October 24th, 2012
Mr. Jason Holland
City of Fort Collins Planning Department
281 North College Avenue
Fort Collins, Colorado 80522
Re: PDP Comment Response Letter
Discount Tire at North College Marketplace
Fort Collins, Colorado
Dear Mr. Holland,
Below are our responses to the PDP Review Comments letter dated October 12th, 2012.
Comment Summary:
Department: Current Planning
Contact: Jason Holland, 970-224-6126, jholland@fcgov.com
Topic: Building Elevations
Comment Number: 1 Comment Originated: 10/05/2012
10/05/2012: In tangent with comments from other staff, the transformer location needs to
be more accessible, and the electrical cabinet needs to be screened. The preferred option is
to move the cabinet to the south side of the building. The placement of a wall in front of
the building that is six feet in height is a distracting architectural element that is out of place
and is not adequate.
Response: The transformer has been moved to south of the trash enclosure. The screen wall
has been removed and landscaping has been used to screen the electrical cabinet. The
electrical cabinet is also being painted to match the face of the building.
Comment Number: 2 Comment Originated: 10/05/2012
10/05/2012: Additional wall section details need to be submitted with the plans showing
materials, offsets and depth: a detail through the herringbone brick windows, a detail
through the brick piers extending to the ground plane, and a plan detail showing the extent
of the offset for the main entrance areas.
Response: See attached sheet A.4 for required wall sections and enlarged plan of the main
entrance areas.
Comment Number: 3 Comment Originated: 10/05/2012
10/05/2012: The elevations show two graphic colors for the CMU at the top and middle of
the building, however the parapet detail specifies the same color "worsted tan". Please
clarify.
Response: Revised parapet detail to show two graphic colors for the CMU.
Comment Number: 4 Comment Originated: 10/05/2012
10/05/2012: In place of the stone cap that is proposed over the herringbone windows,
staff would like the applicant to use steel lintels to add a more distinctive look that would
make the windows a more prominent and integrated feature. The windows still look a little
"tacked on". Please refer to the example photograph that shows steel lintel caps.
Response: Per Jason Holland’s latest email, pre-cast concrete or stone cap is acceptable.
Concept elevations show pre-cast concrete cap.
Comment Number: 5 Comment Originated: 10/05/2012
10/05/2012: Please further explain the EIFS foam moulding that wraps the windows, why is
this not brick? It appears to be brick in the rendering.
Response: Replaces EIFS foam moulding with a pre-cast concrete material to match cap.
Comment Number: 6 Comment Originated: 10/05/2012
10/05/2012: Please provide a sample board of proposed exterior materials with the
re-submittal.
Response: To be submitted at a later time.
Comment Number: 7 Comment Originated: 10/05/2012
10/05/2012: Please provide more information for the CMU material. Depending on the
texture and pattern, CMU block can be a material that contributes to a building's "high
quality" appearance throughout the entire elevation, or it can look rather plain and
utilitarian. Many of the "split faced" CMU patterns provide little detail beyond basic
structural CMU. The color rendering shows a pattern that is heavily rusticated, is this the
actual intent? Please show the CMU texture material selection with the sample board, and
provide more than one texture as a design element to add detail to the building, particularly
on the south elevation.
Response: Added a combed texture CMU band in tan color to provide visual interest to the
building wall.
Comment Number: 8 Comment Originated: 10/05/2012
10/05/2012: Please explain why the CMU is being painted as opposed to integral color
throughout the building.
Response: Revised concept elevations to show integral color CMU material.
Topic: General
Comment Number: 31 Comment Originated: 10/08/2012
10/08/2012: Move the water and fire lines out of the landscape island and south landscape
area to provide required tree separation.
Response: The water and fire lines have been moved out of the landscape island and the
south landscape area.
Topic: Landscape Plans
Comment Number: 21 Comment Originated: 10/08/2012
10/08/2012: Show the parking lot boundary used to determine the 6% parking landscape
area. Staff will provide an exhibit for this to be used on the plan.
Response: Shown and labeled on landscape plan.
Comment Number: 22 Comment Originated: 10/08/2012
10/08/2012: Add Project Development Plan to the title block.
Response: Project Development Plan has been added to the title block.
Comment Number: 23 Comment Originated: 10/08/2012
10/08/2012: Additional landscaping will need to be provided along the western building
elevation, and within the eastern central median. See redline for potential configuration.
Response: Adjusted landscape per redline comment.
Comment Number: 24 Comment Originated: 10/08/2012
10/08/2012: Integrate the rock mulch edge shown on the west and south into the
landscape design. See redline.
Response: Adjusted landscape per redline comment.
Comment Number: 25 Comment Originated: 10/08/2012
10/08/2012: Show the south proposed retaining wall on the plan and adjust the southern
ornamental trees as needed. The ornamental tree to the southwest will not have enough
room.
Response: Wall has been removed.
Comment Number: 26 Comment Originated: 10/08/2012
10/08/2012: The ornamental tree in the center on the south is on an existing light pole.
Show the light poles and adjust.
Response: Light poles are shown. The trees have been adjusted.
Comment Number: 27 Comment Originated: 10/08/2012
10/08/2012: Show the proposed light poles in the parking medians.
Response: Shown on plan.
Comment Number: 28 Comment Originated: 10/08/2012
10/08/2012: The landscaping in the two islands adjacent to the handicap parking are most
likely planted too close together. This can be loosened up a bit or please explain the intent
here.
Response: These areas have been thinned out a little.
Comment Number: 29 Comment Originated: 10/08/2012
10/08/2012: The plant list needs to be expanded to provide greater and more appropriate
shrub varieties. We will forward a suggested list.
Response: The plant list has been adjusted and amended.
Comment Number: 30 Comment Originated: 10/08/2012
10/08/2012: The landscape notes will need revisions, this edit will be forthcoming from
staff. Remove the note below "plant list" that says the plant list will be refined at
construction.
Response: City requested notes have been added.
Topic: Lighting Plan
Comment Number: 18 Comment Originated: 10/08/2012
10/08/2012: Lighting plan will need to show photometric information to the boundaries of
the property.
Response: Site photometric extended to 20’ beyond the property line per subsequent review
comment.
Comment Number: 19 Comment Originated: 10/08/2012
10/08/2012: Show larger details and make sure the images are sharp enough to read.
Response: Images enlarged per request.
Comment Number: 20 Comment Originated: 10/08/2012
10/08/2012: Indicate the height of the poles, color, and show the extent and detail
information for any concrete pole bases that will be used.
Response: Pole base detail added to sheet ES1.0.
Topic: Site Plan
Comment Number: 9 Comment Originated: 10/05/2012
10/05/2012: Please add to the title block project name- Project Development Plan. Provide
a sheet index and combine the drawings into one set, adding the landscape and lighting
plans.
Response: Project Development Plan has been added to the title block. Per an email dated
10/18/12 from Jason Holland, the plans will not be combined into one set.
Comment Number: 10 Comment Originated: 10/08/2012
10/08/2012: Provide detail information on material and color of the southern landscape
wall.
Response: The southern landscape wall has been removed.
Comment Number: 11 Comment Originated: 10/08/2012
10/08/2012: Add a typical dimension for the parking stall width.
Response: A typical dimension has been added for the parking stall width.
Comment Number: 12 Comment Originated: 10/08/2012
10/08/2012: In the parking tabulations, change the heading to say "required/permitted"
instead of just "permitted".
Response: The parking tabulations heading has been revised.
Comment Number: 13 Comment Originated: 10/08/2012
10/08/2012: The total 45 parking spaces exceeds the maximum permitted.
Response: The 9 existing spaces to the north of the property should be included in the overall
development count and not specific to the Discount Tire lot.
Comment Number: 14 Comment Originated: 10/08/2012
10/08/2012: Dimension the building and trash enclosure to the west and south property
lines.
Response: These dimensions have been added.
Comment Number: 15 Comment Originated: 10/08/2012
10/08/2012: The sidewalk is too narrow in front of the electrical cabinet.
Response: The a bump-out in the sidewalk has been added in front of the electrical cabinet.
Comment Number: 16 Comment Originated: 10/08/2012
10/08/2012: The building S.F. shown needs to be gross square footage as defined in the
land use code. Please verify and remove the plus/minus symbol from the label.
Response: The gross square footage is shown without the plus/minus symbol.
Comment Number: 17 Comment Originated: 10/08/2012
10/08/2012: Additional standard notes will need to be added to the site plan.
Response: The additional standard notes provided by Jason Holland on 10/18/12 have been
added to the site plan.
Department: Engineering Development Review
Contact: Marc Virata, 970-221-6567, mvirata@fcgov.com
Topic: Construction Drawings
Comment Number: 2 Comment Originated: 10/09/2012
10/09/2012: The construction plan set has as Sheet C3, a site plan. A "site plan" isn't part of
the typical civil construction set and does not need to be included in this set, unless it is
perhaps intended to serve as a horizontal control plan. Otherwise, the site plan should be
removed from the civil set to reduce confusion on having a civil "site plan" and a planning
"site plan".
Response: The sheet is to serve as a horizontal control plan and the sheet name has been
changed to reflect this.
Comment Number: 3 Comment Originated: 10/09/2012
10/09/2012: The construction plan set needs to include on Sheet C2 the City of Fort Collins
General Notes, which are in Appendix E-1 of the Larimer County Area Street Standards.
Response: The City of Fort Collins General Notes have been added to sheet C2.
Comment Number: 4 Comment Originated: 10/09/2012
10/09/2012: The construction plan set needs a "Utility Plan Approval" block on the lower
right hand corner of all the sheets. An example of this approval block is provided with the
redlines for reference.
Response: The “Utility Plan Approval” block has been added to the plan sheets.
Comment Number: 5 Comment Originated: 10/09/2012
10/09/2012: Sheet C4, the grading plan sheet of the civil set shows notes and information
that would imply that a retaining wall(s) is being included in the design submittal, however
on the plan view, no retaining wall(s) are actually labeled or depicted with top of
wall/bottom of wall information.
Response: The retaining wall has been removed.
Comment Number: 7 Comment Originated: 10/09/2012
10/09/2012: Please ensure that appropriate construction plan details/detail sheet(s) are
provided in the civil set.
Response: Construction details have been added to the plan set.
Topic: General
Comment Number: 1 Comment Originated: 10/09/2012
10/09/2012: Please adopt one project name title to use for the project that's consistent on
all the plans for both in the title blocks and in the "title" listed in the top center of the
sheets. "Discount Tire", "Discount Tire Co. Store # Con 10001", and "Discount Tire at North
College Marketplace", could each be construed as the title of the project. It would seem
that the most appropriate title for the project would be "Discount Tire at North College
Marketplace" to help discern the project from the last Discount Tire project which was
recorded as "Discount Tire at Fossil Creek".
Response: “Discount Tire at North College Marketplace” has been added to the cover and
title block as the project name.
Topic: Site Plan
Comment Number: 6 Comment Originated: 10/09/2012
10/09/2012: The site plan appears to list the City as an owner of the property based upon
the entities listed under the owner certification. It appears that 1908 North College LLC is
the owner that should be listed on the site plan, presuming Discount Tire does not purchase
the property from the underlying developer.
Response: The owner has been changed to Halle Properties, LLC.
Department: Environmental Planning
Contact: Lindsay Ex, 970-224-6143, lex@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 10/11/2012
Consider a low-water turf species, e.g., blue grama or buffalograss instead of Kentucky
Bluegrass in your landscape plan, in compliance with Section 3.2.1 (E)(2)(3) of the Land Use
Code.
Response: The specified turf will be a low water use turf. A note / detail has been added to
the Landscape Details Sheet.
Comment Number: 2 Comment Originated: 10/11/2012
As the grading plan indicates the drainage will flow to the southwest portion of the site and
into the existing storm sewer, my comment from conceptual review is resolved.
Response: No response necessary.
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 10/09/2012
10/09/2012: The location and number of existing street trees along College differs from
what is shown on the landscape plan. Please make adjustments to reflect actual.
Response: Adjusted.
Topic: Landscape Plans
Comment Number: 2 Comment Originated: 10/09/2012
10/09/2012: The landscape curb bulge at the NE corner of the site just north of the project
entry does not have an existing tree but is shown to have one. Please add a new tree to this
location.
Response: Changed to show a proposed tree.
Comment Number: 3 Comment Originated: 10/09/2012
10/09/2012: Please direct label new trees, shrubs or other landscape plants as to the type
used that corresponds with a symbol on the plant list. The plant list should include
quantities used and percentage used.
Response: Completed as requested.
Comment Number: 4 Comment Originated: 10/09/2012
10/09/2012: Provide minimum species diversity as required in 3.2.1 D 4.
Response: Completed as requested.
Comment Number: 5 Comment Originated: 10/09/2012
10/09/2012: Add to the Landscape Notes the utility and traffic tree separation standards in
3.2.1 K 1-6
Response: Completed as requested.
Comment Number: 6 Comment Originated: 10/09/2012
10/09/2012: Please add this landscape note.
• The soil in all landscape areas, including parkways and medians, shall be
thoroughly loosened to a depth of not less than eight (8) inches and soil
amendment shall be thoroughly incorporated into the soil of all landscape areas to
a depth of at least six (6) inches by tilling, discing or other suitable method, at a
rate of at least three (3) cubic yards of soil amendment per one thousand (1,000)
square feet of landscape area.
Response: Added to Landscape Notes.
Comment Number: 7 Comment Originated: 10/09/2012
10/09/2012: Please add the tree protections standards in 3.2.1 G
Response: Added to Landscape Notes.
Comment Number: 8 Comment Originated: 10/09/2012
10/09/2012: Consider using Radiant Crab in place of Prairiefire Crab and Chanticleer Pear in
place of Autumn Blaze as they are may be more durable on this site and have a more
upright form.
Response: Amended plant list to reflect this suggestion.
Comment Number: 9 Comment Originated: 10/09/2012
10/09/2012: Please add shrubs in the rock mulch area along the west side of the building.
Response: Adjusted landscape as requested.
Comment Number: 10 Comment Originated: 10/09/2012
10/09/2012: Consider the addition of a couple of conifer trees such as Blue Spruce or
Austrian pine at the SW corner of the site in the lawn area.
Response: Two evergreen trees were removed by staff comments in an earlier submittal.
Skyrocket Junipers have been added to this area to assist in screening.
Department: Light And Power
Contact: Justin Fields, 970-224-6150, jfields@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 09/25/2012
09/25/2012: The transformer needs to be located within ten feet of an all-weather drive
over surface. Three feet of clearance is required for the sides and back of the transformer
and eight feet is required in the front of the transformer. Coordinate the transformer
location with Light and Power Engineering 970-221-6700.
Response: The transformer has been moved to south of the trash enclosure.
Comment Number: 2 Comment Originated: 09/25/2012
09/25/2012: The electric meter needs to have three feet of horizontal clearance with the
gas meter. Additionally, the electric meter needs have two feet clearance in front of the
meter to have adequate room to maintain the meter.
Response: The electric meter and gas meter are now shown three feet apart. The wall has
been removed from in front of the electric meter cabinet.
Comment Number: 3 Comment Originated: 09/25/2012
09/25/2012: A C-1 form will need to be submitted to Light and Power Engineering. The C-1
form is available online at
http://www.fcgov.com/utilities/img/site_specific/uploads/c-1_form.pdf.
Response: A C-1 form was submitted on 10/24/12.
Comment Number: 4 Comment Originated: 09/25/2012
09/25/2012: Contact Light and Power Engineering for an estimate of electric development
charges.
Response: As noted.
Department: Park Planning
Contact: Craig Foreman, 970-221-6618, cforeman@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 09/28/2012
09/28/2012: No comments
No response necessary.
Department: PFA
Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org
Topic: General
Comment Number: 01 Comment Originated: 10/10/2012
10/10/2012: Fire Department Connections shall be installed in accordance with NFPA
standards. The location of the FDC shall be approved by the fire department.
Response: The proposed FDC was coordinated with the Poudre Fire Authority and shown on
the site plan.
Comment Number: 02 Comment Originated: 10/10/2012
10/10/2012: Poudre Fire Authority requires a key box ("Knox Box") to be mounted in an
approved location on every new building equipped with a required fire sprinkler or fire
alarm system. The top shall not be higher than 6 feet above finished floor.
2006 International Fire Code 506.1 and Poudre Fire Authority Bureau Policy 88-20
Response: Knox box will be provided on the new building and will be shown on the final set of
building plans.
Comment Number: 03 Comment Originated: 10/10/2012
10/10/2012: The NFPA 13 fire sprinkler system shall be designed appropriate to the high
hazard storage commodity. Contact Joe Jaramillo at Poudre Fire Authority for details. Phone
number: 970-416-2868.
Response: Will comply to this requirement and will be shown on the final set of building
plans.
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: Building Elevations
Comment Number: 8 Comment Originated: 10/12/2012
10/12/2012: There are line/graphics over text issues on sheet A.3.
Response: See revised sheet A.3.
Topic: Construction Drawings
Comment Number: 10 Comment Originated: 10/12/2012
10/12/2012: The sub-title and legal description do not match the legal description on the
site plan.
Response: The legal description on the site plan has been updated.
Comment Number: 11 Comment Originated: 10/12/2012
10/12/2012: The Colorado State Plane NAD83(2007) Datum is a horizontal datum, not a
vertical datum. Please move the Colorado State Plane statement from the benchmark
section on sheet C1.
Response: The Colorado State Plane statement has been removed from the benchmark.
Comment Number: 12 Comment Originated: 10/12/2012
10/12/2012: The boundary line listed on sheet C1 for the basis of bearings is not along lot
7. Why are you using a line not common to lot 7?
Response: Please refer to the survey sheet C3. The basis of bearing was chosen to
correspond to the monument.
Comment Number: 13 Comment Originated: 10/12/2012
10/12/2012: The area at the northwest corner of lot 7 on sheet C3, does not reflect the
North College Marketplace Second Filing Plat. Our records do not indicate the notch out of
the corner of Lot 7.
Response: Please refer to Reception# 20110034145 provided with the submitted Plat.
Comment Number: 14 Comment Originated: 10/12/2012
10/12/2012: There are line over text issues on sheet C3, C4 & C5.
Response: Text has been revised.
Comment Number: 15 Comment Originated: 10/12/2012
10/12/2012: Please remove "lot 7" from the building on sheet C3.
Response: “Lot 7” has been removed from the building on sheet C3.
Comment Number: 16 Comment Originated: 10/12/2012
10/12/2012: There are easements that are incorrectly labeled on sheet C3 & C5.
Response: The easement labels have been revised.
Comment Number: 17 Comment Originated: 10/12/2012
10/12/2012: Please label the 30' Utility Easement at the south end of the lot on sheet C3.
Response: The 30’ Utility Easement has been labeled.
Topic: General
Comment Number: 18 Comment Originated: 10/12/2012
10/12/2012: The 8.5"x11" copy of the legal description provided, states "according to the
lots 5 and 7 adjusted boundary lines recorded June 10, 2011 at reception no.
20110034145". This document will need to be provided for review.
Response: This document has been provided with the submitted Plat.
Topic: Landscape Plans
Comment Number: 6 Comment Originated: 10/12/2012
10/12/2012: There are areas of missing text on sheet LS-01.
Response: All intended text is showing up, not sure what text is missing.
Comment Number: 7 Comment Originated: 10/12/2012
10/12/2012: The name shown in the building on sheet LS-02 is illegible.
Response: Lineweight adjusted to improve clarity.
Topic: Lighting Plan
Comment Number: 9 Comment Originated: 10/12/2012
10/12/2012: No comments.
No response necessary.
Topic: Site Plan
Comment Number: 1 Comment Originated: 10/12/2012
10/12/2012: The area at the northwest corner of lot 7, does not reflect the North College
Marketplace Second Filing Plat. Our records do not indicate the notch out of the corner of
Lot 7.
Response: Please refer to Reception# 20110034145 provided with the submitted Plat.
Comment Number: 2 Comment Originated: 10/12/2012
10/12/2012: There are line over text issues on this sheet.
Response: Text has been revised.
Comment Number: 3 Comment Originated: 10/12/2012
10/12/2012: Please remove "lot 7" from the building on this sheet.
Response: “Lot 7” has been removed from the building on the site plan.
Comment Number: 4 Comment Originated: 10/12/2012
10/12/2012: There are easements that are incorrectly labeled on this sheet.
Response: The easement labels have been revised.
Comment Number: 5 Comment Originated: 10/12/2012
10/12/2012: Please label the 30' Utility Easement at the south end of the lot.
Response: The 30’ Utility Easement has been labeled.
Department: Traffic Operation
Contact: Ward Stanford, 970-221-6820, wstanford@fcgov.com
Topic: Construction Drawings
Comment Number: 2 Comment Originated: 10/10/2012
10/10/2012: Please contact Ward Stanford (970-221-6820) for a copy of the City's traffic
control general and specific notes.
Response: Ward was contacted and the City Traffic notes were received and added to the
plans.
Topic: Traffic Impact Study
Comment Number: 1 Comment Originated: 10/10/2012
10/10/2012: TIS waived by Joe Olson per Kimley-Horn letter dated Sept 19, 2012.
Response: No response necessary.
Department: Water-Wastewater Engineering
Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com
Topic: Construction Drawings
Comment Number: 1 Comment Originated: 10/09/2012
10/09/2012: The sanitary sewer service must connect to the 8-inch sewer in the
north/south drive to the east of the site. The existing 6-inch sewer to which the service is
currently shown connecting will likely be abandoned at such time that the properties to the
south redevelop. The as-built drawings for the North College Marketplace show that a
4-inch service was extended into the site approximately 159 feet (copy of plan attached to
redlined overall utility plan sheet).
Response: Plans have been revised to connect to the 4” service. Survey only shows the
service as being stubbed 28-feet into the site, not 159 feet as the as-builts show. We are
showing worst case scenario and connecting to the stub as if it is only 28-feet into the site.
Comment Number: 2 Comment Originated: 10/09/2012
10/09/2012: Label all sewer service cleanouts in hardscaped areas (parking/drive/sidewalk
areas) as traffic-rated cleanouts and include the City's standard detail.
Response: The traffic-rated cleanout detail has been called out and included in the plan set.
Comment Number: 3 Comment Originated: 10/09/2012
10/09/2012: Why is the existing fire line stub not being used?
Response: The existing stub is 6” instead of 8”.
Comment Number: 4 Comment Originated: 10/09/2012
10/09/2012: Move the 6-inch valve on the fire line to be adjacent to the tapping saddle at
connection to the 8-inch water main.
Response: The fire line has been revised.
Comment Number: 5 Comment Originated: 10/09/2012
10/09/2012: Include the applicable standard details in the utility plan set.
Response: The standard details have been added to the plan set.
Comment Number: 6 Comment Originated: 10/09/2012
10/09/2012: The as-built drawings indicate that the meter pit was installed. If not, move
the water meter pit to a point within 2 feet of the existing curb stop.
Response: The meter pit was installed and plans have been revised.
Comment Number: 7 Comment Originated: 10/09/2012
10/09/2012: See redlined utility plans for other comments.
Response: Redlines have been addressed.
Department: Zoning
Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 10/04/2012
10/04/2012: Please provide elevation of the screening wall.
Site, landscaping and elevation plans should include locations of mechanical/utility
equipment (meters, vents, flues, conduits, RTU's, transformer...) with notes on how such
equipment will be screened.
It appears that the transformer is located on the west side of the trash enclosures. This will
also need to be inside an enclosure made of materials matching the main exterior building.
Is it possible for the electrical cabinet and gas meters be placed on the south wall? The
screen wall that is required in the proposed location blocks visibility of the limited active
store frontage along N College Ave.
Can both employee entrances along N college be articulated with the same canopy?
Response: The transformer was relocated to south of the trash enclosure. The screen wall
was removed and replaced with landscaping to screen the electrical cabinet. The steel
canopy was added to both employee entrances along North College.
Comment Number: 2 Comment Originated: 10/04/2012
10/04/2012: The applicant has requested that the code requirement for walk-in access to
the trash/recycling enclosure be "waived". At this time this requirement has not been
modified and therefore the enclosure is still required to be designed with walk-in access
without having to open a main-service gate on both enclosures.
Response: Walk-in access has been added.
Comment Number: 3 Comment Originated: 10/04/2012
10/04/2012: Land Use Code (LUC) 3.2.2(K) Is the parking maximums therefore on the site
plan under the Parking section it is not the required numbered but the allowed number.
The only requirement is to provide Accessibility spaces when any parking is being provided,
in this case 2 are required.
The two accessibility stalls that are provided appear to be at 40 degree angels. If so the stall
length is required to be 20ft. Overhang is allowed up to 2 ft., please show that any signs or
bollards are setback to accommodate such overhang.
LUC 3.2.2(C)(4) This type of use is required to provided a minimum of 4 fixed bicycle parking
spaces.
Response: The bollards are shown 2’ from the front of the stalls to provide overhang. Please
reference the accessible parking detail. Four fixed bicycle parking spaces have been added.
Comment Number: 4 Comment Originated: 10/04/2012
10/04/2012: The photometric site plan needs to cover to the property lines and 20ft
beyond.
The TWR1C light fixture is not a fully shielded light source. Please replace this fixture with a
light source that is.
Response: Site photometric extended 20’ beyond the property line. Fixture TWR1C replaced
with a full-cutoff LED fixture. See cutsheet on sheet ES1.0.
Comment Number: 5 Comment Originated: 10/04/2012
10/04/2012: Plant list needs to include the quantities of each specie
Foundation Plantings are required along sides of building that are high visibility areas.
Response: Quantities have been added to the plant list. Foundation plantings added to the
west side of the building.
Comment Number: 6 Comment Originated: 10/05/2012
10/05/2012: Please include a note on the site plan that all tire storage new and used will be
indoors.
Response: This note was added to the site plan.
Comment Number: 7 Comment Originated: 10/05/2012
10/05/2012: Reminder that signs and their locations are not approved through PDP/FDP
review process. Signs and their locations are approved through a separate sign permit.
Response: Provided a note on conceptual elevations.
Thank you in advance for your review of our plans. Should you have any questions or need
additional information, please do not hesitate to contact me at 303.228.2300.
Sincerely,
KIMLEY-HORN AND ASSOCIATES, INC.
Angela Pinley