HomeMy WebLinkAboutTHE DISTRICT AT CAMPUS WEST - FDP - FDP120021 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLAN (3)GROSS
GROSS AREA 194,962 SF (4.48 AC)
TOTAL DWELLING UNITS 189
GROSS DENSITY 42.19 DU/AC
EXISTING ZONING CC
GROSS
AREA %
BUILDING COVERAGE 98,007 SF 50%
DRIVES AND PARKING
(EXCLUDES PUBLIC ROW) 2,222 SF 1%
OPEN SPACE AND LANDSCAPE
(EXCLUDES PUBLIC ROW) 20,075 SF 11%
HARDSCAPE
(EXCLUDES PUBLIC ROW) 23,736 SF 12%
*ACTIVE RECREATIONAL USE 1,572 SF 1%
**PUBLIC STREET RIGHT-OF-WAY 49,350 SF 25%
HARDSCAPE 9,111 SF
DRIVES AND PARKING 35,366 SF
LANDSCAPE 4,873 SF
TOTAL GROSS COVERAGE
194,962 SF
(4.48 AC) 100%
* POOL AND HOT TUB
** CALCULATED FROM RIGHT-OF-WAY (ROW) LINE TO CENTERLINE OF ADJACENT STREET
NET
NET AREA 145,612 SF (3.34 AC)
TOTAL DWELLING UNITS 189
NET DENSITY 56.60 DU/AC
DENSITY
AREA COVERAGE
NET
AREA %
BUILDING COVERAGE 98,007 SF 67%
DRIVES AND PARKING 2,222 SF 2%
OPEN SPACE AND LANDSCAPE 20,075 SF 14%
HARDSCAPE (WALKS & PLAZAS) 23,736 SF 16%
*ACTIVE RECREATIONAL USE 1,572 SF 1%
PUBLIC STREET RIGHT-OF-WAY 0 0%
TOTAL NET COVERAGE
145,612 SF
(3.34 AC) 100%
RIGHT-OF-WAY (ROW) TO BE VACATED
TYPE AREA
PLATTED ROW 8,307 SF
APPARENT ROW (DAISY AND COLUMBINE STREETS) 7,901 SF
TOTAL 16,208 SF
DWELLING UNIT BREAKDOWN
UNIT TYPE: DWELLING UNITS TOTAL BEDROOMS
TWO BEDROOM UNITS 28 (15%) 56
THREE BEDROOM UNITS 42 (22%) 126
FOUR BEDROOM UNITS 119 (63%) 476
TOTAL 189 (100%) 658
BICYCLE PARKING
PROVIDED REQUIRED *
BICYCLE SPACES 332 47
LOCATED IN GARAGE (BLDG 02) 296
LOCATED IN COURTYARDS 36
FLOOR AREA RATIO
LOT 1, BLOCK 1
BUILDING AREA 360,788 SF
LOT AREA 112,765 SF
FLOOR AREA RATIO (LOT 1, BLOCK 1) 3.20
LOT 1, BLOCK 2
BUILDING AREA 100,761 SF
LOT AREA 32,847 SF
FLOOR AREA RATIO (LOT 1, BLOCK 2) 3.07
HOUSING TYPES
MULTI-FAMILY (BLDG 03)
MIXED-USE (BLDG 01 AND 02)
* THE PROJECT IS LOCATED WITHIN THE TRANSIT-ORIENTED DEVELOPMENT (TOD) OVERLAY DISTRICT WHICH DOES
NOT REQUIRE PARKING.
BUILDING HEIGHT
MAXIMUM HEIGHT STORIES
BUILDING 01
TOWERS: 67'-1"
MAIN BLDG (5-STORY): 61'-1"
MAIN BLDG (4-STORY): 48'-8"
5 / 4
BUILDING 02
TOWERS: 57'-8"
MAIN BLDG: 41'-8"
GARAGE: 48'
4
BUILDING 03 TOWERS: 67'-1" MAIN BLDG: 61'-1" 5
* REQUIRED BICYCLE SPACES ARE CALCULATED AS 10% OF TOTAL PROJECT PARKING.
PROJECT PARKING
PROVIDED REQUIRED * REQUIRED IF NOT IN TOD
LONG-TERM PARKING 449 MIN. 0 422
GUEST SPACES 2 0 0
HANDICAP 10 9 9
TOTAL 461 MIN. 9 431
W. PLUM ST.
SUNSTONE CONDOMINIUMS
CAMBRIDGE HOUSE APARTMENTS
EXISTING SINGLE-FAMILY
PROPOSED ROW (TYP)
6.5' PARKWAY
6.5' PARKWAY
5'
6.5' PARKWAY
EXISTING COLUMBINE STREET
TO BE VACATED (HATCHED)
EXISTING DAISY STREET TO BE
VACATED (HATCHED)
25'
50'
ENHANCED TRANSIT STOP / PULL-IN
DISTINGUISHABLE DRIVE INTO PARKING GARAGE
COURT
YARD
ENTRY
ENTRY
ENTRY
ENTRY
TC
TC
8.5'
8.5'
ENTRY
PLAZA
5'
ENTRY ENTRY ENTRY
ENTRY
7'
ENTRY
ENTRY
7'
15'
DISTINGUISHABLE PEDESTRIAN WALK
TRANSIT WAITING AREA WITH BENCH
PLAZA WITH RETAINING WALL
AROUND EXISTING TREE
F
P
P P
P P
P
P
P P
P
P
P
P
50'
6.5' PARKWAY
FENCE WITH GATE
B B
B
FENCE WITH GATE
5'
8.5'
12.5'
8'
4'
40'
33'
4'
3.5'
4.5'
11'
10'
9.5'
8.5'
GARAGE
APARTMENT
UNITS
8'
8.5'
EXISTING ROW (TYP)
PROPOSED ROW (TYP)
EXISTING ROW (TYP)
7' WALK 7' WALK
7' WALK
7' WALK
EXISTING ROW
PROPOSED ROW
5'
7'
8.5'
8.5'
5'
40'
7'
5'
5'
6.5' PKWY
5'
7'
7' WALK
PEDESTRIAN
PLAZA
LAWN
7'
DRAINAGE DRAINAGE EASEMENT, RE: CIVIL
EASEMENT,
RE: CIVIL
DRAINAGE
EASEMENT,
RE: CIVIL
DRAINAGE
EASEMENT,
RE: CIVIL
UTILITY
EASEMENT,
RE: CIVIL
UTILITY
EASEMENT,
RE: CIVIL
P
B
B B
LIMITS OF DEVELOPMENT
LINE (TYP) LIMITS OF DEVELOPMENT
LINE (TYP)
METAL FENCE ALONG PROPERTY
LINE WHERE INDICATED. SEE
DETAIL A, THIS SHEET
9.5'
GUEST PARKING SPACES (2)
ENTRY
END OF
METAL
FENCE
END OF
METAL
FENCE
ZETA TAU ALPHA SORORITY
ENTRY
PLAZA
PAVING EXTENDS TO STREET
PAVING EXTENDS TO STREET
STEPS/SEATING
PLANTER / SHRUB BED
TURF
ENHANCED PAVING AREA (NOT AN
INDICATION OF SIZE OR PATTERN)
ENHANCED PAVING DRIVE (NOT AN
INDICATION OF SIZE OR PATTERN)
GAS FIRE FEATURE
PATIO (PRIVATE)
F
P
TC TRASH COMPACTOR (ENCLOSED IN BLDG)
B BIKE RACK AREA
EXISTING TREES TO REMAIN
TABLE
TREE GRATE
PLANTING POTS
H.T. HOT TUB
STREETLIGHT
METAL PICKET FENCE. DETAIL A, THIS SHEET
RIVER BOULDERS
LIMIT OF DEVELOPMENT LINE
SITE PLAN
SCALE ACCORDINGLY IF REDUCED
DRAWING NUMBER:
DEVELOPER / APPLICANT
FT. COLLINS STUDENT HOUSING, LLC
DEREK ANDERSON
1302 WAUGH DRIVE, #305
+2867217;
832.236.0400
SITE ENGINEER AND SURVEYOR
NORTHERN ENGINEERING
NICK HAWS, PE, LEED AP
200 S. COLLEGE AVE. SUITE 100
FORT COLLINS, CO 80524
970.221.4158
ARCHITECT
HUMPHREYS & PARTNERS ARCHITECTS, L.P.
YAO HUA YU, AIA, NCARB
5339 ALPHA ROAD, SUITE 300
DALLAS, TX 75240
972.701.9636
401 West Mountain Avenue Suite 100 Fort Collins, CO 80521
fax 970/224.1662 phone 970/224.5828 www.vfrdesigninc.com
Ŷ land planning Ŷ landscape architecture Ŷ
Ŷ urban design Ŷ entitlement Ŷ
FORT COLLINS, COLORADO
THE DISTRICT AT
CAMPUS WEST
FINAL COMPLIANCE
PLAN
IN ASSOCIATION WITH:
PROJECT No.: R11-021
DRAWN BY: BC
REVIEWED BY: LR
SEAL:
THIS IS A LAND USE PLANNING DOCUMENT,
NOT A CONSTRUCTION DOCUMENT. REFER
TO CIVIL ENGINEERING PLANS.
PDP-FINAL COMPLIANCE
OF 9
ISSUED
No. DESCRIPTION DATE
1 PDR 08.17.11
2 PDP 01.25.12
3 PDP-FINAL COMPLIANCE 12.05.12
REVISIONS
No. DESCRIPTION DATE
1 PDP RE-SUBMITTAL 02.29.12
2 REVISED FOR HEARING 03.26.12
3 MINOR AMENDMENT 10.19.12
TRAFFIC
ELB ENGINEERING, LLC.
ERIC L. BRACKE, P.E., P.T.O.E.
5401 TAYLOR LANE
FORT COLLINS, CO 80528
970.988.7551
GEOTECH
TERRACON
ERIC D. BERNHARDT, P.E.
301 NORTH HOWES STREET
)257&2//,16&2
970.484.0359
2
BUILDING AND SITE INFORMATION
LEGEND
SCALE: 1/2" = 1'-0"
A 6' SPEAR TOP ALUMINUM FENCE