HomeMy WebLinkAboutPROSPECT STATION - FDP - FDP130027 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONSUP
UP
DN
DN
DN
DN
DN
Option B
Live/Work
A101
Retail
Suite 101
56x48
Compact Parking Spaces
10 Spaces
Standard Parking Spaces
25 Spaces
Covered Handicap Parking
2 Spaces
Offsite Standard Parking Spaces
11 Spaces
Accessible
56x60
Accessible
56x60
Fire
Riser
Room
Electrical
Trash & Recycle Room
One way traffic
Exit Only
One One
Entrance Only
Mailboxes
Partial height wall.
Elevator Elec.
Ramp DN
Existing Railroad Tracks
Existing Bike/Pedestrian Path
1
2
1
4 2 4 2 1 4
3
5
5
Existing Bike/Pedestrian Path
6 6
6
F1
F1
F1
F1
F1
Live/Work
A102
Elevator
7
8
DN UP
DN
UP
Unit Type Number of Units Bedrooms Secure covered
bike storage
1st Floor
1 Bedroom: 1 Unit 1 Bedroom -
2 Bedroom: 1 Unit 2 Bedrooms -
3 Bedroom: - - -
2nd Floor
Studio: 6 Units 6 Bedrooms 6 spaces
1 Bedroom: 2 Unit 2 Bedroom 2 spaces
2 Bedroom: 6 Units 12 Bedrooms 12 spaces
3 Bedroom: 1 Units 3 Bedrooms 3 spaces
3rd Floor
Studio: 6 Units 6 Bedrooms 6 spaces
1 Bedroom: 2 Unit 2 Bedroom 2 spaces
2 Bedroom: 6 Units 12 Bedrooms 12 spaces
3 Bedroom: 1 Units 3 Bedrooms 3 spaces
Total Counts
Studio: 12 Units 12 Bedrooms 12 spaces
1 Bedroom: 5 Units 5 Bedroom 5 spaces
2 Bedroom: 13 Units 26 Bedrooms 26 spaces
3 Bedroom: 2 Units 6 Bedrooms 6 spaces
32 Units 49 Bedrooms 49 Spaces
Elev.
Unit 201
2 Bedroom
Unit 203
2 Bedroom
Unit 205
3 Bedroom
Unit 202
1 Bedroom
Unit 204
2 Bedroom
Unit 208
2 Bedroom
Type 'A'
Unit 209
Studio
Unit 210
Studio
L2 - East Hallway
17
L2 - North Hallway
18
10
F3 F3 F3
F3
F3 F3
F4
F4
F4
F4 F4 F4
F4 2nd Floor
3rd & 4th Floors
Unit 206
2 Bedroom
Unit 207
226 Remington St.
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4arch.com
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
Dohn Construction General Contractor
Prospect Station, LLC Owner
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
Larsen Structural Design Structural Engineer
AE Associates Mechanical Engineer
APS Electrical Engineer
ARCHITECTS
r4arch.com
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
19 Old Town Square, Suite 238
Fort Collins, CO 80524
(970) 568-3355
Contact: Blake Larsen
Email: blake@larsensd.com
5587 West 19th Street
Greeley, CO 80634
(970) 330-5587
Contact: Alicia Thorpe
Email: alicia.thorpe@aeassociates.net
6931 Broadway
Denver, CO 80221
(303) 287-8091
Contact: Chuck Polson
Email: chuck@apsinc.biz
TB Group Landscape Architect
444 Mountain Ave.
Berthoud, CO 80513
(970) 532-5891
Contact: Cathy Mathis
Email: cathy@tbgroup.us
Interwest Consultants Civil Engineer
1218 Ash Street
Windsor, CO 80550
(970) 674-3300
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Prospect
Station
1 Final Plan Submittal 7/3/2013
Final Plan Submittal
SA
Level 1 - Ground
Floor
0' - 0"
Roof
43' - 1 1/8"
Level 2
14' - 0"
Level 3
24' - 10 7/8"
Plate Height
34' - 0"
12 11 10 9 8 7 6 5 4 3 2 1
46' - 4" Roof Peak
W1
Field
W1
Accent
5
W1
Accent
W3
W3
W2
Field
- A4 -
3
R2
R1
W1
Field
2
1 1 1
4 4 4
1
W1
Field
W1
Accent
W3
W2
Field
R1
12
4.5
12
3
R1
W2
Accent
R1
W2
Accent
R1
W2
Accent
R2 R2
W3 W3
11
W4
W1
Level 1 - Ground
Floor
0' - 0"
Roof
43' - 1 1/8"
Level 2
14' - 0"
Level 3
24' - 10 7/8"
Plate Height
34' - 0"
G F E D C B A
12
W2
Field
W1
Accent
W4
W3
W2
Accent
R2
R1
W1
Field
11
W1
Accent
W1
Field
W3
12 12
Primary Entrance
Multi-Family
Primary Entrance
Retail
5
W2
Field
W3
W3
11
13 13 13
R2
W2
Accent
5
Level 1 - Ground
Floor
0' - 0"
Roof
43' - 1 1/8"
Level 2
14' - 0"
Level 3
24' - 10 7/8"
Plate Height
34' - 0"
A B C D E F G
W1
SHADOW ANALYSIS SUMMARY:
r4 Architects has developed a shadow analysis based on the available information
for assumed locations and construction of adjacent structures and the observed
grades. Winter shadow conditions are based on December 21st at incremental
times, 9am, 12 noon, and 3pm.
Based on our analysis, the proposed project does NOT have an adverse affect on
adjacent public and private property as defined in the LUC. Our shadow impact
occurs each day during limited winter months on west Prospect road to the North.
Retail buildings on the north side of Prospect are the only occupied structure within
our cast shadows and are minimally impacted during short periods of time during
winter months. Our proposed project has negligent impact during portions of 3
winter months and at limited hours in early morning and late afternoon. Storefront
windows on the ground floor are intermittently in shadow beginning at 9am and
progressing across the builing as the sun changes position. We will not have
impact and will have adequate solar gain in the morning and early afternoon in these
months. The proposed project has been sited to the southern property line and
provides proper setbacks along Prospect road.
General Note:
Neighboring structures shown in the background have been modeled using the best
information available to us at the time. r4 Architects has used aerial photographs to
determine adjacencies of the occupied buildings. In addition, we have replicated the
building massing and fenestration from photographs, site observation and traditional
construction practices for height and roof slope.
DESIGN CONSIDERATIONS TO MINIMIZE VISUAL AND SHADOW IMPACTS ON
NEIGHBORING PROPERTIES
Design considerations to minimize our solar and visual impact on neighboring
properties include the following:
• Incorporating substantial building setbacks on the North property line to
maximize pedestrian interaction with the site.
• A public plaza has been designed along the north and east frontages to
provide a pedestrian zone between sidewalks and the existing bike path.
• Oportunities for public art have been identified along the north frontage.
• Unit design to incorporate the use of HVAC units to be located on the
rooftop within a mechanical well surrounded by a mansard roof to
completely screen all mechanical equipment.
• Changes in massing and material are incorporated on all fasades for
Architectural and visual intrest.
• Contextural roof forms using flat and sloped roofs with both metal and
asphalt roofing styles.
• Use of pedestrian scale canopies, entry canopies and intricate deck railings
to provide visibility out and intrest to our project.
PROJECT SUMMARY:
r4 Architects has developed a visual analysis that identifies the extent to which
existing views may be blocked. Our project is infill on an site with an existing small
coffee shop along the new Mason Street corridor. Our project is placed five feet off
the south property boundary to allow southern windows and provide a pedestrian
plaza along Prospect Road. The project will have a defined plaza and patio that front
both Prospect Road and the Mason Street corridor. This activity node contains a
provisions for a local bus stop, direct access to the MAX, adjacent bike/pedestrian
path, retail on the dominant corner, and live/work units on the ground floor.
Surrounding properties include a surface parking lot and the Griffin Foundation on
the West, the Mason Street Corridor on the East and CSURF property to the South.
The North boundary is bordered by West Prospect Road and is not affected by our
projects location.
local businesses and retail locations are the only occupied structures which are
adjacent to our project. Our project has negligent visual impact on the local
businesses. Vista views towards the mounatins has minimal impact based on the
location of the proposed structure and the existing large trees.
No existing views from the East, North or South are affected by our proposal.
226 Remington St.
S
W
C
C
S
W
W
E
W
W
S
W
W
BV
W
W
W
W
94.0
89.5 sump
93.0
93.15
97.0 96.4
96.6
S
W
C
C
C
C
S
C
BV
W
W
WEST PROSPECT
ROAD
6' UTILITY AND
DRAINAGE EASEMENT
SHADOW ANALYSIS SUMMARY:
r4 Architects has developed a shadow analysis based on the available information
for assumed locations and construction of adjacent structures and the observed
grades. Winter shadow conditions are based on December 21st at incremental
times, 9am, 12 noon, and 3pm.
Based on our analysis, the proposed project does NOT have an adverse affect on
adjacent public and private property as defined in the LUC. Our shadow impact
occurs each day during limited winter months on west Prospect road to the North.
Retail buildings on the north side of Prospect are the only occupied structure within
our cast shadows and are minimally impacted during short periods of time during
winter months. Our proposed project has negligent impact during portions of 3
winter months and at limited hours in early morning and late afternoon. Storefront
windows on the ground floor are intermittently in shadow beginning at 9am and
progressing across the builing as the sun changes position. We will not have
impact and will have adequate solar gain in the morning and early afternoon in these
months. The proposed project has been sited to the southern property line and
provides proper setbacks along Prospect road.
General Note:
Neighboring structures shown in the background have been modeled using the best
information available to us at the time. r4 Architects has used aerial photographs to
determine adjacencies of the occupied buildings. In addition, we have replicated the
building massing and fenestration from photographs, site observation and traditional
construction practices for height and roof slope.
DESIGN CONSIDERATIONS TO MINIMIZE VISUAL AND SHADOW IMPACTS ON
NEIGHBORING PROPERTIES
Design considerations to minimize our solar and visual impact on neighboring
properties include the following:
• Incorporating substantial building setbacks on the North property line to
maximize pedestrian interaction with the site.
• A public plaza has been designed along the north and east frontages to
provide a pedestrian zone between sidewalks and the existing bike path.
• Oportunities for public art have been identified along the north frontage.
• Unit design to incorporate the use of HVAC units to be located on the
rooftop within a mechanical well surrounded by a mansard roof to
completely screen all mechanical equipment.
• Changes in massing and material are incorporated on all fasades for
Architectural and visual intrest.
• Contextural roof forms using flat and sloped roofs with both metal and
asphalt roofing styles.
• Use of pedestrian scale canopies, entry canopies and intricate deck railings
to provide visibility out and intrest to our project.
PROJECT SUMMARY:
r4 Architects has developed a visual analysis that identifies the extent to which
existing views may be blocked. Our project is infill on an site with an existing small
coffee shop along the new Mason Street corridor. Our project is placed five feet off
the south property boundary to allow southern windows and provide a pedestrian
plaza along Prospect Road. The project will have a defined plaza and patio that front
both Prospect Road and the Mason Street corridor. This activity node contains a
provisions for a local bus stop, direct access to the MAX, adjacent bike/pedestrian
path, retail on the dominant corner, and live/work units on the ground floor.
Surrounding properties include a surface parking lot and the Griffin Foundation on
the West, the Mason Street Corridor on the East and CSURF property to the South.
The North boundary is bordered by West Prospect Road and is not affected by our
projects location.
local businesses and retail locations are the only occupied structures which are
adjacent to our project. Our project has negligent visual impact on the local
businesses. Vista views towards the mounatins has minimal impact based on the
location of the proposed structure and the existing large trees.
No existing views from the East, North or South are affected by our proposal.
Existing Railroad Tracks
Existing Bike/Pedestrian Path
3D View 'A'
3D View 'B'
Proposed 291 West Prospect Road
West Prospect Road
Existing Railroad Crossing
Mechanical
Well
Existing
Action
Locksmith
Prospector
Shops
226 Remington St.
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4arch.com
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
Dohn Construction General Contractor
Prospect Station, LLC Owner
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
Larsen Structural Design Structural Engineer
AE Associates Mechanical Engineer
APS Electrical Engineer
ARCHITECTS
r4arch.com
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
19 Old Town Square, Suite 238
Fort Collins, CO 80524
(970) 568-3355
Contact: Blake Larsen
Email: blake@larsensd.com
5587 West 19th Street
Greeley, CO 80634
(970) 330-5587
Contact: Alicia Thorpe
Email: alicia.thorpe@aeassociates.net
6931 Broadway
Denver, CO 80221
(303) 287-8091
Contact: Chuck Polson
Email: chuck@apsinc.biz
TB Group Landscape Architect
444 Mountain Ave.
Berthoud, CO 80513
(970) 532-5891
Contact: Cathy Mathis
Email: cathy@tbgroup.us
Interwest Consultants Civil Engineer
1218 Ash Street
Windsor, CO 80550
(970) 674-3300
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Prospect
Station
1 Final Plan Submittal 7/3/2013
Final Plan Submittal
SA
MR
- A7 -
Visual Analysis
221 Prospect Road
Fort Collins, CO 80526
2012-24
Shadow & Visual Analysis General Notes
1" = 30'-0"
6
Architectural Site Plan
0 30 60 90 120
3/16" = 1'-0"
1
View 'A' Westbound Prospect - EXISTING
3/16" = 1'-0"
2
View 'A' Westbound Prospect - PROPOSED
1/8" = 1'-0"
3
View 'B' Looking Northwest - EXISTING
1/8" = 1'-0"
4
View 'B' Looking Northwest - PROPOSED
1" = 10'-0"
5
North Elevation - Landscaped
No. Description Date
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4arch.com
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
Dohn Construction General Contractor
Prospect Station, LLC Owner
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
Larsen Structural Design Structural Engineer
AE Associates Mechanical Engineer
APS Electrical Engineer
ARCHITECTS
r4arch.com
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
19 Old Town Square, Suite 238
Fort Collins, CO 80524
(970) 568-3355
Contact: Blake Larsen
Email: blake@larsensd.com
5587 West 19th Street
Greeley, CO 80634
(970) 330-5587
Contact: Alicia Thorpe
Email: alicia.thorpe@aeassociates.net
6931 Broadway
Denver, CO 80221
(303) 287-8091
Contact: Chuck Polson
Email: chuck@apsinc.biz
TB Group Landscape Architect
444 Mountain Ave.
Berthoud, CO 80513
(970) 532-5891
Contact: Cathy Mathis
Email: cathy@tbgroup.us
Interwest Consultants Civil Engineer
1218 Ash Street
Windsor, CO 80550
(970) 674-3300
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Prospect
Station
1 Final Plan Submittal 7/3/2013
Final Plan Submittal
SA
MR
- A6 -
Shadow Analysis
221 Prospect Road
Fort Collins, CO 80526
2012-24
Shadow & Visual Analysis General Notes Winter 9am
Winter 12pm
Winter 3pm
Summer 9am
Summer 12pm
Summer 3pm
No. Description Date
Field
W1
Accent
8
W2
Field
W3
W1
Accent
R1
R2
W1
Field
11
9
1
W4
W2
Accent
W2
Field
9
W3
R1
R2
12
4.5
12
4.5
W2
Field
W3
W1
Accent
W1
Field
W1
Accent
W1
Field
W4
7
F3
F1
Foreground Background
W2
Accent
13
Open Open Open
W2
Accent
W2
Field
5
7
Field Brick Veneer: Standard, running bond
Mortar: Integral color mortar from Davis Color selection
W1
Field
Miscellaneous building materials/finishes:
Vinyl Windows:
Atrium sliding, fixed and sliding windows, 'White'
Patio Doors:
Atrium sliding patio doors, 'White'
Aluminum Storefronts:
Doorways: Tubelite medium stile, Medium Bronze aluminum finish
Garage Openings:
Steel tube frame, painted to match adjacent storefront systems
Deck railing, guards and embeds:
Powder coated, Bronze to match Storefront bronze
Steel roof brackets:
Painted, Bronze to match Storefront bronze
Doors, gates and misc.:
Painted, Bronze to match Storefront bronze
Exposed Vents, flues, conduit, boxes and meters:
Painted, to match adjacent materials.
Accent Brick Veneer: Standard, running bond
Mortar: Integral color mortar from Davis Color selection
W1
Accent
W2 Field color: Senergy hard coat stucco, Light Color TBD
Field
Accent color: Senergy hard coat stucco, Dark Earthtone
Color TBD
W2
Accent
W3painted Board & Batten: Hardi panel,
W4 4" Natural Stone Band
Pre-finished Metal Standing seam: Berridge 'Copper Cote',
24ga. Brake Metal Shapes: Berridge 'Copper Cote', 24 ga.
R1
Asphalt High profile shingles: All roof penetrations and vents
painted to match shingle.
R2
Roofing Materials:
Wall Materials:
F1 Concrete Slab-on-Grade:
Concrete walks:
Standard gray w/ light broom finish
F2
STRD.
Floor Materials:
Concrete walks:
Integral colored w/ light broom finish, Color TBD Davis Colors
F2
Color
Exterior Decks:
5/4" Trex deck material over Pressure treated joist framing
F3
TPO Membrane Roof: Tan with SRI to meet LEED
Standards
R3
2nd Floor:
Concrete floor over metal deck, 3-hour rated assembly
F4
Wood Floor Structure:
1-1/2" Gyp-crete over 3/4" substrate over TJI floor joists
per Struct.
F5
* For full system notes refer to A0.2
1
Architectural steel canopy with full cut-off wall wash light
fixture to accentuate public art, Typical at three (3) locations
on North wall.
2 Proposed Public Art Location for separate approval.
3 Future Transfort Public Bus Stop with shelter, by others
4
Painted steel frame with metal screen infill to match adjacent
storefront windows. Three (3) locations into open parking
garage, Typ.
5
Decorative Steel handrail painted. Potential for public art
opportunity.
Keynotes:
6 Fixed Bicycle parking rack
7 Gas meters
8 New electrical switch gear or pad mount transformer
9 Suspended parking lot signage.
10 Hanging Bike racks: Covered, and secured.
11 Steel tube roof brace kicker, painted bronze.
Exterior retail signage shown for representation only, not for
current approval. Sign submittals & permits by others.
12
Mechanical well with mansard roof all around to fully screen
all mechanical equipment.
13
14 Electrical meter stacks for each unit, paint to match adjacent wall.
226 Remington St.
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4arch.com
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
Dohn Construction General Contractor
Prospect Station, LLC Owner
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
Larsen Structural Design Structural Engineer
AE Associates Mechanical Engineer
APS Electrical Engineer
ARCHITECTS
r4arch.com
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
19 Old Town Square, Suite 238
Fort Collins, CO 80524
(970) 568-3355
Contact: Blake Larsen
Email: blake@larsensd.com
5587 West 19th Street
Greeley, CO 80634
(970) 330-5587
Contact: Alicia Thorpe
Email: alicia.thorpe@aeassociates.net
6931 Broadway
Denver, CO 80221
(303) 287-8091
Contact: Chuck Polson
Email: chuck@apsinc.biz
TB Group Landscape Architect
444 Mountain Ave.
Berthoud, CO 80513
(970) 532-5891
Contact: Cathy Mathis
Email: cathy@tbgroup.us
Interwest Consultants Civil Engineer
1218 Ash Street
Windsor, CO 80550
(970) 674-3300
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Prospect
Station
1 Final Plan Submittal 7/3/2013
Final Plan Submittal
SA
MR
- A5 -
Exterior Elevations
221 Prospect Road
Fort Collins, CO 80526
2012-24
1/8" = 1'-0"
1
East Building Elevation
1/8" = 1'-0"
2
West Building Elevation
Planning Keynotes
No. Description Date
Accent
11
Background Foreground
12
2 2
Beyond
5
Beyond
Level 1 - Ground
Floor
0' - 0"
Roof
43' - 1 1/8"
Level 2
14' - 0"
Level 3
24' - 10 7/8"
Plate Height
34' - 0"
1 2 3 4 5 6 7 8 9 10 11 12
W1
Field
W1
Accent
W1
Accent
1
W2
Accent
W2
Field
R2
R1
W1
Field
12
4.5
12
3
7
9
46' - 4" Roof Peak
W3
W2
Field
W3
W3
W1
Field
W1
Accent
W1
Field
W1
Accent
F4
F3
11
Background Foreground
Easement
8
Open Open
Open
Open Open Open
W2
Accent
W2
Field
13
W3
W2
Accent
W3 W2
Accent
Open
R1
W2
Field
W2
Field
W2
Field
11
5
Field Brick Veneer: Standard, running bond
Mortar: Integral color mortar from Davis Color selection
W1
Field
Miscellaneous building materials/finishes:
Vinyl Windows:
Atrium sliding, fixed and sliding windows, 'White'
Patio Doors:
Atrium sliding patio doors, 'White'
Aluminum Storefronts:
Doorways: Tubelite medium stile, Medium Bronze aluminum finish
Garage Openings:
Steel tube frame, painted to match adjacent storefront systems
Deck railing, guards and embeds:
Powder coated, Bronze to match Storefront bronze
Steel roof brackets:
Painted, Bronze to match Storefront bronze
Doors, gates and misc.:
Painted, Bronze to match Storefront bronze
Exposed Vents, flues, conduit, boxes and meters:
Painted, to match adjacent materials.
Accent Brick Veneer: Standard, running bond
Mortar: Integral color mortar from Davis Color selection
W1
Accent
W2 Field color: Senergy hard coat stucco, Light Color TBD
Field
Accent color: Senergy hard coat stucco, Dark Earthtone
Color TBD
W2
Accent
W3painted Board & Batten: Hardi panel,
W4 4" Natural Stone Band
Pre-finished Metal Standing seam: Berridge 'Copper Cote',
24ga. Brake Metal Shapes: Berridge 'Copper Cote', 24 ga.
R1
Asphalt High profile shingles: All roof penetrations and vents
painted to match shingle.
R2
Roofing Materials:
Wall Materials:
F1 Concrete Slab-on-Grade:
Concrete walks:
Standard gray w/ light broom finish
F2
STRD.
Floor Materials:
Concrete walks:
Integral colored w/ light broom finish, Color TBD Davis Colors
F2
Color
Exterior Decks:
5/4" Trex deck material over Pressure treated joist framing
F3
TPO Membrane Roof: Tan with SRI to meet LEED
Standards
R3
2nd Floor:
Concrete floor over metal deck, 3-hour rated assembly
F4
Wood Floor Structure:
1-1/2" Gyp-crete over 3/4" substrate over TJI floor joists
per Struct.
F5
* For full system notes refer to A0.2
W1
Field
W1
Field
W1
Accent
W1
Accent
W2
Field
W2
Accent
1
4
W1
Accent
W1
Accent
W4
2
1
Architectural steel canopy with full cut-off wall wash light
fixture to accentuate public art, Typical at three (3) locations
on North wall.
2 Proposed Public Art Location for separate approval.
3 Future Transfort Public Bus Stop with shelter, by others
4
Painted steel frame with metal screen infill to match adjacent
storefront windows. Three (3) locations into open parking
garage, Typ.
5
Decorative Steel handrail painted. Potential for public art
opportunity.
Keynotes:
6 Fixed Bicycle parking rack
7 Gas meters
8 New electrical switch gear or pad mount transformer
9 Suspended parking lot signage.
10 Hanging Bike racks: Covered, and secured.
11 Steel tube roof brace kicker, painted bronze.
Exterior retail signage shown for representation only, not for
current approval. Sign submittals & permits by others.
12
Mechanical well with mansard roof all around to fully screen
all mechanical equipment.
13
14 Electrical meter stacks for each unit, paint to match adjacent wall.
226 Remington St.
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4arch.com
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
Dohn Construction General Contractor
Prospect Station, LLC Owner
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
Larsen Structural Design Structural Engineer
AE Associates Mechanical Engineer
APS Electrical Engineer
ARCHITECTS
r4arch.com
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
19 Old Town Square, Suite 238
Fort Collins, CO 80524
(970) 568-3355
Contact: Blake Larsen
Email: blake@larsensd.com
5587 West 19th Street
Greeley, CO 80634
(970) 330-5587
Contact: Alicia Thorpe
Email: alicia.thorpe@aeassociates.net
6931 Broadway
Denver, CO 80221
(303) 287-8091
Contact: Chuck Polson
Email: chuck@apsinc.biz
TB Group Landscape Architect
444 Mountain Ave.
Berthoud, CO 80513
(970) 532-5891
Contact: Cathy Mathis
Email: cathy@tbgroup.us
Interwest Consultants Civil Engineer
1218 Ash Street
Windsor, CO 80550
(970) 674-3300
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Prospect
Station
1 Final Plan Submittal 7/3/2013
Final Plan Submittal
SA
MR
- A4 -
Exterior Elevations
221 Prospect Road
Fort Collins, CO 80526
2012-24
1/8" = 1'-0"
1
North Building Elevation
1/8" = 1'-0"
2
South Building Elevation
1/4" = 1'-0"
3
Detailed North Elevation
No. Description Date
MR
- A3 -
3D Prespectives
221 Prospect Road
Fort Collins, CO 80526
2012-24
2
Northwest 3D View
3
Northeast 3D View
1
Southwest 3D View
No. Description Date
2 Bedroom
Unit 211
Studio
Unit 212
Studio
Unit 213
Studio
Unit 215
Studio
F4 F4
F3
F3
F3
Unit 214
1 Bedroom
Field Brick Veneer: Standard, running bond
Mortar: Integral color mortar from Davis Color selection
W1
Field
Miscellaneous building materials/finishes:
Vinyl Windows:
Atrium sliding, fixed and sliding windows, 'White'
Patio Doors:
Atrium sliding patio doors, 'White'
Aluminum Storefronts:
Doorways: Tubelite medium stile, Medium Bronze aluminum finish
Garage Openings:
Steel tube frame, painted to match adjacent storefront systems
Deck railing, guards and embeds:
Powder coated, Bronze to match Storefront bronze
Steel roof brackets:
Painted, Bronze to match Storefront bronze
Doors, gates and misc.:
Painted, Bronze to match Storefront bronze
Exposed Vents, flues, conduit, boxes and meters:
Painted, to match adjacent materials.
Accent Brick Veneer: Standard, running bond
Mortar: Integral color mortar from Davis Color selection
W1
Accent
W2 Field color: Senergy hard coat stucco, Light Color TBD
Field
Accent color: Senergy hard coat stucco, Dark Earthtone
Color TBD
W2
Accent
W3painted Board & Batten: Hardi panel,
W4 4" Natural Stone Band
Pre-finished Metal Standing seam: Berridge 'Copper Cote',
24ga. Brake Metal Shapes: Berridge 'Copper Cote', 24 ga.
R1
Asphalt High profile shingles: All roof penetrations and vents
painted to match shingle.
R2
Roofing Materials:
Wall Materials:
F1 Concrete Slab-on-Grade:
Concrete walks:
Standard gray w/ light broom finish
F2
STRD.
Floor Materials:
Concrete walks:
Integral colored w/ light broom finish, Color TBD Davis Colors
F2
Color
Exterior Decks:
5/4" Trex deck material over Pressure treated joist framing
F3
TPO Membrane Roof: Tan with SRI to meet LEED
Standards
R3
2nd Floor:
Concrete floor over metal deck, 3-hour rated assembly
F4
Wood Floor Structure:
1-1/2" Gyp-crete over 3/4" substrate over TJI floor joists
per Struct.
F5
* For full system notes refer to A0.2
1
Architectural steel canopy with full cut-off wall wash light
fixture to accentuate public art, Typical at three (3) locations
on North wall.
2 Proposed Public Art Location for separate approval.
3 Future Transfort Public Bus Stop with shelter, by others
4
Painted steel frame with metal screen infill to match adjacent
storefront windows. Three (3) locations into open parking
garage, Typ.
5
Decorative Steel handrail painted. Potential for public art
opportunity.
Keynotes:
6 Fixed Bicycle parking rack
7 Gas meters
8 New electrical switch gear or pad mount transformer
9 Suspended parking lot signage.
10 Hanging Bike racks: Covered, and secured.
11 Steel tube roof brace kicker, painted bronze.
Exterior retail signage shown for representation only, not for
current approval. Sign submittals & permits by others.
12
Mechanical well with mansard roof all around to fully screen
all mechanical equipment.
13
14 Electrical meter stacks for each unit, paint to match adjacent wall.
226 Remington St.
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4arch.com
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
Dohn Construction General Contractor
Prospect Station, LLC Owner
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
Larsen Structural Design Structural Engineer
AE Associates Mechanical Engineer
APS Electrical Engineer
ARCHITECTS
r4arch.com
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
19 Old Town Square, Suite 238
Fort Collins, CO 80524
(970) 568-3355
Contact: Blake Larsen
Email: blake@larsensd.com
5587 West 19th Street
Greeley, CO 80634
(970) 330-5587
Contact: Alicia Thorpe
Email: alicia.thorpe@aeassociates.net
6931 Broadway
Denver, CO 80221
(303) 287-8091
Contact: Chuck Polson
Email: chuck@apsinc.biz
TB Group Landscape Architect
444 Mountain Ave.
Berthoud, CO 80513
(970) 532-5891
Contact: Cathy Mathis
Email: cathy@tbgroup.us
Interwest Consultants Civil Engineer
1218 Ash Street
Windsor, CO 80550
(970) 674-3300
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Prospect
Station
1 Final Plan Submittal 7/3/2013
Final Plan Submittal
SA
MR
- A2 -
Levels 2 & 3, Typical
Residential Floor Plan
221 Prospect Road
Fort Collins, CO 80526
2012-24
1" = 10'-0"
1
Planning - Typical Residential Floor Plan
Planning Keynotes
No. Description Date
F2
STRD.
F2
STRD.
F2
STRD.
F2
STRD.
F2
STRD.
F2
STRD.
F2
Color
Primary Entrance
Retail
Primary Entrance
Multi-Family
West Prospect Road
6
Fixed Bike Spaces
19 Spaces Required: 24 Spaces provided
Bollard Racks for Retail
4 Spaces Required 4 Spaces provided
Bike spaces in the Right of Way (Not counted towards Req's)
None Required 8 Spaces provided
Secure/enclosed Bike Storage for Tenants (See A2 for breakdown)
30 Spaces Required 30 Spaces provided
Vehicle Parking Counts Bicycle Parking Counts
C C C C
C C C
C C C
Ramp
DN
1
Ramp
DN
Ramp
DN
Ramp
DN
Pipe Bollards
20' - 0"
WaterQuality Water
Quality
Pipe Bollards
14
6
6
6
7
6
6
Field Brick Veneer: Standard, running bond
Mortar: Integral color mortar from Davis Color selection
W1
Field
Miscellaneous building materials/finishes:
Vinyl Windows:
Atrium sliding, fixed and sliding windows, 'White'
Patio Doors:
Atrium sliding patio doors, 'White'
Aluminum Storefronts:
Doorways: Tubelite medium stile, Medium Bronze aluminum finish
Garage Openings:
Steel tube frame, painted to match adjacent storefront systems
Deck railing, guards and embeds:
Powder coated, Bronze to match Storefront bronze
Steel roof brackets:
Painted, Bronze to match Storefront bronze
Doors, gates and misc.:
Painted, Bronze to match Storefront bronze
Exposed Vents, flues, conduit, boxes and meters:
Painted, to match adjacent materials.
Accent Brick Veneer: Standard, running bond
Mortar: Integral color mortar from Davis Color selection
W1
Accent
W2 Field color: Senergy hard coat stucco, Light Color TBD
Field
Accent color: Senergy hard coat stucco, Dark Earthtone
Color TBD
W2
Accent
W3painted Board & Batten: Hardi panel,
W4 4" Natural Stone Band
Pre-finished Metal Standing seam: Berridge 'Copper Cote',
24ga. Brake Metal Shapes: Berridge 'Copper Cote', 24 ga.
R1
Asphalt High profile shingles: All roof penetrations and vents
painted to match shingle.
R2
Roofing Materials:
Wall Materials:
F1 Concrete Slab-on-Grade:
Concrete walks:
Standard gray w/ light broom finish
F2
STRD.
Floor Materials:
Concrete walks:
Integral colored w/ light broom finish, Color TBD Davis Colors
F2
Color
Exterior Decks:
5/4" Trex deck material over Pressure treated joist framing
F3
TPO Membrane Roof: Tan with SRI to meet LEED
Standards
R3
2nd Floor:
Concrete floor over metal deck, 3-hour rated assembly
F4
Wood Floor Structure:
1-1/2" Gyp-crete over 3/4" substrate over TJI floor joists
per Struct.
F5
* For full system notes refer to A0.2
1
Architectural steel canopy with full cut-off wall wash light
fixture to accentuate public art, Typical at three (3) locations
on North wall.
2 Proposed Public Art Location for separate approval.
3 Future Transfort Public Bus Stop with shelter, by others
4
Painted steel frame with metal screen infill to match adjacent
storefront windows. Three (3) locations into open parking
garage, Typ.
5
Decorative Steel handrail painted. Potential for public art
opportunity.
Keynotes:
6 Fixed Bicycle parking rack
7 Gas meters
8 New electrical switch gear or pad mount transformer
9 Suspended parking lot signage.
10 Hanging Bike racks: Covered, and secured.
11 Steel tube roof brace kicker, painted bronze.
Exterior retail signage shown for representation only, not for
current approval. Sign submittals & permits by others.
12
Mechanical well with mansard roof all around to fully screen
all mechanical equipment.
13
14 Electrical meter stacks for each unit, paint to match adjacent wall.
226 Remington St.
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4arch.com
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
Dohn Construction General Contractor
Prospect Station, LLC Owner
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
Larsen Structural Design Structural Engineer
AE Associates Mechanical Engineer
APS Electrical Engineer
ARCHITECTS
r4arch.com
2642 Midpoint Drive, Unit A
Fort Collins, CO 80525
(970)490-1855
Contact: Doug Dohn
Email: ddohn@dohnconstruction.com
19 Old Town Square, Suite 238
Fort Collins, CO 80524
(970) 568-3355
Contact: Blake Larsen
Email: blake@larsensd.com
5587 West 19th Street
Greeley, CO 80634
(970) 330-5587
Contact: Alicia Thorpe
Email: alicia.thorpe@aeassociates.net
6931 Broadway
Denver, CO 80221
(303) 287-8091
Contact: Chuck Polson
Email: chuck@apsinc.biz
TB Group Landscape Architect
444 Mountain Ave.
Berthoud, CO 80513
(970) 532-5891
Contact: Cathy Mathis
Email: cathy@tbgroup.us
Interwest Consultants Civil Engineer
1218 Ash Street
Windsor, CO 80550
(970) 674-3300
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Prospect
Station
1 Final Plan Submittal 7/3/2013
Final Plan Submittal
SA
MR
- A1 -
Ground Floor Plan
221 Prospect Road
Fort Collins, CO 80526
2012-24
1" = 10'-0"
1
Planning - Ground Floor Plan
Planning Keynotes
No. Description Date