HomeMy WebLinkAboutLDS TEMPLE (OF FORT COLLINS) - FDP - FDP130029 - SUBMITTAL DOCUMENTS - ROUND 1 - TRAFFIC STUDY (3)2. ALL EXISTING UTILITY LOCATIONS ARE APPROXIMATE. THE RESPONSIBLE PARTY SHALL FIELD VERIFY THE
EXACT LOCATION OF ALL UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR
ANY DAMAGES WHICH MAY OCCUR BY THE RESPONSIBLE PARTY'S FAILURE TO EXACTLY LOCATE AND PRESERVE
1. CONDUIT, POLE, AND PULL BOXES LOCATIONS ARE APPROXIMATE. EXACT LOCATIONS SHALL BE MARKED BY
THE RESPONSIBLE PARTY AND APPROVED IN THE FIELD BY THE CITY.
ANY AND ALL UNDERGROUND UTILITIES.
3. ALL WORK SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION ( AND CURRENT REVISIONS) (COLORADO DEPARTMENT OF TRANSPORTATION, 2011), THE M&S
STANDARDS (COLORADO DEPARTMENT OF TRANSPORTATION, 2012), LARIMER COUNTY UNRBAN AREA STREET
STANDARDS (2007), AND THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. THE RESPONSIBLE PARTY
SHALL CONTACT THE TRAFFIC ENGINEER A MINIMUM OF 48 HOURS AND A MAXIMUM OF 96 HOURS PRIOR TO
STARTING TRAFFIC SIGNAL CONSTRUCTION.
4. ALL SIGNAL POLES, MAST ARMS, LUMINAIRE ARMS AND EXTENSIONS SHALL BE POWDER COATING OVER
GALVANIZING. STANDARD RETARDO BROWN OR FOREST GREEN COLOR SHA BE USED.
5. STREET LIGHT LUMINAIRE EXTENSIONS (GALVANIZED AND PAINTED) SHALL BE ORDERED ON ALL POLES. A
30 FOOT LUMINAIRE MOUNTING HEIGHT AND A 15 FOOT LUMINAIRE ARM (GALVANIZED AND PAINTED) SHALL BE
USED TO MOUNT A 250 WATT HPS STREETLIGHT FIXTURE. STREETLIGHT FIXTURES ARE TO BE PURCHASED FROM
THE CITY OF FORT COLLINS WAREHOUSE.
6. ASC3 CONTROLLER AND CABINET MODEL 333SD WITH AN 8" BASE ADAPTER, WIRED FOR A FULL 8 PHASE
WITH OVERLAPS OPERATION WITH THE LATEST VERSION OF CITY APPROVED FIRMWARE IS REQUIRED.
7. CITY STANDARD FIBER/ETHERNET SWITCH AND COMPLETE WIRING IS REQUIRED.
8. OPTICOM FIRE PREEMPTION SYSTEM COMPLETE WITH DETECTORS, WIRING, AND CARD IN THE CABINET (GTT
SYSTEM) IS REQUIRED.
9. TRAFFIC SIGNAL POLES SHALL MEET CDOT S-614-40A SPECIFICATIONS AND MANUFACTURER MUST BE
PRE-APPROVED BY THE CDOT BRIDGE DIVISION.
10. SIGNALS SHALL BE YELLOW, ALUMINUM SIGNAL HEADS WITH 4" BLACK BACK PLATES (FOR OVERHEAD
SIGNALS). SIGNALS SHALL BE MOUNTED USING SKYBRACKETS OVER THE CENTER OF EACH LANE.
11. SIGNALS, STRIPING, AND SIGNING TO BE PROVIDED BY CITY OF FORT COLLINS TRAFFIC.
12. BORING TO BE PROVIDED BY CONTRACTOR.
SUMMARY OF APPROXIMATE QUANTITIES
ITEM
NUMBER
PLANNED
QUANTITY
210-00815
ITEM DESCRIPTION UNIT
202-00828
613-00200
613-00206
613-00300
613-00306
613-07026
613-10000
613-70100
614-70336
614-72855
RESET SIGN PANEL EACH
REMOVAL OF EXISTING SIGNAL
2 INCH ELECTRICAL CONDUIT
2 INCH ELECTRICAL CONDUIT (BORED)
3 INCH ELECTRICAL CONDUIT
LS
LF 70
LF 490
LF 120
LF 980
EACH 3
LS 1
EA 4
EA 4
TRAFFIC SIGNAL LEGEND
PAVEMENT MARKING SYMBOLS
LUMINAIRE (15' L. ARM, 250 W. SODIUM FIXTURE)
12"-12"-12" SIGNAL HEAD WITH BACK PLATE
12"-12"-12" SIDE-OF-POLE SIGNAL HEAD
OPTICOM DETECTOR
SIGNAL WIRE CONDUIT (C)
SIGNAL WIRE PULL BOX
16" PEDESTRIAN SIGNAL HEAD
SIGNAL POLE WITH MAST ARM
CONTROL CABINET
PEDESTRIAN PUSHBUTTON
PHASE 1
PHASE 5 PHASE 6
PHASE 2 PHASE 3
PHASE 7 PHASE 8
PHASE 4
A
B
SIGNAL POLE LOCATIONS
1
14 20
8
R
SY
FY
G
4
16 22
10 2 3
15
21
9
5
19 23
11 6 7 12
13 18 19
24 25
FOR SUBMITTAL
4
2
B
45' MAST ARM
7
6
1 3 5
INSTALL TWO
NEW PULL BOX
10
21
14 11
12
C
9
B
30' MAST ARM
ONE-2"
TWO-3"
25
24
TRAFFIC SIGNAL LEGEND
CCTV CAMERA
PHASE 1
PHASE 5 PHASE 6
PHASE 2 PHASE 3
PHASE 7 PHASE 8
PHASE 4
A
B
DELICH
SIGNAL POLE LOCATIONS
1
14 20
8 4
16 22
10 2 3
15
21
9
5
19 23
11 6 7 12
13 18 19
24 25
FOR SUBMITTAL
NOT FOR CONSTRUCTION
4
2
B
7
6
1 3 5
INSTALL TWO
NEW PULL BOX
10
21
14 11
12
C
9
B
ONE-2"
TWO-3"
25
24
23
22
20
19
18
17
16
13
8
15
23
22
20
19
18
17
16
13
8
15
EA 4
EA 1
3 INCH ELECTRICAL CONDUIT (BORED)
PULL BOX (MEDIUM)
LUMINAIRE HIGH PRESSURE SODIUM (100 WATT)
SIGN PANEL (CLASS I)
TRAFFIC SIGNAL FACE (12-12-12) WITH BACKPLATE
TRAFFIC SIGNAL CONTROLLER CABINET (333SD TYPE)
EA 2
EA 2
EA 1
EA
EA 2
614-72864
614-72886
614-86238
FIRE PREEMPTION UNIT (OPTICOM)
INTERSECTION DETECTION SYSTEM (CAMERA)
TRAFFIC SIGNAL CONTROLLER (ASC3 TYPE)
TRAFFIC SIGNAL-LIGHT POLE STEEL (30 FOOT MAST ARM)
TRAFFIC SIGNAL-LIGHT POLE STEEL (35 FOOT MAST ARM)
TRAFFIC SIGNAL-LIGHT POLE STEEL (45 FOOT MAST ARM)
614-81145
614-81150
614-81155
614-70150
614-72860
614-72855
EA 1
EA 8
EA 8
PEDESTRIAN SIGNAL HEAD (16 INCHES) (COUNTDOWN)
PEDESTRIAN PUSH BUTTON
ELECTRIC METER
1
1
4
614-70336 TRAFFIC SIGNAL FACE (12-12-12-12) WITH BACKPLATE EA 4
614-70336 TRAFFIC SIGNAL FACE (12-12-12) EA 4
614-70336 TRAFFIC SIGNAL FACE (12-12-12-12) EA 4
503-00036 DRILLED CAISSON (36 INCH) LF 57
EA 1
614-85312 TRAFFIC SIGNAL FOUNDATION EA 1
INTERSECTION DETECTION SYSTEM (CAMERA)
CCTV CAMERA (PTZ)
LS 1
EA 1
DELICH
ASSOCIATES
613-07026 PULL BOX (LARGE) EACH 1