Loading...
HomeMy WebLinkAboutTHE LEARNING EXPERIENCE @ MIRAMONT OFFICE PARK - PDP - PDP130023 - REPORTS - DRAINAGE REPORTFinal Drainage Report The Learning Experience at Miramont Office Park Prepared for: Adam Rubenstein Rubenstein Real Estate Company C/O The Legend Retail Group 5150 E. Yale Circle, Suite 400 Denver, CO 80222 720-529-2881 arubenstein@legendretailgroup.com Prepared by: Contact: Mark Cevaal, PE mcevaal@redland.com October 4, 2013 Project No. 12026 Final Drainage Report for The Learning Experience at Miramont Office Park 2 ENGINEER CERTIFICATION OF DRAINAGE REPORT “I hereby certify that this report (plan) for the drainage design of The Learning Experience at Miramont Office Park was prepared by me or under my direct supervision in accordance with the provisions of The Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual for the owners thereof.” _______________________________ _____________________________ Mark D. Cevaal, P.E. Date Licensed Professional Engineer State of Colorado No. 33123 Final Drainage Report for The Learning Experience at Miramont Office Park 3 Table of Contents General Location and Description ............................................................................. 4 Project Introduction ............................................................................................. 4 Project Location .................................................................................................. 4 Site Description ................................................................................................... 4 Floodplain Submittal Requirements .................................................................... 5 Drainage Basin and Sub-Basins ............................................................................... 5 Major Basin ......................................................................................................... 5 Sub Basin Descriptions ....................................................................................... 5 Drainage Design Criteria ........................................................................................... 8 Regulations ......................................................................................................... 8 Directly Connected Impervious Area (DCIA) ....................................................... 8 Development Reference Criteria ......................................................................... 8 Hydrologic and Hydraulic Criteria ........................................................................ 8 Floodplain Regulations Compliance .................................................................... 9 Drainage Facility Design ........................................................................................... 9 General Concept ................................................................................................. 9 Specific Details ................................................................................................. 10 Conclusion .............................................................................................................. 11 Compliance with Standards .............................................................................. 11 Drainage Concept ............................................................................................. 11 References ............................................................................................................. 12 Appendix A - Vicinity Map and Soils Map Appendix B - Hydrologic Drainage Calculations Appendix C - Hydraulic Drainage Calculations Appendix D - Reference Documents and Excerpts Appendix E - Proposed Drainage Plan Final Drainage Report for The Learning Experience at Miramont Office Park 4 General Location and Description Project Introduction This PDP Drainage report for Lot 3 of the Miramont Office Park (the Site) covers the development of one 10,000 square foot building with parking and utility infrastructure. The proposed development will modify an existing detention pond to accommodate the new development and provide water quality. The site will be developed into a single story 10,000 square foot daycare building which will utilize an existing parking lot. Improvements include dry and wet utilities, curb and gutter modifications and the building. The building will be utilized as an early childhood development center with a playground. Project Location The project is located in the northeast quarter of Section 1, Township 6 North, Range 69 West of the 6 th Principal Meridian in the City of Fort Collins, Larimer County, State of Colorado. See the Vicinity Map in Appendix A. More specifically it is located within the Miramont Office Park at the northwest corner of Boardwalk Drive and Oakridge Drive. The Site is bounded by existing office buildings to the north, Front Range Baptist Church to the west, Miramont Self-Storage to the south and Boardwalk Drive to the east. There are no major drainage ways or facilities on site. An existing detention pond for the Miramont Office Park is located on Lot 3 and will be modified with this development. Site Description Lot 3 of the Miramont Office Park is 1.614 acres. Currently the west half of the lot is developed as a parking lot with an access drive along the southern boundary. The east half has been overlot graded for a commercial building pad. An existing detention pond is located south of the pad site and serves the entire Miramont Office Park. The undeveloped portions of Lot 3 are covered in native weeds and grasses. The site has relatively mild grades (<2%) and no major drainage ways cross the site. The soils on site are Nunn Clay Loam which is Type C according the NRCS Soil Survey. Type C soils have slow infiltration rates when wet and have a slow rate of water transmission. The proposed site will be developed into a single story early childhood development center. Final Drainage Report for The Learning Experience at Miramont Office Park 5 Floodplain Submittal Requirements The proposed Site is not located within the 100 year floodplain. Drainage Basin and Sub-Basins Major Basin The project site is located within the City of Fort Collins McClellands Basin. No major drainage ways exist on site. According to the Final Drainage and Erosion Control Study of Miramont Office Park dated December 1997 the site is within Basin 202 of the McClelland’s Basin Regional SWMModel. This basin includes the Miramont Office Park, Miramont Self Storage PUD, Front Range Baptist Church and Bank One at Harmony Market. Each of the four sites within this basin will need to provide on-site detention. Currently and in accordance with the Final Drainage and Erosion Control Study of Miramont Office Park on-site detention is provided at the southeast corner of the site. The site receives off-site flows from the church to the west. A swale along this property line collects these flows and directs them to the southeast access drive of the Office Park where they are released to Boardwalk Drive. Sub Basin Descriptions The overall drainage patterns, discharges and basin boundaries have not been modified from the Final Drainage and Erosion Control Study of Miramont Office Park. However, in order to accurately size the pond and associated structures the entire area tributary to the pond had to be analyzed. This analysis results in 10 basins: 7 tributary to the pond and 3 that direct flows off-site. Basin A1 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) A1 2.26 0.64 0.67 0.81 73.2% 2.82 12.50 Basin A1 is the northern portion of the Office Park and is comprised mainly of the developed Lots 1 and 2. This basin is fully developed and contains 4 existing commercial buildings and associated parking. Runoff sheet flows to curb and gutter where it is directed south to design point A1. Currently, a 6’ curb cut directs these flows to the pond. This curb cut will be removed and replaced with a 15’ Type R Inlet. This inlet will direct the flows via a storm sewer to the modified detention and water quality pond. Final Drainage Report for The Learning Experience at Miramont Office Park 6 Basin A2 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) A2 0.65 0.74 0.77 0.87 83.9 1.23 5.05 Basin A2 is the portion of the Lot 3 located west of the proposed building. This basin is fully developed and is comprised entirely of existing parking lot and landscaping. Runoff from this basin will sheet flow to the curb and gutter adjacent to the building. Currently, a two 2-foot wide curb cuts direct these flows to the pond at design point A2. These curb cuts will be removed and replaced with a 10’ Type R Inlet. This inlet will direct the flows via a storm sewer to the modified detention and water quality pond Basin A3 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) A3 0.21 0.07 0.18 0.52 4.2 0.04 1.07 Basin A3 is the modified detention and water quality pond. This basin will remain landscaped. Runoff from this basin will sheet flow directly to the pond. Basin A4 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) A4 0.13 0.11 0.21 0.54 9.7 0.04 0.59 Basin A4 is the playground located east of the proposed building. This basin will contain playground equipment and mulch for the childhood development center. Runoff from this basin will be captured in an underdrain along the eastern edge of the playground. This underdrain will divert the flows to the proposed storm sewer system at design point A4 where they will outfall into the modified detention and water quality pond. Basin A5 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) A5 0.11 0.73 0.75 0.83 90 0.22 0.86 Basin A5 is the west half of the proposed building’s roof. Roof drains will collect flows from the roof and outfall the flow via storm sewer directly into the modified detention and water quality pond. Final Drainage Report for The Learning Experience at Miramont Office Park 7 Basin A6 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) A6 0.11 0.73 0.75 0.83 90 0.22 0.86 Basin A6 is the east half of the proposed building’s roof. Roof drains will collect flows from the roof and outfall the flow via storm sewer directly into the modified detention and water quality pond. Basin A7 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) A7 0.18 0.46 0.51 0.70 54.1 0.19 1.04 Basin A7 is the west half of the roofs of the two existing commercial buildings on Lot 2. Flows from this basin are directed to swale along the western property line that outfalls into a 2’ curb cut at the northwest corner of Basin A2. This is an existing condition that is not changed by the proposed development. This runoff will sheet flow across Basin A2 and enter the new 10’ Type R inlet at design point A2. Basin B1 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) B1 0.38 0.65 0.69 0.83 72.6 0.69 3.05 Basin B1 is the existing access drive along the southern property line of the Miramont Office Park. This access drive sheet flows undetained in Boardwalk Drive. This condition is unchanged from its description in the Final Drainage and Erosion Control Study of Miramont Office Park. Runoff from Front Range Baptist Church discharge into a swale that outfalls into the access drive as is discussed in the previous report as well. Basin B2 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) B2 0.76 0.64 0.68 0.82 72.5 1.06 4.71 Basin B2 is the west half of Boardwalk Drive and its adjacent right of way. A small portion of the on-site areas will sheet flow directly towards the right of way and be Final Drainage Report for The Learning Experience at Miramont Office Park 8 captured by the curb and gutter along Boardwalk Drive. These flows will be directed to the south. Basin B3 Design Point Area (AC) C2 C5 C100 I% Q (2 year) Q (100 Year) B3 0.06 0.57 0.62 0.79 62.2 0.09 0.42 Basin B2 is the south half of the shared access drive with Bank One. This basin will sheet flow undetained to the east and discharge into Boardwalk Drive and is unchanged by the proposed development. Drainage Design Criteria Regulations This report is in compliance with the City of Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual. Directly Connected Impervious Area (DCIA) Since the majority of the site is currently developed as a parking lot; therefore, incorporating directly connected impervious area and LID techniques is not required. The existing detention pond is being modified with the new development to remove the existing concrete low flow channel and replacing it with a grass swale to allow for some infiltration and sediment removal. The addition of the water quality control volume to the pond will also allow time for sediment and impurities to settle out of the runoff. Development Reference Criteria As previously mentioned, the Final Drainage and Erosion Control Study of Miramont Office Park dated December 1997 analyzes the drainage patterns for the site. The overall drainage plan and off-site conditions discussed in this report are still valid and are not changed by the proposed development. Hydrologic and Hydraulic Criteria Hydrologic and hydraulic analysis has been completed to meet the standards of the City of Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual as well as the Urban Drainage Flood Control District (UDFCD) Manual. The Rational Method was used to calculate the flows for each basin. Each basin was analyzed for different land uses and a composite coefficient and imperviousness was Final Drainage Report for The Learning Experience at Miramont Office Park 9 calculated. 2 year run-off coeffecients were taken from Table RO-11 of the Fort Collins Criteria Manual and the frequency factors in Table RO-12 were applied to generate the 5, 10 and 100-year factors. Rainfall intensities for the one-hour storm are listed on Table RA-8 City of Fort Collins. These tables have been included in the appendix for reference. Design storm return periods are 2-year for the minor event and 100-year for the major event. The pond has been sized to detain the 10-year and 100-year storm events. The detention pond and its outfall structure were designed using UD_Detentionv2.32 from Urban Drainage and Flood Control District (UDFCD). The FAA Method was used to size the pond with a 10-year discharge of 0.2 cfs/acre and a 100-year discharge of 0.50 cfs/acre. These release rates were provided by the City of Fort Collins during their Conceptual Project Review. The storm sewer system for the Site is designed to convey the major event, while keeping the hydraulic and energy grade lines below finished grade. Emergency overflow routes have been designed to convey flows to the adjacent streets in the event an inlet becomes obstructed. All of the inlets on site were sized using UD_Inlet v3.12 from UDFCD to handle the 100-year flow without overtopping the adjacent curb and gutter. Floodplain Regulations Compliance No floodplains existing within the proposed study area. Drainage Facility Design General Concept Stormwater in the office park will sheet flow southeast and be directed by curb and gutter to proposed inlets. These inlets will direct flows via storm sewer to the proposed pond. Discharge from the pond will be regulated through a two stage outlet structure that will outfall across the Miramont Self Storage Lot 2 to the south into a concrete drainage pan. This pan will direct the flows to Boardwalk Drive’s curb & gutter. All areas tributary to the existing pond will be discharged into the revised pond. The revised pond has been sized to provide 10-year and 100-year detention plus water quality. Final Drainage Report for The Learning Experience at Miramont Office Park 10 Specific Details The required storage for the detention and water quality pond has been calculated using the FAA method. In its existing condition, the pond has a 2 year release rate of 0.09 cfs and 100 year release rate of 1.80 cfs. These flows were reduced to help compensate for the undetained flows from Boardwalk Drive and the Front Range Baptist Church per the Final Drainage and Erosion Control Study of Miramont Office Park. The release rates for the site as determined by the City of Fort Collins in the conceptual review were set at 0.2 cfs/acre for the 10-year event and 0.50 cfs/acre in the 100-year event. This results in a 10-year release rate of 0.73 cfs and a 100-year release of 1.83 cfs. These values are in line with the previous report and should have no negative impacts on downstream infrastructure The following table provides specific details about the detention and water quality pond. DETENTION/WATER QUALITY POND WQCV REQUIRED = 0.098 AC-FT WQCV PROVIDED 0.149 AC-FT 10-YR VOLUME REQUIRED 0.33 AC-FT +WQCV=0.428 AC-FT 10-YR VOLUME RPROVIDED 0.435 AC-FT 100-YR VOLUME REQUIRED 0.621 AC-FT +WQCV=0.719 AC-FT 100-YR VOLUME PROVIDED 0.750 AC-FT WQCV WATER SURFACE ELEVATION 4999.00 10-YR WATER SURFACE ELEVATION 5000.90 100-YR WATER SURFACE ELEVATION 5002.59 OVERFLOW WEIR WATER SURFACE ELEV. 5002.59 10-YR ALLOWABLE RELEASE RATE - BASIN A 0.2 CFS\AC = 0.73 CFS 100-YR ALLOWABLE RELEASE RATE - BASIN A 0.5 CFS\AC = 1.83 CFS The proposed pond will have a two stage outlet structure with a water quality plate. The water quality plate will consist of one row of five 0.562-inch diameter holes. At the water quality water surface elevation, a 4.27 inch diameter hole will provide the 10 year release. This hole has been sized in conjunction with the water quality plate to restrict the release to 0.73 cfs when the pond is full to the 10-year water surface elevation. The top of the structure will be a single Type C Inlet located at the 10-year water surface elevation. This inlet will collect any volume greater than the 10-year. A restrictor plate has been sized over the structure’s outlet pipe to reduce the flow to 1.83 cfs when the pond is full to the 100-year water surface elevation. The existing emergency spillway for the pond will be maintained. This spillway will provide relief for any volume over the 100-year volume in the pond or if the outlet structure becomes plugged. 1’ of freeboard Final Drainage Report for The Learning Experience at Miramont Office Park 11 is provided above the spillway elevation. The UD_Detention spreadsheet used to size the pond and its structures can be found in the Appendix. A 12” RCP outfall pipe will service the outlet structure and convey the restricted flows to the south. The pipe will cross the access drive and a portion of Lot 2 Miramont Self Storage. The pipe will daylight into a 1’ wide concrete drainage channel. This channel will direct the flows east under the existing walk and into the curb & gutter flowline of Boardwalk Drive. This outfall pipe falls within an existing 15’ drainage and utility easement. Approval has been received from the owner of Lot 2 of Miramont Self Storage to complete the drainage improvements on the property, within the existing easement. A forebay will be provided for the 24” RCP pipe that outfalls into the pond at design point A1. This forebay has been sized to accommodate 1% of the WQCV for its tributary area. It will be 6” deep and discharge through a 4.2-inch wide rectangular weir at a flow equivalent to 2% of the 100 year discharge. The other pond outfalls do not require forebays because their tributary areas are too small. A copy of the UD_BMP spreadsheet for this design can be found in the Appendix. This sheet was only used for forebay design and the other elements remain blank. Maintenance access will be achieved via a gravel access drive along the southern end of the pond. The gravel access drive is graded not to exceed 10% and provides access from the existing driveway to the bottom of the pond and the outlet structure. Both the pond and outfall pipe will be located within the drainage easement on Lot 3 of Miramont Office Park. Conclusion Compliance with Standards The intent of and computations within this report are in compliance with the City of Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual as well as the Urban Drainage and Flood Control District Criteria Manual. It follows the intent of the McClelland Basin Master Drainage Plan and has no impacts on any existing floodplains. Drainage Concept The proposed drainage concepts shown in the report have been design to create no negative impact on existing development or drainage facilities. The proposed improvements will contain storm runoff and discharge it safely and slowly during the design events. The proposed development is in conformance with the McClelland Basin Master Drainage Plan. Final Drainage Report for The Learning Experience at Miramont Office Park 12 References 1. City of Fort Collins, City of Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual, latest online edition. 2. Urban Drainage and Flood Control District, Denver, Colorado, Urban Storm Drainage Criteria Manual, Volume 1-3, latest online edition. 3. The Sear-Brown Group, Final Drainage and Erosion Control Study Miramont Office Park, December 1997 Final Drainage Report for The Learning Experience at Miramont Office Park 13 Appendix A - Vicinity Map Boardwalk Dr Oakridge Dr 73 36 494340 494340 494370 494370 494400 494400 494430 494430 494460 494460 494490 494490 4485510 4485510 4485540 4485540 4485570 4485570 4485600 4485600 4485630 4485630 4485660 4485660 4485690 4485690 4485720 4485720 0 40 80 160 240 Feet 0 10 20 40 60 Meters 40° 31' 20'' 105° 3' 53'' 40° 31' 12'' 105° 3' 52'' 40° 31' 12'' 40° 31' 20'' 105° 4' 0'' 105° 4' 0'' Map Scale: 1:1,160 if printed on A size (8.5" x 11") sheet. Hydrologic Soil Group—Larimer County Area, Colorado (TLE Miramont) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/20/2013 Page 1 of 4 MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Map Units Soil Ratings A A/D B B/D C C/D D Not rated or not available Political Features Cities Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Map Scale: 1:1,160 if printed on A size (8.5" × 11") sheet. The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for accurate map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: http://websoilsurvey.nrcs.usda.gov Coordinate System: UTM Zone 13N NAD83 This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 7, May 1, 2009 Date(s) aerial images were photographed: 8/6/2005 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Hydrologic Soil Group–Larimer County Area, Colorado (TLE Miramont) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/20/2013 Page 2 of 4 Hydrologic Soil Group Hydrologic Soil Group— Summary by Map Unit — Larimer County Area, Colorado (CO644) Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 36 Fort Collins loam, 3 to 5 percent slopes B 0.0 0.2% 73 Nunn clay loam, 0 to 1 percent slope C 4.3 99.8% Totals for Area of Interest 4.3 100.0% Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Hydrologic Soil Group–Larimer County Area, Colorado TLE Miramont Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/20/2013 Page 3 of 4 Component Percent Cutoff: None Specified Tie-break Rule: Higher Hydrologic Soil Group–Larimer County Area, Colorado TLE Miramont Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/20/2013 Page 4 of 4 Final Drainage Report for The Learning Experience at Miramont Office Park 14 Appendix B - Hydrologic Calculations The Learning Experience at Miramont DATE: 12026 RAO MC Paved Landscape Roof Walks LAND USE: Area Area Area Area 2-YEAR COEFF. 0.89 0.04 0.73 0.73 5-YEAR COEFF. 0.90 0.15 0.75 0.75 10-YEAR COEFF. 0.92 0.25 0.77 0.77 100-YEAR COEFF. 0.96 0.50 0.83 0.83 IMPERVIOUS % 100% 0% 90% 90% TOTAL DESIGN DESIGN AREA BASIN POINT (AC) (AC) (AC) (AC) (AC) Cc(2) Cc(5) Cc(10) Cc(100) Impervious % A1 A1 0.99 0.53 0.64 0.10 2.26 0.64 0.67 0.71 0.81 73.2% A2 A2 0.45 0.09 0.05 0.05 0.65 0.74 0.77 0.80 0.87 83.9% A3 A3 0.20 0.01 0.21 0.07 0.18 0.27 0.52 4.2% A4 A4 0.12 0.01 0.13 0.11 0.21 0.31 0.54 9.7% A5 A5 0.11 0.11 0.73 0.75 0.77 0.83 90.0% A6 A6 0.11 0.11 0.73 0.75 0.77 0.83 90.0% A7 A7 0.07 0.11 0.18 0.46 0.51 0.56 0.70 54.1% 1.44 1.02 1.01 0.18 3.65 0.60 0.64 0.68 0.79 68.8% 39.5% 27.9% 27.6% 4.9% 100.0% B1 B1 0.25 0.10 0.03 0.38 0.65 0.69 0.73 0.83 72.6% B2 B2 0.42 0.19 0.14 0.76 0.64 0.68 0.72 0.82 72.5% B3 B3 0.04 0.02 0.06 0.57 0.62 0.67 0.79 62.2% 0.71 0.32 0.00 0.17 1.20 71.9% 59.4% 26.7% 0.0% 13.9% 100.0% 2.15 1.34 1.01 0.35 4.85 0.61 0.65 0.80 69.6% 44.4% 27.6% 20.8% 7.2% 100.0% Calculations assume Type C soils per NRCS SF-1 RUNOFF COEFFICIENTS - DEVELOPED PROJECT NAME: 10/1/2013 PROJECT NUMBER: CALCULATED BY: CHECKED BY: TOTAL STUDY AREA Basin A SUBTOTAL Basin B SUBTOTAL 12026_TLE SF-1, 2 and 3 Developed_FINAL Page 2 of 8 The Learning Experience at Miramont DATE: 12026 RAO MDC FINAL tc DESIGN AREA C5 LENGTH SLOPE T i LENGTH SLOPE Cv Land Surface VEL Tt COMP. TOTAL tc=(L/180)+10 C2 C100 BASIN Ac Ft % Min. Ft. % fps Min. tc LENGTH Min. Min. (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) A1 2.26 0.67 211 1.1% 11.0 288 1.0% 20.0 Paved Areas 2.0 2.4 13.4 499 12.8 13.4 0.64 0.71 A2 0.65 0.77 180 2.0% 6.5 16 1.5% 20.0 Paved Areas 2.4 0.1 6.6 196 11.1 6.6 0.74 0.80 A3 0.21 0.18 22 25.0% 2.7 2.7 22 10.1 5.0 0.07 0.27 A4 0.13 0.21 43 2.0% 8.4 8.4 43 10.2 8.4 0.11 0.31 A5 0.11 0.75 120 2.0% 5.6 5.6 120 10.7 5.6 0.73 0.77 A6 0.11 0.75 120 2.0% 5.6 5.6 120 10.7 5.6 0.73 0.77 A7 0.18 0.51 92 2.0% 8.2 8.2 92 10.5 8.2 0.46 0.56 B1 0.38 0.69 20 2.0% 2.7 102 2.9% 20.0 Paved Areas 3.4 0.5 3.2 122 10.7 5.0 0.65 0.73 B2 0.76 0.68 10 2.0% 1.9 720 0.5% 20.0 Paved Areas 1.4 8.5 10.4 730 14.1 10.4 0.64 0.72 B3 0.06 0.62 90 2.0% 6.7 200 0.9% 20.0 Paved Areas 1.9 1.8 8.5 290 11.6 8.5 0.57 0.67 STANDARD FORM SF-2 - DEVELOPED tc CHECK (URBANIZED BASINS) PROJECT NAME: PROJECT NUMBER: CALCULATED BY: CHECKED BY: Time of Concentration 10/1/2013 SUB-BASIN DATA INITIAL TIME (Ti) TRAVEL TIME (Tt) 1 / 3 0 . 395 ( 1 . 1 ) 1 / 2 S Ti C L − = T L t = 60 V PROJECT NAME: The Learning Experience at Miramont DATE: PROJECT NUMBER: 12026 P1 (1-Hour Rainfall) = 0.82 CALCULATED BY: RAO CHECKED BY: MDC REMARKS DESIGN POINT DESIGN BASIN AREA (AC) RUNOFF COEFF C2 tc (min) C*A(ac) I (in/hr) Q (cfs) tc(min) S(C*A) (ac) I (in/hr) Q (cfs) SLOPE (%) STREET FLOW(cfs) DESIGN FLOW(cfs) SLOPE (%) PIPE SIZE (in) LENGTH (ft) VELOCITY (fps) tt (min) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (21) (22) B1 B1 0.38 0.65 5.00 A4 A4 0.13 0.11 A7 A7 2.70 0.19 0.07 5.00 0.02 2.78 A4 STANDARD FORM SF-3 - DEVELOPED STORM DRAINAGE DESIGN - RATIONAL METHOD 2 YEAR EVENT 10/1/2013 TOTAL RUNOFF STREET PIPE TRAVEL TIME (1) Inlet 1-2 A1 A1 STORM LINE DIRECT RUNOFF PROJECT NAME: The Learning Experience at Miramont DATE: PROJECT NUMBER: 12026 P1 (1-Hour Rainfall) = 1.4 CALCULATED BY: RAO CHECKED BY: MDC REMARKS DESIGN POINT DESIGN BASIN AREA (AC) RUNOFF COEFF C2 tc (min) C*A(ac) I (in/hr) Q (cfs) tc(min) S(C*A) (ac) I (in/hr) Q (cfs) SLOPE (%) STREET FLOW(cfs) DESIGN FLOW(cfs) SLOPE (%) PIPE SIZE (in) LENGTH (ft) VELOCITY (fps) tt (min) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (21) (22) B3 B3 0.06 0.57 8.47 0.49 3.73 1.81 0.04 4.03 0.15 B2 B2 0.76 0.64 10.42 B1 B1 0.38 0.65 5.00 0.25 4.75 1.17 A3 A3 0.21 0.27 5.00 0.06 4.61 0.39 4.75 0.28 A5 A5 0.11 0.77 5.58 0.08 4.61 0.39 A6 A6 0.11 0.77 5.58 0.08 Sum of A2 and A7 (Inlet 1-1) A2 8.2 0.62 4.08 2.51 8.22 0.10 4.08 0.41 A2 A2 0.65 0.80 6.58 0.52 4.39 2.26 A7 A7 0.18 0.56 Sum on A1 and A4 A4 13.4 1.65 3.35 5.53 PROJECT NAME: The Learning Experience at Miramont DATE: PROJECT NUMBER: 12026 P1 (1-Hour Rainfall) = 2.86 CALCULATED BY: RAO CHECKED BY: MDC REMARKS DESIGN POINT DESIGN BASIN AREA (AC) RUNOFF COEFF C100 tc (min) C*A(ac) I (in/hr) Q (cfs) tc(min) S(C*A) (ac) I (in/hr) Q (cfs) SLOPE (%) STREET FLOW(cfs) DESIGN FLOW(cfs) SLOPE (%) PIPE SIZE (in) LENGTH (ft) VELOCITY (fps) tt (min) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (21) (22) 0.05 0.42 0.62 7.61 4.71 8.24 9.70 0.11 9.70 1.07 0.86 3.05 0.86 8.2 0.69 8.33 5.73 1.04 A4 A4 0.13 0.54 8.45 0.07 1.83 6.84 12.50 A4 5.05 13.4 1.90 6.84 12.99 STANDARD FORM SF-3 - DEVELOPED STORM DRAINAGE DESIGN - RATIONAL METHOD 100 YEAR EVENT 41 Table RO-11 Rational Method Runoff Coefficients for Composite Analysis Character of Surface Runoff Coefficient Streets, Parking Lots, Drives: Asphalt 0.95 Concrete 0.95 Gravel 0.5 Roofs 0.95 Recycled Asphalt 0.8 Lawns, Sandy Soil: Flat <2% 0.1 Average 2 to 7% 0.15 Steep >7% 0.2 Lawns, Heavy Soil: Flat <2% 0.2 Average 2 to 7% 0.25 Steep >7% 0.35 (4) A new Section 2.9 is added, to read as follows: 2.9 Composite Runoff Coefficient Drainage sub-basins are frequently composed of land that has multiple surfaces or zoning classifications. In such cases a composite runoff coefficient must be calculated for any given drainage sub-basin. The composite runoff coefficient is obtained using the following formula: ( ) t n i i i A C A C ∑ = = 1 * (RO-8) Where: C = Composite Runoff Coefficient Ci = Runoff Coefficient for Specific Area (Ai) Ai = Area of Surface with Runoff Coefficient of Ci, acres or feet2 n = Number of different surfaces to be considered At = Total Area over which C is applicable, acres or feet2 (5) A new Section 2.10 is added, to read as follows: 42 2.10 Runoff Coefficient Adjustment for Infrequent Storms The runoff coefficients provided in tables RO-10 and RO-11 are appropriate for use with the 2-year storm event. For storms with higher intensities, an adjustment of the runoff coefficient is required due to the lessening amount of infiltration, depression retention, evapo-transpiration and other losses that have a proportionally smaller effect on storm runoff. This adjustment is applied to the composite runoff coefficient. These frequency adjustment factors are found in Table RO-12. Table RO-12 Rational Method Runoff Coefficients for Composite Analysis Storm Return Period (years) Frequency Factor Cf 2 to 10 11 to 25 26 to 50 51 to 100 1.00 1.10 1.20 1.25 Note: The product of C times Cf cannot exceed the value of 1, in the cases where it does a value of 1 must be used (6) Section 3.1 is deleted in its entirety. (7) Section 3.2 is deleted in its entirety. (8) Section 3.3 is deleted in its entirety. (9) A new Section 4.3 is added, to read as follows: 4.3 Computer Modeling Practices (a) For circumstances requiring computer modeling, the design storm hydrographs must be determined using the Stormwater Management Model (SWMM). Basin and conveyance element parameters must be computed based on the physical characteristics of the site. (b) Refer to the SWMM Users’ Manual for appropriate modeling methodology, practices and development. The Users’ Manual can be found on the Environmental Protection Agency (EPA) website (http://www.epa.gov/ednnrmrl/models/swmm/index.htm). (c) It is the responsibility of the design engineer to verify that all of the models used in the design meet all current City criteria and regulations. 4.3.1 Surface Storage, Resistance Factors, and Infiltration Table RO-13 provides values for surface storage for pervious and impervious surfaces and the infiltration rates to be used with SWMM. Table RO-13 also lists the appropriate infiltration decay rate, zero detention depth and resistance factors, or Manning’s “n” values, for pervious and impervious surfaces to be used for SWMM modeling in the city of Fort Collins. 33 (11) Section 4.0 is amended to read as follows: 4.0 Intensity-Duration-Frequency Curves for Rational Method: The one-hour rainfall Intensity-Duration-Frequency tables for use the Rational Method of runoff analysis are provided in Table RA-7 and in Table RA-8. Table RA-7 -- City of Fort Collins Rainfall Intensity-Duration-Frequency Table for Use with the Rational Method (5 minutes to 30 minutes) 2-Year 10-Year 100-Year Duration (min) Intensity (in/hr) Intensity (in/hr) Intensity (in/hr) 5 2.85 4.87 9.95 6 2.67 4.56 9.31 7 2.52 4.31 8.8 8 2.4 4.1 8.38 9 2.3 3.93 8.03 10 2.21 3.78 7.72 11 2.13 3.63 7.42 12 2.05 3.5 7.16 13 1.98 3.39 6.92 14 1.92 3.29 6.71 15 1.87 3.19 6.52 16 1.81 3.08 6.3 17 1.75 2.99 6.1 18 1.7 2.9 5.92 19 1.65 2.82 5.75 20 1.61 2.74 5.6 21 1.56 2.67 5.46 22 1.53 2.61 5.32 23 1.49 2.55 5.2 24 1.46 2.49 5.09 25 1.43 2.44 4.98 26 1.4 2.39 4.87 27 1.37 2.34 4.78 28 1.34 2.29 4.69 29 1.32 2.25 4.6 30 1.3 2.21 4.52 34 Table RA-8 -- City of Fort Collins Rainfall Intensity-Duration-Frequency Table for Use with the Rational Method (31 minutes to 60 minutes) 2-Year 10-Year 100-Year Duration (min) Intensity (in/hr) Intensity (in/hr) Intensity (in/hr) 31 1.27 2.16 4.42 32 1.24 2.12 4.33 33 1.22 2.08 4.24 34 1.19 2.04 4.16 35 1.17 2.0 4.08 36 1.15 1.96 4.01 37 1.16 1.93 3.93 38 1.11 1.89 3.87 39 1.09 1.86 3.8 40 1.07 1.83 3.74 41 1.05 1.8 3.68 42 1.04 1.77 3.62 43 1.02 1.74 3.56 44 1.01 1.72 3.51 45 0.99 1.69 3.46 46 0.98 1.67 3.41 47 0.96 1.64 3.36 48 0.95 1.62 3.31 49 0.94 1.6 3.27 50 0.92 1.58 3.23 51 0.91 1.56 3.18 52 0.9 1.54 3.14 53 0.89 1.52 3.1 54 0.88 1.5 3.07 55 0.87 1.48 3.03 56 0.86 1.47 2.99 57 0.85 1.45 2.96 58 0.84 1.43 2.92 59 0.83 1.42 2.89 60 0.82 1.4 2.86 Final Drainage Report for The Learning Experience at Miramont Office Park 15 Appendix C - Hydraulic Calculations 12026 UD-Inlet_v3.12 2013-06-21, Inlet In Sump 6/21/2013, 3:39 PM Project = Inlet ID = Design Information (Input) MINOR MAJOR Type of Inlet Inlet Type = Local Depression (additional to continuous gutter depression 'a' from 'Q-Allow') alocal = 3.00 3.00 inches Number of Unit Inlets (Grate or Curb Opening) No = 2 2 Water Depth at Flowline (outside of local depression) Ponding Depth = 6.0 6.0 inches Grate Information MINOR MAJOR Length of a Unit Grate Lo (G) = N/A N/A feet Width of a Unit Grate Wo = N/A N/A feet Area Opening Ratio for a Grate (typical values 0.15-0.90) Aratio = N/A N/A Clogging Factor for a Single Grate (typical value 0.50 - 0.70) Cf (G) = N/A N/A Grate Weir Coefficient (typical value 2.15 - 3.60) Cw (G) = N/A N/A Grate Orifice Coefficient (typical value 0.60 - 0.80) Co (G) = N/A N/A Curb Opening Information MINOR MAJOR Length of a Unit Curb Opening Lo (C) = 5.00 5.00 feet Height of Vertical Curb Opening in Inches Hvert = 6.00 6.00 inches Height of Curb Orifice Throat in Inches Hthroat = 6.00 6.00 inches Angle of Throat (see USDCM Figure ST-5) Theta = 63.40 63.40 degrees Side Width for Depression Pan (typically the gutter width of 2 feet) Wp = 2.00 2.00 feet Clogging Factor for a Single Curb Opening (typical value 0.10) Cf (C) = 0.10 0.10 Curb Opening Weir Coefficient (typical value 2.3-3.6) Cw (C) = 3.60 3.60 Curb Opening Orifice Coefficient (typical value 0.60 - 0.70) Co (C) = 0.67 0.67 MINOR MAJOR Total Inlet Interception Capacity (assumes clogged condition) Qa = 10.5 10.5 cfs Inlet Capacity IS GOOD for Minor and Major Storms (>Q PEAK) Q PEAK REQUIRED = 1.8 6.6 cfs INLET IN A SUMP OR SAG LOCATION TLE Miramont #12026 Inlet 1-1 CDOT Type R Curb Opening H-Vert H-Curb W Lo (C) Lo (G) Wo WP Override Depths 12026 Inlet 1-2 UD-Inlet_v3.12 2013-06-21, Inlet In Sump 6/21/2013, 3:43 PM Project = Inlet ID = Design Information (Input) MINOR MAJOR Type of Inlet Inlet Type = Local Depression (additional to continuous gutter depression 'a' from 'Q-Allow') alocal = 3.00 3.00 inches Number of Unit Inlets (Grate or Curb Opening) No = 3 3 Water Depth at Flowline (outside of local depression) Ponding Depth = 4.0 6.2 inches Grate Information MINOR MAJOR Length of a Unit Grate Lo (G) = N/A N/A feet Width of a Unit Grate Wo = N/A N/A feet Area Opening Ratio for a Grate (typical values 0.15-0.90) Aratio = N/A N/A Clogging Factor for a Single Grate (typical value 0.50 - 0.70) Cf (G) = N/A N/A Grate Weir Coefficient (typical value 2.15 - 3.60) Cw (G) = N/A N/A Grate Orifice Coefficient (typical value 0.60 - 0.80) Co (G) = N/A N/A Curb Opening Information MINOR MAJOR Length of a Unit Curb Opening Lo (C) = 5.00 5.00 feet Height of Vertical Curb Opening in Inches Hvert = 6.00 6.00 inches Height of Curb Orifice Throat in Inches Hthroat = 6.00 6.00 inches Angle of Throat (see USDCM Figure ST-5) Theta = 63.40 63.40 degrees Side Width for Depression Pan (typically the gutter width of 2 feet) Wp = 2.00 2.00 feet Clogging Factor for a Single Curb Opening (typical value 0.10) Cf (C) = 0.10 0.10 Curb Opening Weir Coefficient (typical value 2.3-3.6) Cw (C) = 3.60 3.60 Curb Opening Orifice Coefficient (typical value 0.60 - 0.70) Co (C) = 0.67 0.67 MINOR MAJOR Total Inlet Interception Capacity (assumes clogged condition) Qa = 3.9 14.4 cfs Inlet Capacity IS GOOD for Minor and Major Storms (>Q PEAK) Q PEAK REQUIRED = 3.9 14.4 cfs INLET IN A SUMP OR SAG LOCATION TLE Miramont #12026 Inlet 1-2 (Basin A1) CDOT Type R Curb Opening H-Vert H-Curb W Lo (C) Lo (G) Wo WP Override Depths Project: Basin ID: Design Information (Input): Design Information (Input): Catchment Drainage Imperviousness Ia = 68.80 percent Catchment Drainage Imperviousness Ia = 68.80 percent Catchment Drainage Area A = 3.650 acres Catchment Drainage Area A = 3.650 acres Predevelopment NRCS Soil Group Type = C A, B, C, or D Predevelopment NRCS Soil Group Type = C A, B, C, or D Return Period for Detention Control T = 10 years (2, 5, 10, 25, 50, or 100) Return Period for Detention Control T = 100 years (2, 5, 10, 25, 50, or 100) Time of Concentration of Watershed Tc = 13 minutes Time of Concentration of Watershed Tc = 13 minutes Allowable Unit Release Rate q = 0.20 cfs/acre Allowable Unit Release Rate q = 0.50 cfs/acre One-hour Precipitation P1 = 1.40 inches One-hour Precipitation P1 = 2.86 inches Design Rainfall IDF Formula i = C1* P1/(C2+Tc)^C3 Design Rainfall IDF Formula i = C1* P1/(C2+Tc)^C3 Coefficient One C1 = 28.50 Coefficient One C1 = 28.50 Coefficient Two C2 = 10 Coefficient Two C2 = 10 Coefficient Three C3 = 0.789 Coefficient Three C3 = 0.789 Determination of Average Outflow from the Basin (Calculated): Determination of Average Outflow from the Basin (Calculated): Runoff Coefficient C = 0.68 Runoff Coefficient C = 0.79 Inflow Peak Runoff Qp-in = 9.10 cfs Inflow Peak Runoff Qp-in = 21.59 cfs Allowable Peak Outflow Rate Qp-out = 0.73 cfs Allowable Peak Outflow Rate Qp-out = 1.83 cfs Mod. FAA Minor Storage Volume = 14,381 cubic feet Mod. FAA Major Storage Volume = 27,036 cubic feet Mod. FAA Minor Storage Volume = 0.330 acre-ft Mod. FAA Major Storage Volume = 0.621 acre-ft 5 <- Enter Rainfall Duration Incremental Increase Value Here (e.g. 5 for 5-Minutes) Rainfall Rainfall Inflow Adjustment Average Outflow Storage Rainfall Rainfall Inflow Adjustment Average Outflow Storage Duration Intensity Volume Factor Outflow Volume Volume Duration Intensity Volume Factor Outflow Volume Volume minutes inches / hr acre-feet "m" cfs acre-feet acre-feet minutes inches / hr acre-feet "m" cfs acre-feet acre-feet (input) (output) (output) (output) (output) (output) (output) (input) (output) (output) (output) (output) (output) (output) 0 0.00 0.000 0.00 0.00 0.000 0.000 0 0.00 0.000 0.00 0.00 0.000 0.000 5 4.71 0.081 1.00 0.73 0.005 0.075 5 9.62 0.191 1.00 1.83 0.013 0.179 10 3.75 0.128 1.00 0.73 0.010 0.118 10 7.67 0.305 1.00 1.83 0.025 0.279 15 3.15 0.161 0.93 0.68 0.014 0.147 15 6.43 0.383 0.93 1.70 0.035 0.348 20 2.73 0.186 0.83 0.60 0.017 0.170 20 5.57 0.442 0.83 1.51 0.041 0.401 25 2.41 0.206 0.76 0.55 0.019 0.187 25 4.93 0.490 0.76 1.39 0.048 0.442 30 2.17 0.223 0.72 0.52 0.022 0.201 30 4.44 0.529 0.72 1.31 0.054 0.475 35 1.98 0.237 0.69 0.50 0.024 0.213 35 4.04 0.562 0.69 1.25 0.060 0.502 40 1.82 0.249 0.66 0.48 0.027 0.222 40 3.72 0.591 0.66 1.21 0.067 0.525 45 1.69 0.260 0.64 0.47 0.029 0.231 45 3.45 0.617 0.64 1.18 0.073 0.544 50 1.58 0.270 0.63 0.46 0.032 0.238 50 3.22 0.640 0.63 1.15 0.079 0.561 55 1.48 0.278 0.62 0.45 0.034 0.244 55 3.03 0.661 0.62 1.13 0.085 0.575 60 1.40 0.287 0.61 0.44 0.037 0.250 60 2.85 0.680 0.61 1.11 0.092 0.588 65 1.32 0.294 0.60 0.44 0.039 0.255 65 2.70 0.698 0.60 1.10 0.098 0.600 70 1.26 0.301 0.59 0.43 0.042 0.259 70 2.57 0.714 0.59 1.08 0.104 0.610 75 1.20 0.307 0.59 0.43 0.044 0.263 75 2.45 0.729 0.59 1.07 0.111 0.619 80 1.15 0.313 0.58 0.42 0.047 0.267 80 2.34 0.744 0.58 1.06 0.117 0.627 85 1.10 0.319 0.58 0.42 0.049 0.270 85 2.24 0.757 0.58 1.05 0.123 0.634 90 1.05 0.324 0.57 0.42 0.052 0.273 90 2.15 0.770 0.57 1.04 0.129 0.640 95 1.01 0.329 0.57 0.41 0.054 0.275 95 2.07 0.782 0.57 1.04 0.136 0.646 100 0.98 0.334 0.57 0.41 0.057 0.278 100 2.00 0.793 0.57 1.03 0.142 0.651 105 0.94 0.339 0.56 0.41 0.059 0.280 105 1.93 0.804 0.56 1.03 0.148 0.656 110 0.91 0.343 0.56 0.41 0.062 0.282 110 1.87 0.815 0.56 1.02 0.155 0.660 115 0.88 0.348 0.56 0.41 0.064 0.283 115 1.81 0.825 0.56 1.02 0.161 0.664 120 0.86 0.352 0.55 0.40 0.067 0.285 120 1.75 0.835 0.55 1.01 0.167 0.667 125 0.83 0.356 0.55 0.40 0.069 0.286 125 1.70 0.844 0.55 1.01 0.173 0.670 130 0.81 0.359 0.55 0.40 0.072 0.287 130 1.65 0.853 0.55 1.00 0.180 0.673 135 0.79 0.363 0.55 0.40 0.074 0.289 135 1.61 0.861 0.55 1.00 0.186 0.675 140 0.77 0.366 0.55 0.40 0.077 0.290 140 1.56 0.870 0.55 1.00 0.192 0.677 145 0.75 0.370 0.54 0.40 0.079 0.290 145 1.52 0.878 0.54 0.99 0.199 0.679 150 0.73 0.373 0.54 0.40 0.082 0.291 150 1.49 0.886 0.54 0.99 0.205 0.681 155 0.71 0.376 0.54 0.40 0.084 0.292 155 1.45 0.893 0.54 0.99 0.211 0.682 160 0.69 0.379 0.54 0.39 0.087 0.292 160 1.42 0.901 0.54 0.99 0.217 0.683 165 0.68 0.382 0.54 0.39 0.089 0.293 165 1.39 0.908 0.54 0.98 0.224 0.684 170 0.66 0.385 0.54 0.39 0.092 0.293 170 1.35 0.915 0.54 0.98 0.230 0.685 12026 UD-Detention_v2.32 FINAL, Basin 10/1/2013, 2:09 PM Project: Basin ID: Design Information (Input): Width of Basin Bottom, W = ft Right Triangle OR… Length of Basin Bottom, L = ft Isosceles Triangle OR… Dam Side-slope (H:V), Zd = ft/ft Rectangle OR… Circle / Ellipse OR… Irregular (Use Overide values in cells G32:G52) MINOR MAJOR Storage Requirement from Sheet 'Modified FAA': 0.27 0.62 acre-ft. Stage-Storage Relationship: Storage Requirement from Sheet 'Hydrograph': acre-ft. Storage Requirement from Sheet 'Full-Spectrum': acre-ft. Labels Water Side Basin Basin Surface Surface Volume Surface Volume Target Volumes for WQCV, Minor, Surface Slope Width at Length at Area at Area at Below Area at Below for WQCV, Minor, & Major Storage Elevation (H:V) Stage Stage Stage Stage Stage Stage Stage & Major Storage Stages ft ft/ft ft ft ft2 ft2 User ft3 acres acre-ft Volumes (input) (input) Below El. (output) (output) (output) Overide (output) (output) (output) (for goal seek) 4997.00 (input) 0 0.000 0.000 4998.00 0.00 0.00 3,396 1,698 0.078 0.039 WQCV 4999.00 0.00 0.00 6,177 6,485 0.142 0.149 WCQV = 0.098 4999.50 0.00 0.00 6,368 9,621 0.146 0.221 5000.00 0.00 0.00 6,575 12,857 0.151 0.295 Minor 5000.90 0.00 0.00 6,923 18,931 0.159 0.435 10 YEAR = .43 5001.00 0.00 0.00 6,967 19,625 0.160 0.451 5002.00 0.00 0.00 7,747 26,982 0.178 0.619 Major 5002.59 0.00 0.00 11,541 32,672 0.265 0.750 100 YEAR = .719 5003.60 0.00 0.00 11,541 44,328 0.265 1.018 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A 12026 UD-Detention_v2.32 FINAL, Basin 10/1/2013, 2:09 PM Project: Basin ID: STAGE-STORAGE SIZING FOR DETENTION BASINS 4997.08 4998.08 4999.08 5000.08 5001.08 5002.08 5003.08 5004.08 0.00 0.20 0.40 0.60 0.80 1.00 1.20 Stage (ft. elev.) Storage (acre-feet) STAGE-STORAGE CURVE FOR THE POND 12026 UD-Detention_v2.32 FINAL, WQCV 10/1/2013, 2:09 PM Project: Basin ID: WQCV Design Volume (Input): Catchment Imperviousness, Ia = 68.8 percent Diameter of holes, D = 0.562 in. Time to Drain the Pond = 40 hours Catchment Area, A = 3.65 acres Number of holes per row, N = 1 Depth at WQCV outlet above lowest perforation, H = 2 feet OR Vertical distance between rows, h = 4.00 inches Number of rows, NL = 5 Height of slot, H = in. Orifice discharge coefficient, Co = 0.60 Width of slot, W = in. Slope of Basin Trickle Channel, S = 0.010 ft / ft Outlet Design Information (Output): Water Quality Capture Volume (1.0 * (0.91 * I^3 - 1.19 * I^2 + 0.78 * I)), WQCV = 0.270 watershed inches Water Quality Capture Volume (WQCV) = 0.082 acre-feet 1.63 Design Volume (WQCV / 12 * Area * 1.2) Vol = 0.098 acre-feet Outlet area per row, Ao = 0.25 square inches Total opening area at each row based on user-input above, Ao = 0.25 square inches Total opening area at each row based on user-input above, Ao = 0.002 square feet Calculation of Collection Capacity: Stage Row 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 Row 10 Row 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row 21 Row 22 Row 23 Row 23 Σ ft 4997.45 4997.78 4998.12 4998.45 4998.78 Flow (input) 4997.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.00 4997.50 0.0019 0.0000 0.0000 0.0000 0.0000 0.00 4998.00 0.0061 0.0039 0.0000 0.0000 0.0000 0.01 4998.50 0.0085 0.0070 0.0051 0.0019 0.0000 0.02 4999.00 0.0103 0.0092 0.0078 0.0061 0.0039 0.04 4999.50 0.0119 0.0109 0.0097 0.0085 0.0070 0.05 5000.00 0.0132 0.0124 0.0114 0.0103 0.0092 0.06 5000.50 0.0145 0.0137 0.0128 0.0119 0.0109 0.06 5001.00 0.0156 0.0149 0.0141 0.0132 0.0124 0.07 5001.50 0.0167 0.0160 0.0152 0.0145 0.0137 0.08 5002.00 0.0177 0.0170 0.0163 0.0156 0.0149 0.08 5002.50 0.0186 0.0180 0.0174 0.0167 0.0160 0.09 5003.00 0.0195 0.0189 0.0183 0.0177 0.0170 0.09 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A 12026 UD-Detention_v2.32 FINAL, WQCV 10/1/2013, 2:09 PM Worksheet Protected Project: Basin ID: STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET TLE at Miramont #12026 5000.00 5000.50 5001.00 5001.50 5002.00 5002.50 5003.00 5003.50 0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 Stage (feet, elev.) Discharge (cfs) STAGE-DISCHARGE CURVE FOR THE WQCV OUTLET STRUCTURE 12026 UD-Detention_v2.32 FINAL, Restrictor Plate 10/1/2013, 2:09 PM Project: Basin ID: X 1 #1 Vertical #2 Vertical Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input) Orifice Orifice Water Surface Elevation at Design Depth Elev: WS = 5,002.59 feet Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert = 4,996.97 feet Required Peak Flow through Orifice at Design Depth Q = 1.83 1.83 cfs Pipe/Vertical Orifice Diameter (inches) Dia = 12.0 12.0 inches Orifice Coefficient Co = 0.65 0.65 Full-flow Capacity (Calculated) Full-flow area Af = 0.79 sq ft Half Central Angle in Radians Theta = 3.14 rad Full-flow capacity Qf = 9.3 cfs Percent of Design Flow = 508% Calculation of Orifice Flow Condition Half Central Angle (0<Theta<3.1416) Theta = 1.04 rad Flow area Ao = 0.15 sq ft Top width of Orifice (inches) To = 10.32 inches Height from Invert of Orifice to Bottom of Plate (feet) Yo = 0.25 feet Elevation of Bottom of Plate Elev Plate Bottom Edge = 4,997.22 feet Resultant Peak Flow Through Orifice at Design Depth Qo = 1.8 cfs Width of Equivalent Rectangular Vertical Orifice Equivalent Width = 0.60 feet Centroid Elevation of Equivalent Rectangular Vertical Orifice Equiv. Centroid El. = 4,997.10 feet TLE at Miramont #12026 RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES 12026 UD-Detention_v2.32 FINAL, Outlet 10/1/2013, 2:09 PM Project: Basin ID: Design Information (Input): #1 Horiz. #2 Horiz. #1 Vert. #2 Vert. Circular Opening: Diameter in Inches Dia. = 4.27 inches OR Rectangular Opening: Width in Feet W = 2.92 0.60 ft. Length (Height for Vertical) L or H = 2.92 0.25 ft. Percentage of Open Area After Trash Rack Reduction % open = 50 100 100 % Orifice Coefficient Co = 0.65 0.65 0.65 Weir Coefficient Cw = 3.00 Orifice Elevation (Bottom for Vertical) Eo = 5000.90 4,999.00 4,996.97 ft. Calculation of Collection Capacity: Net Opening Area (after Trash Rack Reduction) Ao = 4.26 0.10 0.15 sq. ft. OPTIONAL: User-Overide Net Opening Area Ao = sq. ft. Perimeter as Weir Length Lw = 8.76 ft. OPTIONAL: User-Overide Weir Length Lw = ft. Top Elevation of Vertical Orifice Opening, Top = 4999.36 4997.22 ft. Center Elevation of Vertical Orifice Opening, Cen = 4999.18 4997.10 ft. Horizontal Orifices Vertical Orifices Labels Water WQCV #1 Horiz. #1 Horiz. #2 Horiz. #2 Horiz. #1 Vert. #2 Vert. Total Target Volumes for WQCV, Minor, Surface Plate/Riser Weir Orifice Weir Orifice Collection Collection Collection for WQCV, Minor, & Major Storage Elevation Flow Flow Flow Flow Flow Capacity Capacity Capacity & Major Storage W.S. Elevations ft cfs cfs cfs cfs cfs cfs cfs cfs Volumes (input) (linked) (User-linked) (output) (output) (output) (output) (output) (output) (output) (link for goal seek) 4997.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 4998.00 0.00 0.00 0.00 0.00 0.00 0.00 0.74 0.00 WQCV 4999.00 0.01 0.00 0.00 0.00 0.00 0.00 1.08 0.01 wqcv 4999.50 0.02 0.00 0.00 0.00 0.00 0.29 1.21 0.32 5000.00 0.04 0.00 0.00 0.00 0.00 0.47 1.33 0.51 Minor 5000.90 0.05 0.00 0.00 0.00 0.00 0.68 1.53 0.73 10 year 5001.00 0.06 0.83 7.03 0.00 0.00 0.70 1.55 1.55 5002.00 0.06 30.32 23.32 0.00 0.00 0.87 1.73 1.73 Major 5002.59 0.07 57.74 28.91 0.00 0.00 0.96 1.83 1.83 spillway/100 yr 5003.60 0.08 116.59 36.54 0.00 0.00 1.09 2.00 2.00 0.08 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.09 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.09 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A 12026 UD-Detention_v2.32 FINAL, Outlet 10/1/2013, 2:09 PM Project: Basin ID: TLE at Miramont #12026 STAGE-DISCHARGE SIZING OF THE WEIRS AND ORIFICES (INLET CONTROL) 4997.08 4998.08 4999.08 5000.08 5001.08 5002.08 5003.08 5004.08 0 0.5 1 1.5 2 2.5 Stage (feet, elev.) Discharge (cfs) STAGE-DISCHARGE CURVE FOR THE OUTLET STRUCTURE 12026 UD-Detention_v2.32 FINAL, Spillway 10/1/2013, 2:09 PM Project: Basin ID: 75.96 4.00000 Design Information (input): Bottom Length of Weir L = 6.00 feet Angle of Side Slope Weir Angle = 75.96 degrees Elev. for Weir Crest EL. Crest = 5,002.59 feet Coef. for Rectangular Weir Cw = 3.30 Coef. for Trapezoidal Weir Ct = 2.50 Calculation of Spillway Capacity (output): Water Rect. Triangle Total Total Surface Weir Weir Spillway Pond Elevation Flowrate Flowrate Release Release ft. cfs cfs cfs cfs (linked) (output) (output) (output) (output) 4997.00 0.00 0.00 0.00 0.00 4998.00 0.00 0.00 0.00 0.00 4999.00 0.00 0.00 0.00 0.01 4999.50 0.00 0.00 0.00 0.32 5000.00 0.00 0.00 0.00 0.51 5000.90 0.00 0.00 0.00 0.73 5001.00 0.00 0.00 0.00 1.55 5002.00 0.00 0.00 0.00 1.73 5002.59 0.00 0.00 0.00 1.83 5003.60 20.10 10.25 30.35 32.35 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A 12026 UD-Detention_v2.32 FINAL, Spillway 10/1/2013, 2:09 PM Project: Basin ID: STAGE-DISCHARGE SIZING OF THE SPILLWAY TLE at Miramont Existing Spillway Capacity 0 0.2 0.4 0.6 0.8 1 1.2 4997 4998 4999 5000 5001 5002 5003 5004 0 5 10 15 20 25 30 35 Storage (Acre-Feet) Stage (feet, elev.) Pond Discharge (cfs) STAGE-STORAGE-DISCHARGE CURVES FOR THE POND TOTAL DISCHARGE SPILLWAY DISCHARGE POND STORAGE UD-BMP for Basin 1 and 4, EDB 7/8/2013, 3:42 PM Sheet 1 of 4 Designer: Company: Date: Project: Location: 1. Basin Storage Volume A) Effective Imperviousness of Tributary Area, Ia I a = 69.7 % B) Tributary Area's Imperviousness Ratio (i = Ia / 100 ) i = 0.697 C) Contributing Watershed Area Area = 2.390 ac D) For Watersheds Outside of the Denver Region, Depth of Average d6 = in Runoff Producing Storm E) Design Concept (Select EURV when also designing for flood control) F) Design Volume (1.2 WQCV) Based on 40-hour Drain Time VDESIGN = 0.065 ac-ft (VDESIGN = (1.0 * (0.91 * i 3 - 1.19 * i 2 + 0.78 * i) / 12 * Area * 1.2) G) For Watersheds Outside of the Denver Region, VDESIGN OTHER = ac-ft Water Quality Capture Volume (WQCV) Design Volume (VWQCV OTHER = (d 6*(VDESIGN /0.43)) H) User Input of Water Quality Capture Volume (WQCV) Design Volume VDESIGN USER = ac-ft (Only if a different WQCV Design Volume is desired) I) Predominant Watershed NRCS Soil Group J) Excess Urban Runoff Volume (EURV) Design Volume For HSG A: EURVA = (0.1878i - 0.0104)*Area EURV = ac-f t For HSG B: EURVB = (0.1178i - 0.0042)*Area For HSG C/D: EURVC/D = (0.1043i - 0.0031)*Area 2. Basin Shape: Length to Width Ratio L : W = 2.0 : 1 (A basin length to width ratio of at least 2:1 will improve TSS reduction.) 3. Basin Side Slopes A) Basin Maximum Side Slopes Z = 4.00 ft / ft (Horizontal distance per unit vertical, 4:1 or flatter preferred) 4. Inlet A) Describe means of providing energy dissipation at concentrated inflow locations: Design Procedure Form: Extended Detention Basin (EDB) TLE Miramont Redland July 8, 2013 Basin 1 and 4 Forebay Design TJF Choose One Excess Urban Runoff Volume (EURV) Choose One A B C / D Water Quality Capture Volume (WQCV) UD-BMP for Basin 1 and 4, EDB 7/8/2013, 3:42 PM Sheet 2 of 4 Designer: Company: Date: Project: Location: 5. Forebay A) Minimum Forebay Volume VFMIN = 0.001 ac-ft (VFMIN = 1% of the WQCV) B) Actual Forebay Volume VF = ac-ft C) Forebay Depth DF = 6.0 in (DF = 12 inch maximum) D) Forebay Discharge i) Undetained 100-year Peak Discharge Q100 = 14.74 cfs ii) Forebay Discharge Design Flow QF = 0.29 cfs (QF = 0.02 * Q 100) E) Forebay Discharge Design F) Discharge Pipe Size (minimum 8-inches) Calculated DP = in G) Rectangular Notch Width Calculated WN = 4.2 in 6. Trickle Channel A) Type of Trickle Channel F) Slope of Trickle Channel S = ft / ft 7. Micropool and Outlet Structure A) Depth of Micropool (2.5-feet minimum) DM = ft B) Surface Area of Micropool (10 ft 2 minimum) A M = sq ft C) Outlet Type D) Depth of Design Volume (EURV or 1.2 WQCV) Based on the Design H = feet Concept Chosen Under 1.E. E) Volume to Drain Over Prescribed Time WQCV = ac-ft F) Drain Time TD = hours (Min TD for WQCV= 40 hours; Max T D for EURV= 72 hours) G) Recommended Maximum Outlet Area per Row, (Ao) A o = square inches H) Orifice Dimensions: i) Circular Orifice Diameter or Dorifice = inches ii) Width of 2" High Rectangular Orifice Worifice = inches I) Number of Columns nc = number J) Actual Design Outlet Area per Row (Ao) A o = square inches K) Number of Rows (nr) nr = number L) Total Outlet Area (Aot) A ot = square inches UD-BMP for Basin 1 and 4, EDB 7/8/2013, 3:42 PM Sheet 3 of 4 Designer: Company: Date: Project: Location: 8. Initial Surcharge Volume A) Depth of Initial Surcharge Volume DIS = in (Minimum recommended depth is 4 inches) B) Minimum Initial Surcharge Volume VIS = cu ft (Minimum volume of 0.3% of the WQCV) C) Initial Surcharge Provided Above Micropool Vs= cu ft 9. Trash Rack A) Type of Water Quality Orifice Used B) Water Quality Screen Open Area: At = 38.5*(e -0.095D )*Aot At = square inches C) For 2", or Smaller, Circular Opening (See Fact Sheet T-12): i) Width of Water Quality Screen and Concrete Opening (Wopening) W opening = inches ii) Height of Water Quality Screen (HTR) H TR = inches iii) Type of Screen, Describe if "Other" D) For 2" High Rectangular Opening: i) Width of Rectangular Opening (Worifice) W = inches ii) Width of Water Quality Screen Opening (Wopening) W opening = ft iii) Height of Water Quality Screen (HTR) H TR = ft iv) Type of Screen, Describe if "Other" v) Cross-bar Spacing inches vi) Minimum Bearing Bar Size Design Procedure Form: Extended Detention Basin (EDB) July 8, 2013 TLE Miramont Basin 1 and 4 Forebay Design Redland TJF Choose One Circular (up to 2" diameter) Rectangular (2" high) Choose One S.S. Well Screen with 60% Open Area* Other (Describe): Choose One Aluminum Amico-Klemp SR Series (or equal) Other (Describe): UD-BMP for Basin 1 and 4, EDB 7/8/2013, 3:42 PM Sheet 4 of 4 Designer: Company: Date: Project: Location: 10. Overflow Embankment A) Describe embankment protection for 100-year and greater overtopping: B) Slope of Overflow Embankment ZE = ft / ft (Horizontal distance per unit vertical, 4:1 or flatter preferred) 11. Vegetation 12. Access A) Describe Sediment Removal Procedures Notes: TLE Miramont Basin 1 and 4 Forebay Design Design Procedure Form: Extended Detention Basin (EDB) July 8, 2013 Redland TJF Choose One Irrigated Not Irrigated Final Drainage Report for The Learning Experience at Miramont Office Park 16 Appendix D - Reference Documents and Excerpts !( !( !( !( !( E HARMONY RD S LEMAY AVE S TIMBERLINE RD ZIEGLER RD STRAUSS CABIN RD KECHTER RD Preston •Pond Retrofit Jr. Existing High Pond to accommodate Water Quality Volume Willow •Pond Retrofit Springs Existing Pond to accommodate Water Quality Volume Harmony •Pond Retrofit Existing Crossing Pond to accommodate Water Quality Volume Miramont •Pond Retrofit Existing Pond to accommodate Water Quality Volume McClellands Creek Oak •Pond Retrofit Ridge Existing Pond to accommodate Water Quality Volume Proposed andRestoration Habitat Stream Improvements H F D C B Selected Plan McClellands - Water Quality Creek Basin Improvements . 1 inch = 0.125 miles McClellands Creek Basin Proposed BMP Basin Type Flood Control Only Water Quality Only Flood Control and Water Quality Proposed ProposedImprovements Water Quality Selected Alternatives Plan Natural Area Proposed Stream Restoration and Habitat Improvements 0 660 1,320 1,980 2,640 Feet Proposed Final Drainage Report for The Learning Experience at Miramont Office Park 17 Appendix E - Drainage Plan M) Depth of WQCV (HWQCV) H WQCV = feet (Estimate using actual stage-area-volume relationship and VWQCV) N) Ensure Minimum 40 Hour Drain Time for WQCV TD WQCV = hours TLE Miramont July 8, 2013 Redland Design Procedure Form: Extended Detention Basin (EDB) (flow too small for berm w/ pipe) Basin 1 and 4 Forebay Design TJF Choose One Wall with Rect. Notch Berm With Pipe Choose One Orifice Plate Other (Describe): Choose One Concrete Soft Bottom Wall with V-Notch Weir #N/A #N/A #N/A #N/A #N/A STAGE-DISCHARGE SIZING OF THE SPILLWAY TLE at Miramont Existing Spillway Capacity #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Routing 2: Water flows through WQCV plate and #1 vertical opening and #1 horizontal opening into #2 vertical opening (#2 horizontal opening is not used). STAGE-DISCHARGE SIZING OF THE WEIRS AND ORIFICES (INLET CONTROL) TLE at Miramont #12026 Current Routing Order is #2 W.S. EL. WQ W.S. EL. Minor W.S. EL. Major WQ H1 H2 V1 V2 Routing Order #1 (Standard) V1 W.S. EL. WQ W.S. EL. Design Storm WQ H1 Routing Order #3 (Single Stage) Routing Order #4 V2 V1 H1 WQ W.S. EL. Major W.S. EL. Minor W.S. EL. WQ W.S. EL. Emergency Spillway Emergency Overflow into Pipe- H2 V2 H1 WQ W.S. EL. Major W.S. EL. Minor W.S. EL. WQ V1 Routing Order #2 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Central Elevations of Rows of Holes in feet Collection Capacity for Each Row of Holes in cfs STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET TLE at Miramont #12026 #N/A #N/A #N/A #N/A STAGE-STORAGE SIZING FOR DETENTION BASINS TLE AT Miramont Check Basin Shape 175 0.65 0.388 0.54 0.39 0.095 0.294 175 1.33 0.921 0.54 0.98 0.236 0.685 180 0.64 0.391 0.54 0.39 0.097 0.294 180 1.30 0.928 0.54 0.98 0.243 0.685 185 0.62 0.394 0.54 0.39 0.100 0.294 185 1.27 0.934 0.54 0.98 0.249 0.686 190 0.61 0.396 0.53 0.39 0.102 0.294 190 1.25 0.941 0.53 0.97 0.255 0.686 195 0.60 0.399 0.53 0.39 0.105 0.294 195 1.22 0.947 0.53 0.97 0.261 0.685 200 0.59 0.401 0.53 0.39 0.107 0.294 200 1.20 0.953 0.53 0.97 0.268 0.685 205 0.58 0.404 0.53 0.39 0.110 0.294 205 1.18 0.959 0.53 0.97 0.274 0.685 210 0.57 0.406 0.53 0.39 0.112 0.294 210 1.16 0.964 0.53 0.97 0.280 0.684 215 0.56 0.409 0.53 0.39 0.115 0.294 215 1.14 0.970 0.53 0.97 0.287 0.683 220 0.55 0.411 0.53 0.39 0.117 0.294 220 1.12 0.975 0.53 0.97 0.293 0.683 225 0.54 0.413 0.53 0.39 0.120 0.294 225 1.10 0.981 0.53 0.97 0.299 0.682 230 0.53 0.416 0.53 0.39 0.122 0.293 230 1.08 0.986 0.53 0.96 0.305 0.681 235 0.52 0.418 0.53 0.39 0.125 0.293 235 1.06 0.991 0.53 0.96 0.312 0.680 240 0.51 0.420 0.53 0.38 0.127 0.293 240 1.05 0.996 0.53 0.96 0.318 0.678 245 0.50 0.422 0.53 0.38 0.130 0.292 245 1.03 1.001 0.53 0.96 0.324 0.677 250 0.50 0.424 0.53 0.38 0.132 0.292 250 1.01 1.006 0.53 0.96 0.331 0.676 255 0.49 0.426 0.53 0.38 0.135 0.291 255 1.00 1.011 0.53 0.96 0.337 0.674 260 0.48 0.428 0.53 0.38 0.137 0.291 260 0.98 1.016 0.53 0.96 0.343 0.673 265 0.47 0.430 0.52 0.38 0.140 0.290 265 0.97 1.020 0.52 0.96 0.349 0.671 270 0.47 0.432 0.52 0.38 0.142 0.290 270 0.96 1.025 0.52 0.96 0.356 0.669 275 0.46 0.434 0.52 0.38 0.145 0.289 275 0.94 1.030 0.52 0.96 0.362 0.668 280 0.46 0.436 0.52 0.38 0.147 0.288 280 0.93 1.034 0.52 0.95 0.368 0.666 285 0.45 0.438 0.52 0.38 0.150 0.288 285 0.92 1.038 0.52 0.95 0.375 0.664 290 0.44 0.439 0.52 0.38 0.152 0.287 290 0.91 1.043 0.52 0.95 0.381 0.662 295 0.44 0.441 0.52 0.38 0.155 0.286 295 0.89 1.047 0.52 0.95 0.387 0.660 300 0.43 0.443 0.52 0.38 0.157 0.286 300 0.88 1.051 0.52 0.95 0.393 0.658 Mod. FAA Minor Storage Volume (cubic ft.) = 14,381 Mod. FAA Major Storage Volume (cubic ft.) = 27,036 Mod. FAA Minor Storage Volume (acre-ft.) = 0.3301 Mod. FAA Major Storage Volume (acre-ft.) = 0.6207 Determination of MINOR Detention Volume Using Modified FAA Method Determination of MAJOR Detention Volume Using Modified FAA Method DETENTION VOLUME BY THE MODIFIED FAA METHOD TLE at Miramont Basin A (For catchments less than 160 acres only. For larger catchments, use hydrograph routing method) (NOTE: for catchments larger than 90 acres, CUHP hydrograph and routing are recommended) 10/1/2013 DIRECT RUNOFF TOTAL RUNOFF STREET PIPE TRAVEL TIME 0.81 13.38 8.24 0.59 A7 A7 0.18 0.70 8.22 8.33 9.42 Sum of A2 and A7 (Inlet 1-1) A6 A6 A5 A5 0.11 0.83 5.58 0.09 9.42 A2 0.87 6.58 0.56 8.96 0.12 0.11 0.83 5.58 B2 B2 0.76 0.82 10.42 B1 B1 0.38 0.83 5.00 0.31 0.09 STORM LINE (1) Inlet 1-2 A1 A1 2.26 8.47 Sum of A1 and A4 A2 A2 0.65 A3 A3 0.21 0.52 5.00 B3 B3 0.06 0.79 A4 A4 0.13 0.31 8.45 0.04 4.04 0.17 0.71 13.38 1.61 3.35 5.39 STORM LINE (1) Inlet 1-2 A1 A1 2.26 STANDARD FORM SF-3 - DEVELOPED STORM DRAINAGE DESIGN - RATIONAL METHOD 2 YEAR EVENT 10/1/2013 DIRECT RUNOFF TOTAL RUNOFF STREET PIPE TRAVEL TIME 8.45 0.02 2.36 0.04 2.26 1.34 0.08 2.70 8.2 0.56 2.39 0.18 0.46 8.22 0.08 2.39 2.85 0.22 0.64 13.38 Sum of A2 and A7 (Inlet 1-1) A6 A6 0.11 0.73 5.58 0.22 Sum on A1 and A4 A2 A2 0.65 0.74 6.58 0.48 2.57 1.23 A5 A5 0.11 0.73 5.58 0.08 1.44 13.4 1.45 1.96 1.96 2.82 0.04 B2 B2 0.76 A3 A3 0.21 0.57 8.47 0.04 2.36 0.25 2.78 0.69 0.64 10.42 0.49 B3 B3 0.06 2.18 1.06 0.09 A2