Loading...
HomeMy WebLinkAboutWILLOW BROOK , 2ND FILING , PDP/ FINAL COMPLIANCE - 8-99E F - CORRESPONDENCE -Project: WILLOW BROOK, 2ND FILING, PDP/FINAL COMPLIANCE #8-99/8-99F PDP - Final Compliance REQUEST FOR A RESIDENTIAL PROJECT CONSISTING OF 87 DWELLING UNITS ON 10.6 ACRES. THE 87 UNITS WILL ALL FEATURE TWO BEDROOMS AND ARE DIVIDED AMONG 27 BUILDINGS. ALL BUILDINGS WILL BE TWO-STORIES IN HEIGHT AND FEATURE UNDER-STRUCTURE PARKING GARAGES IN THE BACK. MOST OF THE BUILDINGS CONTAIN THREE DWELLING UNITS. THE PROJECT IS LOCATED SOUTH OF ROCK CREEK DRIVE AND EAST OF CINQUEFOIL STREET (EXTENDED). Project Type: Project Desc: File ID: 8-99E&F Planner: Ted Shepard DMS Project Num: CP021284 ID Topic Issue Status Round Comment By Initial Date 1 zoning The rear setback of buildings must be at least 15' from rear property line. It appears that not all buildings meet that. The code does allow an 8' rear setback for alley accessed garages. However, the rear private drive is not an alley, therefore the 8' setback does not apply in this case. 3.5.2(D)(3) Resolved 1 Peter Barnes 02/22/2002 2 zoning Sheet 1 of 3 is called "project development site plan". I believe it should be called "project development landscape plan" since it is a landscape cover sheet. REPEAT COMMENT 5-2-02 - THE REVISED PLANS STILL LABEL SHEET 1 OF 3 AS A "PROJECT DEVELOPMENT SITE PLAN" IN THE LOWER RIGHT CORNER. THIS NEEDS TO BE CHANGED TO "LANDSCAPE PLAN". Resolved 1 Peter Barnes 02/22/2002 3 zoning Their statement of planning objectives states that these are 2 bedroom units. Since these are multi-family units, that information should be noted on sheet 1 of 2 as part of the Land Use Data. Resolved 1 Peter Barnes 02/22/2002 4 zoning Utility meters need to be screened per 3.5.1(I). Resolved 1 Peter Barnes 02/22/2002 5 zoning The land use data table on sheet 1 of 2 lists "floor area" for single family homes (maximum and minimum). Since there's no single family for the PDP, that should be deleted or changed to floor area for each multi-family building. Resolved 1 Peter Barnes 02/22/2002 7 General We need to continue to work with the developer on the transformer locations. Above grade transformers need to be within 10' of a paved surface. This site will be very expensive due to a lot of front footage. Resolved 1 Janet McTague 02/22/2002 8 General Need to show streetlights on the landscape plan so that tree installation meets design criteria with regards to lighting. Resolved 1 Janet McTague 02/22/2002 3/7/2011 Page 1 Project: WILLOW BROOK, 2ND FILING, PDP/FINAL COMPLIANCE #8-99/8-99F ID Topic Issue Status Round Comment By Initial Date 9 General Water Supply: Fire hydrants are required with a maximum spacing of 800 ft. along an approved roadway. Each hydrant must be capable of delivring 1000 gallons of water per minute at a residual pressure of 20 psi. In residentual applications no building can be greater then 400 ft. from a fire hydrant. UFC 901.2.2.2 Active 1 Michael Chavez 03/05/2002 10 General . Active 1 Michael Chavez 03/05/2002 11 General Address Numerals: Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6-inch numerals on a contrasting background. 97 UFC 901.4.4 Active 1 Michael Chavez 03/05/2002 12 General Street Names: Street names shall be verified and reviewed by LETA and the City Planning Dept. prior to being put into service. 97 UFC 901.4.4 Active 1 Michael Chavez 03/05/2002 13 General Need lighting plan to evaluate safety/security isses. Active 1 Joseph Gerdom 03/12/2002 14 General An update to the subdrain report originally submitted by Anderson Consulting Engineers for the first filing should be submitted addressing the subdrain issues and design pertaining to this project. Resolved 1 Marc Virata 03/13/2002 15 Utility Plan Provide two benchmarks on the utility plan set. 5/22 Provide missing information for the second benchmark provided. It does not appear to be part of the City's Vertical Control. Resolved 1 Marc Virata 03/13/2002 16 Utility Plan Add an additional general note to the cover sheet that all recommendations of the subdrain report by (the subsurface engineer) shall be complied with. Resolved 1 Marc Virata 03/13/2002 17 Utility Plan Ensure that a copy of the plat is also included in the utility plan set. Resolved 1 Marc Virata 03/13/2002 18 General Replace any and all indications of “alley” or “private alley” with “private drive”. 5/22 This correction still needs to be done on the landscape plan. Resolved 1 Marc Virata 03/13/2002 3/7/2011 Page 2 Project: WILLOW BROOK, 2ND FILING, PDP/FINAL COMPLIANCE #8-99/8-99F ID Topic Issue Status Round Comment By Initial Date 19 Utility Plan On the overall utility plan sheet (Sheet 6) revise Note 8 to also include the City of Fort Collins not having responsibilities or liability for the design, installation, operation or maintenance of the subdrain system. Resolved 1 Marc Virata 03/13/2002 20 Utility Plan Add an additional note on Sheet 6 indicating that the City of Fort Collins is not responsible or liable for the design, installation, operation or maintenance of any grinder pumps in the Development. Resolved 1 Marc Virata 03/13/2002 21 Utility Plan The sanitary sewer plan and profile doesn't show a design of the subdrain system. This design is required and should be in accordance with an approved subdrain report pertaining to the 2nd filing. 5/22 See redlines for additional clarification/changes still required regarding this. (Specify SDR 35) 7/10 Please specify SDR 35 for the subdrain. Active 1 Marc Virata 03/13/2002 22 Street Design Provide directional ramps for new construction instead of access ramps that lead to a corner an intersection. Resolved 1 Marc Virata 03/13/2002 23 Street Design The internal (currently unnamed) public street is required to have flowline elevations on both sides of the street, a centerline profile was only provided for the non-looped portion. Resolved 1 Marc Virata 03/13/2002 24 Street Design Provide spot elevations and show the transition points for where the unnamed public street intersects both Southern Cross Lane and the looped portion of the unnamed public street. 5/22 This was not provided in accordance with LCUASS Details 7-32A & B. The transition point to remove the crown is required for Sky Gazer Lane approaching Southern Cross Lane. It is optional for Sky Gazer Lane approaching the looped street. 7/10 The spot elevations provided at these two points should further specify if they are transition points to remove the crown or are strictly just "spot elevations." Active 1 Marc Virata 03/13/2002 3/7/2011 Page 3 Project: WILLOW BROOK, 2ND FILING, PDP/FINAL COMPLIANCE #8-99/8-99F ID Topic Issue Status Round Comment By Initial Date 25 Street Design The loop street is required to be widened where turns are greater than 60 degrees per LCUASS Detail 7-26. 5/22 This was not provided on one street turn as redlined on the plan set. Resolved 1 Marc Virata 03/13/2002 26 Street Design The loop street is required to be a crowned section and not a sloped to one side street section as shown on Sheet 15. Sheet 5 and other sheets appears to show by grading that this is a crowned section - please clarify this roadway section. Assuming a centered crowned road section for the loop street, cross-sections appear to work, though the additional spot elevations would help in further evaluating this. 5/22 The revised loop street with additional elevations indicates a few sections where cross slopes are not to standard. Please rectify. Resolved 1 Marc Virata 03/13/2002 27 Street Design Please provide spot elevations within the loop street at flowline and centerline locations perpendicular to the direction of travel in order to easier verify cross slopes as redlined on the plan set. Resolved 1 Marc Virata 03/13/2002 28 Street Design Please provide spot elevations where the private drives meet the two public streets (Sheets 9 and/or 14.) 5/22 The spot elevations for the private drive out to Northern Lights Drive exceeds the grade specified in 7-29A. 7/10 This still appears to be the case. Active 1 Marc Virata 03/13/2002 29 Street Design Please use different gridlines on the profile views (.25 instead of .3) in order to allow easier measuring with a 30 scale. Resolved 1 Marc Virata 03/13/2002 30 Street Design The private drive profiles (Sheets 10-13) should not have Notes 1-4 on these sheets. Resolved 1 Marc Virata 03/13/2002 31 Street Design Please use LCUASS Detail 7-29A for the private drive detail on sheet 15. Include the additional detail of 7-31 for the culvert/channel design. Resolved 1 Marc Virata 03/13/2002 3/7/2011 Page 4 Project: WILLOW BROOK, 2ND FILING, PDP/FINAL COMPLIANCE #8-99/8-99F ID Topic Issue Status Round Comment By Initial Date 32 Plat Add the attached private drive note on the plat. Resolved 1 Marc Virata 03/13/2002 33 Plat The plat should show existing easements and a note indicating said easements are to be vacated (if appropriate.) Resolved 1 Marc Virata 03/13/2002 34 Plat The plat indicates a drainage easement along the south boundary. The recorded plat document at the City indicates this as a utility easement. Will this easement need to be vacated on the plat? Resolved 1 Marc Virata 03/13/2002 35 General It was previously discussed by the City's Transportation Services group prior to this formal submittal that there was a viewed benefit in having at least 4 of the private drives connect to the perimeter of the existing public streets surrounding this project from the 1st filing. Only one connection is being shown. It should perhaps be discussed further by the applicant on the merits of only one connection. Resolved 1 Marc Virata 03/13/2002 36 Drainage With current site grading, there is concentrated flows in swales between each building that flow over the sidewalks and into the street curb and gutters around the perimeter of the site. Larimer County Urban Street Standards require that sidewalk chases be provided to contain the 2-year flows from these swales. This will create a multitude of chases, which provide maintenance the City would rather not obtain and aesthetically unappealing sidewalks. Please consider lowering the whole site and directing more of the site area toward the interior storm sewers. The little edge of land around the site that can not drain toward the center can sheet flow over the sidewalks, which does not require sidewalk chases. Resolved 1 Wes Lamarque 03/15/2002 37 Drainage Please provide 10-foot separation between storm sewer and all trees. Resolved 1 Wes Lamarque 03/15/2002 38 Drainage There are a couple areas with slopes greater than 4:1. Please revise to 4:1 or 3:1 with a variance request. Repeat 5/21/02. Some areas have slopes around 2:1. Please revise grading, even on Private Property. Resolved 1 Wes Lamarque 03/15/2002 39 Drainage The sub-basin lines on the drainage plan do not reflect the actual grading of the site. Please revise sub-bain boundaries and all hydrology calculations, and relative hydraulic calculations as well. Resolved 1 Wes Lamarque 03/18/2002 3/7/2011 Page 5 Project: WILLOW BROOK, 2ND FILING, PDP/FINAL COMPLIANCE #8-99/8-99F ID Topic Issue Status Round Comment By Initial Date 40 Drainage Please provide a sub-basin summary table with areas, c-factors, and flows on the drainage plan. Resolved 1 Wes Lamarque 03/18/2002 41 Erosion/Sediment Control Please submit an erosion control plan and report per City of Fort Collins specifications. If you have any questions, Please call Bob Zakely at (970) 221-6700. Resolved 1 Wes Lamarque 03/18/2002 42 Drainage Comment #36 from Stormwater no longer applies as Engineering will not be requiring the use of sidewalk chases for the drainage between the buildings that are within landscaped swales. Resolved 1 Marc Virata 03/20/2002 43 Drainage There appear to be multiple instances where drainage swales between buildings are in the same area as pedestrian connections. Resolved 1 Marc Virata 03/20/2002 44 Plat It was discussed that Note #4 may result in the interpretation that the entire development is a blanket easement and that this would result in not being able to build anything within this easement. Perhaps it would be beneficial if this note were removed from the plat. Resolved 1 Marc Virata 03/20/2002 45 General Provide the correct approval blocks on the documents. Approval blocks for Type II projects were used on the planning documents and the plat, it is my understanding and assumption that this is a Type I project. 5/22 This was not provided on the site plan. Resolved 1 Marc Virata 03/20/2002 46 General NO COMMENTS. (7/9/02)This project is in the Fort Colllins Loveland water district. Active 2 Jeff Hill 05/13/2002 47 Drainage Due to a larger amount of flows being directed to the perimeter of the site than what was originally designed for in Willowbrook Filing 1, street capacities will need to be checked with the new flows from filing 2 to make sure street capacities are not being exceeded. Resolved 2 Wes Lamarque 05/21/2002 48 Drainage Street trees along Galileo Drive are about 5 feet from the existing storm sewer built in phase 1. Please field verify the exact location of storm sewer and try to maximize the distance from the street trees. Resolved 2 Wes Lamarque 05/21/2002 3/7/2011 Page 6 Project: WILLOW BROOK, 2ND FILING, PDP/FINAL COMPLIANCE #8-99/8-99F ID Topic Issue Status Round Comment By Initial Date 49 Erosion/Sediment Control Repeat - 6/10/02. Please contact Bob Zakely at (970) 221-6700 with any questions. 1. Standard City of Fort Collins Erosion Control Notes must be on the erosion control plan. If there is not room on the plan, put a note on the plan indicating on which sheet the notes and BMP details can be found. Make sure that none of the erosion control notes currently on sheet 21 do not contradict any of the City of Fort Collins standard erosion control notes. 2. Indicate clearly in your notes what portions of the project are to be seeded and mulched. Active 2 Wes Lamarque 05/21/2002 50 Street Design The outside flowine of the looped street is of issue with the short reverse curves proposed on the design. Resolved 2 Marc Virata 05/22/2002 51 Street Design The two inlets on the loop street are proposed on a curve. Please provide a detail to show this can be built and function. These inlets may have to be relocated outside of a curve. Resolved 2 Marc Virata 05/22/2002 52 Street Design The widened street turns (on the two that were provided, though three are needed) are not symmetrical and it would appear to be beneficial if the turning movements were the same between these two curves. Resolved 2 Marc Virata 05/22/2002 53 Street Design For the vertical design, the flowline of the inner loop is substandard with the lengths of vertical curves provided. Please revise. Resolved 2 Marc Virata 05/22/2002 54 Utility Plan Revisions were received from the design engineer for Willow Brook in order to have underground services pertinent with this project installed with the 1st filing. Please see redlines for comments. Note that these revision need to clearly distinguish between existing, proposed with the revisions, and proposed with the 2nd filing. The utility plans for this project will now need to distinguish portions of the project having already been approved with the pertinent revision(s) to the 1st filing. Resolved 2 Marc Virata 05/28/2002 55 Plat Please see the redlined sheets of the plat for changes to the Notice of Other Documents as well as further clarification on the plat notes. 7/10 Please correct the revisions as redlined. Active 2 Marc Virata 05/28/2002 3/7/2011 Page 7 Project: WILLOW BROOK, 2ND FILING, PDP/FINAL COMPLIANCE #8-99/8-99F ID Topic Issue Status Round Comment By Initial Date 56 Plat After reviewing PFA has no new comments. Please see comments dated 3-5-2002 Active 2 Michael Chavez 06/03/2002 57 Drainage Please show and label new sidewalk chases and concrete channels that were the result of the grading change. Active 3 Wes Lamarque 07/09/2002 58 Drainage Will there be any irrigation taps needed for this site? Active 3 Roger Buffington 07/09/2002 59 General no comments Resolved 3 Kathleen Reavis 07/10/2002 60 Drainage Please add infall/outfall vertical curb detail to the plans. Active 3 Wes Lamarque 07/10/2002 61 Street Design Specify whether driveover curb and gutter is used throughout, including the Tract A median. Active 3 Marc Virata 07/16/2002 62 General Remove all the listed revisions in the revision block on all documents with mylar submittals. Active 3 Marc Virata 07/16/2002 3/7/2011 Page 8