Loading...
HomeMy WebLinkAbout7-ELEVEN @ COLLEGE & MAGNOLIA - PDP/APU - PDP120026 - SUBMITTAL DOCUMENTS - ROUND 2 - PHOTOMETRIC PLAN0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.9 1.0 0.9 0.8 0.6 1.2 1.1 1.2 0.5 0.0 0.0 0.0 0.1 1.1 0.8 0.8 1.1 0.5 0.1 0.0 0.0 0.0 0.0 0.1 0.1 2.0 2.3 2.2 1.6 0.9 0.4 2.7 1.1 0.2 0.1 0.0 0.0 0.0 0.1 0.1 1.6 2.8 2.9 1.4 0.8 0.4 2.4 0.6 0.1 0.1 0.0 0.0 0.1 0.2 1.5 3.0 2.2 1.5 1.0 0.6 2.0 0.6 0.1 0.1 0.1 0.1 0.1 0.2 1.5 3.2 2.4 1.8 1.3 0.7 3.1 0.8 0.2 0.1 0.1 0.1 0.1 0.2 1.8 3.2 3.6 2.3 1.8 2.0 1.7 0.6 1.5 2.1 0.9 0.4 0.6 1.1 2.8 4.2 2.6 2.3 0.7 0.3 0.2 0.1 0.0 0.1 0.2 2.3 3.0 3.2 3.2 2.9 2.6 1.7 1.0 0.8 0.9 0.8 0.8 1.2 1.9 3.3 4.1 2.9 1.5 0.6 0.4 0.2 0.1 0.0 0.0 0.3 1.2 1.8 2.2 3.3 3.0 3.1 2.8 1.7 1.0 0.9 1.0 1.4 2.0 3.2 4.4 4.8 3.5 2.7 0.9 0.4 0.2 0.1 0.0 0.0 0.1 0.4 0.5 1.1 2.1 2.0 2.5 2.7 1.9 1.3 1.1 1.2 1.6 2.9 2.9 3.6 4.0 4.4 2.4 0.8 0.4 0.2 0.1 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.5 1.7 2.3 1.9 1.2 1.1 1.2 1.5 2.1 2.0 1.8 2.9 2.7 1.9 0.9 0.4 0.2 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.4 1.1 1.2 1.0 0.7 0.6 0.5 0.5 0.6 0.7 1.0 1.0 0.9 0.4 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.4 0.6 0.4 0.3 0.2 0.2 0.3 0.4 0.5 0.4 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.0 0.0 0.0 BASE HT=3' POLE HEIGHT=17' ADDITIONAL EQUIPMENT 20ft 20ft (4) PS4S17CTBZ 17 x 4 x .125" SQUARE STEEL POLE (4) PD-1H4 SINGLE TENON POLE AND FIXTURE MEETS 140 MPH SUSTAINED WINDS Lwy-3MB & LWY-4MB GN GN GN GN GN GN GN GN SOUTH COLLEGE AVENUE (140' ROW) WEST MAGNOLIA STREET (100' ROW) ALLEY (20' ROW) Date:11/29/2012 1200 92nd Street - Sturtevant, WI 53177 www.cree.com - (800) 236-6800 Illumination results shown on this lighting design are based on project parameters provided to Cree, Inc. used in conjunction with luminaire test procedures conducted under laboratory conditions. Actual project conditions differing from these design parameters may affect field results. The customer is responsible for verifying dimensional accuracy along with compliance with any applicable electrical, lighting, or energy code. Scale: 1"=16' Customer No: 09130 Filename: JC121008FCCOTGR2.AGI Layout by: TIFFANY GENTRY Footcandles calculated at grade Project Name: 7 ELEVEN FT COLLINS, CO Footcandles calculated using predicted lumen values after 50K hours of operation Label Avg Max Min Avg/Min Max/Min GRADE 0.74 4.8 0.0 N.A. N.A. Luminaire Schedule Symbol Qty Label Arrangement Total Lamp Lumens LLF Description Total Watts 3 LWY-3MB SINGLE 7508 0.930 STR-LWY-3MB-HT-08-D-UL-BZ-525mA 405 1 LWY-4MB SINGLE 8064 0.930 STR-LWY-4MB-HT-08-D-UL-BZ-525mA 135 11 GN SINGLE N.A. 0.700 GNLED13NAD gooseneck 166.1 POLE LIGHTS ARE FULLY SHIELDED CUT-OFF FIXTURES WITH ADDITIONAL BACKLIGHT SHIELDS 7-ELEVEN - COLLEGE AND MAGNOLIA