Loading...
HomeMy WebLinkAboutSTONER SUBDIVISION, LOT 2 MAJOR AMENDMENT - OBERMANN RESIDENCE - FDP130045 - REPORTS - RECOMMENDATION/REPORTITEM NO _MJA_#130045_ MEETING DATE _12-5-2013____ ____ STAFF _Holland__________ HEARING OFFICER Planning Services 281 N College Ave – PO Box 580 – Fort Collins, CO 80522-0580 fcgov.com/developmentreview/ 970.221.6750 STAFF REPORT PROJECT: Stoner Subdivision Major Amendment MJA #130045 APPLICANT: Aubrey Carson Carson Design Studio LLC 413 Cormorant Ct. Fort Collins, CO 80525 OWNER: Greg and Kathy Obermann 2215 45 th Avenue Greeley, CO 80634 PROJECT DESCRIPTION: This is a request to consider a Major Amendment to the two lot Stoner Subdivision P.D.P. The project proposes to amend the previously approved building footprint and building elevations for the approved single-family detached dwelling on Lot 2. The applicant proposes a two-story single family residence with plans that show 2,051 total building square feet on the 6,667 square foot lot. The property is located at 1017 W. Magnolia Street and is in the N-C-L, Neighborhood Conservation, Low Density zone district. The amendment is proposed for Lot 2 only. RECOMMENDATION: Denial EXECUTIVE SUMMARY: The approval of the Stoner Subdivision Major Amendment MJA #130045 complies with the process located in Division 2.2 – Common Development Review Procedures for Development Applications of Article 2 – Administration. Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 2 The approval of the Stoner Subdivision Major Amendment MJA #130045 does not comply with the applicable requirements of the City of Fort Collins Land Use Code (LUC), more specifically: • The Major Amendment does not comply with all relevant standards located in Division 4.27, Neighborhood Conservation, Low Density District (N-C-L) of Article 4 – Districts. • The Major Amendment does not comply with all relevant standards located in Article 3 – General Development Standards. COMMENTS: 1. Background: The surrounding zoning and land uses are as follows: N: N-C-L; Existing Single-Family Residential S: N-C-L; Existing Single-Family Residential E: N-C-L; Existing Single-Family Residential W: N-C-L; Existing Single-Family Residential The Stoner Subdivision is part of the Kenwood Heights Annexation, June 21, 1924. The annexation consisted of 80 platted lots that were typically 50 feet wide by 140 feet deep. The Stoner Subdivision re-platted two of the Kenwood Heights platted lots, each measuring 50 by 160 feet and included a total of 15,987 square feet The Stoner Subdivision re-plat re-oriented the original Kenwood Heights east/west interior lot line to run north/south to bisect Lots 1 and 2. The Stoner Subdivision was originally approved as a two-lot subdivision through a Type 1 public hearing held May 30th, 2013. Lot 1 of the Stoner Subdivision is addressed as 502 Wayne Street and is located at the southeast corner of Wayne and Magnolia Streets. An existing one-story single family dwelling is located on Lot 1. Two Modifications of Standard to the Land Use Code were approved with the Stoner Subdivision P.D.P. The first Modification addressed Section 4.7(F)(7) which states that no lot may be further subdivided to create a new lot in the rear portion of the existing lot. The second Modification addressed Section 3.6.2(J)(2) which requires that portions of alleys be paved in conjunction with the proposed use on Lot 2. Due to the Modifications requested with the Stoner Subdivision P.D.P., a building elevation and building footprint were approved for Lot 2 as part of the P.D.P. approval. As described in the staff report for the May 30, 2013 P.D.P. hearing, the building design Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 3 approved with the P.D.P. demonstrated compliance with the architectural character for the project in terms of appropriate size, bulk, massing, scale, detail and articulation. 2. Compliance with Applicable Article 4, Neighborhood Conservation, Low Density District N-C-L Standards: A. Section 4.7(A) - Purpose The Neighborhood Conservation, Low Density District is intended to preserve the character of areas that have a predominance of developed single-family dwellings and have been given this designation in accordance with an adopted subarea plan. The proposed Major Amendment is not in compliance with this standard. As described in more detail later in this staff report, elements of the building design are not arranged to control and mitigate the height, scale, mass and bulk in a way that is compatible with architecture in the surrounding area. The resulting proposed design is incompatible, does not achieve sensitivity in maintaining the character of existing development and does not preserve the character of developed single-family dwellings in accordance with the purpose statement of the N-C-L District. B. Section 4.7(B)(2)(a) - Permitted Uses Single-family dwellings are a permitted use in the N-C-L zone, subject to basic development review, provided that the dwelling is on a lot that is part of an approved site specific development plan. Due to the fact that the project proposes a change in character to the approved building footprint and building elevations, a Major Amendment is required. C. Section 4.7(D)(1) – Density The project is in compliance with the minimum lot area ratio of this section requiring that Lot 2 is two and one-half (2 ½) times the total floor area of the proposed building, which is a ratio of 0.4 overall. The approved building footprint for Lot 2 was below the maximum ratio of 0.4, having a floor-to-lot ratio of 0.346. The proposed amended plan has a floor-to-lot ratio of 0.398, which is in conformance with this standard. Section 4.7(D)(1) also requires that the lots be at least 6,000 square feet for single-family dwellings. Lot 2 remains unchanged with 6,667 square feet provided. D. Section 4.7(D)(4) – Accessory Buildings Without Habitable Space: There is an existing garage which will remain on Lot 2 as an accessory building. The existing garage meets the requirement of this section which states that the total floor area of the accessory building shall not exceed 600 square feet. The floor area shown Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 4 for the garage on the approved plan is 590 square feet, meeting the requirements of this Section. The amended plan calculates the existing garage floor area as 576 square feet, also in compliance with the standard. Prior to approval of a building permit, staff may require that the floor area of the garage is verified to resolve this discrepancy. E. Section 4.7(D)(5) – Floor Area Ratio (FAR): This section requires that lots are subject to a maximum FAR of twenty-five hundredths (0.25) on the rear 50% of the lot. The approved FAR for Lot 2 is in compliance with this requirement, with a 0.2 FAR. The proposed amended plan remains in compliance with approximately 744 square feet on the rear 50% of the lot resulting in a 0.22 FAR. F. Section 4.7(E)(1) – Dimensional Standards, Minimum Lot Width This standard requires that each single-family dwelling have a minimum lot width of 40 feet. Lot 2 is 72 feet in width and remains unchanged from the approved plan. G. Section 4.7(E)(2) – Dimensional Standards, Minimum Front Yard Setback This standard requires that the minimum front yard setback be 15 feet and that the setbacks from garage doors to the backs of public walks be at least 20 feet. The proposed amendment continues to comply with these setback standards. For the existing house on Lot 1, Wayne Street is considered the front setback, due to the fact that the front door faces Wayne Street. For Lot 2, Magnolia Street is considered the front. H. Section 4.7(E)(3) – Dimensional Standards, Minimum Rear Yard Setback The rear yard standard requires a minimum rear yard setback of 15 feet, and the standard does not specify different setbacks for principal and accessory buildings. A 15 foot setback is required for all buildings. The existing detached garage on Lot 2 has a reduced setback that is less than the standard 15 feet. The reduced setback is considered an existing non-conformance, and is permitted provided that the garage building is not altered to further reduce the non-conformance. This is addressed in Division 1.2.4 of the Land use Code, which states: “Except as hereinafter provided, no building, structure or land shall be used and no building or structure or part thereof shall be erected, constructed, reconstructed, altered, repaired, moved or structurally altered except in conformance with the regulations herein specified for the district in which it is located, nor shall a yard, lot or open space be reduced in dimensions or area to an amount less than the minimum requirements set forth herein or to an amount greater than the maximum requirements set forth herein”. Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 5 I. Section 4.7(E)(4) – Dimensional Standards, Minimum Side Yard Setback The side yard setback standard requires a minimum 5 feet for all interior side yards and 15 feet on the street side of any corner lot. The standard does not specify different side setbacks for principal and accessory buildings. The approved building footprint is set back approximately 12.5 feet on the west facing Lot 1 and 17.5 feet on the east facing the alley. The proposed amended building footprint proposes a setback of 5 feet on the west facing Lot 1 and 5 feet on the east facing the alley, which is in compliance with the minimum standard. No changes are proposed to the existing garage setback with this major amendment. For Lot 1, the existing single-family dwelling has a reduced setback that is less than the 15 feet typically required for a street-facing side yard. This existing reduced setback is considered an existing non-conformity, and is permitted provided that the building is not altered to further reduce the non-conformity. J. Section 4.7(E)(5) – Dimensional Standards, Maximum Building Height This standard sets the maximum building height for the N-C-L zone as 2 stories; the amended project remains in compliance with this standard. K. Section 4.7(F)(1) – Development Standards, Building Design The proposed amended project remains in compliance with all applicable building design standards of this section, which require that buildings be constructed at right angles to the lot, that the primary entrance be located along the front wall of the building, that accessory buildings be located at least 10 feet behind the principal building, that the second floor not overhang the lower front or side of the building, that the front porch proposed is limited to one story, and that the roof pitch is between 2:12 and 12:12. The amended building plan contains a 2 nd story open porch on the west of the building which overhangs the first floor. Because the porch is not enclosed, it is not part of the second floor area and therefore the porch is not subject to this standard. L. Section 4.7(F)(2)(a) – Development Standards, Building Height The project remains in compliance with the maximum building height limit of 2 stories for the principal dwelling units. This section also requires that the detached garage, which is an accessory building with no habitable space, have a maximum height of 20 feet and an eave height that does not exceed 10 feet. No height alterations to the existing garage are proposed. These standards would only apply to the existing garage if it is proposed to be altered in a way that would affect the standard. Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 6 M. Section 4.7(F)(4) – Development Standards, Landscape/Hardscape Material This standard requires that not more than 40% of the front yard be covered with inorganic material, and the project remains in compliance with this standard. N. Section 4.7(F)(7) – Development Standards, Subdividing of Existing Lots This standard states that no existing lot may be further subdivided in such manner as to create a new lot in the rear portion of the existing lot. A Modification of Standard is approved with the P.D.P. to address this standard for Lots 1 and 2. 3. Compliance with Article Three – General Development Standards: The following General Development Standards are applicable for the proposed amendment to the Stoner Subdivision. A. Section 3.2.1 – Landscaping and Tree Protection The project remains in compliance with this Section. The approved plans provide for two new street trees, with a caliper size that exceeds the minimum requirements, in order to provide adequate replacement for existing trees that are shown to be removed. No additional trees are proposed to be removed with this amendment. B. Section 3.2.2(K)(1)(c) – Required Off-Street Parking The project continues to provide at least one off-street parking space per lot, which is in compliance with this standard. C. Section 3.5.1(A)(B)(C) Building and Project Compatibility The purpose of this Section is to ensure that the physical and operational characteristics of proposed buildings and uses are compatible when considered within the context of the surrounding area. The General Standard of this section states that: New developments in or adjacent to existing developed areas shall be compatible with the established architectural character of such areas by using a design that is complementary. In areas where the existing architectural character is not definitively established, or is not consistent with the purposes of this Land Use Code, the architecture of new development shall set an enhanced standard of quality for future projects or redevelopment in the area. Compatibility shall be achieved through techniques such as the repetition of roof lines, the use of similar proportions in building mass and outdoor spaces, similar relationships to the street, similar window and door patterns, and/or the use of building materials Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 7 that have color shades and textures similar to those existing in the immediate area of the proposed infill development. Brick and stone masonry shall be considered compatible with wood framing and other materials. Architectural compatibility (including, without limitation, building height) shall be derived from the neighboring context. The predominant character of the surrounding architectural context can be described as follows: • One and two-story single family detached residences with architectural styles that are varied, including eclectic elements of colonial, tudor and craftsman revival styles mixed with minimal traditional and ranch style houses. • The scale, height, mass and bulk of the surrounding architecture is defined by simple overall forms and building outlines. The use of a single simple primary building shape with one primary side gable roof or a single primary front-facing gable or hip roof is typical of the area. Overall house forms are typically defined by one primary roof element with one or two roof elements that are clearly secondary in hierarchy and scale. • The majority of houses are one-story, or if two-story, the floor area of the second story is integrated into the primary roof form, with a minimal use of second-story vertical walls and roof eaves above second-story windows. • Windows and roof elements used with second story areas are complementary with the overall scale and form of the homes, and are typically secondary roof projections such as shed or gable dormers that do not dominate the overall form of the buildings. • A simple material palette is typical, with wood lap siding mixed with either brick, stone or stucco. The approved project provides a building design which demonstrates compliance with the established architectural context in the area, providing appropriate building height size, scale, mass and bulk to achieve compatibility with the area. Compatible aspects of the approved building design include: • The primary elements of the proposed architecture – the overall outline of the home, the use of gables and hip roof elements, and the use of second-story elements that are integrated into the roof line – are designed with a moderate size, bulk, and massing that provides an appropriate transition and compatible fit with existing homes on the block. Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 8 • An appropriate number of secondary elements such as bay windows, porch elements and roof dormers are provided that are appropriate in size, scale and proportion so that these elements do not overpower the overall building form while providing visual interest and articulated massing on all sides of the home. • Architectural detailing is provided through the use of building projections and recesses that are appropriately scaled, stepping down at interior lot lines to provide transition with adjacent lots. • A mix of materials is used with lap siding, shake siding, and large windows that provide a traditional design element that fits the pattern of surrounding residences. • The building footprint is set back from the adjacent property lines approximately 12.5 feet on the west facing Lot 1 and 17.5 feet on the east facing the alley, helping which provides additional space to transition the mass and bulk of the two-story building from the adjacent one-story homes to the east and west. The proposed major amendment to the approved building design does not comply with the building and compatibility standards of this section in terms of scale, height and massing. Compatibility is defined in Article 5 of the LUC: Compatibility shall mean the characteristics of different uses or activities or design which allow them to be located near or adjacent to each other in harmony. Some elements affecting compatibility include height, scale, mass and bulk of structures. Other characteristics include pedestrian or vehicular traffic, circulation, access and parking impacts. Other important characteristics that affect compatibility are landscaping, lighting, noise, odor and architecture. Compatibility does not mean "the same as." Rather, compatibility refers to the sensitivity of development proposals in maintaining the character of existing development. • The proposed design does not achieve compatibility with the homes near or adjacent to the project. The proposed design contains a significant amount of competing building forms, causing the overall bulk and massing to be inconsistent with the character of adjacent one-story homes as well as nearby homes. A single primary building form is not clearly defined, and the multiple forms used do not have sufficient hierarchy within the forms to keep the overall massing from appearing out of scale with homes in the area. • The second story has no floor area that is contained within the roof line of the first story, which is a predominant characteristic of the architecture in the area. The significant quantity and location of competing wall and roof planes used with Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 9 the design is inconsistent with the simple wall and roof forms of nearby architecture. The second story floor area is defined by vertical walls that extend to the top of the second-story windows, and this floor area extends over a large portion of the first story, adding to the inconsistently large bulk and mass of the building. The overall affect is a second story that is not secondary to an overall primary form, and appears as a dominant form on top of another dominant form, which is inconsistent with the architectural context in the area. Elements of the building design are not arranged to control the height, scale, mass and bulk in a way that is compatible with architecture in the surrounding area. The resulting proposed design is incompatible, does not achieve sensitivity in maintaining the character of existing development and does not preserve the character of developed single-family dwellings in accordance with the purpose statement of the N-C-L District. D. Section 3.5.2(D)(3) – Setbacks for alley-accessed garages This standard requires that garages that are accessed from an alley be set back a minimum of 8 feet from the alley right of way. The existing garage on Lot 2 exceeds the minimum 8 foot setback and is in compliance with this standard. This standard is in addition to other applicable setback standards for side, rear, and front setbacks that are listed in Section 4.7(E) which are specific to the project’s zone district. E. Section 3.6.2(J)(2) – Public Alleys, Design Construction Requirements This standard requires that the public alley frontage of this project be paved in conformance with the Larimer County Urban Area Street Standards. A Modification of Standard was approved with the Stoner Subdivision P.D.P. exempting the approved project from this requirement so that the alley could remain unpaved. The major amendment does not propose changes to the landscape, utility, grading or drainage details of the approved plans. Two conditions of approval with the Subdivision P.D.P. were addressed with the approved plans: 1. A 10 foot minimum site distance triangle shall be provided per the Larimer County Urban Area Street Standards within Lot 2 where the alley intersects with the street right of way. All existing shrubs shall be removed from Lot 2 within the site distance triangle. All existing shrubs located on Lot 2 adjacent to the alley right of way shall be removed. 2. A horizontal and vertical design for the 20 foot alley right of way along the east frontage of Lot 2 shall be included as part of the Final Development Plan documents. The design shall provide a 20 foot all-weather roadway surface, crowned at the right of way centerline with a drainage swale on both sides of the roadway surface. Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 10 4. Neighborhood Meeting: The Land Use Code does not require a neighborhood meeting for this major amendment and the applicant chose not to conduct a formal meeting. 5. Findings of Fact / Conclusion: In reviewing and evaluating the Stoner Subdivision Major Amendment, staff makes the following findings of fact and conclusions: A. The Major Amendment complies with the process located in Division 2.2 – Common Development Review Procedures for Development Applications of Article 2 – Administration. B. The Major Amendment does not comply with all relevant standards located in Division 4.27, Neighborhood Conservation, Low Density District (N-C-L) of Article 4 – Districts. The project fails to comply with Section 4.7(A) – Purpose, because elements of the building design are not arranged to control the height, scale, mass and bulk in a way that is compatible with architecture in the surrounding area. The resulting proposed design is incompatible, does not achieve sensitivity in maintaining the character of existing development and does not preserve the character of developed single-family dwellings in accordance with the purpose statement of the N-C-L District. C. The Major Amendment does not comply with all relevant standards located in Article 3 – General Development Standards. The project fails to comply with Sections 3.5.1(A)(B)(C) of Building and Project Compatibility, because the proposed design is incompatible in mass, bulk, and scale with the homes near or adjacent to the project. The proposed design contains a significant amount of competing building forms, causing the overall bulk and massing to be inconsistent with the character of adjacent one-story homes as well as nearby homes. A single primary building form is not clearly defined, and the multiple forms used do not have sufficient hierarchy within the forms to keep the overall massing from appearing out of scale with homes in the area; and The second story has no floor area that is contained within the roof line of the first story, which is a predominant characteristic of the architecture in the area. The significant quantity and location of competing wall and roof planes used with the design are not consistent with the simple wall and roof forms of nearby architecture. The second story floor area is defined by vertical walls that extend to the top of the second-story windows, and this floor area extends over a large Stoner Subdivision Major Amendment MJA/FDP130045 Administrative Hearing 12-5-2013 Page 11 portion of the first story, adding to the inconsistently large bulk and mass of the building. The overall affect is a second story that is not secondary to an overall primary form, and appears as a dominant form on top of another dominant form, which is inconsistent with the architectural context in the area. Elements of the building design are not arranged to control and the height, scale, mass and bulk in a way that is consistent with architecture in the surrounding area. The resulting proposed design is incompatible, does not achieve sensitivity in maintaining the character of existing development. RECOMMENDATION Staff recommends denial of the Stoner Subdivision Major Amendment MJA 130045. ATTACHMENTS 1. Stoner Subdivision proposed Major Amendment Site Plan 2. Stoner Subdivision proposed Major Amendment Building Elevations 3. Stoner Subdivision proposed Major Amendment Hearing Notice 4. Stoner Subdivision approved Site, Landscape and Utility Plan with half-tone linework visible 5. Stoner Subdivision approved signed Site, Landscape and Utility Plan Mylar scan 6. Stoner Subdivision approved Building Elevations 7. Stoner Subdivision approved signed Plat Mylar scan X X VAULT ELEC CONTROL IRR CONTROL IRR �.�. CONTROL IRR � � � � ELEC � BRKR CONTROL IRR AC WW WW WW WW � � E E E E / / / / / / / / / / / / ALLEY ��� 13 ����� 5 ������� ������� 15' BUILDING SETBACK N00° 25' 42.20"E 99.99' S89° 39' 14.95"E 93.14' S00° 20' 45.05"W 99.99' N89° 39' 25.06"W 93.29' S89° 39' 14.95"E 66.84' S00° 31' 41.82"W 99.98' N89° 39' 25.06"W 66.52' LOT 2 6667 S.F. LOT 1 9320 S.F. 6' UTILITY EASEMENT 5' BUILDING SETBACK 4.5' PARKWAY AT INTERSECTION PROPOSED 4.5' SIDEWALK Drawing No. Scale Sheet Scale EV-5 12 of Drawing Title Project Title Elevations 1 Front and Right The Atlantic Front & Right Elevation 502 Wayne Consultant Design Firm T2 Structural Engineering Energy Logic (Energy Cert.) Jamestown Builders 3003 E. Harmony Rd., 4th Floor Fort Collins, CO 80528 Designed By Drawn By Checked By Reviewed By Submitted By Project Manager Date Revision Project ID Drawing Code CAD File Name Plot Date Aaron Everitt AE Anne Marks JTB 4/12/12 Revision The Atlantic Drawing Code Atlantic Master.vwx 00/00/00 No. Date Issue Notes 1 1 2 2 3 3 4 4 5 5 6 6 7 7 A A B B C C D D Drawing No. Scale Sheet Scale EV-6 12 of Drawing Title Project Title Elevations 1 Back and Left The Atlantic Back & Left Elevations 502 Wayne Consultant Design Firm T2 Structural Engineering Energy Logic (Energy Cert.) Jamestown Builders 3003 E. Harmony Rd., 4th Floor Fort Collins, CO 80528 Designed By Drawn By Checked By Reviewed By Submitted By Project Manager Date Revision Project ID Drawing Code CAD File Name Plot Date Aaron Everitt AE Anne Marks JTB 4/12/12 Revision The Atlantic Drawing Code Atlantic Master.vwx 00/00/00 No. Date Issue Notes 1 1 2 2 3 3 4 4 5 5 6 6 7 7 A A B B C C D D E E REAR EXTERIOR ELEVATION -option one SCALE: 1/4" = 1' - 0" LEFT EXTERIOR ELEVATION -option one SCALE: 1/4" = 1' - 0" 6:12 Pitch deck 6 12 4 12 10:12 Pitch 1'-2 1/8" 9'-1 1/8" 1'-0 5/8" 8'-1 1/8" top of foundation Unfinished floor unfinished floor Plate line Plate line 4 12 6 12 10 12 6:12 Pitch 6:12 Pitch 4 12 4 12 4:12 Pitch Stoner Subdivision E E SCALE: 1/4" = 1' - 0" RIGHT EXTERIOR ELEVATION -option one SCALE: 1/4" = 1' - 0" Front EXTERIOR ELEVATION -option one 6:12 Pitch Deck 6 12 10:12 Pitch 4 12 5/4x10 Band 5/4x10 Band 6x6 posts with siding wrap & 5/4"x6" trim collars 1'-2 1/8" 9'-1 1/8" 1'-0 5/8" 8'-1 1/8" top of foundation Unfinished floor unfinished floor Plate line Plate line 4 12 6 12 diamond detail with design on house. fascia design on front part of eave like Schilling model 4 12 flat soffits on entire house 6 12 Concrete Porch deck 10 12 6:Pitch12 Pitch 6:12 4 12 4 12 Stoner Subdivision 5.5' PARKWAY PROPOSED 4.5' SIDEWALK PROPOSED 10.7' PARKWAY S W 10' DRAINAGE & UTILITY EASEMENT PROPOSED 4.5' SIDEWALK 15' BUILDING SETBACK MAGNOLIA STREET WAYNE STREET 4.5' PARKWAY 5' DRAINAGE AND UTILITY EASEMENT BOTH SIDES 15' BUILDING SETBACK 15' BUILDING SETBACK CITY PARK LAKE X X VAULT ELEC CONTROL IRR CONTROL IRR �.�. CONTROL IRR � � � � ELEC � BRKR CONTROL IRR AC WW WW WW WW � � E E E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / MAGNOLIA STREET WAYNE STREET ��� 13 ����� 5 ������� ������� FFE=19.69 FFE=22.15 XS#: 6546 5019 NGVD 29 XS#: 6681 XS#: 6810 LOT 2 FG=21.64 TF=22.31 SEE HC RAMP GRADING DETAIL THIS SHEET SEE DRIVEWAY GRADING DETAIL THIS SHEET LOT 1 VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 NORTH No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: JULY 3, 2013 PROJECT: 358-002 Sheet Of 1 Sheets STONER SUBDIVISION T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 07/03/13 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� S1 SITE PLAN A. Boese A. Boese 1" = 20' AS A REPLAT OF LOTS 14 AND 15, BLOCK 5, KENWOOD HEIGHTS LOCATED IN THE SOUTHWEST QUARTER OF SECTION 11, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6th P.M. CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO STONER SUBDIVISION VICINITY MAP GENERAL NOTES: 1.THE FINAL PLANS ARE INTENDED TO SHOW THE GENERAL CHARACTER OF THE BUILDING ELEVATIONS AND FOOTPRINT FOR LOT 2. BUILDING PLANS FOR LOT 2 SUBMITTED AT THE TIME OF BUILDING PERMIT APPLICATION MAY VARY FROM THE FINAL PLANS, PROVIDED THAT THE GENERAL CHARACTER OF THE BUILDING ELEVATIONS AND FOOTPRINT IS SIMILAR AND THE PLANS ARE IN COMPLIANCE WITH THE APPLICABLE CODE REQUIREMENTS IN EFFECT AT THE TIME OF THIS PROJECT SUBMITTAL. AT THE TIME OF BUILDING PERMIT, BUILDING PLANS SHALL BE REVIEWED FOR COMPLIANCE WITH THE PLANS AND ELEVATIONS INCLUDED WITH THE FINAL PLANS. THE DIRECTOR SHALL DETERMINE WHETHER THE APPROVAL OF VARIATIONS FROM THESE PLANS SHALL BE PERMITTED AS PART OF THE BUILDING PERMIT OR MINOR AMENDMENT OR MAJOR AMENDMENT TO THESE PLANS. 2.ALL HARD SURFACES FROM HOUSE, GARAGE, AND DRIVEWAY ON LOT 2 DRAIN TO MAGNOLIA AND/OR THE ALLEY. 3.REFER TO SITE PLAN TABULATIONS FOR THE APPROVED BUILDING ELEVATIONS FOR THIS PLAN. BUILDING ELEVATIONS SHALL BE POSITIONED IN THE BUILDING ENVELOPE IN ACCORDANCE WITH THE SETBACK AND BUILDING HEIGHT REQUIREMENTS IN LAND USE CODE SECTION 4.7(E). 4.EXISTING SANITARY SERVICE FOR LOT 1 TO BE RE-LOCATED THROUGH 10' UTILITY EASEMENT NORTH OF THE EXISTING GARAGE. WATER AND SEWER SERVICES ARE PROPOSED FOR LOT 2. CONTRACTOR SHALL COORDINATE WITH ADJACENT PROPERTY OWNER REGARDING REPLACEMENT AND SERVICE OUTAGE. CONTRACTOR SHALL NOTIFY CITY OF FORT COLLINS WATER/WASTEWATER DEPARTMENT PRIOR TO STARTING WORK. 5.A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED WITHIN THE PUBLIC RIGHT-OF-WAY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT MAY RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. TREE PRUNING AND REMOVAL WORK TO BE PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORIST WHERE REQUIRED BY CODE. 6.PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDING THE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT SHALL BE NO MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN. DEVELOPER/APPLICANT OWNER JAMESTOWN BUILDERS II LLC 3003 EAST HARMONY ROAD, SUITE 400 FORT COLLINS, COLORADO 80528 SITE, LANDSCAPE AND UTILITY PLAN PROJECT LOCATION MULBERRY SHIELDS MAGNOLIA LEGEND: EXISTING ELECTRIC METER EXISTING CURB STOP EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING LIGHT POLE EXISTING CURB & GUTTER PROPOSED LOTLINE EASEMENT LINE CONTROL IRR C S E G PROPERTY BOUNDARY ELEC BRKR AC C.O. WW EXISTING AC UNIT EXISTING ELECTRIC BREAKER EXISTING CLEAN OUT EXISTING WINDOW WELL VAULT ELEC EXISTING ELECTRIC BOX PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 2.0% EXISTING SPOT ELEVATION EXISTING TREES TO REMAIN EXISTING FENCE X EXISTING SHRUBS TO REMAIN (33.43) GRADING AND DRAINAGE PLAN EXISTING SHRUBS TO BE REMOVED WAYNE BUILDING ENVELOPE OWNER'S CERTIFICATION THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. _________________________ ________ OWNER DATE THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS ______DAY OF ________A.D._______BY _________________________________ (PRINT NAME) AS ______________________________ MY COMMISION EXPIRES: _______________ WITNESS MY HAND AND OFFICIAL SEAL _________________ __________________ NOTARY PUBLIC ADDRESS PLANNING CERTIFICATE APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES (CDNS) OF THE CITY OF FORT COLLINS, COLORADO ON THIS DAY OF , 20 . DIRECTOR OF CDNS PROPERTY DESCRIPTION: BEING A REPLAT OF LOTS 14 AND 15, BLOCK 5, KENWOOD HEIGHTS LOCATED IN THE SOUTHWEST QUARTER OF SECTION 11, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, MORE PARTICULARLY DESCRIBED AS FOLLOWS: CONSIDERING THE NORTH LINE OF BLOCK 5, KENWOOD HEIGHTS AS BEARING SOUTH 89 39' 15" EAST, AND WITH ALL BEARINGS CONTAINED HEREIN RELATIVE THERETO, BEGINNING AT THE NORTHWEST CORNER OF SAID BLOCK 5; THENCE, SOUTH 89° 39' 15" EAST, 159.98 FEET; THENCE, SOUTH 00° 31' 42" WEST, 99.98 FEET; THENCE, NORTH 89° 39' 25" WEST, 159.80 FEET; THENCE, NORTH 00° 25' 42" EAST, 99.99 FEET TO THE POINT OF BEGINNING, CONTAINS 15,987 SQUARE FEET OR 0.367 ACRES, MORE OR LESS. SITE PLAN TABULATIONS EXISTING ZONING: NEIGHBORHOOD CONSERVATION, LOW DENSITY DISTRICT GROSS LAND AREA SF AC REAR 50% LOT 1 9320 0.214 4660 LOT 2 6667 0.153 3333 TOTAL GROSS AREA 15987 0.367 7993 TOTAL DWELING UNITS 2 OVERALL DENSITY (UNITS/ACRE) 5.4 DENSITY CALCULATIONS SF REAR 50% LOT 1 TOTAL FLOOR AREA 2184 519 MINIMUM LOT AREA, 2.5 X FA = 5460 - REAR 50% FLOOR AREA RATIO - 0.11 LOT 2 PRINCIPAL BUILDING 1212 81 SECOND FLOOR AREA 504 - GARAGE FLOOR AREA 590 590 TOTAL FLOOR AREA 2306 671 MINIMUM LOT AREA, 2.5 X FA = 5766 - REAR 50% FLOOR AREA RATIO - 0.20 BUILDING HEIGHT STORIES LOT 2-PRINCIPAL BUILDING 2 LOT 2-SECONDARY BUILDING 1 HOUSING TYPES SINGLE-FAMILY TWO BEDROOM UNITS 2 AREA COVERAGE SF % BUILDING COVERAGE 4329.84 27% DRIVEWAYS 398 2% OPEN SPACE AND LANDSCAPING 10321 65% HARDSCAPE 938 6% PUBLIC STREET RIGHT-OF-WAY 0 0% TOTAL 15987 100% PROPOSED STREET TREE TREE PROTECTION NOTES: 1. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THREE SHOULD BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. {2. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. 3. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 4. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 5. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 6. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 7. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW. 8.}THE DEVELOPER SHALL CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF THE DEVELOPMENT. ALL STREET TREES NEED TO HAVE BEEN INSTALLED AS NOTED ON THE PLAN. FAILURE TO OBTAIN APPROVAL BY THE CITY FORESTER FOR STREET TREE PLANTINGS SHALL RESULT IN A HOLD ON CERTIFICATE OF OCCUPANCY FOR THE DEVELOPMENT. TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 EXISTING 100-YEAR CITY FLOODWAY / / / / / / / / / / / / / / / / / / / / / / / / / / / CROSS-SECTION (CSL) BASE FLOOD ELEVATION (BFE) EXISTING 100-YEAR CITY FLOODPLAIN ELEVATION NGVD 29 (UNADJUSTED) 5000 XS#: 2446 HC RAMP GRADING DETAIL DRIVEWAY GRADING DETAIL SCALE: 1"=10' SCALE: 1"=10' CONCRETE DRIVE TYPICAL SECTION 6" MIN ALLEY CROSS SECTION 2.0% 2.0% APPROVED MODIFICATIONS 1. LAND USE CODE SECTION 4.7(F)(7) MODIFIED TO ALLOW THE SUBDIVISION TO CREATE A NEW LOT IN THE REAR PORTION OF THE EXISTING LOT. 2. LAND USE CODE SECTION 3.6.2(J)(2) MODIFIED TO ALLOW DESIGN OF THE 20-FOOT ALLEY RIGHT-OF WAY ALONG THE EAST FRONTAGE OF LOT 2 TO INCLUDE A 20 FOOT ALL-WEATHER ROADWAY SURFACE, CROWNED AT THE RIGHT-OF-WAY CENTERLINE WITH A DRAINAGE SWALE ON BOTH SIDES OF THE ROADWAY SURFACE. OF STANDARDS: NOTE: ALLEY GRADING MAY BE MODIFIED IN THE FIELD, AS NECESSARY, IN ORDER TO PROVIDE IMPROVED DRAINAGE AND TO ENSURE THAT NEITHER RUNOFF NOR VEHICULAR TRAVEL IS SKEWED TO THE EAST. A FULL 20' WIDE USABLE SECTION SHALL BE MAINTAINED IN ALL CASES. ALLEY SECTION