Loading...
HomeMy WebLinkAboutSPRING CREEK FARMS NORTH, FOURTH FILING - PDP - PDP130014 - REPORTS - RECOMMENDATION/REPORTITEM NO ________________ MEETING DATE December 12, 2013 STAFF Holland ____ PLANNING & ZONING BOARD Planning Services 281 N College Ave – PO Box 580 – Fort Collins, CO 80522-0580 fcgov.com/developmentreview/ 970.221.6750 STAFF REPORT PROJECT: Spring Creek Farms North, Fourth Filing Project Development Plan, PDP #130014 and Modifications of Standard to Sections: 3.2.3(C) Solar-Oriented Residential Lots, 4.27(D)(2) Secondary Uses in E Zone, 4.27(D)(5) Density/Intensity in E Zone and, 4.27(B)(3)(a)(1) Single-Family lot size. APPLICANT: Terence Hoaglund Vignette Studios P.O. Box 1889 Fort Collins, CO 80522-1889 OWNER: SC Residential, LLC 6300 S. Syracuse Way #293 Centennial, CO 80111 PROJECT DESCRIPTION: This is a request to subdivide 15.23 acres into 76 lots for single-family detached homes. The site is located along the west side of Joseph Allen Drive and is approximately 250 feet north of the intersection of Joseph Allen Drive and East Drake Road. A Union Pacific/Southern Pacific rail line is located approximately 75 feet west of the parcel. The project contains approximately 13 acres in the L-M-N, Low Density Mixed-Use Neighborhood zone district and 2 acres in the E, Employment zone district. The PDP includes a request for four modifications of standard associated with minimum density, secondary use requirements and maximum lot size in the Employment zone district as well as a modification to the minimum standard for solar oriented lots. RECOMMENDATION: Approval of Spring Creek Farms North, Fourth Filing Project Development Plan, PDP #130014, and Modifications of Standard to Sections 3.2.3(C) Solar-Oriented Residential Lots, 4.27(D)(2) Secondary Uses, 4.27(D)(5) Density/Intensity and 4.27(B)(3)(a)(1) Single-Family maximum lot size in the Employment zone. Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 2 EXECUTIVE SUMMARY: The approval of Spring Creek Farms North, Fourth Filing Project Development Plan complies with the applicable requirements of the City of Fort Collins Land Use Code (LUC), more specifically: • The P.D.P. complies with process located in Division 2.2 – Common Development Review Procedures for Development Applications of Article 2 – Administration. • The four Modifications of Standard to Sections 3.2.3(C) Solar-Oriented Residential Lots, 4.27(D)(2) Secondary Uses, 4.27(D)(5) Density/Intensity and 4.27(B)(3)(a)(1) Single-Family maximum lot size in the Employment zone meet the applicable requirements of Section 2.8.2(H), and the granting of these Modifications would not be detrimental to the public good. • The P.D.P. complies with relevant standards located in Division 4.5, Low Density Mixed-Use Neighborhood (L-M-N) of Article 4 – Districts. • The P.D.P. complies with relevant standards located in Division 4.27, Employment (E) of Article 4 – Districts, subject to approval of the three Modifications of Standard to Sections 4.27(D)(2) Secondary Uses, 4.27(D)(5) Density/Intensity and 4.27(B)(3)(a)(1) Single-Family maximum lot size in the Employment zone. • The P.D.P. complies with relevant standards located in Article 3 – General Development Standards, subject to approval of the Modification of Standard to Section 3.2.3(C) Solar-Oriented Residential Lots. • The P.D.P. continues to comply with the Spring Creek Farms North Overall Development Plan (O.D.P.). COMMENTS: 1. Background: The surrounding zoning and land uses are as follows: Direction Zone District Existing Land Uses North Industrial (I) Timberline Center Storage Units, Light Industrial Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 3 South Low Density Mixed-Use Neighborhood (L-M-N) Outlot A vacant parcel, Spring Creek Farms North East Medium Density Mixed-Use Neighborhood (M-M-N) Spring Creek Farms North Second Filing, multi-family West Low Density Residential R-L) Union Pacific/Southern Pacific Railroad; Power Line Open Space Trail; Parkwood East neighborhood • The property was annexed in November 1997 as part of the Timberline Annexation and was originally zoned T – Transition. • A request to amend the Structure Plan and rezone the property to L-M-N, M-M-N, and E was approved on 2 nd reading by City Council on January 16, 2001. • The parcel is part of the 55 acre Spring Creek Farms North Overall Development Plan (O.D.P.), first approved in February of 2001. In 2004, there was a minor amendment that added a plan note to the M-M-N portion of the O.D.P. allowing additional permitted M-M-N uses. The 2004 O.D.P. minor amendment also removed the plan note that described a potential bicycle and pedestrian connection across the railroad corridor. • In April 2011, the L-M-N portion of the O.D.P. (where the subject parcel is located) was amended to allow all Low Density Mixed-Use Neighborhood Zone District (L-M-N) uses. The previous O.D.P. (2001) specifically called out single family residential: attached and detached, as well as two family dwellings, as the L-M-N uses for the subject property. The Spring Creek Farms North Overall Development Plan is attached with this staff report. 2. Compliance with Applicable L-M-N Standards: The project complies with all applicable L-M-N standards with the following relevant comments provided: A. Section 4.5(A) – Purpose The proposed single-family land use is consistent with the purpose of the L-M-N district by proposing a predominance of low density housing with a fully integrated small park providing a focal point within the pattern of streets and blocks. Typically, Low Density Neighborhoods are clustered around and integral with a Medium Density Mixed-Use Neighborhood, and in this case the project is adjacent to the “Trails at Timberline” multi-family development (Spring Creek Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 4 Farms North Filing Two), located adjacent to the project, east of Joseph Allen Drive. B. Section 4.5(B)(2)(a)(1) – Permitted Uses Single family detached dwellings are a permitted use in the L-M-N District subject to administrative review. C. Section 4.5(D)(1) – Density This standard requires that residential density on parcels less than 20 acres have a density not less than 3.00 dwelling units per gross acre and not greater than 9.00 per net acre. The P.D.P. provides 69 units in the L-M-N zone district for a density of 5.29 dwelling units per gross acre. D. Section 4.5(D)(6) – Small Neighborhood Park A small neighborhood was approved to satisfy this standard under a separate Type 1 P.D.P. (Spring Creek Farms North Third Filing), which provided one acre of additional functional open space for the project and the surrounding neighborhoods. This park was planned to satisfy the park requirement for the M- M-N zoned multi-family project to the east (Spring Creek farms North Second Filing) as well as the park requirement for this project. 3. Compliance with Applicable Employment District Standards: A. Section 4.27(B)(3)(a)(1) – Permitted Uses Single family detached dwellings located on lots containing no more than 6,000 square feet are a permitted use in the Employment zone district subject to review by the Planning and Zoning Board. One of the six lots (Block 2, Lot 2) located in the E zone exceeds the 6,000 square foot maximum and a modification of this standard is proposed for this lot. Of the total 76 lots proposed, 70 lots are approximately 6,000 square feet or less. The remaining five lots in the L-M-N zone are approximately 7,000 square feet each. A summary of the typical lot dimensions and area is included in the following table. Areas for some of the lots vary due to the street layout. Typical Lot Dimensions Typical Lot area (square feet) Quantity Percentage of Total Lots 47 x 100 4,700 8 10% 50 x 100 5,000 28 37% 52 x 100 5,200 10 13% 60 x 100 6,000 24 32% 70 x 100 7,000 6 8% Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 5 B. Section 4.27(D)(2) – Secondary Uses The proposed residential use is considered a secondary use in the Employment zone district, and this standard requires that secondary uses be limited to 25% of the total gross area within the portion of the development plan in the Employment zone. The applicant is requesting a modification for 35% secondary residential use area in the Employment zone district portion of the plan. C. Section 4.27(D)(5) – Density / Intensity This standard requires that all residential development within the Employment District have an overall minimum average density of seven dwelling units per net acre of residential land. The applicant is requesting a modification from 7 units per net acre to 3.21 units per net acre in the Employment zone district portion of the plan. 4. Compliance with Article 3 of the Land Use Code – General Development Standards The project complies with all applicable General Development Standards with the following relevant comments provided: A. Section – 3.2.1 Landscaping Street trees are provided at approximately 40-foot intervals along portions of the streets that are not fronted by lots. Additionally, along the front setbacks of lots, one street tree per lot is provided in substitution for 40-foot tree spacing. The project also meets the minimum tree species diversity requirement of this section. B. Section 3.2.2 – Access, Circulation and Parking In conformance with the Purpose, General Standard, and Development Standards described in this section, the parking and circulation system provided with the project is well designed with regard to safety, efficiency and convenience for vehicles, bicycles, pedestrians and transit, both within the development and to and from surrounding areas. C. Section 3.2.2(C)(6) – Direct On-Site Access to Pedestrian and Bicycle Connections The proposed street sidewalk system is designed with block lengths that are spaced at intervals less than the 660 feet maximum permitted. The development was planned to incorporate the small neighborhood park as an integrated feature Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 6 which provides additional convenient pedestrian and bicycle connections through the center of the project on routes not associated with a street. D. Section 3.2.3(C) – Solar-Oriented Residential Lots This standard requires that 65% of the lots be solar-oriented. The project can provide only 25 solar-oriented lots, or 33%, due to the predominate north / south orientation of the overall boundaries of the site. A modification request is provided with this P.D.P. E. Section 3.3.1 – Plat Standards All lots have direct access to a public street. The layout of roads, driveways, utilities, drainage facilities, and other services are designed in a way that enhances an interconnected system within and between developments to the east and south. The plat demonstrates proper dedication of public rights-of-way, drainage easements and utility easements that are needed to serve the area being developed. F. Section 3.5.2(E) Residential Building Setbacks, Lot Width and Size The project is in compliance with this section, which requires a minimum lot width of 50 feet for single-family detached dwellings if the garage is served by access from the abutting street. Eight of the lots are 42 feet in width and permitted to be less than 50 feet in width because the garages will be accessed by an alley. Additionally, the proposed project provides the following setbacks in conformance with the standards: • 15-feet Front Yard • 20-feet Garage • 5-Interior Side Yard • 15-feet Corner Side • 8-feet Rear Yard G. Section 3.6.4 Transportation Level of Service Requirements The Traffic Operations and Engineering Departments have reviewed the Transportation Impact Study that was submitted to the City for review and have determined that the vehicular, pedestrian and bicycle facilities proposed with this P.D.P are consistent with the standards contained in Part II of the City of Fort Collins Multi-modal Transportation Level of Service Manual. Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 7 H. Section 3.8.26 Residential Buffering This buffer requirement applies to all proposed residential developments that are located adjacent Industrial uses. The existing self-storage facility located to the north of the project is considered a light industrial use. In accordance with this standard, the applicant is providing a buffer yard with evergreen, ornamental and shade trees planted along the length of the residential lots. The self-storage facility also provided landscaped open space with their development plan, which adds to the buffer and augments the separation of uses. MODIFICATIONS OF STANDARD: Land Use Code Modification Criteria: “The decision maker may grant a modification of standards only if it finds that the granting of the modification would not be detrimental to the public good, and that: (1) the plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested; or (2) the granting of a modification from the strict application of any standard would, without impairing the intent and purpose of this Land Use Code, substantially alleviate an existing, defined and described problem of city-wide concern or would result in a substantial benefit to the city by reason of the fact that the proposed project would substantially address an important community need specifically and expressly defined and described in the city's Comprehensive Plan or in an adopted policy, ordinance or resolution of the City Council, and the strict application of such a standard would render the project practically infeasible; or (3) by reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property, including, but not limited to, physical conditions such as exceptional narrowness, shallowness or topography, or physical conditions which hinder the owner's ability to install a solar energy system, the strict application of the standard sought to be modified would result in unusual and exceptional practical difficulties, or exceptional or undue hardship upon the owner of such property, provided that such difficulties or hardship are not caused by the act or omission of the applicant; or (4) the plan as submitted will not diverge from the standards of the Land Use Code that are authorized by this Division to be modified except in a nominal, inconsequential way when considered from the perspective of the entire Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 8 development plan, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. Any finding made under subparagraph (1), (2), (3) or (4) above shall be supported by specific findings showing how the plan, as submitted, meets the requirements and criteria of said subparagraph (1), (2), (3) or (4). 5. Modification of Standard Request to Section 3.2.3(C) Solar-Oriented Residential Lots A. The standard: Section 3.2.3(C) Solar-Oriented Residential Lots At least sixty-five (65) percent of the lots less than fifteen thousand (15,000) square feet in area in single- and two-family residential developments must conform to the definition of a "solar-oriented lot" in order to preserve the potential for solar energy usage. Solar-oriented lot shall mean: (1) a lot with a front lot line oriented to within thirty (30) degrees of a true east- west line. When the lot line abutting a street is curved, the "front lot line" shall mean the chord or straight line connecting the ends of the curve. For a flag lot, the "front lot line" shall mean the lot line that is most parallel to the closest street, excluding the "pole portion of the flag lot"; or (2) a lot which, when a straight line is drawn from a point midway between the side lot lines at the required front yard setback to a point midway between the side lot lines at the required rear yard setback, is oriented to within thirty (30) degrees of true north along said line; or (3) a corner lot with a south lot line oriented to within thirty (30) degrees of a true east-west line, which south lot line adjoins a public street or permanently reserved open space; provided, however, that the abutting street right-of-way or open space has a minimum north-south dimension of at least fifty (50) feet. For the purposes of this definition, "permanently reserved open space" shall include, without limitation, parks, cemeteries, golf courses and other similar outdoor recreation areas, drainage ditches and ponds, irrigation ditches and reservoirs, lakes, ponds, wetlands, open spaces reserved on plats for neighborhood use and other like and similar permanent open space. Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 9 B. Description of the Modification: The applicant has submitted a request for approval of a Modification of Standard to Section 3.2.3(C) Solar-Oriented Residential Lots requesting that the project provide 33 percent solar-oriented defined lots. C. Applicant’s Justification: The applicant contends that the parcel of land is unique in that it is relatively narrow (360+’ feet east to west) and long (1940+- feet north to south). With this shape, there is limited ability for lot and street placement within the parcel to create a functional and economical development, taking into consideration all the dynamics of development, including, but not limited to solar orientation, utilities, drainage patterns, and the existing park (Spring Creek Farms Third Filing). While various layout options were considered, the current site plan was determined to be the best solution to meet all the various criteria. This site plan has one north south street (Adobe Drive) towards the west side, with three east - west streets for connectivity to Joseph Allen Drive. With this, lots were oriented to these east-west streets to provide as many solar oriented lots as possible. In addition, the lots on the Southern cul-de-sac of Adobe Drive were also oriented as much as possible to meet the solar orientation standards. Due to the unique property shape, being relatively thin and long, it is not practical to meet the strict interpretation of the solar orientation standards. We have included as many solar oriented lots as reasonably practical with the property shape, with 33% of the lots meeting the solar orientation requirement. D. Staff Finding for the Modification: Staff finds that the request for the Modification of Standard to Section 3.2.3(C) Solar-Oriented Residential Lots is justified by the applicable standards in 2.8.2(H). The granting of the Modifications would not be detrimental to the public good and: The request satisfies Criteria (2.8.2(H)(3): By reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property, including, but not limited to, physical conditions such as exceptional narrowness, shallowness or topography, or physical conditions which hinder the owner's ability to install a solar energy system, the strict application of the standard sought to be modified would result in unusual and exceptional practical difficulties, or exceptional or undue hardship upon the owner of such property, provided that such difficulties or hardship are not caused by the act or omission of the applicant. Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 10 This is because the project boundary has an exceptionally long north-to-south orientation and narrow width, which is an exceptional physical condition not caused by the applicant, that creates a logical arrangement of streets and lots with an orientation that limits the provision of solar oriented lots. 6. Modification of Standard to Section 4.27(D)(2) Secondary Uses in E Zone A. The standard: Secondary Uses. All secondary uses shall be integrated both in function and appearance into a larger employment district development plan that emphasizes primary uses. A secondary use shall be subject to administrative review or Planning and Zoning Board review as required for such use in Section 4.27(B). The following permitted uses shall be considered secondary uses in this zone district and together shall occupy no more than twenty-five (25) percent of the total gross area of the development plan. (d) Residential uses (except mixed-use dwellings when the residential units are stacked above a primary use which occupies the ground floor). B. Description of the Modification: The applicant is requesting a modification to increase the secondary residential use area to 35% in the Employment zone district portion of the plan. C. Applicant’s Justification: The applicant contends that within the entire ODP, the overall E zone is 6.2 acres. This 6.2 acres of E zoned land was bisected by the construction of Joseph Allen Drive, creating a smaller portion of E zone land which is part of this P.D.P. with a gross acreage of 2.18 acres. Due to an irrigation easement along the southern portion of the 2.18 acres, the area has a usable acreage of about 1.85 acres. The applicant contends that remaining 1.85 acre E zone area within the project boundary is not feasible as a primary use, such as a office building or industrial use, due to the small usable size of the area and its less visible, less desirable location set back from Timberline Road. Additionally, the applicant contends that in compliance with the standard, 1.5 acres of the 2.18 E zone area could be developed as a residential use in conformance with the 25% limit, and if this was proposed, only 0.68 acres would remain of the total E zone project area. The designation of Joseph Allen Drive as the logical boundary between primary and secondary uses, by adding the remaining 0.68 acres as additional secondary use, is equal to or better than a Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 11 plan which divides the primary and secondary use areas based on the required percentage. D. Staff Finding for the Modification: Staff finds that the request for the Modification of Standard to 4.27(D)(2) to increase the allowable residential secondary use in Employment District to 35% is justified by the applicable standards in 2.8.2(H). The granting of the Modifications would not be detrimental to the public good and: The request satisfies Criteria (2.8.2(H)(1): The plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested. This is because Joseph Allen Drive provides a more logical boundary separating the primary and secondary uses in the 6.2 acre Employment District area that is applicable to this P.D.P., and the land use pattern resulting from the increased percentage is equal to or better than a plan which divides the primary and secondary use areas based on the required percentage. 7. Modification of Standard to Section 4.27(D)(5) Density/Intensity in E Zone A. The standard: Density/Intensity. All residential development in the E Employment District shall have an overall minimum average density of seven (7) dwelling units per net acre of residential land. B. Description of the Modification: The applicant is requesting a modification to decrease the density in the Employment zoned portion of the plan to 3.21 dwelling units per acre. C. Applicant’s Justification: The applicant contends that with the relatively small size of the E zone parcel, it is desirable to simply continue the single family use and lot pattern of the L-M-N portion of the site. While the applicant would like to have more density in the E zone area, the location of the existing underground irrigation ditch also impacts the layout for the single family units. Seven lots are proposed on the E zone portion of the project resulting in 3.21 units per acre. If the irrigation ditch did not exist, three additional lots could easily be added. At 7 units per acre, the required density on this site would be 16 units. Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 12 If both the LMN and E parcels are taken into consideration, the decrease in density becomes nominal and inconsequential. As shown in the table below, if both parcels were to be developed at the minimum densities, then a total of 55 units would be required. However, since we are proposing to develope the L-M-N portion at a higher density than required, overall we are providing a total of 76 units -- this is 21 more units than the minimum density would require. Parcel Min Density (unit/acre) Min Units Density Shown (unit/acre) Total Units LMN (13.05 acres) 3 39 5.29 69 E (2.18 acres) 7 16 3.2 7 Total (15.23 acres) 55 4.99 76 (21 units more than the minimum required overall) As can be seen, the reduction in density in the E zone becomes nominal and inconsequential if the project is looked at as a whole. Therefore, the proposed use would be equal to or better than what would be required under the Land Use Code. D. Staff Finding for the Modification: Staff finds that the modification is justified based on several factors: • The E zone area of the project represents only a small portion of the project overall. • The standard density range permitted in L-M-N is 3 units/acre minimum, and 9 units/acre maximum. The density in the E zone has a nominal effect on the reduction of density over the entire development plan with the overall L-M-N density dropping from 5.29 units/acres to 4.99 units/acre. • The overall 4.99 units/acre is in the mid-range of density permitted in the L-M-N zone where the majority of the project is located, with the development plan providing an additional 21 dwelling units more than the Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 13 minimum required overall, resulting in a density that is over the minimum required. • The overall density achieved continues to advance the purposes of the Land Use Code as contained in Section 1.2.2, specifically: 1.2.2(K) – fostering a more rational pattern of relationship among residential, business and industrial uses for the mutual benefit of all. Staff finds that the request for the Modification of Standard to section 4.27(D)(5) Density/Intensity in E Zone is justified by the applicable standards in 2.8.2(H). The granting of the Modifications would not be detrimental to the public good and: The request satisfies Criteria (2.8.2(H)(4): The plan as submitted will not diverge from the standards of the Land Use Code that are authorized by this Division to be modified except in a nominal, inconsequential way when considered from the perspective of the entire development plan, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. This is because the E zone parcel is a small portion of the entire development area, and the reduced density in the E zone has a nominal effect on the reduction of density over the entire development plan, with the development plan providing an additional 21 dwelling units more than the minimum required overall, resulting in a density that is over the minimum required. The overall density achieved continues to advance the purposes of the Land Use Code as contained in Section 1.2.2, specifically: 1.2.2(K) – fostering a more rational pattern of relationship among residential, business and industrial uses for the mutual benefit of all. 8. Modification of Standard to Section 4.27(B)(3)(a)(1) Single-Family lot size A. The standard: (3) The following uses are permitted in the E District, subject to review by the Planning and Zoning Board: (a) Residential Uses: 1. Single-family detached dwellings located on lots containing no more than six thousand (6,000) square feet. Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 14 B. Description of the Modification: The modification request is to allow one single-family lot (Lot 2 Block 2) to be larger than the 6,000 square feet maximum permitted in the E zone, for a total area of approximately 6,255 square feet for the lot. C. Applicant’s Justification: The last modification request is to allow one lot (Lot 2 Block 2) to be slightly larger than 6,000 square feet. This is due to the configuration of the site rather than any specific desire to have the lot be larger than allowed. It is also desirable to continue the lot mix in the L-M-N parcel with a variety of lot widths to accommodate different products. Lot 2, Block 2: The typical lot size for this type C lot is 60 feet wide by 100 feet deep, for a 6,000 square foot lot. However, as is true in many locations, the public street is not 100% parallel with the rear lot line, therefore this particular lot is about 103 feet deep, for a lot area of 6,255 square feet. The average lot size for the seven lots is 5,874 square feet. The applicant contends that the increase in lot area for the one lot is fairly minor, and would not be noticeable by the general public, therefore the proposed modification would be equal to or better than what would be required by code. D. Staff Finding for the Modification: Staff finds that the request for the Modification of Standard to Section 4.27(B)(3)(a)(1) Single-Family lot size is justified by the applicable standards in 2.8.2(H). The granting of the Modifications would not be detrimental to the public good and: 1) The request satisfies Criteria (2.8.2(H)(1): The plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested. This is because the increase in lot area for the one lot is minimal, and the proposed lot size promotes the general purpose of the standard in a manner that is equal to the purpose of the standard; and 2) The request satisfies Criteria (2.8.2(H)(4): The plan as submitted will not diverge from the standards of the Land Use Code that are authorized by this Division to be modified except in a nominal, inconsequential way when considered from the perspective of the entire Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 15 development plan, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. This is because the increase in lot area for the one lot is nominal, with the overall development area in the E zone maintaining an average lot size of 5,874 square feet, in conformance with the standard. The overall average lot size achieved continues to advance the purposes of the Land Use Code as contained in Section 1.2.2, specifically: 1.2.2(K) – fostering a more rational pattern of relationship among residential, business and industrial uses for the mutual benefit of all. 9. Neighborhood Meeting A City neighborhood meeting was held for the proposed project. A neighborhood meeting summary and letters from the neighbors are attached with this staff report. 10. Findings of Fact/Conclusion In evaluating Spring Creek Farms North, Fourth Filing Project Development Plan, Staff makes the following findings of fact: A. The Modification of Standard to Section 3.2.3(C) Solar-Oriented Residential Lots is justified by the applicable standards in 2.8.2(H). The granting of the Modifications would not be detrimental to the public good, and: The request satisfies Criteria (2.8.2(H)(3): By reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property, including, but not limited to, physical conditions such as exceptional narrowness, shallowness or topography, or physical conditions which hinder the owner's ability to install a solar energy system, the strict application of the standard sought to be modified would result in unusual and exceptional practical difficulties, or exceptional or undue hardship upon the owner of such property, provided that such difficulties or hardship are not caused by the act or omission of the applicant. This is because the project boundary has an exceptionally long north-to- south orientation and narrow width, which is an exceptional physical condition not caused by the applicant, that creates a logical arrangement Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 16 of streets and lots with an orientation that limits the provision of solar oriented lots. B. The Modification of Standard to 4.27(D)(2) to increase the allowable residential secondary use in the Employment District from 25% to 35% is justified by the applicable standards in 2.8.2(H). The granting of the Modifications would not be detrimental to the public good, and: The request satisfies Criteria (2.8.2(H)(1): The plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested. This is because Joseph Allen Drive provides a more logical boundary separating the primary and secondary uses in the 6.2 acre Employment District area that is applicable to this PDP, and the land use pattern resulting from the increased percentage is equal to or better than a plan which divides the primary and secondary use areas based on the required percentage. C. The Modification of Standard to section 4.27(D)(5) Density/Intensity in E Zone is justified by the applicable standards in 2.8.2(H). The granting of the Modifications would not be detrimental to the public good and: The request satisfies Criteria (2.8.2(H)(4): The plan as submitted will not diverge from the standards of the Land Use Code that are authorized by this Division to be modified except in a nominal, inconsequential way when considered from the perspective of the entire development plan, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. This is because the E zone parcel is a small portion of the entire development, and the reduced density in the E zone has a nominal effect on the reduction of density over the entire development plan, with the development plan providing an additional 21 dwelling units more than the minimum required overall, with a resulting density that is over the minimum required. The overall density achieved continues to advance the purposes of the Land Use Code as contained in Section 1.2.2, specifically: 1.2.2(K) – fostering a more rational pattern of relationship among residential, business and industrial uses for the mutual benefit of all. Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 17 D. The Staff finds that the request for the Modification of Standard to Section 4.27(B)(3)(a)(1) Single-Family lot size is justified by the applicable standards in 2.8.2(H). The granting of the Modifications would not be detrimental to the public good, and: 1) The request satisfies Criteria (2.8.2(H)(1): The plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested. This is because the increase in lot area for the one lot is minimal, and the proposed lot size promotes the general purpose of the standard in a manner that is equal to the purpose of the standard; and 2) The request satisfies Criteria (2.8.2(H)(4): The plan as submitted will not diverge from the standards of the Land Use Code that are authorized by this Division to be modified except in a nominal, inconsequential way when considered from the perspective of the entire development plan, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. This is because the increase in lot area for the one lot is nominal, with the overall development area in the E zone maintaining an average lot size of 5,874 square feet, in conformance with the standard. The overall average lot size achieved continues to advance the purposes of the Land Use Code as contained in Section 1.2.2, specifically: 1.2.2(K) – fostering a more rational pattern of relationship among residential, business and industrial uses for the mutual benefit of all. E. The P.D.P. complies with the process located in Division 2.2 – Common Development Review Procedures for Development Applications of Article 2 – Administration. F. The P.D.P. complies with relevant standards located in Article 3 – General Development Standards. G. The P.D.P. complies with relevant standards located in Division 4.5, Low Density Mixed-Use Neighborhood (L-M-N) of Article 4 – Districts. H. The P.D.P. complies with relevant standards located in Division 4.27, Employment (E) of Article 4. Spring Creek Farms North, Fourth Filing, PDP #130014 Planning & Zoning Hearing December 12, 2013 Page 18 I. The P.D.P. continues to comply with the Spring Creek Farms North Overall Development Plan. RECOMMENDATION: Approval of Spring Creek Farms North, Fourth Filing Project Development Plan, PDP #130014, and Modifications of Standard to Sections 3.2.3(C) Solar-Oriented Residential Lots, 4.27(D)(2) Secondary Uses, 4.27(D)(5) Density/Intensity, 4.27(B)(3)(a)(1) Single- Family maximum lot size in the Employment zone. ATTACHMENTS: 1. Statement of Planning Objectives 2. Applicant’s Modification Requests 3. Neighborhood Meeting Summary 4. Letter from Union Pacific Railroad 5. Site and Landscape Plan 6. Plat 7. Utility Plans 8. Approved O.D.P. 9. Transportation Impact Study - summary