WALL FLOWER LN. SANITARY SEWER
No. Revision/Issue Date
1269 CLEVELAND AVE #4
deanne@TFGcolorado.com (970) 669-3737
PLANNERS / LANDSCAPE ARCHITECTS
SHEET
OF
PROJECT:
155-101FC
DATE: DRAWN BY:
OCG
SCALE:
By:
THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE OF THE FREDERICKSON GROUP, LLC. THE FREDERICKSON GROUP SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, BE HELD HARMLESS AND RELEASED
OF ANY DAMAGE,LIABILITY, OR COST ALLEGEDLY ARISING OUT OF UNAUTHORIZED MODIFICATION, CHANGE, OR REUSE OF THIS DOCUMENT BY OTHERS.
3715 Shallow Pond Drive
Ft. Collins, CO 80528
Phone: (970) 226-0264
larrycowen@comcast.net
16 SEPT 2013
70
ASPEN HEIGHTS, FORT COLLINS
LOVELAND,CO 80537
1"=50'
200'
GRAPHIC SCALES
50' 0' 25' 50' 100'
HORIZ: 1 INCH = 50 FEET
5' 0' 2.5' 5' 10' 20'
VERT: 1 INCH = 5 FEET
FIREWEED LANE
(PRIVATE DRIVE)
FORGET ME NOT LANE
(PRIVATE DRIVE)
WALLFLOWER LANE
(PRIVATE DRIVE)
LUPINE DRIVE
COPPER MOUNTAIN STREET
(PRIVATE DRIVE)
BLUE SPRUCE DRIVE
LUPINE DRIVE
BLUE SPRUCE DRIVE
FORGET ME NOT LANE
(PRIVATE DRIVE)
SEWER PROFILE NOTES:
1. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE
CITY OF FORT COLLINS WATER, WASTEWATER, AND STORMWATER
DEVELOPMENT CONSTRUCTION STANDARDS AND DETAILS.
2. ALL SEWER SERVICES SHALL BE A MINIMUM OF 4" DIAMETER
CONSTRUCTED AT A SLOPE OF 2%.
3. ALL 6" DIAMETER SEWER SERVICES SHALL BE CONSTRUCTED AT A
MINIMUM SLOPE OF 1%.
4. PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN WATER AND
SEWER MAINS.
5. WHEN GROUNDWATER IS ENCOUNTERED CLAY CUT OFF WALLS
SHALL BE INSTALLED ON THE UPSTREAM SIDE OF ALL MANHOLES,
IN THE MID-SECTION OF EACH MAIN LINE RUN AT INTERVALS NOT
TO EXCEED 300-FEET, OR AS REQUIRED BY THE DISTRICT. SEE
DETAIL SHEET FOR CLAY CUT OFF WALL DETAIL.
FORGET ME NOT LN. - FIREWEED DR. &
PLAN & PROFILE