HomeMy WebLinkAboutREMINGTON ANNEX - PDP - PDP110017 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLAN (3)140' - 0"
CONNECTION TO SOUTH
COLLEGE AVENUE
THROUGH ADJACENT
PARKING GARAGE
REMINGTON STREET
EXISTING SIDEWALK
EXISTING SIDEWALK
EXISTING 1-STORY
RETAIL BUILDINGS
EXISTING COLLEGIO
3-STORY MIXED
USE BUILDING
EXISTING 3-STORY
RESIDENTIAL BUILDING
(701 REMINGTON)
CONNECTION TO EAST PLUM STREET ALLEY CONNECTION TO EAST LAUREL STREET
LOT 1
19,897 SQ.FT
0.457 ACRES
PRIMARY BUILDING ENTRANCE
WATER QUALITY POND.
REFER TO CIVIL SHEET
DR01
DETENTION & WATER
QUALITY POND. REFER
TO CIVIL SHEET DR01
SEAT WALL
WATER QUALITY
POND. REFER TO
CIVIL SHEET DR01
SOUTH EXIT DOOR
NORTH EXIT DOOR
EXIT FROM GARAGE
TRASH & RECYCLING
ENCLOSURE
PARKING GARAGE
ENTRY AND EXIT
TRANSFORMER AND
ELECTRIC METERS
5' - 3 1/2"
15' - 0"
OPEN TO
BELOW
TRANSFORMER
METERS
TRASH
RECYCLING
BRIDGE TO SECOND FLOOR
COURTYARD ABOVE
LEVEL PARKING
RAMP TO LOWER
39 PARKING SPACES
ON LOWER LEVELS
131' - 10 1/4"
5' - 1" 119' - 10"
5' - 1" 5' - 1"
100' - 0" EQUALS 4992.5' ON
99' - 6" CIVIL DRAWINGS
6.5%
6.5%
6.5%
41 43
40 42
45 46 47 48
44
63 61 59 58 57 56
49
50
51
52
53
62 60
65
64
104' - 8" 102' - 11"
EXISTING RESIDENCE
(719 REMINGTON)
WATER SERVICE,
REFER TO CIVIL
DRAWINGS
SANITARY SERVICE, REFER
TO CIVIL DRAWINGS
REFER TO LANDSCAPE
DRAWINGS FOR EXISITNG & NEW
TREES AND SHRUBS.
REFER TO LANDSCAPE
DRAWINGS FOR EXISITNG & NEW
TREES AND SHRUBS.
EXISTING FENCE
DEVELOPMENT PLANNING NOTES
MAXIIIMO DEVELOPMENT GROUP LLC IS PROPOSING A MULTI-UNIT HOUSING
PROJECT CALLED THE REMINGTON ANNEX, LOCATED AT THE COMBINED
PROPERTY ADDRESSES OF 705, 711 AND 715 ON REMINGTON STREET.
THIS HOUSING PROJECT WILL PROVIDE 42 UNITS OF MUCH NEEDED,
SUSTAINABLE HOUSING WITHIN WALKING AND BIKING DISTANCE OF THE CSU
CAMPUS AND DOWNTOWN FORT COLLINS. THE UNIT MIX CONSISTS OF 30
STUDIO UNITS, 8 ONE BEDROOMS, AND 4 TWO BEDROOMS. THE
DEVELOPMENT INCLUDES AN ONSITE ALLEY-ACCESSED PARKING
STRUCTURE CONTAINING 65 SPACES TO ACCOMMODATE THE INCREASE IN
PARKING NEEDS.
THE DESIGN INTENT OF THE REMINGTON ANNEX IS TO CREATE A FRONT
ELEVATION REPLICATING THREE SEPARATE AND MAJESTIC HOMES THAT
ARE TWO-STORY IN CHARACTER AND FEEL. THIS PROJECT
INCORPORATES STEEPER ROOF PITCHES ALLOWING FOR A DORMER
LEVEL WHICH PROVIDES NATURAL LIGHT TO A LIMITED NUMBER OF UPPER
FLOOR UNITS. THE MASSING OF THE THREE FACADES WILL REPLICATE
INDIVIDUAL RESIDENCES, INSPIRED BY ARCHITECTURAL DETAILS FROM
WITHIN THE NEIGHBORHOOD. OUR DESIGN DETAILS BOAST GENEROUS
FRONT PORCHES, VOLUMINOUS COLUMNS SUPPORTING ONE-STORY
ROOFS, ARCHED AND PANED WINDOWS AND DOORS, BRICK AND STONE
DETAILING AND LANDSCAPING THAT SUGGESTS, AND AGAIN, REPEATS THE
PATTERN OF THE STREET. PRIMARY ENTRANCES ARE LOCATED ALONG
REMINGTON STREET AT THE PORCH LOCATIONS. AS SUGGESTED BY THE
LAND USE CODE, “THE NEW DEVELOPMENT SHALL SET AN ENHANCED
STANDARD OF QUALITY FOR FUTURE PROJECTS OR REDEVELOPMENT IN
THE AREA.” THE CURRENT ARCHITECTURAL VARIETY OF REMINGTON
STREET IS A MIX OF SMALL COTTAGES, 2 ½ STORY TRIP-PLEXES, FOUR-
PLEXES AND LARGER 3-STORY APARTMENT BUILDINGS. AN INDEPENDENT
STUDY CONDUCTED BY OUR RESEARCH DEPARTMENT INDICATES THAT
81% OF THE STRUCTURES ON REMINGTON ARE OWNED BY INVESTORS
AND LEASED FOR THE PURPOSES OF RESIDENTIAL OR PROFESSIONAL
USE. OUR DESIGN TEAM SUBMITS THAT NOT ONLY WILL THE ARCHITECTURE
OF THE REMINGTON ANNEX SEEK TO MAINTAIN THE SCOPE AND
HISTORICAL INTEGRITY OF THE STREET THROUGH THE USE OF QUALITY
MATERIALS AND RELEVANT DESIGN DETAILS BUT ALSO THE PROJECT
WILL SEEK TO GREATLY ENHANCE THE STANDARDS OF SAFETY AND
SUSTAINABILITY.
IN ANTICIPATION OF THE NEED FOR HIGHER DENSITIES IN PROXIMITY TO
DOWNTOWN AND CSU, THE CITY’S LAND USE CODE IDENTIFIES COMPACT
URBAN GROWTH IN DIVISION 3.7 WHERE INFILL DEVELOPMENT IS
STRONGLY ENCOURAGED. THE REMINGTON ANNEX PROVIDES FOR A
MORE EFFICIENT USE OF EXISTING INFRASTRUCTURE, IMPROVES TRAFFIC
PATTERNS IN THE IMMEDIATE AREA, PROVIDES MUCH NEEDED PARKING
AND DUE TO ITS CENTRAL LOCATION PROVIDES EASY ACCESS TO
ALTERNATIVE TRANSPORTATION. THE DENSITY OF THE REMINGTON ANNEX
BRINGS RESIDENTS CLOSER TO AMENITIES THEREBY REDUCING VEHICLE
EMISSIONS AND CONGESTION BY REDUCING VEHICLE TRIPS PER DAY. THE
REMINGTON ANNEX CONCEPT IS WELL WITHIN THE CONTEXT OF THE NCB
DISTRICT WHICH PROVIDES ZONING FOR REDEVELOPMENT IN AREAS THAT
ARE A TRANSITION BETWEEN RESIDENTIAL NEIGHBORHOODS AND MORE
INTENSIVE COMMERCIAL USE AREAS OR HIGH TRAFFIC ZONES, IN THIS
CASE THE ALLEY. THE EAST SIDE OF REMINGTON IS A TOTALLY
DIFFERENT ZONING DISTRICT OF NCM WHICH ONLY ALLOWS 2 STORY
BUILDINGS WITH A MAXIMUM DENSITY OF 4 UNITS PER ACRE. THE CITY
ANTICIPATED THE NEED FOR THIS TYPE OF DEVELOPMENT WHEN THEY
CREATED THE TWO DIFFERENT ZONING DISTRICTS, ONE TO
ACCOMMODATE HIGHER DENSITY AND PROVIDE A TRANSITION AND THE
OTHER TO PRESERVE, MAINTAIN LOWER DENSITIES AND REFLECT THE
HISTORIC CHARACTER OF THE NEIGHBORHOOD. REMINGTON ANNEX
INCORPORATES ALL OF THESE DESIGN TECHNIQUES; INCLUDING
VARIATION OF ROOF LINES, USE OF SIMILAR PROPORTIONS IN BUILDING
MASS, SIMILAR WINDOWS AND DOOR PATTERNS AND THE USE OF
BUILDING MATERIALS SUCH AS BRICK, STONE, AND WOOD FRAMING IN
ORDER TO ACHIEVE NEIGHBORHOOD COMPATIBILITY.
THE REMINGTON ANNEX IS A NECESSARY AND CODE SANCTIONED
ADDITION TO REMINGTON STREET. THE DESIGN ELEMENTS HAVE
EVOLVED, WITH THE COLLABORATION OF THE COMMUNITY, CITY STAFF
AND OUR HIGHLY QUALIFIED DESIGN TEAM, INTO A PRIME EXAMPLE OF AN
ENHANCED EXAMPLE OF A REDEVELOPMENT IN AN NCB ZONE. THE
FINISHED PROJECT WILL NOT ONLY SERVE THE EXISTING CODE BY
PROVIDING MUCH NEEDED HOUSING IN A TRANSITIONAL AREA BUT WILL
ALSO SEEK TO PRESERVE AND ENHANCE THE STANDARDS OF QUALITY
FOR FUTURE PROJECTS OR REDEVELOPMENTS IN THE AREA.
GENERAL SITE NOTES
THE PARCEL IS ZONED NCB IN THE NEIGHBORHOOD
CONSERVATION, BUFFER DISTRICT
THE 3 STORY MULTI-UNIT RESIDENTIAL PROJECT IS SUBJECT TO A
TYPE-II REVIEW.
THE CONTRACTOR SHALL PREVIEW CONDITIONS AND REVIEW THE
GEOTECHNICAL ENGINEERING REPORT FOR REMINGTON ANNEX
VERIFY LOCATION ON EXISTING UTILITIES BEFORE PROCEEDING
WITH EXCAVATIONS.
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
MAINTAIN ADEQUATE DRAINAGE THROUGHOUT THE SITE DURING
THE PROCESS OF EXCAVATION AND GRADING. THE GRADE SHALL
BE MAINTAINED IN SUCH CONDITION THAT IT IS WELL DRAINED AT
ALL TIMES.
ADJACENT STREETS AND PARKING AREA SHALL BE KEPT FREE
OF MUD & DEBRIS. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR REMOVAL OF MUD AND DEBRIS AT THE END OF EACH DAY.
THE CONTRACTOR SHALL CONFINE STAGING, STORAGE AND
CONSTRUCTION PARKING TO THE AREA INDICATED.
THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS TO
REMAIN FROM DAMAGE. DAMAGED ITEMS SHALL BE REPLACED,
REPAIRED OR RESTORED BY CONTRACTOR AT NO COST TO THE
OWNER. IF, IN THE OPINION OF THE CONTRACTOR, EXISTING
IMPROVEMENTS TO REMAIN WILL BE DAMAGED OR REQUIRE
REMOVAL TO ACCOMPLISH CONSTRUCTION, CONTRACTOR SHALL
INCLUDE THE COST OF REPAIR OR REPLACEMENT IN BASE BID.
ALL IMPROVEMENTS ON PUBLIC PROPERTY SHALL CONFORM
WITH CITY OF FORT COLLINS RULES, REGULATIONS AND
ORDINANCES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
DWELLING UNIT SUMMARY
STUDIO APARTMENTS 30 1-BED 66 per ACRE
ONE-BEDROOM UNITS 8 1-BED 18 per ACRE
TWO-BEDROOM UNITS 4 2-BEDS 9 per ACRE
# OF
TYPE OF UNIT UNITS
# OF
BEDS/UNIT
UNIT TYPE
DENSITY
TOTAL UNITS
42
TOTAL BEDS
46
OVERALL RESIDENTIAL DENSITY
92 UNITS per ACRE
LAND USE BREAKDOWN
EXISTING SITE AREA TOTAL
EXISTING ROOF COVERAGE
EXISTING DRIVES & WALKWAY
EXISTING LANDSCAPE
PROPOSED SITE AREA TOTAL
PROPOSED ROOF COVERAGE
PROPOSED DRIVES & WALKWAY
PROPOSED LANDSCAPE
REQUIRED PARKING
PROPOSED PARKING
MAXIMUM HEIGHT
TOTAL RESIDENTIAL UNITS
(0.457 ACRES)
(0.457 ACRES)
64 SPACES
65 SPACES
3 STORIES
42 UNITS
19,897 SQ FT
5,576 SQ FT
3,637 SQ FT
10,682 SQ FT
19,897 SQ FT
14,862 SQ FT
2,139 SQ FT
2,893 SQ FT
401 West Mountain Avenue, Suite 100 Fort Collins, CO 80521
ph: 970.224.1191 www.theartofconstruction.com
DRAWING NUMBER:
PROJECT NUMBER:
SEAL:
IN ASSOCIATION WITH:
Strength in design. Strength in partnership.
Strength in community.
VAUGHT FRYE LARSON ARCHITECTS, INC. 2011.
THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR
COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA.
CHECKED BY:
DRAWN BY:
COPYRIGHT:
Issued
No. Description Date
1 (09-14-2011)
Revisions
LPC SUBMITTAL
2
3
4
5
6
7
8
9
10
No. Description Date
3
2
1
VAUGHT FRYE LARSON architects
RJH
JCL
LPC SUPPLEMENTAL SUBMITTAL (10-02-2011)
PDP SUBMITTAL (12-07-2011)
705-715 REMINGTON STREET
12/14/2011 11:32:44 AM
PDP-2
SITE PLAN
REMINGTON
ANNEX
DESIGN DEVELOPMENT
2011-47
PDP-2 1" = 10'-0"
1 SITE PLAN
NORTH
BUILDING FLOOR AREA BY USE
LOWER GARAGE 10649 SF
1st FLOOR GARAGE 10830 SF
1st FLOOR RESIDENTIAL 3468 SF
2nd FLOOR RESIDENTIAL 13262 SF
3rd FLOOR RESIDENTIAL 10410 SF
RESIDENTIAL TOTAL
PARKING GARAGE TOTAL
BUILDING TOTAL
27,146 SF
21,486 SF
48,632 SF
RESIDENTIAL FLOOR to LOT RATIO
PARKING GARAGE FLOOR to LOT RATIO
TOTAL BUILDING FLOOR to LOT RATIO
1.36
1.08
2.44