HomeMy WebLinkAboutREGISTRY RIDGE SIXTH FILING (FIFTH FILING, FIRST REPLAT) - MAJOR AMEND. - MJA120002 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLANLOT 1
LOT 2 LOT 3 LOT 4
LOT 5
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
LOT 11
LOT 12
LOT 14 LOT 13
LOT 15
LOT 16
LOT 17
LOT 18
LOT 19
LOT 20
LOT 21
LOT 22
LOT 23
LOT 24
LOT 25
LOT 26
LOT 27
LOT 28
1 2 3 4
5 6 7 8 9
10 11 12 13 14
ABBR. COMMON NAME BOTANICAL NAME QTY. SIZE RMKS.
TREES GT
Shademaster Honeylocust Gleditsia triacanthos inermis
'Shademaster' 8 2" cal. B & B
TC Greenspire Linden Tilia cordata 'Greenspire' 5 2" cal. B & B
FP Marshall Green Ash Fraxinus pennsylvanica 9 2" cal. B & B
QMA Bur Oak Quercus macrocarpa 12 2" cal. B & B
TA American Linden Tilia americana 5 2" cal. B & B
QMU Chinkapin Oak Quercus muehlenbergii 10 2" cal. B & B
PCM Montmorency Cherry Prunis cerasus 'Montmorency' 4 2" cal. B & B
MSW Sweet Sixteen Apple Malus sylvestris 'Sweet Sixteen' 9 1.5" cal. B & B
TOTAL 62
NORTH
PLANT NOTES
1. ALL PLANT MATERIAL SHALL MEET SPECIFICATIONS OF THE AMERICAN
ASSOCIATION OF NURSERYMEN (AAN) FOR NUMBER ONE GRADE. ALL
TREES SHALL BE BALLED AND BURLAPPED OR EQUIVALENT.
2. TREES SHALL NOT BE PLANTED CLOSER THAN 4 FEET TO ANY GAS OR
ELECTRIC LINE AND NO CLOSER THAN 10 FEET TO ANY WATER OR SEWER
LINE. LOCATIONS OF ALL UTILITIES SHALL BE VERIFIED IN THE FIELD PRIOR
TO PLANTING.
3. ALL TREES SHALL BE BALLED AND BURLAPPED, ROOT CONTROL BAGGED,
OR CONTAINERIZED.
4. NO TREES SHALL EXIST, BE PLANTED, OR BE RELOCATED IN UTILITY
EASEMENTS.
5. TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING
CONSTRUCTION SHALL BE CONSERVED FOR LATER USE IN AREAS
REQUIRING REVEGETATION AND LANDSCAPING.
6. THE SOIL IN ALL LANDSCAPE AREAS SHALL BE THOROUGHLY LOOSENED
TO A DEPTH OF NOT LESS THAN EIGHT (8) INCHES AND SOIL AMENDMENT
SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF LANDSCAPE
AREAS TO A DEPTH OF AT LEAST SIX (6) INCHES BY TILLING, DISCING, OR
OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC
YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF
LANDSCAPE AREA.
7. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY
TREES AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED ON
THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE
SIDEWALK AND CURB. THIS PERMIT SHALL APPROVE THE LOCATION AND
SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT MAY RESULT IN
REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF
OCCUPANCY.
8. A CO/TCO WILL NOT BE ISSUED WITHOUT COMPLETION OF LANDSCAPING
OR FINANCIAL SECURMENT IN THE AMOUNT OF 125% OF
MATERIALS/INSTALLATION.
9. COMMUNITY GARDEN PLOTS WILL BE ENCLOSED BY 8' LONG RAILROAD
TIES.
TREE PROTECTION NOTES
1. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE
NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR
FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE.
2. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT
COLLINS FORESTRY STANDARDS.
3. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED
AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF
ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH
METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR
21(+$/) ò
2)7+('5,3/,1(:+,&+(9(5,6*5($7(57+(5(6+$//%(12
STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN
THE FENCED TREE PROTECTION ZONE.
4. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL
PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND
DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT,
CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A
TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.
5. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO
ANY PROTECTED TREE.
6. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED
FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND
UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING
PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION
(G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES
A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM
STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING
CLEARED.
7. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND
FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE
ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED
EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE
AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER
BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS
DESCRIBED IN THE CHART BELOW.
DEVELOPER / APPLICANT
FRED COOKE
11854 BRADBURN BLVD.
WESTMINSTER, CO 80031
303.404.2468
SITE ENGINEER
BLUE SKY ENGINEERING
SAM ELIASON, PE, LEED AP
529 CRESTMORE PL
FORT COLLINS, CO 80521
970.227.7420
401 West Mountain Avenue Suite 100 Fort Collins, CO 80521
fax 970/224.1662 phone 970/224.5828 www.ripleydesigninc.com
Ŷ land planning Ŷ landscape architecture Ŷ
Ŷ urban design Ŷ entitlement Ŷ
FORT COLLINS, COLORADO
REGISTRY RIDGE
FIFTH FILING, FIRST REPLAT
IN ASSOCIATION WITH:
PROJECT No.: R12-022
DRAWN BY: BC
REVIEWED BY:
SEAL:
PDP
ISSUED
No. DESCRIPTION DATE
1 PDP 05.30.12
2
REVISIONS
No. DESCRIPTION DATE
1
2
DRAWING NUMBER:
L1
LANDSCAPE PLAN
SCALE ACCORDINGLY IF REDUCED
HYDROZONE AREA
WATER NEEDED
(GALLONS/SF)
ANNUAL WATER
USE (GALLONS)
HIGH 11703 18 210654
MODERATE 0 10 0
LOW 27135 3 81405
VERY LOW 0 0 0
TOTAL 38,838 AVG.: 7.5 292,059
PLANT LIST
WATER BUDGET CHART
DRYLAND SEED MIX
LEGEND
G:\2012\R12-0XX Registry Ridge\Land Planning\DWG\PDP\Landscape Plan.dwg, 5/30/2012 10:29:04 AM, 1:1