Loading...
HomeMy WebLinkAboutCANYON PLACE (331 S. MELDRUM) - FDP - FDP120024 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSCOLLEGE AVE OAK ST. OLIVE ST. MAGNOLIA ST. MULBERRY ST. MYRTLE ST. LAPORTE AVE MAPLE ST. CHERRY ST. MASON ST. HOWES ST. MELDRUM ST. SHERWOOD ST. WHITCOMB ST. LOOMIS ST. REMMINGTON ST. MATHEWS ST. PETERSON ST. WHEDBEE ST. SMITH ST. STOVER ST. COWAN ST. MOUNTAIN AVE. WALNUT ST.JEFFERSON ST. CANYON AVE. RIVERSIDE AVE. C0.00 COVER SHEET N.A. D. Fry N.A. C0.00 COVER SHEET C0.01 GENERAL AND CONSTRUCTION NOTES C3.00 GRADING PLAN EXISTING CONDITIONS AND DEMOLITION PLAN DEVELOPER/APPLICANT Blue Ocean Enterprises, Inc. 416 West Oak Street Fort Collins, Colorado 80521 (970) 494-5422 SITE ENGINEER Northern Engineering Services, Inc. Nick Haws, PE, LEED, AP 200 South College Avenue, Suite 10 Fort Collins, CO 80524 (970) 221-4158 C1.00 DECEMBER, 2012 SURVEYOR Northern Engineering Services, Inc. Gary Gilliland, PLS 200 South College Avenue, Suite 10 Fort Collins, CO 80524 (970) 221-4158 LOTS 1, 2 AND 3, BLOCK 83 OF THE PLAT OF THE TOWN OF FORT COLLINS LOCATED IN THE SOUTHEAST QUARTER OF SECTION 11, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO UTILITY PLANS FOR No. Revisions: By: Date: C0.01 NOTES GENERAL AND CONSTRUCTION N.A. N.A. N.A. No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. VAULT CABLE / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 20' 35.5' 9' (TYP.) 19' (TYP.) 26.9' 9' (TYP.) 19' (TYP.) 32' 24' 24' COLLEGE AVE OAK ST. OLIVE ST. MAGNOLIA ST. MULBERRY ST. MYRTLE ST. LAPORTE AVE MAPLE ST. CHERRY ST. MASON ST. HOWES ST. MELDRUM ST. SHERWOOD ST. WHITCOMB ST. LOOMIS ST. REMMINGTON ST. MATHEWS ST. PETERSON ST. WHEDBEE ST. SMITH ST. STOVER ST. COWAN ST. MOUNTAIN AVE. WALNUT ST.JEFFERSON ST. CANYON AVE. RIVERSIDE AVE. SITE REVIEWED BY: G. Gilliland DESIGNED BY: DRAWN BY: SCALE: DATE: 12/26/12 PROJECT: 838-002 Sheet Of 2 Sheets CANYON PLACE CANYON PLACE CANYON PLACE NOTICE : According to Colorado law you must commence any legal action based upon any defect in this survey within three years after you discover such defect. In no event may any action based upon any defect in this survey be commenced more than ten years after the date of the certificate shown hereon. RANGE: TOWNSHIP: SECTION: 200 S���� C������ A�����, S���� 10 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� MAINTENANCE GUARANTEE: The Owner hereby warrants and guarantees to the City, for a period of two (2) years from the date of completion and first acceptance by the City of the improvements warranted hereunder, the full and complete maintenance and repair of the improvements to be constructed in 192.87' LOT 1 25,999 sq.ft. 0.597 ac LOT 2 28,226 sq.ft. 0.648 ac S00�15'07"W 329.18' N89�42'48"W 329.46' N44�40'41"W 42.44' 279.23' N89�43'31"W 65.02' N44�40'41"W 49.57' N00�22'17"E 27.17' N89�37'43"W 10.50' N44�38'31"W 32.24' S46�09'48"W 13.24' S43�50'12"E 4.80' S46�09'48"W 23.09' Delta= 89�09'31" R=5.00' L=7.78' Dir= N89�15'26"W Chord= 7.02' 49.95' 25' ACCESS EASEMENT 231.39' 25.00' OWNER WEIDERSPON RICHARDS REC No. 17030327 OWNER FIELDS JACQUELINE REC No. 20030121375 OWNER CANINO CLYDE MICHAEL REC No. 20090044999 OWNER OPSAND-McCHESNEY RENTALS REC No. 2002098753 OWNER LAY ROBERT W/ SANDRA L REC No. 20060071833 OWNER SCHNEIDER BERTAM REV TRUST SCHNEIDER SANDRA D TRUSTEE REC No. 2001100060 UNITED STATES POSTAL SERVICE SIDEWALK (TO BE REMOVED) CONTROL IRR CONTROL IRR � ELEC BRKR � � ELEC T ELEC T � VAULT F.O. VAULT F.O. CONTROL IRR CONTROL IRR VAULT CABLE VAULT ELEC G G G G G G G G G G G G T T T T T T T T T T T FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E CONTROL IRR CONTROL IRR � ELEC T ELEC T VAULT F.O. VAULT F.O. CONTROL IRR CONTROL IRR VAULT CABLE VAULT ELEC G G G G G G G G G G T T T T FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E E E E E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CONTROL IRR CONTROL IRR � CONTROL IRR CONTROL IRR VAULT CABLE CONTROL IRR CONTROL IRR ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST EXISTING OFFICE BUILDING FFE=97.55 VAULT CABLE ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST EXISTING OFFICE BUILDING CANYON AVENUE (100' RIGHT-OF-WAY) W. MAGNOLIA STREET (100' RIGHT-OF-WAY) S. MELDRUM STREET (100' RIGHT-OF-WAY) EXISTING BANK BUILDING PROPOSED OFFICE BUILDING 3795 - 4998.18 NGVD 29 3697 - 4997.61 NGVD 29 3490 - 4997.27 NGVD 29 3402 - 4996.70 NGVD 29 3957 BFE = 4997 NGVD 29 BFE = 4998 NGVD 29 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C5.00 SITE DETAILS NA NA NA K��� ����'������. C��� ������ ��� ���. R No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� 6" 2"R. 2" 6" 6" 12" 1 1/2"R. 2'-6" 6" 4 1/2" 30" 9" R 0.5" 4.5" 18" 3.63" 21.75" R 0.13" 7" 2" 3.75" C5.01 UTILITY DETAILS SITE AND NA NA NA City UTILITY of Fort PLAN Collins, APPROVAL Colorado Date Date Date Date Date Date APPROVED: City Engineer Traffic Engineer Parks & Recreation Stormwater Utility Water & Wastewater Utility CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: K��� ����'� �����. C��� ������ ��� ���. R No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� PIPE C5.02 CONTROL DETAILS DRAINAGE AND EROSION NA NA NA City UTILITY of Fort PLAN Collins, APPROVAL Colorado Date Date Date Date Date Date APPROVED: City Engineer Traffic Engineer Parks & Recreation Stormwater Utility Water & Wastewater Utility CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� VEHICLE TRACKING CONTROL PAD SHALL BE LOCATED AT EVERY ACCESS POINT TO THE CONSTRUCTION SITE. A SIGN SHALL BE PLACED NEXT TO THE VEHICLE TRACKING CONTROL PAD TO DESIGNATE THE LOCATION AS THE CONSTRUCTION ENTRANCE/EXIT. VEHICLE TRACKING CONTROL PADS SHALL CONSIST OF HARD, DENSE, DURABLE STONE, ANGULAR IN SHAPE AND RESISTANT TO WEATHERING. ROUNDED STONE (i.e. RIVER ROCK AND COBBLES) SHALL NOT BE USED. THE STONES SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 6" DIAMETER. THE STONES SHALL HAVE A SPECIFIC GRAVITY OF AT LEAST 2.6. CONTROL OF GRADATION WILL BE BY VISUAL INSPECTION. ANY CRACKED OR DAMAGED CURB AND GUTTER AND SIDEWALK SHALL BE REPLACED BY CONTRACTOR. {INSTALLATION NOTES: }1. 2. 3. 4. CONTRACTOR SHALL INSPECT VEHICLE TRACKING CONTROL PAD DAILY. ROCK SURFACE SHALL BE CLEAN AND LOOSE ENOUGH TO RUT SLIGHTLY UNDER WHEEL LOADS AND CAUSE LOOSE ROCK TO DISLODGE MUD FROM TIRES. WHEN ROCK BECOMES COMPACTED OR FILLED WITH SEDIMENT SO THAT THE EFFECTIVENESS OF THE PAD IS DIMINISHED, CONTRACTOR SHALL RIP, TURN OVER, OR OTHERWISE LOOSEN ROCK, PLACE ADDITIONAL NEW ROCK, OR REPLACE WITH NEW ROCK AS NECESSARY TO RESTORE EFFECTIVENESS. SEDIMENT AND OTHER MATERIAL SPILLED, DROPPED OR TRACKED ONTO PAVED SURFACES SHALL BE REMOVED IMMEDIATELY OR BY THE END OF EACH WORKING DAY. VEHICLE TRACKING CONTROL PAD SHALL BE REMOVED AT THE END OF CONSTRUCTION. THE AREA SHOULD BE TOPSOILED, SEEDED, CRIMPED, AND MULCHED OR OTHERWISE {STABILIZED. MAINTENANCE NOTES: }1. 2. 3. VT 3" - 6" ROCK CONSTRUCTION FENCE, TYP., TO DISCOURAGE VEHICLE ACCESS EXCEPT AT VTC SIGN "CONSTRUCTION ENTRANCE" R=5' PAVED SURFACE 20' MIN. A 10% MAX. SECTION A NO MATERIALS INCLUDING 2x4'S, PIPES, DIRT, GRAVEL OR ASPHALT, SHALL BE PLACED IN GUTTER TO FACILITATE MOUNTING CURB; HOWEVER, CURB MAY BE CUT DOWN TO A HEIGHT OF 2" OR HIGHER FOR EASIER ACCESS AND REPLACED AT PROJECT COMPLETION. OTHER ACCESS DEVICES MAY BE USED AS ACCEPTED BY THE CITY. 3" - 6" ROCK %PLAN CURB CUT VT 50' MIN. 2" MIN. 6" MIN. 6" MIN. VEHICLE TRACKING CONTROL PAD SW-15 DRAWING DRAWING SW- PLAN VIEW APRON SILT DIKE UNIT FLOW STAPLES (18" TYP.)DIKE SECTION INTO TRENCH POINT A CROSS SECTION PROFILE POINT B DIKE SECTION APRON ANCHORED 6" x 6" TRENCH FLOW NOTE: STAPLES STAPLES 8" (TYP) (PER SPECIFICATIONS 02375) FILTER GEOTEXTILE DITCH POINT D POINT C 6" (MIN) PROFILE PROFILE VIEW ALONG DITCH FLOWLINE 24" 8' 2:1 OR FLATTER C & D ARE OF EQUAL ELEVATION. L = THE DISTANCE SUCH THAT POINTS F DITCH 4"-6" ROCK FLOW SUBEXCAVATE BELOW FLOWLINE 6" MIN CROSS SECTION ROCK, WATTLE OR SILT DIKE POINT A MUST BE HIGHER THAN POINT B TO DIRECT WATER FLOW OVER THE DIKE BUT NOT AROUND THE ENDS OF THE DIKE SILT DIKE DETAIL {DITCH INSTALLATION} ENTRENCH 3" POINT A SECTION A-A POINTS A MUST BE HIGHER THAN POINT B PLAN VIEW POINT B POINT A WATTLE POINT A FLOW POINT B POINT A WATTLE DIKE {DITCH INSTALLATION} F A A THE CONTRACTOR SHALL INSPECT DIKES EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT UPSTREAM SEDIMENT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF DIKES SHALL BE REMOVED WHEN THE UPSTREAM SEDIMENT REACHES 1/2 OF THE DESIGN DEPTH. DIKES ARE TO REMAIN IN PLACE UNTIL THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED BY THE CITY. WHEN REINFORCED ROCK BERMS ARE REMOVED, ANY DISTURBED AREA SHALL BE SEEDED, CRIMPED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. {MAINTENANCE NOTES: }1. 2. 3. 4. W RD SD ROCK DIKE {DITCH INSTALLATION} STA %OR% STAKES SHOULD BE DRIVEN ACROSS FROM EACH OTHER AND ON EACH SIDE OF THE WATTLE. LEAVING 4"-6" OF STAKE PROTRUDING ABOVE THE WATTLE. BAILING WIRE OR NYLON ROPE SHOULD BE TIED TO THE STAKES ACROSS THE WATTLE. STAKES SHOULD THEN BE DRIVEN UNTIL THE BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG TO THE WATTLE. OR COMPACTED BACKFILL FLOW SILT FENCE FABRIC (ASTM D6461) ANCHORED IN TRENCH AND ATTACHED TO POST. 24" MIN 6' MAX FLOW TRENCH AND ATTACHED TO POST. 4"x4" TRENCH SILT FENCE FABRIC (ASTM D6461) ANCHORED IN 18" MIN 24" MIN 42" MIN POSTS {PREASSEMBLED SILT FENCE} JOIN FIRST ROTATE SECOND POSTS SHALL OVERLAP AT JOINTS SO THAT NO GAPS EXIST IN SILT FENCE. NOTE: THICKNESS OF GEOTEXTILE HAS BEEN EXAGGERATED. POST SHALL BE JOINED AS SHOWN, THEN ROTATED 180� IN DIRECTION SHOWN AND DRIVEN INTO THE GROUND. {SILT FENCE JOINTS} DRIVE POSTS VERTICALLY INTO THE GROUND TO A MINIMUM DEPTH OF 18". EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 4" DEEP ALONG THE LINE OF POSTS AND UPSLOPE FROM THE BARRIER. ANCHOR TRENCH SHALL BE EXCAVATED BY HAND, WITH TRENCHER, OR WITH SILT FENCE INSTALLATION MACHINE. NO ROAD GRADERS, BACKHOES, ETC. SHALL BE USED. NOT LESS THAN THE BOTTOM 1' OF THE SILT FENCE FABRIC SHALL BE BURIED IN THE TRENCH. THE TRENCH SHALL BE COMPACTED BY HAND, WITH "JUMPING JACK" OR BY WHEEL ROLLING. COMPACTION SHALL BE SUCH THAT THE SILT FENCE RESISTS BEING PULLED OUT OF ANCHOR TRENCH BY HAND. SILT FENCE INDICATED IN THE PLANS SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES. USE WOOD POSTS OR OTHER MATERIAL AS ACCEPTED BY THE CITY. {INSTALLATION NOTES: }1. 2. 3. 4. 5. 6. 7. THE CONTRACTOR SHALL INSPECT SILT FENCE EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT UPSTREAM SEDIMENT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM SEDIMENT REACHES A DEPTH OF 6". SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED BY THE CITY. IF ANY DISTURBED AREA EXISTS AFTER REMOVAL, IT SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. {MAINTENANCE NOTES: }1. 2. 3. SF 4" 4" MIN. MIN. SF SF {1 " x 1 " WOODEN FENCE POSTS} COMPACTED BACKFILL SILT FENCE DRAWING K��� ����'� �����. C��� ������ ��� ���. R BACK OF CURB EXTEND WALK 6" ON BOTH SIDES OF WALK SIDEWALK (TYP.) 3' 6" VARIES VARIES 3'-3" 8'-6" OPENING PLAN 3'-3" 3"A A C B B C METAL SIDEWALK CULVERT FOR VERT. CURB & GUTTER AND DETACHED SIDEWALK 1/28/09 D-10B TDC APPROVED: DATE: DETAIL DRAWN BY: CITY OF FORT COLLINS UTILITIES City of Fort Collins (TYP.) (TYP.) (TYP.) 3/8" BRASS SCREW 18"O.C. EDGE OF STREET 12" R 12" R SLOPE WITH COUNTERSUNK HEAD FLUSH WITH PLATE 5/8" GALV. STEEL PLATE SECTION A-A SECTION B-B VARIES 6" WITH COUNTERSUNK HEAD FLUSH 3/8" BRASS SCREW-18" O.C. ANCHOR 18" #3 REBAR 1" 6" 3"x2"x3/8" GALV. ANGLE 3'-0" 5/8" GALV. PLATE 2'-0" 1/4" WITH PLATE 3" 6" SLOPE PLATE TO 0.5% SLOPE (MIN.) VARIES MATCH SIDEWALK DETAIL 1 2'-0" O.C. SEE DETAIL 1 2 1 2 1 VARIES, SEE 5/8" GALV. STEEL PLATE 3"x2"x3/8" GALV. ANGLE BACK OF EDGE OF STREET CURB SLOPE VARIES PLANS EXPANSION EXPANSION MATERIAL MATERIAL 2'-0" SECTION C-C DEPRESSED VARIES #4@12" O.C. #4@12" #4@12" GUTTER STORMWATER CONSTRUCTION DETAILS DATE LAST REVISED: 5/29/09 SW-10 {SILT, ROCK OR WATTLE DIKE} 3/8 IN. BRASS SCREW-18 IN. O.C. W/ COUNTERSUNK HEAD FLUSH W/ PLATE 5/8 IN. GALVANIZED PLATE ANCHOR-18 IN. O.C. NO. 3 REBAR ANGLE GALVANIZED 3x2x3/8 IN. 3 IN. 2 FT. 0 IN. 3 IN. 3 IN. 2:1 SLOPE 3 FT. 0 IN. 5 FT. 6 IN. 4 5/8 IN. 6 IN. MIN. 7 1/2 IN. 2:1 SLOPE PLACE FIRST SCREW SEE DETAIL "A" OF PLATE 6 IN. FRONT EDGE 10 FT. 0 IN. RAISED PATTEREN NON-SKID GALV. 5/8 IN. X 2 FT. 6 IN. X 4 FT. 6 IN. STEEL PLATE (AASHTO M-111) SECTION A-A 1/2 IN. FLOWLINE (AS SHOWN ON PLANS) 6 IN. 2 FT. 0 IN. 4 FT. 6 IN. SLOPE PLATE TO MATCH SIDEWALK 6 IN. 4 FT. 0 IN. 6 IN. FL DETAIL FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 APPROVED: DATE: DRAWN BY: NBJ 12/12/00 D-10 METAL SIDEWALK CULVERT FOR VERT. CURB & GUTTER AND SIDEWALK DETAIL "A" PLAN VIEW A A B B x x x x x x x x x x x x x x x x x x x MIN. SECTION SECTION B-B SIZE BENDS TEE OR DEAD 11 1/4� 22 1/2� 45� 90� END 6" 8" 12" 1.0 1.5 3.0 1.5 2.5 4.5 2.5 4.5 9.0 4.5 8.0 16.5 3.5 5.5 12.0 MINIMUM BEARING SURFACE AREA (SQ. FT.) Bearing surface areas shown in chart are minimum. All fittings to be wrapped with polyethylene. Pipe installed under conditions different from those normally encountered shall require thrust blocks designed for those particular conditions. Thrust blocks on pipe larger than 16 inches diameter shall be designed for conditions existing at the installation site. Refer to Section 03300 for concrete requirements. 1. 2. 3. 4. 5. GENERAL NOTES: UNDISTURBED SOIL POLYETHYLENE BOND BREAKER UNDISTURBED SOIL BOND BREAKER POLYETHYLENE BEARING SURFACE POLYETHYLENE BOND BREAKER UNDISTURBED SOIL BEARING SURFACE SOIL UNDISTURBED BEARING SURFACE POLYETHYLENE BOND BREAKER BEDDING MATERIAL 2/3 DIA. TEE TYPICAL BEND TYPICAL CROSS-SECTION DEAD END BEARING SURFACES ARE A MINIMUM REQUIREMENT AND DO NOT RELIEVE DESIGN ENGINEER OF RESPONSIBILITY TO DESIGN EACH THRUST BLOCK. 16" 4.8 9.6 18.9 34.7 24.5 P.O. BOX 580, FORT COLLINS, CO. 80522 CITY OF FORT COLLINS UTILITIES WATER (970) FIELD 221-OPERATIONS 6700 TITLE OF DRAWING STANDARD CONCRETE THRUST BLOCKS REVISED DATE: DETAIL 01/16/04 2 BOTTOM OF PIPE AND A MINIMUM OF 12 INCHES ABOVE TOP OF PIPE. GRANULAR BEDDING MATERIAL SHALL BE A MINIMUM OF 4 INCHES BELOW INITIAL 12 IN. LIFT MIN. PIPE O.D. 4 IN. MIN. GRANULAR MATERIAL BEDDING ZONE NOTE: * INITIAL LIFT SHALL NOT EXCEED 2 FEET IN DEPTH. TRENCH WALL LOWER LIMIT OF SLOPING TRENCH IN WIDTH SECTION AS 02221 SPECIFIED * P.O. BOX 580, FORT COLLINS, CO. 80522 CITY OF FORT COLLINS UTILITIES WATER (970) FIELD 221-OPERATIONS 6700 REQUIREMENTS (DIP & PVC) WATER MAIN BEDDING TITLE OF DRAWING DETAIL REVISED DATE: 01/16/04 1 12" (Water & Sewer) If this section is less than 4' of existing asphalt/concrete, it must be removed and replaced. Edge of Pavement or Lip of Existing Gutter Compacted Lifts of Suitable Materials Pavement Thickness Varies Varies 1" (min.) (See Note 9 below for Storm.) 4" (min.) 6" (max.) Trench Width Varies 2' (min.) Bedding Material Undisturbed Soil Utility Conduit New Asphalt/Concrete Clean Road Base Existing Road Base 6" Full Depth Asphalt or X/Y Composite Section NOTES: 1. All trenches shall be backfilled in accordance with the above detail unless otherwise specified by the Local Entity Engineer. 2. Prior to placement of asphalt/concrete, pavement edge shall be saw cut to a clean, vertical, and straight edge. 3. Where the surrounding soils are non-expansive, a sand/cement slurry (1 sack mix) may be substituted for backfill material. 4. Trench width shall not be more than 16" nor less than 12" wider than the outside diameter of the pipe. 5. Use a #4 rebar at centers along the perimeter of concrete replacement sections. 6. Refer to Chapter 22, Materials & Construction Specifications for compaction and testing requirements. 7. In unimproved areas, all disturbed areas shall be regraded, seeded & mulched. 8. In concrete roadways, a minimum of one entire concrete panel must be replaced. 9. Bedding material depth when installing storm sewer shall be up to spring line, except in areas of unsuitable backfill; then, bedding material shall be placed to a level 12" above pipe. LARIMER COUNTY URBAN AREA STREET STANDARDS CONSTRUCTION DRAWINGS REVISION NO: 1 DRAWING 2201 DATE: 08/07/00 TRENCH DETAIL P.O. BOX 580, FORT COLLINS, CO. 80522 CITY OF FORT COLLINS UTILITIES WATER (970) FIELD 221-OPERATIONS 6700 TITLE OF DRAWING CP TEST AND LOCATOR STATION BOX REVISED DATE: DETAIL 04/11/05 25 CP TEST STATION W J E I U S A 7/16" 3 1/2" 7 5/16" 2" 5/8" 5 3/4" A S U I E J W STATION LOCATOR LID PLAN VIEW LID SECTION VIEW VALVE BOX SECTION VIEW 9" 6 1/8" 10" 7 9/16" 2 1/16" CLOSED PICKHOLE (TYPICAL OPPOSITE SIDE) 1/2" RAISED LETTERING (RECESSED FLUSH) REFERENCE SPECIFICATIONS 02622-2 THROUGH 02622-4 FOR LOCATOR FOR CP TEST STATION INFORMATION. REFERENCE SPECIFICATIONS 16640-5 STATION BOX INFORMATION. 1 1/8" P.O. BOX 580, FORT COLLINS, CO. 80522 CITY OF FORT COLLINS UTILITIES WATER (970) FIELD 221-OPERATIONS 6700 TITLE OF DRAWING TRACER WIRE DETAIL REVISED DATE: DETAIL 2/16/07 30 STREET STREET PVC WATER MAIN VALVE (TYPICAL) HYDRANT SECONDARY FIRE HYDRANT (TYPICAL) LOCATOR STATION PVC MAIN TRACER WIRE NOTES: 1. TRACER WIRE TO BE PLACED ALONG TOP CENTERLINE OF MAIN AND SECURED AS NECESSARY TO PREVENT MOVEMENT OF WIRE. TRACER WIRE SHALL BE SINGLE CONDUCTOR #12 STRANDED COPPER WITH TYPE THNN OR THWN FOR LOCATOR STATION DETAILS SEE DETAIL 25 2. 3. 4. 800' MAXIMUM DISTANCE BETWEEN LOCATOR STATIONS TRACER WIRES FOR PERPENDICULAR MAINS AT STREET INTERSECTIONS ARE NOT TO BE SPLICED TOGETHER. SEE NOTE 4 (TYPICAL) INSULATION DESIGNATED FOR DIRECT BURY. TRACER WIRE SHALL BE CONTINUOUS (WITHOUT SPLICES) WHENEVER POSSIBLE. WHEN SPLICES ARE REQUIRED, ALL SPLICES OF TRACER WIRE SHALL BE MADE USING BRASS SPLIT-BOLT CONNECTORS AND ROYSTON "MINI SPLICE-RIGHT" SPLICE KITS. PLAN VIEW 48" DIA. BEFORE BACKFILLING ARMOUR-FLEX TUBING AND GROUT KNOCKOUT BOX CURB FLOW 2' (MAX.) 1" DIA. IRON (TYP) PIPE BRACE MANHOLE RUNGS BELOW LID) METER (PLACED 12" O.C. 24" DIA. PRECAST CONCRETE MANHOLE 8" x 8" CONCRETE BLOCK (TYP.) AND REMOVABLE PLUG) WITH 1 27/32" DIA. HOLE YOKE BOX LID PART #YL-TP PART #YUC-7 WITH FORD AMR POD (FORD YOKE BOX %GENERAL NOTES: 1. LOCATION AND ALIGNMENT OF AMR POD ON PIT TOP CAN VARY. 2. SEE DETAIL 16-A FOR ADDITIONAL METER PIT INFORMATION. REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD SETTING FOR 1 1/2 IN. AND 2 IN. WATER METERS (PLAN VIEW) 16B 4/11/11 TYPE A GREASE INTERCEPTOR ����� ��� ���������� ������� 700 W��� S����� F��� C������, CO 80524 DETAIL 10 APPROVED: DATE: DRAWN BY: W 1.SECONDARY COMPARTMENT HAS VOLUME EQUAL TO APPROXIMATELY 1/3 OF THE TOTAL CAPACITY. 2.JOINT BETWEEN LID AND VAULT TO BE SEALED WITH 1 ROW 1-1/2" BUTYL MASTIC SEALANT PROVIDED BY C.P.C. 3.WALLS AND BOTTOM REINFORCED THROUGHOUT WITH 2x6/10 REMESH. {4.GREASE INTERCEPTOR MEETS ASTM C 1613 06 SPECIFICATIONS. 5.COVERS TO BE REINFORCED LONGITUDINALLY WITH NO.6 REBAR ON 6" CENTERS, NO.4 REBAR ON 6" CENTERS WIDTHWISE, AND NO.8 REBAR DIAGONALLY AROUND THE ACCESS HOLES. 6.PIPE WITHIN INTERCEPTOR AND CLEAN OUT SHALL BE SCHED. 40 MIN.} DESIGN PROPERTIES: CONCRETE STRENGTH: 4,000 PSI CONCRETE WEIGHT: 150 PCF STEEL STRENGTH: 60,000 PSI (GRADE 60) {PLAN VIEW} {SIDE VIEW} {WATER DEPTH} B A 24"� CAST IRON RING & COVER 3" THICK MIN BAFFLE WALL PIPE OUTSIDE DIAMETER +2" G 5" WALLS MIN. 10"W x 5"H BLOCKOUT IN BAFFLE WALL 8" LID 1" G {14"} CLEANOUT TO GRADE LONG SWEEP WYE, SCHEDULE 40 MATERIAL {12"} {D} {12"} {2"} {9"} {C} {8"} {12"} VENT PIPING WITH VTR OR INTERNAL TANK VENT. VENT THRU ROOF OF BUILDING MT 5-13-2010 RH WATER CAPACITY APPROX. GALLONS GREASE CAPACITY APPROX. CUBIC FT. DIMENSIONS TWO COMPARTMENT TANK INCHES 500 NOTES: 4' A 7' B 31" C 33" D 31" E 5' F 26" G 750 4' 7' 46" 56" 44" 6' 26" 1000 6' 10' 31" 33" 31" 57" 38" 1250 6' 10' 36" 38" 36" 63" 38" 1500 2000 2500 6' 13' 33" 35" 33" 63" 50" 6' 13' 44" 46" 44" 69" 50" 6' 12' 58" 60" 58" 87" 48" MAY TRANSITION TO SER-35 PIPE DOWN STREAM OF CLEANOUT. 166 250 333 416 500 666 833 ALTERNATE BASE POURED INVERT PRECAST MANHOLE BASE 2 IN. MIN. SLOPE 1 IN. MIN. 8 IN. MIN. 6 IN. 15 IN. OR LESS 48 IN. 18 IN. TO 30 IN. 60 IN. OVER 30 INCHES 72 IN. MIN. MANHOLE MINIMUM INSIDE DIAMETER OF DIAMETER MANHOLE SHALL BE AS FOLLOWS: PIPE SIZE 5 FT. MIN. DEPTH CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE ASTM C-478 ECCENTRIC CONE PRE-FORMED PLASTIC GASKET ASTM C-478 MANHOLE SECTIONS GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET CAST-IN-PLACE CONCRETE BASE 16 IN. MAX. FINISHED GRADE 30 IN. MIN. 48 IN. MAX. VARIABLE 28 IN. MAX. 24 IN. SEE TABLE 6 IN. 12 IN. SLOPE 1 IN./FT. 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. 8 IN. MIN DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL STANDARD MANHOLE WW-3 NBJ 4/11/11 12" ROLL-OVER VERTICAL (LOVELAND) Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) DATE: 03/01/02 CURB AND GUTTER (MELDRUM ST.) URBAN AREA STREET STANDARDS LARIMER COUNTY CONSTRUCTION DRAWINGS REVISION NO: 1 701 DRAWING Sidewalk Driveway LIP F.L. T.C. DRIVEWAY SIDEWALK SECTION A-A NOTE: 1. Sidewalk grade shall remain consistent across driveway 3. This detail applies to Residential & Commercial driveways. 6" 6" Residential Detached Sidewalk Attached Sidewalk 1/2" Expansion Joint Material 1/2" Expansion Joint Material A A 2. For driveway design requirements, see CONST. DWG. 706 & 707. DETACHED ATTACHED 3'-0" 6'-0" All Sidewalk Thickness Shall Be 6" minimum. Min. STANDARD SIDEWALK STREET STANDARDS LARIMER URBAN AREA COUNTY REVISION NO: 1 CONSTRUCTION DRAWINGS DATE: 04/01/07 1601 DRAWING SIDEWALK 8" Commercial ATTACHED SIDEWALK DETAIL Slope sidewalk to curb 1/4" per foot. NOTE: Construct sidewalk with joints at 10' intervals R 1/8" WEAKENED PLANE JOINT EXPANSION JOINT R1/4" and aligned with scoring on curb. INSTALL IN LOCATIONS SPECIFIED IN CHAPTER 22 1/2" 1/4" 1/4 SLAB THICKNESS 1/4" 1/2" Expansion Joint material DETACHED SIDEWALK DETAIL Variable Landscaping Slope sidewalk to curb 1/4" per foot. 2' min. Slope: Minumum 1 4"/ft Maximum 3"/ft CONSTRUCTION SIDEWALK DETAIL LARIMER COUNTY STREET URBAN STANDARDS AREA DRAWINGS 1602 DRAWING REVISION DATE: 04/NO: 01/07 2 1. NO JOINTS ARE ALLOWED IN THE FLOWLINE. SIX INCH WIDE CURB OR "DUMMY JOINT" MAY BE TOOLED NO CLOSER THAN 6 INCHES FROM FLOW LINE AS SHOWN. 2. MINIMUM CONCRETE THICKNESS IS 6 INCHES. 3. JOINT PATTERN TO BE ACCORDING TO 'INTERSECTION GUTTER DETAIL' OR AS DETERMINED BY THE LOCAL ENTITY. 4. WOOD FLOAT FINISH IS REQUIRED OVER THE SLOPED SURFACE OF RAMP AND FLARES. 5. A 6 INCH WIDE CURB MAY BE POURED AT THE BACK OF THE RAMP AS SHOWN IF REQUIRED. IF CURB IS USED IT SHALL MATCH THE CURB AND GUTTER STYLE OF ADJACENT CURB AND GUTTER. 6. MINIMUM RAMP WIDTH SHALL BE FOUR FEET, OR THE SAME AS THE WIDEST ADJACENT SIDEWALK, WHICHEVER IS GREATER, UP TO A MAXIMUM WIDTH OF 8 FEET. 7. THE RAMP LANDING MAY BE POURED MONOLITHIC WITH THE ADJACENT TRANSITIONS PROVIDED THAT AN APPROVED "SHAKE-ON" PIGMENT BE USED TO COLOR THE LANDING AREA. 8. T= THICKNESS (AS SPECIFIED ON PLANS OR LOCAL ENTITY ENGINEER). STANDARD GRAY CONCRETE RAMP WITH PARTIALLY COLORED CONCRETE SECTION A-A LIP OF GUTTER PLAN VIEW FLOWLINE CURB A A 0.5' TYP. N.T.S. 6" 1:12 SLOPE MAX. CURB 0.5' 4' MIN. N.T.S. FLARE OPTION CURB OPTION 6" CURB 0" CURB 1' R 2' NOTES: t=6" or as specified 1"/ft. Max 1"/ft. Max 1.5' TRANSITION 1.5' TRANSITION Flared Option 2' FL REVISION NO: 1 DATE: 04/01/07 DRAWING STREET STANDARDS DRAWINGS 1606 URBAN AREA LARIMER COUNTY PEDESTRIAN RAMP DETAIL (For New Const. & Alterations) CONSTRUCTION 1:25 slope (max.) Truncated Dome Warning Detection Truncated Dome Warning Detection Curb Flare Varies Curb 2'-0" Flare Ramp concrete ramps Panels embedded in the Apron Gutter or Curb and Gutter Flow line 1:20 Slope 1:12 MAX Slope Section A-A NTS Varies Varies Curb Curb Flare Ramp 2'-0" Varies Panels Panels 6" A A CL Pedestrian flow Aligned with Ramp Width: 4.5' 5.0' 6.0' 7.0' 8.0' Note: Truncated dome panels are available in 2'x2' squares and 2'x2.5' rectangles. Combine the widths to fit the ramp. Panels may be cut to no less than a 2'x1.5' size. Panel Width Combinations: 2'+2.5' 2.5'+2.5' 2'+2'+2' 2.5'+2'+2.5' 2'+2'+2'+2' Note: 1. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. The panel material shall be "Cast In Tact Warning Panels" or an equivalent material that must be first approved by the City Engineer prior to installation. The panel color shall be red, no other color is approved. Specifications for the panel and installation instructions will be provided upon request. 2. This drawing shows vertical curb. For Drive Over Curb the warning detection location shall be placed in the same position 6" back from the Face of Curb or . Case 1-Directional Ramps Case 2-Non-Directional Ramps Varies Panels Ramp Panels Flare 2'-0" Curb Case 3-Mid-Block Ramps 6" Panels Panels Apron Gutter or Flare 6" Flare (Center line of ramp) CL -Center line of ramp BOC BOC BOC FOC FL or F FOC BOC FL -Back of Curb -Face of Curb -Flow line 2' REVISION NO: DATE: 04/01/07 DRAWING STREET STANDARDS DRAWINGS 1607 URBAN AREA LARIMER COUNTY TRUNCATED DOME WARNING FOR ACCESS RAMPS CONSTRUCTION FORT COLLINS ONLY City UTILITY of Fort PLAN Collins, APPROVAL Colorado Date Date Date Date Date Date APPROVED: City Engineer Traffic Engineer Parks & Recreation Stormwater Utility Water & Wastewater Utility CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: 1:12 max. X=2' min. Driveway Width Varies 2'-0" 6" Attached Sidewalk Lip FL Back of curb Right of Way line Detached Attached Right of Way Line Detached Sidewalk 1:24 (max.) NOTE: 1. Concrete driveway must be provided to the property line. Refer to C������ 25for minimum removal dimensions. X Y W X Y W = Width 1:12 (max.) Property Line t 1/4" PER FT. N.T.S. SECTION A-A 2" t 1:12 (max.) t X = Curb Transition Length Y = Parkway Width in Type I Approach W = Driveway Width (See Drawing 707) t = Concrete Thickness - minimum 6" Type I = With Detached Sidewalk Type II = With Attached Sidewalk TYPE I TYPE II 1:12 (max.) 1:48 A A PERSPECTIVE X=6'-0" 1:48 SLOPE 1:12 max. B B WALK Y t t WALK t 2" FLOWLINE JOINT EXPANSION BOW 1:12 (max.) 1:24 SECTION B-B N.T.S. LARIMER COUNTY DRAWINGS CONSTRUCTION REVISION NO: 2 706 DRAWING STREET STANDARDS URBAN AREA DATE: 04/01/07 STANDARD DRIVEWAY APPROACH (TYPES I & II) Ramp if necessary 1:12 max. BOW Expansion joint if drive continues as concrete WALK 6" (max.) 1/2" 2"R. NOT TO SCALE 3 DT1 CONCRETE DETAILS BARRIER CURB 6" 10" MIN. 6" FL 1 1/4" TYPICAL INFLOW VERTICAL CURB FLOW FLOW 1' CURB CHASE DETAIL NTS * SEE SHEET ? FOR WIDTH OF CURB OPENING * VARIES NEW ASPHALT SURFACE NEW BASE AGGREGATE COURSE 12" EXISTING ASPHALT SURFACE EXISTING AGGREGATE NOTE: BASE THE EXISTING ASPHALT SURFACE SHALL BE SAW-CUT AND REMOVED FROM THE EXISTING AGGREGATE BASE TO A LINE ONE FOOT FROM AND PARALLEL TO THE EDGE OF EXISTING PAVEMENT. THE ASPHALT SURFACE SHALL BE SAWED TO FORM A PERPENDICULAR CLEAN JOINT AND A COATING OF BITUMINOUS MATERIALS (PRIME COAT) SHALL BE APPLIED TO THE JOINT PRIOR TO THE PROPOSED SURFACING OPERATION. ASPHALT PAVEMENT JOINT DETAIL N.T.S. STREETS\ASPHDET 2 1' CURB OPENING DETAIL DT1 1 DT1 6" 1" 7" 12" 6" 2" RAD. 1" RAD. 6" C4.00 FLOODPLAIN EXHIBIT C. Snowdon C. Snowdon 1" = 20' EXISTING CITY FLOODWAY NOTES: 1.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 2.ALL ELEVATIONS DEPICTED IN PLAN VIEW AND BENCHMARKS LISTED HEREON ARE PER THE CITY OF FORT COLLINS VERTICAL CONTROL DATUM (NGVD 29 - UNADJUSTED). 3.A FLOODPLAIN USE PERMIT SHALL BE REQUIRED FOR EACH STRUCTURE AND EACH SITE CONSTRUCTION ELEMENT (DETENTION PONDS, BIKE PATHS, PARKING LOT, UTILITIES, ETC.) IN THE FLOODPLAIN. 4.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT. LANDSCAPING SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE FLOODWAY. {5.REFER TO THE "DRAINAGE LETTER FOR CANYON PLACE" BY NORTHERN ENGINEERING, DATED DECEMBER 26, 2012 FOR ADDITIONAL INFORMATION. 6.A NO RISE CERTIFICATION IS REQUIRED FOR ANY WORK WITHIN THE FLOODWAY. 7.ALL HVAC EQUIPMENT IS TO BE LOCATED ON THE ROOFTOP OF THE STRUCTURE. 8.ALL STRUCTURES WITHIN THE FLOODWAY (PICNIC TABLES, BIKE RACKS, ETC.) SHALL BE ANCHORED.} FIELD SURVEY BY: BENCHMARKS: Northern Engineering Service, Inc. Project No. 838-002 Date: June 11, 2012 BENCHMARK #1: City of Fort Collins Benchmark 6-00 Elevation= 4990.68 (NGVD 29 - Unadjusted) BENCHMARK #2: City of Fort Collins Benchmark 1-11 Elevation= 5005.44 (NGVD 29 - Unadjusted) CROSS-SECTION (CSL) BASE FLOOD ELEVATION (BFE) ELEVATION NGVD 29 (UNADJUSTED) 5000 20554 NORTH ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 60 90 GRAPHIC SCALE: LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR EXISTING STORM SEWER LINE W/ MH ST � PROPERTY BOUNDARY EXISTING INLET GRATE LIMITS OF 100-YR FLOOD FRINGE / / / / / / / / / / / / / / / / / / / / / / / / / / / / PROPOSED UNDERDRAIN UD PROPOSED STORM DRAIN PROPOSED CURB & GUTTER EXISTING CURB & GUTTER FOR STORMWATER REVIEW ONLY NOT FOR CONSTRUCTION CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO K��� ����'� �����. C��� ������ ��� ���. R City UTILITY of Fort PLAN Collins, APPROVAL Colorado Date Date Date Date Date Date APPROVED: City Engineer Traffic Engineer Parks & Recreation Stormwater Utility Water & Wastewater Utility CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CANYON AVENUE (100' RIGHT-OF-WAY) W. MAGNOLIA STREET (100' RIGHT-OF-WAY) S. MELDRUM STREET (100' RIGHT-OF-WAY) EXISTING BANK BUILDING PROPOSED OFFICE BUILDING FFE=98.6 FFE=98.60 RAMP RAMP LANDING LANDING FFE=98.60 FFE=98.60 LANDING RAMP LANDING LANDING No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� 20 5020 PROPERTY BOUNDARY PROPOSED CONTOUR EXISTING CONTOUR LEGEND: PROPOSED VERTICAL CURB AND GUTTER (TYPICAL) EXISTING CURB AND GUTTER EXISTING GROUND ELEVATION 74.86 PROPOSED OVERLAND FLOW DIRECTION PROPOSED FINISHED GRADE ELEVATION GRAPHIC SCALE: PROPOSED SAWCUT LINE PROPOSED PROPERTY LINE C3.00 GRADING PLAN C. Snowdon C. Snowdon 1" = 20' (75.41) FLOODPLAIN FLOODWAY / / / / / / / / / / / / / / / / / / / / / / / / / ( IN FEET ) 1 inch = ft. XX 0 XX Feet XX XX XX NORTH PROPOSED CONCENTRATED FLOW DIRECTION CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO K��� ����'� �����. C��� ������ ��� ���. R NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.A FLOODPLAIN USE PERMIT IS REQUIRED PRIOR TO ANY CONSTRUCTION WITHIN THE FLOODPLAIN. SEE SHEET C4.00 FOR FLOOD INFORMATION. 6.A NO-RISE CERTIFICATION IS REQUIRED PRIOR TO ANY CONSTRUCTION WITHIN THE FLOODWAY. SEE SHEET C4.00 FOR FLOOD INFORMATION. City UTILITY of Fort PLAN Collins, APPROVAL Colorado Date Date Date Date Date Date APPROVED: City Engineer Traffic Engineer Parks & Recreation Stormwater Utility Water & Wastewater Utility CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: DETAIL GRADING A DETAIL GRADING B E E E VAULT ELEC CONTROL IRR CONTROL IRR VAULT F.O. E E E E E E E E E G G G FO FO FO FO FO G G G G G G G G G G G G G G G G G G G G G ST ST W W W ST ST SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST SS SS W F C.O. GM E EM G G G G G S E E E E E E E E E E 12' APPROXIMATE ASPHALT PATCHING LIMITS (SEE NOTE 5) PROPERTY BOUNDARY LOT 2 LOT 1 EXISTING BANK (319 S. MELDRUM STREET) EXISTING OFFICE BUILDING (318 CANYON AVENUE) PROPOSED BUILDING CANYON AVENUE (100' RIGHT-OF-WAY) S. MELDRUM STREET (100' RIGHT-OF-WAY) W. MAGNOLIA STREET (100' RIGHT-OF-WAY) 26' APPROXIMATE ASPHALT PATCHING LIMITS (SEE NOTE 5) G G G G G 10' APPROXIMATE ASPHALT PATCHING LIMITS (SEE NOTE 5) EXISTING 5' WALK PROPOSED 5' WALK ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO K��� ����'� �����. C��� ������ ��� ���. R C2.00 UTILITY PLAN C. Snowdon C. Snowdon 1" = 20' NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER & SANITARY SEWER CONSTRUCTION SHALL BE PER THE FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3.MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 4.5'. MAXIMUM COVER SHALL BE 5.5'. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6.PROPOSED 6" FIRE LINE TO BE INSTALLED WITH TRACER WIRE PER FORT COLLINS STANDARD DETAIL 30. 7.ALL EXISTING SANITARY SEWER SERVICE ARE APPROXIMATE AND TO BE FIELD VERIFIED AND ABANDONED. ALL SEWER SERVICES TO BE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES BY CONTACTING (970) 221-6700. 8.A FLOODPLAIN USE PERMIT IS REQUIRED PRIOR TO ANY CONSTRUCTION WITHIN THE FLOODPLAIN. SEE SHEET C4.00 FOR FLOOD INFORMATION. 9.A NO-RISE CERTIFICATION IS REQUIRED PRIOR TO ANY CONSTRUCTION WITHIN THE FLOODWAY. SEE SHEET C4.00 FOR FLOOD INFORMATION. City UTILITY of Fort PLAN Collins, APPROVAL Colorado Date Date Date Date Date Date APPROVED: City Engineer Traffic Engineer Parks & Recreation Stormwater Utility Water & Wastewater Utility CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: NORTH PROPOSED FIRE SERVICE PROPOSED SANITARY SEWER SERVICE PROPOSED DOMESTIC WATER SERVICE EXISTING WATER MAIN WITH VALVE GRAPHIC SCALE: GRAPHIC SCALE: W S FW EXISTING RIGHT-OF-WAY PROPOSED CURB AND GUTTER No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� SS EXISTING SEWER MAIN WITH MANHOLE WV S EXISTING EDGE OF ASPHALT EXISTING CURB & GUTTER SS EXISTING SANITARY SEWER LINE E EXISTING ELECTRIC W EXISTING WATER LINE T EXISTING TELEPHONE G EXISTING GAS FO EXISTING FIBER OPTICS VAULT ELEC ELECTRICAL VAULT WV WATER VALVE CONTROL IRR IRRIGATION CONTROL VALVE LIGHT POLE � ELECTRICAL METER � GAS METER CABLE VAULT F.O. FIBER-OPTIC BOX T TELEPHONE PEDESTAL ELEC BRKR � WATER METER LIGHT POLE INLET GRATE IRRIGATION BACKFLOW PREVENTER VAULT CABLE BREAKER BOX *NOTE: EVERYTHING SHOWN IN LEGEND MAY NOT APPEAR IN PLAN SET. E E E E E E E E E E E E E E E E E E E E E E E E E E VAULT ELEC � � � � WV � CONTROL IRR CONTROL IRR VAULT F.O. E E E E E E E E E G G G G FO FO FO FO FO G G G G G G G G G G G G G G G G G G G G G G ST ST W W W ST ST ST ST ST ST SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST SS SS / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CANYON AVENUE (100' RIGHT-OF-WAY) W. MAGNOLIA STREET (100' RIGHT-OF-WAY) S. MELDRUM STREET (100' RIGHT-OF-WAY) EXISTING BANK BUILDING TO REMAIN (319 S. MELDRUM STREET) EXISTING OFFICE BUILDING (SEE ARCHITECTURAL PLANS FOR BUILDING AND SURROUNDING LANDSCAPE STRUCTURE DEMOLITION) EXISTING ROW 4' SIDEWALK TO REMAIN ASPHALT (TO BE REMOVED) EXISTING OFFICE BUILDING TO REMAIN (318 CANYON AVENUE) No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C1.00 AND DEMOLITION PLAN EXISTING CONDITIONS D. Fry C. Snowdon 1" = 20' VAULT ELEC ELECTRICAL VAULT WV WATER VALVE CONTROL IRR IRRIGATION CONTROL VALVE LIGHT POLE � ELECTRICAL METER � GAS METER TREES CABLE VAULT F.O. FIBER-OPTIC BOX EDGE OF ASPHALT CURB & GUTTER MAJOR CONTOUR SS SANITARY SEWER LINE W WATER LINE SIGN ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 NORTH LEGEND: GRAPHIC SCALE: T TELEPHONE PEDESTAL 5001 MINOR CONTOUR 5000 EXISTING CONCRETE TO BE REMOVED ELEC BRKR � WATER METER LIGHT POLE POST INLET GRATE IRRIGATION BACKFLOW PREVENTER VAULT CABLE BREAKER BOX CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO K��� ����'� �����. C��� ������ ��� ���. R City UTILITY of Fort PLAN Collins, APPROVAL Colorado Date Date Date Date Date Date APPROVED: City Engineer Traffic Engineer Parks & Recreation Stormwater Utility Water & Wastewater Utility CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: E ELECTRIC FO FIBER OPTICS G GAS T TELEPHONE NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. {THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249.} 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7.A FLOODPLAIN USE PERMIT AND NO-RISE CERTIFICATION IS REQUIRED PRIOR TO ANY CONSTRUCTION WITHIN THE FLOODWAY. SEE SHEET C4.00 FOR FLOOD INFORMATION. RIGHT-OF-WAY LINE LOTS 1-12 BLOCK 93 PLAT OF CITY OF FORT COLLINS SOUTH MELDRUM STREET (100' ROW) (PER PLAT OF CITY OF FORT COLLINS) CANYON AVENUE (100' ROW) (PER PLAT OF CITY OF FORT COLLINS) WEST MAGNOLIA STREET (100' ROW) (PER PLAT OF CITY OF FORT COLLINS) ORIGINAL LOT LINES & PROPERTY LINES TO BE VACATED BY THIS PLAT ORIGINAL LOT LINES & PROPERTY LINES TO BE VACATED BY THIS PLAT NEW LOT LINES TO BE CREATED BY THIS PLAT SOUTH LINE OF LOT 1, BLOCK 83 BASIS OF BEARINGS BLOCK 83 FND #4 REBAR w/ 1" PLASTIC CAP LS 34174 FND #4 REBAR w/ 1" PLASTIC CAP LS 4502 FND 1" SQUARE IRON ROD INGRESS/EGRESS EASEMENT BOOK 1970, PAGE 460 TO BE VACATED BY THIS PLAT 272.71' S44�40'41"E 47.64' 20.08' 3.01' N.T.S. CITY FLOOD FRINGE LINE CITY FLOODWAY LINE CITY FLOOD FRINGE LINE CITY FLOODWAY LINE N45�17'38"E 465.58' HIGH RISK AREA FLOODWAY AREA 8.83' 18.34' S44�40'41"E 17.70' S89�44'37"E 50.50' UTILITY EASEMENT N44�40'41"W 43.08' 16.33' UTILITY EASEMENT BLOCK 84 PLAT OF CITY OF FORT COLLINS REVIEWED BY: G. Gilliland CLIENT: DRAWN BY: SCALE: DATE: 12/26/12 PROJECT: 838-002 Sheet Of 2 Sheets CANYON PLACE CANYON PLACE CANYON PLACE NOTICE : According to Colorado law you must commence any legal action based upon any defect in this survey within three years after you discover such defect. In no event may any action based upon any defect in this survey be commenced more than ten years after the date of the certificate shown hereon. RANGE: TOWNSHIP: SECTION: 200 S���� C������ A�����, S���� 10 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� 2 SECTION 11, T7N, R69W CITY OF FORT COLLINS, COLORADO Blue Ocean L. Smith 1" = 20' 11 7N 69 W of the 6th PM NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 (US SURVEY FEET) LEGEND BOUNDARY LINE CENTERLINE EASEMENT LINE LOT LINE FOUND CORNER AS DESCRIBED RIGHT-OF-WAY CANYON PLACE LOTS 1, 2 AND 3, BLOCK 83, CITY OF FORT COLLINS, LOCATED IN THE SOUTHEAST QUARTER OF SECTION 11, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO connection with the Development which is the subject of this Plat. This warranty and guarantee is made in accordance with the City Land Use Code and/or the Transitional Land Use Regulations, as applicable. This guarantee applies to the streets and all other appurtenant structures and amenities lying within the rights-of-way, Easements and other public properties, including, without limitation, all curbing, sidewalks, bike paths, drainage pipes, culverts, catch basins, drainage ditches and landscaping. Any maintenance and/or repair required on utilities shall be coordinated with the owning utility company or department. The Owner shall maintain said improvements in a manner that will assure compliance on a consistent basis with all construction standards, safety requirements and environmental protection requirements of the City. The Owner shall also correct and repair, or cause to be corrected and repaired, all damages to said improvements resulting from development-related or building-related activities. In the event the Owner fails to correct any damages within thirty (30) days after written notice thereof, then said damages may be corrected by the City and all costs and charges billed to and paid by the Owner. The City shall also have any other remedies available to it as authorized by law. Any damages which occurred prior to the end of said two (2) year period and which are unrepaired at the termination of said period shall remain the responsibility of the Owner. REPAIR GUARANTEE: In consideration of the approval of this final Plat and other valuable consideration, the Owner does hereby agree to hold the City harmless for a five (5) year period, commencing upon the date of completion and first acceptance by the City of the improvements to be constructed in connection with the development which is the subject of this Plat, from any and all claims, damages, or demands arising on account of the design and construction of public improvements of the property shown herein; and the Owner furthermore commits to make necessary repairs to said public improvements, to include, without limitation, the roads, streets, fills, embankments, ditches, cross pans, sub-drains, culverts, walls and bridges within the right-of-way, Easements and other public properties, resulting from failures caused by design and/or construction defects. This agreement to hold the City harmless includes defects in materials and workmanship, as well as defects caused by or consisting of settling trenches, fills or excavations. Further, the Owner warrants that he/she owns fee simple title to the property shown hereon and agrees that the City shall not be liable to the Owner or his/her successors in interest during the warranty period, for any claim of damages resulting from negligence in exercising engineering techniques and due caution in the construction of cross drains, drives, structures or buildings, the changing of courses of streams and rivers, flooding from natural creeks and rivers, and any other matter whatsoever on private property. Any and all monetary liability occurring under this paragraph shall be the liability of the Owner. I further warrant that I have the right to convey said land according to this Plat. NOTICE OF OTHER DOCUMENTS: All persons take notice that the Owner has executed certain documents pertaining to this Development which create certain rights and obligations of the Development, the Owner and/or subsequent Owners of all or portions of the Development site, many of which obligations constitute promises and covenants that, along with the obligations under this Plat, run with the land. The said documents may also be amended from time to time and may include, without limitation, the Development Agreement, Site And Landscape Covenants, Final Site Plan, Final Landscape Plan, and Architectural Elevations, which documents are on file in the office of the clerk of the City and should be closely examined by all persons interested in purchasing any portion of the Development site. SURVEYOR'S STATEMENT I, Gerald D. Gilliland, a Colorado Registered Professional Land Surveyor do hereby state that this Subdivision Plat was prepared from an actual survey under my personal supervision, that the monumentation as indicated hereon were found or set as shown, and that the foregoing plat is an accurate representation thereof, all this to the best of my knowledge, information and belief. __________________________________ Gerald D. Gilliland Colorado Registered Professional Land Surveyor No. 14823 CERTIFICATE OF DEDICATION: The Owner does hereby dedicate and convey to the City of Fort Collins, Colorado (hereafter “City”), for public use, forever, a permanent right-of-way for street purposes and the “Easements” as laid out and designated on this Plat; provided, however, that (1) acceptance by the City of this dedication of Easements does not impose upon the City a duty to maintain the Easements so dedicated, and (2) acceptance by the City of this dedication of streets does not impose upon the City a duty to maintain streets so dedicated until such time as the provisions of the Maintenance Guarantee have been fully satisfied. The streets dedicated on this Plat are the fee property of the City as provided in Section 31-23-107 C.R.S. The City's rights under the Easements include the right to install, operate, access, maintain, repair, reconstruct, remove and replace within the Easements public improvements consistent with the intended purpose of the Easements; the right to install, maintain and use gates in any fences that cross the Easements; the right to mark the location of the Easements with suitable markers; and the right to permit other public utilities to exercise these same rights. Owner reserves the right to use the Easements for purposes that do not interfere with the full enjoyment of the rights hereby granted. The City is responsible for maintenance of its own improvements and for repairing any damage caused by its activities in the Easements, but by acceptance of this dedication, the City does not accept the duty of maintenance of the Easements, or of improvements in the Easements that are not owned by the City. Owner will maintain the surface of the Easements in a sanitary condition in compliance with any applicable weed, nuisance or other legal requirements. Except as expressly permitted in an approved plan of development or other written agreement with the City, Owner will not install on the Easements, or permit the installation on the Easements, of any building, structure, improvement, fence, retaining wall, sidewalk, tree or other landscaping (other than usual and customary grasses and other ground cover). In the event such obstacles are installed in the Easements, the City has the right to require the Owner to remove such obstacles from the Easements. If Owner does not remove such obstacles, the City may remove such obstacles without any liability or obligation for repair and replacement thereof, and charge the Owner the City's costs for such removal. If the City chooses not to remove the obstacles, the City will not be liable for any damage to the obstacles or any other property to which they are attached. The rights granted to the City by this Plat inure to the benefit of the City's agents, licensees, permittees and assigns. ATTORNEY'S CERTIFICATION I hereby certify that this Subdivision Plat has been duly executed as required pursuant to Section 2.2.3(C)(3)(a) through (e) inclusive of the Land Use Code of the City of Fort Collins and that all persons signing this Subdivision Plat on behalf of a corporation or other entity are duly authorized signatories under the laws of the State of Colorado. This Certification is based upon the records of the Clerk and Recorder of Larimer County, Colorado as of the date of execution of the Plat and other information discovered by me through reasonable inquiry and is limited as authorized by Section 2.2.3(C)(3)(f) of the Land Use Code. Attorney:________________________________________ Address: ________________________________________ ________________________________________ Registration No.:__________________________________ NOTICE ALL RESPONSIBILITIES AND COSTS OF OPERATION, MAINTENANCE AND RECONSTRUCTION OF THE PRIVATE STREETS AND/OR DRIVES LOCATED ON THE PRIVATE PROPERTY THAT IS THE SUBJECT OF THIS PLAT SHALL BE BORNE BY THE OWNERS OF SAID PROPERTY, EITHER INDIVIDUALLY, OR COLLECTIVELY, THROUGH A PROPERTY OWNERS' ASSOCIATION, IF APPLICABLE. THE CITY OF FORT COLLINS SHALL HAVE NO OBLIGATION OF OPERATION, MAINTENANCE OR RECONSTRUCTION OF SUCH PRIVATE STREETS AND/OR DRIVES NOR SHALL THE CITY HAVE ANY OBLIGATION TO ACCEPT SUCH STREETS AND/OR DRIVES AS PUBLIC STREETS OR DRIVES. APPROVED AS TO FORM, CITY ENGINEER By the City Engineer of the City of Fort Collins, Colorado this ______day of _____________ A.D., 20_____. ____________________________________________________ City Engineer PLANNING APPROVAL By the Director of Planning the City of Fort Collins, Colorado this _____ day of ___________ A.D., 20_____. _____________________________________________________ Director of Community Development and Neighborhood Services NOTES: 1) The Basis of Bearings is the South line of Lot 1, Block 83, City of Fort Collins bearing North 89°42'48" West (assumed bearing). 2) All information regarding easements, right-of-way or title of record, Northern Engineering relied upon Title Commitment 01330-14179 prepared by Stewart Title Guaranty Company, dated September 25, 2012. 3) Ingress/Egress Easement per Book 1970, Page 460 to be vacated by this plat. 4) All areas within the Lot 1 and Lot 2 located outside of the 100-year flood fringe are located within the City of Fort Collins Moderate Risk Floodplain. OWNER:Blue Ocean Enterprises, Inc. BY:_________________________________ Steve Schroyer STATE OF COLORADO ) )SS COUNTY OF LARIMER ) The foregoing instrument was acknowledged before me this _____ day of ___________________, 20____, by Steve Schroyer. Witness my hand and official seal My commission expires: ________________ _______________________________ Notary Public OWNER:Norlarco Credit Union BY: _________________________________ TITLE: ______________________________ STATE OF COLORADO ) )SS COUNTY OF LARIMER ) The foregoing instrument was acknowledged before me this _____ day of ___________________, 20____, by _____________________________________________, as ____________________________________ of Norlarco Credit Union. Witness my hand and official seal My commission expires: ________________ _______________________________ Notary Public STATEMENT OF OWNERSHIP AND SUBDIVISION: Know all persons by these presents, that the undersigned owner(s) of the following described land: Lots 1, 2, and 3, Block 83, City of Fort Collins, located in the Southeast Quarter of Section 11, Township 7 North, Range 69 West of the 6th P.M., City of Fort Collins, County of Larimer, State of Colorado, contains 54,225 square feet or 1.245 acres. For themselves and their successors in interest (collectively "Owner") have caused the above described land to be surveyed and subdivided into lots, tracts and streets as shown on this Plat to be known as CANYON PLACE (the "Development"), subject to all easements and rights-of-way now of record or existing or indicated on this Plat. The rights and obligations of this Plat shall run with the land. CANYON PLACE LOTS 1, 2 AND 3, BLOCK 83, CITY OF FORT COLLINS, LOCATED IN THE SOUTHEAST QUARTER OF SECTION 11, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO 1 SECTION 11, T7N, R69W CITY OF FORT COLLINS, COLORADO N.A. L. Smith N.A. 11 7N 69 W of the 6th PM VICINITY MAP VICINITY MAP {SCALE 1" = 1000'} 9' 17' EXISTING 4' SIDEWALK EXISTING OFFICE BUILDING (318 CANYON AVENUE) PROPOSED BUILDING CANYON AVENUE (100' RIGHT-OF-WAY) S. MELDRUM STREET (100' RIGHT-OF-WAY) W. MAGNOLIA STREET (100' RIGHT-OF-WAY) PATIO EXISTING 5' SIDEWALK PROPOSED 5' SIDEWALK LINE TABLE LINE L1 L2 L3 L4 L5 L6 L7 LENGTH 10.14' 67.12' 24.00' 26.11' 12.49' 12.82' 18.00' BEARING N00�09'38.75"E N44�32'58.18"W N45�23'21.71"E S44�32'58.18"E S44�32'58.18"E N44�41'18.76"W N45�24'42.69"E Curve Table CURVE C1 C2 DELTA 44�42'37" 184�08'02" RADIUS 5.00' 4.67' LENGTH 3.90' 15.00' BEARING N22�11'40"W N47�22'42"E CHORD 3.80' 9.33' N45�19'19"E N89�42'48"W (BASIS OF BEARING) S00�15'07"W 20' TRASH EXISTING 5' SIDEWALK 5' NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 GRAPHIC SCALE: LEGEND: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO K��� ����'� �����. C��� ������ ��� ���. R PROPOSED SWALE 1.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 2.EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS\TRAILS AT MAXIMUM SPACING OF 50 FEET. 3.SEE LANDSCAPE PLAN BY LANDWORKS DESIGN, INC FOR ALL DECORATIVE CONCRETE DESIGN INFORMATION AND SPECIFICATIONS. 4.SEE THE PLAT BY NORTHERN ENGINEERING FOR ALL EASEMENTS AND LOT INFORMATION. 5.ALL STRIPING ALONG MAGNOLIA SHALL BE REMOVED & REPLACED PER CITY OF FORT COLLINS STANDARDS. 6.SEE CDOT STANDARD M-412-1 FOR ALL CONCRETE PAVING JOINT INFORMATION. 7.ALL REMOVED OR DAMAGED SIDEWALKS SHALL BE REPLACE WITH A 5' WIDE SECTION PER CITY OF FORT COLLINS STANDARDS. NOTES: HEAVY DUTY PAVING BENCHMARK/BASIS OF BEARING PROPERTY BOUNDARY LIMITS OF 100-YR FLOODWAY PROPOSED BARRIER CURB Date Date Date Date Date Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Water & Wastewater Utility Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner City of Fort Collins, Colorado UTILITY PLAN APPROVAL No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� HC1 HORIZONTAL CONTROL PLAN C. Snowdon C. Snowdon 1" = 20' BENCHMARK #1: City of Fort Collins Benchmark 6-00 Located on a catch basin at the northwest corner of Mulberry Street and College Avenue. Elevation = 4990.68 (NGVD 29 - Unadjusted) BENCHMARK #2: City of Fort Collins Benchmark 1-11 Located on the Southeast corner of Mulberry Street and Loomis Avenue, at the northeast corner of a concrete traffic signal base. Elevation = 5005.44 (NGVD 29 - Unadjusted) Basis of Bearings Considering the South Line of Lot 1, Block 83 of the Plat of the Town of Fort Collins as bears North 89�42'48" West. LIMITS OF 100-YR FLOOD FRINGE / / / / / / / / / / / / / / / / / / / / / / / / / / / / It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Preliminary Drainage Letter for Canyon Place dated December 26, 2012 by Northern EngineeringServices, Inc., shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: City of Fort Collins benchmark 6-00 Located on a catch basin at the Northwest corner of Mulberry Street and College Avenue Elevation = 4990.68 (NGVD 29 - Unadjusted) City of Fort Collins benchmark 1-11 Located on the Southeast corner of Mulberry Street and Loomis Avenue, at the northeast corner of a concrete traffic signal base Elevation = 5005.44 (NGVD 29 - Unadjusted) 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: a. NONE CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed priorto any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Preliminary Drainage Letter for Canyon Place dated December 26, 2012 by Northern Engineering Services, Inc., shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the Fort Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO K��� ����'� �����. C��� ������ ��� ���. R City UTILITY of Fort PLAN Collins, APPROVAL Colorado Date Date Date Date Date Date APPROVED: City Engineer Traffic Engineer Parks & Recreation Stormwater Utility Water & Wastewater Utility CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 12.26.12 PROJECT: 838-002 Sheet Of 12 Sheets CANYON PLACE T���� �������� ��� ����������� �� ������� �������� �� N������� E���������� S�������, I��. ��� ��� ��� �� �� ���� ��� ��� ���� �� ������������ ������ ������ ��� ������ �� � P����������� E������� �� ��� ������ �� N������� E���������� S�������, I��. NOT FOR CONSTRUCTION REVIEW SET 12.26.12 200 S���� C������ A�����, S���� 010 F��� C������, C������� 80524 E N G I N E E R I N G � � � � � � �� PHONE: 970.221.4158 FAX: 970.221.4159 ���.�������������������.��� C2.00 UTILITY PLAN LANDSCAPE ARCHITECT ARCHITECT CANYON PLACE The Architects' Studio Jeff Errett 151 W. Mountain Ave. Fort Collins, CO 80524 (970) 482-8450 Landworks Design, Inc. Chad Herd, ASLA 3457 Ringsby Court Denver, CO 80261 (303) 433-4257 E N G I N E E R I N G � � � � � � �� E N G I N E E R I N G � � � � � � �� CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO K��� ����'� �����. C��� ������ ��� ���. R City UTILITY of Fort PLAN Collins, APPROVAL Colorado Date Date Date Date Date Date APPROVED: City Engineer Traffic Engineer Parks & Recreation Stormwater Utility Water & Wastewater Utility CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CONTACT INFORMATION PROJECT TEAM: GAS----------------- Xcel Energy----------------------------- Stephanie Rich (970) 225-7857 ELECTRIC-------- City of Fort Collins Light & Power-- Doug Martine (970) 224-6152 CABLE------------- Xfinity-------------------------------------- Don Kapperman (970) 567-0425 TELECOM.--------Centurylink------------------------------- William Johnson (970) 377-6401 WATER------------ City of Fort Collins Utilities----------- Roger Buffington (970) 221-6700 WASTEWATER--City of Fort Collins Utilities----------- Roger Buffington (970) 221-6700 STORMWATER- City of Fort Collins Utilities----------- Glen Schlueter (970) 221-6700 UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER SHEET INDEX I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: BENCHMARK #1: City of Fort Collins Benchmark 6-00 Located on a catch basin at the northwest corner of Mulberry Street and College Avenue. Elevation = 4990.68 (NGVD 29 - Unadjusted) BENCHMARK #2: City of Fort Collins Benchmark 1-11 Located on the Southeast corner of Mulberry Street and Loomis Avenue, at the northeast corner of a concrete traffic signal base. Elevation = 5005.44 (NGVD 29 - Unadjusted) Basis of Bearings Considering the South Line of Lot 1, Block 83 of the Plat of the Town of Fort Collins as bears North 89�42'48" West. Northern Engineering Services, Inc NE Project No. 838-002 Date: June 11, 2012 ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: PROJECT LOCATION VICINITY MAP NORTH 1"=1000' 1-2 PLAT (FOR REFERENCE ONLY) SiteWise, LLC 7000 N. Broadway Building 3, Suite 306 Denver, Colorado 80221 (303) 650-8680 SUBSURFACE UTILITY LOCATES** C4.00 FLOODPLAIN EXHIBIT