HomeMy WebLinkAboutASPEN HEIGHTS STUDENT HOUSING - FDP - FDP130010 - PLANS - UTILITY PLANS (246)25
1-800-922-1987
160'
GRAPHIC SCALE
40' 0' 20' 40' 80'
1 INCH = 40 FEET
UTILITY PLAN - SE VINE ST.
MATCHLINE -- (SEE SHEET 23)
MATCHLINE -- (SEE SHEET 24)
KEYMAP
NOT TO SCALE
1"=40'
No. Revision/Issue Date
1269 CLEVELAND AVE #4
deanne@TFGcolorado.com (970) 669-3737
PLANNERS / LANDSCAPE ARCHITECTS
SHEET
OF
PROJECT:
155-101FC
DATE: DRAWN BY:
OCG
SCALE:
By:
THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE OF THE FREDERICKSON GROUP, LLC. THE FREDERICKSON GROUP SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, BE HELD HARMLESS AND RELEASED
OF ANY DAMAGE,LIABILITY, OR COST ALLEGEDLY ARISING OUT OF UNAUTHORIZED MODIFICATION, CHANGE, OR REUSE OF THIS DOCUMENT BY OTHERS.
3715 Shallow Pond Drive
Ft. Collins, CO 80528
Phone: (970) 226-0264
larrycowen@comcast.net
16 SEPT 2013
70
ASPEN HEIGHTS, FORT COLLINS
LOVELAND,CO 80537
(NEW VINE DRIVE)
UTILITY NOTES:
1. ALL SANITARY SEWER PIPE IS 8” OR 10” PVC SDR-35, UNLESS NOTED
OTHERWISE.
2. ALL SANITARY SEWER, WATER, AND STORMWATER CONSTRUCTION SHALL
CONFORM TO THE CITY OF FORT COLLINS WATER, WASTEWATER, AND
STORMWATER DEVELOPMENT CONSTRUCTION STANDARDS AND DETAILS
3. ALL REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III OR BETTER
UNLESS NOTED OTHERWISE.
4. ALL WATERLINE TO BE CONSTRUCTED A MINIMUM OF 4.5' AND A MAXIMUM OF
5.5' (5' TYPICAL) BELOW FINISHED GRADE UNLESS NOTED OTHERWISE.
5. ALL WATERLINE SERVICES TO BE 3/4" UNLESS NOTED OTHERWISE.
6. PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN WATER AND SEWER MAINS.
7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL
REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDS.
8. REFER TO GRADING, DRAINAGE, AND EROSION CONTROL PLANS FOR
FLOODPLAIN INFORMATION.
8. FIBER OPTIC SERVICE/CONDUIT LINES ARE SHOWN FOR REFERENCE. REFER
TO LOW-VOLTAGE SITE PLAN BY INFINISYS FOR SIZES AND DETAILS.
9. ELECTRIC MAINS AND SERVICE LOCATIONS ARE SHOWN FOR REFERENCE
ONLY. CONTACT CITY OF FORT COLLINS LIGHT AND POWER FOR EXACT
REQUIREMENTS.
10. GAS MAINS AND SERVICES ARE SHOWN FOR REFERENCE ONLY. CONTACT
XCEL ENERGY FOR EXACT SIZES AND LOCATIONS. PROVIDED 4" DIAMETER
WHITE SCHEDULE 40 SLEEVES AT ALL DRIVES AND AS SHOWN.
REDWOOD STREET
MATCHLINE --
SEE LEFT
MATCHLINE --
SEE RIGHT