Loading...
HomeMy WebLinkAboutSCOTT PLAZA - FDP - FDP140004 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSW. PLUM ST. SHIELDS ST. MULBERRY ST. TAFT HILL RD. ELIZABETH ST. W. PROSPECT RD. MOUNTAIN AVE. PROJECT SITE CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R CONTACT INFORMATION PROJECT TEAM: Ripley Design, Inc. Linda Ripley, ASLA, ULI, RLA 401 West Mountain Avenue Fort Collins, Colorado 80521 (970) 224-5828 Taylor Fitzpatrick Capital, LLC Jake Taylor 7825 E. Gelding Street, Suite 102 Scottsdale, AZ 85260 (888) 446-3344 GAS----------------- Xcel Energy----------------------------- Stephanie Rich (970) 225-7828 ELECTRIC-------- City of Fort Collins Light & Power -- Doug Martine (970) 224-6152 CABLE------------- Comcast----------------------------------- Don Kapperman (970) 567-0245 TELECOM.--------CenturyLink------------------------------- William Johnson (970) 490-7501 WATER------------ City of Fort Collins Utilities----------- Roger Buffington (970) 221-6700 WASTEWATER--City of Fort Collins Utilities----------- Roger Buffington (970) 221-6700 STORMWATER- City of Fort Collins Utilities----------- Glen Schlueter (970) 221-6700 FIBER OPTICS-- Colorado State University------------ Kurt Davis (970) 491-0187 UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. JANUARY 2014 SHEET INDEX UTILITY PLANS FOR A TRACT OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 15, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Terracon Consultants, Inc. Eric Bernhardt, PE 301 North Howes Street Fort Collins, Colorado 80521 (970) 484-0359 PHONE NUMBER Northern Engineering Services, Inc. Nick Haws, PE, LEED AP 200 South College Avenue, Suite 10 Fort Collins, Colorado 80524 (970) 221-4158 Northern Engineering Services, Inc. Gary Gilliland, PLS 200 South College Avenue, Suite 10 Fort Collins, Colorado 80524 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R C001 A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. X T T T T T T T T T T T T T T T T T T T T CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV X X X X X X X X X X X X X X X X 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS X X X X X X X X X X X E 8" SS 8" SS 8" SS 8" SS CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV G G G G X X X X X X X X X X X X X X X X X X E E X X X X X X X X X X X X X X X X X X X X X X X CAMBRIDGE HOUSE LLC 1113 W PLUM ST FORT COLLINS, CO 80521 COLLINS CAMPUS WEST LLC 1220 W ELIZABETH ST FORT COLLINS, CO 80521 TOWNSQUARE CONDOS 1209 W PLUM ST FORT COLLINS, CO 80521 RESIDENTIAL BUILDING OUTLINE (ABOVE) DECORATIVE CONCRETE RIBBONS (TYP.) EXISTING 24' PUBLIC ACCESS EASEMENT PROPOSED 30" VERTICAL CURB & GUTTER EXISTING CONCRETE PAN EXISTING VERTICAL CURB & GUTTER PROPOSED COLUMN (TYP.) PROPOSED BIKE RACK (TYP.) EXISTING CONCRETE PAN CONCRETE X T T T CTV CTV CTV X X X X X X X X X 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS X X X X X X X X 8" SS 8" SS 8" SS 8" SS CTV CTV CTV G G G G G G G G G G G G G G G G G G G G G G E E 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W W W W W W 6" W 6" W FO FO FO FO FO FO FO FO FO C301 LEGEND: G T ST NORTH E UD PROFILE SCALE: SUBDRAINS A & B These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R NOTES: INLET SCHEDULE INLET ID INLET TYPE SIZE (IN.) GRATE TYPE BASIN A1 WATER CONTROL 24 SOLID (H-20) BASIN A2 DRAIN BASIN 8 SOLID (H-20) BASIN B1 DRAIN BASIN 8 SOLID (H-20) BASIN B2 DRAIN BASIN 8 SOLID (H-20) **WATER CONTROL BASIN SHALL BE FITTED WITH OUTLET ORIFICE CAP ON NORTH SIDE OF DRAIN BASIN. ORIFICE OPENING SHALL BE 5.75" DIAMETER X X X X X X X X X X X X X X UD UD UD UD UD UD UD UD UD UD UD UD UD UD X X X X X X X X X X X X X X X X X X E E X X X X X X X X X E E E E E E E E E E E E E E E E E G E/TV E/TV E/TV EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING CAMBRIDGE HOUSE LLC 1113 W PLUM ST FORT COLLINS, T T T CTV CTV CTV X X X X X X X X X 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS X X CTV CTV CTV G G G G G G G G G G G G G G G G 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W W W W W 6" W 6" W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO T T T T T T T T T T T T T X X X X T T T T These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R C500 100 WATER MAIN BEDDING REQUIREMENTS 101 STANDARD CONCRETE THRUST BLOCKS 107 TYPICAL POINT OF CONNECTION 102 TYPICAL WATER SERVICE 104 105 106 103 STANDARD EXTERIOR SETTING FOR 3/4" AND 1" WATER METERS ALTERNATE SETTING FOR 3" & 4" WATER METERS ALTERNATE SETTING FOR 3" & 4" WATER METERS ALTERNATE SETTING FOR 3" & 4" WATER METERS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R C501 200 201 PLAN VIEW CROSS VIEW 45 ELBOW SERVICE WYE 8 IN. PVC SEWER PIPE COMPACTED GRANULAR MATERIAL AIR-TIGHT PLUG WITH 4 IN. X 4 IN. MARKER UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR LEAN CONCRETE PVC SEWER PIPE NOTE: WYE CONNECTION NOT ALLOWED ON VCP LEAN CONCRETE o 20 MIN. o 45 MAX. o TRENCH UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR 4 IN. X 4 IN. MARKER AIR-TIGHT PLUG SERVICE WYE DETAIL WW-9 PRIVATE SANITARY SEWER CLEANOUT 206 TRAFFIC/PAVED AREAS LANDSCAPED AREAS 202 205 STANDARD SEWER SERVICE TRAFFIC RATED CLEANOUT FLOW DIRECTION TRAFFIC RATED CLEANOUT WW-15 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R C502 PAVEMENT SECTIONS (PRIVATE AREAS OUTSIDE ROW) PERMEABLE PAVER SECTION (ABUTTING EDGE RESTRAINT) THICKENED CONCRETE EDGE DRY WELL DETAIL DIMENSIONS FOR SLOTTED PVC PIPE SCREEN SLOT TABLE A B C D E F PIPE SIZE ROWS OF SLOTS SLOT LENGTH MAXIMUM SLOT WIDTH APPROX. SLOT/ROW PER FOOT APPROX. SLOT SPACING OPEN AREA PER FOOT 6" 3 (MIN.) - 6 (MAX.) 1.38"-2.35" 0.032" 14 1/2"-3/4" 1.98-3.15 SQ. IN. WQ CONTROL BASIN PRIVATE UNDERDRAIN CLEANOUT EXTEND MIN. 6" INTO SUBGRADE 8" 12" MIN WIDTH GUIDELINE 8" MIN THICKNESS GUIDELINE VARIES (REFER TO STORM DRAIN PLAN) INTEGRATED DUCTILE IRON FRAME & SOLID GRATE TO MATCH BASIN O.D. These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R C503 400 CURB AND GUTTER 401 CURB AND GUTTER / SIDEWALK 402 6 " 2"R. 2" 6" 6" 12" 1 1/2"R. 2'-6" 6" 4 1/2" 30" 9" R 0.5" 4.5" 18" 3.63" 21.75" R 0.13" 7" 2" 3.75" 12" ROLL-OVER VERTICAL (LOVELAND) Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) 7 3/8" (L) 1 3/8" 17" 6" 3 3/8" 14" FL R 16" S UD UD UD UD UD UD UD UD UD UD UD UD UD UD X X X X X X X X X X X X X X X X X X E E X X X X X X X X X G X X X X X X X X X X X X X X EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING CAMBRIDGE HOUSE LLC 1113 W PLUM ST FORT COLLINS, CO 80521 TOWNSQUARE CONDOS 1209 W PLUM ST FORT COLLINS, CO 80521 EXISTING BUILDING EXISTING WALL EXISTING RETAINING WALL EXISTING RETAINING WALL EXISTING WALL UD UD UD UD UD UD UD UD UD UD UD UD UD UD X X X X X X X X X X X X X X X X X X X X X X X X X X X EXISTING BUILDING TOWNSQUARE CONDOS 1209 W PLUM ST FORT COLLINS, CO 80521 EXISTING BUILDING COLLINS CAMPUS WEST LLC 1220 W ELIZABETH ST FORT COLLINS, CO 80521 EXISTING ASPHALT PARKING LOT PLUM STREET (ROW VARIES) TRASH EXISTING WALL EXISTING RETAINING WALL EXISTING RETAINING WALL EXISTING WALL EXISTING RETAINING WALL PROPOSED STORM OUTFALL EXISTING CONCRETE PAN PROPOSED STORM DRAIN (BY OTHERS) ROOF OUTLINE (ABOVE) ROOF OUTLINE (ABOVE) PROPOSED UNDERDRAIN PROPOSED These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com C602 FLOW 3'-4' WATTLE "A" WATTLE "B" 4"-6" ABOVE WATTLE AFTER BAILING WIRE OR NYLON ROPE IS ATTACHED. STAKES NEED TO BE TAMPED UNTIL WIRE/ROPE IS SNUG WITH WATTLE. 1. WHEN USING STRAW WATTLE, THE STRAW WATTLE MUST HAVE A WEIGHTED CORE. SF CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R 01 SILT FENCE 03 CURB INLET PROTECTION 02 DROP INLET PROTECTION 04 WATTLE INSTALLATION 05 VEHICLE TRACKING PAD 05 CONCRETE WASHOUT AREA UNDERDRAIN ROOF OUTLINE (ABOVE) PROPOSED PROPOSED DRY WELL UNDERDRAIN RS RS RS RS RW RW RW RS IP SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF S F SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF RW VTC IP PROPOSED UNDERDRAIN C601 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com NORTH TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION CONSTRUCTION PHASE (DESCRIPTION) PHASE I (GRADING) PHASE II (INFRASTRUCTURE) PHASE III (VERTICAL CONSTRUCITON) PHASE IV (PERMANENT BMP'S) Grading (Include Offsite) Overlot Pipeline Installation Stormwater Concrete Installation Site Walls Building Structure Miscellaneous Hardscape Amenities BEST MANAGEMENT PRACTICES Temporary Inlet Protection (IP) Vehicle Tracking Control (VTC) Flow Barriers (Bales, Wattles, Rock Socks, etc.) (WD) Concrete Washout Area (CWA) Preventative Maintenance Activities/Meetings/etc. Silt Fence (SF) Permanent Mulching/Sealant Permanent Seed Planting Sewer Service Water Service Curb and Gutter EROSION CONTROL NOTES: BENCHMARK/BASIS OF BEARING LEGEND: ST SF NOTE: ALL BMP'S SHOWN ON THIS PLAN ARE GRAPHIC REPRESENTATIONS ONLY. FINAL DETERMINATION OF SIZE AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND DOCUMENTED ON THE DYNAMIC SITE PLAN. FIELD SURVEY BY: GENERAL NOTES: EXISTING RETAINING WALL COLLINS CAMPUS WEST LLC 1220 W ELIZABETH ST FORT COLLINS, CO 80521 PROPOSED STORM OUTFALL EXISTING CONCRETE PAN EXISTING ASPHALT PARKING LOT PROPOSED STORM DRAIN (BY OTHERS) PERMEABLE PAVER DETENTION DETENTION VOLUME=5086 CU.FT. (40% VOID RATIO) FORMER SCOTT AVE. (VACATED 25' ROW) PLUM STREET (ROW VARIES) TRASH ROOF OUTLINE (ABOVE) RESIDENTIAL ROOF OUTLINE (ABOVE) PROPOSED UNDERDRAIN PROPOSED UNDERDRAIN ROOF OUTLINE (ABOVE) PROPOSED DRY WELL 1 4 2 3 5 5 3 1 2 4 PROPOSED UNDERDRAIN These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com C600 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R NORTH LEGEND: A BENCHMARK BENCHMARK #1: City of Fort Collins Benchmark 19-97 At the southeast corner of West Elizabeth and Shields Street, on a concrete traffic signal base. Elevation=5022.56 BENCHMARK #2: City of Fort Collins Benchmark 20-97 At the southwest corner of West Elizabeth and Constitution Avenue, on a concrete traffic signal base. Elevation=5046.97 NOTES: FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION A Basin Area (acres) Treatment Type LID ? Percent 1 0.66 Permeable Pavers yes 56% 2 0.03 none yes 3% 3 0.24 Permeable Pavers yes 20% 4 0.02 Permeable Pavers yes 2% 5 0.23 Permeable Pavers/Grass Buffer yes 19% Totals 1.18 - - 100% UD LID SUMMARY TABLES: Pavement1 Area2 (sq.ft.) LID ? Percent Traditional Concrete/Asphalt 5,233 no 34% Permeable Pavers 9,959 yes 66% Totals 15,192 - 100% 1. Represents "new/additional" pavement beyond the existing condition. 2. Only pavement areas exposed to surface rainwater are included. R 16" DRIVE-OVER CURB, GUTTER AND DETACHED SIDEWALK 31" See Drawing 1601 10 3/4"(L) R 16" DRIVE-OVER CURB, GUTTER AND ATTACHED SIDEWALK 18" 18" 3 3/8" 1 3/8" 6" R 16" FL 14" 6" 17" 1 1/2" 5' (L) 8 5/8" (F.C.) 7 1/4" F.C. 12" (F.C.) Slope to curb 1/4"/Ft. 1' min. (F.C.) 48:1 min. 4:1 max. Excavation Fill 1' min. 2' min. 1/4"/Ft. CURB & GUTTER IN A CUT OR FILL 6" 3'-9" (F.C.) For Thickness 2' min. (L) 406 TRENCH DETAIL 12" (Water & Sewer) If this section is less than 4' of existing asphalt/concrete, it must be removed and replaced. Edge of Pavement or Lip of Existing Gutter Compacted Lifts of Suitable Materials Pavement Thickness Varies Varies 1" (min.) (See Note 9 below for Storm.) 4" (min.) 6" (max.) Trench Width Varies 2' (min.) Bedding Material Undisturbed Soil Utility Conduit New Asphalt/Concrete Clean Road Base Existing Road Base 6" Full Depth Asphalt or X/Y Composite Section NOTES: 1. All trenches shall be backfilled in accordance with the above detail unless otherwise specified by the Local Entity Engineer. 2. Prior to placement of asphalt/concrete, pavement edge shall be saw cut to a clean, vertical, and straight edge. 3. Where the surrounding soils are non-expansive, a sand/cement slurry (1 sack mix) may be substituted for backfill material. 4. Trench width shall not be more than 16" nor less than 12" wider than the outside diameter of the pipe. 5. Use a #4 rebar at centers along the perimeter of concrete replacement sections. 6. Refer to Chapter 22, Materials & Construction Specifications for compaction and testing requirements. 7. In unimproved areas, all disturbed areas shall be regraded, seeded & mulched. 8. In concrete roadways, a minimum of one entire concrete panel must be replaced. 9. Bedding material depth when installing storm sewer shall be up to spring line, except in areas of unsuitable backfill; then, bedding material shall be placed to a level 12" above pipe. 405 SIDEWALK DETAIL ATTACHED SIDEWALK DETAIL Slope sidewalk to curb 1/4" per foot. NOTE: Construct sidewalk with joints at 10' intervals R 1/8" WEAKENED PLANE JOINT EXPANSION JOINT R1/4" and aligned with scoring on curb. INSTALL IN LOCATIONS SPECIFIED IN CHAPTER 22 1/2" 1/4" 1/4 SLAB THICKNESS 1/4" DETACHED SIDEWALK DETAIL Variable Slope sidewalk to curb 1/4" per foot. 2' min. 404 STANDARD SIDEWALK Sidewalk Driveway DRIVEWAY SIDEWALK SECTION A-A NOTE: 1. Sidewalk grade shall remain consistent across driveway 3. This detail applies to Residential & Commercial driveways. Detached Sidewalk Attached Sidewalk DETACHED ATTACHED All Sidewalk Thickness Shall Be 6" minimum. SIDEWALK ONE IN EVERY EIGHT ACCESSIBLE SPACES, BUT NOT LESS THAN ONE, SHALL BE VAN ACCESSIBLE. ONE SIGN PER SPACE REQUIRED REQUIRED PER SPACE ONE SIGN REQUIRED PER SPACE ONE SIGN CAR ACCESSIBLE VAN ACCESSIBLE "UNIVERSAL DESIGN" CAR & VAN ACCESSIBLE OR A "UNIVERSAL" PARKING SPACE DESIGN MAY BE USED. THIS DESIGN IS USED TO ACCOMMODATE CAR & VAN ACCESSIBLE PARKING SPACES, WHICH ELIMINATES THE NEED FOR TWO SIGN TYPES. R7-8 R7-8 HANDICAP PARKING 403 TRUNCATED DOME WARNING FOR ACCESS RAMPS 407 PREFABRICATED WHEEL STOP NOTES: 1 - GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS SEE DRAWING NO. 7001-110-065 4 - PERFORATIONS SHOULD NOT BE ON OR WITHIN 1" OF ADAPTERS. 5 - HOLES SHOULD BE STAGGERED EVERY OTHER ROW, AS SHOWN. 0,1ƒ6(3$5$7,21%(7:((1+2/(6 0$;+2/(63(552: 2" MIN ‘0$; SIDE VIEW HOLE SIZE & LOCATION NTS ENLARGED TO SHOW DETAIL 6" THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. TOP 10" TO BE SOLID, WITHOUT PERFORATIONS 10" SOLID TOP NO PERFORATIONS WITHIN 1" OF ADAPTORS OPEN BOTTOM (NO BOTTOM CAP) 6" FLASHBOARDS VARIABLE INVERT HEIGHTS AVAILABLE (7' MAX STRUCTURE HT) DETAIL A DETAIL A EDPM O-RING SEAL DETAIL B ANODIZED ALUMINUM CHANNEL EDPM O-RING SEAL DETAIL B WATER FLOW STAINLESS STEEL LIFTING HOOKS PERMANENT 3" PLATE UP TO FLOW LINE NOTES: 1. REFER TO DETAIL 7001-110-298 FOR INSTALLATION GUIDELINES. 2. DIMENSIONS ARE FOR REFERENCE ONLY. 3. FLASHBOARDS SHALL BE PVC. 4. ALL RIVETS SHALL BE STAINLESS STEEL. 5. FLASHBOARD CHANNEL SHALL BE ANODIZED ALUMINUM. 6. FLASHBOARDS SHALL BE LUBRICATED UPON REMOVAL. WATER FLOW TOP VIEW AS NOTED VARIOUS TYPES OF INLET AND OUTLET ADAPTERS AVAILABLE UP TO 15" DIAMETER 24" NYLOPLAST WATER CONTROL STRUCTURE DWG SIZE A SCALE NTS SHEET 1 OF 1 DWG NO. 7008-110-004 REV B 24 IN NYLOPLAST INLINE WATER CONTROL STRUCTURE TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 4-1-13 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWN BY JJC NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 4-1-13 JJC 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com Š ‹2013 NYLOPLAST PROVIDE OUTLET ORIFICE CAP (5.75" DIAMETER OPENING SOLID GRATE ROOFDRAIN DOWNSPOUT DISCHARGE BASIN 8" 12" MIN WIDTH GUIDELINE 8" MIN THICKNESS GUIDELINE VARIES (REFER TO STORM DRAIN PLAN) INTEGRATED DUCTILE IRON FRAME & SOLID GRATE TO MATCH BASIN O.D. NOTES: 1 - GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS SEE DRAWING NO. 7001-110-065 4 - PERFORATIONS SHOULD NOT BE ON OR WITHIN 1" OF ADAPTERS. 5 - HOLES SHOULD BE STAGGERED EVERY OTHER ROW, AS SHOWN. 0,1ƒ6(3$5$7,21%(7:((1+2/(6 0$;+2/(63(552: 2" MIN ‘0$; SIDE VIEW HOLE SIZE & LOCATION NTS ENLARGED TO SHOW DETAIL 6" THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. TOP 10" TO BE SOLID, WITHOUT PERFORATIONS 6" SOLID BOTTOM NO PERFORATIONS WITHIN 1" OF ADAPTORS BOTTOM 6" TO BE SOLID, WITHOUT PERFORATIONS (BOTTOM CAP TO BE FLUSH WITH SUBGRADE) 4" MIN ON 8" - 24" 6" MIN ON 30" A TO PREVENT BLOCKAGE OF PERFORATIONS, BASIN SHOULD BE WRAPPED IN AN ENGINEER APPROVED GEO-TEXTILE FABRIC DWG SIZE A SCALE SHEET 1 OF 1 DWG NO. 7001-110-181 REV B 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 8 IN - 30 IN PERFORATED DRAIN BASIN WITH STANDARD GRATE QUICK SPEC INSTALLATION DETAIL TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 2-14-06 DRAWN BY EBC 2-14-06 CJA 1:40 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 1 VARIABLE INVERT HEIGHTS AVAILABLE (ACCORDING TO PLANS/TAKE OFF) USE CAP REDUCER AND DOME GRATE 1 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS SEE DRAWING NO. 7001-110-065 2 - PERFORATIONS SHOULD NOT BE ON OR WITHIN 1" OF ANY EDGE OR FITTING. 3 - HOLES SHOULD BE STAGGERED EVERY OTHER ROW, AS SHOWN. 4 - GRATES SHALL MEET H-10 LOAD RATING FOR 12" - 24" PED 5 - GRATES SHALL MEET H-20 LOAD RATING FOR 30" PED & 12" - 30" STD & SOLID 6 - ALL BRONZE GRATES, DROP IN GRATES, & 8" & 10" PED/STD GRATES & SOLID COVERS ARE RATED FOR LIGHT DUTY APPLICATIONS ONLY NYLOPLAST DRAIN BASIN: 28 _ _ AG _ _X %ƒ C 2" MIN ‘0$; TOP & FRONT VIEW HOLE SIZE & LOCATION NTS ENLARGED TO SHOW DETAIL A 2 THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. FILL DRAIN BASIN WITH 3 4 " WASHED ROCK COBBLE MULCH (3"-6" CLEAN RIVER ROCK) 18" MIN. WIDTH GEO-TEXTILE FABRIC UNGER COBBLES D DWG SIZE A SCALE 1:16 SHEET 1 OF 1 DWG NO. REV 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 24 IN PERFORATED DRAIN BASIN WITH 24 IN X 12 IN CAP REDUCER & DOME GRATE TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 6-2-06 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWN BY EBC NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 6-2-06 CJA 2.00" MIN ‘0$; BASIN SHOULD BE PERFORATED WITH +2/(63(552: (9(5<ƒ HOLES SHOULD BE STAGGERED EVERY OTHER ROW, AS SHOWN FRONT VIEW HOLE SIZE & LOCATION NTS ENLARGED TO SHOW DETAIL 24" X 12" CAP REDUCER TOP VIEW 12" DOME GRATE (1299CGD) 24" DRAIN BASIN BODY WITHOUT BOTTOM CAP NOTE: ALL DRY WELL GRATES SHALL BE SURROUNDED WITH COBBLE MULCH (SEE DETAIL THIS SHEET). D U C T I L E I R O N - D O N O T P O L L U T D R A I N S T O W A T E R W A Y S E N Y L O P L A S T A %ƒ C PART # GRATE OPTIONS 8" ƒ 4 2808AG PEDESTRIAN/STANDARD SOLID BRONZE DOME DROP IN 10" ƒ 4 2810AG PEDESTRIAN/STANDARD SOLID BRONZE DOME DROP IN 12" ƒ 6 2812AG PEDESTRIAN STANDARD SOLID BRONZE DOME DROP IN 15" ƒ 6 2815AG PEDESTRIAN STANDARD SOLID BRONZE DOME DROP IN 18" ƒ 8 2818AG PEDESTRIAN STANDARD SOLID N/A DOME DROP IN 24" ƒ 8 2824AG PEDESTRIAN STANDARD SOLID N/A DOME DROP IN 30" ƒ 10 2830AG PEDESTRIAN STANDARD SOLID N/A DOME N/A $%$6,16,=(%ƒ$1*/(%(7:((10$1+2/(6&180%(52)+2/(6 D - DEPTH VARIES. 6'-0" MAX. MINIMUM DEPTH SHALL BE 2'-0" BELOW ANY ENCOUNTERED GROUNDWATER. 301 PERMEABLE PAVER EDGE RESTRAINT WATER QUALITY PLATE 303 305 308 302 304 309 306 310 307 ALTERNATE BASE POURED INVERT PRECAST MANHOLE BASE 2 IN. MIN. SLOPE 1 IN. MIN. 8 IN. MIN. 6 IN. 15 IN. OR LESS 48 IN. 18 IN. TO 30 IN. 60 IN. OVER 30 INCHES 72 IN. MIN. MANHOLE MINIMUM INSIDE DIAMETER OF DIAMETER MANHOLE SHALL BE AS FOLLOWS: PIPE SIZE 5 FT. MIN. DEPTH CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE ASTM C-478 ECCENTRIC CONE PRE-FORMED PLASTIC GASKET ASTM C-478 MANHOLE SECTIONS GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET CAST-IN-PLACE CONCRETE BASE 16 IN. MAX. FINISHED GRADE 30 IN. MIN. 48 IN. MAX. VARIABLE 28 IN. MAX. 24 IN. SEE TABLE 6 IN. 12 IN. SLOPE 1 IN./FT. 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. 8 IN. MIN STANDARD MANHOLE WW-3 204 SEWER BEDDING REQUIREMENTS STANDARD MANHOLE 203 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 LOWER LIMIT OF TRENCH WALL SLOPING INITIAL LIFT * 12 IN. MIN. PIPE O.D. 4 IN. MIN. TRENCH WIDTH AS SPECIFIED IN SECTION 02221 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 * BEDDING REQUIRMENTS WW-1 STORMWATER BEDDING ROOF DRAIN CONNECTION E E E E E E E E E E 6" W 6" W E/TV E/TV E/TV S S X X X X X X X X X X X X X X UD UD UD UD UD UD UD UD UD UD UD UD UD UD EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING ASPHALT PARKING LOT FORMER SCOTT AVE. (VACATED 25' ROW) PLUM STREET (ROW VARIES) 5' UTILITY EASEMENT TRASH 5' UTILITY EASEMENT EXISTING RETAINING WALL EXISTING WALL EXISTING FENCE 5' SQ. TREE GRATES, (TYP.) INSTALL TWO 6" BOLLARDS TO PROTECT THE TREE TRUNK PROPOSED STORM DRAIN (BY OTHERS) EXISTING CONCRETE PAN CAMBRIDGE HOUSE LLC 1113 W PLUM ST FORT COLLINS, CO 80521 TOWNSQUARE CONDOS 1209 W PLUM ST FORT COLLINS, CO 80521 COLLINS CAMPUS WEST LLC 1220 W ELIZABETH ST FORT COLLINS, CO 80521 EXISTING RETAINING WALL EXISTING RETAINING WALL SUBDRAIN B SEE SHEET 301 SUBDRAIN A SEE SHEET 301 FULL-DEPTH CONCRETE BAFFLE DETENTION/ STORAGE SECTION LID SECTION DETENTION/ STORAGE SECTION 20' EMERGENCY ACCESS EASEMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU C401 DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R NORTH LEGEND: NOTES: UD PERMEABLE PAVER DOWNSPOUT DISCHARGE TYPICAL PAVER SECTION @ UNDERDRAIN PERMEABLE PAVER OUTFALL PERMEABLE PAVER BAFFLE CO 80521 EXISTING WALL EXISTING RETAINING WALL EXISTING RETAINING WALL EXISTING WALL EXISTING RETAINING WALL TOWNSQUARE CONDOS 1209 W PLUM ST FORT COLLINS, CO 80521 EXISTING 24' PUBLIC ACCESS EASEMENT 5' SQ. TREE GRATES, (TYP.) INSTALL TWO 6" BOLLARDS TO PROTECT THE TREE TRUNK PROPOSED STORM OUTFALL COLLINS CAMPUS WEST LLC 1220 W ELIZABETH ST FORT COLLINS, CO 80521 PROPOSED STORM SEWER DRAIN (BY OTHERS) PLUM STREET (ROW VARIES) 5' UTILITY EASEMENT 5' UTILITY EASEMENT TRASH 5' UTILITY EASEMENT MATCH EXISTING MATCH EXISTING PROPOSED RAMPS NEW 30" VERTICAL CURB & GUTTER PROPOSED DRY WELL EXISTING CONCRETE PAN PROPOSED TRANSFORMER SUBDRAIN B SEE SHEET 301 SUBDRAIN A SEE SHEET 301 EXISTING ASPHALT PARKING LOT 20' EMERGENCY ACCESS EASEMENT WEEPHOLES TO BE PROVIDED IN BUILDING WALL TO ALLOW DRAINAGE PASS-THOUGH LANDSCAPE WALL LANDSCAPE WALL FORMER SCOTT AVE. (VACATED 25' ROW) RAMP RAMP 2 RISERS RETAINING WALL RETAINING WALL These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com C400 LEGEND: NOTES: TF CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R NORTH FRONT ENTRY GRADING DETAIL FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO T T T T T T T T T T T T T T T T T T T X X X X X X X X X T T T T 6" W E E E E E E E E E E E E E E E E E 6" W 6" W G 6" W 6" W E/TV E/TV E/TV 6" W F S S S S X X X X X X X X X X X X X X F S W FDC W F F W UD UD UD UD UD UD UD UD UD UD UD UD UD UD W EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING PROPOSED 6" FIRE LINE PROPOSED 3" WATER SERVICE (RESIDENTIAL) 20"x6" TAPPING SADDLE w/ T.B. & 6" G.V. (S) PROPOSED 3" WATER METER VAULT APPROXIMATE ASPHALT PATCH LIMITS CAMBRIDGE HOUSE LLC 1113 W PLUM ST FORT COLLINS, CO 80521 COLLINS CAMPUS WEST LLC 1220 W ELIZABETH ST FORT COLLINS, CO 80521 EXISTING BUILDING EXISTING 20" WATER MAIN EXISTING FIBER OPTIC LINE EXISTING 8" SANITARY SEWER LINE EXISTING CABLE TV LINE EXISTING WATER SERVICES (TO BE REMOVED) EXISTING ELECTRIC VAULT EXISTING UTILITY POLE EXISTING FIRE HYDRANT EXISTING TELEPHONE LINE PROPOSED TRANSFORMER EXISTING CABLE TV LINE EXISTING GAS LINE TOWNSQUARE CONDOS 1209 W PLUM ST FORT COLLINS, CO 80521 EXISTING 24' PUBLIC ACCESS EASEMENT F F 4' UTILITY EASEMENT CONNECT TO PROPOSED STORM MH (BY OTHERS) 5' SQ. TREE GRATES, (TYP.) INSTALL TWO 6" BOLLARDS TO PROTECT THE TREE TRUNK EXISTING CABLE PEDESTAL EXISTING ASPHALT PARKING LOT PROPOSED FENCE 20"x4" TAPPING SADDLE w/ T.B. & 4" G.V. (S) & 4"x3" REDUCER EXISTING WATER SERVICE TO BE REMOVED EXISTING WATER SERVICE TO BE REMOVED PROPOSED 3 4" WATER SERVICE (COMMERCIAL) FORMER SCOTT AVE. (VACATED 25' ROW) PLUM STREET (ROW VARIES) 5' UTILITY EASEMENT 5' UTILITY EASEMENT TRASH 5' UTILITY EASEMENT EXISTING FIRE HYDRANT PROPOSED 3 4" WATER METER PIT w/ CURB STOP EXISTING UTILITY POLE PROPOSED DRY WELL ACCESS & UTILITY EASEMENT PROPOSED 30" CURB & GUTTER SUBDRAIN B SEE SHEET 301 SUBDRAIN A SEE SHEET 301 36' ACCESS, EMERGENCY ACCESS, DRAINAGE & UTILITY EASEMENT 20' EMERGENCY ACCESS EASEMENT 3 4" TAPPING SADDLE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com C300 NORTH NOTES: LEGEND: W W G G T T E E ST ST S F SS SS FDC CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R TF W UD SIDEWALK 5' SQ. TREE GRATES, (TYP.) INSTALL TWO 6" BOLLARDS TO PROTECT THE TREE TRUNK PROPOSED BIKE RACK (TYP.) 36' EMERGENCY ACCESS, ACCESS, DRAINAGE & UTILITY EASEMENT PROPOSED TRANSFORMER PROPOSED FENCE PAVER EDGE RESTRAINT CONNECT TO EXISTING CONCRETE SIDEWALK, CURB & GUTTER PROPOSED CONCRETE DRIVE APPROACH PROPOSED 5' CONCRETE SIDEWALK PROPOSED CONCRETE DRIVE APPROACH APPROXIMATE ASPHALT PATCH LIMITS FORMER SCOTT AVE. (VACATED 25' ROW) PLUM STREET (ROW VARIES) 5' UTILITY EASEMENT 5' UTILITY EASEMENT TRASH 5' UTILITY EASEMENT R15' R15' R15' R15' 6.5' ADD'L ROW GROUND FLOOR COMMERCIAL PROPOSED DRYWELL FULL-DEPTH CONCRETE BAFFLE 20' EMERGENCY ACCESS EASEMENT EXISTING ASPHALT PARKING LOT RAMP 5' SIDEWALK EXISTING HOLLYWOOD CURB & GUTTER CONNECT TO EXISTING CURB & GUTTER These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R C200 NOTES: NORTH LEGEND: G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W 20" W W W W W W 6" W 6" W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO T T T T T T T T T T T T T T T T T T T X X X X X X 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS W W W W W W W W W W W 4" SS 4" SS 4" SS W W W W W W W W W W W X X X X X T T T T 6" W E E E E E E E E E E E E E E E E E 6" W 6" W G 6" W 6" W E/TV E/TV E/TV 6" W F S S S S CO CO CO CO CO 1201 PLUM ST. EXISTING BUILDING (TO BE REMOVED) 1205 PLUM ST. EXISTING BUILDING (TO BE REMOVED) EXISTING BUILDING (TO BE REMOVED) CAMBRIDGE HOUSE LLC 1113 W PLUM ST FORT COLLINS, CO 80521 COLLINS CAMPUS WEST LLC 1220 W ELIZABETH ST FORT COLLINS, CO 80521 TOWNSQUARE CONDOS 1209 W PLUM ST FORT COLLINS, CO 80521 EXISTING ASPHALT PARKING LOT SCOTT AVE. (25' ROW TO BE VACATED) PLUM STREET (ROW VARIES) APPROXIMATE LOCATION EXISTING FIBER OPTIC LINE EXISTING SS MH RIM=5030.74 INV W (8" CLAY)=5023.11 INV E (8" CLAY)=5023.05 EXISTING SANITARY SERVICE (TO BE REMOVED) EXISTING SS MH RIM=5031.19 INV N (6" CLAY)=5023.47 INV W (8" CLAY)=5023.33 INV E (8" CLAY)=5023.29 EXISTING SS MH RIM=5029.88 INV N (8" CLAY)=5022.64 INV W (8" CLAY)=5022.60 INV E (8" CLAY)=5022.57 APPROXIMATE LOCATION EXISTING 20" WATER MAIN APPROXIMATE LOCATION EXISTING GAS LINE EXISTING FIRE HYDRANT EXISTING TREE (TYP.) APPROXIMATE LOCATION EXISTING CABLE TV LINE APPROXIMATE LOCATION EXISTING SIGN EXISTING SIGN (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING WATER SERVICES (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING GAS SERVICES (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING TELEPHONE SERVICES (TO BE REMAIN OR REALIGN) EXISTING CABLE TV SERVICE (TO BE REMOVED) EXISTING FENCE LINE (TO BE REMOVED) EXISTING SANITARY SEWER SERVICES (TO BE REMOVED) EXISTING FENCE (TO BE REMOVED) EXISTING WATER METER (TO BE REMOVED) EXISTING ELECTRICAL SERVICE (TO BE REMOVED) EXISTING GAS SERVICE (TO BE REMOVED) EXISTING FENCE LINE (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING CABLE TV LINE (TO BE REMAIN OR REALIGN) APPROXIMATE LOCATION OF EXISTING CABLE TV SERVICE (TO BE REMOVED) EXISTING BUILDING (TO BE REMOVED) EXISTING ELECTRICAL VAULT EXISTING FENCE EXISTING FENCE EXISTING SANITARY SEWER LINE (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING GAS SERVICE (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING GAS SERVICE (TO BE REMOVED) EXISTING MAILBOX (TO BE REMOVED) EXISTING SIGN (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING GAS SERVICE (TO BE REMOVED) EXISTING SANITARY CLEAN OUT (TO BE REMOVED) EXISTING GRAVEL (TO BE REMOVED) EXISTING CONCRETE (TO BE REMOVED) EXISTING CURB, GUTTER, & SIDEWALK (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING CABLE TV LINE (TO BE REMAIN) APPROXIMATE LOCATION EXISTING GAS LINE EXISTING SIGN EXISTING CURB, GUTTER, & SIDEWALK EXISTING CURB & GUTTER EXISTING SANITARY CLEAN OUT (TO BE REMOVED) EXISTING FENCE (TO BE REMOVED) EXISTING RETAINING WALL APPROXIMATE LOCATION OF EXISTING CABLE TV SERVICE (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING GAS SERVICES (TO BE REMOVED) EXISTING TELEPHONE & CABLE PEDESTAL EXISTING ELEC METER (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING WATER SERVICE (TO BE REMOVED) EXISTING FENCE (TO REMAIN) EXISTING CONCRETE PAN EXISTING TELEPHONE PEDESTAL STORM MH RIM=5029.1 INV IN (W)=5025.77 INV IN (N)=5025.77 INV OUT (E)=5025.77 (3) EXISTING CURB STOPS (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING WATER SERVICE (TO BE REMOVED) EXISTING CURB STOP & METER PIT (TO BE REMOVED) 809 SCOTT AVE. EXISTING BUILDING (TO BE REMOVED) 813 SCOTT AVE. EXISTING BUILDING (TO BE REMOVED) APPROXIMATE LOCATION OF EXISTING ELECTRIC TRANSFORMER EXISTING CABLE/TV LINE TO REMAIN / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / STORM MH RIM=5029.5 INV IN (N)=5025.93 INV OUT E)=5025.93 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com C100 DEMOLITION PLAN EXISTING CONDITIONS AND CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R NORTH E LEGEND: G T ST FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: NOTES: SS W X VAULT ELEC CONTROL IRR E/TV TREE PROTECTION NOTES: 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Final Drainage and Erosion Control Report for Scott Plaza dated January 29, 2014 by Northern Engineering shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by thE construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the City of Fort Collins. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: City of Fort Collins Benchmark 19-97 At the southeast corner of West Elizabeth and Shields Street, on a concrete traffic signal base. Elevation=5022.56 City of Fort Collins Benchmark 20-97 At the southwest corner of West Elizabeth and Constitution Avenue, on a concrete traffic signal base. Elevation=5046.97 Basis of Bearings The Basis of Bearing is the South line of the Southeast Quarter of the Northeast Quarter, Section 15, Township 7 North, Range 69 West of the 6th 30DVEHDULQJ1RUWKƒ :HVW 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: a. Modification to standard parkway width from LCUASS requirement of 8' to proposed parkway width of 6.5'. b. Modification to standard easement dedication along Plum Street. c. Modification to minimum driveway spacing between Bluebell and eastern driveway access. CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. For additional information see separate Stormwater Management Plan / Erosion Control Report for Scott Plaza. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Final Drainage and Erosion Control Report for Scott Plaza dated January 29, 2014 by Northern Engineering shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal box and tracer wire test lid per City Water Detail 25. (970) 221-4158 Delich Associates Joe Delich 2272 Glen Haven Drive Loveland, Colorado 80538 (970) 669-2061 SiteWise, LLC 7000 N. Broadway Building 3, Suite 306 Denver, Colorado 80221 (303) 650-8680 ** The underground utility locates provided by SiteWise, LLC are based upon the best available information at the time of locating. Contractor acknowledges that it is common for underground facility owner maps to have errors and omissions of data shown. Consequently, it is the Contractor's sole responsibility to field verify the location of all utilities prior to construction, and notify the Engineer of any discrepancies found. Ŷ land planning Ŷ landscape architecture Ŷ Ŷ urban design Ŷ entitlement Ŷ VICINITY MAP NORTH I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: BENCHMARK #1: City of Fort Collins Benchmark 19-97 At the southeast corner of West Elizabeth and Shields Street, on a concrete traffic signal base. Elevation=5022.56 BENCHMARK #2: City of Fort Collins Benchmark 20-97 At the southwest corner of West Elizabeth and Constitution Avenue, on a concrete traffic signal base. Elevation=5046.97 Basis of Bearings The Basis of Bearing is the South line of the Southeast Quarter of the Northeast Quarter, 6HFWLRQ7RZQVKLS1RUWK5DQJH:HVWRIWKHWK30DVEHDULQJ1RUWKƒ :HVW ORIGINAL FIELD SURVEY: NORTHERN ENGINEERING SERVICES DATE: November 21, 2008 ADDITIONAL FIELD SURVEYS: NORTHERN ENGINEERING SERVICES DATE: December 2008; August 2011 ORIGINAL FIELD SURVEY BY: TERRACON CONSULTANTS, INC. GEOTECHNICAL ENGINEERING REPORT - PROPOSED STUDENT HOUSING SCOTT AVENUE AND WEST PLUM STREET TERRACON PROJECT NO. 20135030 DATE: SEPTEMBER 18, 2013 SUBSURFACE EXPLORATION BY: PROJECT BENCHMARKS: C000 C001 N O R T H E RN N O R T H E RN COVER SHEET GENERAL AND CONSTRUCTION NOTES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com C000 C100 EXISTING CONDITIONS AND DEMOLITION PLAN C200 PAVING PLAN C300 UTILITY PLAN C400 GRADING PLAN C600 DRAINAGE EXHIBIT Justin Larson, AIA, LEED AP Vaught Frye Larson Architects 401 Mountain Avenue, Suite 100 Fort Collins, Colorado 80521 (970) 224-1191 VAUGHT FRYE LARSON architects C301 SUBDRAINS A & B PLAN & PROFILE C401 SUBGRADE PLAN C500-503 CONSTRUCTION DETAILS C601 STATIC EROSION CONTROL EXHIBIT C602 EROSION CONTROL DETAILS