HomeMy WebLinkAboutTIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT - 01-97B - CORRESPONDENCE -Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT Major Amendment Request for the Phase 3 addition - 86,400 sq ft addition to northside of building for auditorium to seat approximately 3500 people. There will be additional parking lot modifications. The project is located at 2908 S. Timberline Rd., on the east side of S. Timberline Road, south of East Drake Road and north of the Fort Collins High School and Pinecone Apartments. The zoning is LMN - Low Density Mixed Use Neighborhood. Project Type: Project Desc: File ID: 01-97B Planner: Ted Shepard DMS Project Num: CP071965 ID Topic Issue Status Round Comment By Initial Date 1 Zoning [2/26/07] Need to clarify if this major amendment supercedes the current minor amendment that is in for review. The minor amendment includes phase 2 and some parking changes on the south, including trash dumpster locations. However, the major amendment also shows parking and trash changes on the south, but they are different from those shown on the minor amendment. Which plan is correct? If it's the major amendment, then should the minor amendment be withdrawn? Resolved 1 Peter Barnes 02/26/2007 2 Zoning [2/26/07] Per Section 3.2.2(K)(5)(d) of the Land Use Code, 28 handicap parking spaces are required. However, the land use data indicates only 26 spaces provided. Resolved 1 Peter Barnes 02/26/2007 3 Zoning [2/26/07] In order to determine if enough parking is being provided per Section 3.2.2(K)(1)(h) of the Land Use Code, the plan needs to indicate the seating capacity of the room or rooms that will be used during worship services. Resolved 1 Peter Barnes 02/26/2007 4 Zoning [2/26/07] Show distance from Phase 3 addition to north property line. Resolved 1 Peter Barnes 02/26/2007 5 Zoning [2/26/07] This is in the residential neighborhood sign district. Need to show possible wall sign location of any wall signs. Resolved 1 Peter Barnes 02/26/2007 6 General [2/28/07] No comments. Active 1 Doug Martine 02/28/2007 3/7/2011 Page 1 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 7 Fire [5/23/07] The fire lane needs to be recorded by separate document, if the property is not going to be replatted. (I worked on the fire lane location and specifications with folks from Northern Engineering.) [3/6/07] REQUIRED ACCESS: A fire lane is required. The fire lane shall be located so that it provides unobstructed access to the Fire Department (automatic sprinkler) Connection. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval PRIOR to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements:  Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites.  Have appropriate maintenance agreements that are legally binding and enforceable.  Be designated on the plat as an Emergency Access Easement.  Maintain the required minimum width of 20 feet throughout the length of the fire lane. 97UFC 901.2.2.1; 901.3; 901.4.2; 902.2.1 Resolved 1 Carie Dann 03/06/2007 8 Fire [3/6/07] WATER SUPPLY: Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter. If possible, a fire hydrant shall be located within 75 feet of the Fire Department Connection. 97UFC 901.2.2.2 Active 1 Carie Dann 03/06/2007 9 General [5/25/07] Adding a note to the plan is not enough. Add to schedule so that all lights adjacent to the natural feature can be identified separately from other fixtures. [4/23/07] Photometric Plan provided. Use house-side shields on fixtures adjacent to Foothills Channel. [3/6/07] Photometric Plan is required. Resolved 1 Dana Leavitt 03/06/2007 10 Landscape Plan [3/6/07] Native plant species are to be used in the buffer zone for the Foothills Channel. Additional plant material is needed in the buffer zone to mitigate the view and use of the parking lot adjacent to the channel and meet Sections 3.4.1(E)(1), 3.4.1, 3.4.1(L). Resolved 1 Dana Leavitt 03/06/2007 3/7/2011 Page 2 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 11 General [3/6/07] Locate the top of bank and edge of channel for the Foothills Channel on the Site Plans and the Landscape Plans. Contact Dana Leavittat 224-6143 to set up a site visit to preliminarily identify top of bank and existence, or lack of ecological characterisitcs of the channel. Resolved 1 Dana Leavitt 03/06/2007 12 General [3/6/07] Limits of Development (LOD) shall be established and shown on the Site Plan and the landscape PLan. Contact Dana Leavitt to set up a meeting to establish. Resolved 1 Dana Leavitt 03/06/2007 15 Landscape Plan [3/6/07] Additional screening and buffering per Section 3.2.1(E)(4)(b) along the east property line to address parking lots adjacent to residential uses. Resolved 1 Dana Leavitt 03/06/2007 16 Landscape Plan [3/6/07] Screening is needed behind the trash enclosure next to the adjoining property. Resolved 1 Dana Leavitt 03/06/2007 17 Site Plan [3/6/07] Provide parking lot analysis to demonstrate that 10% of the proposed parking lot area square footage is interior landscape islands, per 3.2.2(M)(1). Resolved 1 Dana Leavitt 03/06/2007 18 Fire [3/6/07] AUTOMATIC FIRE SPRINKLERS: The proposed additions (Phases 2 and 3) shall be equipped with automatic fire sprinklers; this sprinkler system shall form a single system with the existing sprinkler system. Please note on the site plan, the location of the FDC. 97UBC Table9-B (City of Fort Collins Amendment). Active 1 Carie Dann 03/06/2007 19 Fire [3/6/07] KNOX BOX REQUIRED: Poudre Fire Authority requires a “Knox Box” to be mounted on the front of every new building equipped with a required fire sprinkler system or fire alarm system. 97UFC 902.4; PFA BUREAU POLICY 88-20 Active 1 Carie Dann 03/06/2007 20 Fire [3/6/07] FIRE WATER LINE: Where is the existing fire line that supplies the automatic fire sprinklers? Construction of any portion of a building over the existing fire line is prohibited. Active 1 Carie Dann 03/06/2007 21 Fire [3/6/07] CONSTRUCTION/DEMOLITION: The project must conform to applicable standards for construction/demolition as specified in the Uniform Fire Code. Active 1 Carie Dann 03/06/2007 3/7/2011 Page 3 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 22 Fire [3/6/07] OCCUPANT LOAD SIGNS: Any room having an occupant load of 50 or more where fixed seats are not installed, and which is used for assembly purposes, shall have the capacity of the room posted in a conspicuous place on an approved sign near the main exit from the room. Such sign shall be maintained legible by the owner or the owner’s authorized agent and shall indicate the number of occupants permitted for each room use. 97UFC 2601.16.1 Active 1 Carie Dann 03/06/2007 23 Fire [3/6/07] COMMERCIAL COOKING FIRE EXTINGUISHING SYSTEM: With the production of grease-laden vapors, an approved, automatic fire-extinguishing system shall be provided for the protection of commercial-type cooking equipment. 97UFC 1006.1; 1006.2.1 Active 1 Carie Dann 03/06/2007 24 Fire [3/6/07] TRAFFIC FLOW: How is the church proposing to deal with a possible increase of traffic entering and leaving the parking lots? Will large numbers of private passenger vehicles be able to yield to emergency vehicles, if the private vehicles do not enter or exit (particularly exit) the parking lot other than at the traffic signals? Active 1 Carie Dann 03/06/2007 25 General [3/7/07] In the Project Description several statements were made in regards to natural areas, wetlands and buffers. First, a site visit is neccesary to determine if an Ecological Characterization Study will be needed per Section 3.4.1(D) of the LUC. Second, until the feature (the Foothills Channel) hs been physically defined, the location of the buffer cannot be established. After the location of the buffer has been established per Section 3.4.1(E)(1) and the Buffer Zone Table of 3.4.1(E), a determination will be made on the size of the buffer. Third, the landscape material within the buffer as shown on the landscape plan does not meet the standards as articulated in Section 3.4.1(E)(1)(e) and (g). Resolved 1 Dana Leavitt 03/07/2007 26 Utility Plans [5/25/07] If light types are hard to read, provide another type where overlap occurs. [4/24/07] Show top of embanment of existing conditions also, otherwise ok. Show LOD on all plan sets with in the Utility Plans. [3/7/07] The edge of the Foothills Channel and the top of embankment needs to be located on the Existing Conditions Plan, the Demolition Plan sheets, the Horizontal Control Plan sheets, the Grading Plan sheets and the Overlot Grading Plan sheets. The Limits of Development (LOD), once established, shall be show on all of the plans referenced above. Resolved 1 Dana Leavitt 03/07/2007 3/7/2011 Page 4 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 27 Utility Plans [3/7/07] The Demolition Plan sheets show many exisitng trees to be removed. There is no mention whether or not any of the removed trees will be saved and eventually replanted as part of the Landscape Plan. The potential removal of this many trees will impact the amount of solar radiation coming off of the paved surfaces and the visual quality of the site. At a minimum, contact Tim Buchanan, the City Forester to address this issue. Tree protection standards need to be added to the Demolition plans for the trees shown to be protected, per Section 3.2.1(F), of the LUC. Resolved 1 Dana Leavitt 03/07/2007 29 Landscape Plan [3/7/07] Add Tree Protection stadards to the landscape Plan, per Section 3.2.1(F), of the LUC. Resolved 1 Dana Leavitt 03/07/2007 30 Traffic Engineering [3/13/07] The Traffic Study is acceptable. Active 1 Eric Bracke 03/13/2007 31 Water/Wastewater [3/13/07] Show the water/sewer services and fire line which were stubbed out in the original construction for the Phase III building addition. Will these be used for the building addition? Or should the stubs be abandoned now? Resolved 1 Roger Buffington 03/13/2007 32 Water/Wastewater [3/13/07] PVC vs DIP pipe? Resolved 1 Roger Buffington 03/13/2007 33 Water/Wastewater [3/13/07] See redlined utility plans for other comments. Resolved 1 Roger Buffington 03/13/2007 34 Landscape Plan [4/24/07] Adjust tree locations to provide 10 foot minimum separation from all water mains. [3/13/07] Show water/sewer mains and service lines. Adjust plantings to meet separation requirements in Note 11 on Sht 9 of Landscape Plan. Resolved 1 Roger Buffington 03/13/2007 3/7/2011 Page 5 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 35 General [5/22/07] Given that the minor amendment is being shown on the plans, please amend the note on the cover sheet regarding the minor amendment to read as follows: "Minor Amendment design for Timberline Church was approved on May 16, 2007 via revisions to the Timberline Church construction plan set. Information shown regarding the minor amendment within this plan set is for informational purposes only. In the event of a discrepancy between the information shown in this plan set and the revisions to the Timberline Church plan set, the revisions to the Timberline Church plan set shall govern. As-built/record drawing information pertaining to the minor amendment shall be shown on the revision drawings." If there are questions or concerns regarding this proposed note, please let me know. [4/24/07] The response from Northern indicated that the minor amendment information on the construction plan set is to remain as the site contractor will be building off the plans. If this is the case, why is there a minor amendment being approved prior to this major amendment showing the exact information? It seems that the minor amendment should just then be withdrawn if the contractor isn't intending to build off the revised sheets of the minor amendment that shows this same information. I'd like to suggest a meeting with Northern, myself, and Sheri Langenberger who is reviewing the minor amendment. [3/14/07] I'd like to see the minor amendment indications on the drawings to be "faded back" so that it is evident that the information shown in not being approved. With the assumption that the minor amendment will be approved prior to the major amendment, please add a note at the time of mylars for the major amendment indicating the approval date of the minor amendment. Resolved 1 Marc Virata 03/14/2007 36 General [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. [3/14/07] The right turn lane off of Timberline Road appears to fall short of turn lane length requirements. A variance request should be submitted addressing this. I don't forsee a concern with its approval, but it should at least be submitted for evaluation. (Note: This observation is based upon the present design submitted with a right turn lane that extends along the CSU property.) Resolved 1 Marc Virata 03/14/2007 3/7/2011 Page 6 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 37 General [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. [3/14/07] The construction of the right turn lane appears to have a substanative impact on the CSU property. Sheet 13 of the construction plan set even shows a proposed contour line cutting through one of the buildings and a 25% grade from the sidewalk to that building. What is the plan for mitigating the impact to CSU? Will a building be removed? A letter of intent is required from CSU prior to a hearing. Resolved 1 Marc Virata 03/14/2007 38 Construction Plan [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. [3/14/07] Please show additional existing countours on the CSU property in order to ascertain how the right turn lane construction ties into the existing property. Resolved 1 Marc Virata 03/14/2007 39 Construction Plan [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. [3/14/07] The sidewalk crossing the driveway along Timberline appears awkward. I'd like to suggest keeping the sidewalk closer to Timberline to head straight across the driveway rather than bring it closer to the site. Resolved 1 Marc Virata 03/14/2007 40 Construction Plan [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. [3/14/07] Additional design information is needed for the right turn lane prior to a hearing. What are existing flowline grades and spot elevations of the surrounding area? At the time of final a flowline profile and cross sections will be needed. Resolved 1 Marc Virata 03/14/2007 41 Construction Plan [5/22/07] On Sheet 6 the demo plan indicates removal of work along Timberline, I'm assuming that this needs to be rectified with the right turn lane no longer being constructed. [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. (Note that if the City's Traffic Engineer is okay with not constructing the right turn lane, the plan set still reflects demo work occuring in this area.) [3/14/07] What is the hatched out area along Timberline on the plan set, and is the median being proposed for modification? Resolved 1 Marc Virata 03/14/2007 42 Site Plan [3/14/07] The vicinity map is not scannable. Resolved 1 Marc Virata 03/14/2007 3/7/2011 Page 7 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 43 Construction Plan [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. [3/14/07] Please show existing striping along Timberline in conjunction with the demo plan to verify if patching limits are appropriate. Resolved 1 Marc Virata 03/14/2007 44 General [5/22/07] The response indicated that the emergency access easement has been processed with the minor amendment, in reality it will br processed with this major amendment and the minor amendment was approved without it. [4/24/07] Deeds of dedication were provided, which require a $250 Transportation Development Review Fee for each deed. Note that Sheri Langenberger had requested the emergency access easement as part of the minor amendment, which will likely be process through the minor amendment instead of the major amendment. [3/14/07] Will the various easement and right-of-way dedications be done via plat or deed? Resolved 1 Marc Virata 03/14/2007 45 General [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. [3/14/07] A 15' utility easement is typically required behind the right-of-way. With the right turn lane being done, a 15' easement can't be done behind the right-of-way. The utility providers will need to okay this. Resolved 1 Marc Virata 03/14/2007 46 Construction Plan [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. [3/14/07] Please provide a striping plan sheet that shows the right turn lane in conjunction with the existing lanes along Timberline. Resolved 1 Marc Virata 03/14/2007 47 Traffic Engineering [3/14/07] I recently discovered that the Church does not intend to use Police traffic control at the key intersections as was stated in the TIS. If this is so, then the traffic study needs to be revised to analyze the queues for the SB left turns into the site to determine if there will be an impact to the SB through lanes. Active 1 Eric Bracke 03/14/2007 48 General [3/15/07] On all plans - Site to Utility plans, extend rxisitng conditions of Foothills Channel as it turns east so that the extent of the buffer can be shown on the property. Resolved 1 Dana Leavitt 03/15/2007 3/7/2011 Page 8 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 49 General [3/15/07] Please ensure all documents have the same title, the title of the construction plans "Timberline Church Expansion" is fine. The site plan title of "Timberline Church" is problematic if used on all the documents as it would share the title of the original project. Resolved 1 Marc Virata 03/15/2007 50 Construction Plan [4/24/07] Carried over pending the City Traffic Engineer's okay in not constructing the right turn lane. [3/15/07] Please show existing Timberline Road (flowline curb and gutter, median, striping (on the striping and demo plan) up to the northern boundary of the overall site. Resolved 1 Marc Virata 03/15/2007 51 Release rate from detention pond [3/22/07] The modeling shows an increase in flows downstream at one node. Please revise detention release rate in order to ensure that no adverse conditions occur downstream due to release from this site. Active 1 Basil Hamdan 03/22/2007 52 Utility Plans [3/22/07] Please indicate where ponding in the parking lot would occur, make sure it is no more than 6 inches in the 100 year storm scenario. Call out existing drainage structures such as pans, inlets and pipes. Provide a spillway location and design for the detention pond. Provide one foot of cover on pipe is possible. Storm Line A-1 seems to have quite a bit of exposed pipe in the detention pond, please address by shortening pipe or altering grading. Shallow cover is also a problem at inlet A-3 and C-3, accounting for pipe thickness some of these pipes would be extruding into the parking lot. Please see redlines for additional comments. Active 1 Basil Hamdan 03/22/2007 3/7/2011 Page 9 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 53 Landscape Plans [3/22/07] Please indicate what the detention pond mix is on the landscape plan. A dry seed mix was found but it was not clear whether that was the same as the detention pond mix. Detention pond landscaping should be altered to use water tolerating grasses in shallow swales or pans should be added. It is recommended that the water quality portions of the pond be vegetated with wetland grasses. Please specify how the disturbed area on the City of Fort Collins property will be revegetated. Specify a seed mix for that area. Active 1 Basil Hamdan 03/22/2007 54 Demolition Plans [3/22/07] Please indicate what will be done to the existing tiles/pipes that are located within the future construction area. These should be called out to be abandoned and removed if no longer in use, otherwise, they should be tied back into any subdrain system they may be serving. Indicate which existing storm sewers are to be protected in place. Indicate any existing trees that will be protected, specifically in the channel area. Active 1 Basil Hamdan 03/22/2007 55 Details [3/23/07] Please use the updated water quality outlet detail, there is one new revision to the detail used. I can email you a copy of the latest detail, if you send me a request at bhamdan@fcgov.com Please turn on the layer for the inlet detail. Clarify whether the concrete pan detail will be used throughout the project. Specify what riprap details will be used at what location. Provide a detail for the one foot chase called out in the parking lot. Active 1 Basil Hamdan 03/23/2007 3/7/2011 Page 10 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 56 Grading Plans [3/23/07] Clean up text make it scannable. Add concrete pans to swale at less than 2 % at eastern edge of parking lot, as well as to the bottom of the detention pond. Add notes that require that the channel disturbance will be limited to the delineated construction area. Grading on USDA property will require an easement from that property owner. Active 1 Basil Hamdan 03/23/2007 57 Erosion Control Plans [3/23/07] Specify what sheets are being used as erosion control plans, label appropriately, provide erosion control standard notes, schedule and details. Provide erosion control efficiency calcs, and escrow. Use tru dams in parking lot inlet. Provide silt fence along disturbance in the channel. Active 1 Basil Hamdan 03/23/2007 58 General [4/23/07] The response letter indicated that the right turn lane into the site was removed after discussion with the church and traffic engineer consultant. In talking with the Traffic Engineer, he'd like a letter or information from the traffic engineer consultant as to why this is no longer being provided. Resolved 2 Marc Virata 04/23/2007 59 Easements [4/24/07] Will the existing and proposed drainage easements be vacated and dedicated by separate document ? If so please provide deeds of dedication. Active 2 Basil Hamdan 04/24/2007 60 Demolition Plans [4/24/07] Please indicate that the exiting outlet box and pipe in the existing pond is to be protected in place. Active 2 Basil Hamdan 04/24/2007 61 Phasing Plans [4/24/07] Please label the current major amendment as Phase 1. Phase numbering should be clarified so that it includes only those phases that are being approved by these plans. Active 2 Basil Hamdan 04/24/2007 3/7/2011 Page 11 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 62 Utility Plans [4/24/07] Please move storm manhole A2 for storm Line A north away from the Foothills Channel, in order to minimize potential grading impacts on channel. As currently designed the manhole is right at the edge of City property. Please realign new proposed outlet pipe so that it is more in line with the channel, it now comes out at a 90 degree angle, and could cause serious erosion along the channel bank. Active 2 Basil Hamdan 04/24/2007 63 Erosion Control Plans [4/24/07] Please ad an erosion control schedule to the plan as well as the a schedule. Please provide some silt fence protection around the outlet pipe that will be bult out into the Foothills Channel. Active 2 Basil Hamdan 04/24/2007 64 Water/Wastewater [4/24/07] Revise the various notes on abandonment of water services to include the removal of the curb stops. Resolved 2 Roger Buffington 04/24/2007 65 Landscape Plans [4/24/07] Please specify how the disturbed area within the Foothills Channel where the pipe outlet from the detention pond is being installed will be re-vegetated. Re-vegetation should match existing seed mix for the channel. Active 2 Basil Hamdan 04/24/2007 66 Grading Plans [4/24/07] Please call out pond spillway location and elevation on the grading plans. Please provide erosion protection for the proposed spillway overflow structure downstream of the spillway. Is the existing pedestrian path the top of the spillway ? Did you check path elevation ? Active 2 Basil Hamdan 04/24/2007 67 Storm Sewer Profiles [4/24/07] Please call out the ponding elevations in the parking lot on the storm line profiles. Active 2 Basil Hamdan 04/24/2007 68 Water quality pond outlet details [4/24/07] Please provide an actual water quality outlet box detail with the proposed outlet plates. The detail provided is an outdated one with the generic water quality plate detail, rather than the actual ones. Active 2 Basil Hamdan 04/24/2007 3/7/2011 Page 12 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 69 Phasing Plans [4/24/07] Echoing Stormwater comments, please relabel the phasing plan as follows: "Major Amendment Phase" is "Phase 1" "Major Amendment Future Phase" is "Phase 2" "Major amendment" should just be removed from any indication on the plan set. It is my understanding that the existing building is intended to be Phase 1, this is problematic for the City, as we'd be issuing Phase 2 and Phase 3 DCP's for "Timberline Church Expansion" without a Phase 1. Resolved 2 Marc Virata 04/24/2007 70 Phasing Plans [5/22/07] Please show work that is being done within the channel area as being part of Phase I. The storm sewersystem that goes through Phase II bringing flows from the existing parking lot should be designated to be built with Phase I. Provide an interim grading plan for swale along east property line for Phase I plans. Please call for revegetation of areas within Phase II that will be disturbed during Phase I grading operations. Active 3 Basil Hamdan 05/22/2007 71 Easements [5/22/07] Please provide separate easements for areas within future pond that are being dedicated as drainage easements. Active 3 Basil Hamdan 05/22/2007 72 Details [5/22/07] Please provide an actual detail for Line E riprap with dimensions. Active 3 Basil Hamdan 05/22/2007 73 Landscape Plan [5/22/07] There is a conflict between the proposed storm line and the tree in one of the islands in Phase II construction, please adjust tree location to provide a minimum of 5 feet of clearance. Active 3 Basil Hamdan 05/22/2007 74 Utility Plans [5/22/07] Please provide riprap on downstream end of spillway. Resolved 3 Basil Hamdan 05/22/2007 75 General [6/21/07] Carried over for reference. [5/24/07] At the time of final submittal after public hearing, a Transportation Development Revew Fee of $1,000 is required. A Development Construction Permit (DCP) will be required prior to any work pertaining to this major amendment. Active 3 Marc Virata 05/24/2007 3/7/2011 Page 13 Project: TIMBERLINE CHURCH EXPANSION MAJOR AMENDMENT ID Topic Issue Status Round Comment By Initial Date 76 Site Plan [6/21/07] Technical Services has indicated that there are still areas of concern. See attached redlines. [5/24/07] Technical Services has redlined areas on the site plan that may be of concern for scannability purposes. Please see the attached redlines. Active 3 Marc Virata 05/24/2007 77 Fire [6/19/07] PFA has no additional comments or concerns at this time. Active 4 Carie Dann 06/19/2007 78 Utility Plans [6/20/07] Please add a boulder to the riprap detail for the outfall into the Foothills Channel to hide the pipe outfall. Plans look OK for mylars submittal at final. Active 4 Basil Hamdan 06/20/2007 79 Erosion Control Plans [6/20/07] The erosion control security estimate is calculated for Phase I. Please clarify in the estimate calculations sheet that the figure calculated is for Phase I improvements only. A separate Phase II security escrow calculation should also be provided. Active 4 Basil Hamdan 06/20/2007 80 Stormwater Fees [6/20/07] Since no building permit is associated with Phase I improvements please add a note to the phasing plans stating that fees for Phase I improvements will need to be paid prior to issuance of a DCP for Phase I. Fees for the future Phase II improvements can be associated with a building permit of a DCP for Phase II. Please provide a breakdown for the increase in impervious area associated with Phase I and those associated with Phase II improvements, in order to subdivide the stormwater fees into two separate amounts, one for each phase. Active 4 Basil Hamdan 06/20/2007 81 General [6/21/07] With the final submittal, we'll discuss permitting process via the DCP and whether an amendment to the original development agreement and/or a new development agreement is required. Active 4 Marc Virata 06/21/2007 3/7/2011 Page 14