HomeMy WebLinkAboutASPEN HEIGHTS STUDENT HOUSING - FDP - FDP130010 - PLANS - UTILITY PLANS (129)4.5' MIN.
5.5' MAX.
35
1-800-922-1987
KEYMAP
NOT TO SCALE
No. Revision/Issue Date
1269 CLEVELAND AVE #4
deanne@TFGcolorado.com (970) 669-3737
PLANNERS / LANDSCAPE ARCHITECTS
SHEET
OF
PROJECT:
155-101FC
DATE: DRAWN BY:
OCG
SCALE:
By:
THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE OF THE FREDERICKSON GROUP, LLC. THE FREDERICKSON GROUP SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, BE HELD HARMLESS AND RELEASED
OF ANY DAMAGE,LIABILITY, OR COST ALLEGEDLY ARISING OUT OF UNAUTHORIZED MODIFICATION, CHANGE, OR REUSE OF THIS DOCUMENT BY OTHERS.
3715 Shallow Pond Drive
Ft. Collins, CO 80528
Phone: (970) 226-0264
larrycowen@comcast.net
16 SEPT 2013
70
ASPEN HEIGHTS, FORT COLLINS
LOVELAND,CO 80537
1"=50'
FIREWEED LANE
FORGET-ME-NOT LANE
BLUE SPRUCE DRIVE
200'
GRAPHIC SCALES
50' 0' 25' 50' 100'
HORIZ: 1 INCH = 50 FEET
5' 0' 2.5' 5' 10' 20'
VERT: 1 INCH = 5 FEET
WATER PROFILE NOTES:
1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO
THE CITY OF FORT COLLINS WATER, WASTEWATER,
AND STORMWATER DEVELOPMENT CONSTRUCTION
STANDARDS AND DETAILS.
2. ALL WATERLINE TO BE CONSTRUCTED A MINIMUM OF
4.5' AND A MAXIMUM OF 5.5' (5' TYPICAL) BELOW
FINISHED GRADE UNLESS NOTED OTHERWISE.
3. ALL WATERLINE SERVICES TO BE 3/4" UNLESS NOTED
OTHERWISE.
4. PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN
WATER AND SEWER MAINS.
5. ALL GATE VALVES SHALL BE INSTALLED WITH BOXES.
6. IF WATERLINES ARE IN DEFLECTION, 10' ON BOTH SIDES
OF THE CROSSING ARE TO BE STRAIGHT, FOLLOWED
BY THE APPROPRIATE DEFLECTION.
7. WATER SERVICES THAT CONFLICT WITH STORM SEWER
AND CANNOT MAINTAIN 4.5' OF COVER AND 18"
VERTICAL SEPARATION SHALL BE LOWERED TO A
MINIMUM 18" BELOW THE STORM SEWER.
8. EXACT LOCATION OF EXISTING WATER MAIN TAP
LOCATIONS HAVE NOT BEEN POTHOLE LOCATED AND
ARE NOT KNOWN. CONTRACTOR TO POTHOLE AND
DETERMINE EXACT LOCATIONS AND OBTAIN REVIEW
AND APPROVAL FROM ENGINEER PRIOR TO
CONSTRUCTION.
9. SLEEVE LOCATIONS SHOWN ARE APPROXIMATE .
VERIFY WITH EACH UTILITY EXACT LOCATIONS AND
SIZES. ALL SLEEVES SHALL MAINTAIN 3 FEET OF COVER
UNDER PUBLIC STREETS AT ALL TIMES.
10. SEE DETAILED UTILITY SHEETS FOR PROPOSED GAS,
ELECTRIC, AND FIBER OPTIC MAINS AND SERVICES.
VERIFY ALL DRY UTILITY LOCATIONS PRIOR TO
CONSTRUCTION
WALLFLOWER LANE
WATER PLAN/PROFILE
FIREWEED, FORGET ME NOT,
WALLFLOWER (NW)