HomeMy WebLinkAboutRIDGEWOOD HILLS RESIDENCES, 4TH FILING - FDP - FDP130052 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLAN (7)16
14
14
7
13
13
11
7
10
8-UNIT
8-UNIT
6-UNIT
6-UNIT
17'
(TYP)
24'
(TYP)
17'
(TYP)
28'
24'
15' BUILDING
SETBACK
15'
15' BUILDING SETBACK
50' FL-FL (EXISTING) 8' 5' 15' 24.7'
EXISTING LIGHT
EXISTING LIGHT
EXISTING LIGHT
9' EXISTING
U&DE
TOT
LOT
SPORTS
COURT
(110' X 50')
CLUB
HOUSE
POOL
AVONDALE ROAD
20'
EXISTING LIGHT
58.8'
120.1'
24'
17' 24'
15'
6' EXISTING U&DE
15' BUILDING SETBACK
ENHANCED
CROSS WALK TO
MATCH EXISTING
12'
7' 17'
(TYP)
24'
(TYP)
17'
(TYP)
7'
TRASH ENCLOSURE,
(TYP)
11' 5' 9'
(TYP)
11' 5' 11'
11' 5' 11'
(10) UNIT
GARAGE
(6) UNIT
GARAGE
29'
24'
5' (TYP)
5'
15'
6'
EXISTING 57' ROW
36' FL - FL 8.5' 5'
9' EXISTING
U&DE
5'
6' 6'
15.6'
6'
18.5'
6'
6'
20'
68.5'
113.5'
20'
5' 11'
30'
U,D&EAE
30'
U,D&EAE
30'
U,D&EAE
30'
U,D&EAE
30'
U,D&EAE
TRACT
B
SITE DISTANCE
EASEMENT
20'
51.4'
85.4'
95.7'
59.3'
44'
43.9'
TRIANGLE DRIVE
EMERGENCY ACCESS ONLY WITH
GATE COMPLYING WITH 503.6 OF
THE IFC. SEE NOTE #2, THIS SHEET.
GATE TO BE SECURED WITH A
KNOX PADLOCK.
3' ACCESS EASEMENT
CONCRETE
PET STATION,
SEE DETAIL SHEET 4
IMPERVIOUS CAPTURE
AND BIOSWALE, SEE
LID SHEETS
CROSS WALK
20'
DE
8-UNIT
NORTH
0 15' 30' 60' 90'
SCALE: 1"= 30'-0"
15
MATCHLINE
(SEE SHEET 3 OF 8)
LEGEND:
PARKING SPACES
BIKE PARKING SPACE
BIKE PARKING SPACE (COVERED/GARAGE)
1. TRASH REMOVAL SHALL BE RESTRICTED TO BUSINESS HOURS
ONLY (8AM TO 5PM, MON.-FRI.)
2. THE SECOND POINT OF ACCESS FOR EMERGENCY VEHICLES
ONLY THAT INTERSECTS WITH TRIANGLE DRIVE SHALL INCLUDE
A SECURITY DEVICE THAT BLOCKS TRAFFIC AND POSTED WITH A
SIGN IN ACCORDANCE WITH THE REQUIREMENTS OF THE
POUDRE FIRE AUTHORITY. IN ADDITION, THIS EMERGENCY
ACCESS DRIVE MUST NOT BE USED BY ANY PARTY FOR PARKING,
STORAGE OR MAINTENANCE OF VEHICLES, TRAILERS OR
EQUIPMENT OF ANY KIND. FURTHER, THIS DRIVE MUST BE KEPT
FREE OF RUBBISH, DIRT, DEBRIS, COMPOST, CONSTRUCTION
WASTE, AND SNOW OBSTRUCTIONS.
3. TRACT 'A' IS ZONED M-M-N AND TRACT 'B' IS ZONED L-M-N.
4. ALL POLE-MOUNTED AND BUILDING-MOUNTED LIGHTING SHALL
FEATURE FULLY SHIELDED, DOWN DIRECTIONAL AND DARK SKY
COMPLIANT FIXTURES AND COMPLY WITH SECTION 3.2.4 OF THE
LAND USE CODE.
5. ALL BUILDING AND GROUND-MOUNTED MECHANICAL
EQUIPMENT WILL BE SCREENED AND PAINTED A
REQUIRED BY THE LAND USE CODE.
NOTES:
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE
LANDSCAPE ARCHITECT.
1269 N Cleveland Ave, Loveland CO 80537
(970) 669.3737
design@tfgdesign.com www.tfgdesign.com
ATTN:
SHEET OF
SHEET NUMBER:
SHEET TITLE:
REVISIONS:
PROJECT INFORMATION:
OWNER:
DRAWN BY:
FILE LOCATION: C:\TFG_David\Working Temp\Ridgewood\Ridgwood Hills - FP.dwg
PLOT DATE: 12/13/2013 9:16 AM
PROJECT NUMBER:
DATE:
PHASE:
M. Timm Development
Bill Timm
233 Carillo Street
Santa Barbara, CA 93101
(805) 963-0358
RIDGEWOOD HILLS - FOURTH FILING
AVONDALE RD & TRIANGLE DR
FORT COLLINS, COLORADO
111-122FC
DEC 13, 2013
FP
8