HomeMy WebLinkAboutASPEN HEIGHTS STUDENT HOUSING - FDP - FDP130010 - PLANS - UTILITY PLANS (189)23+00 22+00 21+00
REDWOOD STR
39
1-800-922-1987
KEYMAP
NOT TO SCALE
SANITARY SEWER PLAN
MATCHLINE -- 7+00
MATCHLINE -- 7+00
No. Revision/Issue Date
7711 WINDSONG DR, WINDSOR, CO 80550
deanne@TFGcolorado.com (970) 278-0240
PLANNERS / LANDSCAPE ARCHITECTS
SHEET
OF
PROJECT:
155-101FC
DATE: DRAWN BY:
OCG
SCALE:
By:
THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE OF THE FREDERICKSON GROUP, LLC. THE FREDERICKSON GROUP SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, BE HELD HARMLESS AND RELEASED
OF ANY DAMAGE,LIABILITY, OR COST ALLEGEDLY ARISING OUT OF UNAUTHORIZED MODIFICATION, CHANGE, OR REUSE OF THIS DOCUMENT BY OTHERS.
3715 Shallow Pond Drive
Ft. Collins, CO 80528
Phone: (970) 226-0264
larrycowen@comcast.net
3 JULY 2013
69
ASPEN HEIGHTS, FORT COLLINS
1"=50'
200'
GRAPHIC SCALES
50' 0' 25' 50' 100'
HORIZ: 1 INCH = 50 FEET
5' 0' 2.5' 5' 10' 20'
VERT: 1 INCH = 5 FEET
ASPEN HEIGHTS WAY
(PRIVATE DRIVE)
MARY JANE WAY
(PRIVATE DRIVE)
MARY JANE WAY
(PRIVATE DRIVE)
LUPINE DRIVE
MARY JANE WAY
(PRIVATE DRIVE)
STEAMBOAT STREET
(PRIVATE DRIVE)
SEWER PROFILE NOTES:
1. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE
CITY OF FORT COLLINS WATER, WASTEWATER, AND STORMWATER
DEVELOPMENT CONSTRUCTION STANDARDS AND DETAILS.
2. ALL SEWER SERVICES SHALL BE A MINIMUM OF 4" DIAMETER
CONSTRUCTED AT A SLOPE OF 2%.
3. ALL 6" DIAMETER SEWER SERVICES SHALL BE CONSTRUCTED AT A
MINIMUM SLOPE OF 1%.
4. PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN WATER AND
SEWER MAINS.