Loading...
HomeMy WebLinkAboutMELDRUM OFFICE BUILDING - PDP - PDP130027 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLAN (3)PRESERVING PRESERVING PRESERVING REMOVING PRESERVING REMOVING, TOO SMALL FOR MITIGATION REMOVING, TOO SMALL FOR MITIGATION REMOVING REMOVING PRESERVE IF POSSIBLE PRESERVE IF POSSIBLE OFFSITE OFFSITE TREE INVENTORY & MITIGATION PLAN 4 SEE LANDSCAPE PLAN, SHEET 3, FOR MITIGATION TREE LOCATIONS TREE INVENTORY AND MITIGATION REQUIREMENTS # TYPE SIZE CONDITION REQUIRED MITIGATION TREES 1 HONEYLOCUST 25" GOOD 3.5 2 CHINKAPIN OAK 4" FAIR 1 3 HONEYLOCUST 24" GOOD 3.5 4 REDBUD 4" FAIR 0 5 REDBUD 4" GOOD 0 6 GREEN ASH 18" FAIR/GOOD 1.5 7 HACKBERRY 20" FAIR/GOOD 1.5 1. EXISTING TREES MARKED FOR PROTECTION AND PRESERVATION SHALL NOT BE REMOVED. 2. HEAVY EQUIPMENT SHOULD NOT BE ALLOWED TO COMPACT OVER THE ROOT ZONE OF EXISTING TREES. 3. AVOID CUTTING SURFACE ROOTS WHENEVER POSSIBLE. SIDEWALKS AND PAVING LEVELS SHOULD BE CONTOURED SUFFICIENTLY TO AVOID DAMAGE. 4. ROOT CUTS FROM EXCAVATION SHOULD BE DONE RAPIDLY. SMOOTH FLUSH CUTS SHOULD BE MADE. BACKFILL BEFORE THE ROOTS HAVE A CHANCE TO DRY OUT AND WATER THE TREE IMMEDIATELY. 5. PRIOR TO CONSTRUCTION, ALL PROTECTED TREES SHALL HAVE ORANGE PROTECTION BARRIER FENCING ERECTED, WHICH AS A MINIMUM ARE SUPPORTED BY 1" X 1" OR SIMILAR STURDY STOCK, FOR SHIELDING OF PROTECTED TREES, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE HALF (1 2) OF THE DRIP LINE, WHICH EVER IS GREATER. WITHIN THIS PROTECTION ZONE THERE SHALL BE NO MOVEMENT OF EQUIPMENT OR STORAGE OF EQUIPMENT, MATERIALS, DEBRIS, FILL OR CUT UNLESS APPROVED BY THE CITY FORESTER. 6. ALL EXISTING TREES SHALL BE PRUNED TO THE CITY FORESTER'S "MEDIUM PRUNE STANDARDS. 7. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 8. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE OR DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE, WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 9. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 10. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BY "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN NOTE (5) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POSTS STAKES A MAXIMUM OF FIFTY FEET APART AND TYING A RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. TREE PROTECTION NOTES TYPE COUNT REQUIRED MITIGATION TREES (P) = TREES BEING PRESERVED 5 0 (R) = TREES TO BE REMOVED 3 4 TOTAL 8 4 TREE MITIGATION SUMMARY (R) LOCATION COUNT MITIGATION TREES PROPOSED TO BE PLANTED ON-SITE 4 MITIGATION TREES PROPOSED TO BE PLANTED OFF-SITE 0 TOTAL 4 PROVIDED TREE MITIGATION (R) 1. TREES TO BE PRESERVED ARE A CRITICAL SCREEN CLOSE TO THE BUILDING FOUNDATION. A QUALIFIED CERTIFIED PRIVATE ARBORIST WILL EVALUATE AND SUPERVISE EXCAVATION IN THE ROOT ZONE AND OTHER WORK IMPACTING THE TREES DURING CONSTRUCTION. DEPENDING ON THE AMOUNT OF ACTUAL ROOT CUTTING OR BRANCH PRUNING DETERMINED BY THE CERTIFIED ARBORIST TO HAVE OCCURRED RETENTION OF A TREE MAY NOT BE ADVISED. TREE PROTECTION NOTES DEVELOPER / APPLICANT BLUE OCEAN ENTERPRISES, INC. BRANDON GREBE 416 W. OAK FORT COLLINS, CO 80521 970.498.2261 SITE ENGINEER AND SURVEYOR NORTHERN ENGINEERING NICK HAWS, PE, LEED AP 200 S. COLLEGE AVE. SUITE 100 FORT COLLINS, CO 80524 970.221.4158 ARCHITECT VFLA CHRIS ARONSON 401 W. MOUNTAIN AVE., SUITE 100 FORT COLLINS, CO 970.224.1191 401 West Mountain Avenue Suite 100 Fort Collins, CO 80521 fax 970.224.1662 phone 970.224.5828 www.ripleydesigninc.com Ŷ land planning Ŷ landscape architecture Ŷ Ŷ urban design Ŷ entitlement Ŷ FORT COLLINS, COLORADO MELDRUM OFFICE BUILDING IN ASSOCIATION WITH: PROJECT No.: R13-026 DRAWN BY: RDI REVIEWED BY: RDI SEAL: PDP ISSUED No. DESCRIPTION DATE 1 CONCEPTUAL REVIEW 07.15.13 2 PDP 08.28.13 REVISIONS No. DESCRIPTION DATE TRAFFIC DELICH ASSOCIATES MATT DELICH 2272 GLEN HAVEN DRIVE LOVELAND, CO 80538 970.669.5034 SCALE ACCORDINGLY IF REDUCED DRAWING NUMBER: LIGHTING ADONAI PROFESSIONAL SERVICES, INC. CHUCK POLSON 6931 BROADWAY DENVER, CO 80221 303.287.8091 1 4 5 6 7 2 3 (P) (R) (P) (P) (P)