAL CURB & GUTTER 4930 4935 4940 4945 4950 4955 4930 4935 4940 4945 4950 4955 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 46+00 4940.48 4940.88 4941.01 4940.64 4940.37 4940.99 4942.22 4943.34 4940.28 4940.38 4940.58 4940.68 4940.78 4940.96 4941.01 4941.03 4940.96 4940.88 4940.77 4940.50 4940.40 4940.36 4940.44 4940.57 4940.75 4941.28 4941.59 4941.90 4942.53 4942.84 4943.12 4943.51 4943.62 4943.68 FUTURE GRADE (BY BANK OF COLORADO) EXISTING GROUND 0.40% 1.25% -0.41% -0.55% PVI STA = 37+30.17 PVI ELEV = 4940.20 PVI STA = 40+75.28 PVI ELEV = 4940.77 150.0' VC HP ELEV = 4941.03 HP STA = 39+74.71 PVI STA = 39+75.38 PVI ELEV = 4941.18 BVCS: 39+00.38 BVCE: 4940.88 EVCS: 40+50.38 EVCE: 4940.87 A.D. = 0.81 K = 186.00 205.0' VC HP ELEV = 4943.68 HP STA = 45+86.46 PVI STA = 45+50.45 PVI ELEV = 4944.10 BVCS: 44+47.95 BVCE: 4942.82 A.D. = 1.85 K = 110.81 200.0' VC LP ELEV = 4940.36 LP STA = 41+81.72 PVI STA = 42+20.61 PVI ELEV = 4939.97 BCVS: 41+20.61 BVCE: 4940.52 ECVS: 43+20.61 EVCE: 4941.22 A.D. = 1.80 K = 111.11 PROPOSED ELEV. EXISTING ELEV. FUTURE GRADE No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C501 PLAN & PROFILE LEMAY AVENUE A. Reese A. Boese 1"=40' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM DRAIN EXISTING STORM DRAIN EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPOSED STORM INLET PROJECT BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE LEMAY AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C502 STA 46+00 LINE MATCH STA 46+00 C501 KEYMAP C503 C504 C502 BLDG 7 FFE=38.66 BLDG 9 FFE=36.96 BLDG 4 FFE=39.15 BLDG 5 FFE=39.20 BLDG 3 FFE=34.58 BLDG 4 FFE=35.51 BLDG 5 FFE=35.70 BLDG 6 FFE=36.11 BLDG 7 FFE=36.50 BLDG 8 FFE=36.90 BLDG 1 FFE=35.95 BLDG 2 FFE=34.95 BLDG 1 FFE=37.14 BLDG 2 FFE=36.58 BLDG 3 FFE=36.69 BLDG 4 FFE=36.90 BLDG 5 FFE=37.24 BLDG 6 FFE=38.18 BLDG 7 FFE=37.84 BLDG 8 FFE=37.60 9' UTILITY EASEMENT 9' UTILITY EASEMENT UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD COTTAGE DRIVE ���� ������� �������� ������ ����� ������ ������� ������ ���. 15' UTILITY EASEMENT 15' UTILITY EASEMENT INTERIM ASPHALT ACCESS ROAD MATCH EXISTING WEBSTER AVENUE 4934 4935 4936 4935 4934 4933 4934 4935 4936 4935 DUFF DRIVE 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK EXISTING EOP-EOP (WIDTH VARIES) PROPOSED UNDERDRAIN (TYP.) PROPOSED STORM DRAIN PROPOSED UNDERDRAIN PROPOSED UNDERDRAIN PROPOSED STORM DRAIN BLDG 8 FFE=38.00 PAVER DETENTION AREA C404 GRADING PLAN A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C402 MATCHLINE-SEE SHEET C403 LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR PROJECT BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: 2.0% PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED CURB & GUTTER PROPOSED STORM DRAIN EXISTING STORM DRAIN PROPOSED UNDERDRAIN UD C401 C402 C403 C404 40 41 42 41 42 42 43 41 42 43 COMPACTOR BLDG 18 FFE=42.39 BLDG 16 FFE=42.35 BLDG 8 FFE=38.00 BLDG 9 FFE=36.96 BLDG 10 FFE=37.57 BLDG 11 FFE=38.52 BLDG 12 FFE=39.57 BLDG 13 FFE=39.58 BLDG 14 FFE=38.85 BLDG 15 FFE=40.19 BLDG 26 FFE=41.09 BLDG 1 FFE=40.67 BLDG 2 FFE=38.87 BLDG 5 FFE=39.20 BLDG 3 FFE=40.84 CLUB HOUSE BLDG 27 FFE=43.11 BLDG 25 FFE=40.26 BLDG 24 FFE=40.37 BLDG 23 FFE=41.35 BLDG 22 FFE=40.91 BLDG 21 FFE=40.64 BLDG 18 FFE=41.50 BLDG 17 FFE=41.14 BLDG 16 FFE=40.28 15' UTILITY EASEMENT BLDG 15 FFE=41.80 BLDG 19 (MAINT.) FFE=40.67 POOL DECK FFE=42.11 UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD COTTAGE DRIVE ������ ������ �� ����� ����� ����������� ������� ��� ���������� �.�.�. LINCOLN AVENUE INTERIM ASPHALT ACCESS ROAD INTERIM ASPHALT ACCESS ROAD 4939 4938 4937 4936 4935 4935 4936 4935 6' SIDEWALK LEMAY AVENUE ���� �� �������� 6' SIDEWALK EXISTING EOP-EOP (WIDTH VARIES) PROPOSED STORM DRAIN BLDG 20 FFE=40.60 SOUTH CLUB HOUSE DRIVE PROPOSED EXISTING 36" RCP UNDERDRAIN STORM DRAIN EXISTING 36" RCP STORM DRAIN EXISTING 42" RCP STORM DRAIN PAVER DETENTION AREA PROPOSED UNDERDRAIN PAVER DETENTION AREA PROPOSED UNDERDRAIN BLDG 14 FFE=40.94 BLDG 4 FFE=39.15 C403 GRADING PLAN A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C401 MATCHLINE-SEE SHEET C404 LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR PROJECT BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: 2.0% PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED CURB & GUTTER PROPOSED STORM DRAIN EXISTING STORM DRAIN PROPOSED UNDERDRAIN UD C401 C402 C403 C404 15' UTILITY EASEMENT INTERNATIONAL BOULEVARD DUFF DRIVE BLDG 15 FFE=41.80 UD UD UD UD UD ���� ������� �������� ������ 3�� ���� ������� �������� ������ 2�� ���� ������� �������� ������ ���������� ���� ������� �������� ������ ���������� PORTION OF EXISTING DUFF DRIVE TO BE REMOVED AND RECONSTRUCTED MATCH EXISTING DUFF DRIVE 4939 4938 4937 4936 4935 4934 4935 4936 4938 6' SIDEWALK 5' SIDEWALK 6' SIDEWALK PROPOSED STORM DRAIN EXISTING �36' FL-FL PROPOSED UNDERDRAIN PAVER DETENTION AREA BLDG 14 FFE=40.94 C402 GRADING PLAN A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C404 MATCHLINE-SEE SHEET C401 LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR PROJECT BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: 2.0% PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED CURB & GUTTER PROPOSED STORM DRAIN EXISTING STORM DRAIN PROPOSED UNDERDRAIN UD C401 C402 C403 C404 41 42 43 43 43 45 43 44 BLDG 14 FFE=41.13 BLDG 13 FFE=42.05 BLDG 12 FFE=42.38 BLDG 11 FFE=42.92 BLDG 10 FFE=44.28 BLDG 9 FFE=43.92 BLDG 8 FFE=43.46 BLDG 7 FFE=43.44 BLDG 6 FFE=43.14 BLDG 5 FFE=43.11 BLDG 4 FFE=42.71 BLDG 3 FFE=42.64 BLDG 2 FFE=42.28 BLDG 26 FFE=41.43 BLDG 25 FFE=40.98 BLDG 24 FFE=40.94 BLDG 23 FFE=40.78 BLDG 22 FFE=41.27 BLDG 21 FFE=40.89 BLDG 20 FFE=41.17 BLDG 17 FFE=40.88 BLDG 16 FFE=40.73 BLDG 19 FFE=41.68 BLDG 18 FFE=42.39 BLDG 16 FFE=42.35 BLDG 1 FFE=44.04 BLDG 2 FFE=43.42 BLDG 18 FFE=41.50 BLDG 18 FFE=42.74 BLDG 17 FFE=42.85 15' UTILITY EASEMENT BLDG 1 FFE=42.26 BLDG 15 FFE=40.61 BLDG 15 FFE=41.80 UD UD UD UD COTTAGE DRIVE NORTH CLUB HOUSE DRIVE ����� ������ ����� ���������� ���� ������� �������� ������ ���������� INTERIM ASPHALT ACCESS ROAD LIMITS OF CONSTRUCTION BUCKINGHAM STREET ALLEY 10TH STREET FUTURE REALIGNED LEMAY AVENUE EXISTING 100' ROW 76' ROW DUFF DRIVE 115' ROW TRACT A LEMAY AVENUE 5' SIDEWALK 6' SIDEWALK 4942 4941 4940 4940 4939 4939 4938 9' UTILITY EASEMENT PROPOSED STORM DRAIN EXISTING 36' EOA-EOA 15' UTILITY EASEMENT EXISTING STORM DRAIN PROPOSED EXISTING 36" RCP UNDERDRAIN STORM DRAIN PAVER DETENTION AREA PROPOSED UNDERDRAIN (TYP.) C401 GRADING PLAN A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C403 MATCHLINE-SEE SHEET C402 LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR PROJECT BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: 2.0% PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED CURB & GUTTER PROPOSED STORM DRAIN EXISTING STORM DRAIN PROPOSED UNDERDRAIN UD C401 C402 C403 C404 FUTURE 115' ROW 35 34 36 37 40 45 36 37 38 39 41 42 43 44 42 43 44 44 38 39 39 39 39 39 35 34 36 37 38 37 38 40 39 40 40 38 39 39 41 41 41 41 42 40 39 39 41 38 40 41 42 41 42 42 43 40 39 41 42 43 40 41 42 43 44 38 39 42 43 44 41 41 42 43 41 42 43 43 43 45 43 44 4935 4932 4933 4934 4936 4937 4938 4932 4933 4934 4935 4934 4936 4937 4940 4937 4938 4939 4941 4942 4943 WEBSTER AVENUE DUFF DRIVE MAINT. TRASH INTERNATIONAL BOULEVARD CLUB HOUSE ����� ������ ����� ���������� ��� 4 ������ ������ �� ����� ����� ����������� ������ ������ ��� 4 ������ ������ �� ����� ����� ����������� ������ ������ ��� 3 ������ ������ �� ����� ����� ����������� ������ ������ ������� ��� ���������� �.�.�. ���� ������� �������� ������ ����� ������ ������� ������ ���. ���� ������� �������� ������ 3�� ���� ������� �������� ������ 2�� ���� ������� �������� ������ ���������� ���� ������� �������� ������ ���������� ���� ������� �������� ������ ���������� LINCOLN AVENUE FUTURE LEMAY AVENUE FUTURE DUFF DRIVE FUTURE LEMAY AVENUE INTERIM ASPHALT ACCESS ROAD INTERIM ASPHALT ACCESS ROAD INTERIM ASPHALT ACCESS ROAD FUTURE INTERNATIONAL BOULEVARD FUTURE STREET BUCKINGHAM STREET ALLEY 10TH STREET DUFF DRIVE ���� �� �������� UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD SOUTH CLUB HOUSE DRIVE COTTAGE DRIVE NORTH CLUB HOUSE DRIVE ���� ������� �������� ������ ����� ������ C400 GRADING PLAN OVERALL A. Reese A. Boese 1"=80' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 80 0 80 Feet 80 160 240 KEYMAP R R R R R RC401 R C402 C403 C404 FOR REFERENCE ONLY. SEE 40 SCALE DRAWINGS FOR DETAILED INFORMATION. LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR PROJECT BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: 2.0% PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED CURB & GUTTER PROPOSED STORM DRAIN EXISTING STORM DRAIN PROPOSED UNDERDRAIN UD C��� E������� D��� D��� D��� D��� D��� S��������� U������ P���� & R��������� T������ E������� D��� APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: W���� U������ C��� �� F��� C������, C������� UTILITY PLAN APPROVAL E������������ P������ S S S S S S S S S S S S S S S S S S S S S S S W W W W W W W W W W W W W W W W W W W W W W W W UD UD UD UD UD UD UD UD S W UD UD UD UD UD UD UD UD UD UD UD UD UD W W 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 3" PVC WATER 3" PVC WATER 3" PVC WATER 3" PVC WATER 3" PVC WATER 6" PVC WATER 6" PVC WATER 12" PVC WATER 12" PVC WATER 8" PVC SEWER 12" PVC WATER 8" PVC WATER FIRE HYDRANT FIRE HYDRANT FIRE HYDRANT 52' ��-�� 84' ROW FUTURE 19' MEDIAN EXISTING 115' ROW FUTURE 32' ��-�� FUTURE 32' ��-�� EXISTING EOP-EOP (WIDTH VARIES) 30' ��-�� 20' ��-�� 51' ROW 20' ��-�� SANITARY SERVICE (TYP.) WATER SERVICE (TYP.) 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 30' AE, EAE, UE & DE 30' AE, EAE, UE & DE 32' ��-�� 44' ��-�� 36' ��-�� CONNECT TO EXISTING 12" AC WATERLINE (ELCO) MASTER METER MASTER METER MASTER METER 83' AE, EAE, UE & DE 3" PVC WATER MASTER METER COTTAGE DRIVE WEBSTER AVENUE STORM DRAIN (TYP.) EXISTING 12" AC WATERLINE (ELCO) 40' UTILITY EASEMENT EXISTING 6" PVC WATERLINE (ELCO) CONNECT TO EXISTING 6" ELCO WATERLINE EXISTING 8" PVC WATERLINE (CITY OF FORT COLLINS) EXISTING 24" RCCP NWCWD WATERLINE 12" PVC WATER 6' UTILTY EASEMENT 6' UTILTY EASEMENT 20' UTILITY EASEMENT 120' AE, UE & DE 41' AE, UE & DE 99' AE, UE & DE 41' AE, UE & DE DUFF DRIVE (60' EXISTING ROW) ���� ������� �������� ������ ����� ������ ������� ������ ���. FIRE HYDRANT 20' UTILITY EASEMENT BLDG 8 BLDG 5 BLDG 4 ±30' FL-FL EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT BLDG 2 BLDG 1 BLDG 1 BLDG 2 UNDERDRAIN STORM DRAIN 15' UTILITY EASEMENT 15' UTILITY EASEMENT C304 UTILITY PLAN A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C302 MATCHLINE-SEE SHEET C303 EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM DRAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER ELCO WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL SEWER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W G T E EXISTING STORM DRAIN EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS S W PROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED CURB STOP & METER PIT FDC PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROJECT BOUNDARY ABBREVIATIONS: AE = ACCESS EASEMENT DE = DRAINAGE EASEMENT UE = UTILITY EASEMENT EAE = EMERGENCY ACCESS EASEMENT PROPOSED UNDERDRAIN UD C301 C302 C303 C304 � TELE TEL�E � �� D D BLDG 18 BLDG 20 BLDG 23 BLDG 18 BLDG 22 BLDG 27 BLDG 24 BLDG 25 BLDG 1 BLDG 21 BLDG 16 BLDG 14 BLDG 12 BLDG 9 BLDG 16 BLDG 3 BLDG 11 BLDG 15 BLDG 15 BLDG 8 BLDG 13 BLDG 2 BLDG 14 BLDG 26 BLDG 19 BLDG 5 BLDG 17 BLDG 4 BLDG 10 OHE OHE OHE OHE OHE OHE S C C SS WV E E E 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W W W W WM W W W W W W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W G G G G G G G G G G G G G G G G G E E R R R R H B B 24" W OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP WV WV WV WV WV WV WV WV TS TS EV EV E E E E E E E E E H Y D H Y D WV WD D D D D W W T DD D T T E T G T T T T T T TT G G G G G GG W W W W W W W W W W W 36" RCP 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W W W W 12" W 12" W L I N C O L N A V E N U E R E A L I G N E D L E M A Y A V E N U E MAINT. TRASH CLUB HOUSE S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S W W W W W W W W W W W W W W W W W W W W W W W W W W W S W W W W UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD S W EXISTING 12" PVC SANITARY SEWER (CITY OF FORT COLLINS) 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 3" PVC WATER 3 " P V C W A T E R 3 " P V C W A T E R 3" PVC WATER 3" PVC WATER 12" PVC WATER 12" PVC WATER 12" PVC WATER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER FIRE HYDRANT FIRE HYDRANT 73' AE, EAE, UE & DE 34' ��-�� 3" PVC WATER 3" PVC WATER 3 " P V C W A T E R 8" PVC SEWER 30' AE, 24' AE, EAE & UE EAE & UE 24' AE, EAE & UE 24' AE, EAE & UE 44' ��-�� 83' AE, EAE, UE & DE FUTURE 32' ��-�� FUTURE 32' ��-�� FUTURE 115' ROW EXISTING 40.7' EOP-EOP FUTURE 19' MEDIAN EXISTING 115' ROW EXISTING EOP-EOP (WIDTH VARIES) FUTURE 32' ��-�� FUTURE 32' ��-�� SIGHT DISTANCE EASEMENT 30' AE, EAE, UE & DE 30' AE, EAE, UE & DE 30' AE, EAE & UE WATER SERVICE (TYP.) SANITARY SERVICE (TYP.) 30' AE, EAE, UE & DE 30' AE, EAE, UE & DE 32' ��-�� 44' ��-�� MASTER METER 83' AE, EAE, UE & DE COTTAGE DRIVE UNDERDRAIN F U T U R E 6 ' S I D E W A L K EXISTING 24" D.I.P. WATERLINE (CITY OF FORT COLLINS) EXISTING 24" RCCP WATERLINE (NWCWD) 12" AC WATERLINE (ELCO) TO BE ABANDONED IN PLACE EXISTING 20' UTILITY EASEMENT EXISTING 10' UTILITY & DRAINAGE EASEMENT EXISTING 8" D.I.P. WATERLINE (CITY OF FORT COLLINS) EXISTING 24" RCCP WATERLINE (NWCWD) 12" AC WATERLINE (ELCO) TO BE ABANDONED IN PLACE EXISTING 36" RCP STORM DRAIN ���� �� �������� (�� ������ �� ���� �����) 10' MOUNTAIN STATES TELEPHONE AND TELEGRAPH COMPANY RIGHT-OF-WAY EASEMENT 30' UTILITY EASEMENT 40' UTILITY EASEMENT CONNECT TO EXISTING 12" AC WATERLINE (ELCO) UNDER DRAIN 20' UTILITY EASEMENT ������ ������ �� ����� ����� ����������� ������� ��� ���������� �.�.�. 6" PVC WATER 6" PVC WATER FIRE HYDRANT CONNECT TO EXISTING 12" SANITARY WITH NEW MANHOLE CONNECT TO EXISTING STORM DRAIN TIE TO EXISTING 48" STORM DRAIN SOUTH CLUB HOUSE DRIVE 15' DRAINAGE EASEMENT BLDG 14 BLDG 8 BLDG 5 C303 UTILITY PLAN A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C301 MATCHLINE-SEE SHEET C304 EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM DRAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER ELCO WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL SEWER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W G T E EXISTING STORM DRAIN EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS S W PROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED CURB STOP & METER PIT FDC PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROJECT BOUNDARY ABBREVIATIONS: AE = ACCESS EASEMENT DE = DRAINAGE EASEMENT UE = UTILITY EASEMENT EAE = EMERGENCY ACCESS EASEMENT PROPOSED UNDERDRAIN UD C301 C302 C303 C304 HYDRANT 50' FL-FL 76' ROW 84' ROW 52' - FUTURE 9' UTILITY EASEMENT WATER SERVICE (TYP.) SANITARY SERVICE (TYP.) 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 24' AE, EAE, UE & DE 32' FL-FL 44' FL-FL INTERNATIONAL BOULEVARD DUFF DRIVE MASTER METER 83' AE, EAE, UE & DE COTTAGE DRIVE STORM DRAIN (TYP.) DUFF DRIVE (60' EXISTING ROW) 36' - EXISTING 8" PVC ELCO WATERLINE CONNECT TO EXISTING 8" ELCO WATERLINE 24' AE, EAE, UE & DE 24' AE, EAE, UE & DE 24' AE, EAE, UE & DE 20' UTILITY EASEMENT ���� ������� �������� ������ 3�� ���� ������� �������� ������ 2�� ���� ������� �������� ������ ���������� ���� ������� �������� ������ ���������� 15' DRAINAGE EASEMENT BLDG 2 9' UTILITY EASEMENT BLDG 14 STUB AND CAP 8" PVC WATERLINE EXISTING FIRE HYDRANT 15' UTILITY EASEMENT 15' UTILITY EASEMENT C302 UTILITY PLAN A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C304 MATCHLINE-SEE SHEET C301 EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM DRAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER ELCO WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL SEWER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W G T E EXISTING STORM DRAIN EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS S W PROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED CURB STOP & METER PIT FDC PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROJECT BOUNDARY ABBREVIATIONS: AE = ACCESS EASEMENT DE = DRAINAGE EASEMENT UE = UTILITY EASEMENT EAE = EMERGENCY ACCESS EASEMENT PROPOSED UNDERDRAIN UD C301 C302 C303 C304 x x UG UG UG UG UG UG UG UG UG UG UG UG UG UG UG UG T T T T T W H Y D C x x x x 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W D D SS SS SS SS SS SS SS S 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W S S R E A L I G N E D L E M A Y A V E N U E DUFF DRIVE EXISTING 10" SANITARY SEWER S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W S W W W W UD UD UD UD 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 3" PVC WATER 3" PVC WATER 6" PVC WATER 12" PVC WATER 12" PVC WATER 1 2 " P V C W A T E R 8" PVC SEWER 8" PVC WATER 8" PVC SEWER 8" PVC SEWER FIRE HYDRANT FIRE HYDRANT FIRE HYDRANT 44' - 1 5 ' U T I L I T Y E A S E M E N T 73' AE, EAE, UE & DE 34' FL-FL 22' FL-FL 24' AE, EAE, UE & DE 24' AE, EAE, UE & DE 24' AE, EAE, UE & DE FUTURE 32' FL-FL FUTURE 32' FL-FL 115' ROW 30' FL-FL 6' PAN (TYP.) FUTURE 50' FL-FL 76' ROW 30' INTERIM ACCESS DRIVE SIGHT DISTANCE EASEMENT WATER SERVICE (TYP.) SANITARY SERVICE (TYP.) 24' AE, EAE, UE & DE 3" PVC WATER CONNECT TO EXISTING 12" AC ELCO WATERLINE MASTER METER MASTER METER 8" PVC WATER 83' AE, EAE, UE & DE 73' AE, EAE, UE & DE COTTAGE DRIVE NORTH CLUB HOUSE DRIVE UNDERDRAIN BUCKINGHAM STREET BUCKINGHAM STREET ALLEY 10TH STREET EXISTING ROW (WIDTH VARIES) FUTURE 115' ROW FUTURE 76' ROW 1 5 ' U T I L I T Y E A S E M E N T F U T U R E 6 ' S I D E W A L K EXISTING 24" D.I.P. WATERLINE (CITY OF FORT COLLINS) EXISTING 24" RCCP WATERLINE (NWCWD) EXISTING 12" AC WATERLINE (ELCO) 12" AC WATERLINE (ELCO) TO BE ABANDONED IN PLACE EXISTING 10" SANITARY SEWER (CITY OF FORT COLLINS) EXISTING 20' UTILITY EASEMENT EXISTING 10' UTILITY & DRAINAGE EASEMENT EXISTING 36" STORM DRAIN FUTURE 5' SIDEWALK ����� ������ ����� ���������� ���� ������� �������� ������ ���������� EXISTING 100' ROW F U T U R E 6 ' S I D E W A L K UNDERDRAIN CONNECT TO EXISTING STORM DRAIN CONNECT TO EXISTING 10" SANITARY WITH NEW MANHOLE EXISTING STORM DRAIN 9' UTILITY EASEMENT BLDG 2 C301 UTILITY PLAN A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� KEYMAP R R R R R R R CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C303 MATCHLINE-SEE SHEET C302 EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM DRAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER ELCO WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL SEWER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W G T E EXISTING STORM DRAIN EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS S W PROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED CURB STOP & METER PIT FDC PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROJECT BOUNDARY ABBREVIATIONS: AE = ACCESS EASEMENT DE = DRAINAGE EASEMENT UE = UTILITY EASEMENT EAE = EMERGENCY ACCESS EASEMENT PROPOSED UNDERDRAIN UD C301 C302 C303 C304 T T T W H YD C x x x x R R R R H B B OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP WV WV WV WV WV WV WV WV TS TS EV EV E E E E E E E E E H Y D H Y D WV WD D D D D W W T DD D T T E E E T G T T T T T T TT G G G G G GGW W W W W W W W W W W 36" RCP 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W W W W 12" W 12" W 6" W 6" W 6" W 6" W 6" W 8" W 8" W 8" W 8" W 8" W H Y D H Y D 8" W 8" W 8" W 12" W 12" W 12" W 24" W 24" W D D SS SS SS S 6" W 6" W 6" W 6" W 6" W S S SS SS SS SS SS SS SS SS X X X X X X X X X X X X X X X X X E E 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W E E E E E E E E E E E D � TELE TEL�E � TELE � D �� T T D � SS SS SS D L I N C O L N A V E N U E R E A L I G N E D L E M A Y A V E N U E ��� 4 ������ ������ �� ����� ����� ����������� ������ ������ ��� 4 ������ ������ �� ����� ����� ����������� ������ ������ ��� 3 ������ ������ �� ����� ����� ����������� ������ ������ ������� ��� ���������� �.�.�. ���� ������� �������� ������ ����� ������ ������� ������ ���. ���� ������� �������� ������ 3�� ���� ������� �������� ������ ���������� ���� ������� �������� ������ ���������� ���� ������� �������� ������ 2�� ���� ������� ����� ������ �������� ������ ���������� ����� ���������� W W W W W W UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD 12" PVC WATER 1 2 " P V C W A T E R 8" PVC WATER 8" PVC WATER 12" PVC WATER 6" PVC WATER 3 " P V C W A T E R 12" PVC WATER 12" PVC WATER 12" PVC WATER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 8" PVC SEWER 3" PVC WATER 3" PVC WATER 3" PVC WATER 3" PVC WATER 6" PVC WATER 3" PVC WATER 3" PVC WATER 3 " P V C W A T E R 3" PVC WATER 3" PVC WATER 8" PVC SEWER 8" PVC SEWER WEBSTER AVENUE DUFF DRIVE MAINT. TRASH INTERNATIONAL BOULEVARD CLUB HOUSE COTTAGE DRIVE NORTH CLUB HOUSE DRIVE 8" PVC WATER 3" PVC WATER STORM DRAIN 3" PVC WATER CONNECT TO EXISTING 6" WATERLINE (ELCO) EXISTING 6" PVC WATERLINE (ELCO) EXISTING 8" PVC WATERLINE (ELCO) CONNECT TO EXISTING 8" WATERLINE (ELCO) EXISTING 12" PVC SANITARY SEWER (CITY OF FORT COLLINS) EXISTING 8" WATERLINE (CITY OF FORT COLLINS) CONNECT TO EXISTING 12" AC WATERLINE (ELCO) CONNECT TO EXISTING 12" AC WATERLINE (ELCO) ���� �� �������� 12" WATERLINE (ELCO) TO BE ABANDONED IN PLACE EXISTING 24" RCCP WATERLINE (NWCWD) EXISTING 8" PVC WATERLINE (CITY OF FORT COLLINS) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 6" PVC WATER 8" PVC SEWER SOUTH CLUB HOUSE DRIVE STORM DRAIN STORM DRAIN STORM DRAIN 3" PVC WATER 12" WATERLINE (ELCO) TO BE ABANDONED IN PLACE C300 UTILITY PLAN OVERALL A. Reese A. Boese 1"=80' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 80 0 80 Feet 80 160 240 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R RC301 R C302 C303 C304 EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM DRAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER ELCO WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL SEWER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W G T E EXISTING STORM DRAIN EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS S W PROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED CURB STOP & METER PIT FDC PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROJECT BOUNDARY PROPOSED UNDERDRAIN UD FOR REFERENCE ONLY. SEE 40 SCALE DRAWINGS FOR DETAILED INFORMATION. ������ ���. ���� ������� �������� ������ 3�� ���� ������� �������� ������ ���������� ���� ������� �������� ������ ���������� ���� ������� �������� ������ 2�� ���� ������� �������� ������ ���������� ����� ������ ����� ���������� ���� �� �������� WEBSTER AVENUE DUFF DRIVE MAINT. TRASH INTERNATIONAL BOULEVARD CLUB HOUSE LINCOLN AVENUE LEMAY AVENUE INTERIM ASPHALT PAVING INTERIM ASPHALT PAVING INTERIM ASPHALT PAVING COTTAGE DRIVE NORTH CLUB HOUSE DRIVE SOUTH CLUB HOUSE DRIVE BUCKINGHAM STREET ALLEY 10TH STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO K��� ����'� �����. C��� ������ ��� ���. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C200 PAVING PLAN A. Reese B. Ruch 1"=80' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� NOTES: 1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2.PAVEMENT MARKINGS SHALL BE PER CITY STANDARDS AND PROJECT SPECIFICATION MANUAL. 3.SEE GEOTECHNICAL REPORT FOR SUBGRADE PREPARATION AND PAVEMENT RECOMMENDATIONS. 4.REFER TO SITE AND LANDSCAPE PLANS FOR PAVERS, DECORATIVE PAVING, SCORING, ETC. 5.REFER TO ARCHITECTURAL PLANS FOR PRIVATE SIGNAGE AND STRIPING INFORMATION. 6.CONCRETE PARKING LOT SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 330R-08. NORTH ( IN FEET ) 1 inch = ft. 80 0 80 Feet 80 160 240 EXISTING RIGHT OF WAY LEGEND: PROPOSED CURB & GUTTER EASEMENT LINE PROJECT BOUNDARY PROPOSED RIGHT-OF-WAY PUBLIC PAVING PRIVATE PAVING PERMEABLE PAVERS OF FORT COLLINS WATER LINE EXISTING 24" NWCWD WATER LINE EXISTING WETLAND EXISTING 6" AC ELCO WATER LINE EXISTING WETLAND EXISTING FIRE HYDRANT EXISTING 30' -  EXISTING FIRE HYDRANT EXISTING 12" AC ELCO WATER LINE TO BE ABANDONED IN PLACE EXISTING 52' - EOP EXISTING 36" VERTICAL CURB AND GUTTER EXISTING EDGE OF ASPHALT C104 EXISTING CONDITIONS A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� EXISTING ELECTRIC E LEGEND: G T EXISTING STORM DRAIN EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES TO BE REMOVED NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. REFER TO LANDSCAPE PLANS FOR TREE REMOVAL AND MITIGATION. 7. REFER TO ENVIRONMENTAL CHARACTERIZATION STUDY DATED SEPTEMBER 3, 2013 BY CEDAR CREEK ASSOCIATES FOR ADDITIONAL INFORMATION. EXISTING SANITARY SEWER EXISTING WATER EXISTING FENCE EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 EXISTING MONITORING WELL MW VAULT ELEC H Y CONTROL IRR H2O G EXISTING LOT LINE Northern Engineering Services, Inc. Project No. 939-001 Date: July 31, 2013 ORIGINAL FIELD SURVEY BY: 8" SS 8" W EXISTING TREES TO REMAIN EXISTING WETLANDS X CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C102 MATCHLINE-SEE SHEET C103 C101 C102 C103 C104 G E E R R R R H B B 24" W OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP WV WV WV WV WV WV WV WV TS TS EV EV E E E E E E E E E H Y D H Y D WV WD D D D D W W T DD D T T E T G T T T T T T TT G G G G G GG W W W W W W W W W W W 36" RCP 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W W W W 12" W 12" W 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS X X X X X X X X X X X X X X X X X X X X X X X X X X W W W W W W W W W W W W W W E E E E E E E E E E E E E E D � TELE TEL�E � �� D D EXISTING 20' UTILITY EASEMENT (BK. 1691 PG. 057) EXISTING 10' UTILITY AND DRAINAGE EASEMENT (REC. #97070197) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / LEMAY AVENUE (PUBLIC R.O.W. WIDTH VARYS) LINCOLN AVENUE (115' R.O.W.) ������� ��� ���������� �.�.�. ���� �� �������� EXISTING 36" RCP EXISTING 48" RCP STORM DRAIN EXISTING 48" RCP STORM DRAIN EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING CONCRETE TO BE REMOVED EXISTING TREES TO BE REMOVED (TYP.) EXISTING TREES TO BE REMOVED (TYP.) 12" AC ELCO WATER LINE TO BE ABANDONED IN PLACE EXISTING 24" NWCWD WATER LINE EXISTING 24" NWCWD WATER LINE EXISTING 8" D.I.P. CITY OF FORT COLLINS WATER LINE EXISTING 12" AC ELCO WATER LINE TO BE ABANDONED IN PLACE EXISTING 24" D.I.P. CITY OF FORT COLLINS WATERLINE 5' DIA. FILLED STONE WELL EXISTING WETLAND EXISTING 10" PVC SANITARY (CITY OF FORT COLLINS) EXISTING 12" AC ELCO WATER LINE TO BE ABANDONED IN PLACE EXISTING EDGE OF ASPHALT EXISTING 30" VERTICAL CURB AND GUTTER C103 EXISTING CONDITIONS A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� EXISTING ELECTRIC E LEGEND: G T EXISTING STORM DRAIN EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES TO BE REMOVED NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. REFER TO LANDSCAPE PLANS FOR TREE REMOVAL AND MITIGATION. 7. REFER TO ENVIRONMENTAL CHARACTERIZATION STUDY DATED SEPTEMBER 3, 2013 BY CEDAR CREEK ASSOCIATES FOR ADDITIONAL INFORMATION. EXISTING SANITARY SEWER EXISTING WATER EXISTING FENCE EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 EXISTING MONITORING WELL MW VAULT ELEC H Y CONTROL IRR H2O G EXISTING LOT LINE Northern Engineering Services, Inc. Project No. 939-001 Date: July 31, 2013 ORIGINAL FIELD SURVEY BY: 8" SS 8" W EXISTING TREES TO REMAIN EXISTING WETLANDS X CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C101 MATCHLINE-SEE SHEET C104 C101 C102 C103 C104 E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� EXISTING ELECTRIC E LEGEND: G T EXISTING STORM DRAIN EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES TO BE REMOVED NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. REFER TO LANDSCAPE PLANS FOR TREE REMOVAL AND MITIGATION. 7. REFER TO ENVIRONMENTAL CHARACTERIZATION STUDY DATED SEPTEMBER 3, 2013 BY CEDAR CREEK ASSOCIATES FOR ADDITIONAL INFORMATION. EXISTING SANITARY SEWER EXISTING WATER EXISTING FENCE EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 EXISTING MONITORING WELL MW VAULT ELEC H Y CONTROL IRR H2O G EXISTING LOT LINE Northern Engineering Services, Inc. Project No. 939-001 Date: July 31, 2013 ORIGINAL FIELD SURVEY BY: 8" SS 8" W EXISTING TREES TO REMAIN EXISTING WETLANDS X CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R R R MATCHLINE-SEE SHEET C104 MATCHLINE-SEE SHEET C101 C101 C102 C103 C104 X X X X X X X X X X X X X X X X X X X TELE � D �� � 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING 100' R.O.W. LEMAY AVENUE (R.O.W. WIDTH VARIES) BUCKINGHAM STREET (32' R.O.W.) BUCKINGHAM STREET (66' R.O.W.) 10TH STREET (55' R.O.W.) ����� ������ ����� ���������� ���� ������� �������� ������ ���������� Elec Vault Elec Vault ALLEY EXISTING 20' UTILITY EASEMENT (BK. 1691 PG. 057) EXISTING 10' UTILITY AND DRAINAGE EASEMENT (REC. #97070197) EXISTING FENCE TO BE REMOVED EXISTING TREES TO BE REMOVED (TYP.) EXISTING 12" AC ELCO WATER LINE EXISTING FENCE TO BE REMOVED 5' DIA. FILLED STONE WELL EXISTING 10" PVC SANITARY (CITY OF FORT COLLINS) EXISTING 24" NWCWD WATER LINE EXISTING 24" D.I.P. CITY OF FORT COLLINS WATER LINE EXISTING 12" AC ELCO WATER LINE TO BE ABANDONED IN PLACE EXISTING 36" RCP STORM DRAIN C101 EXISTING CONDITIONS A. Reese A. Boese 1"=40' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� EXISTING ELECTRIC E LEGEND: G T EXISTING STORM DRAIN EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES TO BE REMOVED NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. REFER TO LANDSCAPE PLANS FOR TREE REMOVAL AND MITIGATION. 7. REFER TO ENVIRONMENTAL CHARACTERIZATION STUDY DATED SEPTEMBER 3, 2013 BY CEDAR CREEK ASSOCIATES FOR ADDITIONAL INFORMATION. EXISTING SANITARY SEWER EXISTING WATER EXISTING FENCE EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 EXISTING MONITORING WELL MW VAULT ELEC H Y CONTROL IRR H2O G EXISTING LOT LINE Northern Engineering Services, Inc. Project No. 939-001 Date: July 31, 2013 ORIGINAL FIELD SURVEY BY: 8" SS 8" W EXISTING TREES TO REMAIN EXISTING WETLANDS X CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP R R R R R RC101 R C102 C103 C104 MATCHLINE-SEE SHEET C103 MATCHLINE-SEE SHEET C102 Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 6feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Preliminary DrainageReport for Capstone Cottages dated May 7, 2014by Northern Engineering shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by thE construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the City of Fort Collins . 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: City of Fort Collins Benchmark3-00 On a parapet wall at the northwest end of theLincoln Ave. bridge near the northeast corner of Lincoln Ave. and Willow St. NGVD29 =4964.15 (NAVD88=4967.33) City of Fort Collins Benchmark12-07 South side of Vine Dr. on the south headwall of the bridge over Dry Creek Basin 0.4 miles east of North Lemay Ave. NGVD29 =4944.68 (NAVD88=4947.86) Basis of Bearings The Basis of Bearing is the Westline of the Northeast Quarter of said Section 7 as bearing North 00�35' 51`" East. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: 48. Approved Variances are listed as follows: CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed priorto any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. Additional information to be provided by a separate Stormwater Management Plan / Erosion Control Report for Capstone Cottages. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Preliminary DrainageReport for Capstone Cottages dated May 7, 2014by Northern Engineering shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline construction shall conform to the East Larimer County Water Districtstandards and specifications current to date of construction. 2. Allsanitary sewer construction shall conform to the City of Fort Collins standards and specifications current to date of construction. 3. A minimum cover of 4.5feet shall be maintained throughout the waterline and service line installation, particularly in areas of new grading and drainage swales. Extra bury depth may be required to maintain minimum cover at drainage culvert crossings and/or fire hydrant runs. Maximum allowable cover shall be 6 feet, unless specifically approved by the District. 4. All water piping shall be Polyvinyl Chloride (PVC). All PVC piping through 12-inch shall be manufactured in accordance with AWWA Standard C900, "Polyvinyl Chloride (PVC) Pressure Pipe, 4-inch through 12-inch, For Water Distribution", Class 150 (SDR 18). All PVC piping 14-inch through 36-inch shall be manufactured in accordance with AWWA Standard C905, "Polyvinyl Chloride (PVC) Water Transmission Pipe, Nominal Diameters 14-inch through 36", Class 200 (SDR 18). Approved manufacturers are JM Eagle, Certainteed, Gifford Hills or Carlon. Size of the pipe as shown on the approved plans. All non-metal water piping shall be installed with a twelve (12) gauge braided copper wire, plastic coated, six hundred (600) volt taped to top of pipe and surfaced at each fire hydrant. Pipe joints shall be made using an integral bell with an elastomeric gasket push-on type joint or using machined couplings of a sleeve type with rubber ring gaskets and machined pipe ends to form a push-on type joint. All materials installed shall be free of manufacturer defects. Any defective or damaged materials noted on the construction site shall be so marked and removed from the site. All fittings shall be mechanical joint, cast iron or ductile, manufactured in accordance with AWWA Standard C110. Fittings shall be furnished with a cement-mortar lining of standard thickness class with a 250 psi pressure rating. Under no circumstances shall any PVC piping be installed utilizing mechanical equipment to seat the joints. 7' PARKING 9' UTILITY EASEMENT 7' PARKING COTTAGE DRIVE (PRIVATE STREET - 83' EASEMENT) 44' 22' {}{}-{-} 51' ROW 7' PARKING 15' TRAVEL 83' ACCESS, EMERGENCY ACCESS, DRAINAGE, AND UTILITY EASEMENT 7' PARKING 15' TRAVEL 22' {}- NORTH CLUB HOUSE DRIVE (PRIVATE STREET - 73' EASEMENT) 17' {}34' -{}-{} 7' PARKING 10' TRAVEL 73' ACCESS, EMERGENCY ACCESS, DRAINAGE, AND UTILITY EASEMENT 17' {}- 7' PARKING 10' TRAVEL 41.5' {}32' -{}-{} 26' {}- 15' {}- 32' {}-41.{} 5' {}- 2.25% 2.25% 2.25% 2.25% 2.25% 2.25% 2.25% 2.25% 2.25% 2.25% 2.25% 2.25% C000 COVER SHEET A. Reese A. Boese N/A No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: May 7, 2014 PROJECT: 939-001 Sheet Of 34 Sheets CAPSTONE COTTAGES T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 5/7/14 300 N���� H���� S�����, S���� 100 F��� C������, C������� 80521 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� Ripley Design Inc. Daman Holland, ASLA, RLA 401 West Mountain Avenue Fort Collins, Colorado 80521 (970) 224-5828 Matt Delich, PE Delich Associates 2272 Glen Haven Drive Loveland, Colorado 80538 (970) 669-2061 TRAFFIC & TRANSPORTATION ENGINEERING MAY 2014 PROJECT LOCATION VICINITY MAP NORTH 1"=1500' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: BENCHMARK #1: City of Fort Collins Benchmark 3-00 NGVD29 Elevation= 4964.15 (NAVD88 Elevation= 4967.33) BENCHMARK #2: City of Fort Collins Benchmark 12-07 NGVD29 Elevation= 4944.68 (NAVD88 Elevation= 4947.86) Basis of Bearings West line of the Northeast Quarter of said Section 7 as bearing North 00°35'51" East. Northern Engineering Services, Inc. Project No. 939-001 Date: March 26, 2014 ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: CONTACT INFORMATION PROJECT TEAM: Nick Haws, PE, LEED AP Northern Engineering Services, Inc. 301 North Howes Street, Sutie 100 Fort Collins, Colorado 80521 (970) 221-4158 Gary Gilliland, PLS Northern Engineering Services, Inc. 301 North Howes Street, Sutie 100 Fort Collins, Colorado 80521 (970) 221-4158 LANDSCAPE ARCHITECT CONTACT INFORMATION PROJECT TEAM: Capstone Collegiate Communities John Acken 431 Office Park Drive Birmingham, Alabama 35223 (205) 414-6400 SHEET INDEX C000 C001 C101-104 E N G I N E E R I N G � � � � � � �� E N G I N E E R I N G � � � � � � �� UTILITY CONTACT LIST: * UTILITY COMPANY PHONE NUMBER ARCHITECT Dungan Nequette Architects Louis Nequette, AIA 1906 Cahaba Road Mountain Brook, Alabama 35223 (205) 329-7088 C400 C600 COVER SHEET GENERAL AND CONSTRUCTION NOTES EXISTING CONDITIONS OVERALL GRADING PLAN DRAINAGE EXHIBIT LOCATED IN THE WEST HALF OF SECTION 7, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO CAPSTONE COTTAGES UTILITY PLANS FOR OWNER/APPLICANT SITE ENGINEER SURVEYOR TRAFFIC ENGINEER GAS----------------- Xcel Energy---------------------------------Stephanie Rich (970) 225-7828 ELECTRIC-------- City of Fort Collins Light & Power-----Doug Martine (970) 224-6152 CABLE------------- Comcast------------------------------------- Don Kapperman (970) 567-0245 TELECOM.--------CenturyLink Local Network------------- Robert Rulli (970) 490-7503 WATER------------ ELCO Water District---------------------- Randy Siddens (970) 493-2044 WATER------------ North Weld County Water District-----Eric Larson (970) 356-3020 WASTEWATER--City of Fort Collins------------------------ Roger Buffington (970) 212-2900 STORMWATER- City of Fort Collins Utilities--------------Glen Schlueter (970) 224-6065 SANITATION----- Boxelder Sanitation District-------------Eric Garner (970) 498-0604 * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. C300 OVERALL UTILITY PLAN C401-C404 GRADING PLANS C301-C304 UTILITY PLANS ■���� �������� ■��������� ������������ ■ ■����� ������ ■����������� ■ C501-C516 ROADWAY PLAN & PROFILES GEOTECHNICAL ENGINEER Eric D. Bernhart, PE Terracon Consulting Engineers & Scientists 1901 Sharp Point Drive, Suite C Fort Collins, Colorado 80525 (970) 484-0359 C200 PAVING PLAN ENVIRONMENTAL CONSULTANTS Steven Long Cedar Creek Associates, Inc. 5586 Overhill Drive Fort Collins, Colorado 80525 (970) 223-0775 MANAGER DATE: APPROVED: DATE: APPROVED: ELCO WATER DISTRICT UTILITY PLAN APPROVAL SYSTEMS ENGINEER