Loading...
HomeMy WebLinkAboutTHE DISTRICT AT CAMPUS WEST - FDP - FDP120021 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLAN (7)TREE INVENTORY & MITIGATION PLAN SCALE ACCORDINGLY IF REDUCED DRAWING NUMBER: DEVELOPER / APPLICANT FT. COLLINS STUDENT HOUSING, LLC DEREK ANDERSON 1302 WAUGH DRIVE, #305 +2867217; 832.236.0400 SITE ENGINEER AND SURVEYOR NORTHERN ENGINEERING NICK HAWS, PE, LEED AP 200 S. COLLEGE AVE. SUITE 100 FORT COLLINS, CO 80524 970.221.4158 ARCHITECT HUMPHREYS & PARTNERS ARCHITECTS, L.P. YAO HUA YU, AIA, NCARB 5339 ALPHA ROAD, SUITE 300 DALLAS, TX 75240 972.701.9636 401 West Mountain Avenue Suite 100 Fort Collins, CO 80521 fax 970/224.1662 phone 970/224.5828 www.vfrdesigninc.com Ŷ land planning Ŷ landscape architecture Ŷ Ŷ urban design Ŷ entitlement Ŷ FORT COLLINS, COLORADO THE DISTRICT AT CAMPUS WEST FINAL COMPLIANCE PLAN IN ASSOCIATION WITH: PROJECT No.: R11-021 DRAWN BY: BC REVIEWED BY: LR SEAL: THIS IS A LAND USE PLANNING DOCUMENT, NOT A CONSTRUCTION DOCUMENT. REFER TO CIVIL ENGINEERING PLANS. PDP-FINAL COMPLIANCE OF 9 ISSUED No. DESCRIPTION DATE 1 PDR 08.17.11 2 PDP 01.25.12 3 PDP-FINAL COMPLIANCE 12.05.12 REVISIONS No. DESCRIPTION DATE 1 PDP RE-SUBMITTAL 02.29.12 2 REVISED FOR HEARING 03.26.12 3 MINOR AMENDMENT 10.19.12 TRAFFIC ELB ENGINEERING, LLC. ERIC L. BRACKE, P.E., P.T.O.E. 5401 TAYLOR LANE FORT COLLINS, CO 80528 970.988.7551 GEOTECH TERRACON ERIC D. BERNHARDT, P.E. 301 NORTH HOWES STREET )257&2//,16&2 970.484.0359 6 SEE LANDSCAPE PLAN, SHEET 3, FOR MITIGATION TREE LOCATIONS TREE INVENTORY AND MITIGATION REQUIREMENTS 1 3 6 7 22 26 10 9 8 12 11 14 13 15 16 17 18 28 29 25 37 32 31 30 27 38 39 2 34 35 36 33 5 4 20 19 21 24 23 # TYPE SIZE REQUIRED MITIGATION TREES 1 SILVER MAPLE 30" 3 2 SIBERIAN ELM 60" 0 3 SIBERIAN ELM 60" 0 4 SPRUCE 12" 1 5 CRABAPPLE 16" 2 6 SIBERIAN ELM 60" 0 7 SIBERIAN ELM 47" 0 8 JUNIPER 8" 1 9 JUNIPER 7" 1 10 CRABAPPLE 20" 0 11 ASH 10" 3 12 ASH 12" 3 13 SIBERIAN ELM 8" 0 14 SILVER MAPLE 25" 0 15 SIBERIAN ELM 46" 0 16 DOUGLAS FIR 8" 1 17 NORWAY MAPLE 19" 2 18 ASH 4" 0 19 SIBERIAN ELM 8" 0 20 SIBERIAN ELM 35" 0 21 HAWTHORN 6" 0 22 CRABAPPLE 17" 2 23 HONEYLOCUST 12" 2 24 ASH 8" 1 25 CRABAPPLE 12" 0 26 ASH 12" 3 27 SIBERIAN ELM 8" 0 28 COTTONWOOD 35" 5 29 ASH 16" 3 30 SIBERIAN ELM 8" 0 31 SIBERIAN ELM 12" 0 32 SIBERIAN ELM 8" 0 33 SIBERIAN ELM 6" 0 34 SILVER MAPLE 14" 2 35 CRABAPPLE 8" 1 36 SIBERIAN ELM 43" 0 37 SIBERIAN ELM 8" 0 38 HACKBERRY 7" 1 # TYPE SIZE REQUIRED MITIGATION TREES 39 SIBERIAN ELM 24" 0 40 GREEN ASH 23" 5 41 CRABAPPLE 19" 2 42 SIBERIAN ELM 12" 0 43 NORWAY MAPLE 12" 0 44 SIBERIAN ELM 18" 0 45 SIBERIAN ELM 8" 0 46 SIBERIAN ELM 6" 0 47 ASPEN 9" 1 48 SIBERIAN ELM 6" 0 49 SIBERIAN ELM 6" 0 50 SIBERIAN ELM 6" 0 51 WILLOW 6" 0 52 SIBERIAN ELM 6" 0 53 SIBERIAN ELM 8" 0 54 SIBERIAN ELM 12" 0 55 SIBERIAN ELM 10" 0 56 HONEYLOCUST 21" 5 57 HONEYLOCUST 30" 5 58 ASH 26" 6 59 ASH 7" 1 60 ASH 12" 0 61 SIBERIAN ELM 13" 0 62 SIBERIAN ELM 13" 0 63 SIBERIAN ELM 10" 0 64 HONEYLOCUST 32" 4 65 SPRUCE 10" 1 66 SIBERIAN ELM 13" 0 67 SIBERIAN ELM 24" 0 68 BOXELDER 7" 0 69 SIBERIAN ELM 6" 0 70 SIBERIAN ELM 6" 0 71 SIBERIAN ELM 6" 0 72 POPLAR 5" 0 73 RUSSIAN OLIVE 19" 0 74 JUNIPER 12" 1 75 HACKBERRY 10" 1 76 HONEYLOCUST 26" 0 40 41 42 43 45 44 46 47 48 49 50 51 52 54 55 56 57 58 53 78 77 59 59 60 61 63 62 65 64 67 66 68 69 70 71 72 76 75 73 74 # TYPE SIZE REQUIRED MITIGATION TREES 77 ASH 24" 4 78 ASH 27" 4 79 BOXELDER 34" 0 80 ASH 18" 4 81 COTTONWOOD 37" 5 82 BOXELDER 12" 0 83 BOXELDER 6" 0 84 SPRUCE 28" 5 85 CRABAPPLE 21" 1 86 CRABAPPLE 21" 1 87 JUNIPER 12" 1 88 SIBERIAN ELM 6" 0 89 CRABAPPLE 12" 1 90 JUNIPER 12" 1 91 HACKBERRY 10" 1 92 HACKBERRY 14" 1 93 CRABAPPLE 21" 0 94 HACKBERRY 18" 4 95 SIBERIAN ELM 26" 0 96 SIBERIAN ELM 13" 0 97 SIBERIAN ELM 24" 0 98 BOXELDER 6" 0 99 SIBERIAN ELM 8" 0 100 JUNIPER 12" 1 101 ASH 29" 4 102 RUSSIAN OLIVE 19" 0 103 SIBERIAN ELM 18" 0 104 ASH 18" 2 105 HONEYLOCUST 30" 4 106 SIBERIAN ELM 6" 0 107 SIBERIAN ELM 39" 0 108 SPRUCE 28" 0 109 WILLOW 60" 3 110 SIBERIAN ELM 8" 0 111 SILVER MAPLE 31" 3 112 CRABAPPLE 17" 2 113 CRABAPPLE 17" 0 114 SIBERIAN ELM 12" 0 79 80 81 82 94 89 93 88 87 85 86 84 92 91 83 90 97 96 95 98 99 100 101 102 103 127 128 126 130 110 108 109 104 105 107 106 111 112 113 114 125 124 123 121 120 115 116 119 117 118 122 129 # TYPE SIZE REQUIRED MITIGATION TREES 115 SIBERIAN ELM 12" 0 116 SIBERIAN ELM 12" 0 117 SIBERIAN ELM 12" 0 118 SPRUCE 24" 5 119 SIBERIAN ELM 12" 0 120 SIBERIAN ELM 12" 0 121 SIBERIAN ELM 12" 0 122 SPRUCE 13" 3 123 SIBERIAN ELM 12" 0 124 SIBERIAN ELM 12" 0 125 SIBERIAN ELM 39" 0 126 HONEYLOCUST 18" 4 127 SPRUCE 15" 2 128 SPRUCE 10" 2 129 SIBERIAN ELM 6" 0 130 JUNIPER 12" 1 1. EXISTING TREES MARKED FOR PROTECTION AND PRESERVATION SHALL NOT BE REMOVED. 2. HEAVY EQUIPMENT SHOULD NOT BE ALLOWED TO COMPACT OVER THE ROOT ZONE OF EXISTING TREES. 3. AVOID CUTTING SURFACE ROOTS WHENEVER POSSIBLE. SIDEWALKS AND PAVING LEVELS SHOULD BE CONTOURED SUFFICIENTLY TO AVOID DAMAGE. 4. ROOT CUTS FROM EXCAVATION SHOULD BE DONE RAPIDLY. SMOOTH FLUSH CUTS SHOULD BE MADE. BACKFILL BEFORE THE ROOTS HAVE A CHANCE TO DRY OUT AND WATER THE TREE IMMEDIATELY. 5. PRIOR TO CONSTRUCTION, ALL PROTECTED TREES SHALL HAVE ORANGE PROTECTION BARRIER FENCING ERECTED, WHICH AS A MINIMUM ARE SUPPORTED BY 1" X 1" OR SIMILAR STURDY STOCK, FOR SHIELDING OF PROTECTED TREES, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE HALF ( 1 2) OF THE DRIP LINE, WHICH EVER IS GREATER. WITHIN THIS PROTECTION ZONE THERE SHALL BE NO MOVEMENT OF EQUIPMENT OR STORAGE OF EQUIPMENT, MATERIALS, DEBRIS, FILL OR CUT UNLESS APPROVED BY THE CITY FORESTER. 6. ALL EXISTING TREES SHALL BE PRUNED TO THE CITY FORESTER'S "MEDIUM PRUNE STANDARDS. 7. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 8. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE OR DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE, WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 9. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 10. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BY "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN NOTE (5) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POSTS STAKES A MAXIMUM OF FIFTY FEET APART AND TYING A RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. TREE PROTECTION NOTES (R) TYPE COUNT REQUIRED MITIGATION TREES (P) = TREES BEING PRESERVED 10 0 (R) = TREES TO BE REMOVED 120 128 TOTAL 130 128 TREE MITIGATION SUMMARY (P) (P) (P) (P) (P) (P) (P) (P) (P) (P) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) LOCATION COUNT MITIGATION TREES PROPOSED TO BE PLANTED ON-SITE 128 MITIGATION TREES PROPOSED TO BE PLANTED OFF-SITE 0 TOTAL 128 PROVIDED TREE MITIGATION (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) 1. TREES TO BE PRESERVED ARE A CRITICAL SCREEN CLOSE TO THE BUILDING FOUNDATION. A QUALIFIED CERTIFIED PRIVATE ARBORIST WILL EVALUATE AND SUPERVISE EXCAVATION IN THE ROOT ZONE AND OTHER WORK IMPACTING THE TREES DURING CONSTRUCTION. DEPENDING ON THE AMOUNT OF ACTUAL ROOT CUTTING OR BRANCH PRUNING DETERMINED BY THE CERTIFIED ARBORIST TO HAVE OCCURRED RETENTION OF A TREE MAY NOT BE ADVISED. GENERAL NOTES