HomeMy WebLinkAboutCAMBRIDGE LOFTS APARTMENTS PDP & FC - 06-03C D - CORRESPONDENCE -Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) Project Development Plan REQUEST TO CONSTRUCT 17 ADDITIONAL DWELLING UNITS (5 2-BEDROOM AND 12 3-BEDROOM) AND 3,100 S.F. OF NON-RESIDENTIAL SPACE TO THE EXISTING CAMBRIDGE HOUSE APARTMENTS. THE PROJECT INCLUDES TWO SEPARATE BUILDINGS. THE EXISTING POOL HOUSE WILL BE CONVERTED TO 5 TWO-BEDROOM UNITS. ADDITIONALLY, A NEW 5-STORY BUILDING WILL BE CONSTRUCTED ON THE EAST EDGE OF THE PROPERTY, ABUTTING SOUTH SHIELDS STREET, WITH GROUND FLOOR NON-RESIDENTIAL SPACE AND 12 THREE-BEDROOM APARTMENT UNITS ON THE SECOND THROUGH FIFTH STORIES. Project Type: Project Desc: File ID: 06-03C/D Planner: Steve Olt DMS Project Num: CP031474 ID Topic Issue Status Round Comment By Initial Date 1 Light & Power [4/28/04] [12/12/03] The developer will need to coordinate power requirements, transformer locations, and electric development charges with Light & Power Engineering (970)221-6700. Active 1 Doug Martine 12/12/2003 2 Light & Power [4/28/04] [12/12/03] The existing transformers serving Cambridge apartments will need to be relocated. The existing wood fence enclosure around these transformers is not Light & Power approved anyway. Active 1 Doug Martine 12/12/2003 3 General [12/18/03] .REQUIRED ACCESS: A fire lane is required. The fire lane shall be visible by painting and signage, and maintained unobstructed. The criteria for a required fire lane contain several conditions that must be met. 1. Buildings three stories or more in height must have access to a 30 foot unobstructed access roadway on at least (1) one side for aerial operations. 2. Inside turning radius shall be 25 feet and outside turning radius shall be 50 feet. 3. Compacted road base shall be used during the construction phase only. The permanent fire lane shall consist of asphalt or concrete and shall be required to support 40 tons 4. The fire lane shall be platted as an “Emergency Access Easement” on the final plat. 1997 UFC 901.2.2.1; 901.3; 901.4.2; FCLUC; PFA Policy 85-5 (B) Active 1 Michael Chavez 12/18/2003 3/7/2011 Page 1 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 4 General [12/18/03] ADDRESS NUMERALS: Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6 inch numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). NOTE: If addressed off 1113 W. Plum St., an addressing pattern that coincides with existing buildings shall be maintained. 1997 UFC 901.4.4 Active 1 Michael Chavez 12/18/2003 5 General [12/18/03] WATER SUPPLY: Commercial No commercial building can be greater then 300 feet from a fire hydrant. Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must be capable of delivering 1500 gallons of water per minute at a residual pressure of 20 psi. 1997 UFC 901.2.2.2 Active 1 Michael Chavez 12/18/2003 6 General [12/18/03] SPRINKLER REQUIREMENTS: Buildings that are three or more stories in height shall be fire sprinklered. There shall be a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. 1997 UFC 1003.2.9; 902.2.1 Active 1 Michael Chavez 12/18/2003 7 General [12/18/03] FIRE ALARM REQUIREMENTS: A fire alarm system is required for this proposed project. 1997 UFC 1007.2.9.1.1 Active 1 Michael Chavez 12/18/2003 8 General [12/18/03] KNOX BOX: Poudre Fire Authority requires a “Knox Box” to be mounted on the front of every new building equipped with a required fire sprinkler system or fire alarm system. 1997 UFC 902.4; PFA POLICY 88-20 Active 1 Michael Chavez 12/18/2003 9 Zoning [7/6/04] [4/28/04] 7-7-04 - comment still applies [12/19/03] The tree cut-outs don't count as landscape dislands and don't break up the parking aisles into 15 or fewer spaces in a row. Please review - also it creates 2 non-conforming spaces that are too short - but people will still attempt to park in them - but not be able to pull all the way forward. Resolved 1 Jenny Nuckols 12/19/2003 3/7/2011 Page 2 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 10 Zoning [4/28/04] [12/19/03] North end parking aisle shows 16 spaces, southe nd shows 17, only 15 in a row without an intervening island are allowed Active 1 Jenny Nuckols 12/19/2003 11 Zoning [12/19/03] Would prefer the site plan to only show site itmes, not landscape items - the landscaping is/should be shown on the landscape plan Resolved 1 Jenny Nuckols 12/19/2003 12 Zoning [4/28/04] [12/19/03] Plant Notes #4 - add ot working - value of landscpaing "and installation" Resolved 1 Jenny Nuckols 12/19/2003 13 Zoning [12/19/03] On the south end where the diamond cut-out for the tree is located there is only 2.5 ft og sidewalk - check with engineering on their standards Resolved 1 Jenny Nuckols 12/19/2003 14 Zoning [7/6/04] Same comment [12/19/03] Label building envelope, footprint, dimensions, distance to property lines Active 1 Jenny Nuckols 12/19/2003 15 General [12/23/03] Project title needs to be consistent between the plan sets. All sets should read "Cambridge House Lofts" or whatever the project title is that you decide on. Resolved 1 Susan Joy 12/23/2003 16 Existing Site Plan [12/23/03] Remove landscaping. Resolved 1 Susan Joy 12/23/2003 17 Existing Site Plan [12/23/03] See appendix E6 for scanability requirements. Correct all overlapping labeling and increase the font size to meet the minimum. Resolved 1 Susan Joy 12/23/2003 18 Existing Site Plan [12/23/03] Sidewalk is shown between the two driveway entrances on Plum but no sidewalk to the east and west of those same drives. Is there any existing out there? If so, please show. If not, why not? Resolved 1 Susan Joy 12/23/2003 19 Existing Site Plan [12/23/03] Dimension Scott Avenue ROW, both existing and proposed. Resolved 1 Susan Joy 12/23/2003 20 Site Plan [12/23/03] Show all easements, label and dimension. Resolved 1 Susan Joy 12/23/2003 3/7/2011 Page 3 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 21 Site Plan [12/23/03] Remove landscaping. Resolved 1 Susan Joy 12/23/2003 22 Site Plan [12/23/03] Remove contours. Resolved 1 Susan Joy 12/23/2003 23 Site Plan [5/10/04] Repeat comment. The site plan is not scannable and will not be approved until it meets the criteria set forth in appendix E6. The font is so small in some places that I cannot read it or review it. More comments could follow when it becomes legible. [12/23/03] Correct all overlapping labeling and increase font size to meet the minimum requirement. See appendix E6 for additional scanability requirements. Resolved 1 Susan Joy 12/23/2003 24 Site Plan [12/23/03] Dimension Scott Avenue ROW, existing and proposed. Resolved 1 Susan Joy 12/23/2003 25 Site Plan [12/23/03] Please contact Tom Reiff in Transportation Planning regarding the sidewalk along Plum street east and west of the existing drive entrances as well as the sidewalk along the southern property boundary. The proposed tree well narrows the 6' sidewalk down to 2.5' and does not meet our minimum standards. Resolved 1 Susan Joy 12/23/2003 26 Landscape Plan [7/13/04] Please correct the easement along Plum to be a 24' Public Access and Utility Easement (see utility and plat plans) and show the emergency access easement. [5/10/04] Repeat comment. [12/23/03] Show all utilities and easements (dimensioned and labeled). Active 1 Susan Joy 12/23/2003 27 Landscape Plan [12/23/03] Remove contours. Resolved 1 Susan Joy 12/23/2003 28 Landscape Plan [5/10/04] Repeat comment. The landscape plan will not be approved until all requirements in Appendix E6 have been met. [12/23/03] See appendix E6 for scanability requirements. Resolved 1 Susan Joy 12/23/2003 29 Plat [5/10/04] Repeat comment. Corrections required, see redlines. [12/23/03] Most of the plat language shown is incorrect. Please see the attached for the correct plat language. Resolved 1 Susan Joy 12/23/2003 3/7/2011 Page 4 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 30 Plat [12/23/03] Spell out all abbreviated easement labels. Resolved 1 Susan Joy 12/23/2003 31 Plat [5/10/04] Repeat comment. Labeled incorrectly. [12/23/03] Change the "Pedestrian Access Easement" along Plum Street to read "Public Access Easement". Resolved 1 Susan Joy 12/23/2003 32 Plat [5/10/04] Repeat comment. Labeled incorrectly and missing width dimensions. Also, the emergency access lane is shown extending into the parking stalls and over the curb on the utility plans. This, for obvious reasons, will not work. Please locate the emergency access lanes out of these areas and in an area free of all obstructions. [12/23/03] Dedicate the fire lane on the plat, label as "Emergency Access Easement". Resolved 1 Susan Joy 12/23/2003 33 Plat [5/18/04] [12/23/03] Provide two ties to aliquot corners. Resolved 1 Susan Joy 12/23/2003 34 Utility Plans [12/23/03] Correct the preamble title to read "Utility Plans for …" Resolved 1 Susan Joy 12/23/2003 35 Utility Plans [5/10/04] Correction required, see redlines. [12/23/03] Provide two project bench marks referencing the City's datum. Resolved 1 Susan Joy 12/23/2003 36 Utility Plans [12/23/03] See Bob Zakely for revegatation methods and specific notes required on the plans. Resolved 1 Susan Joy 12/23/2003 37 Utility Plans [5/10/04] Because you've added a horizontal control sheet, you can put all the dimensioning on there and just show the emergency access easement on all the other sheets (it should help keep your sheets legible). Make sure that the EAE is located in an area free of all obstructions (parking stalls, curb and gutter, etc). [12/23/03] Show, dimension, and label the fire lane required by PFA. Resolved 1 Susan Joy 12/23/2003 3/7/2011 Page 5 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 38 Utility Plans [12/23/03] See the attached checklist for other comments. The highlighted items were reviewed with the first round of review. The remaining items are reviewed after hearing and in the final compliance review. Resolved 1 Susan Joy 12/23/2003 39 Utility Plans [12/23/03] Sheet 3, Add the street cut note: Limits of street cut are approximate. Final limits are to be determined in the field by the City Engineering Inspector. All repairs to be in accordance with City street repair standards. Resolved 1 Susan Joy 12/23/2003 40 Utility Plans [12/23/03] Provide details: 701, 702, 707, 1601, 1602, 1606 Resolved 1 Susan Joy 12/23/2003 41 General [5/18/04] It was agreed that a Public Access Easement would be dedicated to the back of walk in lieu of dedicating the additional ROW at this time. Please dedicate this easement on the plat. [12/23/03] This project is responsible for dedicating their half of the current local street width (51' total) and for the design and construction of Scott Avenue. There is currently 20' of ROW for Scott Avenue. That means that this project needs to dedicate an additional 15.5', or (51-20)/2. However, you may dedicate the additional width as a Public Access, Utility, and Drainage Easement instead so that the applicant still retains the currect use of the property as currently shown. In addition, this project is responsible for dedicating their half of a minor collector with parking along Plum. There is currently 40' of ROW and a total of 76' is needed. That means that this project must dedicate an additional 18' of ROW on Plum. They do NOT need to dedicate the utility easement along Plum. No additional ROW along Shields is required. Resolved 1 Susan Joy 12/23/2003 42 Tree Preservation Standards [12/29/03] Contact Tim Buchanan, City Forester for an evaluation of existing trees to be removed. If trees are being mitigated then mitigation trees need to be shown and labeled on landscape plan. Limits of development (LOD), details showing protective fencing and tree protection notes are also needed in utility set. Notes may be obtained from the City Forester. L.U.C. 3.2.1(F), 3.2.1(G) Active 1 Doug Moore 12/29/2003 3/7/2011 Page 6 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 43 General [12/29/03] Lighting Plan needed. Recommend that ground access to stairwells be well lit, avoid landscape materials that provide concealment, provide openings - viewports - in stairwell design. Need specific type and location of plant materials. Active 1 Joseph Gerdom 12/29/2003 44 General [12/30/03] Parking stall dimensions must be in accordance with LCUASS, figure 19-7. I've included a comment from the modification submittal that came through in September of 2003: [9/25/03] Upon submittal of a PDP, parking stall dimensions must meet the minimum standards as shown in Chapter 19 of LCUASS. Please label and dimension all drive aisle widths as well as all parking stall lengths and widths so that we can determine whether or not the parking stalls meet minimum requirements. 12/31/3: A variance request must be submitted in accordance with LCUASS if the parking dimensions do not meet standards. Resolved 1 Susan Joy 12/30/2003 45 General [12/30/03] Use a tapping saddle to make the fire line connection to the existing water main. Label fire line as Ductile Iron Pipe (D.I.P.). Resolved 1 Jeff Hill 12/30/2003 46 General [12/30/03] Separate water and sewer services are required for each use (i.e. commercial verses residential). Resolved 1 Jeff Hill 12/30/2003 47 General [5/20/04] Curb stops must be with in a utility easement and the meter pit may not be located more than 2 feet from the curb stop. Provide flow calculation for the sizing of the proposed water service for the residential portion of this development. [12/30/03] Curb stop and meter pit may not be located in the sidewalk or any other traveled way. See site, landscape and utility plans for other comments. Resolved 1 Jeff Hill 12/30/2003 48 General [12/30/03] Provide a 10 foot utility easement on either side of the existing sanitary sewer main. Maintain 10 foot clear separation between the existing sanitary sewer main and any permanent structure (i.e. trash enclosure, canopies, etc.). Will existing sanitary sewer manhole covers need to be raised or lowered? If so, provide all detail necessary.) Provide a water tight manhole cover for the existing manhole which will be located in the proposed curb and gutter. Resolved 1 Jeff Hill 12/30/2003 3/7/2011 Page 7 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 49 General [12/30/03] Maintain the required landscape/utility separation distances on the landscape plans. See site, landscape and utility plans for other comments. Resolved 1 Jeff Hill 12/30/2003 50 General [12/31/03] A variance request will need to be submitted by a licensed engineer if the emergency access easement does not meet standards. [9/25/03] From the modification request: Upon submittal of a PDP, the fire lane must meet the minimum requirements as shown in 7.8 of LCUASS and the Emergency Access section 3.6.6 in the COFC Land Use Code. Such emergency access lanes must be in a dedicated emergency access easement (can be done by separate document). Please contact PFA to determine if such easements are required. Please label and dimension the width and inner/outer radii of the emergency access lane so that we can determine whether or not the lane meets minimum requirements. Resolved 1 Susan Joy 12/31/2003 51 Traffic Study [12/31/03] Please provide a copy of the TIS as one was not received by the Engineering Dept. with this submittal. Resolved 1 Susan Joy 12/31/2003 52 Landscape Plan [12/18/03] The tree cut-outs don't count as landscaped islands and son't break up the parking into rows of 15 or fewer spaces Active 1 Jenny Nuckols 12/31/2003 53 General [12/31/03] No comments. Active 1 Garold Smith 12/31/2003 54 Traffic Study [12/15/03] The TIS dated 12/08/03 is acceptable. No issues from Traffic Operations Active 1 Eric Bracke 12/31/2003 55 Drainage Stormwater is ready for hearing. Additional comments may follow during final plan submittal. Resolved 1 Wes Lamarque 01/01/2004 56 Drainage Please coordinate the landscape plan with the utility plans. Shrubs are proposed over the concrete pan. Resolved 1 Wes Lamarque 01/01/2004 57 Erosion/Sediment Control 1. Please provide required calculations to support plan and surety calculations at final plan review. 2. The site slopes west to east, yet there is no protection along Shields Street. What protection will be provided there to protect areas downstream? Resolved 1 Wes Lamarque 01/01/2004 3/7/2011 Page 8 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 58 General [1/8/04] The Conceptual Landscape Plan calls the project "Cambridge House PUD." The Existing Site Plan and the proposed Site Plan calls the project "Cambridge Lofts." The elevation sheet calls the project "Cambridge House Lofts." All sheets need to use the same name. Also, the project is a Project Development Plan, not a PUD. We have therefore entered the name in our system as "Cambridge Lofts Apartments PDP." Please change the title of all drawing sets, including civil engineering drawings to this name. If you don't like the name we chose, you can choose a different one. Let us know what you want the name to be and make sure all the drawing sheets say the new name. Active 1 Troy Jones 01/08/2004 59 Plat [1/8/04] The plat is not a minor subdivision. We don't do minor subdivisions anymore. The plat should also be titled "Cambridge Lofts Apartments PDP." Active 1 Troy Jones 01/08/2004 60 General [1/8/04] Shrubs are shown within an area shown on the utility plans to be a concrete channel at the southeast corner of the site. Please resolve this conflict. Active 1 Troy Jones 01/08/2004 61 General [1/8/04] Don't show any trees on the site plan, only show them on the landscape plan. This includes not showing existing trees. Active 1 Troy Jones 01/08/2004 62 General [1/8/04] Advance Planning, Current Planning and Transportation Planning all need to review a detail at a larger scale fo the sidewalk and landscape areas on the east and south sides of the new Shields Street building. As currently shown, it's just too small of a scale to get an understanding of what's exactly proposed. It's not clear what's proposed within the planting beds, and the paving patterns are a little confusing at this scale. Active 1 Troy Jones 01/08/2004 63 General [1/8/04] Along the northeastern corner of the site, extend a sidewalk along the street frontage. If the existing tree is in the way, it can be removed, because it is considered a nusiance species of tree. Tim Buchanan, the City Forester should be contacted first. Active 1 Troy Jones 01/08/2004 64 General [1/8/04] The new tree porposed along the south property line midway between the new building and the existing apartments is not considered to be feasible to have there because of the location of the sewer line in that vicinity. You should remove this tree from the plans. The landscape diamond should remain where shown, but have a shrub. Active 1 Troy Jones 01/08/2004 3/7/2011 Page 9 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 65 General [1/8/04] Scott Avenue is a public street directly west of the site. It is gravel and the right of way is only 25 feet wide. At some point in the long mid to long term future, Scott Avenue will likely be widened and improved by the creation of some sort of Special Improvement District or some other mechanism. Although such improvements would not likely happen anytime soon, such widening would impact the parking along the west edge of Cambridge House Apartments. If Scott Avenue were to have a right of way width in accordance with the local residential street standard, the right of way would need to be 51 feet wide. This would mean that an addition 15.5 feet would be needed from the Cambridge House apartments property to accomplish this. One potential solution staff is considering would be to have this project dedicate a 15.5 foot wide access easement along the western edge of the property. The conditions by which the City would exercise the use of this area would need to be carfully spelled out in the development agreement. It would also need to be clarified in the developent agreement that the loss of on-site parking as a result of Scott Street being built would need to be somehow accommodated by on-street parking, or some other solution that doesn't adversely affect Cambridge House Apartment. I'm in the process of coordinate schedules, we should meet on this issue next week. Active 1 Troy Jones 01/08/2004 66 General [1/8/04] The scale on the conceptual landscape plan and the site plan seems to be the same but one is labeled at 1"=20' and the other is labeled at 1"=30'. Please clarify. Active 1 Troy Jones 01/08/2004 67 General [1/8/04] Specify colors of materials on the elevations and bring in samples of the brick and concrete block. Active 1 Troy Jones 01/08/2004 68 General [1/8/04] We can tentatively plan to take the project to the Feburary 19th Planning and Zoning Board meeting, provided we come to an agreement on how best to deal with Scott Avenue. Active 1 Troy Jones 01/08/2004 69 General [1/8/04] OK. Active 1 Beth Sowder 01/08/2004 70 General [1/8/04] No comment. Active 1 Craig Foreman 01/08/2004 71 General [1/8/04] No Concerns. Active 1 Carl Jenkins 01/08/2004 3/7/2011 Page 10 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 72 General [1/8/04] Any relocation, cutoff's or installation of gas facilities will be at developers expense. Active 1 Len Hilderbrand 01/08/2004 73 General [1/8/04] No trees planted with in 4' of gas lines. (existing or future mains, services, etc.) Active 1 Len Hilderbrand 01/08/2004 74 General [1/8/04] Plat shows wrong legals for area/ 67W Should be/ 15. 7N. 69W Active 1 Len Hilderbrand 01/08/2004 75 General [1/8/04] Water Conservation has no comments. Active 1 Troy Jones 01/08/2004 76 General [1/8/04] See the attached comment sheet from Building Inspection. Active 1 Troy Jones 01/08/2004 77 Plat [1/9/04] All of the plat language is wrong. Please see the attached for the correct language. Resolved 1 Susan Joy 01/09/2004 78 Plat [1/9/04] Correct the project title. Resolved 1 Susan Joy 01/09/2004 79 Plat [1/9/04] Spell out all abbreviations. Resolved 1 Susan Joy 01/09/2004 80 Plat [1/9/04] Dedicate the emergency access lane required by PFA. Resolved 1 Susan Joy 01/09/2004 81 Plat [1/9/04] See comments under General that effect the plat. See redlines. Resolved 1 Susan Joy 01/09/2004 82 General [1/9/04] See attached redlines from Current Planning. Active 1 Troy Jones 01/09/2004 83 General [1/9/04] The sidewalk along the south side of the new building must be a minimum of 6 feet wide [LUC 3.2.2(C)(5)]. Active 1 Troy Jones 01/09/2004 84 Transportation [7/13/04] The additional ramps along the walkway connecting Shields St. to the existing Cambridge House apartment complex are still not shown on the utility plans. Please correct. [5/18/04] A few additional access ramps still need to be added to the plans (see red lines). [1/12/04] Please include all access ramps associated with sidewalks on all the plan sets including the utility and site plans. Active 1 Tom Reiff 01/12/2004 3/7/2011 Page 11 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 85 Transportation [5/18/04] [1/12/04] Plum Street is classified as a collector on the Master Street Plan. Please dedicate your half of the 76 foot right of way. This should be measured from the centerline of Plum Street. Resolved 1 Tom Reiff 01/12/2004 86 Transportation [5/18/04] Please remove the proposed new vertical v-shaped curbs shown on the utility plans along the Scott R.O.W. These verical curbs were intended for landscaping that is not longer required. [1/12/04] Given the planned future connection of Scott Avenue to W. Elizabeth, please replace the proposed shade trees along Scott Avenue with ornamental trees. Resolved 1 Tom Reiff 01/12/2004 87 Transportation [7/13/04] Utilitiy plans need to clearing show how the sidewalks changes along Plum Street will connect to the existing sidewalk. [5/18/04] There are minor discrepancies between the utility plans and the site and landscape plans. Please clean up the Plum Street sidewalk configuration between the plan sets. Keep in mind that the sidewalk needs to continue to the edge of the property line and connect to the existing sidewalk. [1/12/04] The sidewalk along Plum Street will need to continue to the edge of the property line to the east. Please include a sidewalk that crosses the driveway to the eastern property line (see red lines for alignment). Active 1 Tom Reiff 01/12/2004 88 Transportation [1/12/04] Please provide an enlarged section for the Shields Street sidewalk and landscaped frontage. Also the sidewalk on the south side of the building should be a minimum of 6 feet in width to accommodate the high pedestrian traffic. Resolved 1 Tom Reiff 01/12/2004 89 Zoning [4/28/04] Please remove the small print referencing landscaping on the site plan. Does not need to be on site plan and is too small to read anyway. Active 2 Jenny Nuckols 04/28/2004 90 Site Plan [7/13/04] Please correct the easement along Plum to be a 24' Public Access and Utility Easement (see utility and plat plans). [5/10/04] Site plan does not match the utility plans. Active 2 Susan Joy 05/10/2004 3/7/2011 Page 12 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 91 Landscape Plan [5/10/04] The landscape plan does not match the utility plan. Resolved 2 Susan Joy 05/10/2004 92 Utility Plans [7/14/04] Correction required to the emergency access easement variance. The min widths and radii were not met at the "pinch" point and it needs to be reworded to reflect that. [5/10/04] Sheet 2 - please be a little more specific on the variance granted in line 48. Include the section, the actual requirement, and then the variance itself. Also, include the variance to the emergency access easement miminum widths and radii granted by PFA. Active 2 Susan Joy 05/10/2004 93 Utility Plans [5/10/04] Sheet 3 - Label all easements with what the easement is for (Utility, Emergency Access Easement, etc). Resolved 2 Susan Joy 05/10/2004 94 Utility Plans [5/10/04] Sheet 3 - Correct all overlapped labeling. Remove the landscaping. Resolved 2 Susan Joy 05/10/2004 95 Utility Plans [5/10/04] Sheet 4 - is unscannable. Remove landscaping. Resolved 2 Susan Joy 05/10/2004 96 Landscape Plan [5/10/04] Planters along Shields street must be located outside the existing utility easement or are these tree grates? Please label accordingly. Resolved 2 Susan Joy 05/10/2004 97 Utility Plans [5/10/04] Sheet 5 - Remove the landscaping. Block out background around text. Correct a misspelled word. Resolved 2 Susan Joy 05/10/2004 98 Utility Plans [5/10/04] Cover Sheet - Please provide the name, address, and phone number of the Owner and/or Developer. Resolved 2 Susan Joy 05/10/2004 99 Utility Plans [5/10/04] Sheet 4 - Please provide finish grade elevations for all lot corners and finish floors/top of foundation of all buildings for all lots. Resolved 2 Susan Joy 05/10/2004 100 Utility Plans [5/10/04] Sheet 4 - Please provide the statement: The top of foundation elevations shown are the mimimum elevations required for protection from the 100-year storm. Resolved 2 Susan Joy 05/10/2004 101 Utility Plans Please provide site specific details for the sidewalk chase and concrete channel. See redlined plans. Also, provide a valley pan detail. Resolved 2 Wes Lamarque 05/17/2004 102 Utility Plans Please provide a F.F. elevation for the proposed building. Resolved 2 Wes Lamarque 05/17/2004 3/7/2011 Page 13 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 103 Utility Plans 1. Please provide a project schedule indicating when various BMP’s will be installed within the framework of the construction. You don’t need to use specific dates (months), you can just use project phases, etc. Resolved 2 Wes Lamarque 05/17/2004 104 Utility Plans [5/18/04] Parking lot lighting levels are below required 1.0fc. Also, important in making revisions - evaluate location of plant materials. Need photometrics for area next to stairs. Active 2 Joseph Gerdom 05/18/2004 106 Plat [5/18/04] Instead of having a 15' utility easement and 24' public access easement along Plum, just make one combined 24' Public Access and Utility Easement. Resolved 2 Susan Joy 05/18/2004 108 Plat [5/18/04] Label Scott Avenue as 25' ROW. Resolved 2 Susan Joy 05/18/2004 109 Plat [7/13/04] [5/18/04] From Technical Services: Boundary and legal close. Active 2 Susan Joy 05/18/2004 110 Plat [5/18/04] From Technical Services: The need for a block in a 2 lot subdivision is unnecessary. Resolved 2 Susan Joy 05/18/2004 111 Plat [7/14/04] [5/21/04] Will there be any restaurants in the building? If so, provide grease interceptor. Active 2 Roger Buffington 05/21/2004 112 Landscape Plan [5/24/04] The (Final Compliance) Landscape Plan does not necessarily satisfy the City Forester's requirement for tree mitigation for the loss of 4 existing significant trees. Based on the previous Landscape Plan, Tim Buchanan stated that 12 new trees need to be upsized to 3.0" caliper for adequate mitigation. The current plan shows 7 new deciduous trees to be upsized to 3.0" caliper and 5 new ornamental trees to be upsized to 2.5" caliper. Mr. Buchanan must determine if the current plan satisfies the Land Use Code requirement for tree mitigation. Active 2 Steve Olt 05/24/2004 113 Landscape Plan [5/24/04] The proposed "Fallgold" Ash at the northwest corner of the site is too close to the west edge of the driveway into the development. It must be a minimum of 8' from edge of driveway. The "Fallgold" Ash is not shown in the Plant Legend. Also, this proposed tree may be in conflict with a future Scott Avenue entension. Active 2 Steve Olt 05/24/2004 3/7/2011 Page 14 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 114 Landscape Plan [5/24/04] There are 3 Ash trees shown in the planting island just west of the existing church. The assumption is that they are to be "Summit" Ash and should be labeled as such on the plan. Active 2 Steve Olt 05/24/2004 115 Landscape Plan [5/24/04] Plan Note #4 must be revised to include the reference to 125% of the "materials & labor" for the landscaping. Active 2 Steve Olt 05/24/2004 116 Landscape Plan [5/24/04] It is difficult to follow the alignment of the existing (proposed?) sidewalk along the south side of West Plum Street, north of the 3 buildings in this development. Active 2 Steve Olt 05/24/2004 117 Landscape Plan [5/24/04] Please add a scale on this sheet for the Full Landscape Plan. It should be, presumably, 1" = 30.0'. Active 2 Steve Olt 05/24/2004 118 Site Plan [5/24/04] On the Site Plan, eliminate the labeling for plant material around the new building. The plant material is not shown but the labeling still is. Active 2 Steve Olt 05/24/2004 119 Site Plan [5/24/04] Under the Land Use Statistics on the Site Plan, the Maximum Building Height is shown to be 56'-0". This is inconsistent with the Exterior Elevations Plan, which shows the building to be 58'-0" high. Active 2 Steve Olt 05/24/2004 120 Building Elevations [5/24/04] The Exterior Elevations Plan shows the building to be 58'-0" high. This is inconsistent with the Site Plan, which indicates a Maximum Building Height of 56'-0" under the Land Use Statistics. Active 2 Steve Olt 05/24/2004 121 Site Plan [5/24/04] The Planning & Zoning Certificate block is not needed on the Site Plan and should be removed. Active 2 Steve Olt 05/24/2004 122 Site Plan [5/25/04] There are numerous words misspelled in the General Notes on the Site Plan (please see red-lined plan). Active 2 Steve Olt 05/25/2004 123 Plat [7/13/04] Repeat from last round of redlines: What are all the extra leaders for? Active 3 Susan Joy 07/13/2004 124 Plat [7/13/04] From Technical Services: Typo in Legal, section 12 should be section 15 (see redlines). Active 3 Susan Joy 07/13/2004 125 General [7/13/04] Ready for mylars with the remaining items addressed (do not need to resubmit). Active 3 Susan Joy 07/13/2004 3/7/2011 Page 15 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 126 Drainage The F.F. elevation for the building needs to be 18-inches above the flowline of the gutter in Shields. This is required due to the flow depth allowed in an arterial street to be 18-inches in the 100-year storm. Resolved 3 Wes Lamarque 07/13/2004 127 Drainage Please change detail of 5-foot chase to have a 6-inch concrete support. See redlined plans. Resolved 3 Wes Lamarque 07/13/2004 128 Utility Plans [7/14/04] Check labeling of water services. A 1" water service is not adequate for 12 units. Active 3 Roger Buffington 07/14/2004 129 General [7/14/04] No issues. Active 3 Doug Moore 07/14/2004 130 General [7/21/04] The Current Planning Department is ready for mylars of the Site Plan, Landscape Plan, Building Elevations, and subdivision plat (3 sets, at least 1 with original signatures) to be submitted. Active 3 Steve Olt 07/21/2004 ID Topic Issue Status Round Comment By Initial Date 1 Light & Power [4/28/04] [12/12/03] The developer will need to coordinate power requirements, transformer locations, and electric development charges with Light & Power Engineering (970)221-6700. Active 1 Doug Martine 12/12/2003 2 Light & Power [4/28/04] [12/12/03] The existing transformers serving Cambridge apartments will need to be relocated. The existing wood fence enclosure around these transformers is not Light & Power approved anyway. Active 1 Doug Martine 12/12/2003 3/7/2011 Page 16 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 3 General [12/18/03] .REQUIRED ACCESS: A fire lane is required. The fire lane shall be visible by painting and signage, and maintained unobstructed. The criteria for a required fire lane contain several conditions that must be met. 1. Buildings three stories or more in height must have access to a 30 foot unobstructed access roadway on at least (1) one side for aerial operations. 2. Inside turning radius shall be 25 feet and outside turning radius shall be 50 feet. 3. Compacted road base shall be used during the construction phase only. The permanent fire lane shall consist of asphalt or concrete and shall be required to support 40 tons 4. The fire lane shall be platted as an “Emergency Access Easement” on the final plat. 1997 UFC 901.2.2.1; 901.3; 901.4.2; FCLUC; PFA Policy 85-5 (B) Active 1 Michael Chavez 12/18/2003 4 General [12/18/03] ADDRESS NUMERALS: Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6 inch numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). NOTE: If addressed off 1113 W. Plum St., an addressing pattern that coincides with existing buildings shall be maintained. 1997 UFC 901.4.4 Active 1 Michael Chavez 12/18/2003 5 General [12/18/03] WATER SUPPLY: Commercial No commercial building can be greater then 300 feet from a fire hydrant. Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must be capable of delivering 1500 gallons of water per minute at a residual pressure of 20 psi. 1997 UFC 901.2.2.2 Active 1 Michael Chavez 12/18/2003 6 General [12/18/03] SPRINKLER REQUIREMENTS: Buildings that are three or more stories in height shall be fire sprinklered. There shall be a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. 1997 UFC 1003.2.9; 902.2.1 Active 1 Michael Chavez 12/18/2003 7 General [12/18/03] FIRE ALARM REQUIREMENTS: A fire alarm system is required for this proposed project. 1997 UFC 1007.2.9.1.1 Active 1 Michael Chavez 12/18/2003 3/7/2011 Page 17 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 8 General [12/18/03] KNOX BOX: Poudre Fire Authority requires a “Knox Box” to be mounted on the front of every new building equipped with a required fire sprinkler system or fire alarm system. 1997 UFC 902.4; PFA POLICY 88-20 Active 1 Michael Chavez 12/18/2003 9 Zoning [7/6/04] [4/28/04] 7-7-04 - comment still applies [12/19/03] The tree cut-outs don't count as landscape dislands and don't break up the parking aisles into 15 or fewer spaces in a row. Please review - also it creates 2 non-conforming spaces that are too short - but people will still attempt to park in them - but not be able to pull all the way forward. Resolved 1 Jenny Nuckols 12/19/2003 10 Zoning [4/28/04] [12/19/03] North end parking aisle shows 16 spaces, southe nd shows 17, only 15 in a row without an intervening island are allowed Active 1 Jenny Nuckols 12/19/2003 11 Zoning [12/19/03] Would prefer the site plan to only show site itmes, not landscape items - the landscaping is/should be shown on the landscape plan Resolved 1 Jenny Nuckols 12/19/2003 12 Zoning [4/28/04] [12/19/03] Plant Notes #4 - add ot working - value of landscpaing "and installation" Resolved 1 Jenny Nuckols 12/19/2003 13 Zoning [12/19/03] On the south end where the diamond cut-out for the tree is located there is only 2.5 ft og sidewalk - check with engineering on their standards Resolved 1 Jenny Nuckols 12/19/2003 14 Zoning [7/6/04] Same comment [12/19/03] Label building envelope, footprint, dimensions, distance to property lines Active 1 Jenny Nuckols 12/19/2003 15 General [12/23/03] Project title needs to be consistent between the plan sets. All sets should read "Cambridge House Lofts" or whatever the project title is that you decide on. Resolved 1 Susan Joy 12/23/2003 3/7/2011 Page 18 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 16 Existing Site Plan [12/23/03] Remove landscaping. Resolved 1 Susan Joy 12/23/2003 17 Existing Site Plan [12/23/03] See appendix E6 for scanability requirements. Correct all overlapping labeling and increase the font size to meet the minimum. Resolved 1 Susan Joy 12/23/2003 18 Existing Site Plan [12/23/03] Sidewalk is shown between the two driveway entrances on Plum but no sidewalk to the east and west of those same drives. Is there any existing out there? If so, please show. If not, why not? Resolved 1 Susan Joy 12/23/2003 19 Existing Site Plan [12/23/03] Dimension Scott Avenue ROW, both existing and proposed. Resolved 1 Susan Joy 12/23/2003 20 Site Plan [12/23/03] Show all easements, label and dimension. Resolved 1 Susan Joy 12/23/2003 21 Site Plan [12/23/03] Remove landscaping. Resolved 1 Susan Joy 12/23/2003 22 Site Plan [12/23/03] Remove contours. Resolved 1 Susan Joy 12/23/2003 23 Site Plan [5/10/04] Repeat comment. The site plan is not scannable and will not be approved until it meets the criteria set forth in appendix E6. The font is so small in some places that I cannot read it or review it. More comments could follow when it becomes legible. [12/23/03] Correct all overlapping labeling and increase font size to meet the minimum requirement. See appendix E6 for additional scanability requirements. Resolved 1 Susan Joy 12/23/2003 24 Site Plan [12/23/03] Dimension Scott Avenue ROW, existing and proposed. Resolved 1 Susan Joy 12/23/2003 25 Site Plan [12/23/03] Please contact Tom Reiff in Transportation Planning regarding the sidewalk along Plum street east and west of the existing drive entrances as well as the sidewalk along the southern property boundary. The proposed tree well narrows the 6' sidewalk down to 2.5' and does not meet our minimum standards. Resolved 1 Susan Joy 12/23/2003 3/7/2011 Page 19 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 26 Landscape Plan [7/13/04] Please correct the easement along Plum to be a 24' Public Access and Utility Easement (see utility and plat plans) and show the emergency access easement. [5/10/04] Repeat comment. [12/23/03] Show all utilities and easements (dimensioned and labeled). Active 1 Susan Joy 12/23/2003 27 Landscape Plan [12/23/03] Remove contours. Resolved 1 Susan Joy 12/23/2003 28 Landscape Plan [5/10/04] Repeat comment. The landscape plan will not be approved until all requirements in Appendix E6 have been met. [12/23/03] See appendix E6 for scanability requirements. Resolved 1 Susan Joy 12/23/2003 29 Plat [5/10/04] Repeat comment. Corrections required, see redlines. [12/23/03] Most of the plat language shown is incorrect. Please see the attached for the correct plat language. Resolved 1 Susan Joy 12/23/2003 30 Plat [12/23/03] Spell out all abbreviated easement labels. Resolved 1 Susan Joy 12/23/2003 31 Plat [5/10/04] Repeat comment. Labeled incorrectly. [12/23/03] Change the "Pedestrian Access Easement" along Plum Street to read "Public Access Easement". Resolved 1 Susan Joy 12/23/2003 32 Plat [5/10/04] Repeat comment. Labeled incorrectly and missing width dimensions. Also, the emergency access lane is shown extending into the parking stalls and over the curb on the utility plans. This, for obvious reasons, will not work. Please locate the emergency access lanes out of these areas and in an area free of all obstructions. [12/23/03] Dedicate the fire lane on the plat, label as "Emergency Access Easement". Resolved 1 Susan Joy 12/23/2003 33 Plat [5/18/04] [12/23/03] Provide two ties to aliquot corners. Resolved 1 Susan Joy 12/23/2003 34 Utility Plans [12/23/03] Correct the preamble title to read "Utility Plans for …" Resolved 1 Susan Joy 12/23/2003 3/7/2011 Page 20 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 35 Utility Plans [5/10/04] Correction required, see redlines. [12/23/03] Provide two project bench marks referencing the City's datum. Resolved 1 Susan Joy 12/23/2003 36 Utility Plans [12/23/03] See Bob Zakely for revegatation methods and specific notes required on the plans. Resolved 1 Susan Joy 12/23/2003 37 Utility Plans [5/10/04] Because you've added a horizontal control sheet, you can put all the dimensioning on there and just show the emergency access easement on all the other sheets (it should help keep your sheets legible). Make sure that the EAE is located in an area free of all obstructions (parking stalls, curb and gutter, etc). [12/23/03] Show, dimension, and label the fire lane required by PFA. Resolved 1 Susan Joy 12/23/2003 38 Utility Plans [12/23/03] See the attached checklist for other comments. The highlighted items were reviewed with the first round of review. The remaining items are reviewed after hearing and in the final compliance review. Resolved 1 Susan Joy 12/23/2003 39 Utility Plans [12/23/03] Sheet 3, Add the street cut note: Limits of street cut are approximate. Final limits are to be determined in the field by the City Engineering Inspector. All repairs to be in accordance with City street repair standards. Resolved 1 Susan Joy 12/23/2003 40 Utility Plans [12/23/03] Provide details: 701, 702, 707, 1601, 1602, 1606 Resolved 1 Susan Joy 12/23/2003 3/7/2011 Page 21 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 41 General [5/18/04] It was agreed that a Public Access Easement would be dedicated to the back of walk in lieu of dedicating the additional ROW at this time. Please dedicate this easement on the plat. [12/23/03] This project is responsible for dedicating their half of the current local street width (51' total) and for the design and construction of Scott Avenue. There is currently 20' of ROW for Scott Avenue. That means that this project needs to dedicate an additional 15.5', or (51-20)/2. However, you may dedicate the additional width as a Public Access, Utility, and Drainage Easement instead so that the applicant still retains the currect use of the property as currently shown. In addition, this project is responsible for dedicating their half of a minor collector with parking along Plum. There is currently 40' of ROW and a total of 76' is needed. That means that this project must dedicate an additional 18' of ROW on Plum. They do NOT need to dedicate the utility easement along Plum. No additional ROW along Shields is required. Resolved 1 Susan Joy 12/23/2003 42 Tree Preservation Standards [12/29/03] Contact Tim Buchanan, City Forester for an evaluation of existing trees to be removed. If trees are being mitigated then mitigation trees need to be shown and labeled on landscape plan. Limits of development (LOD), details showing protective fencing and tree protection notes are also needed in utility set. Notes may be obtained from the City Forester. L.U.C. 3.2.1(F), 3.2.1(G) Active 1 Doug Moore 12/29/2003 43 General [12/29/03] Lighting Plan needed. Recommend that ground access to stairwells be well lit, avoid landscape materials that provide concealment, provide openings - viewports - in stairwell design. Need specific type and location of plant materials. Active 1 Joseph Gerdom 12/29/2003 3/7/2011 Page 22 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 44 General [12/30/03] Parking stall dimensions must be in accordance with LCUASS, figure 19-7. I've included a comment from the modification submittal that came through in September of 2003: [9/25/03] Upon submittal of a PDP, parking stall dimensions must meet the minimum standards as shown in Chapter 19 of LCUASS. Please label and dimension all drive aisle widths as well as all parking stall lengths and widths so that we can determine whether or not the parking stalls meet minimum requirements. 12/31/3: A variance request must be submitted in accordance with LCUASS if the parking dimensions do not meet standards. Resolved 1 Susan Joy 12/30/2003 45 General [12/30/03] Use a tapping saddle to make the fire line connection to the existing water main. Label fire line as Ductile Iron Pipe (D.I.P.). Resolved 1 Jeff Hill 12/30/2003 46 General [12/30/03] Separate water and sewer services are required for each use (i.e. commercial verses residential). Resolved 1 Jeff Hill 12/30/2003 47 General [5/20/04] Curb stops must be with in a utility easement and the meter pit may not be located more than 2 feet from the curb stop. Provide flow calculation for the sizing of the proposed water service for the residential portion of this development. [12/30/03] Curb stop and meter pit may not be located in the sidewalk or any other traveled way. See site, landscape and utility plans for other comments. Resolved 1 Jeff Hill 12/30/2003 48 General [12/30/03] Provide a 10 foot utility easement on either side of the existing sanitary sewer main. Maintain 10 foot clear separation between the existing sanitary sewer main and any permanent structure (i.e. trash enclosure, canopies, etc.). Will existing sanitary sewer manhole covers need to be raised or lowered? If so, provide all detail necessary.) Provide a water tight manhole cover for the existing manhole which will be located in the proposed curb and gutter. Resolved 1 Jeff Hill 12/30/2003 49 General [12/30/03] Maintain the required landscape/utility separation distances on the landscape plans. See site, landscape and utility plans for other comments. Resolved 1 Jeff Hill 12/30/2003 3/7/2011 Page 23 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 50 General [12/31/03] A variance request will need to be submitted by a licensed engineer if the emergency access easement does not meet standards. [9/25/03] From the modification request: Upon submittal of a PDP, the fire lane must meet the minimum requirements as shown in 7.8 of LCUASS and the Emergency Access section 3.6.6 in the COFC Land Use Code. Such emergency access lanes must be in a dedicated emergency access easement (can be done by separate document). Please contact PFA to determine if such easements are required. Please label and dimension the width and inner/outer radii of the emergency access lane so that we can determine whether or not the lane meets minimum requirements. Resolved 1 Susan Joy 12/31/2003 51 Traffic Study [12/31/03] Please provide a copy of the TIS as one was not received by the Engineering Dept. with this submittal. Resolved 1 Susan Joy 12/31/2003 52 Landscape Plan [12/18/03] The tree cut-outs don't count as landscaped islands and son't break up the parking into rows of 15 or fewer spaces Active 1 Jenny Nuckols 12/31/2003 53 General [12/31/03] No comments. Active 1 Garold Smith 12/31/2003 54 Traffic Study [12/15/03] The TIS dated 12/08/03 is acceptable. No issues from Traffic Operations Active 1 Eric Bracke 12/31/2003 55 Drainage Stormwater is ready for hearing. Additional comments may follow during final plan submittal. Resolved 1 Wes Lamarque 01/01/2004 56 Drainage Please coordinate the landscape plan with the utility plans. Shrubs are proposed over the concrete pan. Resolved 1 Wes Lamarque 01/01/2004 57 Erosion/Sediment Control 1. Please provide required calculations to support plan and surety calculations at final plan review. 2. The site slopes west to east, yet there is no protection along Shields Street. What protection will be provided there to protect areas downstream? Resolved 1 Wes Lamarque 01/01/2004 3/7/2011 Page 24 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 58 General [1/8/04] The Conceptual Landscape Plan calls the project "Cambridge House PUD." The Existing Site Plan and the proposed Site Plan calls the project "Cambridge Lofts." The elevation sheet calls the project "Cambridge House Lofts." All sheets need to use the same name. Also, the project is a Project Development Plan, not a PUD. We have therefore entered the name in our system as "Cambridge Lofts Apartments PDP." Please change the title of all drawing sets, including civil engineering drawings to this name. If you don't like the name we chose, you can choose a different one. Let us know what you want the name to be and make sure all the drawing sheets say the new name. Active 1 Troy Jones 01/08/2004 59 Plat [1/8/04] The plat is not a minor subdivision. We don't do minor subdivisions anymore. The plat should also be titled "Cambridge Lofts Apartments PDP." Active 1 Troy Jones 01/08/2004 60 General [1/8/04] Shrubs are shown within an area shown on the utility plans to be a concrete channel at the southeast corner of the site. Please resolve this conflict. Active 1 Troy Jones 01/08/2004 61 General [1/8/04] Don't show any trees on the site plan, only show them on the landscape plan. This includes not showing existing trees. Active 1 Troy Jones 01/08/2004 62 General [1/8/04] Advance Planning, Current Planning and Transportation Planning all need to review a detail at a larger scale fo the sidewalk and landscape areas on the east and south sides of the new Shields Street building. As currently shown, it's just too small of a scale to get an understanding of what's exactly proposed. It's not clear what's proposed within the planting beds, and the paving patterns are a little confusing at this scale. Active 1 Troy Jones 01/08/2004 63 General [1/8/04] Along the northeastern corner of the site, extend a sidewalk along the street frontage. If the existing tree is in the way, it can be removed, because it is considered a nusiance species of tree. Tim Buchanan, the City Forester should be contacted first. Active 1 Troy Jones 01/08/2004 64 General [1/8/04] The new tree porposed along the south property line midway between the new building and the existing apartments is not considered to be feasible to have there because of the location of the sewer line in that vicinity. You should remove this tree from the plans. The landscape diamond should remain where shown, but have a shrub. Active 1 Troy Jones 01/08/2004 3/7/2011 Page 25 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 65 General [1/8/04] Scott Avenue is a public street directly west of the site. It is gravel and the right of way is only 25 feet wide. At some point in the long mid to long term future, Scott Avenue will likely be widened and improved by the creation of some sort of Special Improvement District or some other mechanism. Although such improvements would not likely happen anytime soon, such widening would impact the parking along the west edge of Cambridge House Apartments. If Scott Avenue were to have a right of way width in accordance with the local residential street standard, the right of way would need to be 51 feet wide. This would mean that an addition 15.5 feet would be needed from the Cambridge House apartments property to accomplish this. One potential solution staff is considering would be to have this project dedicate a 15.5 foot wide access easement along the western edge of the property. The conditions by which the City would exercise the use of this area would need to be carfully spelled out in the development agreement. It would also need to be clarified in the developent agreement that the loss of on-site parking as a result of Scott Street being built would need to be somehow accommodated by on-street parking, or some other solution that doesn't adversely affect Cambridge House Apartment. I'm in the process of coordinate schedules, we should meet on this issue next week. Active 1 Troy Jones 01/08/2004 66 General [1/8/04] The scale on the conceptual landscape plan and the site plan seems to be the same but one is labeled at 1"=20' and the other is labeled at 1"=30'. Please clarify. Active 1 Troy Jones 01/08/2004 67 General [1/8/04] Specify colors of materials on the elevations and bring in samples of the brick and concrete block. Active 1 Troy Jones 01/08/2004 68 General [1/8/04] We can tentatively plan to take the project to the Feburary 19th Planning and Zoning Board meeting, provided we come to an agreement on how best to deal with Scott Avenue. Active 1 Troy Jones 01/08/2004 69 General [1/8/04] OK. Active 1 Beth Sowder 01/08/2004 70 General [1/8/04] No comment. Active 1 Craig Foreman 01/08/2004 71 General [1/8/04] No Concerns. Active 1 Carl Jenkins 01/08/2004 3/7/2011 Page 26 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 72 General [1/8/04] Any relocation, cutoff's or installation of gas facilities will be at developers expense. Active 1 Len Hilderbrand 01/08/2004 73 General [1/8/04] No trees planted with in 4' of gas lines. (existing or future mains, services, etc.) Active 1 Len Hilderbrand 01/08/2004 74 General [1/8/04] Plat shows wrong legals for area/ 67W Should be/ 15. 7N. 69W Active 1 Len Hilderbrand 01/08/2004 75 General [1/8/04] Water Conservation has no comments. Active 1 Troy Jones 01/08/2004 76 General [1/8/04] See the attached comment sheet from Building Inspection. Active 1 Troy Jones 01/08/2004 77 Plat [1/9/04] All of the plat language is wrong. Please see the attached for the correct language. Resolved 1 Susan Joy 01/09/2004 78 Plat [1/9/04] Correct the project title. Resolved 1 Susan Joy 01/09/2004 79 Plat [1/9/04] Spell out all abbreviations. Resolved 1 Susan Joy 01/09/2004 80 Plat [1/9/04] Dedicate the emergency access lane required by PFA. Resolved 1 Susan Joy 01/09/2004 81 Plat [1/9/04] See comments under General that effect the plat. See redlines. Resolved 1 Susan Joy 01/09/2004 82 General [1/9/04] See attached redlines from Current Planning. Active 1 Troy Jones 01/09/2004 83 General [1/9/04] The sidewalk along the south side of the new building must be a minimum of 6 feet wide [LUC 3.2.2(C)(5)]. Active 1 Troy Jones 01/09/2004 84 Transportation [7/13/04] The additional ramps along the walkway connecting Shields St. to the existing Cambridge House apartment complex are still not shown on the utility plans. Please correct. [5/18/04] A few additional access ramps still need to be added to the plans (see red lines). [1/12/04] Please include all access ramps associated with sidewalks on all the plan sets including the utility and site plans. Active 1 Tom Reiff 01/12/2004 3/7/2011 Page 27 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 85 Transportation [5/18/04] [1/12/04] Plum Street is classified as a collector on the Master Street Plan. Please dedicate your half of the 76 foot right of way. This should be measured from the centerline of Plum Street. Resolved 1 Tom Reiff 01/12/2004 86 Transportation [5/18/04] Please remove the proposed new vertical v-shaped curbs shown on the utility plans along the Scott R.O.W. These verical curbs were intended for landscaping that is not longer required. [1/12/04] Given the planned future connection of Scott Avenue to W. Elizabeth, please replace the proposed shade trees along Scott Avenue with ornamental trees. Resolved 1 Tom Reiff 01/12/2004 87 Transportation [7/13/04] Utilitiy plans need to clearing show how the sidewalks changes along Plum Street will connect to the existing sidewalk. [5/18/04] There are minor discrepancies between the utility plans and the site and landscape plans. Please clean up the Plum Street sidewalk configuration between the plan sets. Keep in mind that the sidewalk needs to continue to the edge of the property line and connect to the existing sidewalk. [1/12/04] The sidewalk along Plum Street will need to continue to the edge of the property line to the east. Please include a sidewalk that crosses the driveway to the eastern property line (see red lines for alignment). Active 1 Tom Reiff 01/12/2004 88 Transportation [1/12/04] Please provide an enlarged section for the Shields Street sidewalk and landscaped frontage. Also the sidewalk on the south side of the building should be a minimum of 6 feet in width to accommodate the high pedestrian traffic. Resolved 1 Tom Reiff 01/12/2004 89 Zoning [4/28/04] Please remove the small print referencing landscaping on the site plan. Does not need to be on site plan and is too small to read anyway. Active 2 Jenny Nuckols 04/28/2004 90 Site Plan [7/13/04] Please correct the easement along Plum to be a 24' Public Access and Utility Easement (see utility and plat plans). [5/10/04] Site plan does not match the utility plans. Active 2 Susan Joy 05/10/2004 3/7/2011 Page 28 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 91 Landscape Plan [5/10/04] The landscape plan does not match the utility plan. Resolved 2 Susan Joy 05/10/2004 92 Utility Plans [7/14/04] Correction required to the emergency access easement variance. The min widths and radii were not met at the "pinch" point and it needs to be reworded to reflect that. [5/10/04] Sheet 2 - please be a little more specific on the variance granted in line 48. Include the section, the actual requirement, and then the variance itself. Also, include the variance to the emergency access easement miminum widths and radii granted by PFA. Active 2 Susan Joy 05/10/2004 93 Utility Plans [5/10/04] Sheet 3 - Label all easements with what the easement is for (Utility, Emergency Access Easement, etc). Resolved 2 Susan Joy 05/10/2004 94 Utility Plans [5/10/04] Sheet 3 - Correct all overlapped labeling. Remove the landscaping. Resolved 2 Susan Joy 05/10/2004 95 Utility Plans [5/10/04] Sheet 4 - is unscannable. Remove landscaping. Resolved 2 Susan Joy 05/10/2004 96 Landscape Plan [5/10/04] Planters along Shields street must be located outside the existing utility easement or are these tree grates? Please label accordingly. Resolved 2 Susan Joy 05/10/2004 97 Utility Plans [5/10/04] Sheet 5 - Remove the landscaping. Block out background around text. Correct a misspelled word. Resolved 2 Susan Joy 05/10/2004 98 Utility Plans [5/10/04] Cover Sheet - Please provide the name, address, and phone number of the Owner and/or Developer. Resolved 2 Susan Joy 05/10/2004 99 Utility Plans [5/10/04] Sheet 4 - Please provide finish grade elevations for all lot corners and finish floors/top of foundation of all buildings for all lots. Resolved 2 Susan Joy 05/10/2004 100 Utility Plans [5/10/04] Sheet 4 - Please provide the statement: The top of foundation elevations shown are the mimimum elevations required for protection from the 100-year storm. Resolved 2 Susan Joy 05/10/2004 101 Utility Plans Please provide site specific details for the sidewalk chase and concrete channel. See redlined plans. Also, provide a valley pan detail. Resolved 2 Wes Lamarque 05/17/2004 102 Utility Plans Please provide a F.F. elevation for the proposed building. Resolved 2 Wes Lamarque 05/17/2004 3/7/2011 Page 29 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 103 Utility Plans 1. Please provide a project schedule indicating when various BMP’s will be installed within the framework of the construction. You don’t need to use specific dates (months), you can just use project phases, etc. Resolved 2 Wes Lamarque 05/17/2004 104 Utility Plans [5/18/04] Parking lot lighting levels are below required 1.0fc. Also, important in making revisions - evaluate location of plant materials. Need photometrics for area next to stairs. Active 2 Joseph Gerdom 05/18/2004 106 Plat [5/18/04] Instead of having a 15' utility easement and 24' public access easement along Plum, just make one combined 24' Public Access and Utility Easement. Resolved 2 Susan Joy 05/18/2004 108 Plat [5/18/04] Label Scott Avenue as 25' ROW. Resolved 2 Susan Joy 05/18/2004 109 Plat [7/13/04] [5/18/04] From Technical Services: Boundary and legal close. Active 2 Susan Joy 05/18/2004 110 Plat [5/18/04] From Technical Services: The need for a block in a 2 lot subdivision is unnecessary. Resolved 2 Susan Joy 05/18/2004 111 Plat [7/14/04] [5/21/04] Will there be any restaurants in the building? If so, provide grease interceptor. Active 2 Roger Buffington 05/21/2004 112 Landscape Plan [5/24/04] The (Final Compliance) Landscape Plan does not necessarily satisfy the City Forester's requirement for tree mitigation for the loss of 4 existing significant trees. Based on the previous Landscape Plan, Tim Buchanan stated that 12 new trees need to be upsized to 3.0" caliper for adequate mitigation. The current plan shows 7 new deciduous trees to be upsized to 3.0" caliper and 5 new ornamental trees to be upsized to 2.5" caliper. Mr. Buchanan must determine if the current plan satisfies the Land Use Code requirement for tree mitigation. Active 2 Steve Olt 05/24/2004 113 Landscape Plan [5/24/04] The proposed "Fallgold" Ash at the northwest corner of the site is too close to the west edge of the driveway into the development. It must be a minimum of 8' from edge of driveway. The "Fallgold" Ash is not shown in the Plant Legend. Also, this proposed tree may be in conflict with a future Scott Avenue entension. Active 2 Steve Olt 05/24/2004 3/7/2011 Page 30 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 114 Landscape Plan [5/24/04] There are 3 Ash trees shown in the planting island just west of the existing church. The assumption is that they are to be "Summit" Ash and should be labeled as such on the plan. Active 2 Steve Olt 05/24/2004 115 Landscape Plan [5/24/04] Plan Note #4 must be revised to include the reference to 125% of the "materials & labor" for the landscaping. Active 2 Steve Olt 05/24/2004 116 Landscape Plan [5/24/04] It is difficult to follow the alignment of the existing (proposed?) sidewalk along the south side of West Plum Street, north of the 3 buildings in this development. Active 2 Steve Olt 05/24/2004 117 Landscape Plan [5/24/04] Please add a scale on this sheet for the Full Landscape Plan. It should be, presumably, 1" = 30.0'. Active 2 Steve Olt 05/24/2004 118 Site Plan [5/24/04] On the Site Plan, eliminate the labeling for plant material around the new building. The plant material is not shown but the labeling still is. Active 2 Steve Olt 05/24/2004 119 Site Plan [5/24/04] Under the Land Use Statistics on the Site Plan, the Maximum Building Height is shown to be 56'-0". This is inconsistent with the Exterior Elevations Plan, which shows the building to be 58'-0" high. Active 2 Steve Olt 05/24/2004 120 Building Elevations [5/24/04] The Exterior Elevations Plan shows the building to be 58'-0" high. This is inconsistent with the Site Plan, which indicates a Maximum Building Height of 56'-0" under the Land Use Statistics. Active 2 Steve Olt 05/24/2004 121 Site Plan [5/24/04] The Planning & Zoning Certificate block is not needed on the Site Plan and should be removed. Active 2 Steve Olt 05/24/2004 122 Site Plan [5/25/04] There are numerous words misspelled in the General Notes on the Site Plan (please see red-lined plan). Active 2 Steve Olt 05/25/2004 123 Plat [7/13/04] Repeat from last round of redlines: What are all the extra leaders for? Active 3 Susan Joy 07/13/2004 124 Plat [7/13/04] From Technical Services: Typo in Legal, section 12 should be section 15 (see redlines). Active 3 Susan Joy 07/13/2004 125 General [7/13/04] Ready for mylars with the remaining items addressed (do not need to resubmit). Active 3 Susan Joy 07/13/2004 3/7/2011 Page 31 Project: CAMBRIDGE LOFTS APARTMENTS PDP & FC - TYPE I (LUC) ID Topic Issue Status Round Comment By Initial Date 126 Drainage The F.F. elevation for the building needs to be 18-inches above the flowline of the gutter in Shields. This is required due to the flow depth allowed in an arterial street to be 18-inches in the 100-year storm. Resolved 3 Wes Lamarque 07/13/2004 127 Drainage Please change detail of 5-foot chase to have a 6-inch concrete support. See redlined plans. Resolved 3 Wes Lamarque 07/13/2004 128 Utility Plans [7/14/04] Check labeling of water services. A 1" water service is not adequate for 12 units. Active 3 Roger Buffington 07/14/2004 129 General [7/14/04] No issues. Active 3 Doug Moore 07/14/2004 130 General [7/21/04] The Current Planning Department is ready for mylars of the Site Plan, Landscape Plan, Building Elevations, and subdivision plat (3 sets, at least 1 with original signatures) to be submitted. Active 3 Steve Olt 07/21/2004 3/7/2011 Page 32