Loading...
HomeMy WebLinkAboutBELLA VIRA FILING 2 - MJA/FDP - FDP140001 - SUBMITTAL DOCUMENTS - ROUND 2 - UTILITY PLANSPROJECT SITE COLORADO EQUINE RESEARCH OVERLAND TRAIL W. ELIZABETH STREET PRELIMINARY UTILITY PLANS FOR BELLA VIRA SUBDIVISION FILING TWO BEING A REPLAT OF TRACT A, BELLA VIRA SUBDIVISION, PART OF THE SOUTHEAST QUARTER OF SECTION 17, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO FEBRUARY 2014 THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO STANDARDS AND STATUTES, RESPECTIVELY; AND THAT I AM FULLY RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN, REVISIONS, AND RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS. KEVIN BRAZELTON, PE #38837 DATE SCALE: 1"=400' VICINITY MAP COVER SHEET C0.00 BELLA VIRA TOWNHOMES INC. 1313 FAIRWAY FIVE DRIVE FORT COLLINS, CO 80525 PHONE: 970-690-2662 CONTACT: JOHN MINATTA UNITED CIVIL DESIGN GROUP, LLC 1501 ACADEMY CT., STE 203 FORT COLLINS, CO 80524 PHONE: 970-530-4044 CONTACT: KEVIN BRAZELTON LOCKWOOD ARCHITECTS, INC. 415 E. PITKIN STREET FORT COLLINS, CO 80524 PHONE: 970-493-1023 CONTACT: COURTNEY LOCKWOOD LOCKWOOD ARCHITECTS, INC. 415 E. PITKIN STREET FORT COLLINS, CO 80524 PHONE: 970-493-1023 CONTACT: DANA LOCKWOOD KING SURVEYORS, INC. 650 GARDEN DRIVE WINDSOR, CO 80550 PHONE: 970-686-5011 CONTACT: LARRY PEPEK 12. The developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period, the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S standards. All signage and striping shall fall under the requirements of the two year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize windblown sediment. The developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (striping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPS are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the city/county. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: A. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. B. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. C. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the developer shall be responsible for the cleanup and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The storm water volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the city/county or Homeowners Association (HOA). 13. City ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The developer shall implement whatever measures are determined necessary, as directed by the city/county. 16. A vehicle tracking control pad shall be installed when needed for construction equipment, including but not limited to personal vehicles exiting existing roadways. No earthen materials, i.e. stone, dirt, etc. shall be placed in the curb & gutter or roadway as a ramp to access temporary stockpiles, staging areas, construction materials, concrete washout areas, and/or building sites. 1. Water mains shall be DIP with polywrap or PVC with tracer wire. 2. Water mains shall be installed with 4.5 to 5.5 feet of cover unless otherwise approved. 3. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal box and tracer wire test lid per City Water Detail 25. 1. All materials, workmanship, and construction of public improvements shall meet or exceed the Standards and Specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the local entity. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the local entity engineer. Use of these plans after the expiration date will require a new review and approval process by the local entity prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the local entity, as beneficiary of said PROPERTY BOUNDARY (TYP.) PROPERTY BOUNDARY (TYP.) WEST ELIZABETH IMPROVEMENTS CURRENTLY UNDER CONSTRUCTION (SEE NOTE 1) EXISTING 20' E.A.E. EXISTING 20' UTILITY ESMT. EXISTING 10' WATERLINE ESMT. EXIST. 15' U.E. EXISTING 75' UNITED STATES ESMT. 107.5' PUBLIC RIGHT-OF-WAY EXIST. 9' UTIL. ESMT. 51' PUBLIC RIGHT-OF-WAY EXISTING 8" SANITARY STUB (SEE NOTE 1) EXISTING 8" WATER STUB (SEE NOTE 2) EXISTING 8" WATER STUB (SEE NOTE 2) APPROXIMATE LOCATION OF EXISTING 36" WATERLINE EXISTING 12" HDPE DRAIN PIPE EXISTING 8" HDPE DRAIN PIPE EXISTING HEADWALL INV. 5113.1 (12" HDPE) INV. 5112.9 (8" HDPE) CENTERLINE OF PLEASANT VALLEY AND LAKE CANAL OVERLAND TRAIL WIDENING IMPROVEMENTS CURRENTLY UNDER CONSTRUCTION (SEE NOTE 1) EXISTING 16" WATERLINE EXISTING 8" WATERLINE EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT EXISTING OVERHEAD LIGHT (TYP.) REMOVE EXISTING FENCE TO PROPERTY LINE EXISTING WAPA N:1452824.62 E:3102165.78 N:1452822.18 E:3102208.89 Lot 7 Lot 1 Lot 2 Lot 6 Lot 5 Lot 4 Lot 3 Lot 12 Lot 11 Lot 8 Lot 13 Lot 15 Lot 14 Lot 16 Lot 17 Lot 10 Lot 9 Lot 25 Lot 24 Lot 23 Lot 22 Lot 21 Lot 20 1 2 2 2 2 1 2 2 3 3 3 3 4 4 4 4 LANDSCAPE WALL (SEE NOTE 4) LANDSCAPE SCREEN WALL AND MONUMENT SIGN (SEE NOTE 4) REAR PATIO OR DECK (TYP.) (SEE ARCH. PLANS) LOT LINE (TYP.) 2' CONCRETE PAN SCREEN WALL (SEE NOTE 4) LANDSCAPE WALL (SEE NOTE 4) LANDSCAPE WALL (SEE NOTE 4) SEE SHEET C5.0 FOR STREET PLAN & PROFILE REMOVE EXISTING PLUG TIE-IN TO EXISTING N=1452815.07 E=3102112.08 SEE NOTE #2 8" 22.5° & 11.25° BEND W/T.B. N=1452793.14 E=3102113.94 S4°50'16.46"E 22.00' S36°27'47.02"E 38.89' 8" 11.25° BEND W/T.B. N=1452761.87 E=3102137.05 S47°27'47.02"E 142.44' 8" 22.5° BEND W/T.B. N=1452665.57 E=3102242.01 8" 22.5° BEND W/T.B. N=1452659.62 E=3102256.18 S67°13'05.73"E 15.37' S89°43'05.73"E 87.38' 8" x 6" SWIVEL TEE W/T.B. 6" GATE VALVE (N) N=1452659.19 E=3102343.56 FH ASSEMBLY N=1452671.39 E=3102343.62 FLANGE=5129.19 S89°43'05.73"E 16.39' 8" 45° BEND W/T.B. N=1452659.11 E=3102359.95 N45°16'54.27"E 27.51' 8" 45° BEND W/T.B. N=1452678.47 E=3102379.50 N0°16'54.27"E 52.51' 8" 22.5° BEND W/T.B. N=1452730.97 E=3102379.75 N12°49'44.58"W 120.59' REMOVE EXISTING PLUG TIE-IN TO EXISTING N=1452848.56 E=3102352.98 SEE NOTE #2 8" SANITARY SEWER (SEE SANITARY SEWER PLAN & PROFILE C3.01) 5115 5120 5125 5130 5135 5140 5115 5120 5125 5130 5135 5140 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 15+75 51.93 LF 8" PVC @ 0.40% 185.52 LF 8" PVC @ 0.40% 119.76 LF 8" PVC @ 0.40% 35.80 LF 8" PVC @ 0.40% 57.81 LF 8" PVC @ 0.40% 89.84 LF 8" PVC @ 0.40% MH A-3 STA: 13+57.21 RIM = 5128.77 DEPTH = 6.67' INV. IN = 5122.20 (NE) INV. OUT = 5122.10 (W) MH A-1 STA: 10+51.93 RIM = 5128.42 DEPTH = 7.74' INV. IN = 5120.78 (SE) INV. OUT = 5120.68 (N) MH A-2 STA: 12+37.46 RIM = 5125.20 DEPTH = 3.68' INV. IN = 5121.62 (E) INV. OUT = 5121.52 (NW) MH A-4 STA: 13+93.01 RIM = 5129.77 DEPTH = 7.43' INV. IN = 5122.44 (N) INV. OUT = 5122.34 (SW) MH A-5 STA: 14+50.82 RIM = 5131.62 DEPTH = 8.95' INV. IN = 5122.77 (N) INV. OUT = 5122.67 (S) MH A-6 STA: 15+40.66 RIM = 5134.57 DEPTH = 11.43' INV. OUT = 5123.13 (S) STA: 12+30.57 INV.= 5118.03' PROP. 10" HDPE STORM PROPOSED GRADE EXISTING GROUND EXMH 5110 5115 5120 5125 5130 5135 5110 5115 5120 5125 5130 5135 EG=5116.0 FG=5115.42 9+50 EG=5116.6 FG=5117.14 10+00 EG=5118.0 FG=5125.47 10+50 EG=5122.2 FG=5126.09 11+00 EG=5127.6 FG=5126.54 11+50 EG=5129.4 FG=5127.54 12+00 49.25 LF 18" HDPE @ 1.00% 79.77 LF 10" HDPE @ 1.50% 33.63 LF 10" HDPE @ 1.50% 10.21 LF 10" HDPE @ 1.50% 45.43 LF 10" HDPE @ 1.50% INLET 1-7 STA 12+24.84 RIM 5127.6± INV. IN 5125.00 (E) INV. OUT 5123.50 (SE) INLET 1-4 STA 11+35.56 RIM 5126.3± INV. IN 5122.16 (N) INV. OUT 5119.02 (SW) INLET 1-2 STA 10+52.62 RIM 5125.4± INV. IN 5117.83 (NW) INV. OUT 5117.63 (S) SUMP 5113.13 BEND 1-6 (11.25°) STA 11+79.40 INV. 5122.82 BEND 1-5 (22.5°) STA 11+69.19 INV. 5122.67 HEADWALL 1 STA 10+00.00 INV. 5117.14 SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF Lot 21 Lot 20 Lot 1 Lot 2 Lot 3 Lot 25 Lot 24 Lot 23 Lot 22 Lot 7 Lot 6 Lot 5 Lot 4 Lot 12 Lot 8 Lot 11 Lot 13 Lot 15 Lot 14 Lot 16 Lot 17 Lot 10 Lot 9 ROOF DRAIN (SEE SHEET C3.02) STORM LINE 1 (SEE SHEET C3.02) 2' SIDEWALK CHASE BIOSWALE WITH UNDERDRAIN (SEE DETAILED GRADING PLAN & DETAILS) BUILDING 4 BUILDING 3 BUILDING 2 BUILDING 1 BUILDING 5 BUILDING 6 2-FOOT CONCRETE PAN 2' SIDEWALK CHASE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C4.01-C4.03_DETAILED GRADING P 2/11/2014 8:42:04 AM SME DETAILED GRADING PLAN C4.01 N/A 10' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 10' 20' SCALE: 1" = 10' 5' LOT LINES / R.O.W. EASEMENT LINES CENTERLINE CURB & GUTTER LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR SIDEWALK CHASE STORM SEWER STORM INLET RETAINING WALL NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF BUILDING 3 BUILDING 2 Lot 7 Lot 12 Lot 8 Lot 11 Lot 13 Lot 10 Lot 9 LANDSCAPE WALL TOW=5120.00 PATIO PATIO PROVIDE (1) 5" RISER PROVIDE (3) 7" RISER MAX. PROVIDE (1) 6" RISER PROVIDE (1) 5" RISER PATIO PATIO PATIO PROVIDE (2) PATIO RISERS (7" MAX.) RAMP LANDSCAPE WALL TOW=5119.90 LANDSCAPE WALL TOW=5130.70 PATI PATIO REFER TO SHEET C5.00 FOR STREET PLAN & PROFILE BIOSWALE WITH 4" PERFORATED UNDERDRAIN (SEE DETAILS) END BIOSWALE AND PERFORATED UNDERDRAIN INV.=5115.38 (SEE DETAILS) EXTEND SOLID WALL HDPE PIPE TO POND @ 1% MINIMUM SLOPE 28" CONCRETE PAN VERTICAL CURB 2-FOOT CURB CUT AND SIDEWALK CHASE RISERS (7" MAX.) PROPERTY BOUNDARY SEE GRADING DETAIL 'A' 5' MIN. END SWALE DAYLIGHT 4" HDPE PIPE INV. 5114.76 UTILITY CROSSING 4" UNDERDRAIN INV. 5115.11 12" HDPE T.O.P.=5114.6± 8" HDPE T.O.P.=5114.2± UTILITY CROSSING BUILDING 2 BUILDING 1 Lot 7 Lot 6 Lot 10 Lot 9 Lot 8 PROVIDE (1) 5" RISER PATIO PATIO PATIO PATIO PROVIDE (2) RISERS (7" MAX.) RAMP LANDSCAPE WALL TOW=5119.90 GRADE BREAK LANDSCAPE WALL TOW=5130.70 PATIO REFER TO SHEET C5.00 FOR STREET PLAN & PROFILE GRADE BREAK PRIVACY FENCE (SEE LANDSCAPE PLANS) BIOSWALE WITH 4" PERFORATED UNDERDRAIN (SEE DETAILS) PROVIDE 4" CLEANOUT INV. 5116.75 END BIOSWALE AND PERFORATED UNDERDRAIN INV.=5115.38 (SEE DETAILS) EXTEND SOLID WALL HDPE PIPE TO POND @ 1% MINIMUM SLOPE MATCH EXISTING SIDEWALK (SEE NOTE 2) 28" CONCRETE PAN VERTICAL CURB 2-FOOT CURB CUT AND SIDEWALK CHASE LOT LINE (TYP.) 5' MIN. UTILITY CROSSING 4" UNDERDRAIN INV. 5115.25 36" WATER T.O.P.=5111.2± (ASSUMED 4.5' FROM EXISTING GROUND) RAMP T T DRIVE-OVER CURB & GUTTER LANDSCAPE WALL TOW=5121.90 BLOCK 1 HABITAT BUFFER (TYP.) PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or BUILDING 1 BUILDING 5 BUILDING 6 Lot 1 Lot 2 Lot 5 Lot 4 Lot 3 Lot 25 Lot 24 Lot 23 Lot 22 Lot 21 Lot 20 GRADE BREAK PATIO PATIO PATIO PATIO PATIO PATIO PATIO PATIO PATIO PATIO REFER TO SHEET C5.00 FOR STREET PLAN & PROFILE ROOF DRAINS SEE SHEET C3.02 PROVIDE (1) 6" RISER PROVIDE (2) RISERS (7" MAX.) LANDSCAPE WALL TOW=5133.30 PROVIDE (1) 6" RISER PROVIDE (2) RISERS (7" MAX.) LANDSCAPE WALL TOW=5136.20 MATCH EXISTING INTERSECTION (SEE NOTE 2) MATCH EXISTING SIDEWALK MATCH EXISTING SIDEWALK PRIVACY FENCE AND MONUMENT SIGN (SEE LANDSCAPE PLANS) MATCH EXISTING SIDEWALK (SEE NOTE 2) VERTICAL CURB & GUTTER 28" CONCRETE PAN DRIVE-OVER CURB & GUTTER 2-FOOT CONCRETE PAN 5115 5120 5125 5130 5135 5140 5115 5120 5125 5130 5135 5140 EG=5129.0 FG= 10+00 EG=5126.7 FG=5128.88 10+50 EG=5126.4 FG=5128.00 11+00 EG=5126.3 FG=5126.99 11+50 EG=5124.3 FG=5126.09 12+00 EG=5120.0 FG=5125.19 12+50 EG=5119.1 FG=5126.39 13+00 EG=5121.2 FG=5128.03 13+50 EG=5126.4 FG=5129.68 14+00 EG=5128.8 FG=5131.32 14+50 EG=5130.5 FG=5132.96 15+00 EG=5132.3 FG=5134.61 15+50 EG=5135.4 FG= 16+00 1.50% -2.25% 0.50% 2.80% 3.29% -1.80% 1.50% -2.25% 0.50% A1 PROPOSED BIOSWALE WITH UNDERDRAIN HABITAT BUFFER (TYP.) Basin Design Point Area %I C2 C100 Q2 Q100 (acre) (cfs) (cfs) A1 A1 0.28 27% 0.45 0.57 0.35 1.55 A2 A2 0.60 35% 0.51 0.64 0.87 3.82 A3 A3 0.46 29% 0.46 0.58 0.60 2.62 A4 A4 0.78 80% 0.86 1.00 1.90 7.73 A5 A5 0.64 69% 0.77 0.96 1.39 6.07 A6 A6 0.32 47% 0.60 0.76 0.56 2.42 OS1 OS1 0.27 2% 0.25 0.31 0.16 0.68 OS2 OS2 0.10 2% 0.25 0.31 0.06 0.27 Onsite Total 3.44 47% 0.61 0.76 5.67 24.21 19 19 0.35 78% 0.82 1.00 0.82 3.52 23 23 0.06 82% 0.84 1.00 0.15 0.63 PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C6.00_DRAINAGE PLAN.DWG 2/11/2014 8:42:13 AM KRB DRAINAGE PLAN C6.00 N/A 30' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED 3 C7.00 NOT TO SCALE 2"R. 1 1/2"R. 2'-6" 6" 4 1/2" 30" 9" 4.5" 18" 3.63" 21.75" R 0.13" 7" 2" 3.75" 12" ROLL-OVER VERTICAL (LOVELAND) Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) 1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose from the post when hit by a vehicle. 2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground. Cross section of post 2 1/4" Anchor 3. Signs larger than 36 inches in length or width require wind bracing and special post design. NOTES: 4. Anchor Stub and post are square steel tube (perforated). CRITERIA FOR SINGLE POST 5. All "No Parking" signs shall be installed at 45° from Flow Line. * * 2" x 2" x 10' OR 12' 12 GAUGE TELESPAR POST (22F12A31) 2' - 3' FROM F Street Curb See Figure 16-1 R1-1 "STOP" SIGN 30" HIGH DENSITY/DIAMOND GRADE. SIGN MOUNTED TO POST WITH 1 EACH DRIVE RIVET WITH NYLON WASHER AGAINST SIGN FACE (ON TOP OF THE SIGN). THE BOTTOM OF THE SIGN SHALL BE MOUNTED WITH 1 EACH 5/16"x2-1/2" HEW BOLT WITH METAL AND FROM NYLON WASHERS (NYLON WASHER AGAINST SIGN FACE) AND SECURED WITH 1 EACH 5/16" HEX NUT ON THE BACK SIDE OF POST. L 2-1/4" x 2-1/4" x 3' ANCHOR/STUB 2 EACH 8" BLADES MOUNTED TO POST WITH 4 EACH DRIVE RIVETS WITH NYLON WASHERS ATTACHED SIDEWALK DETAIL NOTE: Construct sidewalk with joints at 10' intervals R 1/8" WEAKENED PLANE JOINT EXPANSION JOINT R1/4" and aligned with scoring on curb. INSTALL IN LOCATIONS SPECIFIED IN CHAPTER 22 1/2" 1/4" 1/4 SLAB THICKNESS 1/4" 1/2" Expansion Joint material DETACHED SIDEWALK DETAIL Variable Landscaping 2' min. Slope: Minimum 1 4"/ft Maximum 3"/ft PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP 2/11/2014 8:42:43 AM SME CONSTRUCTION DETAILS C7.01 N/A N/A 1. THE ABOVE PAVEMENT SECTION WAS TAKEN FROM THE CTL THOMPSON INC. REPORT ENTITLED "PRELIMINARY GEOTECHNICAL INVESTIGATION, BELLA VIRA TOWNHOMES, ELIZABETH STREET AND OVERLAND TRAIL, FORT COLLINS, CO", DATED SEPTEMBER 19, 2013, CTL PROJECT NO. FC06266-115. REFER TO THIS REPORT FOR PERFORMANCE SPECIFICATIONS AND OTHER RECOMMENDATIONS. 2. CONTRACTOR SHALL NOTE THAT, PER THE REFERENCED GEOTECHNICAL REPORT, THE ABOVE REFERENCED PAVEMENT SECTION IS PRELIMINARY IN NATURE AND FOR BIDDING/PLANNING PURPOSES ONLY. CONTRACTOR SHALL CONTRACT A GEOTECHNICAL ENGINEER TO PROVIDE A FINAL PAVEMENT SECTION DESIGN AFTER UNDERGROUND UTILITIES ARE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP 2/11/2014 8:42:43 AM SME CONSTRUCTION DETAILS C7.02 N/A N/A GENERAL NOTES: NOT TO SCALE COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 LOWER LIMIT OF TRENCH WALL SLOPING INITIAL LIFT * 12 IN. MIN. PIPE O.D. 4 IN. MIN. TRENCH WIDTH AS SPECIFIED IN SECTION 02221 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 * DATE REVISED: APPROVED: DRAWN BY: BEDDING REQUIREMENTS WW-1 NBJ 4/11/11 ALTERNATE BASE POURED INVERT PRECAST MANHOLE BASE SLOPE 1 IN. MIN. 8 IN. MIN. 6 IN. 15 IN. OR LESS 48 IN. 18 IN. TO 30 IN. 60 IN. OVER 30 INCHES 72 IN. MIN. MANHOLE DWG SIZE A SCALE 1:40 SHEET 1 OF 1 DWG NO. 7001-110-144 REV D 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com DRAIN BASIN WITH STANDARD GRATE QUICK SPEC INSTALLATION DETAIL TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 1-23-06 DRAWN BY EBC 1-23-06 CJA 5 ADAPTER ANGLES VARIABLE 0° - 360° ACCORDING TO PLANS A 18" MIN WIDTH GUIDELINE 8" MIN THICKNESS GUIDELINE 3 VARIABLE SUMP DEPTH ACCORDING TO PLANS (6" MIN ON 8" - 24", 10" MIN ON 30") 4" MIN ON 8" - 24" 6" MIN ON 30" MINIMUM PIPE BURIAL DEPTH PER PIPE MANUFACTURER RECOMMENDATION 3 VARIABLE INVERT HEIGHTS AVAILABLE (ACCORDING TO PLANS/TAKE OFF) THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. 4 VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE: 4" - 30" FOR CORRUGATED HDPE (ADS N-12, ADS SINGLE WALL, HANCOR DUAL WALL), SDR 35, SCH 40 DWV, CORRUGATED & RIBBED PVC WATERTIGHT JOINT (CORRUGATED HDPE SHOWN) 1 - 8" - 30" GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05, WITH THE EXCEPTION OF THE 8" - 15" BRONZE GRATES 2 - 12" - 30" FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS. SEE DRAWING NO. 7001-110-065 4 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SDR 35 PVC 5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012, 7001-110-013, & 7001-110-014. 6 - GRATES SHALL MEET H-10 LOAD RATING FOR 12" - 24" PED 7 - GRATES SHALL MEET H-20 LOAD RATING FOR 30" PED & 12" - 30" STD & SOLID PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C7.00_DETAILS.DWG 2/11/2014 8:42:43 AM SME CONSTRUCTION DETAILS C7.04 N/A N/A NOT TO SCALE 1 C-7.04 CDOT TYPE R INLET DETAILS 2 C7.04 NOT TO SCALE NOTES: 1. CONTRACTOR SHALL ALSO INSTALL BIO-SKIRTS FOR THE SNOUT. 21.4737 1.2632 7.5790 12.6315 ‘ 9.4737 18.9474 16.4211 REMOVABLE WATERTIGHT ACCESS PORT, 10" OPENING 6.3158 1" PVC ANTI-SIPHON PIPE ADAPTER BMP, INC. 53 MT. ARCHER ROAD, LYME, CT. 06371 (800) 504-8008 FAX: (860)434-3195 DESCRIPTION DRAWING NUMBER DATE SCALE 24F SNOUT OIL & DEBRIS STOP 24F 09/20/99 NONE FRONT SIDE PLAN PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C7.00_DETAILS.DWG 2/11/2014 8:42:43 AM SME CONSTRUCTION DETAILS C7.05 N/A N/A SF SF APPROVED: DATE: DRAWN BY: 12/27/00 NBJ APPROVED: DATE: DRAWN BY: NBJ 11-29-2000 APPROVED: DATE: DRAWN BY: 01/03/01 NBJ IP ECB BIO 1 C7.05 NOT TO SCALE NOTES: 1. REFER TO THE CITY OF FORT COLLINS BIORETENTION SAND MEDIA SPECIFICATION FOR MORE INFORMATION ON THE SOIL MIX. 2. BIORETENTION SAND MEDIA SHALL BE PROVIDED BY HAGEMAN EARTH CYCLE OR APPROVED EQUAL. NOTES: 1. CONTRACTOR SHALL PLACE HDPE IMPERVIOUS MEMBRANE ON BOTH SIDES OF BIOSWALE. 2. IMPERVIOUS MEMBRANE NOT REQUIRED FOR EITHER SIDE OF LEVEL SPREADER. 5' MIN. WIDTH MINIMUM 30-MIL HDPE IMPERVIOUS MEMBRANE MINIMUM 12" THICK BIORETENTION SAND MEDIA LAYER CWA VEHICLE CONTROL TRACKING PAD NOT TO SCALE CONCRETE WASHOUT AREA NOT TO SCALE 1 C7.06 2 C7.06 PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C7.00_DETAILS.DWG 2/11/2014 8:42:43 AM SME CONSTRUCTION DETAILS C7.06 N/A N/A WATTLE INSTALLATION DETAIL NOT TO SCALE 3 C7.06 VTC ROCK SOCK NOT TO SCALE 4 C7.06 S1.00 ABBREVIATIONS, DETAIL REFERENCE KEY & LAPS S1.01 GENERAL STRUCTURAL NOTES S2.00 HEADWALL/WINGWALL PLAN &DETAILS AB ANCHOR BOLT ACI AMERICAN CONCRETE INSTITUTE ADDIT. ADDITIONAL AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INC ALT ALTERNATE ALUM ALUMINUM ARCH ARCHITECTURAL ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS ASD ALLOWABLE STRESS DESIGN @ AT & AND BLK BLOCK BLKG BLOCKING BM. BEAM BO BOTTOM OF BOE BOTTOM OF EXCAVATION BOF BOTTOM OF FOOTING BOT. BOTTOM BOW BOTTOM OF WALL BRG. BEARING BS BOTH SIDES BTWN BETWEEN CJ CONTROL JOINT CL CENTER LINE CLMN COLUMN CLR CLEAR CMU CONCRETE MASONRY UNIT CONC CONCRETE CONN CONNECTION CONT CONTINUOUS CONST CONSTRUCTION COORD COORDINATE CTR CENTER DBL DOUBLE DIA OR Ø DIAMETER DIM DIMENSIONS DIST DISTRIBUTED DL DEAD LOAD DTL DETAIL DWG DRAWING EA EACH EE EACH END EF EACH FACE EJ EXPANSION JOINT ELEV ELEVATION EMBED EMBEDMENT ENGR ENGINEEER EQ EQUAL EQUIP EQUIPMENT EQUIV EQUIVALENT ES EACH SIDE EXP. JNT. EXPANSION JOINT EXT EXTERIOR EW EACH WAY FG FINISH GRADE A. 1. THE FOLLOWING CODES AND STANDARDS INCLUDING ALL SPECIFICATIONS REFERENCED WITHIN SHALL APPLY TO THE DESIGN, CONSTRUCTION, QUALITY CONTROL, AND SAFETY OF ALL WORK PERFORMED ON THE PROJECT ALONG WITH OSHA REGULATIONS AND ALL AMMENDMENTS ADOPTED BY THE LOCAL JURISDICTION. 1.1. CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, LATEST EDITION 1.2. AASHTO STANDARD SPECIFICATIONS FOR BRIDGES, LATEST EDITION. 1.3. ADDITIONAL CODES FOR SPECIFIC MATERIALS SHALL BE FOUND IN THE APPROPRIATE SECTIONS THAT FOLLOW. B. 1. DESIGN LOADING HEADWALLS 1.1. ALLOWABLE BEARING PRESSURE: 1,500 POUNDS PER SQUARE FOOT 1.2. ACTIVE LATERAL EARTH PRESSURE: 60 POUNDS PER SQUARE FOOT 1.3. PASSIVE EARTH PRESSURE: 300 POUNDS PER SQUARE FOOT 1.4. SLIDING COEFFICIENT: 0.35 1.5. UNIT SOIL WEIGHT: 120 POUNDS PER CUBIC FOOT 2. 1. DIMENSIONS AND LOCATIONS SHOWN ARE BASED ON CIVIL FURNISHED PLANS. ALL DIMENSIONS AND LOCATIONS SHALL BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. ANY DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 2. CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND DIMENSIONS THAT MAY AFFECT THE INSTALLATION OF THE STRUCTURE AS SHOWN PRIOR TO STARTING WORK. 3. THESE DRAWINGS REPRESENT THE COMPLETED PROJECT WHICH HAS BEEN DESIGNED FOR THE WEIGHTS OF MATERIALS INDICATED ON THE DRAWINGS AND FOR THE SUPERIMPOSED LOADS INDICATED ON THE DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ALLOWABLE CONSTRUCTION LOADS AND TO PROVIDE PROPER DESIGN AND CONSTRUCTION OF FALSEWORK, STAGINGS, BRACING, SHEETING, SHORING, ETC. 4. THE DEVELOPMENT AND IMPLEMENTATION OF JOB SITE SAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 5. NO STRUCTURAL MEMBERS SHALL BE CUT, NOTCHED, OR OTHERWISE PENETRATED UNLESS SPECIFICALLY APPROVED BY THE ENGINEER IN ADVANCE OR AS SHOWN ON THE APPROVED DRAWINGS. 6. THE CONTRACTOR SHALL PROVIDE ADEQUATE FOUNDATIONS, FRAMING, AND/OR SUPPORTS FOR ITEMS INDICATED ON CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, OR OTHER DRAWINGS. 7. IN CASE OF CONFLICT BETWEEN THE GENERAL NOTES, DRAWINGS, DETAILS, AND SPECIFICATIONS THE MOST RIGID REQUIREMENTS SHALL GOVERN. D. 1. ABUTMENTS, WINGWALLS, AND FOUNDATIONS HAVE BEEN DESIGNED PER PRELIMINARY & ASSUMED VALUES FROM CTL THOMPSON AS SHOWN ABOVE. CTL SHALL PERFORM AN EXCAVATION OBSERVATION AT THE HEADWALL PRIOR TO CONSTRUCTION AND PROVIDE A LETTER CONFIRMING SOIL DESIGN VALUES ARE ACCEPTABLE PRIOR TO CONSTRUCTION. E. 1. STRUCTURE EXCAVATION AND BACKFILL SHALL BE IN ACCORDANCE WITH CDOT STANDARD PLANS, LATEST EDITION, UNO. 2. STRUCTURE BACKFILL FOR THE ABUTMENT AND SIPHON WINGWALLS SHALL BE FREE-DRAINING, GRANULAR, AND CONFORM TO CDOT CLASS I STRUCTURAL BACKFILL, INSTALLED PER CDOT SPECIFICATIONS SECTION 206. 3. ALL WING WALL FOOTINGS AND BOX CULVERT SLABS SHALL BEAR ON NATIVE SOILS OR WELL COMPACTED FILL, U.N.O. ALL STRUCTURAL FILL SHALL BE PLACED UNDER THE DIRECTION OF THE PROJECT GEOTECHNICAL ENGINEER. 4. IF THE EXCAVATION BOTTOM EXPOSES WET AND VERY LOOSE MATERIAL, REMOVE AND ADD STABILIZATION MATERIALS IN ACCORDANCE WITH GEOTECHNICAL ENGINEERS RECOMMENDATIONS. 5. SOIL UNDER ALL STRUCTURES SHOULD BE SCARIFIED, MOISTURE CONDITIONED, AND COMPACTED TO 95% OF STANDARD PROCTOR. 6. THE WATER TABLE SHALL BE KEPT BELOW AND AWAY FROM THE LEVEL OF CONSTRUCTION IN ALL CASES. SOME EXCAVATIONS ARE ANTICIPATED TO ENCOUNTER SATURATED SOILS AND/OR GROUNDWATER. 7. THE FOUNDATION BEARING SURFACES ARE TO BE KEPT DRY AND STABLE UNTIL THE STRUCTURES ARE COMPLETE AND THE WALL HAVE BEEN BACKFILLED. 8. BACKFILL WALLS AND ABUTMENTS UNIFORMLY ON ALL SIDES UNTIL REACHING FINAL GRADES AND THOROUGHLY COMPACT TO 95% STANDARD PROCTOR AT 2% OPTIMUM MOISTURE CONTENT. USE ON-SITE SOILS OR IMPORTED MATERIALS AS APPROVED BY SOILS ENGINEER. FILL SHOULD BE PLACED IN MAXIMUM 8 INCH LIFTS AND BE 3" MINUS. DO NOT BACKFILL WALLS UNTIL ALL CONCRETE HAS REACHED A COMPRESSIVE STRENGTH OF 3,000 PSI, WITH A MINIMUM OF 28 DAYS PRIOR TO BACKFILLING. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL EXISTING UTILITIES, EXISTING STRUCTURES, ETC., WHETHER OR NOT SHOWN ON THE DRAWINGS THAT MAY BE AFFECTED BY THE WORK SHOWN. 10. THE CONTRACTOR SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO AT 1-800-922-1987 AT LEAST 2 DAYS PRIOR TO ANY EXCAVATION OR EARTH WORK. 11. UTILITY LINES SHALL NOT BE PLACED THROUGH OR BELOW FOUNDATIONS WITHOUT PRIOR APPROVAL FROM THE STRUCTURAL ENGINEER. 12. CONTRACTOR TO PROVIDE ALL DEWATERING, TEMPORARY SHORING, AND/OR UNDERPINNING AS NECESSARY TO PROTECT EXISTING AND ADJACENT STRUCTURES AND AS NECESSARY TO CONSTRUCT THE PROJECT, DESIGN TO BE BY CONTRACTOR OR CONTRACTOR'S ENGINEER. F. 1. REINFORCED CONCRETE CODES 1.1. AASHTO STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES, LATEST EDITION 1.2. CDOT STANDARD SPECIFICATIONS FOR ROADS AND BRIDGES, LATEST EDITION 1.3. "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318” AMERICAN CONCRETE INSTITUTE. 4 S2.00 4 S2.00 HEADWALL/1 WINGWALL PLAN 4 " =1'-0" @ HALF SCALE & 1 2 "=1'-0" @ FULL SCALE 1 4 S2.00 CONTRACTOR TO VERIFY ALL ELEVATIONS AND PIPE SIZES PER CIVIL PLANS. NOTIFY STRUCTURAL ENGINEER OF ANY DISCREPENCIES CONTRACTOR TO PREPARE BASE/SUBGRADE PER SOILS REPORT 2 HEADWALL/WINGWALL ELEVATION - 1 4 " =1'-0" @ HALF SCALE & 1 2 "=1'-0" @ FULL SCALE 3 CORNER BAR DETAIL - 1 4 " =1'-0" @ HALF SCALE & 1 2 "=1'-0" @ FULL SCALE 4 TYPICAL WINGWALL SECTION - 1 4 " =1'-0" @ HALF SCALE & 1 2 "=1'-0" @ FULL SCALE S2.00 1.4. "ACI MANUAL OF CONCRETE PRACTICE” - PARTS 1 THROUGH 5. 1.5. "MANUAL OF STANDARD PRACTICE,” CONCRETE REINFORCING STEEL INSTITUTE. 2. REINFORCED CONCRETE MATERIALS 2.1. SUBMIT CONCRETE MIX DESIGNS TO THE ENGINEER AND OBTAIN APPROVAL PRIOR TO PLACEMENT OF ANY CAST-IN-PLACE CONCRETE TO MEET THE FOLLOWING STRENGTHS: 2.2. STRUCTURAL CONCRETE f'c: 4,500 PSI @ 28 DAYS 2.3. AGGREGATES: ¾” MAX. ASTM C33 (NORMAL WEIGHT) 2.4. CEMENT: ASTM C-150 TYPE I OR II 2.5. W/C RATIO: 0.50 MAX SLUMP: 4” MAX 2.6. AIR: 6% +/- 1.5% FOR EXPOSED CONCRETE, ADMIXTURE TO COMPLY WITH ASTM C260 3. ALL EXPOSED EDGES OF CONCRETE SHALL HAVE 3 4" CHAMFER, U.N.O. 4. EXPANSION JOINT MATERIAL: SHALL MEET AASHTO SPECIFICATION M-213 5. ALL CONCRETE IN CONTACT WITH SOIL SHALL BE SULFATE RESISTING 6. REINFORCING STEEL: DEFORMED BARS, ASTM A615, GRADE 60 EXCEPT TIE BARS TO BE GRADE 40. WELDED BARS TO CONFORM TO ASTM 706. 7. WELDED WIRE FABRIC: ASTM A185 OR A496 8. REINFORCED CONCRETE NOTES: 8.1. COLD WEATHER: MAINTAIN CONCRETE CURING TEMPERATURE ABOVE 50 ºF FOR A MINIMUM OF 3 CONSECUTIVE DAYS. 8.2. PLACE REINFORCEMENT WITH CHAIRS AND ACCESSORIES NECESSARY TO SUPPORT REINFORCEMENT AT POSITIONS SHOWN ON DRAWINGS. FORM TIES, WOOD, BRICK, OR OTHER MATERIALS WILL NOT BE ALLOWED FOR SUPPORT OF REINFORCEMENT. 8.3. REINFORCING AND EMBEDMENT ITEMS SHALL BE FREE OF EXCESSIVE SCALE OR RUST, DIRT, GREASE, OIL, OR ANY OTHER SUBSTANCE THAT WILL IMPAIR BOND WITH CONCRETE. 8.4. CONSTRUCTION JOINTS NOT SHOWN ON THE PLANS SHALL BE PRE-APPROVED BY THE STRUCTURAL ENGINEER. JOINTS SHALL BE THOROUGHLY CLEANED AND ROUGHENED PRIOR TO PLACING CONCRETE. 8.5. PROVIDE LAPS LENGTHS AS SHOWN AT ALL SPLICES 8.6. THE FOLLOWING MINIMUM COVER OVER REINFORCING SHALL BE PROVIDED UNLESS DETAILED OTHERWISE: 8.6.1. CONCRETE CAST AGAINST PERMANENTLY EXPOSED EARTH - 3” 8.6.2. CONCRETE EXPOSED TO EARTH OR WEATHER, #5 BAR & SMALLER - 1 1/2”; #6 THROUGH #18 BARS - 2” G. 1. SHOP DRAWINGS & SUBMITTALS: 1.1. THE CONTRACTOR SHALL CHECK AND STAMP ALL SHOP DRAWINGS PRIOR TO FORWARDING TO THE ENGINEER FOR REVIEW. 1.2. THE CONTRACTOR SHALL PROVIDE 1 ORIGINAL AND 2 PRINTS OF ALL SHOP DRAWINGS AND SUBMITTALS FOR REVIEW INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1.2.1. CONCRETE MIX DESIGNS, REINFORCING STEEL, STRUCTURAL STEEL, COLD-FORMED STRUCTURAL STEEL FRAMING I. 1. ALL SITE SOILS WORK, GRADING, AND FOUNDATION EXCAVATIONS SHALL BE REVIEWED BY THE PROJECT GEOTECHNICAL ENGINEER PRIOR TO PLACING ANY FORMWORK OR REINFORCING. A LETTER STAMPED BY A REGISTERED PROFESSIONAL ENGINEER STATING THAT DESIGN ALLOWABLE BEARING PRESSURES AND FOUNDATION SYSTEM ARE ACCEPTABLE AS SHOWN ON THE CONSTRUCTION PLANS SHALL BE SUBMITTED. 2. LETTERS OF CONSTRUCTION COMPLIANCE: THE CONTRACTOR SHALL DETERMINE FROM THE LOCAL BUILDING DEPARTMENT WHETHER ANY LETTERS OF COMPLIANCE ARE REQUIRED AND NOTIFY THE STRUCTURAL ENGINEER PRIOR TO THE START OF CONSTRUCTION. 48 HOURS ADVANCE NOTICE SHALL BE GIVEN TO THE STRUCTURAL ENGINEER PRIOR TO REQUIRED INSPECTIONS. 3. INSPECTIONS: AS NORMALLY REQUIRED BY THE LOCAL BUILDING DEPARTMENT ANTICIPATED TO INCLUDE FOOTING AND FOUNDATION INSPECTIONS, CONCRETE SLAB INSPECTIONS, AND FRAMING INSPECTIONS. REFER TO IBC SECTION 109. 4. SPECIAL INSPECTIONS: TO BE PERFORMED BY THE PROJECT STRUCTURAL ENGINEER AND/OR AN APPROVED SPECIAL INSPECTOR RETAINED BY THE OWNER AS REQUIRED BY THE BUILDING DEPARTMENT:  STEEL: PERIODIC INSPECTIONS OF ANY WELDED OR HIGH-STRENGTH BOLTED CONNECTIONS. REFER TO IBC SECTION 1704.3.  CONCRETE: PERIODIC INSPECTIONS OF FOOTING AND FOUNDATION WALL FORMWORK, ANCHOR BOLTS AND EMBEDS, AND REINFORCEMENT PLACEMENT PRIOR TO POURING CONCRETE. DOCUMENTATION SHALL BE PROVIDED SHOWING MIX DESIGN MEETS PROJECT REQUIREMENTS FOR ALL FOUNDATION CONCRETE. REFER TO IBC SECTION 1704.4.  MASONRY: PERIODIC INSPECTION OF MORTAR PROPORTIONS, REINFORCING, AND GROUTING IN ACCORDANCE WITH IBC SECTION 1704.5, AS APPLICABLE TO THE PROJECT. 5. OBSERVATIONS: TO BE PERFORMED BY THE PROJECT STRUCTURAL ENGINEER AS REQUIRED BY THE LOCAL BUILDING DEPARTMENT AND IBC SECTION 1709.  PERIODIC OBSERVATIONS OF ALL FOOTINGS AND FOUNDATOIN WALL FORMWORK, REINFORCEMENT PLACEMENT, ANCHOR BOLT PLACEMENT TO VERIFY WORK IS IN ACCORDANCE WITH PROJECT DRAWINGS. OBSERVATIONS TO BE PERFORMED PRIOR TO CONCRETE PLACEMENT.  PERIODIC OBSERVATIONS OF FRAMING SYSTEMS AND COMPONENTS TO VERIFY WORK IS IN ACCORDANCE WITH PROJECT DRAWINGS. OBSERVATIONS TO BE PERFORMED WHILE FRAMING IS VISIBLE AND PRIOR TO ENCLOSING. S1.01 FIN FINISH FLR FLOOR FDN FOUNDATION FOC FACE OF CONCRETE FOM FACE OF MASONRY FS FAR SIDE FT OR ' FEET FTG FOOTING 1ST FIRST GA GAGE GALV GALVANIZED GEOTECH GEOTECHNICAL GR. BM. GRADE BEAM HAS HEADED ANCHOR STUD HORIZ HORIZONTAL HS HIGH STRENGTH IBC INTERNATIONAL BUILDING CODE ID INSIDE DIAMETER IN OR " INCHES INCL INCLUDE OR INCLUDING INFO INFORMATION INT INTERIOR JNT JOINT JST JOIST K KIP (1000 POUNDS OF FORCE) KCF KIP PER CUBIC FOOT KSF KIP PER SQUARE FOOT KSI KIP PER SQUARE INCH LCTN LOCATION LL LIVE LOAD LONG LONGITUDINAL LLV LONG LEG VERTICAL LRFD LOAD AND RESISTANCE FACTOR DESIGN MANUF MANUFACTURER MAS MASONRY MATL. MATERIAL MAX MAXIMUM MIN MINIMUM N/A NOT APPLICABLE NO. OR # NUMBER NS NEAR SIDE NTS NOT TO SCALE OC ON CENTER (SPACING) OD OUTSIDE DIAMETER OH OVER HEAD OPNG OPENING OPP OPPOSITE OSHA OCCUPATIONAL HEALTH AND SAFETY ADMINISTRATION PC PIECE P/C PRECAST LBS POUNDS PCI POUNDS PER CUBIC INCH PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PLT PLATE PRES. T. PRESSURE TREATED PT POINT P-T POST TENSIONING STEEL RAD RADIUS RE: REFERENCE OR REFER TO REINF REINFORCEMENT REQ'D REQUIRED RO ROUGH OPENING 2ND SECOND SECT SECTION SHT SHEET SIM SIMILAR SOG SLAB ON GRADE SP SPACES SPEC SPECIFICATION SQ SQUARE SS STAINLESS STEEL STD STANDARD STIFF STIFFENER STL STEEL STRUCT STRUCTURAL OR STRUCTURE SYM SYMMETRICAL T&B TOP AND BOTTOM THK THICK OR THICKNESS TOB TOP OF BEAM TO TOP OF TOC TOP OF CONCRETE TOF TOP OF FOOTING TOM TOP OF MASONRY TOW TOP OF WALL TR THREADED ROD TRANS TRANSVERSE TYP TYPICAL UNIF UNIFORM UNO UNLESS NOTED OTHERWISE USGS UNITED STATES GEOLOGICAL SURVEY VERT VERTICAL VIF VERIFY IN FIELD W/ WITH W/O WITHOUT WWF WELDED WIRE FABRIC SECTION OR DETAIL REFERENCE LETTER OR NUMBER SHEET NUMBER ON WHICH SECTION IS SHOWN - - SECTION LOOK DIRECTION REQUIRED REINFORCING BAR TENSION LAP SPLICE LENGTHS (INCHES) FOR CONCRETE STRENGTHS OF 4500 PSI REINFORCEMENT WITH MORE THAN 12 IN. CONCRETE CAST BELOW SPLICE ALL OTHER REINFORCEMENT CONCRETE COVER CONCRETE COVER 1" 1 1/2" 2" 1" 1 1/2" 2" #3 14 14 14 12 12 12 #4 19 19 19 14 14 14 #5 27 23 23 21 18 18 #6 38 28 28 29 21 21 #7 61 45 40 47 35 31 #8 ‐ 57 46 ‐ 44 35 #9 ‐ 70 57 ‐ 54 44 #10 ‐ 86 70 ‐ 66 54 S1.00 (SEE NOTES 1-2) MINIMUM 6" THICK PEA GRAVEL LAYER MINIMUM 8" THICK CDOT AGGREGATE NO. 4 STORAGE/ FILTRATION LAYER 4" PERFORATED UNDERDRAIN UNDISTURBED EARTH CONNECT TO PERFORATED HDPE UNDERDRAIN WITH 4" SOLID WALL HDPE PIPE BACKFILL MATERIAL FLOW DIRECTION EXTEND SOLID WALL PIPE TO POND (SEE GRADING PLAN) 9.4737 8.2105 U.S.PATENT #6126817 ADDITIONAL PATENTS PENDING 8 - ALL BRONZE GRATES, DROP IN GRATES, & 8" & 10" PED/STD GRATES & SOLID COVERS ARE RATED FOR LIGHT DUTY APPLICATIONS ONLY 9 - DOME GRATES HAVE NO LOAD RATING CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. 1 2 INTEGRATED DUCTILE IRON FRAME & GRATE TO MATCH BASIN O.D. PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP 2/11/2014 8:42:43 AM SME CONSTRUCTION DETAILS C7.03 N/A N/A PLAN VIEW SECTION A-A SECTION B-B GENERAL NOTES: B A A B DETAIL "A" APPROVED: DATE: DRAWN BY: NBJ 12/18/00 APPROVED: DATE: DRAWN BY: 1/12/00 SKC PLAN VIEW CROSS VIEW 45 ELBOW SERVICE WYE 8 IN. PVC SEWER PIPE COMPACTED GRANULAR MATERIAL AIR-TIGHT PLUG WITH 4 IN. X 4 IN. MARKER UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR LEAN CONCRETE PVC SEWER PIPE NOTE: WYE CONNECTION NOT ALLOWED ON VCP LEAN CONCRETE o 20 MIN. o 45 MAX. o TRENCH UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR 4 IN. X 4 IN. MARKER AIR-TIGHT PLUG DATE REVISED: APPROVED: DRAWN BY: SERVICE WYE DETAIL WW-9 NBJ 4/11/11 STANDARD CONCRETE NOTES APPROVED: DATE: DRAWN BY: 2/22/05 TDC NOT TO SCALE 1 C-7.03 DWGSCALE SIZE A 1:SHEET8 1 OF 1 DWG NO.7001-110-211 REV B 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 15 IN DOME GRATE ASSEMBLY TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 3-7-06 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWNEBC BY NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 3-7-06 CJA APPROX. DRAIN AREA = 115.49 SQ IN APPROX. WEIGHT WITH FRAME = 47.30 LBS 6.00 2.47 Ø 15.30 Ø 18.83 ALL DIMENSIONS IN INCHES UNLESS NOTED OTHERWISE QUALITY: MATERIAL SHALL CONFORM TO ASTM A536 GRADE 70-50-05 PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINT LOCKING DEVICE AVAILABLE UPON REQUEST SEE DRAWING NO. 7001-110-230 DUCTILE IRON .93 NYLOPLAST DRAIN BASIN DETAILS DWG SIZE A SCALE 1:1 SHEET 1 OF 1 DWG NO. 7001-110-011 REV E 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 8 IN - 30 IN SPECIFICATIONS TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 3-10-00 DRAWN BY CJA 3-10-00 CJA Section 2721 Engineered Surface Drainage Products GENERAL PVC surface drainage inlets shall include the drain basin type as indicated on the contract drawing and referenced within the contract specifications. The ductile iron grates for each of these fittings are to be considered an integral part of the surface drainage inlet and shall be furnished by the same manufacturer. The surface drainage inlets shall be as manufactured by Nyloplast, a division of Advanced Drainage Systems, Inc., or prior approved equal. MATERIALS The drain basins required for this contract shall be manufactured from PVC pipe stock, utilizing a thermo-molding process to reform the pipe stock to the specified configuration. The drainage pipe connection stubs shall be manufactured from PVC pipe stock and formed to provide a watertight connection with the specified pipe system. This joint tightness shall conform to . The flexible elastomeric seals shall conform to . The pipe bell spigot shall be joined to the main body of the drain basin or catch basin. The raw material used to manufacture the pipe stock that is used to manufacture the main body and pipe stubs of the surface drainage inlets shall conform to . The grates and frames furnished for all surface drainage inlets shall be ductile iron for sizes 8", 10", 12", 15", 18", 24", and 30" and shall be made specifically for each basin so as to provide a round bottom flange that closely matches the diameter of the surface drainage inlet. Grates for drain basins shall be capable of supporting H-20 wheel loading for traffic areas or H-10 loading for pedestrian areas. 12" and 15" square grates will be hinged to the frame using pins. Metal used in the manufacture of the castings shall conform to . Grate shall be provided painted black. INSTALLATION The specified PVC surface drainage inlet shall be installed using conventional flexible pipe backfill materials and procedures. The backfill material shall be crushed stone or other granular material meeting the requirements of class 2 material as defined in . Bedding and backfill for surface drainage inlets shall be placed and compacted uniformly in accordance with . The drain basin body will be cut at the time of the final grade. No brick, stone or concrete block will be required to set the grate to the final grade height. For H-20 load rated installations, a concrete ring will be poured under and around the grate and frame. The concrete slab must be designed taking into the consideration local soil conditions, traffic loading, and other applicable design factors. For other installation considerations such as migration of fines, ground water, and soft foundations refer to guidelines. MINIMUM INSIDE DIAMETER OF DIAMETER MANHOLE SHALL BE AS FOLLOWS: PIPE SIZE CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE ASTM C-478 ECCENTRIC CONE PRE-FORMED PLASTIC GASKET ASTM C-478 MANHOLE SECTIONS GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET CAST-IN-PLACE CONCRETE BASE 16 IN. MAX. FINISHED GRADE 28 IN. MAX. 24 IN. SEE TABLE 6 IN. 12 IN. SLOPE 1 IN./FT. 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. 8 IN. MIN DATE REVISED: APPROVED: DRAWN BY: STANDARD MANHOLE WW-3 NBJ 4/11/11 POURED INVERT 1 IN. MIN. SLOPE PRECAST MANHOLE BASE ALTERNATE BASE 6 IN. 8 IN. MIN 8 IN. MIN. 2 IN. MIN. MIN. MANHOLE PIPE SIZE MANHOLE SHALL BE AS FOLLOWS: MINIMUM INSIDE DIAMETER OF OVER 30 INCHES 18 IN. TO 30 IN. 15 IN. OR LESS DIAMETER 72 IN. 60 IN. 48 IN. PRE-FORMED PLASTIC GASKET GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET 12 IN. 6 IN. 5 FT. MAX. 1 IN./FT. SLOPE 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. AS NEEDED SEE TABLE FINISHED GRADE 16 IN. MAX. 28 IN. MAX. CAST-IN-PLACE CONCRETE BASE ASTM C-478 MANHOLE SECTIONS OF CONICAL TOP ASTM C-478 CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE NOTE: IF MANHOLE DEPTH IS LESS THAN 3 FEET, TOP SECTION SHALL HAVE A CONCENTRIC OPENING. 2 IN. MIN. FLAT SLAB TOP SECTION IN LIEU DATE REVISED: APPROVED: DRAWN BY: FLAT-TOP MANHOLE WW-5 NBJ 4/11/11 INSTALLED AND SUBGRADE IS CUT TO ROUGH GRADE. 4" HOT MIX ASPHALT 6" AGGREGATE BASE COURSE (CLASS 6) 12" TREATED SUBGRADE (SEE GEOTECHNICAL REPORT) NOT TO SCALE 1 C7.01 Sidewalk Driveway LIP F.L. T.C. DRIVEWAY SIDEWALK SECTION A-A NOTE: 1. Sidewalk grade shall remain consistent across driveway 3. This detail applies to Residential & Commercial driveways. 6" 6" Residential Detached Sidewalk Attached Sidewalk 1/2" Expansion Joint Material 1/2" Expansion Joint Material A A 2. For driveway design requirements, see CONST. DWG. 706 & 707. DETACHED ATTACHED 3'-0" 6'-0" All Sidewalk Thickness Shall Be 6" minimum. Min. SIDEWALK 8" Commercial * 12 Gauge 8" CONCRETE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP 2/11/2014 8:42:43 AM SME CONSTRUCTION DETAILS C7.00 N/A N/A 6" 2"R. 6" 6" 12" 1 1/2"R. 6" 4 1/2" ONSITE VERTICAL CURB & GUTTER Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) OUT FALL CURB & GUTTER 1" 1'-6" 6" 2"R. 1 1/2"R. 6" 4 1/2" Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) 1" 1'-6" 6" 6" 12" X=2' min. Driveway Width Varies 6" Lip FL Back of curb Right of Way line Detached Sidewalk NOTE: 1. Concrete driveway must be provided to the property line. Refer to Chapter 25 for minimum removal dimensions. X Y W X W = Width t N.T.S. SECTION A-A 2" t t X = Curb Transition Length Y = Parkway Width in Type I Approach W = Driveway Width (See Drawing 707) t = Concrete Thickness - minimum 6" Type I = With Detached Sidewalk Type II = With Attached Sidewalk TYPE I TYPE II A A PERSPECTIVE X=6'-0" B B WALK Y t t WALK JOINT EXPANSION SECTION B-B N.T.S. Ramp if necessary 1:12 max. Expansion joint if drive continues as concrete WALK 6" 12" BACKGROUND "P" RED WHITE BLACK LEGEND, CIRCLE DIAGONAL, BORDER, "ARROW", "FIRE LANE" (FORT COLLINS ONLY) 1. THE SIGN PLATE SHALL BE A MINIMUM OF 12"X18" WITH A THICKNESS OF .080 ALUMINUM CONSTRUCTION. 2. THE SIGN FACE SHALL HAVE A WHITE REFLECTIVE BACKGROUND WITH A RED LEGEND. USE THE STANDARD 3M SCOTCHLITE SIGN FACE NUMBER R7-32 OR EQUIVALENT, WITH RED LETTERING AS SHOWN ABOVE. 3. ARROWS MAY BE NEEDED (LEFT, RIGHT OR DOUBLE), TO DESIGNATE BEGIN AND END OF NO PARKING AREA. NO PARKING BY ORDER OF THE FIRE MARSHAL STANDARD FIRE LANE SIGN DETAIL UNIVERSAL FIRE LANE SIGN DETAIL 18" 2" 1 1/2" 3/4" 12" 1 C7.00 NOT TO SCALE 1" 2' CONCRETE PAN 2' 6" CONCRETE 2 C7.00 NOT TO SCALE 12' 1.5" 1-3/8" 28' 6" CONCRETE 28" CONCRETE PAN W ASPHALT W W P.C. CROSSPAN THICKENED ASPHALT THICKENED AND WALK CURB, GUTTER T = THICKNESS OF CROSSPAN W = WIDTH OF CROSSPAN P.C. *-If subgrade is flyash treated, use T instead of 2T. ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 4. LANDSCAPING WITHIN THE HABITAT BUFFER ZONE SHALL CONSIST OF NATIVE MATERIALS. REFER TO THE LANDSCAPE PLANS. 6. VEGETATIVE SWALES, THE BIOSWALE, AND THE SNOUT BMP SHALL BE MAINTAINED BY THE PROPERTY OWNER OR HOA AND FOLLOW APPLICABLE STANDARD OPERATING PROCEDURES AS SHOWN IN DRAINAGE REPORT FOR BELLA VIRA SUBDIVISION FILING TWO. LEGEND NOTES D-101 BASIN DESIGNATION BASIN AREA (ACRE) 2 - YR RUNOFF COEFF. 100 - YR RUNOFF COEFF. BASIN BOUNDARY DESIGN POINT FLOW DIRECTION 0 30' 60' SCALE: 1" = 30' 15' 2.80% 3.29% -1.80% PVI STA = 10+25.50 PVI ELEV = 5128.74 PVI STA = 11+23.11 PVI ELEV = 5127.48 PVI STA = 12+99.75 PVI ELEV = 5126.38 PVI STA = 12+59.25 PVI ELEV = 5125.24 PVI STA = 12+53.23 PVI ELEV = 5125.12 PVI STA = 12+47.20 PVI ELEV = 5125.25 50.0' VC HIGH PT EL: 5128.89 HIGH PT STA: 10+45.50 PVI STA: 10+50.50 PVI EL: 5129.11 AD: 3.75 K: 13.33 BVCS: 10+25.50 BVCE: 5128.74 EVCS: 10+75.50 EVCE: 5128.55 30.0' VC PVI STA: 15+79.89 PVI EL: 5135.59 AD: 2.79 K: 10.76 BVCS: 15+64.89 BVCE: 5135.10 EVCS: 15+94.89 EVCE: 5135.67 PROPOSED GRADE @ ROAD CENTERLINE EXISTING GROUND @ ROAD CENTERLINE PROPOSED GRADE PER JIM SELL DESIGN (SEE NOTE 2) PROPOSED GRADE PER JIM SELL DESIGN (SEE NOTE 2) PROP. 10" HDPE STORM STA.=12+55.56 INV.= 5118.12 NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C5.00_ROAD P&P.DWG 2/11/2014 12:34:58 PM SME BELLA VITA WAY & SABATINO LANE CENTERLINE PLAN & PROFILE C5.00 3' 30' 0 30' 60' SCALE: 1" = 30' 15' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com 1. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. SEE SHEET C2.00 FOR SIGNING AND STRIPING INFORMATION. 4. SEE SHEET C4.01 AND C4.02 FOR DETAILED GRADING INFORMATION AT INTERSECTIONS WITH WEST ELIZABETH STREET. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE PROPOSED CURB & GUTTER LEGEND NOTES PROVIDE (3) RISERS (7" MAX.) PROVIDE (1) 5" RISER PROVIDE (3) 6" RISERS LANDSCAPE WALL TOW=5132.90 PROVIDE (1) 5" RISER PROVIDE (2) 5" RISERS LOT LINE (TYP.) LOT LINE (TYP.) T T T T T T 30' CROWN TRANSITION BLOCK 1 2-FOOT CURB CUT AND SIDEWALK CHASE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C4.01-C4.03_DETAILED GRADING P 2/11/2014 8:42:04 AM SME DETAILED GRADING PLAN C4.04 N/A 10' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 10' 20' SCALE: 1" = 10' 5' LOT LINES / R.O.W. EASEMENT LINES CENTERLINE CURB & GUTTER LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR SIDEWALK CHASE STORM SEWER STORM INLET RETAINING WALL NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE OR EDGE OF WALK UNLESS OTHERWISE NOTED. 4. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS. 5. EXCEPT FOR THOSE BUILDING UNITS DESIGNATED AS "ADA UNITS", ALL UNITS ARE PROVIDED WITH A 6-INCH RISER FROM THE FRONT PATIO TO THE FIRST FLOOR FINISHED FLOOR. 6. REFER TO LANDSCAPE PLANS FOR DETAILS AND SPECIFICATIONS FOR ALL LANDSCAPE WALLS. REFER TO ARCHITECTURAL PLANS FOR DETAILS AND SPECIFICATIONS FOR STEPS AND HANDRAILS. 7. FINISHED FLOOR ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 8. FOR BUIDLINGS 1-4 AND BUILDING 6 THE TOP OF FOUNDATION IS EQUAL TO THE FINISHED FLOOR ELEVATION AT THE FRONT OF THE BUILDING. FOR BUILDING 5 ALL TOP OF FOUNDATION ELEVATIONS AT THE PERIMETER OF THE BUILDING ARE EQUAL TO FINISHED FLOOR. REFER TO AND COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR EACH BUILDNG FOR MORE INFORMATION. FINISHED GRADE ELEVATIONS SHOWN ADJACENT TO BUILDINGS ARE A MINIMUM OF 8-INCHES BELOW TOP OF FOUNDATION. 9. REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 10. LANDSCAPING WITHIN THE HABITAT BUFFER ZONE SHALL CONSIST OF NATIVE MATERIALS. REFER TO THE LANDSCAPE PLANS. KEYMAP NTS PROPOSED SPOT ELEVATION FF=FINISHED FLOOR FG=FINISHED GRADE AT EXTERIOR WALL TOW=TOP OF WALL LP=LOW POINT HP=HIGH POINT CURB & GUTTER TRANSITION T liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C4.01-C4.03_DETAILED GRADING PLA 2/11/2014 8:42:04 AM SME DETAILED GRADING PLAN C4.03 N/A 10' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 10' 20' SCALE: 1" = 10' 5' LOT LINES / R.O.W. EASEMENT LINES CENTERLINE CURB & GUTTER LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR SIDEWALK CHASE STORM SEWER STORM INLET RETAINING WALL NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE OR EDGE OF WALK UNLESS OTHERWISE NOTED. 4. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS. 5. EXCEPT FOR THOSE BUILDING UNITS DESIGNATED AS "ADA UNITS", ALL UNITS ARE PROVIDED WITH A 6-INCH RISER FROM THE FRONT PATIO TO THE FIRST FLOOR FINISHED FLOOR. 6. REFER TO LANDSCAPE PLANS FOR DETAILS AND SPECIFICATIONS FOR ALL LANDSCAPE WALLS. REFER TO ARCHITECTURAL PLANS FOR DETAILS AND SPECIFICATIONS FOR STEPS AND HANDRAILS. 7. FINISHED FLOOR ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 8. FOR BUIDLINGS 1-4 AND BUILDING 6 THE TOP OF FOUNDATION IS EQUAL TO THE FINISHED FLOOR ELEVATION AT THE FRONT OF THE BUILDING. FOR BUILDING 5 ALL TOP OF FOUNDATION ELEVATIONS AT THE PERIMETER OF THE BUILDING ARE EQUAL TO FINISHED FLOOR. REFER TO AND COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR EACH BUILDNG FOR MORE INFORMATION. FINISHED GRADE ELEVATIONS SHOWN ADJACENT TO BUILDINGS ARE A MINIMUM OF 8-INCHES BELOW TOP OF FOUNDATION. 9. REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 10. LANDSCAPING WITHIN THE HABITAT BUFFER ZONE SHALL CONSIST OF NATIVE MATERIALS. REFER TO THE LANDSCAPE PLANS. KEYMAP NTS PROPOSED SPOT ELEVATION FF=FINISHED FLOOR FG=FINISHED GRADE AT EXTERIOR WALL TOW=TOP OF WALL LP=LOW POINT HP=HIGH POINT CURB & GUTTER TRANSITION T 4" UNDERDRAIN INV. 5115.25 36" WATER T.O.P.=5111.2± (ASSUMED 4.5' FROM EXISTING GROUND) CONTRACTOR SHALL NOT CUT OVER EXISTING 36" WATER MAIN RAMP T T T T DRIVE-OVER CURB & GUTTER LANDSCAPE WALL TOW=5121.90 30' CROWN TRANSITION 30' CROWN TRANSITION BLOCK 1 HABITAT BUFFER (TYP.) LEVEL SPREADER WITH BIOSWALE MATERIAL 5' 30' REFER TO STRUCTURAL PLANS FOR HEADWALL DETAILS PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C4.01-C4.03_DETAILED GRADING P 2/11/2014 8:42:04 AM SME DETAILED GRADING PLAN C4.02 N/A 10' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 10' 20' SCALE: 1" = 10' 5' LOT LINES / R.O.W. EASEMENT LINES CENTERLINE CURB & GUTTER LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR SIDEWALK CHASE STORM SEWER STORM INLET RETAINING WALL NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE OR EDGE OF WALK UNLESS OTHERWISE NOTED. 4. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS. 5. EXCEPT FOR THOSE BUILDING UNITS DESIGNATED AS "ADA UNITS", ALL UNITS ARE PROVIDED WITH A 6-INCH RISER FROM THE FRONT PATIO TO THE FIRST FLOOR FINISHED FLOOR. 6. REFER TO LANDSCAPE PLANS FOR DETAILS AND SPECIFICATIONS FOR ALL LANDSCAPE WALLS. REFER TO ARCHITECTURAL PLANS FOR DETAILS AND SPECIFICATIONS FOR STEPS AND HANDRAILS. 7. FINISHED FLOOR ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 8. FOR BUIDLINGS 1-4 AND BUILDING 6 THE TOP OF FOUNDATION IS EQUAL TO THE FINISHED FLOOR ELEVATION AT THE FRONT OF THE BUILDING. FOR BUILDING 5 ALL TOP OF FOUNDATION ELEVATIONS AT THE PERIMETER OF THE BUILDING ARE EQUAL TO FINISHED FLOOR. REFER TO AND COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR EACH BUILDNG FOR MORE INFORMATION. FINISHED GRADE ELEVATIONS SHOWN ADJACENT TO BUILDINGS ARE A MINIMUM OF 8-INCHES BELOW TOP OF FOUNDATION. 9. REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 10. LANDSCAPING WITHIN THE HABITAT BUFFER ZONE SHALL CONSIST OF NATIVE MATERIALS. REFER TO THE LANDSCAPE PLANS. KEYMAP NTS PROPOSED SPOT ELEVATION FF=FINISHED FLOOR FG=FINISHED GRADE AT EXTERIOR WALL TOW=TOP OF WALL LP=LOW POINT HP=HIGH POINT CURB & GUTTER TRANSITION T SCALE: 1"=5' THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE OR EDGE OF WALK UNLESS OTHERWISE NOTED. 4. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS. 5. EXCEPT FOR THOSE BUILDING UNITS DESIGNATED AS "ADA UNITS", ALL UNITS ARE PROVIDED WITH A 6-INCH RISER FROM THE FRONT PATIO TO THE FIRST FLOOR FINISHED FLOOR. 6. REFER TO LANDSCAPE PLANS FOR DETAILS AND SPECIFICATIONS FOR ALL LANDSCAPE WALLS. REFER TO ARCHITECTURAL PLANS FOR DETAILS AND SPECIFICATIONS FOR STEPS AND HANDRAILS. 7. FINISHED FLOOR ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 8. FOR BUIDLINGS 1-4 AND BUILDING 6 THE TOP OF FOUNDATION IS EQUAL TO THE FINISHED FLOOR ELEVATION AT THE FRONT OF THE BUILDING. FOR BUILDING 5 ALL TOP OF FOUNDATION ELEVATIONS AT THE PERIMETER OF THE BUILDING ARE EQUAL TO FINISHED FLOOR. REFER TO AND COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR EACH BUILDNG FOR MORE INFORMATION. FINISHED GRADE ELEVATIONS SHOWN ADJACENT TO BUILDINGS ARE A MINIMUM OF 8-INCHES BELOW TOP OF FOUNDATION. 9. REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 10. LANDSCAPING WITHIN THE HABITAT BUFFER ZONE SHALL CONSIST OF NATIVE MATERIALS. REFER TO THE LANDSCAPE PLANS. KEYMAP NTS PROPOSED SPOT ELEVATION FF=FINISHED FLOOR FG=FINISHED GRADE AT EXTERIOR WALL TOW=TOP OF WALL LP=LOW POINT HP=HIGH POINT CURB & GUTTER TRANSITION T WEST ELIZABETH IMPROVEMENTS CURRENTLY UNDER CONSTRUCTION (SEE NOTE 2) Lot 18 Lot 19 LEVEL SPREADER WITH BIOSWALE MATERIAL PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C4.00_GRADING & EROSION.DWG 2/11/2014 8:00:36 AM SME OVERALL GRADING & EROSION CONTROL PLAN C4.00 N/A 30' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 30' 60' SCALE: 1" = 30' 15' LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR STORM SEWER STORM INLET RETAINING WALL NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. REFER TO SHEETS C4.01-C4.04 FOR DETAILED GRADING PLANS. 4. PERMANENT REINFORCEMENT MATS (TRM) SHALL BE NORTH AMERICAN GREEN VMAX SC250 OR APPROVED EQUAL. TEMPORARY EROSION CONTROL BLANKETS (ECB) SHALL BE NORTH AMERICAN GREEN ERONET S75 OR APPROVED EQUAL. 5. REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 6. LANDSCAPING WITHIN THE HABITAT BUFFER ZONE SHALL CONSIST OF NATIVE MATERIALS. REFER TO THE LANDSCAPE PLANS. 7. VEGETATIVE SWALES, THE BIOSWALE, AND THE SNOUT BMP SHALL BE MAINTAINED BY THE PROPERTY OWNER OR HOA AND FOLLOW APPLICABLE STANDARD OPERATING PROCEDURES AS SHOWN IN DRAINAGE REPORT FOR BELLA VIRA SUBDIVISION FILING TWO. SILT FENCE VEHICLE TRACKING CONTROL PAD RIPRAP PAD WATTLE DIKE CONCRETE WASHOUT AREA - FINAL LOCATION TO BE DETERMINED BY CONTRACTOR SLOPE PROTECTION (SEE EROSION CONTROL NOTE 5) DROP INLET PROTECTION TURF REINFORCEMENT MAT (SEE NOTE 4) BIOSWALE ROCK SOCK EROSION CONTROL BLANKETS (SEE NOTE 10) 1. THE SITE WILL BE LANDSCAPED TO FINAL STABILIZATION. SEE FINAL LANDSCAPE PLAN FOR DETAILS. 2. REFER TO SHEET C-0.1 FOR STANDARD EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES. 3. EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 4. IN ADDITION TO THE EROSION CONTROL MEASURES SHOWN ON THIS DRAWING, THE CONTRACTOR SHALL COORDINATE WITH, AND UPDATE AS REQUIRED, THE STORMWATER MANAGEMENT PLAN (SWMP) FOR THIS PROJECT. 5. CONTRACTOR TO TERRACE SLOPES USING A "TRACKED" VEHICLE, RUN PERPENDICULAR TO SLOPE TO INHIBIT RILL/GULLEY EROSION, CONTRACTOR MAY USE OTHER WINDROW-TYPE METHODS AS APPROVED BY ENGINEER. TYPICAL ALL SLOPES, REPEAT AS NECESSARY UNTIL LANDSCAPING IS INSTALLED. 6. ANY AREAS USED FOR STOCKPILING AND/OR STAGING SHOULD ALSO HAVE SEDIMENT AND EROSION CONTROL MEASURES AS NECESSARY. THESE AREAS SHOULD BE LOCATED AT LEAST 100' AWAY FROM DRAINAGE WAYS. THE SWMP SHOULD BE UPDATED TO SHOW THESE AREAS AND SEDIMENT AND EROSION CONTROL ITEMS. THE ITEMS MAY INCLUDE BUT ARE NOT LIMITED TO VEHICLE TRACKING CONTROL, SILT FENCE, CONSTRUCTION FENCE, CONCRETE WASHOUT, AND SEDIMENT TRAP. 7. SOIL AMENDMENTS SHALL BE INCORPORATED IN ALL LANDSCAPE AREAS TO A DEPTH OF 6" AT A RATE OF 3 CUBIC YARDS PER 1000 SQUARE FEET OF AREA -OR- 4" OF LOOSE TOPSOIL IMPORTED ONTO THE SITE OVER 4" OF LOOSENED SUBGRADE SOILS. REFER TO CITY OF FORT COLLINS CODE SECTIONS 12-130 THROUGH 12-132. 8. TEMPORARY SEEDING SHALL BE UTILIZED IN THE EVENT THAT A GRADED AREA IS EXPOSED LONGER THAN 30 DAYS. THE SITE SHALL BE SEEDED WITH 100% SMOOTH BROME AT A MINIMUM APPLICATION RATE OF 30 PLS/LBS/ACRE. 9. A COMMERCIAL FERTILIZER WITH THE FOLLOWING SPECS SHALL BE USED: PROVIDE 4.5' SUMP AND INSTALL 24F SNOUT WITH BIOSKIRT (SEE NOTE 9 & DETAILS) PROPOSED 8" SANITARY STA.=10+69.52 INV.= 5121.49 2.6' PROPOSED GRADE EXISTING GROUND PROPOSED 8" WATER STA.=10+82.97 T.O.P.= 5120.79 12" MIN. CONCRETE ENCASE STORM SEWER JOINTS 10-FEET ON EITHER SIDE OF WATER CROSSING (SEE DETAILS) CONCRETE HEADWALL (SEE STRUCTURAL DETAILS) RIPRAP PAD 100-YEAR HGL PROPOSED ELEC. STA.=10+20.60 T.O.P.= 5121.2± PROPOSED ELEC. STA.=10+93.01 T.O.P.= 5123.3± APPROX. LOCATION OF EXIST. 36" WATER STA.=9+77.59 T.O.P.= 5111.3± EXISTING 12" AND 8" HDPE PIPES (SEE NOTE 10) 4.5' MIN. LEVEL SPREADER (SEE DETAILS) PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP 2/11/2014 8:41:42 AM SME STORM SEWER PLAN AND PROFILE C3.02 3' 30' 0 30' 60' SCALE: 1" = 30' 15' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. ALL STORM SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 3. ALL PIPE LENGTHS ARE FROM CENTER TO CENTER OF ADJACENT STRUCTURES UNLESS OTHERWISE NOTED. 4. STORM SEWER MAINS AND ROOF LEADERS SHOWN ON THESE DRAWINGS AS HIGH DENSITY POLYETHYLENE (HDPE) SHALL BE WATERTIGHT ADS-N12 OR APPROVED EQUAL. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 6. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS OF DOWNSPOUTS WITH ARCHITECTURAL PLANS. 7. CONTRACTOR SHALL CONNECT TO DOWNSPOUTS AT THE LOCATIONS INDICATED WITH A 4-INCH HDPE PIPE. CONTRACTOR SHALL BURY THE 4" HDPE ROOF LEADER A MINIMUM OF 30-INCHES DEEP, RUN THE LEADER AT A MINIMUM OF 2% SLOPE AND MAKE THE CONNECTIONS TO THE HDPE STORM SEWER. 8. ROOF DRAINS TO BE CONNECTED DIRECTLY TO PROPOSED HDPE STORM SEWER SHALL BE CONNECTED USING MANUFACTURED TEES. 9. INLET 1-2 SHALL BE INSTALLED WITH A 24F SNOUT BMP AND BIOSKIRT. SEE DETAILS FOR MORE INFORMATION. 10.CONTRACTOR SHALL FIELD VERIFY LOCATION OF EXISTING 12" AND 8" HDPE PIPES AS SHOWN PRIOR TO CONSTRUCTION AND SHALL CONCRETE ENCASE EACH PIPE 10-FEET ON EITHER SIDE OF SWALE CROSSING. 11.ALL SITE STORM SEWER AS SHOWN ON THESE DRAWINGS IS PRIVATE. 12.REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 13.LANDSCAPING WITHIN THE HABITAT BUFFER ZONE SHALL CONSIST OF NATIVE MATERIALS. REFER TO THE LANDSCAPE PLANS. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET STORM DRAIN M.H. WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE STORM DRAIN INLET MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. INLET SCHEDULE INLET ID TYPE 1-2 10' TYPE R (SEE DETAILS) 1-4 & 1-7 15" NYLOPLAST DRAIN BASIN (OR APPROVED EQUAL (SEE DETAILS) ROOF DRAIN KEY: 4" ROOF DRAIN (SEE NOTES 6-8) RIM = 5128.58 DEPTH = 8.33' INV. IN = 5120.35 (S) INV. OUT = 5120.25 (W) STA: 10+00.00 REMOVE PLUG & CONNECT TO EXISTING STUB INV.= 5120.47' CONTRACTOR TO CONFIRM ELEVATION & CONTACT ENGINEER OF ANY DISCREPANCIES EX. STUB 2.6' 9+50 10+00 11+00 12+00 13+00 14+00 15+75 15+00 STA:9+50.00 N=1452871.61 E=3102074.41 BEGIN SANITARY SEWER ALIGNMENT EX. MH STA:9+70.37 N=1452852.37 E=3102081.07 STA:10+00.00 REMOVE PLUG & CONNECT TO EXISTING SANITARY SEWER STUB N=1452824.37 E=3102090.76 CONTRACTOR TO VERIFY LOCATION & CONTACT ENGINEERS OF ANY DISCREPANCIES SEE NOTE #2 MH A-1 STA:10+51.93 N=1452775.29 E=3102107.76 S19°05'50.97"E 51.93' S47°23'03.92"E 185.52' MH A-2 STA:12+37.46 N=1452649.68 E=3102244.29 152° 138° S89°43'05.73"E 119.76' MH A-3 STA:13+57.21 N=1452649.09 E=3102364.04 135° N45°16'54.27"E 35.80' MH A-4 STA:13+93.01 N=1452674.27 E=3102389.48 135° N0°16'43.66"E 57.81' MH A-5 STA:14+50.82 N=1452732.09 E=3102389.76 167° N12°49'44.58"W 89.84' MH A-6 STA:15+40.66 N=1452819.69 E=3102369.81 STA:15+75.00 N=1452853.16 E=3102362.18 END SANITARY SEWER ALIGNMENT 10' WATERLINE EASEMENT 75' UNITED STATES EASEMENT LOT 25 LOT 24 LOT 23 LOT 22 LOT 1 LOT 2 LOT 3 LOT 7 LOT 6 LOT 5 LOT 4 LOT 12 LOT 8 LOT 11 LOT 13 LOT 15 LOT 14 LOT 16 LOT 17 LOT 10 LOT 9 BLOCK 1 LOT 21 LOT 20 BLOCK 1 LOT 18 LOT 19 SANITARY CLEANOUT (TYP.) 20' UTILITY EASEMENT SANITARY SERVICE TABLE BLOCK# -LOT# 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 1-10 STATION 15+35.66 15+19.51 14+61.13 14+41.20 13+98.63 13+90.06 13+57.21 13+40.21 13+25.72 12+63.68 OFFSET 26.60, R 27.71, R 24.32, R 21.21, R 15.21, R 32.95, R 45.03, R 36.09, R 31.10, R 33.10, R SANITARY SERVICE TABLE BLOCK# -LOT# 1-11 1-12 1-13 1-14 1-15 1-16 1-17 1-18 1-19 1-20 STATION 12+53.68 11+93.94 11+84.11 11+19.72 10+81.05 10+59.95 10+25.89 11+04.24 11+22.64 11+81.03 OFFSET 31.10, R 23.90, R 23.90, R 23.99, R 20.29, R 17.07, R 35.25, R -33.26, L -35.28, L -35.34, L SANITARY SERVICE TABLE BLOCK# -LOT# 1-21 1-22 1-23 1-24 1-25 STATION 11+96.94 14+22.13 14+38.20 15+09.52 15+29.52 OFFSET -34.35, L -37.00, L -35.00, L -35.79, L -42.06, L PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C3.01_SANITARY P&P.DWG 2/11/2014 8:08:32 AM SME SANITARY SEWER PLAN & PROFILE C3.01 3' 30' 0 30' 60' SCALE: 1" = 30' 15' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. SHOULD THE WATER LINE CROSS UNDER EITHER STORM DRAIN OR SANITARY SEWER, THE STORM OR SANITARY SHALL BE CONCRETE ENCASED FOR 10' ON EITHER SIDE OF THE CROSSING. 4. SANITARY SEWER AND SERVICES SHALL BE SDR-35 PVC. 5. REFER TO THE UTILITY PLAN (SHEET C3.00) FOR INFORMATION REGARDING WATERLINE CONSTRUCTION. 6. REFER TO THE STORM SEWER PLAN AND PROFILE (SHEET C3.02) FOR INFORMATION REGARDING STORM SEWER CONSTRUCTION. 7. SANITARY SERVICE TABLE INFORMATION IS TO CENTER OF CLEANOUT. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET STORM DRAIN M.H. WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE STORM DRAIN INLET MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. LIGHT POLE STORM SEWER CROSSING STORM SEWER INV.=5118.23 TOP WATER=5120.79 STORM SEWER (SEE STORM SEWER PLAN & PROFILE C3.02) 10' WATERLINE EASEMENT 75' UNITED STATES EASEMENT 4" UNDER DRAIN (SEE DETAILED GRADING PLAN) LIMITS OF DISTURBED AREA LOT 25 LOT 24 LOT 23 LOT 22 LOT 21 LOT 20 LOT 7 LOT 1 LOT 2 LOT 6 LOT 5 LOT 4 LOT 3 LOT 12 LOT 8 LOT 11 LOT 13 LOT 15 LOT 14 LOT 16 LOT 17 LOT 10 LOT 9 BLOCK 1 BLOCK 1 LOT 18 LOT 19 WATER CURB STOP (TYP.) 20' UTILITY EASEMENT HABITAT BUFFER (TYP.) EXISTING 12" HDPE DRAIN PIPE EXISTING 8" HDPE DRAIN PIPE REMOVE PLUG & CONNECT TO EXISTING SANITARY SEWER STUB (SEE SANITARY SEWER PLAN & PROFILE C3.01) TRACT C CITY REGIONAL DETENTION POND LEVEL SPREADER WITH BIOSWALE MATERIAL WATER SERVICE TABLE BLOCK# -LOT# 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 1-10 NORTHING 1452833.71 1452783.67 1452754.94 1452713.33 1452689.83 1452658.87 1452636.98 1452631.35 1452628.88 1452627.41 EASTING 3102381.22 3102399.83 3102398.64 3102403.00 3102402.89 3102394.68 3102388.07 3102360.12 3102322.45 3102286.04 WATER SERVICE TABLE BLOCK# -LOT# 1-11 1-12 1-13 1-14 1-15 1-16 1-17 1-18 1-19 1-20 NORTHING 1452633.90 1452658.93 1452683.58 1452705.32 1452734.15 1452770.69 1452807.70 1452775.55 1452734.70 1452724.82 EASTING 3102242.33 3102212.79 3102179.77 3102157.60 3102127.44 3102094.21 3102076.53 3102153.69 3102196.27 3102207.05 WATER SERVICE TABLE BLOCK# -LOT# 1-21 1-22 1-23 1-24 1-25 NORTHING 1452685.17 1452693.51 1452733.35 1452768.73 1452819.75 EASTING 3102240.96 3102366.24 3102365.35 3102353.54 3102345.05 PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C3.00_UTILITY PLAN.DWG 2/11/2014 8:02:14 AM SME UTILITY PLAN C3.00 N/A 20' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 4.5'. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. SHOULD THE WATER LINE CROSS UNDER EITHER STORM DRAIN OR SANITARY SEWER, THE STORM OR SANITARY SHALL BE CONCRETE ENCASED FOR 10' ON EITHER SIDE OF THE CROSSING. 5. REFER TO APPROVED SITE ELECTRICAL PLANS FOR ALL SITE LIGHTING AS SHOWN ON THIS DRAWING. 6. THE DRY UTILITIES ARE SHOWN FOR LOCATION AND INTENT ONLY. THE CONTRACTOR SHALL COORDINATE THE FINAL DESIGN OF THE DRY UTILITIES WITH THE UTILITY PROVIDERS. 7. WATER MAINS SHALL BE AWWA C-900 PVC. WATER SERVICES SHALL BE 3/4" TYPE K COPPER. 8. WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 9. WATER SERVICE TABLE INFORMATION IS TO CENTER OF CURB STOP. 10.WATER METERS TO BE INTERNAL TO EACH UNIT. 11.REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 12.LANDSCAPING WITHIN THE HABITAT BUFFER ZONE SHALL CONSIST OF NATIVE MATERIALS. REFER TO THE LANDSCAPE PLANS. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET STORM DRAIN M.H. WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE STORM DRAIN INLET MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. GAS LINE ELECTRIC LINE LIGHT POLE 0 20' 40' SCALE: 1" = 20' 10' MAILBOX PAD 2- CURB CUT & SIDEWALK CHASE 2- CURB CUT & SIDEWALK CHASE DRIVE-OVER CURB & GUTTER EDGE OF ACCESS, PEDESTRIAN ACCESS, UTILITY AND DRAINAGE EASEMENT (TYP.) LOT LINE (TYP.) LOT LINE (TYP.) LOT LINE (TYP.) BIOSWALE WITH UNDERDRAIN (SEE DETAILED GRADING PLAN) PROPERTY BOUNDARY (TYP.) PROPERTY BOUNDARY (TYP.) EDGE OF ACCESS, PEDESTRIAN ACCESS, UTILITY AND DRAINAGE EASEMENT (TYP.) WEST ELIZABETH IMPROVEMENTS CURRENTLY UNDER CONSTRUCTION (SEE NOTE 2) OVERLAND TRAIL WIDENING IMPROVEMENTS CURRENTLY UNDER CONSTRUCTION (SEE NOTE 2) EDGE OF ACCESS, PEDESTRIAN ACCESS, UTILITY AND DRAINAGE EASEMENT (TYP.) REAR PATIO OR DECK (TYP.) (SEE ARCH. PLANS) LANDSCAPE WALL (SEE NOTE 4) LANDSCAPE WALL (SEE NOTE 4) LANDSCAPE WALL (SEE NOTE 4) LANDSCAPE WALL (SEE NOTE 4) LANDSCAPE WALL (SEE NOTE 4) 4 INLET (SEE SHEET C3.02) SEE SHEET C5.0 FOR STREET PLAN & PROFILE 13.65' 15.02' 15.89' 28.54' 28.54' 43.22' 14.94' 35.75' 35.84' 36.12' 67.59' EXISTING 20' E.A.E. 16' EP-EP 10' EXISTING 20' UTILITY ESMT. EXISTING 10' WATERLINE ESMT. 5' EXIST. 15' U.E. EXISTING 75' UNITED STATES ESMT. 107.5' PUBLIC RIGHT-OF-WAY EXIST. 9' UTILITY ESMT. EXIST. 9' UTIL. ESMT. 51' PUBLIC RIGHT-OF-WAY 12' CONCRETE PAN 7.17' 18' PKG TO EP 10' 10' 16' EP-EP R37' INLET (SEE SHEET C3.02) INLET (SEE SHEET C3.02) 3.75' SIDEWALK 3.75' SIDEWALK 3.75' SIDEWALK 3.75' SIDEWALK DIRVE-OVER CURB & GUTTER DIRVE-OVER CURB & GUTTER VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER EXIST. 20' E.A.E T T T T T T T T T T T T T T T T 4 4 4 4 4 4 HEADWALL (SEE STRUCTURAL PLANS) T T LANDSCAPE WALL (SEE NOTE 4) BUILDING 4 BUILDING 3 BUILDING 2 BUILDING 1 BUILDING 5 BUILDING 6 BLOCK 1 BLOCK 1 (ADA UNIT) (ADA UNIT) (ADA UNIT) (ADA UNIT) Lot 18 Lot 19 HABITAT BUFFER (TYP.) PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C2.00_HORIZONTAL CONTROL PLA 2/11/2014 8:41:32 AM SME HORIZONTAL CONTROL AND SIGNING & STRIPING PLAN C2.00 N/A 20' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 1. FOR BUILDING LAYOUT REFERENCE ARCHITECTURAL PLANS. LAYOUT AND DIMENSION INFORMATION SHOWN REPRESENTS OUTSIDE FACE OF WALL AND IS SHOWN FOR INFORMATION ONLY. 2. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 3. NOTE THAT SIDEWALKS ALONG OVERLAND TRAIL AND WEST ELIZABETH STREET ADJACENT TO THE SITE ARE BEING INSTALLED WITH PHASE I OF BELLA VIRA SUBDIVISION BY OTHERS. 4. ALL DIMENSIONS AND LINE AND CURVE INFORMATION ARE MEASURED TO CURB FLOW LINE OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 5. CONTRACTOR SHALL REFER TO AND COORDINATE WITH THE APPROVED LANDSCAPE DRAWINGS FOR ALL LANDSCAPE AND SITE FEATURES SUCH AS LANDSCAPE WALLS, SEEDING/SOD, LANDSCAPE ROCK AND MULCH, ETC. 6. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 7. CONCRETE SIDEWALKS ADJACENT TO BELLA VITA WAY AND SABATINO WAY SHALL BE 6-INCH MINIMUM THICKNESS OR AS REQUIRED PER RECOMMENDATIONS FROM THE GEOTECHNICAL ENGINEER TO SUPPORT A 40-TON VEHICLE. 8. ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. 9. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. 10. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. 11. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. 12. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. 13. REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 14. LANDSCAPING WITHIN THE HABITAT BUFFER ZONE SHALL CONSIST OF NATIVE MATERIALS. REFER TO THE LANDSCAPE PLANS. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES 1 "STOP" SIGN (R1-1) 2 "NO PARKING-FIRE LANE" SIGN 3 4" SOLID WHITE LINE CONCRETE PAVEMENT OR SIDEWALK ASPHALT PAVEMENT CURB & GUTTER CURB & GUTTER TRANSITION T 4 PAINT CURB RED REAR PATIO OR DECK (SEE ARCH. PLANS) 0 20' 40' SCALE: 1" = 20' 10' OVERHEAD ELECTRIC EXISTING 42" WATERLINE EXISTING 20" WATERLINE EXISTING 60" WATERLINE EXISTING ELECTRIC VAULTS EXISTING 20' E.A.E. APPROXIMATE LIMITS OF DISTURBANCE (TYP.) / / / / / / / / / / / / / / / / / / / / / / / / / / / / 15' PLEASANT VALLEY AND LAKE CANAL ESMT. PROPERTY BOUNDARY (TYP.) HABITAT BUFFER (TYP.) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ABANDON/REMOVE EXISTING WATER SERVICE (SEE NOTE 4) PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com NONE KEVIN D:\DROPBOX\PROJECTS\U13012 BELLA VIRA\CADD\CP C1.00_EXISTING INFORMATION.DW 2/11/2014 8:41:29 AM SME EXISTING INFORMATION PLAN C1.00 N/A 30' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 30' 60' SCALE: 1" = 30' 15' 1. EXISTING INFORMATION AS SHOWN ON THIS PLAN IS PER DESIGN INFORMATION PROVIDED BY JIM SELL DESIGN AS SHOWN IN THE PHASE 1 CONSTRUCTION PLANS ENTITLED "BELLA VIRA SUBDIVISION" AND DATED DECEMBER 7, 2007. AT THE TIME OF THIS SUBMITTAL, CONSTRUCTION OF THE PHASE 1 BELLA VIRA IMPROVEMENTS IS NOT YET COMPLETE. CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AT ALL INTERFACES WITH PHASE 1 IMPROVEMENTS PRIOR TO THE COMMENCEMENT OF FILING 2 CONSTRUCTION. 2. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 3. REFER TO SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE HABITAT BUFFER ZONE. 4. THE LOCATION OF THE EXISTING WATER SERVICE AS SHOWN ON THIS DRAWING IS APPROXIMATE. THE CONTRACTOR SHALL HAVE THE SERVICE LOCATED AND SHALL REMOVE/ABANDON THE SERVICE PER FORT COLLINS-LOVELAND WATER DISTRICT STANDARDS (LATEST EDITION.) LEGEND NOTES LOT LINES / R.O.W. EASEMENT LINES CENTERLINE MAPPING CURB AND GUTTER INTERMEDIATE CONTOUR INDEX CONTOUR EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. WATER VALVE FIRE HYDRANT LIGHT POLE WATER / SANITARY PLUG WATER METER WATER VAULT FENCE PROPERTY BOUNDARY engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the local entity engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the local entity, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All sanitary sewer, storm sewer, and water line construction, as well as power and other "dry" utility installations, shall conform to the local entity standards and specifications current at the date of approval of the plans by the local entity engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The developer shall be responsible for unknown underground utilities. 7. The developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the local entity prior to beginning construction. 10. The developer shall coordinate and cooperate with the local entity, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water until the developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 14. A state construction dewatering wastewater discharge permit is required if dewatering is required in order to install utilities or water is discharged into a storm sewer, channel, irrigation ditch or any waters of the united states. 15. The developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the storm water management plan, and the erosion control plan. 16. The local entity shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the local entity, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the storm water utility department. Certification shall be submitted to the storm water utility department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Storm Water Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the development agreement. 18. The local entity including but not limited to South Fort Collins Sanitation District and Fort Collins-Loveland Water District shall not be responsible for any damages or injuries sustained in this development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the local entity failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the final drainage and erosion control study shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the erosion control plan. All erosion control measures shall be maintained in good repair by the developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the local entity street inspector. 22. No work may commence within any improved or unimproved public right-of-way until a right-of-way permit or development construction permit is obtained, if applicable. 23. The developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The developer shall notify the local entity engineering inspector (Fort Collins - 221-6605) and the local entity erosion control inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the local entity engineer is not available after proper notice of construction activity has been provided, the developer may commence work in the engineers absence. However, the local entity reserves the right not to accept the improvement if subsequent testing reveals an improper installation 24. The developer shall be responsible for obtaining soils tests within the public right-of-way after right-of-way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the developer shall be responsible for a re-design of the subject pavement section or, the developer may use the local entity's default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed professional engineer. The final report shall be submitted to the inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the local entity engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the local entity inspector. The engineer or surveyor must certify in a letter to the local entity that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the local entity before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County floodplain resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as wild fire hazard areas shall be done in accordance with the construction criteria as established in the wild fire hazard area mitigation regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the local entity forester to schedule a site inspection for any tree removal requiring a permit. 30. The developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The developer shall submit a construction traffic control plan, in accordance with MUTCD, to the appropriate right-of-way authority. (local entity, county or state), for approval, prior to any construction activities within, or affecting, the right-of-way. The developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact local entity traffic operations department, who will temporarily remove or relocate the sign at no cost to the contractor; however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The developer is responsible for all costs for the initial installation of traffic signing and striping for the development related to the development's local street operations. In addition, the developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the local entity engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the local entity. 35. The developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the designer for clarification, and annotate the dimension on the as-built record drawings. 37. The developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the developer shall contact the designer and the local entity engineer immediately. 39. The developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the local entity's inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the local entity engineer. 40. The designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: CITY OF FORT COLLINS 22-97 ON A MANHOLE BASE NEAR THE WEST RIGHT OF WAY OF OVERLAND TRAIL AND WEST ELIZABETH ST. ELEVATION=5138.68 (CITY OF FORT COLLINS-NGVD 1929 DATUM UNADJUSTED) CITY OF FORT COLLINS 32-92 NORTHEAST CORNER OF LAKE ST. AND OVERLAND TRAIL, IN EAST HEADWALL BRIDGE OVER PLEASANT VALLEY AND LAKE CANAL. ELEVATION=5116.24 (CITY OF FORT COLLINS-NGVD 1929 DATUM UNADJUSTED) ASSUMING THE EAST LINE OF THE SOUTHEAST 1/4 OF SECTION 17, T.7N., R.69W., AS BEARING N00°16'54"E BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983/2007, A DISTANCE OF 2636.54 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first certificate of occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the local entity construction inspector before any cuts are made. Patching shall be done in accordance with the local entity street repair standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the local entity engineer and/or the local entity inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the local entity, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The local entity shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: none. 48. Approved variances are listed as follows: -None. 1. All street construction is subject to the General Notes on the Cover Sheet of these plans as well as the street improvements notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed engineer, must be submitted to the local entity engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the local entity engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the local entity engineer. 5. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, reconstruction and repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the local entity engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in MUTCD (including Colorado supplement) and as per the right-of-way work permit traffic control plan. 8. The developer is required to perform a gutter water flow test in the presence of the local entity inspector and prior to installation of asphalt. Gutters that hold more than inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. And a single axle weight of at least 18,000 lbs. With pneumatic tires inflated to not less than 90 P.S.I.G. "proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the local entity engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The local entity engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be performed in the presence of an inspector. 1. All signage and marking is subject to the General Notes on the Cover Sheet of these plans, as well as the traffic signing and marking construction notes listed here. 2. All symbols, including arrows, ONLY's, crosswalks, stop bars, etc. shall be preformed thermoplastic. 3. All signage shall be per local entity standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Preformed thermoplastic applications shall be as specified in these plans and/or these standards. 8. Epoxy applications shall be applied as specified in CDOT standard specifications for road and bridge construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer . All discrepancies identified during the field inspection must be corrected before the two year warranty period will begin. GENERAL AND CONSTRUCTION NOTES C0.01 CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com PROJECT TEAM PROJECT COORDINATES CITY OF FORT COLLINS 22-97 ON A MANHOLE BASE NEAR THE WEST RIGHT OF WAY OF OVERLAND TRAIL AND WEST ELIZABETH ST. ELEVATION=5138.68 (CITY OF FORT COLLINS-NGVD 1929 DATUM UNADJUSTED) CITY OF FORT COLLINS 32-92 NORTHEAST CORNER OF LAKE ST. AND OVERLAND TRAIL, IN EAST HEADWALL BRIDGE OVER PLEASANT VALLEY AND LAKE CANAL. ELEVATION=5116.24 (CITY OF FORT COLLINS-NGVD 1929 DATUM UNADJUSTED) ASSUMING THE EAST LINE OF THE SOUTHEAST 1/4 OF SECTION 17, T.7N., R.69W., AS BEARING N00°16'54"E BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983/2007, A DISTANCE OF 2636.54 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. 1. ALL PROJECT CONTROL LISTED HEREON IS PROVIDED AS A COURTESY. IT IS THE RESPONSIBILITY OF THE RECIPIENT TO VERIFY THE ACCURACY OF THE COORDINATES AND ELEVATIONS SHOWN PRIOR TO USING THEM FOR ANY PURPOSES. Water/Wastewater City of Fort Collins Utilities Roger Buffington (970) 221-6854 Stormwater City of Fort Collins Utilities Glen Schlueter (970) 221-6700 Power City of Fort Collins Light & Power Doug Martine (970) 224-6152 Natural Gas Xcel Energy Stephanie Rich (970) 225-7828 Telecom Centurylink Bill Johnson (970) 377-6401 Cable Comcast Don Kapperman (970) 567-0245 Note: All utility providers listed hereon is provided as a courtesy. It is the responsibility of the recipient to verify the accuracy and completeness of the information shown. UTILITY PROVIDERS PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BELLA VIRA TOWNHOMES INC. 02/12/2014 BELLA VIRA SUBDIVISION FILING TWO 26 U13012 PRELIMINARY PLANS NOT FOR CONSTRUCTION Civil Engineering & Consulting 1501 Academy Court, Suite 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com C0.00 COVER SHEET C0.01 GENERAL AND CONSTRUCTION NOTES PLAT (FOR REFERENCE ONLY) C1.00 EXISTING INFORMATION PLAN C2.00 HORIZONTAL CONTROL AND SIGNING & STRIPING PLAN C3.00 UTILITY PLAN C3.01 SANITARY SEWER PLAN & PROFILE C3.02 STORM SEWER PLAN & PROFILE C4.00 OVERALL GRADING AND EROSION CONTROL PLAN C4.01-C4.04 DETAILED GRADING PLANS C5.00 BELLA VITA WAY & SABATINO LANE CENTERLINE PLAN & PROFILE C6.00 DRAINAGE PLAN C7.00-C7.06 CONSTRUCTION DETAILS S1.00 STRUCTURAL ABBREVIATIONS, DETAIL REFERENCE KEY & LAPS S1.01 GENERAL STRUCTURAL NOTES S2.00 HEADWALL, WINGWALL PLAN & DETAILS SHEET INDEX CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R Mr. Terry W. Farrill, P.E., District Engineer Mr. Michael D. DiTullio, Manager Date Date All changes, addendum, additions, deletions and modifications to these drawings must be approved in writing, by the Fort Collins - Loveland Water District and the South Fort Collins Sanitation District.