HomeMy WebLinkAboutELIZABETH & CITY PARK CORNER REDEVELOPMENT - PDP - PDP120008 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONSFinished Floor
100' - 0"
Roof Peak
129' - 0"
Finished Floor
100' - 0" (5035.2)
Top of Parapet
120' - 0"
BFE (5033.7)
Base Flood Elevation
RFPE (5035.2 ft)
Regulatory Flood
Protection Elevation
1' - 6"
Standing Seam Metal Roof
Prefinished Red
Steel Kicker
Painted to match Stucco
Light Fixture
Full cutoff exterior light fixture
Steel Canopy
Painted Red to match metal roof
Steel Screen Wall
Painted Charcoal Grey to match metal siding
Metal Panel
Prefinished Charcoal Grey
CMU Block Veneer
Brown Smooth Face Block
Concrete Curb
Integral curb - edge protection
CMU Block Veneer
Brown Smooth Face Block
Precast Concrete
Light Tan Precast sill
Steel Canopy
Painted Red to match metal roof
Steel Guardrail/Handrail
Steel tube railing painted Black
Aluminum Storefront
Prefinished Black, Typ.
29' - 0"
Metal Cap Flashing
Prefinished Charcoal Grey
Steel Canopy
Painted Red to match metal roof
Step Light
Full Cut-off, Typical
Architectural Light
Accent Fixture
Step Light
Full Cut-off, Typical
Metal Cap Flashing
Prefinished Sierra Tan
CMU Block Veneer
Brown Smooth Face Block
Steel Canopy
Painted Red to match metal roof
Aluminum Storefront
Prefinished Black, Typ.
Finished Floor
100' - 0"
Top of Parapet
120' - 0"
Top of Parapet
117' - 9"
Metal Panel
Prefinished Charcoal Grey
CMU Block Veneer
Brown Smooth Face Block
Aluminum Storefront
Prefinished Black, Typ.
Metal Cap Flashing
Prefinished Charcoal Grey
Steel Canopy
Painted Red to match metal roof
Transformer
New Electrical Transformer
Step Light
Full Cut-off, Typical
Finished Floor
100' - 0"
Roof Peak
129' - 0"
Sidewalk
96' - 6"
Finished Floor
100' - 0"
Top of Parapet
120' - 0"
Standing Seam Metal Roof
Prefinished Red
Steel Kicker
Painted to match Stucco
Steel Screen Wall
Painted Charcoal Grey to
match metal siding
CMU Block Veneer
Brown Smooth Face Block
Precast Concrete
Light Tan Precast sill
Steel Canopy
Painted Red to match
metal roof
29' - 0"
Steel Canopy
Painted Red to match
metal roof
Aluminum Storefront
Prefinished Black, Typ.
Metal Cap Flashing
Prefinished Brown
Utility Easement
Refer to Civil
Step Light
Full Cut-off, Typical
Architectural Light
Accent Fixture
Metal Panel
Prefinished Charcoal Grey
CMU Block Veneer
Brown Smooth Face Block
Aluminum Storefront
Prefinished Black, Typ.
Finished Floor
100' - 0" (5035.2)
Top of Parapet
120' - 0"
Precast Concrete
Light Tan Precast sill
Steel Canopy
Painted Red to match metal roof
Light Fixture
Full cutoff exterior light fixture
Steel Guardrail/Handrail
Steel tube railing painted Black
Metal Door
Hollow metal service door
painted to match adjacent
material
10' - 0" Typ.
Metal Cap Flashing
Utility Easement Prefinished Charcoal Grey
Refer to Civil Electrical Gear
Electrical Service gear & meters
Precast Concrete
Light Tan Precast sill
Material Item Description
Senergy, Sentry Stucco Wall System - 5/8" Design Thickness
Color: Almond White to match neighboring Campus West Retail building.
8x16 Smooth face CMU veneer
Color: Brown to match neighboring Campus West Retail building.
Medium ribbed prefinished metal panel
Color: Charcoal Grey
Standing seam metal roof,
Color: Red to match neighboring Campus West Retail building.
1. The applicable site is partially located within the 100-year
flood fringe and floodway in the Canal Importation
Floodplain and is subject to the requirements set forth in
Chapter 10 of the Fort Collins Municipal Code.
2. All construction activities associated with the proposed
project must be proceded an approved floodplain use
permit.
3. Floodplain, floodway, and cross sections per City of Fort
Collins 100 year floodplain map provided by Anderson
Consulting Engineers, Dated 03-06-2006.
4. Building benchmark is City of Fort Collins BM 1-03
Elevation 5046.12 FT - NGVD 29 (or 5049.12 FT
NAVD88).
5. Building finish floor elevation equals 5035.20 FT - NGVD
29 (or 5038.20 FT - NAVD88).
6. Base Flood Elevation (BFE) for the site is 5032.0 FT -
5033.7 FT NGVD 29 (or 5035.0 FT - 5036.7 FT NAVD88).
117 E. Mountain Ave.
Suite 205
Fort Collins, CO 80524
phone 970/224-0630
fax 970/224-0634
www.r4arch.com
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
TBD General Contractor
Elizabeth and City Park, LLC Owner
2537 Research Blvd, Suite 201
Fort Collins, CO 80526
(970) 488-2070
Contact: John Musa
Email: jamusa@israsolutions.com
Larsen Structural Design Structural Engineer
ARCHITECTS
r4arch.com
Address
(970)-
(970)-
Contact:
Email:
19 Old Town Square, Suite 238
Fort Collins, CO 80524
(970) 568-3355
Contact: Blake Larsen
Email: blake@larsensd.com
The Ballard Group Mechanical Engineer
APS Electrical Engineer
1627 Greengate Drive
Ft. Collins, CO 80526
(970) 980-4359
Contact: Matt Doll
Email: mdoll@theballardgroup.com
6931 Broadway
Denver, CO 80221
(970) 381-7462
Contact: Chuck Polson
Email: chuck@apsinc.biz
Interwest Consulting Group Civil Engineer
1218 Ash Street
Windsor, CO 80550
(970) 674-3300
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
TB Group Intitlement/Landscape
444 Mountain Ave.
Berthoud, CO 80513
(970) 532-5891
Contact: Cathy Mathis
Email: cathy@tbgroup.us
Elizabeth &
City Park Corner
Redevelopment
PDP
Enter address here
SA
MR
A1 of 3
Exterior Elevations
PDP Submittal
2012-04
1/8" = 1'-0"
1
North Building Elevation - Elizabeth Street
1/8" = 1'-0"
4
South Building Elevation - Parking Lot
1/8" = 1'-0"
3
East Building Elevation - City Park
1/8" = 1'-0"
2
West Building Elevation
No. Description Date
1 PDP Submittal 3/14/12
Material Legend
Flood Plain General Notes