HomeMy WebLinkAboutASPEN HEIGHTS STUDENT HOUSING - FDP - FDP130010 - PLANS - UTILITY PLANS (182)4.5' MIN.
5.5' MAX.
BLUE SPRUCE DRIVE
BLUE SPRUCE DRIVE
ECHO MOUNTAIN LANE
(PRIVATE DRIVE)
SANGRE DE CRISTO LANE
(PRIVATE DRIVE)
LA GARITA LANE
(PRIVATE DRIVE)
TEN-MILE RANGE LANE
(PRIVATE DRIVE)
(PRIVATE DRIVE)
TEN-MILE RANGE
LANE
11+00
12+00
13+00
14+00
15+00
4.5' MIN.
5.5' MAX.
33
KEYMAP
NOT TO SCALE
WATER PLAN/PROFILE
No. Revision/Issue Date
7711 WINDSONG DR, WINDSOR, CO 80550
deanne@TFGcolorado.com (970) 278-0240
PLANNERS / LANDSCAPE ARCHITECTS
SHEET
OF
PROJECT:
155-101FC
DATE: DRAWN BY:
OCG
SCALE:
By:
THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE OF THE FREDERICKSON GROUP, LLC. THE FREDERICKSON GROUP SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, BE HELD HARMLESS AND RELEASED
OF ANY DAMAGE,LIABILITY, OR COST ALLEGEDLY ARISING OUT OF UNAUTHORIZED MODIFICATION, CHANGE, OR REUSE OF THIS DOCUMENT BY OTHERS.
3715 Shallow Pond Drive
Ft. Collins, CO 80528
Phone: (970) 226-0264
larrycowen@comcast.net
3 JULY 2013
69
ASPEN HEIGHTS, FORT COLLINS
1"=50'
BLUE SPRUCE DRIVE
ECHO MOUNTAIN LANE
SANGRE DE CRISTO LANE
LA GARITA LANE
TEN-MILE RANGE LANE
200'
GRAPHIC SCALES
50' 0' 25' 50' 100'
HORIZ: 1 INCH = 50 FEET
5' 0' 2.5' 5' 10' 20'
VERT: 1 INCH = 5 FEET
WATER PROFILE NOTES:
1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE
CITY OF FORT COLLINS WATER, WASTEWATER, AND
STORMWATER DEVELOPMENT CONSTRUCTION STANDARDS
AND DETAILS.
2. ALL WATERLINE TO BE CONSTRUCTED A MINIMUM OF 4.5' AND
A MAXIMUM OF 5.5' (5' TYPICAL) BELOW FINISHED GRADE
UNLESS NOTED OTHERWISE.
3. ALL WATERLINE SERVICES TO BE 3/4" UNLESS NOTED
OTHERWISE.
4. PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN WATER AND
SEWER MAINS.
5. ALL GATE VALVES SHALL BE INSTALLED WITH BOXES.
6. IF WATERLINES ARE IN DEFLECTION, 10' ON BOTH SIDES OF
THE CROSSING ARE TO BE STRAIGHT, FOLLOWED BY THE
APPROPRIATE DEFLECTION.
7. WATER SERVICES THAT CONFLICT WITH STORM SEWER AND
CANNOT MAINTAIN 4.5' OF COVER AND 18" VERTICAL
SEPARATION SHALL BE LOWERED TO A MINIMUM 18" BELOW
THE STORM SEWER AND 2" POLY-ENCASED.
8. EXACT LOCATION OF EXISTING WATER MAIN TAP LOCATIONS
HAVE NOT BEEN POTHOLE LOCATED AND ARE NOT KNOWN.
CONTRACTOR TO POTHOLE AND DETERMINE EXACT
LOCATIONS AND OBTAIN REVIEW AND APPROVAL FROM
ENGINEER PRIOR TO CONSTRUCTION.
1-800-922-1987