HomeMy WebLinkAboutTRANSFORT FACILITY EXPANSION - FDP - FDP110003 - MAPS/GRAPHICS - PHOTOMETRIC PLANPROJECT
DATE
DRAWN
TRANSFORT FACILITY EXPANSION
CITY OF FORT COLLINS
6570 Portner Road, Fort Collins, CO 80525
C 2009 ALLER-LINGLE-MASSEY ARCHITECTS
712 WHALERS WAY SUITE, B-100
FORT COLLINS, CO 80525
(970) 223-1820
www.aller-lingle-massey.com
PRINTED: 2/ FILE NAME: '2ÁARJQVQOGVTKEÁ4GXFYI
0843.10
7/27/10
KH
PHOTOMETRIC LAYOUT -
EXTERIOR SITE
EP-1
EXTERIOR PHOTOMETRIC CALCULATIONS
SCALE: 1" = 30'-0"
Luminaire Schedule
Symbol Qty Description Lumens LLF Description
6 N.A. 1.000 XAM3-FT-LED-119-450-CW-UE-HSS-5SQBO-S07G-19'-S-GPT-5BC
7 N.A. 1.000 XAS3-FT-LED-63-550-CW-UE
AA
BB
2 EXTERIOR POLE LIGHTING
ADDITIONS
SECTION A-A
A A
2/25/11
SINGLE POLE MOUNTED FIXTURE, FLAT GLASS LENS, HOUSE SIDE SHIELD. FORWARD THROW OPTICS. 19'-0" POLE. LED LAMPING.
SINGLE WALL FIXTURE, FLAT GLASS LENS, FORWARD THOW OPTICS. 16'-0" MOUNTING HEIGHT. LED LAMPING.
Numeric Summary
Label Units Avg Max Min Avg/Min Max/Min
GROUND EXTENDED Fc 0.13 9.7 0.1 1.3 97