HomeMy WebLinkAboutCOLLINDALE BP, LOT 1, 6TH FILING, GK GYMNASTICS - FINAL COMP - 7-82P - CORRESPONDENCE -Project: COLLINDALE BP, LOT 1, 6TH FILING, GK GYMNASTICS - FINAL COMP., #7-82P
Final Compliance Review
REQUEST FOR FINAL APPROVAL OF A 3-BUILDING COMPLEX FOR A TOTAL OF 49,110 SQ. FT. ON 3.6 ACRES. LOCATED ON THE
NORTHWEST CORNER OF TIMBERLINE ROAD AND LOWE STREET, NORTH OF HARMONY ROAD, SOUTH OF HORSETOOTH ROAD,
AND DIRECTLY WEST OF TIMBERLINE ROAD. ZONING IS E - EMPLOYMENT.
Project Type:
Project Desc:
File ID: 7-82P Planner: Bob Barkeen DMS Project Num: CP011255
ID Topic Issue Status Round Comment By Initial Date
1 Developer needs to coordinate a location for a transformer(s) with Light and
Power Engineering (221-6700).
Active 1 Doug Martine 10/08/2001
2 REPEAT REPEAT COMMENT - Still no street trees being shown along
Timberline. If there is a reason, please address it so I don't keep making the
same comment.
Active 1 Jenny Nuckols 10/08/2001
3 On your legend, R is denoted for Ramps - yet it is not being used on the
actual site plan. Please revise and note R at ALL HC ramps inc those at
entrance/ exits
Active 1 Jenny Nuckols 10/08/2001
4 Remove topo lines from final site plan Active 1 Jenny Nuckols 10/08/2001
5 Active 1 Michael Chavez 10/10/2001
6 Lighting: Lighting plan needed. Several lighting issues from site plan:
1. Location of parking lot lights and deciduous trees will conflict.
Intermediate and mature heights
will result in large, underlit areas of the parking lot.
2. Parking area adjacent to Timberline has no dedicated light source.
3. East property entrance needs pole light. (West entrance will be
shielded by Norway Maples.)
4. All building entrance/exits should provide 0.7fc of verticle illumination
at an arc of 50' from
opening to provide safe and secure access for evening users.
Active 1 Joseph Gerdom 10/10/2001
7 Utility plan cover sheet: Please correct notes as redlined and add the PE
statement (item I.J from checklist).
Resolved 1 Katie Moore 10/16/2001
8 Plat: See redlines. Resolved 1 Katie Moore 10/16/2001
3/7/2011 Page 1
Project: COLLINDALE BP, LOT 1, 6TH FILING, GK GYMNASTICS - FINAL COMP., #7-82P
ID Topic Issue Status Round Comment By Initial Date
9 Overall utility plan: Please label driveways as concrete to the ROW. Resolved 1 Katie Moore 10/16/2001
10 Please call out abutment locations. Resolved 1 Katie Moore 10/16/2001
11 Please label retaining wall. Resolved 1 Katie Moore 10/16/2001
12 Please darken striping/light lines. They aren't reproducible. Resolved 1 Katie Moore 10/16/2001
13 Grading plan: Where are the abutments (repeat)? Resolved 1 Katie Moore 10/16/2001
14 Grading plan: See redlines. Resolved 1 Katie Moore 10/16/2001
15 Please provide smooth connection to sidewalk to the west (still offset by
about 2 feet).
Resolved 1 Katie Moore 10/16/2001
16 Detail sheet 7: Where will the drive-over curb be used? Please remove
detail if not used.
Resolved 1 Katie Moore 10/16/2001
17 Detail sheet 8: If the off-site vertical curb and gutter is for use on Lowe or
Timberline, it should be labeled as 7-20A. See sheet for additional redlines.
Resolved 1 Katie Moore 10/16/2001
18 Landscape plan: Where are the street trees along Timberline? Resolved 1 Katie Moore 10/16/2001
19 Landscape plan: Please see redlines for additional comments. Resolved 1 Katie Moore 10/16/2001
20 Site plan: Please label ROW, all retaining walls, sidewalk widths where
missing, and see redlines for additional comments.
Resolved 1 Katie Moore 10/16/2001
21 Please submit a soils report. Resolved 1 Katie Moore 10/16/2001
22 A minimum 6" fire line is required. Active 1 Michael Chavez 10/17/2001
23 No further comments Active 1 Mark Jackson 10/17/2001
3/7/2011 Page 2
Project: COLLINDALE BP, LOT 1, 6TH FILING, GK GYMNASTICS - FINAL COMP., #7-82P
ID Topic Issue Status Round Comment By Initial Date
24 Please show the location of the abutments for the pedestrian bridge on the
grading plan with a detail showing elevations and exact location. Abutments
should not reduce the cross-sectional area of the channel. Also, please
provide some erosion protection around the abutments, posibly erosion
control fabric until grasses mature.
Active 1 Wes Lamarque 10/17/2001
25 Erosion/Sediment Control Comments:
There are no PS and EFF calculations.
There are no standard erosion control notes on the plan.
If all three pads are not to be built on (and/or the entire parking lot to be
paved in the initial site construction), any areas disturbed will have to be
seeded and mulched. If partial site development is to occur and it is the
intent to leave the remainder of the site undisturbed, it needs to be so stated
in a note on the plan.
Surety calculations contain unit costs that are in some cases too high. This
costs your client unnecessarily.
You show straw bales in the existing swale with a concrete pan. Straw bales
dont work on concrete, please change this BMP to something that will work.
Active 1 Wes Lamarque 10/17/2001
26 No Issues- Active 1 Doug Moore 10/19/2001
27 No comment Active 1 Jeff Hill 10/19/2001
28 Street trees will need to shown on the site/landscape plan pursuent to the
condition of approval.
Active 1 Bob Barkeen 10/24/2001