HomeMy WebLinkAboutMAX FLATS - PDP - PDP120034 - PLANS - UTILITY PLANS (3)IPC WASTE AND WATER FIXTURE UNIT CALCULATION
PROJECT:
BUILDING: CODE: DATE:
WASTE FIXTURES UNITS
FIXTURE FIXTURE COLD COLD HOT HOT COLD COMBINED FIXTURE TOTAL
TOTAL TYPE OCC. SUPPLY TYPE WATER TOTAL WATER TOTAL & HOT TOTAL VALUES VALUES REMARKS
96 BATHROOM GROUP PRIVATE FLUSH TANK 2.70 259.2 1.50 144.0 3.60 345.6 5.00 480.0
BATHTUB OR COMBINATION BATH/SHOWER PRIVATE FAUCET 1.00 0.0 1.00 0.0 1.40 0.0 2.00 0.0
1 HOSE BIBBS PRIVATE 1/2" VALVE 2.50 2.5 0.0 2.50 2.5 0.0
3 HOSE BIBBS ADDITIIONAL PRIVATE 1/2" VALVE 1.00 3.0 0.0 1.00 3.0 0.0
64 KITCHEN SINK PRIVATE FAUCET 1.00 64.0 1.00 64.0 1.40 89.6 2.00 128.0
64 DISHWASHER PRIVATE AUTOMATIC 0.0 1.40 89.6 1.40 89.6 2.00 128.0
64 LAVATORY PRIVATE FAUCET 0.50 32.0 0.50 32.0 0.70 44.8 1.00 64.0
SHOWER HEAD PUBLIC MIX VALVE 3.00 0.0 3.00 0.0 4.00 0.0 2.00 0.0
SHOWER HEAD PRIVATE MIX VALVE 1.00 0.0 1.00 0.0 1.40 0.0 2.00 0.0
64 WASHING MACHINE (8 LB) PRIVATE AUTOMATIC 1.00 64.0 1.00 64.0 1.40 89.6 2.00 128.0
1 DRINKING FOUNTAIN OFFICES 3/8" VALVE 0.25 0.0 0.0 0.25 0.3 0.50 0.0
1 LAVATORY PUBLIC FAUCET 1.50 0.0 1.50 1.5 2.00 2.0 1.00 0.0
1 WATER CLOSET PUBLIC FLUSH TANK 5.00 0.0 0.0 5.00 5.0 4.00 0.0
1 SERVICE SINK OFFICES FAUCET 2.25 2.3 2.25 2.3 3.00 3.0 2.00 2.0
TOTAL
FIXT. UNITS 426.95 397.35 674.95 930.00 TOTAL FIXTURE UNITS
GPM 110.0 104 118 8" BUILDING MAIN SIZE
PIPE SIZE 3" 2-1/2" 3" 1/8" BUILDING MAIN SLOPE
WATER SERVICE LINE SIZE FT/SEC PSI/100FT
TAP & METER 3" tap 5.00 2.00
BFP & BLDG MAIN
CONTRACTOR TO PROVIDE THEIR OWN FIXTURE UNIT CALCULATION FOR ORDERING FIXTURES.
CALCS USED ASSUMING THERE ARE 2 BATHROOM GROPS EACH FOR THE 2 AND 3 BEDROOM
UNITS, THAT EACH UNIT HAS 1 DISHWASHER, 1 CLOTHES WASHER AND 1 EACH KITCHEN SINK.
IT WAS ALSO ASSUMED THAT ALL FOUR LEVELS WERE IDENTICAL BASED ON INFORMATION
RECEIVED.
PUBLIC FIXTURES WERE ASSUMED TOTALS BASED ON PREVIOUS PROJECTS AND IT WAS ALSO
ASSUMED THAT THERE IS NO POOL AT THIS FACILITY.
203 W. MULBERRY-FORT COLLINS
2009 IPC 2/15/2012
WATER FIXTURE UNITS
NOTES
3" TAP, 3" MAIN DISTRIBUTION
NOTE: THE ABOVE FIXTURE UNIT COUNTS ARE PRELIMINARY. THESE ARE
BASED ON ASSUMPTION FROM PAST SIMILAR PROJECTS