Loading...
HomeMy WebLinkAboutTHE LEARNING EXPERIENCE @ MIRAMONT OFFICE PARK - PDP130023 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLAN9+87 10+00 T 6 CS 2 PC 6 CI 3 GD 4 CS 7 CI 12 HES 2 CS 1 PC 11 CAB 5 CO WETLAND SEED MIX 1 GT 1 PC 6 VO 7" OHIO BUCKEY TO BE REMOVED 7" BLUE SPRUCE TO BE REMOVED 6.5" BLUE SPRUCE TO BE REMOVED MULCH EXISTING TURF TO REMAIN (TYP) EXISTIING TREE TO REMAIN (TYP) STEEL EDGING SHEET DRAWN CHECKED APPROVED PROJECT NO. HORZ. SCALE VERT. SCALE DATE NO. NOTES LEGEND 1" = 20'-0" 0 10 20 40 Scale: L1.0 LANDSCAPE PLAN, NOTES,LEGEND THE LEARNING EXPERIENCE MIRAMONT OFFICE PARK CPC RMC MDC 12026 07.12.2013 1 1ST SUBMITTAL SHEET DRAWN CHECKED APPROVED PROJECT NO. HORZ. SCALE VERT. SCALE DATE NO. NOTES DECIDUOUS TREE PLANTING & STAKING SCALE: 1/4"=1'-0" 2 X ROOT BALL WIDTH, MIN. 1'-0" MIN. STAKE TREES ON OPPOSITE SIDES AS SHOWN, PROVIDE TWO STAKES @ 180 DEGREES FOR ALL TREES PRUNE ALL DAMAGED WOOD PRIOR TO DELIVERY TO SITE, MULTIPLE OR "V"-SHAPED LEADERS NEED APPROVAL PRIOR TO PURCHASE DARK GREEN FABRIC STRAPS WITH BRASS GROMMETS, MIN. 12" LONG DOUBLE STRAND 12 GAUGE GALV. STEEL WIRE, TWIST TAUT WHITE 3/4" PVC PIPE ALL SIDES PROVIDE 3" HIGH SAUCER IN TURF AND 6" HIGH SAUCER IN PLANTING BED WITH MULCH, SEE SPECS. REMOVE ALL CORD, TOP 1/3RD BURLAP AND TOP BASKET STEEL "T"-POSTS, MIN. 6' LONG DRIVEN MIN. 18" DEEP PLANT 2-3" ABOVE EXISTING GRADE SCARIFY SIDES OF HOLE PRIOR TO BACK FILLING. BACK FILL MIX.: 75% NATIVE SOIL EXCAVATED FROM PIT 25% ORGANIC COMPOST NOTE: IF HOLE IS TOO DEEP, ANY SOIL ADDED TO RAISE THE ROOT BALL SHOULD BE COMPACTED. UNDISTURBED SOIL. PROVIDE TREE WRAP TO SECOND BRANCH (KRAFT OR EQUAL) WITH DUCT TAPE ANCHORS @ TOP, BOTTOM AND 2' INTERVALS AFTER SEPT. 15TH TYPICAL SHRUB PLANTING SCALE: 1/2"=1'-0" 2 X ROOT BALL WIDTH, MIN. REMOVE PLANT FROM CONTAINER OR W/ B&B MATERIAL, REMOVE WIRE BASKET FROM ROOT BALL AND PEEL BACK BURLAP AFTER 2/3 BURIED IN PIT. PLANT CROWN AT 2" ABOVE FINISHED GRADE. MULCH, SEE SPECS. EASE BACK SLOPE ON UPHILL SIDE, WHERE APPLICABLE. 3" HIGH WATER RETENTION BERM EXCEPT IN DRIP IRRIGATED AREAS, REMOVE AT END OF MAINTENANCE PERIOD. SCARIFY SIDES OF HOLE PRIOR TO PLANTING. BACK FILL MIX: 75% NATIVE SOIL EXCAVATED FROM PIT 25% ORGANIC COMPOST FOOT-TAMPED COMPACTED BACK FILL UNDER ROOT BALL TO ELIMINATE SETTLING. UNDISTURBED SUBSOIL. TYPICAL PERENNIAL PLANTING DETAIL SCALE: 1/2"=1'-0" PLANT LAYOUT EITHER GRID OR TRIANGLE WITH PRIOR APPROVAL BY OWNER'S REPRESENTATIVE PLANT 1" ABOVE EXISTING GRADES BY MOUNDING SOIL UNDER MULCH MULCH, SEE SPECS. DO NOT COVER PLANT BASES, LEAVE PLANT TISSUES EXPOSED PREPARE BACKFILL FOR TOP 6" MINIMUM, SEE SPECS. UNDISTURBED SOIL EQ. EQ. STEEL EDGING SCALE: 1"=1'-0" MULCH TYPE AND DEPTH VARIES SEE PLANS AND SPECS. FINISHED GRADE FOR SOD TO BE 1/2" BELOW TOP OF EDGING. TAMPER MULCH AT EDGING SO THAT IT DOES NOT SPILL INTO TURF. NOTES: 1. 2. 1/8" X 6" STEEL EDGING COLOR: BLACK EDGING STAKES INSTALL PER MANUFACTURER'S RECOMMENDATIONS SOIL SEPARATING FABRIC SEE SPECS. SEE LANDSCAPE PLAN NOTES: Fencing Height must be at least 48" high. Attach "Tree Protection Area" Signs to Fencing every 50 feet. The Tree Protection Area shall NOT be modified or removed prior to consent of the City Forester. Materials, debris, equipment, and site amenities shall NOT be stored within the Tree Protection Area. Entrance to the Tree Protection Area is NOT permitted without consent of the owner's representative. ZONE 2 LOWER CANOPY PROTECTION. TREE PROTECTION AREA The area inside a perimeter established at the Critical Root Zone (CRZ). The (CRZ) is equal to the dripline (furthest extent of the tree canopy) or is equal to one foot radially from the tree for every one inch of trunk diameter at breast height (DBH), which is ever greater. 48" min. VARIES PER TREE SIZE EXTENDS FROM DRIPLINE TO DRIPLINE ZONE 3 TREE PROTECTION DETAIL SCALE: NTS Contact the City Forester if any pruning is needed prior to work if potential for damage exist. TRUNK PROTECTION Required if construction equipment involved within ten feet or less (permitted inside the CRZ only if equipment is operated exclusively on existing hardscape and no soil compaction takes place). ZONE 1 ROOT PROTECTION Any digging, excavating, trenching, changing of grade, or other actions that may potentially impact the rooting environment must be authorized by the City Forester prior to work commencement. Work within the CRZ must take place in accordance with the conditions established by the City Forester. 1. 2. 3. 4. 5. L1.1 LANDSCAPE DETAILS THE LEARNING EXPERIENCE MIRAMONT OFFICE PARK CPC RMC MDC 12026