HomeMy WebLinkAboutFORT COLLINS VETERINARY EMERGENCY & REHABILITATION HOSPITAL - FDP - FDP130038 - SUBMITTAL DOCUMENTS - ROUND 1 -October 2, 2013 Courtney Levingston City of Fort Collins Current Planning E-mail: clevingston@fcgov.com Re: Fort Collins Veterinary Emergency & Rehabilitation Hospital 808 & 816 S. Lemay Avenue, Fort Collins CO, 80524 Two-Story Addition to the existing clinic PDP130018, Round 2 Review This letter is to address the Round 2 PDP comments on the above referenced project. Below are the comments, in Italics, and our response is in bold. All comments are also reflected as revisions on the Site Plan (Sheet SDP1), Site Details (Sheet SDP2) and Exterior Elevations (Sheets A1 & A2) dated 10.2.13 along with the Civil documents provided by North Star Design, Inc., the Landscape design provided by The Frederickson Group, LLC and the Photometric provided by R.J. McNutt. Comment Summary: Department: Current Planning Contact: Courtney Levingston, 970-416-2283, clevingston@fcgov.com Topic: General Comment Number: 3 Comment Originated: 07/01/2013 07/11/2013: There is a 14 day appeal period after the hearing. You may submit for Final Plan review prior to the appeal period expiration (at your own risk). 07/01/2013: Final Plan submittals are accepted by appointment with the front desk on Wednesdays. Please call 970-224-6134 to schedule your appointment. Acknowledged. Comment Number: 4 Comment Originated: 08/28/2013 08/28/2013: Please have a note on the site plan regarding the approved modifications: "Modifications to Section 3.2.1(E)(4)(a), and Section 3.2.2(J) regarding parking lot setbacks and landscaping as well as a modification to Section 4.27(D)(2) regarding Secondary uses in the Employment Zone District was approved by the Planning and Zoning Board on August 8, 2013." This note was added to the Site Plan, sheet SDP1. Department: Engineering Development Review Contact: Andrew Gingerich, 970-221-6603, agingerich@fcgov.com Topic: Construction Drawings Comment Number: 6 Comment Originated: 06/05/2013 07/17/2013: Thank you for including the callout for the Type I Driveway, please include a detail in the back at Final. Detail 706 is included on Sheet 7 06/05/2013: Sheet 3 & 4 - The southern driveway will need to be constructed to City Standard Type I driveway and have concrete to back of Right of Way. Please provide the Driveway detail in the details. Comment Number: 7 Comment Originated: 06/05/2013 07/17/2013: The sidewalk will need to have the most recent metal culvert detail which has flares on the sidewalk. Please include this design and detail at Final. Detail 10B is included on Sheet 7 06/05/2013: Sheet 4 - The sidewalk will need to be moved to the east so that the back of the sidewalk is on the Right of Way line. Comment Number: 9 Comment Originated: 06/05/2013 07/17/2013: This revised design appears it will satisfy the no greater than 750 sq. feet requirement, However some further discussion at final will need to be had as to the swale runout after the culvert as the city standard is concrete channel to back of curb. Added concrete channel from walk to Lemay. 06/05/2013: Sheet 4 - There is greater than 750 square feet draining from the site across the Southern Driveway Access. This runoff will need to discharge from the site in a location other than the driveway. Consider modifying grades and providing a Sidewalk chase on one side of the Type I Driveway. Topic: Site Plan Comment Number: 2 Comment Originated: 06/05/2013 06/05/2013: The additional 1' of Right of Way will need to be dedicated by separate document which will be $250 to submit. Please submit the legal and exhibit for review. This document and exhibit is in progress and it will be delivered at a later date. A check for $250 is provided with this submittal. Department: Environmental Planning Contact: Lindsay Ex, 970-224-6143, lex@fcgov.com Topic: General Comment Number: 1 Comment Originated: 05/30/2013 05/30/2013: No comments. Department: Forestry Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com Topic: General Comment Number: 6 Comment Originated: 07/17/2013 07/17/2013: Show placement of the three honeylocust street trees in the middle of the parkway. They should be shown to be planted in the middle of the parkway. The proposed honeylocust street trees have been shifted to the middle of the parkway Topic: Landscape Plans Comment Number: 4 Comment Originated: 06/11/2013 06/11/2013: New sidewalk along South Lemay needs to be adjusted to be 5 feet away from the outer bark of the existing Austrian Pine as it passes by this tree. Show accurate location of the Austrian Pine on the Utility/Engineering Plans. This has been corrected. Comment Number: 5 Comment Originated: 07/17/2013 07/17/2013: The utility plan set does not show the sidewalk bending as it passes by the large Austrian Pine to retain along Lemay. The Austrian Pine needs to be shown on the utility plan set and the sidewalk bending around the Austrian Pine as shown on the landscape plan and site plan. This has been corrected. Department: Light And Power Contact: Rob Irish, 970-224-6167, rirish@fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/03/2013 06/03/2013: Existing building @ 816 is fed by a 25KVA 120/240v service at the NE corner of the building. The primary for this transformer runs along the North side of the building from Lemay Ave. This primary will be in direct conflict with the building expansion. Contact Light & Power Engineering @ 970-221-6700 early in the process to discuss options. Any relocation or modification to the existing electric facilities will be at the owners expense. Existing 25kVA transformer feeding 816 Lemay will be removed once a temporary feed has been established from the new service. Will note on drawings. Comment Number: 4 Comment Originated: 06/03/2013 06/03/2013: Field locate all existing electric facilities and show on the site plan. This will help with any conflicts there may be. All existing site utilities are shown on Civil drawings. Will note on drawings. Comment Number: 6 Comment Originated: 07/10/2013 07/10/2013: The existing electric primary to the single-phase 25kva transformer maybe in direct conflict of the building expansion. This transformer is on a radial feed with no backup. This could be problematic in keeping the building in power while building the addition. Contact Light & Power Engineering to discuss options. 970-222-6700. New 600A 3 phase service will be set at existing car wash first. Once new service is set, a new temporary feed to the existing vet building will be set and the existing 25kVA transformer and primary feeder shall be removed to allow access to expand the building north as planned. After the existing buildings have been connected, a permanent feed to the existing vet service will be established through the interior of the building. Once permanent feed has been established, the temporary feed shall be removed. Will note on drawings. Department: PFA Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org Topic: General Comment Number: 01 Comment Originated: 06/04/2013 06/04/2013: FIRE CONTAINMENT The building exceeds 5000 square feet and shall be sprinklered or fire contained. If containment is used, the containment construction shall be reviewed and approved by the Poudre Fire Authority prior to installation. See note below. Comment Number: 02 Comment Originated: 07/11/2013 07/11/2013: The comment pertaining to FIRE CONTAIMENT (No. 1 above) was originated on 12/14/12 and to date, this concern has not been addressed by the applicant. If fire separation is being proposed in lieu of sprinklering the building, fire containment needs to be detailed on the plans. Until then, this comment shall remain active. Otherwise, the building WILL require an automatic sprinkler system. You may contact me with questions. Approved. Comment was addressed with a phone conversation with Jim on Sept. 26. Jim did not receive our last comment letter that stated our previous comments; " The existing 1-hour CMU wall , located on the north property line, will remain between the existing building and the addition. Two new rated door openings will also provided. This wall will also act as our area separation that complies with the 5,000 SF maximum PFA requires for un- sprinkled buildings." Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 05/29/2013 05/29/2013: The site disturbs more than 10,000 sq-ft and in a sensitive area, therefore Erosion and Sediment Control Materials need to be submitted for FDP. The erosion control requirements are in the Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials Submitted does not meet requirements. Please submit; Erosion Control Plan, Erosion Control Report, and an Escrow / Security Calculation. If you need clarification concerning this section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Topic: General Comment Number: 3 Comment Originated: 07/18/2013 07/18/2013: Stormwater is ready for a hearing. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Construction Drawings Jeff – these comments were corrected but you did not receive the new plans. Comment Number: 2 Comment Originated: 06/04/2013 07/12/2013: The index on sheet 1 does not match the title on sheet 5. See redlines. Corrected Sheet 5 06/04/2013: The index on sheet 1 does not match the title on sheets 4 & 5. See redlines. Comment Number: 3 Comment Originated: 06/04/2013 07/12/2013: Repeat Comment: This has not been corrected. The GIS website has incorrect elevations. Please contact Technical Services for correct benchmark information. Corrected 06/04/2013: Please correct the elevation for benchmark F-136. See redlines. Comment Number: 4 Comment Originated: 06/04/2013 07/12/2013: This has been addressed on sheet 1, but suggest also adding it to sheet 2. Corrected 06/04/2013: Please add a second benchmark to sheets 1 & 2. Utility Plan Submittal Requirement I.(G) states "benchmarks". Comment Number: 5 Comment Originated: 06/04/2013 07/12/2013: Repeat Comment: None of these issues have been corrected. Corrected 06/04/2013: There are line over text issues on sheets 3, 4 & 5. See redlines. Comment Number: 6 Comment Originated: 06/04/2013 07/12/2013: Repeat Comment: This has not been corrected. Corrected 06/04/2013: Please change the 12' utility easement on sheet 4, to include "non-vehicular access". See redlines. Comment Number: 7 Comment Originated: 06/04/2013 07/12/2013: Repeat Comment: This has not been corrected. Corrected 06/04/2013: Please change the subdivision name shown on sheet 4, to Lemay LTD First Subdivision. See redlines. Topic: Site Plan Comment Number: 16 Comment Originated: 06/05/2013 07/12/2013: There are still a few line over text issues. See redlines. Acknowledged. Please refer to the Site Plan, sheet SDP1. 06/05/2013: There are many line over text issues. See redlines. Acknowledged. Please refer to the Site Plan, sheet SDP1. Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanford@fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 06/03/2013 07/15/2013: Traffic Signing and Pavement Marking Notes not revised as requested. Please revise to state "local entity Traffic Engineer" instead of "local entity engineer". Corrected 06/03/2013: Please revise the Signing and Marking Construction Notes to state the Local Entity Traffic Engineer at all instances which currently state the Local entity Engineer. This is a permanent revision to the Fort Collins S&M notes. Please revise your NOTES file to reflect the revision. Department: Water-Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com Topic: Landscape Plans Comment Number: 2 Comment Originated: 07/16/2013 07/16/2013: Show sewer service on the landscape plan and adjust trees accordingly. The sewer service is now shown on the landscape plan. There was no need to adjust the proposed trees as they are more than 10’ from the sewer service line. There is one tree that appears to be on top of the service line but this tree is an existing tree. I hope the above information is responsive to your plan review comments and will allow the finalization of the City of Fort Collins Project Development Plan review. Should you have any questions, or need additional information, please contact me at your convenience. Sincerely, BJ DeForge Hauser Architects, PC 970.669.8220 bj@hauserarchitectspc.com