Loading...
HomeMy WebLinkAboutASPEN HEIGHTS STUDENT HOUSING - FDP - FDP130010 - PLANS - UTILITY PLANS (136)11+00 12+00 23+00 24+00 REDWOOD STREET 39 1-800-922-1987 KEYMAP NOT TO SCALE SANITARY SEWER PLAN & PROFILE 1"=50' No. Revision/Issue Date 1269 CLEVELAND AVE #4 deanne@TFGcolorado.com (970) 669-3737 PLANNERS / LANDSCAPE ARCHITECTS SHEET OF PROJECT: 155-101FC DATE: DRAWN BY: OCG SCALE: By: THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE OF THE FREDERICKSON GROUP, LLC. THE FREDERICKSON GROUP SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, BE HELD HARMLESS AND RELEASED OF ANY DAMAGE,LIABILITY, OR COST ALLEGEDLY ARISING OUT OF UNAUTHORIZED MODIFICATION, CHANGE, OR REUSE OF THIS DOCUMENT BY OTHERS. 3715 Shallow Pond Drive Ft. Collins, CO 80528 Phone: (970) 226-0264 larrycowen@comcast.net 16 SEPT 2013 70 ASPEN HEIGHTS, FORT COLLINS LOVELAND,CO 80537 No. Revision/Issue Date 1269 CLEVELAND AVE #4 deanne@TFGcolorado.com (970) 669-3737 PLANNERS / LANDSCAPE ARCHITECTS SHEET OF PROJECT: 155-101FC DATE: DRAWN BY: OCG SCALE: By: THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE OF THE FREDERICKSON GROUP, LLC. THE FREDERICKSON GROUP SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, BE HELD HARMLESS AND RELEASED OF ANY DAMAGE,LIABILITY, OR COST ALLEGEDLY ARISING OUT OF UNAUTHORIZED MODIFICATION, CHANGE, OR REUSE OF THIS DOCUMENT BY OTHERS. 3715 Shallow Pond Drive Ft. Collins, CO 80528 Phone: (970) 226-0264 larrycowen@comcast.net 16 SEPT 2013 70 ASPEN HEIGHTS, FORT COLLINS LOVELAND,CO 80537 200' GRAPHIC SCALES 50' 0' 25' 50' 100' HORIZ: 1 INCH = 50 FEET 5' 0' 2.5' 5' 10' 20' VERT: 1 INCH = 5 FEET BLUE SPRUCE DRIVE TEN MILE RANGE LANE (PRIVATE DRIVE) LA GARITA LANE (PRIVATE DRIVE) (NO NAME DRIVE) (PRIVATE DRIVE) MARY JANE WAY (PRIVATE DRIVE) COPPER MOUNTAIN STREET (PRIVATE DRIVE) STEAMBOAT STREET (PRIVATE DRIVE) SOL VISTA LANE (PRIVATE DRIVE) REDWOOD STREET SEWER PROFILE NOTES: 1. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE CITY OF FORT COLLINS WATER, WASTEWATER, AND STORMWATER DEVELOPMENT CONSTRUCTION STANDARDS AND DETAILS. 2. ALL SEWER SERVICES SHALL BE A MINIMUM OF 4" DIAMETER CONSTRUCTED AT A SLOPE OF 2%. 3. ALL 6" DIAMETER SEWER SERVICES SHALL BE CONSTRUCTED AT A MINIMUM SLOPE OF 1%. 4. PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN WATER AND SEWER MAINS. 5. WHEN GROUNDWATER IS ENCOUNTERED CLAY CUT OFF WALLS SHALL BE INSTALLED ON THE UPSTREAM SIDE OF ALL MANHOLES, IN THE MID-SECTION OF EACH MAIN LINE RUN AT INTERVALS NOT TO EXCEED 300-FEET, OR AS REQUIRED BY THE DISTRICT. SEE DETAIL SHEET FOR CLAY CUT OFF WALL DETAIL. NO NAME DR. & GARITA LN.