HomeMy WebLinkAboutASPEN HEIGHTS STUDENT HOUSING - FDP - FDP130010 - PLANS - UTILITY PLANS (170)4.5' MIN.
5.5' MAX. 4.5' MIN.
5.5' MAX.
34
KEYMAP
NOT TO SCALE
No. Revision/Issue Date
1269 CLEVELAND AVE #4
deanne@TFGcolorado.com (970) 669-3737
PLANNERS / LANDSCAPE ARCHITECTS
SHEET
OF
PROJECT:
155-101FC
DATE: DRAWN BY:
OCG
SCALE:
By:
THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE OF THE FREDERICKSON GROUP, LLC. THE FREDERICKSON GROUP SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, BE HELD HARMLESS AND RELEASED
OF ANY DAMAGE,LIABILITY, OR COST ALLEGEDLY ARISING OUT OF UNAUTHORIZED MODIFICATION, CHANGE, OR REUSE OF THIS DOCUMENT BY OTHERS.
3715 Shallow Pond Drive
Ft. Collins, CO 80528
Phone: (970) 226-0264
larrycowen@comcast.net
16 SEPT 2013
70
ASPEN HEIGHTS, FORT COLLINS
LOVELAND,CO 80537
1"=50'
BLUE SPRUCE DRIVE
ECHO MOUNTAIN LANE
SANGRE DE CRISTO LANE
200'
GRAPHIC SCALES
50' 0' 25' 50' 100'
HORIZ: 1 INCH = 50 FEET
5' 0' 2.5' 5' 10' 20'
VERT: 1 INCH = 5 FEET
1-800-922-1987
WATER PROFILE NOTES:
1. ALL WATERLINE CONSTRUCTION SHALL
CONFORM TO THE CITY OF FORT COLLINS
WATER, WASTEWATER, AND STORMWATER
DEVELOPMENT CONSTRUCTION STANDARDS
AND DETAILS.
2. ALL WATERLINE TO BE CONSTRUCTED A
MINIMUM OF 4.5' AND A MAXIMUM OF 5.5' (5'
TYPICAL) BELOW FINISHED GRADE UNLESS
NOTED OTHERWISE.
3. ALL WATERLINE SERVICES TO BE 3/4" UNLESS
NOTED OTHERWISE.
4. PROVIDE 10' HORIZONTAL CLEARANCE
BETWEEN WATER AND SEWER MAINS.
5. ALL GATE VALVES SHALL BE INSTALLED WITH
BOXES.
6. IF WATERLINES ARE IN DEFLECTION, 10' ON
BOTH SIDES OF THE CROSSING ARE TO BE
STRAIGHT, FOLLOWED BY THE APPROPRIATE
DEFLECTION.
7. WATER SERVICES THAT CONFLICT WITH
STORM SEWER AND CANNOT MAINTAIN 4.5' OF
COVER AND 18" VERTICAL SEPARATION SHALL
BE LOWERED TO A MINIMUM 18" BELOW THE
STORM SEWER.
8. EXACT LOCATION OF EXISTING WATER MAIN
TAP LOCATIONS HAVE NOT BEEN POTHOLE
LOCATED AND ARE NOT KNOWN.
CONTRACTOR TO POTHOLE AND DETERMINE
EXACT LOCATIONS AND OBTAIN REVIEW AND
APPROVAL FROM ENGINEER PRIOR TO
CONSTRUCTION.
9. SLEEVE LOCATIONS SHOWN ARE
APPROXIMATE . VERIFY WITH EACH UTILITY
EXACT LOCATIONS AND SIZES. ALL SLEEVES
SHALL MAINTAIN 3 FEET OF COVER UNDER
PUBLIC STREETS AT ALL TIMES.
10. SEE DETAILED UTILITY SHEETS FOR
PROPOSED GAS, ELECTRIC, AND FIBER OPTIC
MAINS AND SERVICES. VERIFY ALL DRY
UTILITY LOCATIONS PRIOR TO
CONSTRUCTION
WATER PLAN/PROFILE
ECHO MOUNTAIN/10 MILE
LA GARITA/SANGRE DE CRISTO (SW)
TEN MILE RANGE
TEN MILE RANGE
LA GARITA LANE