HomeMy WebLinkAboutCANYON PLACE (331 S. MELDRUM ST.) - PDP - PDP120023 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONSNATIVE SANDSTONE VENEER IN
COURSED ASHLAR PATTERN
("BUFF")
FF 01
100' � 0"
FF 01
100' � 0"
FF 02
115' � 4"
FF 02
115' � 4"
FF 03
128' � 8"
FF 03
128' � 8"
FF 04
142' � 0"
FF 04
142' � 0"
FF 05
155' � 4"
FF 05
155' � 4"
ROOF
168' � 4 1/4"
ROOF
168' � 4 1/4"
MODULAR BRICK VENEER WITH
CAST BASE AND TRIM
ELEMENTS ("RED")
FABRICATED CHANNEL FASCIA
PANEL AT ROOF CANOPY
("OTTER BROWN")
BUILDING STONE VENEER WITH
CAST BASE AND TRIM
ELEMENTS ("WARM GRAY/BUFF")
FABRICATED STEEL SUNSHADE
WITH HANGER RODS, PAINTED
("OTTER BROWN")
EQUIPMENT SCREEN (FINAL
EXTENT DETERMINED BY
EQUIPMENT SIZE AND
PLACEMENT)
REPRESENTATIVE SIGNAGE
(APPROVED UNDER SEPARATE
SUBMITTAL)
CAST SILL
FABRICATED STEEL AND CABLE
GUARDRAIL, PAINTED
("CHARCOAL")
ANODIZED ALUMINUM
STOREFRONT AND GLAZING
SYSTEM WITH INTEGRATED SUN
CONTROL BLADES ("CLEAR")
GROUND FLOOR RETAIL
WINDOWS
REPRESENTATIVE SIGNAGE
(APPROVED UNDER
SEPARATE SUBMITTAL)
PREFINISHED
SCREEN PANEL AT COVERED
BICYCLE STORAGE
FF 02
115' � 4"
FF 02
115' � 4"
FF 03
128' � 8"
FF 03
128' � 8"
FF 04
142' � 0"
FF 04
142' � 0"
FF 05
155' � 4"
FF 05
155' � 4"
ROOF
168' � 4 1/4"
ROOF
168' � 4 1/4"
FABRICATED CHANNEL
FASCIA PANEL AT ROOF
CANOPY ("OTTER BROWN")
PREFINISHED
ARCHITECTURAL CLADDING
SYSTEM WITH EXPRESED
SEAMS ("CHARCOAL")
ANODIZED ALUMINUM
STOREFRONT AND GLAZING
SYSTEM WITH INTEGRATED
SUN CONTROL BLADES
("CLEAR")
NATIVE SANDSTONE
VENEER IN COURSED
ASHLAR PATTERN ("BUFF")
FABRICATED STEEL AND
CABLE GUARDRAIL,
PAINTED ("CHARCOAL")
PREFINISHED METAL ROOF
COPING AND FASCIA
("OTTER BROWN")
EQUIPMENT SCREEN (FINAL
EXTENT DETERMINED BY
EQUIPMENT SIZE AND
PLACEMENT)
BUILDING ELEMENTS BEYOND
SHOWN HALFTONE FOR CLARITY
FF 02
115' � 4"
FF 02
115' � 4"
FF 03
128' � 8"
FF 03
128' � 8"
FF 04
142' � 0"
FF 04
142' � 0"
FF 05
155' � 4"
FF 05
155' � 4"
ROOF
168' � 4 1/4"
ROOF
168' � 4 1/4"
FABRICATED CHANNEL FASCIA
PANEL AT ROOF CANOPY
("OTTER BROWN")
EQUIPMENT SCREEN (FINAL
EXTENT DETERMINED BY
EQUIPMENT SIZE AND
PLACEMENT)
MODULAR BRICK VENEER WITH
CAST BASE AND TRIM
ELEMENTS ("RED")
FABRICATED CHANNEL
FASCIA PANEL AT ROOF
CANOPY ("OTTER BROWN")
SHEET:
OF:
ISSUE DATE:
PROJECT NO:
REVISIONS:
DRAWING TITLE:
9/18/2012 11:46:19 AM P:\11�356 OtterBox Canyon Place\Drawings\01 Arch Current\2012�07�24_331 Meldrum_Schematic.rvt
A�2
2
19 SEP 2012
11�356
CANYON PLACE
PRELIMINARY DEVELOPMENT PLAN
ARCHITECTURAL BUILDING ELEVATIONS
A�2 1/8" = 1'�0"
1 BUILDING ELEVATION � EAST
A�2 1/8" = 1'�0"
2 BUILDING ELEVATION � WEST
SIGNAGE DEPICTED ON THESE BUILDING ELEVATIONS IS INTENDED
TO REPRESENT INTENT AND GENERAL EXTENTS OF SIGNAGE ONLY.
FINAL SIGNAGE SIZE AND PLACEMENT SHALL BE SUBJECT TO
APPLICABLE ZONING PROVISION AND APPROVED UNDER SEPERATE
PERMIT.
PROPOSED MATERIALS
DESCRIPTION PROPOSED COLOR
GLAZING SYSTEMS
ALUMINUM STOREFRONT AND GLAZING SYSTEM "CLEAR ANODIZED"
ALUMINUM STOREFRONT AND GLAZING SYSTEM "DARK BRONZE ANODIZED"
MASONRY
MODULAR BRICK VENEER "RED"
BUILDING STONE (NATURAL OR CAST) "WARM GRAY/BUFF"
NATIVE SANDSTONE VENEER "BUFF"
CAST STONE TRIM "WARM GRAY/BUFF"
METALS
PREFINISHED ROOF COPING AND FASCIA PANELS "OTTER BROWN"
PREFINISHED ARCHITECTURAL CLADDING SYSTEM "CHARCOAL"
PREFINISHED ARCHITECTURAL CLADDING SYSTEM "DARK BRONZE"
A�2
3 SOUTHWEST VIEW FROM MAGNOLIA STREET
A�2
4 SOUTHEAST VIEW FROM MAGNOLIA STREET
EXISTING BUILDING AT 318 CANYON NOT SHOWN IN THIS VIEW FOR
CLARITY OF PROPOSED NEW BUILDING ELEMENTS
ARCHITECTURAL CLADDING
SYSTEM WITH EXPRESED
SEAMS ("CHARCOAL")
ANODIZED ALUMINUM WINDOWS
("DARK BRONZE")
PREFINISHED ARCHITECTURAL
CLADDING SYSTEM WITH
EXPRESSED SEAMS ("DARK
BRONZE")
PREFINISHED METAL ROOF
COPING AND FASCIA ("OTTER
BROWN")
ANODIZED ALUMINUM
STOREFRONT AND GLAZING
SYSTEM WITH INTEGRATED
SUN CONTROL BLADES
("CLEAR")
LINE OF EXISTING 3 STORY
BUILDING AT 318 CANYON
PLAZA BETWEEN
BUILDINGS
OVERALL HEIGHT
78' � 0" +/�
MODULAR BRICK VENEER
WITH CAST BASE AND TRIM
ELEMENTS ("RED")
FABRICATED CHANNEL
FASCIA PANEL AT ROOF
CANOPY ("OTTER BROWN")
PREFINISHED
ARCHITECTURAL CLADDING
SYSTEM WITH EXPRESED
SEAMS ("CHARCOAL")
PREFINISHED
ARCHITECTURAL CLADDING
SYSTEM WITH EXPRESSED
SEAMS ("DARK BRONZE")
FF 01
100' � 0"
FF 01
100' � 0"
FF 02
115' � 4"
FF 02
115' � 4"
FF 03
128' � 8"
FF 03
128' � 8"
FF 04
142' � 0"
FF 04
142' � 0"
FF 05
155' � 4"
FF 05
155' � 4"
ROOF
168' � 4 1/4"
ROOF
168' � 4 1/4"
ANODIZED ALUMINUM WINDOWS
("DARK BRONZE")
PREFINISHED METAL ROOF
COPING AND FASCIA ("OTTER
BROWN")
OVERHEAD COILING
SERVICE/DELIVERY DOOR
SCREEN PANEL AT COVERED
BICYCLE STORAGE
LINE OF OPTIONAL ENCLOSED
ELEVATED WALKWAY FROM
NEW BUILDING TO 318 CANYON
AT 2ND AND 3RD FLOOR LEVELS
FABRICATED STEEL AND CABLE
GUARDRAIL, PAINTED
("CHARCOAL")
PREFINISHED ARCHITECTURAL
CLADDING SYSTEM WITH
EXPRESED SEAMS
("CHARCOAL")
BUILDING STONE VENEER WITH
CAST BASE AND TRIM
ELEMENTS ("WARM GRAY/BUFF")
FABRICATED CHANNEL FASCIA
PANEL AT ROOF CANOPY
("OTTER BROWN")
SHEET:
OF:
ISSUE DATE:
PROJECT NO:
REVISIONS:
DRAWING TITLE:
9/18/2012 11:45:51 AM P:\11�356 OtterBox Canyon Place\Drawings\01 Arch Current\2012�07�24_331 Meldrum_Schematic.rvt
A�1
2
19 SEP 2012
11�356
CANYON PLACE
PRELIMINARY DEVELOPMENT PLAN
ARCHITECTURAL BUILDING ELEVATIONS
A�1 1/8" = 1'�0"
1 BUILDING ELEVATION � SOUTH
A�1 1/8" = 1'�0"
2 BUILDING ELEVATION � NORTH
SIGNAGE DEPICTED ON THESE BUILDING ELEVATIONS IS INTENDED TO
REPRESENT INTENT AND GENERAL EXTENTS OF SIGNAGE ONLY. FINAL
SIGNAGE SIZE AND PLACEMENT SHALL BE SUBJECT TO APPLICABLE
ZONING PROVISION AND APPROVED UNDER SEPERATE PERMIT.