Loading...
HomeMy WebLinkAboutCAMBRIDGE HOUSE APARTMENTS , MODIFICATION OF STANDARDS - 06-03B - CORRESPONDENCE -Project: CAMBRIDGE HOUSE APARTMENTS, MODIFICATION OF STANDARDS - TYPE II (LUC) Modification of Standards REQUEST FOR A MODIFICATION TO SECTION 3.2.2(K)(1)(a) OF THE LAND USE CODE FOR PARKING STANDARDS Project Type: Project Desc: File ID: 06-03B Planner: DMS Project Num: CP031444 ID Topic Issue Status Round Comment By Initial Date 1 zoning [9/25/03] Upon submittal of a PDP, please show typical stall dimension for standard and compact spaces, as well as HC. NOTE - one HC space must be van accessible. Active 1 Jenny Nuckols 09/25/2003 2 zoning [9/25/03] I only see 4 HC spaces called on the plan - the description states that there are 6. Upon submittal of a PDP, please clarify. Active 1 Jenny Nuckols 09/25/2003 3 zoning [9/25/03] Upon submittal of a PDP, compact parking spaces need signage indicating that they are for compact only Active 1 Jenny Nuckols 09/25/2003 4 zoning [9/25/03] Doesn't meet parking aisle requirement of no more than 15 spaces without and intervening landscaped island. Upon submittal of a PDP, zoning will want to be involved in the discussion of how this meets the requirement to the extent reasonably feasible. Resolved 1 Jenny Nuckols 09/25/2003 5 Parking [9/25/03] Upon submittal of a PDP, parking stall dimensions must meet the minimum standards as shown in Chapter 19 of LCUASS. Please label and dimension all drive aisle widths as well as all parking stall lengths and widths so that we can determine whether or not the parking stalls meet minimum requirements. Active 1 Susan Joy 09/30/2003 6 Fire Lane [9/25/03] Upon submittal of a PDP, the fire lane must meet the minimum requirements as shown in 7.8 of LCUASS and the Emergency Access section 3.6.6 in the COFC Land Use Code. Such emergency access lanes must be in a dedicated emergency access easement (can be done by separate document). Please contact PFA to determine if such easements are required. Please label and dimension the width and inner/outer radii of the emergency access lane so that we can determine whether or not the lane meets minimum requirements. Active 1 Susan Joy 09/30/2003 7 General No comments regarding the parking modification. Active 1 Tom Reiff 10/13/2003 3/7/2011 Page 1 Project: CAMBRIDGE HOUSE APARTMENTS, MODIFICATION OF STANDARDS - TYPE II (LUC) ID Topic Issue Status Round Comment By Initial Date 8 General [10/17/03] The Planning and Zoning Board approved the proposed "Alternative A" modification request on October 16, 2003 by a vote of 5 to 1. "Alternative A" proposed to provide a minimum of 170 parking spaces to sereve a future PDP for 18 new dwelling units, and 1,900 square feet of non-residential space. In order for the modification to be utilized, A PDP must be submitted within 1 year of the approval of the modification for 6 two-bedroom dwelling units as part of a conversion of the existing pool house, and 12 three-bedroom dwelling units in a new mixed use building adjacent to Shields street. Such mixed use building must contain approximately 1,900 square feet of non-residential uses along the street facing ground floor of the building. The site layout must of the PDP must be in substantial compliance with the site plan that was shown to the Planning and Zoning Board for "Alternative A" at the hearing in which it was approved. Active 1 Troy Jones 10/17/2003 9 General [12/16/03] No comments Active 1 Garold Smith 12/16/2003 10 zoning [12/18/03] The tree cut-outs don't count as landscaped islands and son't break up the parking into rows of 15 or fewer spaces Active 1 Jenny Nuckols 12/18/2003 3/7/2011 Page 2