HomeMy WebLinkAboutHARMONY TECH PARK - 01-08 A - CORRESPONDENCE -Project: HARMONY TECH PARK, 3RD FILING, CUSTOM BLENDING PDP - TYPE I AND FINAL PLANS PDP - Final Compliance Request for a 31,775 sq ft building consisting of an office, light manufacturing and warehouse usages on a 3 acre parcel in Harmony Technology Park. Located at Lady Moon and Precision Dr, directly south of Harmony Technology Park. Zoning is HC - Harmony Corridor. (Office-7,947 sq ft two story office located on the north side of the building, facing Precision Drive. Light manufacturing- 9,249 sq ft Liquid Blending and extraction portion of the building is housed in a precast concrete wall panel constrution directly to the south of the office component. 6,930 sq ft Dry Blending storage and packaging portion is at the southern end of the facility with the same 24' height as the Liquid Blending/Extraction Area. Warehouse-7,649 sq ft finished warehouse located between the liquid and dry production areas being the tallest at 37' feet. (This Project Type: Project Desc: File ID: 01-08/A Planner: Ted Shepard DMS Project Num: CP082079 ID Topic Issue Status Round Comment By Initial Date 1 Plat [2/4/08] The nearest power is at Lady Moon Dr. A developer of the Harmony Technology 3rd filing will need to coordinate with Light &Power Engineering for the installation of electric facilities and the electric development charges for this plat. This will bring high voltage power to the corner of each lot. An ODP would be helpful in planning electric facilities to the general area. The plat needs a north arrow and scale block. Active 1 Doug Martine 02/04/2008 2 Electric Utility [2/4/08] The developer of the Custom Blending lot will need to coordinate power requirements and electric development charges with Light & Power Engineering. (970)221-6700. Active 1 Doug Martine 02/04/2008 3 Electric Utility [2/4/08] The transformer location shown will need to be adjusted to be a minimum of 2 ft. from the back of the sidewalk. Active 1 Doug Martine 02/04/2008 4 Landscape Plan [2/4/08] A streetlight is planned for immediately west of the easterly driveway at the point where the curb becomes straight. The street tree to the west of this point will need to be either relocated to be a minimum of 40 ft. from the streetlight, or changed to an ornamental type which has a minimum clearance of 15 ft. Active 1 Doug Martine 02/04/2008 5 Zoning [4/24/08] [2/7/08] Please show building envelope, footprint and dimensions on site plan. 4-24-08 Building dimensions are still not shown on the site plan Active 1 Jenny Nuckols 02/07/2008 6 Zoning [2/7/08] Please note width of parking stalls on site plan. Resolved 1 Jenny Nuckols 02/07/2008 3/7/2011 Page 1 Project: HARMONY TECH PARK, 3RD FILING, CUSTOM BLENDING PDP - TYPE I AND FINAL PLANS ID Topic Issue Status Round Comment By Initial Date 7 Zoning [4/24/08] [2/8/08] Add note to landscape notes regarding installation of landscaping prior to issuance of CO. 4-24-08 Landscape assurance note needs to include all landscaping, not just that in the drainage tract, but all landscaping on that site. Active 1 Jenny Nuckols 02/08/2008 8 General [2/7/08] The planning documents have the title "Custom Blending" while the engineering/plat documents have the title "Harmony Technology Park 3rd Filing". Please have the document titles match. Harmony Technology Park 3rd Filing, Custom Blending would be fine for the title. Resolved 1 Marc Virata 02/07/2008 9 Construction Drawings [2/7/08] The access ramps at all the public street intersections need to be directional instead of leading to the corners (middle). Please show future access ramps at the corners of the street intersections being built in order to ensure that when these corners are poured the future access ramps can then be provided without having to remove curb. Resolved 1 Marc Virata 02/08/2008 10 General [5/6/08] Carried over for reference. [2/8/08] The offsite pond (Pond B) shown on the northwest corner of Technology Parkway and Rock Creek Drive is considered development and as such the street frontages abutting Pond B needs to be obligated for. Sidewalk along Technology Parkway and Rock Creek Drive abutting Pond B would need to be escrowed for if not being built at this time. If a repay was filed with the City for the construction of Rock Creek Drive, the frontage abutting Pond B would also be required. Active 1 Marc Virata 02/08/2008 11 General [5/6/08] Carried over for reference. [2/8/08] The offsite pond (Pond B) should have a 9 foot utility easement dedicated along Technology Parkway and Rock Creek Drive. Active 1 Marc Virata 02/08/2008 3/7/2011 Page 2 Project: HARMONY TECH PARK, 3RD FILING, CUSTOM BLENDING PDP - TYPE I AND FINAL PLANS ID Topic Issue Status Round Comment By Initial Date 12 General [2/19/08] The enhanced crosswalk shown on the south side of the Precision/Tech Parkway intersection has some concerns. In checking with Traffic Operations, they wouldn't typically install a crosswalk without access ramps and a sidewalk network on both sides to connect to. Given that there's no sidewalk in the general area being proposed at this time, perhaps crosswalk installation should at least be deferred. I've also had some further discussion with Transportation Planning and Traffic and the consensus was that the location of the crosswalk itself seems a bit odd as we're not seeing this area having a higher amount of pedestrian traffic as compared to other intersections such as the north side of the Tech Parkway/Rock Creek Drive intersection. What is driving the design for an enhanced crosswalk in this location? Resolved 1 Marc Virata 02/19/2008 13 General [2/19/08] Please be aware that the additional width of Technology Parkway beyond the standard collector width is not reimbursable through Street Oversizing. Is the median shown on Technology Parkway intended to have landscaping? If so, we will look to have language in the development agreement regarding maintenance responsibilities (which will not be the City). Resolved 1 Marc Virata 02/19/2008 14 Water/Wastewater [2/19/08] General water main layout is okay for preliminary. Valving, fittings, etc. will be reviewed at final when detailed notes and information have been added. Resolved 1 Roger Buffington 02/19/2008 15 Construction Drawings [5/6/08] Please remove the reference to "plus added median" below the typical cross section on Sheet C-003. Is the use of the broken yellow line for the inside of the reversible lane ideal given that there are no turning movements currently to necessitate entering the center lane? [2/19/08] With the median on Technology Parkway intended to have landscaping per C-003 then additional information at the time of final will be required, such as landscaping plan, subdrain systems, etc. Active 1 Marc Virata 02/19/2008 16 Water/Wastewater [5/8/08] [2/19/08] Information pertaining to water service size is conflicting in various spots. Active 1 Roger Buffington 02/19/2008 17 Water/Wastewater [2/19/08] Did PFA require both FH's on Lot 2? Resolved 1 Roger Buffington 02/19/2008 18 Easements [2/19/08] Please provide a drainage easement by separate document for the off-site pond. Active 1 Basil Hamdan 02/19/2008 3/7/2011 Page 3 Project: HARMONY TECH PARK, 3RD FILING, CUSTOM BLENDING PDP - TYPE I AND FINAL PLANS ID Topic Issue Status Round Comment By Initial Date 19 Drainage Report [2/19/08] Please provide a written explanation in the report for the overall drainage design. Overall drainage report could be broken out into a separate report. Active 1 Basil Hamdan 02/19/2008 20 Utility Plans [2/19/08] The existing stub in Lady Moon Drive is being replaced, this will cause a street cut for a new street with associated fees. Can the exiting stub be used or is it at the wrong elevation ? If not please show extent of street cut. Please call out on the plans all the disturbed areas to be re-vegetated. Provide a plug detail for the storm sewer stubs. Please include a hydrology summary table on drainage plan and an erosion control sequence schedule on the erosion control plan. At final please show all spillway locations for detention ponds and provide details for the spillways as well as for the water quality outlets. Active 1 Basil Hamdan 02/19/2008 21 Fire [2/20/08] REQUIRED ACCESS: A fire lane is required. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements:  Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites.  Have appropriate maintenance agreements that are legally binding and enforceable.  Be designated on the plat as an Emergency Access Easement.  Maintain the required minimum width of 20 feet throughout the length of the fire lane. If a fire lane cannot be provided, the building shall be fire sprinklered. NOTE: When the structure is expanded in the future and the entire loop drive is paved, PFA likely will require that the fire lane be "filled in" throughout the entire loop. 97UFC 901.2.2.1; 901.3; 901.4.2; 902.2.1 Active 1 Carie Dann 02/20/2008 3/7/2011 Page 4 Project: HARMONY TECH PARK, 3RD FILING, CUSTOM BLENDING PDP - TYPE I AND FINAL PLANS ID Topic Issue Status Round Comment By Initial Date 22 Fire [2/20/08] ADDRESS NUMERALS: Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6 inch numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable).97UFC901.4.4 Active 1 Carie Dann 02/20/2008 23 Fire [2/20/08] WATER SUPPLY: Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not farther than 300 feet to the building, on 600-foot centers thereafter; residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not farther than 400 feet to the building, on 800-foot centers thereafter; residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not farther than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 97UFC 901.2.2.2 Active 1 Carie Dann 02/20/2008 24 Fire [2/20/08] SPRINKLER REQUIREMENTS: This proposed building shall be equipped with approved, automatic fire-sprinkler systems. Active 1 Carie Dann 02/20/2008 25 Fire [2/20/08] FIRE LINE REQUIREMENT: Buildings that are required to be fire sprinklered shall have a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. Active 1 Carie Dann 02/20/2008 26 Fire [2/20/08] FIRE DEPARTMENT CONNECTION: Fire department connections shall be installed on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. If possible, a fire hydrant shall be located within 100 feet of the FDC. PFA Bureau Policy Active 1 Carie Dann 02/20/2008 27 Fire [2/20/08] KNOX BOX REQUIRED: Poudre Fire Authority requires a “Knox Box” to be mounted on the front of every new building equipped with a required fire sprinkler system or fire alarm system. 97UFC 902.4; PFA BUREAU POLICY 88-20 Active 1 Carie Dann 02/20/2008 3/7/2011 Page 5 Project: HARMONY TECH PARK, 3RD FILING, CUSTOM BLENDING PDP - TYPE I AND FINAL PLANS ID Topic Issue Status Round Comment By Initial Date 28 Fire [2/20/08] COMMERCIAL COOKING FIRE EXTINGUISHING SYSTEM: An approved fire-protection system shall be installed in hood-and-duct locations where grease-laden vapors are produced from cooking operations. A permit and plan review is required by the Poudre Fire Authority for the installation of required hood-and-duct fire extinguishing systems. Two sets of plans, along with an application, are required to be submitted to the Fire Prevention Bureau at 102 Remington St. 97UFC 1006.1; 1006.2.1 Active 1 Carie Dann 02/20/2008 29 Fire [2/20/08] HMIA: Thank you for submittal of Hazardous Materials Impact Analysis. Active 1 Carie Dann 02/20/2008 30 Fire [2/20/08] . Active 1 Carie Dann 02/20/2008 31 Construction Drawings [2/20/08] The storm pipe crossing Technology Parkway on either side of the inlets may have a cover issue. Please look at achieving additional depth over the pipe to ensure no cover concerns. Resolved 1 Marc Virata 02/20/2008 32 Construction Drawings [5/6/08] The applicant's response is fine, though interestingly, I'm now realizing that west of Technology Parkway may not necessarily be a public street. Maybe a note on the construction plan should be provided indicating that Precision Drive may or may not develop as a public street west of Technology Parkway. Information shown for reference only. [2/20/08] For the future Precision Drive section please provide horizontal curve data. Active 1 Marc Virata 02/20/2008 33 Construction Drawings [5/6/08] See response to #32. [2/20/08] For the future Precision Drive section, please clarify the profile view information, the lines aren’t apparent as which might be proposed, existing, or other. Active 1 Marc Virata 02/20/2008 34 Construction Drawings [2/20/08] The storm pipe crossing Precision Drive on either side of the inlets may have a cover issue. Please look at achieving additional depth over the pipe to ensure no cover concerns. Resolved 1 Marc Virata 02/20/2008 35 General [2/20/08] I'm understanding that entitlement will only occur for the Custom Blending lot and that the remainder of the lots in the plat will be subject to their own project development plans and associated development agreements. Resolved 1 Marc Virata 02/20/2008 3/7/2011 Page 6 Project: HARMONY TECH PARK, 3RD FILING, CUSTOM BLENDING PDP - TYPE I AND FINAL PLANS ID Topic Issue Status Round Comment By Initial Date 36 General [2/20/08] Letters of intent should be provided from the property owner west of Technology Parkway where the offsite detention occurs. Resolved 1 Marc Virata 02/20/2008 37 Plat [5/7/08] Technical Services has the following revised comments: 1. Boundary and legal close but have minor differences. 2. Remove all references to Cambridge Avenue. [2/20/08] Technical Services has the following comments: 1. No north arrow and scale plat. 2. Plat closes, legal does not match plat at curve C7. Area is good. 3. Show how all the adjoining streets were dedicated. 4. Minor line over text issues. 5. Looks good as a preliminary plat. 6. Who own and maintains Tract A. Active 1 Marc Virata 02/20/2008 38 Plat [2/22/08] Please correct the title on the first page of the plat (remove "Center" and replace with "Park"). Resolved 1 Marc Virata 02/22/2008 39 Pond Maintenance [2/22/08] Since the pond will be a joint maintenance area, a maintenance agreement with the master property owner will be needed prior to final plan approval. Active 1 Basil Hamdan 02/22/2008 40 Traffic [2/24/08] Please define the cross hatched area on the median ends, sheet 13/16. Active 1 Ward Stanford 02/24/2008 41 Traffic [2/24/08] Please provide full dimensioning and signage on the S&S plan. Active 1 Ward Stanford 02/24/2008 42 Traffic [2/24/08] Please provide all existing lane striping and configuration at the Tech Prkwy & Rock Crk, and Lady Moon & Precision intersections. Active 1 Ward Stanford 02/24/2008 43 Traffic [2/24/08] The TIS indicates that the East bound left turn (EbL) at Lady Moon and Harmony will be LOS F due to short term background growth. Using the TIS's volumes and PHF in our current Harmony timing plan, the LOS is at D or E depending on the evaluation method. Therefore the LOS is acceptable. Active 1 Ward Stanford 02/24/2008 44 General [5/2/08] Please note that the Engineering Development Review Manager has determined that there is $300 owed in TDR Fees from the PDP. Active 2 Marc Virata 05/02/2008 3/7/2011 Page 7 Project: HARMONY TECH PARK, 3RD FILING, CUSTOM BLENDING PDP - TYPE I AND FINAL PLANS ID Topic Issue Status Round Comment By Initial Date 45 Detention Pond Landscaping [5/6/08] Thank you for providing adequate landscaping for the detention pond on Tract A. The lower portion of the pond is to be planted with a wetland seed mix, will there be sufficient water in this pond to sustain wetland vegetation ? If not what would be done to address that. Active 2 Basil Hamdan 05/06/2008 46 Plat [5/7/08] The "sight visibility easement" specified on the plat and other documents should be called out as a "sight distance easement" on the various documents. In addition, please provide our standard sight distance easement language on the plat. Active 2 Marc Virata 05/07/2008 47 Construction Drawings [5/7/08] Please update the details in LCUASS, many of the details are not the current version. Active 2 Marc Virata 05/07/2008 48 Construction Drawings [5/7/08] The typical road sections sheet seems to have the Precision Drive cross section shown incorrectly at the future sidewalk would be in the 11' parkway delineation. Active 2 Marc Virata 05/07/2008 49 General [5/7/08] As a heads-up, the additional width in Technology Parkway that encompasses the center turn lane which was previously a median, is not reimbursable from street oversizing. Active 2 Marc Virata 05/07/2008 50 Utility Plans [5/7/08] Why is the storm drainage being discharged into the pond through a subdrain system and a level spreader ? Active 2 Basil Hamdan 05/07/2008 51 Construction Drawings [5/7/08] Please add additional spot elevations at the PI per LCUASS 7-28. Active 2 Marc Virata 05/07/2008 52 Construction Drawings [5/7/08] The use of a cross pan at the high point of a flowline (Tech Parkway and Precision) is odd and technically not to standard. Can it just be eliminated? Perhaps in general it might be better not to build the curb return at the west leg of this intersection since it may not be a public street or a street for that matter with future development. Active 2 Marc Virata 05/07/2008 53 Water/Wastewater [5/8/08] Water main from Rock Creek to Precision to be 24". Active 2 Roger Buffington 05/08/2008 54 Water/Wastewater [5/8/08] Add 24" butterfly valve at point of connection near Rock Creek. Active 2 Roger Buffington 05/08/2008 3/7/2011 Page 8 Project: HARMONY TECH PARK, 3RD FILING, CUSTOM BLENDING PDP - TYPE I AND FINAL PLANS ID Topic Issue Status Round Comment By Initial Date 55 Water/Wastewater [5/8/08] Use joint restraint for the water main lowerings rather than thrust and gravity blocks. Provide calc's on the required restrained lengths on each side of the lowerings and label clearly on the plans. Add a note (as outlined in the redlines) regarding MEGALUGS or pre-approved equal. Active 2 Roger Buffington 05/08/2008 56 Water/Wastewater [5/8/08] Label lengths of pipe between valves, fittings, etc, etc. Active 2 Roger Buffington 05/08/2008 57 Water/Wastewater [5/8/08] Add butterfly valve, air release valve and tracer wire (2) details. Active 2 Roger Buffington 05/08/2008 58 Water/Wastewater [5/8/08] See redlined plans for other comments. Active 2 Roger Buffington 05/08/2008 59 Plat [5/14/08] n order to promote compliance with Sections 12-120, 12-121 and 12-122 of the City Code related to Resource Conservation, a note must be placed on the Project Development Plan (PDP) site plan alerting future Propert Owners Associations of private property owner rights to use resource saving devices or techniques under certain conditions. Said note shall read: Private Conditions, Covenants, and Restrictions (CC&R's), or any other private restrictive covenant imposed on landowners within the development , may not be created or enforced which has the effect of prohibiting or limiting the installation of xeriscape landscaping, solar/photo-voltaic collectors (if mounted flush upon any established roof line), clothes lines (if located in back yards), odor-controlled compost bins, or which has the effect of requiring that a portion of any individual lot be planted in turf grass. Active 2 Dana Leavitt 05/14/2008 3/7/2011 Page 9