HomeMy WebLinkAbout7-ELEVEN @ COLLEGE & MAGNOLIA - PDP/APU - PDP120026 - SUBMITTAL DOCUMENTS - ROUND 2 - VARIANCE REQUESTDecember 3, 2012 Mr. Mark Virata, P.E. Engineering Development Review City of Fort Collins 281 North College Avenue Ft. Collins, CO80522 RE: 7-Eleven – College and Magnolia Project Development Plan – Variance Request REG Project # 120805 Dear Mark: On behalf of the applicant of the abovementioned project, the purpose of this letter is to request approval to a variance of certain City of Fort Collins (City) engineering design standards that are listed in the Larimer County Urban Area Street Standards (LCUASS). The specific code is listed below with the applicant’s reason to request the variance. Code: 7.4.1 (Alignment) Tables 7.1-7.3 General Parameters (pertaining to driveway access) Identifying Issue and Proposed Alternate design: South College Avenue is sized as a 4 lane arterial (140-ft right of way width). The requirements for driveway access include:  Limited access,  Distance between driveway edges: 460-ft- 660-ft (distances less than 460-ft require and administrative variance to be approved)  Corner clearance between driveways and street intersections (460-ft - 660-ft) West Magnolia Street is sized as a minor collector (100-ft right of way width). The requirements for driveway access include:  Limited access,  Distance between driveway edges: 30 -ft  Corner clearance between driveways/alleys and street intersections: 100-ft minimum (distances less than 100-ft require and administrative variance to be approved) The current configuration of the parcel along South College Avenue has one vehicular access point. There are two vehicular access points along the West Magnolia Street frontage. The applicant is proposing with the development of this parcel of land to close one vehicular access points to West Magnolia, and to provide a perimeter sidewalk with ADA compliant pedestrian crossings at each access point, including truncated domes at the proposed driveway crossings as well as the existing intersection curb ramps. 7-Eleven College and Magnolia Design Variance Request December 3, 2012 Mark Virata, PE The lot frontage along South College is approximately 100.0 feet, making the 460’ minimum requirement for corner clearance impossible to meet. The proposed development maintains the existing access point location along South College, providing a distance of 92’ from the College and Magnolia Intersection. The distance from the neighboring driveway entrance to the north is currently approximately 76’. This distance will not be modified with the proposed development. The new driveway entrance will be improved with the addition of truncated domes for pedestrians. The lot frontage along West Magnolia is approximately 190’. The development proposes to keep the access point that is furthest away from the College Avenue/ Magnolia Street Intersection and close the closest one. This proposal will increase the corner clearance from approximately 95’ to approximately 173’, well above the minimum requirement of 100’. The required minimum distance between a driveway edges 30’. The proposed location of the drive entrance is approximately 27’ from the existing alley. While the proposed configuration does not meet the current standard, it improves the driveway intersection in the following ways:  Pedestrian/ ADA crossings will be constructed.  Signage and pavement markings will be constructed that mitigate for pedestrian/ vehicular conflicts.  Sight distances will be identified and obstructions will not be placed within or can be removed from these areas. Justification: This variance if granted will improve the existing conditions including minimizing the detriment to the public health by removing one of the entrances along Magnolia Street, improve safety and welfare by adding truncated domes at the vehicular crossings, and will not reduce design life of the improvement nor cause the city of Fort Collins additional maintenance costs. Thank you very much for your consideration of this matter. Should you require additional information or would like to meet on this issue I can be reached at ksukalski@rothengineering.com or by phone 303- 841-9365. Sincerely, ROTH ENGINEERING GROUP, LLC Kevin S. Roth, P.E. LEED AP Managing Member