HomeMy WebLinkAboutHARMONY TECH PARK 3RD FILING, LOT 1 - FDP - FDP110008 - MAPS/GRAPHICS - SITE PLANLARIMER COUNTY
RL
HC
POL
E
UE
E
RL
LMN
MMN
RL
CSU
CC
E
E
LMN
LMN
RL
RL
UE
UE
LMN
HC
HC HC HC
HC
LMN
LMN
RL
RL
RL RL
HC
RL
HC
VICINITY MAP
SITE
HC
LARIMER COUNTY
HC
HC
RL
HC
24'' ST 24'' ST
24'' ST 24'' ST 24'' ST 24'' ST 24'' ST
24'' ST
12'' W 12'' W 12'' W
12'' W
12'' W
24'' W 24'' W 24'' W 24'' W 24'' W
E
E
2'' W 2'' W
T
G G
10
23
26
27
24
15
25
31
86'-10"
24'
9'
TYP.
22'-01
2"
7' 17' 24' 17' 25'
ELECTRICAL
TRANSFORMER
(BY OTHERS)
103'-2"
86'-01
2"
106'-11"
TRASH /
RECYCLING
ENCLOSURE
5' WALK
TRASH /
RECYCLING
ENCLOSURE
KNOX BOX
KNOX BOX
24'
24'
15'
10'
10'
5'
5'
7'-6"
24' 19' 19' 24' 17'
14'-71
2"
24'
5'
5'
19
PA
PA
PA
PA
PA
PA
PA
PA PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA PA
PA
PA
PA
PA
PA
PA PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PRECISION DRIVE
TECHNOLOGY PARKWAY
ROCK CREEK DRIVE
FDC
WALKWAY
SIDEWALK
WALKWAY
SIDEWALK
SIDEWALK
WALKWAY
24'-6"
17' 24' 17'
25'
26'-61
2"
17' 24' 17'
PROPERTY LINE
PA
PA
PA
PA PA
ADA RAMP
ADA RAMP
8'
8'
MIN.
8'
8" WATER (FIRE)
2" WATER
SANITARY SEWER
SIDEWALK - EXISTING
EXISTING STREET LIGHT
EXISTING STREET LIGHT
EXISTING
STREET LIGHT
EXISTING
STREET LIGHT
EXISTING FIRE
HYDRANT
EXISTING FIRE
HYDRANT
BIKE RACK (1)
ADA
RAMP
ADA
RAMP
ADA RAMP
ADA
RAMP
ADA
RAMP
ADA
RAMP
ADA
RAMP
ADA
RAMP
BIKE RACK (1)
BIKE RACK (1)
BIKE RACK (1)
BIKE RACK (1)
PA
FEATURE WALL /
SEAT WALL, TYP.
ADA
RAMP
WALKWAY
PA
PA
PA
PA
PA
NAT. GAS SERVICE
ELECTRICAL
SERVICE
5'
BOLLARD, TYP.
BIKE RACK (1)
COBBLE
SWALE, TYP.
SWALE, TYP.
ADA
RAMP
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
10'
LOADING
DOCK AREA
PA
24'
0 15 30 60
APPROVED BY THE DIRECTOR OF PLANNING OF THE CITY OF FORT COLLINS,
COLORADO ON THIS DAY OF ,A.D., 20
DIRECTOR OF PLANNING
DIRECTOR OF PLANNING
KNOW ALL MEN BY THESE PRESENT THAT:
By: MAV Development Company
Date:_________________, _______
STATE OF COLORADO )
) ss.
COUNTY OF LARIMER )
WITNESS my hand and official seal.
Notary Public
My commission expires: __________________
Owner: Harmony Technology Park, LLC a Colorado Limited Liability Company
OWNERSHIP CERTIFICATION
Harmony Technology Park, LLC a Colorado Limited Liability Company and/or assigns being all the
lawful recorded owners of the property shown on this development plan, except any existing public
streets, roads, or highways, do hereby certify that I/we accept the conditions and restrictions set forth
on said plan and in the conditions of approval by the City of Fort Collins, dated
_______________________, and that I/we consent to the recordation of any information pertaining
thereto.
The foregoing instrument was acknowledged before me this ________ day of ______________,
__________ by .
LAND USE DATA
LEGAL DESCRIPTION
BICYCLE PARKING REQUIRED PROVIDED
BICYCLE PARKING 10 12
TOTAL 155 200
HANDICAPPED ACCESSIBLE PARKING
REGULAR PARKING 192
8
PARKING ALLOWED PROVIDED
PROPOSED LAND USE OFFICE / INDUSTRIAL
6 Stories
4.919 ACRES
MAX. BUILDING HEIGHT PERMITTED
EXISTING ZONING
GROSS SITE AREA
HC- HARMONY CORRIDOR
0.23
ESTIMATED FLOOR AREA 49,900 S.F.
FLOOR AREA RATIO
NET SITE AREA
PUBLIC ROW: 0 S.F.
MAX. BUILDING HEIGHT PROPOSED 1 Story
SITE COVERAGE AREA PERCENT
39%
38%
0%
100%
23%
83,552 S.F.
0 S.F.
80,817 S.F.
214,269 S.F.
BUILDING COVERAGE 49,900 S.F.
DRIVES AND PARKING
OPEN SPACE
PUBLIC R.O.W.
TOTAL
HARMONY TECHNOTOGY PARK THIRD FILING, FIRST REPLAT
CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO.
CONTAINING 4.919 ACRES MORE OR LESS.
4.919 ACRES
GENERAL NOTES
1. Refer to Utility Plan for location of utilities and drainage facilities.
2. Developer shall ensure that the Landscape Plan is coordinated with the plans done by other consultants so
that the proposed grading, storm drainage, or other construction does not conflict nor preclude installation
and maintenance of landscape elements.
3. Sidewalks and ramps shall be constructed in compliance with the Americans With Disabilities Act.
Handicap accessible routes shall slope no more than 1:20 in direction of travel and no more than 1:48
cross slope.
4. Building-mounted and pole-mounted light fixtures shall feature sharp cut-off, down- directional luminaries.
5. Signage to comply with City of Fort Collins Sign Code.
6. Trees shall be offset a minimum of 4' from gas lines including service from the main to the meter location.
7. Rooftop and ground-mounted mechanical equipment shall be screened from public view.
8. Bike racks shall accommodate 2 bikes per rack min.
LEGEND
PA
PARKING COUNT
PLANTING AREA
X
TOTAL 49,900 S.F.
INDUSTRIAL
OFFICE
BUILDING USES
UNKNOWN S.F.
UNKNOWN S.F.
Its: Manager
By:
__________________
150
5
CONSTRUCTION TYPE TYPE IIB W/TYPE 13 SPRINKLER SYSTEM
BUILDING OCCUPANCY TYPE 'B': 499 / M & F: 250