Loading...
HomeMy WebLinkAboutENGINES & ENERGY CONVERSION LAB - BDR - BDR120006 - SUBMITTAL DOCUMENTS - ROUND 1 - RECOMMENDATION/REPORT4396 GREENFIELD DRIVE WINDSOR, COLORADO 80550 (970) 545-3908 FAX (970) 663-0282 November 14, 2011 Colorado State University Research Foundation 601 South Howes Street – Room 410 Fort Collins, Colorado 80521 Attn: Mr. Stuart MacMillan Re: Subsurface Exploration Report for Permeable Pavers - Addendum No. 2 Proposed 50,000 SF Multi-Tenant Office/Lab Addition and Pavement Areas Colorado State University (CSU) – Engines and Energy Conservation Lab 430 North College Avenue Fort Collins, Colorado EEC Project No. 1112015 Mr. MacMillan: Enclosed, herewith, are the results of the permeable paver subsurface exploration study completed by Earth Engineering Consultants, Inc. (EEC) personnel for proposed site improvements to the existing Colorado State University’s Engines and Energy Conservation Laboratory (EECL) facility located at 430 North College Avenue in Fort Collins, Colorado. For this study two (2) soil profile borings were drilled to approximate depths of 15-feet below existing site grades and a series of three (3) shallow soil percolation borings were drilled to approximate depths of 3-feet below existing site grades within an area planned for permeable pavers. This supplemental permeable paver evaluation/study was completed in general accordance with our proposal dated October 21, 2011. INTRODUCTION Permeable Pavers are a paving alternative to more traditional types of hard surfacing materials, where water is allowed to filter through the surface and into the underlying subsoils. Storm water brings with it pollutants, chemicals, fertilizers, sediment and oils, impacting the quality of water flowing into the various catchment areas. Permeable pavers permit rainwater to be absorbed by the ground underneath, while still managing to provide a stable enough surface for vehicles. Permeable Pavers preserve the quality of the water, and also increase the quantity of “good quality” water. Permeable Pavers can be made from many different types of materials. The design team is considering the use of permeable pavers as an alternative pavement method for portions of the CSU EECL on-site pavement improvement areas for possible LEED credits. At this point, the type or manufacturer of the permeable pavers has not yet been determined. The purpose of this study was to evaluate the subsurface soils to assist the design team in determining if permeable pavers are feasible for this project. CDN #2627A-027 Earth Engineering Consultants, Inc. CSU’s EECL – 430 North College Avenue Permeable Paver Evaluation Report November 14, 2011 EEC Project No. 1112015 Page 2 EXPLORATION AND TESTING PROCEDURES The permeable paver/soil percolation related boring locations were established in the field by a representative of Earth Engineering Consultants, Inc. (EEC) by pacing and estimating angles from identifiable site features. The area evaluated currently is a poriton of the existing asphalt paved parking lot which is identified as a “no-parking” zone, as shown on the enclosed site photographs. The approximate boring locations are indicated on the attached boring location diagram. The locations of the borings should be considerate accurate only to the degree implied by the methods used to make the field measurements. Due to the known presence of landfill debris and the possibility for asbestos containing materials (ACM), an environmental assessment was conducted concurrently with our initial geotechnical subsurface exploration in June of 2011, by Walsh Environmental Engineers and Scientists (Walsh). As part of the environmental related concerns, the site is under a “Soil Characterization Management Plan” (SCMP), and an environmental “soil-spotter” from National Inspection Services (NIS), (the environmental consulting firm representing CSURF), was on-site during the supplemental soil percolation exploration drilling operations. The soil percolation borings were performed using a truck-mounted, CME-75 drill rig equipped with a hydraulic head employed in drilling and sampling operations. The soil profile borings (P-1 and P-2), along with the shallow soil percolation borings (SP-1 through SP-3) were advanced using 4 and 6-inch diameter continuous flight augers respectively, and samples of the subsurface materials encountered were obtained using split-barrel sampling procedures in general accordance with ASTM Specifications D-1586. In the split barrel sampling procedure, a standard sampling spoon is driven into the ground by means of a 140-pound hammer falling a distance of 30 inches. The number of blows required to advance the sampler is recorded and is used to estimate the in-situ relative density of cohesionless soils and, to a lesser degree of accuracy, the consistency of cohesive soils. All samples obtained in the field were sealed and returned to the laboratory for further examination, classification and testing. Moisture content tests were completed on each of the recovered samples. As part of the testing program, all samples were examined in the laboratory by an engineer and classified in accordance with the attached General Notes and the Unified Soil Classification System, based on the soil’s texture and plasticity. The estimated group symbol for the Unified Soil Classification System is indicated on the boring logs and a brief description of that classification system is included with this report. CDN #2627A-027 Earth Engineering Consultants, Inc. CSU’s EECL – 430 North College Avenue Permeable Paver Evaluation Report November 14, 2011 EEC Project No. 1112015 Page 3 SUBSURFACE CONDITIONS An EEC field engineer was on site during the supplemental drilling operations to evaluate the subsurface conditions encountered and to direct the drilling activities. Field logs prepared by EEC’s site personnel were based on visual and tactual observation of auger cuttings and disturbed samples. A “soil-spotter” from NIS was also on-site during the subsurface exploration activities as required per the site-specific SCMP. The boring logs included with this report may contain modifications to the field logs based on results of laboratory testing and engineering evaluation. Based on results of the field boring and laboratory testing, subsurface conditions can be generalized as follows. At the surface of each permeable paver related soil boring, the existing pavement section generally consisted of approximately 2 to 2-1/2-inches of asphaltic concrete pavement underlain by approximately 6-inches of existing aggregate base course. In summary, the subsurface materials encountered beneath the surficial layers in the two (2) soil profile borings and each of the three (3) shallow soil percolation borings consisted of existing fill material and landfill debris, which extended to the depths explored, approximately 3 to 15-feet below existing site grades. Based on visual observations, it appeared the upper approximate 3-feet of material generally consisted of silty sand with gravel and/or clayey sand with gravel and intermittent cobbles. Below a depth of about 3-feet, the fill material generally consisted of clayey sand with gravel with intermittent evidence of landfill debris, which extended to the depths explored. In our previous subsurface exploration, (please refer to our report dated June 14, 2011), the native sand, gravel and intermittent cobble zone was encountered at depths of about 17 to 18-feet below site grades. Within a few of the split-spoon samples obtained at the 4, 9, and 14-foot intervals, and periodic auger cuttings, slight evidence of landfill debris consisting of cinders, wood, and construction debris were noted; other materials may be present and variations in depth may exist across the site. The stratification boundaries indicated on the boring logs represent the approximate locations of changes in soil; in-situ, the transition of materials may be gradual and indistinct. WATER LEVEL OBSERVATIONS Groundwater was not encountered in either of the soil profile borings drilled to maximum depths of 15-feet below site grades, or the shallow soil percolation borings, drilled to 3-feet below site grades. As requested, due to the environmental concerns, the two (2) soil profile borings were backfilled with bentonite upon completion of the drilling operations, and the three (3) shallow soil percolation CDN #2627A-027 Earth Engineering Consultants, Inc. CSU’s EECL – 430 North College Avenue Permeable Paver Evaluation Report November 14, 2011 EEC Project No. 1112015 Page 4 boreholes were also backfilled with bentonite the following day after performing the field percolation testing; therefore stabilized/subsequent groundwater measurements were not obtained. During our initial exploration conducted in June of 2011, groundwater was measured at depths of approximately 17 to 18-feet below site grades. Fluctuations in groundwater levels can occur over time depending on variations in hydrologic conditions and other conditions not apparent at the time of this report. In addition, zones of perched and/or trapped may be encountered at times throughout the year in more permeable areas within the subgrade materials. The location and amount of perched water can also vary over time depending on variations in hydrologic conditions and other conditions not apparent at the time of this report. ANALYSIS AND RECOMMENDATIONS Pavement Design Considerations – Permeable Pavers We understand design concepts for a permeable paver pavement section is currently being discussed for the site to achieve LEED credits and to reduce the amount of storm water runoff to detention areas. The following provides general design considerations for use with permeable pavers. The subgrade preparation recommendations provided in EEC’s “Surface Exploration Report” dated June 14, 2011, for conventional parking areas will need to be revised if a permeable paver pavement alternative is selected for the site. To assess the feasibility for use of permeable pavers on site, EEC personnel conducted preliminary infiltration characteristics by running “soil percolation” characteristics, similar to that used for developing design criteria for an on-site sewage disposal system. The subsoils analyzed within the proposed permeable paver pavement section on site, (i.e., the general vicinity of soil profile borings P-1 and P-2), consisted of a granular silty sand with gravel and intermittent cobble fill zone to depths of about 3-feet below site grades with the presence of intermittent landfill debris/materials below. The landfill debris/materials extended to the maximum depths of exploration, approximately 15-feet. The upper granular fill materials exhibited soil percolation characteristics on the order of about 5 to 15 minutes per inch, which correlates to about 4 to 12-inches per hour. According to various pervious/permeable paving documents, “as a general rule, soils with a percolation rate of ½ to 1 inch/hour are suitable for subgrade under pervious/permeable pavements.” Although not specifically encountered/observed during our subsurface exploration phase, clay soils and/or other impermeable layers, which may exist at other locations, can hinder the performance of pervious/permeable pavements and may need to be modified to allow proper retention and percolation of precipitation. Design concepts to consider for accommodating the presence of CDN #2627A-027 CDN #2627A-027 DRILLING AND EXPLORATION DRILLING & SAMPLING SYMBOLS: SS: Split Spoon - 13/8" I.D., 2" O.D., unless otherwise noted PS: Piston Sample ST: Thin-Walled Tube - 2" O.D., unless otherwise noted WS: Wash Sample R: Ring Barrel Sampler - 2.42" I.D., 3" O.D. unless otherwise noted PA: Power Auger FT: Fish Tail Bit HA: Hand Auger RB: Rock Bit DB: Diamond Bit = 4", N, B BS: Bulk Sample AS: Auger Sample PM: Pressure Meter HS: Hollow Stem Auger WB: Wash Bore Standard "N" Penetration: Blows per foot of a 140 pound hammer falling 30 inches on a 2-inch O.D. split spoon, except where noted. WATER LEVEL MEASUREMENT SYMBOLS: WL : Water Level WS : While Sampling WCI: Wet Cave in WD : While Drilling DCI: Dry Cave in BCR: Before Casing Removal AB : After Boring ACR: After Casting Removal Water levels indicated on the boring logs are the levels measured in the borings at the time indicated. In pervious soils, the indicated levels may reflect the location of ground water. In low permeability soils, the accurate determination of ground water levels is not possible with only short term observations. DESCRIPTIVE SOIL CLASSIFICATION Soil Classification is based on the Unified Soil Classification system and the ASTM Designations D-2488. Coarse Grained Soils have move than 50% of their dry weight retained on a #200 sieve; they are described as: boulders, cobbles, gravel or sand. Fine Grained Soils have less than 50% of their dry weight retained on a #200 sieve; they are described as : clays, if they are plastic, and silts if they are slightly plastic or non-plastic. Major constituents may be added as modifiers and minor constituents may be added according to the relative proportions based on grain size. In addition to gradation, coarse grained soils are defined on the basis of their relative in-place density and fine grained soils on the basis of their consistency. Example: Lean clay with sand, trace gravel, stiff (CL); silty sand, trace gravel, medium dense (SM). CONSISTENCY OF FINE-GRAINED SOILS Unconfined Compressive Strength, Qu, psf Consistency < 500 Very Soft 500 - 1,000 Soft 1,001 - 2,000 Medium 2,001 - 4,000 Stiff 4,001 - 8,000 Very Stiff 8,001 - 16,000 Very Hard RELATIVE DENSITY OF COARSE-GRAINED SOILS: N-Blows/ft Relative Density 0-3 Very Loose 4-9 Loose 10-29 Medium Dense 30-49 Dense 50-80 Very Dense 80 + Extremely Dense PHYSICAL PROPERTIES OF BEDROCK DEGREE OF WEATHERING: Slight Slight decomposition of parent material on joints. May be color change. Moderate Some decomposition and color change throughout. High Rock highly decomposed, may be extremely broken. HARDNESS AND DEGREE OF CEMENTATION: CDN #2627A-027 CSU EEC – PERMEABLE PAVER FIELD EXPLORATION 430 NORTH COLLEGE AVENUE – FORT COLLINS, COLORADO EEC PROJECT NO. 1112015 NOVEMBER 2011 CDN #2627A-027 CDN #2627A-027 CDN #2627A-027 DATE: RIG TYPE: CME 75 FOREMAN: DAR AUGER TYPE: 4-1/4" Inside Dia. HSA SPT HAMMER: MANUAL SOIL DESCRIPTION D N QU MC DD -200 TYPE (FEET) (BLOWS/6 IN) (PSF) (%) (PCF) LL PI (%) PRESSURE % @ 500 PSF EXISTING HMA PAVEMENT: Approx. 2 - 2-1/2" _ _ EXISTING ABC: Approx. 6 to 8" 1 FILL MATERIAL: Silty Sand with Gravel and/or _ _ Clayey Sand with Gravel and Cobbles 2 _ _ 3 LANDFILL DEBRIS encountered below 3.0' _ _ loose unconsolidated material, evidence of 4 wood, cinders, and miscellaneous _ _ 3 construction/landfill debris encountered 5 2 2000 18.1 within CLAYEY SAND with GRAVEL fill material _ _ 4 6 _ _ 7 _ _ 8 _ _ 9 _ _ 4 *Evidence of FILL MATERIAL at 9-feet SS 10 6 -- 31.3 cinders were noted within the SS Sample @ 9-feet _ _ 8 11 _ _ 12 _ _ 13 _ _ 14 _ _ 3 *Evidence of wood debris at 14-feet 15 2 -- 33.5 _ _ 3 BOTTOM OF PROFILE BORING @ 15.5' 16 _ _ 17 _ _ 18 _ _ 19 _ _ 20 _ _ 21 _ _ 22 _ _ 23 _ _ 24 _ _ 25 _ _ Earth Engineering Consultants SS DATE: RIG TYPE: CME 75 FOREMAN: DAR AUGER TYPE: 4-1/4" Inside Dia. HSA SPT HAMMER: MANUAL SOIL DESCRIPTION D N QU MC DD -200 TYPE (FEET) (BLOWS/6 IN) (PSF) (%) (PCF) LL PI (%) PRESSURE % @ 500 PSF EXISTING HMA PAVEMENT: Approx. 2 - 2-1/2" _ _ EXISTING ABC: Approx. 6 to 8" 1 FILL MATERIAL: Silty Sand with Gravel and/or _ _ Clayey Sand with Gravel and Cobbles 2 _ _ 3 LANDFILL DEBRIS encountered below 3.0' _ _ loose unconsolidated material, evidence of 4 wood, cinders, and miscellaneous _ _ 3 construction/landfill debris encountered 5 7 -- 22.5 within CLAYEY SAND with GRAVEL fill material _ _ 11 6 _ _ 7 _ _ 8 _ _ 9 _ _ 2 *Evidence of loose FILL MATERIAL @ 9' SS 10 1 -- 52.5 cinders were noted within the SS Sample @ 9-feet _ _ 2 organics present indicating high moisture contents 11 _ _ 12 _ _ 13 _ _ 14 _ _ 3 *Evidence of wood debris at 14-feet 15 2 -- 28.1 _ _ 6 BOTTOM OF PROFILE BORING @ 15.5' 16 _ _ 17 _ _ 18 _ _ 19 _ _ 20 _ _ 21 _ _ 22 _ _ 23 _ _ 24 _ _ 25 _ _ Earth Engineering Consultants COLORADO STATE UNIVERSITY (CSU) - ENGINES AND ENERGY CONSERVATION LAB (EECL) 430 NORTH COLLEGE AVENUE - FORT COLLINS, COLORADO PROJECT NO: 1112015 NOVEMBER 2011 LOG OF PROFILE BORING P-2 SHEET 1 OF 1 WATER DEPTH START DATE 11/9/2011 WHILE DRILLING N/A to 15' FINISH DATE 11/9/2011 AFTER DRILLING Not Reported APPROX. SURFACE ELEV Not Reported 24 HOUR Backfilled SS A-LIMITS SWELL A-LIMITS SWELL APPROX. SURFACE ELEV Not Reported 24 HOUR Backfilled FINISH DATE 11/9/2011 AFTER DRILLING Not Reported SHEET 1 OF 1 WATER DEPTH START DATE 11/9/2011 WHILE DRILLING N/A to 15' LOG OF PROFILE BORING P-1 430 NORTH COLLEGE AVENUE - FORT COLLINS, COLORADO COLORADO STATE UNIVERSITY (CSU) - ENGINES AND ENERGY CONSERVATION LAB (EECL) PROJECT NO: 1112015 NOVEMBER 2011 Limestone and Dolomite: Hard Difficult to scratch with knife. Moderately Can be scratched easily with knife. Hard Cannot be scratched with fingernail. Soft Can be scratched with fingernail. Shale, Siltstone and Claystone: Hard Can be scratched easily with knife, cannot be scratched with fingernail. Moderately Can be scratched with fingernail. Hard Soft Can be easily dented but not molded with fingers. Sandstone and Conglomerate: Well Capable of scratching a knife blade. Cemented Cemented Can be scratched with knife. Poorly Can be broken apart easily with fingers. Cemented CDN #2627A-027