ID Topic Issue Status Round Comment By Initial Date
1 zoning [2/3/09] no comments Active 1 Jenny Nuckols 02/03/2009
2 zoning [2/3/09] A drainage easement exists where the building is desired to be
placed. A structure can not be placed within an easement. In order for the
building to be placed as shown the area underneath the building will need to
be vacated.
I would suggest checking with stormwater to determine if a portion of the
easement can be vacated before submitting a request to do so. Engineering
charges a $400 processing fee for vacating an easement. The applicant is
responsible for providing a legal description (which is required to be prepared
by a licensed surveyor) and the fees for filing fees. Please contact Sheri
Langenberger at 221-6605 for an informational sheet on the vacation
process.
Active 1 Sheri Langenberger 02/03/2009
3 zoning [2/17/09] Existing transformer is 120/208 volt three phase. Active 1 Alan Rutz 02/17/2009
4 zoning [2/17/09] Electric meter must be placed on the outside of the enclosure Active 1 Alan Rutz 02/17/2009
5 zoning [2/17/09] Contact Light and Power with load requirements and billing data. Active 1 Alan Rutz 02/17/2009
6 Water/Wastewater [2/18/09] There are existing water/sewer lines in the drive adjacent to the
proposed building/tower site. The water line extends east to Centennial. Add
the location of these lines (based on field locates) to the site plan and
maintain 10 feet of separation between the proposed facilities (including the
underground electrical service) and the water/sewer lines (including the water
services extending south of the water main).
Active 1 Roger Buffington 02/18/2009
7 Stormwater [2/19/09] The blanket drainage easement will need to be vacated for the
limits of the structure.
Active 1 Wes Lamarque 02/19/2009
3/7/2011 Page 1
Project: Poudre Valley Plaza / AT&T Wireless Telecommunication Facility (WTF) PDP - Type I
ID Topic Issue Status Round Comment By Initial Date
8 Stormwater [2/19/09] Drainage currently sheet flows through this area to the northeast.
Drainage should be diverted around this structure. This can be done with
curb & gutter. Please show on the site plan how drainage will be directed
around the structure.
Active 1 Wes Lamarque 02/19/2009
9 Fire PFA has no comments or concerns at this time. Active 1 Carie Dann 02/19/2009
10 General [2/20/09] Please revise the Landscape & Elevations Plans to show the
existing trees and shrubs in the island at the west end of this facility.
Active 1 Steve Olt 02/20/2009
11 General [2/20/09] Please add West to Horsetooth Road on the Site Plan for the entire
Poudre Valley Plaza center. Please label Century Drive, along the east side
of the center, on the same Site Plan.
Active 1 Steve Olt 02/20/2009
12 General [2/20/09] Please put "Poudre Valley Plaza" in the middle of the center on the
overall Site Plan.
Active 1 Steve Olt 02/20/2009
13 General [2/20/09] Rick Lee of the Building Department is forwarding to the applicant a
copy of the 2008 Commercial / Multi-Family Codes & Standards that will
apply to this development request.
Active 1 Steve Olt 02/20/2009
14 General [2/20/09] Technical Services indicated that a portion of theTitle Block is
missing on the 11" x 17" drawings. Also, the legal description for the Poudre
Valley Plaza center, and possibly the portion of the center where this WTF
will be located, must be added to the Overall Site Plan.
Active 1 Steve Olt 02/20/2009
15 General [2/20/09] Signature blocks for the Owner's Certification, a Notary Public (to
notarize the owner's signature), and the Director of Planning must be added
to the overall Site Plan.
Active 1 Steve Olt 02/20/2009
16 General [5/13/09] no comments.
[2/20/09] No comments.
Active 1 Dana Leavitt 02/20/2009