HomeMy WebLinkAboutWEST RANGE FORT COLLINS - PDP - PDP120028 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLAN (3)WEST LAUREL STREET
SOUTH MELDRUM STREET
WEST RANGE
FORT COLLINS
2-STORY
EXISTING STREET
TREES TO REMAIN
TREE INVENTORY &
MITIGATION PLAN
4
SEE LANDSCAPE PLAN, SHEET 3, FOR MITIGATION TREE LOCATIONS
TREE INVENTORY AND MITIGATION REQUIREMENTS
# TYPE SIZE CONDITION REQUIRED
MITIGATION TREES
1 APPLE 26" POOR 0
2 GREEN ASH 13" FAIR 1
3 HACKBERRY 17" FAIR 1.5
4 HACKBERRY 31" 2
5 SILVER MAPLE 17" FAIR-GOOD 2
6 BOXELDER 12" FAIR 1
7 AUSTRIAN PINE 30" FAIR-GOOD 4
8 GREEN ASH 11" POOR 0
9 GREEN ASH 7" POOR 0
10 HACKBERRY 16" FAIR-GOOD 2.5
11 HACKBERRY 13" FAIR 1.5
12 GREEN ASH 21" FAIR 3.5
13 HACKBERRY 17" FAIR-POOR 2
14 GREEN ASH 13" FAIR-POOR 1
15 GREEN ASH 17" FAIR-POOR 2
16 ELM 15" POOR 1
17 GREEN ASH 16" FAIR-GOOD 2
18 HACKBERRY 17" FAIR-GOOD 3
4
1. EXISTING TREES MARKED FOR PROTECTION AND PRESERVATION SHALL NOT BE REMOVED.
2. HEAVY EQUIPMENT SHOULD NOT BE ALLOWED TO COMPACT OVER THE ROOT ZONE OF EXISTING TREES.
3. AVOID CUTTING SURFACE ROOTS WHENEVER POSSIBLE. SIDEWALKS AND PAVING LEVELS SHOULD BE CONTOURED SUFFICIENTLY TO AVOID
DAMAGE.
4. ROOT CUTS FROM EXCAVATION SHOULD BE DONE RAPIDLY. SMOOTH FLUSH CUTS SHOULD BE MADE. BACKFILL BEFORE THE ROOTS HAVE A
CHANCE TO DRY OUT AND WATER THE TREE IMMEDIATELY.
5. PRIOR TO CONSTRUCTION, ALL PROTECTED TREES SHALL HAVE ORANGE PROTECTION BARRIER FENCING ERECTED, WHICH AS A MINIMUM ARE
SUPPORTED BY 1" X 1" OR SIMILAR STURDY STOCK, FOR SHIELDING OF PROTECTED TREES, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR
ONE HALF (1
2) OF THE DRIP LINE, WHICH EVER IS GREATER. WITHIN THIS PROTECTION ZONE THERE SHALL BE NO MOVEMENT OF EQUIPMENT OR
STORAGE OF EQUIPMENT, MATERIALS, DEBRIS, FILL OR CUT UNLESS APPROVED BY THE CITY FORESTER.
6. ALL EXISTING TREES SHALL BE PRUNED TO THE CITY FORESTER'S "MEDIUM PRUNE STANDARDS.
7. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED
ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE.
8. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE
STORAGE OR DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL
HARMFUL TO THE LIFE OF A TREE, WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.
9. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.
10. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD
RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BY "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS
REQUIRED IN NOTE (5) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POSTS STAKES A MAXIMUM OF FIFTY FEET APART AND TYING A
RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED.
TREE PROTECTION NOTES
(R)
TYPE COUNT REQUIRED
MITIGATION TREES
(P) = TREES BEING PRESERVED 3 0
(R) = TREES TO BE REMOVED 15 21
TOTAL 18 21
TREE MITIGATION SUMMARY
(R)
(R)
(R)
(R)
(P)
(R)
(R)
(R)
(R)
(P)
(P)
LOCATION COUNT
MITIGATION TREES PROPOSED TO BE PLANTED
ON-SITE 21
MITIGATION TREES PROPOSED TO BE PLANTED
OFF-SITE 0
TOTAL 21
PROVIDED TREE MITIGATION
(R)
(R)
(R)
(R)
1. TREES TO BE PRESERVED ARE A CRITICAL SCREEN CLOSE TO THE BUILDING FOUNDATION. A QUALIFIED CERTIFIED PRIVATE ARBORIST WILL EVALUATE AND
SUPERVISE EXCAVATION IN THE ROOT ZONE AND OTHER WORK IMPACTING THE TREES DURING CONSTRUCTION. DEPENDING ON THE AMOUNT OF ACTUAL ROOT
CUTTING OR BRANCH PRUNING DETERMINED BY THE CERTIFIED ARBORIST TO HAVE OCCURRED RETENTION OF A TREE MAY NOT BE ADVISED.
1
2
3
5
6
7
17
16
18
8 9
10 11
12
15
(R) 13 14
(R)
TREE PROTECTION NOTES
DEVELOPER / APPLICANT
WEST RANGE FORT COLLINS, LLC
BRANDON GREBE
5232 SOUTHERN CROSS LANE
FORT COLLINS, CO 80528
970.556.9111
SITE ENGINEER AND SURVEYOR
NORTHERN ENGINEERING
NICK HAWS, PE, LEED AP
200 S. COLLEGE AVE. SUITE 100
FORT COLLINS, CO 80524
970.221.4158
ARCHITECT
VFLA
JUSTIN LARSON
401 W. MOUNTAIN AVE., SUITE 100
FORT COLLINS, CO
970.224.1191
401 West Mountain Avenue Suite 100 Fort Collins, CO 80521
fax 970.224.1662 phone 970.224.5828 www.ripleydesigninc.com
Ŷ land planning Ŷ landscape architecture Ŷ
Ŷ urban design Ŷ entitlement Ŷ
FORT COLLINS, COLORADO
WEST RANGE
FORT COLLINS
IN ASSOCIATION WITH:
PROJECT No.: R12-036
DRAWN BY: RDI
REVIEWED BY: RDI
SEAL:
THIS IS A LAND USE PLANNING DOCUMENT,
NOT A CONSTRUCTION DOCUMENT. REFER
TO CIVIL ENGINEERING PLANS.
PDP
OF 8
ISSUED
No. DESCRIPTION DATE
1 PDR 10.04.11
2 PDP 10.24.12
REVISIONS
No. DESCRIPTION DATE
TRAFFIC
DELICH ASSOCIATES
MATT DELICH
2272 GLEN HAVEN DRIVE
LOVELAND, CO 80538
970.669.5034
SCALE ACCORDINGLY IF REDUCED
DRAWING NUMBER: