HomeMy WebLinkAboutREMINGTON ROW (ANNEX) - PDP - PDP110017 - SUBMITTAL DOCUMENTS - ROUND 3 - MODIFICATION REQUESTStrength in design.
401 W. Mountain Ave, Suite 100 Fort Collins, CO 80521 tel. 970.224.1191 fax 970.224.1662 www.theartofconstru
March 1, 2013
City of Fort Collins
Community Development & Neighborhood Services
281 North College Ave.
P.O. Box 580
Fort Collins, CO 80522
Attention: Courtney Levingston
Re: Revised Modification to Standards for the Remington
Dear Courtney:
VFLA is respectfully requesting Modification of the
Row project:
1. Modification to Division 4.9(D)(6)(d)
every 2’ wall height in excess to 18'.
Code Language: Minimum side yard width shall be five (5) feet for all interior side yards. Whenever any portion of
a wall or building exceeds eighteen (18) feet in height, such portion of the wall or building shall be set back from
the interior side lot line an additional one (1) foot, beyond the minimum required, for each two (2) feet or fraction
thereof of wall or building height that excee
fifteen (15) feet on the street side of any corner lot. Notwithstanding the foregoing, minimum side yard width for
school and place of worship uses shall be twenty
In our previous submittal we proposed a building with
planes facing the north and south side yards for
side, three stories of apartments on the west side and a
was the stair tower mass that was not compliant with Division 4.9(D)(6)(d) for which we were request
modification of standards. Through discussions with City Staff we decided to move the exterior door to the exit
stair so that the entire stair could be un
tower. However, a clarification of the standard of Division 4.9(D)(6)(d) revealed that tallest of the remaining walls
on both the north and south property lines were also non
An illustration of the relationship between these
attached Fig. 1. This illustration also lists the maximum height of each wall plane, the required setback as
prescribed by Division 4.9(D)(6)(d) and the
can be seen, efforts have been made to reduce the length
design. Strength in partnership. Strength in community.
401 W. Mountain Ave, Suite 100 Fort Collins, CO 80521 tel. 970.224.1191 fax 970.224.1662 www.theartofconstru
Community Development & Neighborhood Services
Modification to Standards for the Remington Row project
LA is respectfully requesting Modification of the following Standards of the City’s Planning Code for the Remington
4.9(D)(6)(d) in regards to the increase of the 5’ side yard setback an additional 1’ for
every 2’ wall height in excess to 18'.
Minimum side yard width shall be five (5) feet for all interior side yards. Whenever any portion of
ds eighteen (18) feet in height, such portion of the wall or building shall be set back from
the interior side lot line an additional one (1) foot, beyond the minimum required, for each two (2) feet or fraction
thereof of wall or building height that exceeds eighteen (18) feet in height. Minimum side yard width shall be
fifteen (15) feet on the street side of any corner lot. Notwithstanding the foregoing, minimum side yard width for
school and place of worship uses shall be twenty-five (25) feet (for both interior and street sides).
In our previous submittal we proposed a building with three main building masses that define
planes facing the north and south side yards for the Remington Row project; two stories of apartments on the east
side, three stories of apartments on the west side and a vestibule for an exterior stair tower that connects them.
was the stair tower mass that was not compliant with Division 4.9(D)(6)(d) for which we were request
modification of standards. Through discussions with City Staff we decided to move the exterior door to the exit
stair so that the entire stair could be un-enclosed and thereby eliminating the non-
ication of the standard of Division 4.9(D)(6)(d) revealed that tallest of the remaining walls
on both the north and south property lines were also non-compliant.
An illustration of the relationship between these two remaining wall planes as currently prop
attached Fig. 1. This illustration also lists the maximum height of each wall plane, the required setback as
prescribed by Division 4.9(D)(6)(d) and the actual setback that is being provided by this proposed design.
fforts have been made to reduce the length and height of this section of wall as much as possible,
community.
401 W. Mountain Ave, Suite 100 Fort Collins, CO 80521 tel. 970.224.1191 fax 970.224.1662 www.theartofconstruction.com
401 W. Mountain Ave, Suite 100 Fort Collins, CO 80521 tel. 970.224.1191 fax 970.224.1662 www.theartofconstru
including not enclosing the stair as described above
4.9(D)(6)(d) becomes nominal and inconsequenti
modification of standards based on the provisions of Division 2.8.2(H)(4).
2. Modification to Division 3.2.1(E)(2
Code Language: Foundation Plantings. Exposed sections of building walls that are in high
areas of the building exterior shall have planting beds at least five (5) feet wide placed directly along at least fifty
(50) percent of such walls.
The attached Figure 2. illustrates the visual impact that a five foot wide planting bed as required by Division
3.2.1(E)(2)(d) would have along the west side of one of the proposed buildings. This illustration represents two
staggered rows of feather reed grass
During the most recent meeting with the Landmark Preservation Commission the importance of aligning the face
of the proposed buildings with the setback facing Remington Street established
site was re-emphasized. This setback
required by LUC 4.9(D)(6)(b). This pushes the structures farther back on the property and limits the amount of
space available for parking and landscaping on the rear portion of the lot. The
optimized for efficiency of space including the
vehicle circulation. The building footprint has also
common areas to code minimums.
buildings and the parking lot which i
the west side of the buildings has a pl
significant wall plane. The remainder of the landscaping planting area available is 1 foot a
After establishing the maximum area that could be made available
would support viable vegetation in t
what is required by LUC Division 3.2.1(E)(2)(d)
minimal planting bed but can provide an extensive amount of cover over time. In order to protect the buildings
from the climbing plants a free-standing trellis and
off the face of the buildings. In the areas with planting beds three feet wide and greater a single row of feather
reed grass will be planted in front of the trellis and
planting configuration along one of the proposed buildings.
By comparing Figure 2 to the proposed p
screening provided by the proposed
Therefore, the Remington Row project should be granted this modification of standards based on the provisions
of Division 2.8.2(H)(1).
Thank you for your consideration of these requests.
Sincerely,
Jeff Hansen
401 W. Mountain Ave, Suite 100 Fort Collins, CO 80521 tel. 970.224.1191 fax 970.224.1662 www.theartofconstru
as described above, so that the diversion from the standard set in Division
nominal and inconsequential. Therefore, the Remington Row
modification of standards based on the provisions of Division 2.8.2(H)(4).
E)(2)(d) in regards to the required 5 foot wide foundation plantings.
Foundation Plantings. Exposed sections of building walls that are in high
areas of the building exterior shall have planting beds at least five (5) feet wide placed directly along at least fifty
The attached Figure 2. illustrates the visual impact that a five foot wide planting bed as required by Division
3.2.1(E)(2)(d) would have along the west side of one of the proposed buildings. This illustration represents two
reed grass obscuring exactly 50% of the west facing foundations.
During the most recent meeting with the Landmark Preservation Commission the importance of aligning the face
of the proposed buildings with the setback facing Remington Street established by the existing structures on the
setback is 19 feet, 9 inches from the east property line
. This pushes the structures farther back on the property and limits the amount of
e for parking and landscaping on the rear portion of the lot. The depth of the parking lot has been
optimized for efficiency of space including the use of compact parking stalls and the
footprint has also been optimized by designing efficient
common areas to code minimums. The resulting design results in a planting bed between the west side of the
buildings and the parking lot which is only 3 feet and 3 inches wide extending for 52% of each building. 31% of
the west side of the buildings has a planting area greater than 5 feet, a majority of which is not a part of the most
he remainder of the landscaping planting area available is 1 foot a
After establishing the maximum area that could be made available a landscaping solution
in the narrow area available and provide visual screening
32' - 6"
18' - 4"
GROUND PLANE
WALL PLANE A1
WALL HEIGHT: 18'-4"
SETBACK REQUIRED: 6'-0"
SETBACK PROVIDED: 5'-11"
34' - 7"
WALL PLANE A2
WALL HEIGHT: 32'-6"
SETBACK REQUIRED: 13'-0"
SETBACK PROVIDED: 12'-3"
FINISH FLOOR
6"
ROOFS, EAVES AND TRIM HAVE BEEN OMMITED FROM THIS ILLUSTRATION FOR CLAIRTY
PORTION OF WALL THAT DEVIATES FROM
THE STANDARD OF DIVISION 4.9(D)(6)(d)
(4.6 SF OF WALL IS 9" TOO CLOSE)
PORTION OF WALL THAT DEVIATES FROM
THE STANDARD OF DIVISION 4.9(D)(6)(d)
(4.6 SF OF WALL IS 9" TOO CLOSE)
23' - 3"
36' - 10"
GROUND PLANE
WALL PLANE C1
WALL HEIGHT: 23'-3"
SETBACK REQUIRED: 8'-0"
SETBACK PROVIDED: 8'-4"
WALL PLANE C2
WALL HEIGHT: 36'-10"
SETBACK REQUIRED: 15'-0"
SETBACK PROVIDED: 14'-8"
FINISH FLOOR
1' - 3"
34' - 7"
ROOFS, EAVES AND TRIM HAVE BEEN OMMITED FROM THIS ILLUSTRATION FOR CLAIRTY
PORTION OF WALL THAT DEVIATES FROM
THE STANDARD OF DIVISION 4.9(D)(6)(d)
(3.9 SF OF WALL IS 4" TOO CLOSE)
Scale
Project number
Date
Drawn by
Checked by
401 W. Mountain Ave., Suite 100
Fort Collins, CO 80521
ph: 970.224.1191
www.theartofconstruction.com
VAUGHT FRYE LARSON architects
1/8" = 1'-0"
705 REMINGTON STREET
FORT COLLINS, CO
12/19/12 Fig. 1
RJH
RJH
SIDEYARD SETBACKS
2011-47
REMINGTON ROW
1/8" = 1'-0"
1 NORTH PROPERTY LINE
Illustration of Visual Impact of 5-Foot Wide Foundation Planting for 50%
of High-Use Building Exterior as Required per LUC Section 3.2.1(E)(2)(d)
Scale
Project number
Date
Drawn By
Checked by
401 West Mountain Avenue Suite 100 Fort Collins, CO 80521
ph: 970.224.1191 www.theartofconstruction.com
VAUGHT FRYE LARSON aaaarrrrcccchhhhiiiitttteeeeccccttttssss
1/8" = 1'-0"
705 REMINGTON STREET
FORT COLLINS, CO
02/28/13
RJH
FOUNDATION PLANTINGS
2011-47
REMINGTON ROW
RJH Fig. 2
CEDAR LATTICE WITH
CLIMBING VINES
TIMBER FRAME TRELLIS
52% OF WALL WITH 3'-3" PLANTING BED
BED
1'-7" PLANTING
BED GREATER THAN 5'-0"
31% OF WALL WITH PLANTING
Illustration of Visual Impact of Proposed Foundation Plantings as
Described in Request for Modification of Standard Required By
LUC Section 3.2.1(E)(2)(d)
Scale
Project number
Date
Drawn By
Checked by
401 West Mountain Avenue Suite 100 Fort Collins, CO 80521
ph: 970.224.1191 www.theartofconstruction.com
VAUGHT FRYE LARSON aaaarrrrcccchhhhiiiitttteeeeccccttttssss
1/8" = 1'-0"
705 REMINGTON STREET
FORT COLLINS, CO
03/01/13
RJH
FOUNDATION PLANTINGS
2011-47
REMINGTON ROW
RJH Fig. 3
1/8" = 1'-0"
2 SOUTH PROPERTY LINE
by LUC Division 3.2.1(E)(2)(d). The proposed solution uses a climbing vine
minimal planting bed but can provide an extensive amount of cover over time. In order to protect the buildings
standing trellis and lattice structure will be constructed about eight to twelve inches
off the face of the buildings. In the areas with planting beds three feet wide and greater a single row of feather
reed grass will be planted in front of the trellis and climbing vines. The attached Figure 3
planting configuration along one of the proposed buildings.
the proposed planting solution in Figure 3 it can be clearly seen that the foundation
screening provided by the proposed planting is significantly better than what is required
Therefore, the Remington Row project should be granted this modification of standards based on the provisions
these requests.
401 W. Mountain Ave, Suite 100 Fort Collins, CO 80521 tel. 970.224.1191 fax 970.224.1662 www.theartofconstruction.com
diversion from the standard set in Division
Row project should be granted this
in regards to the required 5 foot wide foundation plantings.
Foundation Plantings. Exposed sections of building walls that are in high-use or high-visibility
areas of the building exterior shall have planting beds at least five (5) feet wide placed directly along at least fifty
The attached Figure 2. illustrates the visual impact that a five foot wide planting bed as required by Division
3.2.1(E)(2)(d) would have along the west side of one of the proposed buildings. This illustration represents two
obscuring exactly 50% of the west facing foundations.
During the most recent meeting with the Landmark Preservation Commission the importance of aligning the face
by the existing structures on the
from the east property line rather than the 15 feet
. This pushes the structures farther back on the property and limits the amount of
depth of the parking lot has been
use of compact parking stalls and the designation of one-way
been optimized by designing efficient unit layouts and reducing
The resulting design results in a planting bed between the west side of the
for 52% of each building. 31% of
anting area greater than 5 feet, a majority of which is not a part of the most
he remainder of the landscaping planting area available is 1 foot and 7 inches wide.
a landscaping solution was developed that
he narrow area available and provide visual screening equal to or better than
d solution uses a climbing vine that requires a very
minimal planting bed but can provide an extensive amount of cover over time. In order to protect the buildings
lattice structure will be constructed about eight to twelve inches
off the face of the buildings. In the areas with planting beds three feet wide and greater a single row of feather
he attached Figure 3 represents this proposed
it can be clearly seen that the foundation
planting is significantly better than what is required by Division 3.2.1(E)(2)(d).
Therefore, the Remington Row project should be granted this modification of standards based on the provisions
the City’s Planning Code for the Remington
in regards to the increase of the 5’ side yard setback an additional 1’ for
Minimum side yard width shall be five (5) feet for all interior side yards. Whenever any portion of
ds eighteen (18) feet in height, such portion of the wall or building shall be set back from
the interior side lot line an additional one (1) foot, beyond the minimum required, for each two (2) feet or fraction
ds eighteen (18) feet in height. Minimum side yard width shall be
fifteen (15) feet on the street side of any corner lot. Notwithstanding the foregoing, minimum side yard width for
nterior and street sides).
three main building masses that defined the three wall
two stories of apartments on the east
stair tower that connects them. It
was the stair tower mass that was not compliant with Division 4.9(D)(6)(d) for which we were requesting the
modification of standards. Through discussions with City Staff we decided to move the exterior door to the exit
-compliant mass of the stair
ication of the standard of Division 4.9(D)(6)(d) revealed that tallest of the remaining walls
as currently proposed is shown on the
attached Fig. 1. This illustration also lists the maximum height of each wall plane, the required setback as
setback that is being provided by this proposed design. As it
of this section of wall as much as possible,