HomeMy WebLinkAboutASPEN HEIGHTS STUDENT HOUSING - FDP - FDP130010 - PLANS - LANDSCAPE PLAN (3)ENV-1
SHOWN
NORTH
0 50' 100' 200' 300'
SCALE: 1"= 100'-0"
FCP-SITE-EXEDRA6.Thursday, dwg May 24, 2012 8:42:45 AM
No. Revision/Issue Date
PREPARED BY:
1619 KELMSLEY CT., WINDSOR, CO 80550
deanne@TFGcolorado.com (970) 674-3323
PLANNERS / LANDSCAPE ARCHITECTS
ASPEN HEIGTS CLIENT:
SHEET
OF
PROJECT:
155-101FC
DATE: DRAWN BY:
dlk
SCALE:
By:
THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE OF THE FREDERICKSON GROUP, LLC. THE FREDERICKSON GROUP SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, BE HELD HARMLESS AND RELEASED
OF ANY DAMAGE,LIABILITY, OR COST ALLEGEDLY ARISING OUT OF UNAUTHORIZED MODIFICATION, CHANGE, OR REUSE OF THIS DOCUMENT BY OTHERS.
3715 Shallow Pond Drive
Ft. Collins, CO 80528
Phone: (970) 226-0264
larrycowen@comcast.net
FORT COLLINS, COLORADO
1301 S. CAPITAL OF TEXAS HWY
AUSTIN, TEXAS, 78746
(512) 369-3030
BUILDING B, SUITE 201
BRECKENRIDGE GROUP FORT
COLLINS COLORADO, LLC,
A TEXAS LIMITED LIABILITY
COMPANY
. . . .
1
28 MAR 2013
EXISTING TREE LOCATIONS
SCALE: 1"=100'
A
B
C
D E
F
G
H
A
STEM SIZE (CALIPER)
1.
2.
3.
17" 16"
18"
24"
12" 16" 16"
12" 10" 20" 6" 8"
15" 18" 6" 6" 6" 6" 8"
7" 6" 10" 10" 10" 6" 6" 20" 12" 6" 15"
12" 8" 10" 7"
6" 11" 12"
20" 12" 11" 10" 10" 7" 10"
8" 11" 8" 10" 10" 12" 7" 10" 6"
FAIR
FAIR
FAIR
POOR
FAIR
POOR
FAIR
FAIR
POOR
FAIR
FAIR
FAIR
2
2
2
1
4
2
4
3
1
4
4
4
TREE SPECIES:
PC: PLAINS COTTONWOOD (Populus deltoides ccidentalis)
PL: PEACH LEAF WILLOW (Salix amygdaloides)
4.
5.
6.
7.
8.
9.
10.
11.
12.
B
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
6" 6" 6" 10" 6"
10"
8"
7" 10"
6" 7" 10" 6"
8" 10" 9"
8" 10" 10" 6"
6"
11" 10" 6"
10" 6" 7" 10" 12"
10" 8" 6" 7" 6"
6" 11"
12" 18"
POOR
POOR
FAIR
FAIR
FAIR
FAIR
POOR
POOR
FAIR
FAIR
POOR
FAIR
FAIR
2
1
2
2
2
2
2
1
3
3
2
2
3
C
1.
2.
3.
4.
6"
6" 7" 9"
6"
8" 6" 7" 8" 6" 6" 11" 7" 6" 6" 9"
GOOD
GOOD
GOOD
GOOD
2
3
2
4
D
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
12" 20" 12" 12" 11" 8"
21" 6" 6" 8"
22" 24" 18"
8"
28" 12" 12"
10" 22"
8" 12" 10"
12" 15"
6" 8" 7" 7"
6" 10" 8" 8"
16"
13"
15" 7" 7" 7" 15"
6" 8" 7" 12" 15" 7"
20" 8" 7"
GOOD
GOOD
GOOD
FAIR
GOOD
GOOD
FAIR
GOOD
FAIR
GOOD
GOOD
FAIR
GOOD
GOOD
GOOD
5
4
5
2
5
4
3
4
3
3
3
2
4
4
3
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
TREE
STAND NO.
SPECIES
CONDITION
MITIGATION
17.
18.
19.
20.
21.
22.
23.
24.
25.
11" 9" 10" 12"
6" 10"
16" 13"
11" 6" 11" 22"
15" 6" 8"
10" 7" 11" 20" 16"
6"
6"
6"
GOOD
POOR
FAIR
GOOD
GOOD
GOOD
GOOD
GOOD
GOOD
3
1
2
4
3
4
2
2
2
E
1.
2.
3.
F 1.
G
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
H
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
7"
8"
8"
GOOD
GOOD
GOOD
2
2
2
8" GOOD 2
9" 11" 7" 6"
10"
14" 18" 18"
7"
8"
10" 9" 10"
14"
11" 10"
6" 8"
15" 10" 6" 7"
7"
6" 6" 6"
10"
7" 6" 7" 7"
10"
6"
7"
24"
GOOD
FAIR
GOOD
POOR
GOOD
GOOD
FAIR
GOOD
FAIR
GOOD
GOOD
FAIR
POOR
FAIR
FAIR
POOR
POOR
GOOD
4
2
4
1
2
3
2
4
2
3
2
2
1
3
2
1
1
5
PL
PL
PL
PL
PL
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
10" 16"
12" 7"
7" 10" 10"
12" 6" 7"
9"
12"
12" 14"
10" 15" 7"
6" 6" 11" 10" 10"
12" 15"
10" 10"
7" 6"
GOOD
FAIR
FAIR
POOR
POOR
FAIR
FAIR
GOOD
POOR
FAIR
GOOD
GOOD
3
2
6
2
1
2
3
4
2
3
3
3
STEM SIZE (CALIPER)
TREE
STAND NO.
SPECIES
CONDITION
MITIGATION
D
TOTAL TREE MITIGATION:
TOTAL COTTONWOOD SPECIES:
TOTAL PEACH LEAF WILLOW:
79
8
237
EXISTING TREE INVENTORY
NOTES
1. TREE MITIGATION PLAN IS SUBJECT TO SECTION 3.2.1(F) " TREE PROTECTION AND
REPLACEMENT" IN THE FORT COLLINS MUNICIPAL CODE.
2. TREE STANDS WERE FIELD IDENTIFIED AND INVENTORIED ON JANUARY 13, 2012
UNDER THE DIRECTION OF TIM BUCHANANN, FORESTER, FOR THE CITY OF FORT
COLLINS. TIM BUCHANANN RATED THE CONDITION OF EACH TREE AS PROVIDED IN THE
TABLE. IN SOME CASES MULTI-STEM TREES AND TREE GROUPINGS WERE CONSIDERED
TOGETHER.
3. MR. BUCHANANN PROVIDED A MITIGATION NUMBER FOR EACH TREE OR TREE
GROUPING. THE MITIGATION NUMBER REFERS TO THE NUMBER OF REPLACEMENT
TREES THAT WILL BE REQUIRED TO MITIGATE TREE LOSS AS A RESULT OF
CONSTRUCTION.
4. NUISANCE TREES, SUCH AS SIBERIAN ELM, FEMALE BOX-ELDER AND RUSSIAN OLIVE
WERE NOT INVENTORIED FOR THIS PLAN.
5. REPLACEMENT TREES WILL BE PLACED ON THE PREMISES AND ARE SHOWN ON THE
LANDSCAPE PLAN FOR THE PROJECT. IN SOME CASES NEW STREET TREES WILL BE
INSTALLED THAT ARE LARGER THAN THE MINIMUM REQUIRED TO MEET MITIGATION
QUANTITIES.
6. TREE STANDS ARE INDICATED ON THE SITE PLAN IN BOLD, "CLOUDS" WITH A LETTER
DESIGNATION. TREES WERE IDENTIFIED AND MEASURED IN THE ORDER AS SHOWN ON
THE MAP AND NUMBERED IN THE ABOVE TABLE. ONLY TREES THAT EXCEED 6" IN
CALIPER AS MEASURED APPROXIMATELY 5' ABOVE THE GROUND.
7. THE TREES SHOWN WITHIN THE CITY OF FORT COLLINS STORMWATER DETENTION
POND AREA WERE IDENTIFIED, BUT WILL BE PRESERVED DURING CONSTRUCTION. ALL
OTHER TREE STANDS WILL BE REMOVED AS A RESULT OF NEW CONSTRUCTION FOR THE
ASPEN HEIGHTS DEVELOPMENT AND OFF SITE ROADWAY CONSTRUCTION.
8. REPLACEMENT TREES SHALL MEET THE FOLLOWING MINIMUM SIZE REQUIREMENTS:
CANOPY SHADE TREES: 3.0" CALIPER BALLED AND BURLAP OR EQUIVALENT
ORNAMENTAL TREES: 2.5" CALIPER BALLED AND BURLAP OR EQUIVALENT
EVERGREEN TREES: 8' HEIGHT BALLED AND BURLAP OR EQUIVALENT
9. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS
NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED ON THE PUBLIC RIGHT-OF-WAY. THIS
INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS
PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS
PERMIT MAY RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF
OCCUPANCY.
10. IF ANY TREES IN GOVE D, G AND H ARE REMOVED AT A FUTURE DATE THEN THE CITY FORESTER
WILL DETERMINE IF MITIGATION NEEDS TO BE REVALUATED. CITY FORESTER MUST APPROVE ANY
TREE REMOVAL IN THESE GROVES.
CONIFER STREET
TREE MITIGATION PLAN
FUTURE OFF-SITE PHASE
IMPROVEMENTS AND LANDSCAPE
SHOW FOR REFERENCE
FUTURE OFF-SITE PHASE
IMPROVEMENTS AND LANDSCAPE
SHOW FOR REFERENCE
TOTAL TREES RETAINED:
TOTAL TREES REMOVED:
134
111
1. TREE PROTECTION SPECIFICATIONS. THE FOLLOWING TREE PROTECTION SPECIFICATIONS
SHOULD BE FOLLOWED TO THE MAXIMUM EXTENT FEASIBLE FOR ALL PROJECTS WITH
PROTECTED EXISTING TREES.
2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL
OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED
AND APPROVED THE DISTURBANCE.
3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS
FORESTRY STANDARDS.
4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL
PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM
OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET
)5207+(7581.2521(+$/) ò
2)7+('5,3/,1(:+,&+(9(5,6*5($7(57+(5(6+$//
BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE
FENCED TREE PROTECTION ZONE.
5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE
CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE
MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY
OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY
PROTECTED TREE OR GROUP OF TREES.
6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY
PROTECTED TREE.
7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM
CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS
MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH
TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING
METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE
FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED.
8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE
REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING
UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF
TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE
TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED
IN THE CHART BELOW.THES TRIANGLE. STREET TREES MUST BE LIMBED UP TO 6' ABOVE TOP
OF CURB.
TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET)
BORING DISTANCE TABLE
0-2 1
3-4 2
5-9 5
10-14 10
15-19 12
OVER 19 15
TREE PROTECTION NOTES
"NEW VINE" ALIGNMENT
LUPINE DRIVE
REDWOOD STREET
BLUE SPRUCE DRIVE
LUPINE DRIVE